Forwards Amend 36 to Rev 8 to 23A6100, ABWR SSAR & Rev 7 to 25A5447, Certified Design Matl
ML20101G902
Person / Time
Site: 05200001
Issue date: 03/22/1996
From: Quirk J
GENERAL ELECTRIC CO.
To: Quay T
NRC (Affiliation Not Assigned), NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20101G908 List:
References
MFN-039-96, MFN-39-96, NUDOCS 9603280189
Download: ML20101G902 (64)


Text

{{#Wiki_filter:__ {] ( ) v GENuclearEnergy Joseph F. ourt GeneralElectnc Company ABWR Licensing Manager 175 Cwtner Annue. MC 782. San Jose. CA 951251014 hojectManager ABWRCert&cahon 408 92s6219(phone) 406 9254257itacsimde) March 22,1996 MFN 039-96 Docket No. 52-001 Document Control Desk U.S. Nuclear Regulatory Commission Washington DC 20555 Attention: Theodore E. Quay, Director Standardizatior. Project Directorate

Subject:

Submittal of Amendment 36, Revision 8, to GE's ABWR SSAR and Certified Design Material, Revision 7

Reference:

Submittal of Revision 2 to the ABWR Design Control Document, MFN 004-95, January 17,1995 The purpose of Amendment 36 Revision 8 to GE's ABWR SSAR and Certified Design Material Revision 7 is to bring these documents into alignment with the ABWR Design Control Document (DCD) Revision 2 (Reference letter). The ABWR DCD Revision 2 was approved for incorporation in the proposed ABWR Design Certification Rule (60 FR17902, April 7,1995). It should be noted that the conforming changes covered by this submittal are non-substantive changes only. In accordance with direction of NRR project staff, GE is providing a total of twenty-seven (27) copies of SSAR Amendment 36 Revision 8 and CDM Revision 7 to the specified recipients listed on Attachment 1. This includes ten (10) copies being sent herewith to the Document Control Desk. This is being done to accelerate the distribution process and ensure timely staff receipt of this information. SSAR Amendment 36 Revision 8 and CDM Revision 7 incorporate Attachment 2 which summarizes the actions taken to align the CDM and the SSAR with the approved DCD Revision 2. 2S(f62 0 kyb \\\\0 %eh Q 9603200189 960322 PDR ADOCK 05200001 t A PDR

I U . superszes Attachment 3 of the Reference letter which provided a list of differences between the DCD and the CDM/SSAR. The actions indicated in Attachment 2 as "DCD only" or those entries that indicate a partial alignment (e.g/ Section 1.6-1 showing "Updrae title only in SSAR"), reflect the intended differences between the DCD and the CDM/SSAR. In other words, both SSAR Amendment 36 Revision'8 and CDM Revision 7 are identical to the approved DCD Revision 2 except in those areas in which the differences are intentional (e.g. Severe Accident /PRA, Tier 2* information, proprietary information, safeguards information). Page change instmetions for CDM Revision 7 are provided in Attachment 3 and for ABWR SSAR Revision 8 in Attachment 4. Sincerely, ).. Quirk Project Manager ABWR Certification MC-782, (408) 925-6219 cc: (w/o attachments) S.A. Hucik (GE) W.T. Russell (NRC) F.J. Miraglia (NRC) T. H. Boyce (NRC) D. M. Crutchfield (NRC) S. M. Franks (DOE) F. A. Ross (DOE) N.D. Fletcher (DOE) T.J. Mulford (EPRI)

s. GE Nuclear Energy letter dated March 22, 1996 (MFN 039096). Distribution of enclosures to the following branches: LTR ENCL NRR/DRPM/PDST 1 1 PM - BOYCE, T. 1 1 FILE CENTER 01 1 1 NRR/DE/EMCB 1 1 NRR/DE/EMEB 1 1 s NRR/DRPM/PDLR 1 1 NRR/DSSA/SCSB 1 1 OGC/HDS3 1 1 RES/DE/SSEB 1 1 RES/DSIR/SAIB 1 1 NRC PDR 1 1 11 11 4

