Application for Amend to Licenses NPF-4 & NPF-7,revising Tech Specs Re Waste Gas Charcoal Filter Sys,Control Room Habitability Sys & Safeguards Area Ventilation Sys.Fee Paid
ML20112D474
Person / Time
Site: North Anna  
Issue date: 01/08/1985
From: Stewart W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To: Harold Denton, John Miller
Office of Nuclear Reactor Regulation
Shared Package
ML20112D476 List:
References
188, NUDOCS 8501140313
Download: ML20112D474 (4)


Text

_ _____-

VINGINIA ELucTHIc AND Powen COMPm Ric11xoxo, VIRG INIA 2 0 2 61 W.L.Srawaar vic v...in==v January 8, 1985 Nt:cz. san ormeArrown Mr. Harold R. Denton, Director Serial No. 188 Office of Nuclear Reactor Regulation N0/JHL:acm Attn:

Mr. James R. Miller, Chief Docket Nos. 50-338 Operating Reactors Branch No. 3 50-339 Division of Licensing License Nos. NPF-4 U. S. Nuclear Regulatory Commission NPF-7 Washington, D. C. 20555 Gentlemen:

VIRGINIA ELECTRIC AND POWER COMPANY NORTH ANNA POWER STATION UNIT NOS. 1 AND 2 PROPOSED TECHNICAL SPECIFICATION CHANGES Pursuant to 10 CFR 50.90, the Virginia Electric and Power Company requests an amendment in the form of a change to the Technical Specifications, to Operating Licenses NPF-4 and NPF-7 for North Anna Power Station Unit Nos. I and 2.

The proposed changes will revise Technical Specifications 4.6.4.3, 4.7.7.1 and 4.7.8.1 which relate to the Waste Gas Charcoal Filter System, Control Room Emergency Habitability Systems and Safeguards Area Ventilation System.

Specifically, the changes in these sections will revise the laboratory testing of used charcoal samples to come into conformance with ASTM D 3803-79 which will yield more accurate and repeatable results.

The proposed changes will not change the acceptance criteria for the removal efficiency of used charcoal samples. The proposed Technical Specification changes for North Anna Unit No.

I are provided in Attachment 1.

The proposed Technical Specification changes for North Anna Unit No. 2 are provided in Attachment 2.

A discussion of the proposed Technical Specification changes is provided in Attachment 3.

This request has been reviewed and approved by the Station Nuclear Safety and Operating Committee and the Safety Evaluation and Control Staff.

It has been determined that this request does not involve an unreviewed safety question as defined in 10 CFR 50.59.

It has been determined that th'e proposed changes do not pose a significant hazards consideration as defined in the Federal Register, dated April 6, 1983, Page 14870; a change to make a license conform to changes in the regulations, where the license change results in very minor changes to facility operations clearly in keeping with the regulatione.

The proposed changes will clarify the method of testing of HEPA filters and charcoal adsorbers and they will not change the acceptance criteria for the removal efficiency of the used charcoal

\\

samples.

k 8501140313 850108 3

PDR ADOCK 05000338 P

PDR

},

c g.g

(.

s VamonwA Ex.zcTaic Awn POwma COMPANY TO We have reviewed this request in accordance with the criteria in 10 CFR-170.12.

A voucher check in the amount of $150 is enclosed as an application fee.

i Very truly yours, n.

s hs W. L. Stewart Attachments:

l 1.

Proposed Technical Specification Changes - Unit 1 2.

Proposed Technical Specification Changes - Unit 2 3.

Discussion of Proposed Technical Specification Changes 4.

Voucher Check for $150 cc:

Mr. James P. O'Reilly Regional Administrator Region II Mr. M. W. Branch NRC Resident Inspector North' Anna Power Station Mr. Charles Price Department of Health-109 Governor Street Richmond, Virginia 23219 a

1

l COMMONWEALTH OF VIRGINIA )

)

CITY OF RICHMOND

)

The foregoing document was acknowledged before me, in and for the City and Conanonwealth aforesaid, today by W.

L.

Stewart who is Vice President Nuclear Operations of the Virginia Electric and Power Company.

He is duly authorized to execute and file the foregoing document in behalf of that Company, and the statements in the document are true to the best of his knowledge and belief.

Acknowledged before me this day of Ge e

, 19 Fi.

U My Commission expires:

0 34 19 E s, l

(. Jh 'W Notary Public i

l (SEAL)

S/ool

0 0

O f

ATTACHMENT 1

)

I t

I I

-