__ ~_ A'ITACHMENT 1 DIRECT SHIPMENT OF SSAR AMENDMENT 36, REVISION 8 AND CDM REVISION 7 Mall Stop Individual Orennlintian O-7H15 G. Bagchi(2 copies) NRR/ADT/DE/ECGB O-8H7 C.H. Berlinger NRR/ADT/DSSA/SCSB O-9D24 L.J. Cunningham NRR/DRPM/PSGB O-11E22 C. I. Grimes NRR/ADPR/TSB O-10E4 E.J. Butcher NRR/ADT/DSSA/SPSB O-8DI C.E. McCracken NRR/ADT/DSSA/SPLB O-7E4 J. A. Calvo NRR/ADT/DE/EELB O-E23 R.C. Jones NRR/ADT/DSSA/SRXB O-10D24 C.O. Thomas NRR/ADTDRCH/HHFB O-10A19 S.C. Black NRR/ADT/DRCH/HQMB O-Pl-37 Document Control Desk (10 Copies) T-2E26 M. El-Zeftawy ACRS O-11H3 T.E. Quay (2 copies) NRR/ADT/DRCH/HICB O-8H3 J.S. Wermiel NRR/ADT/DRCH/IECB O-10D4 C.L. Miller NRR/DRPM/PERB O-15B18 R.M. Weisman OGC

Alignment of CDM with DCD DCD Section/Pg Difference Action Tier i TOC v/vi Add footnote ** Section number in parenthesis - Section under which Update CDM the subject is covered. 2.2.3 pg.4 Item I column 2 was indented to match CDM DCD only 2.7.1-3,4 Changed "SGTS ( A)" to "SGTS (B)", "SGTS (B)" to "SGTS (C)", Update CDM and "FCS ( A)" to "FCS (B)", "FCS(B)" to "FCS(C)" 2.8.1-1/2 Added "to" following predicted in item i Update CDM 2.8.3-1/2 Replaced " dual" with "the" in first sentence. Added "s" to control rod Update CDM in first sentence of item (4). Added the phrase "(associated with a given accumulator)" 2.8.4-1 Added "s" to component and event in fourth paragraph. Update CDM 2.12. i- ! Insened "at least" before "a UAT or RAT" in second line of next to Update CDM last paragraph 2.12.14-1

Del,

,d "is a voltage regulating device and" in front of "the alternate Update CDM power supply" at the end of the fourth paragraph. 2.12.14-3 Removed " VOLTAGE REGULATING DEVICE" put in Update CDM " ALTERNATE POWER SUPPLY" 2.12.14-4 Item 2 First column last sentence. Third column last sentence. Update CDM Removed "is a voltage regulating device, and" 2.14.1-4 Figure was electronically cleaned up DCD only 2.14.6-5/6 Changed "7.34kg/cm'" to "0.72 Mpa" under item 8 Update CDM 2.15.5-7 Changed "45 C" to "50 C" Update CDM Figure 2.15.5j Reversed llWil inlet to outlet and llNCW outlet to inlet Update CDM 2.15.10 Figures Figures were updated electronically DCD only Figure 2.15.10h Changed RF to RE, indicated secondary containment boundary and Update CDM showed solid wall between RSS rooms Section 3.2 Figures Drawings were cleaned up DCD only CDM-1

Attrchment 2 Alignment of CDM with DCD DCD Section/Pg Difference Action 5.0-2 Changed "26.6 C" to "26.7 C" Update CDM 5.0-2 Changed "717.85kPa" to "718.20kPa" Update CDM 5.0-2 Changed " 2.35kPa" to "2.394kPa" and "13.8kPaD" to "13.827kPaD" Update CDM CDM-2 i

Alignment of SSAR with DCD DCD Section/Pg Difference Action l Tier 2 i Changed title of Section 1.6 Update SSAR ii Added title for Appendix 3K DCD only e iv Changed title for Section 14.3 DCD only Chapter 1 l.0-i Changed title of Section 1.6 Update SSAR 1.1-1 Replaced " Advanced Boiling Water Standard Safety Analysis Report" DCD only with " Tier 2" in first paragraph i 1.1-1 Replaced SSAR with " Tier 2" in second paragraph DCD only i i 1.1-3 Changed "ABWR SSAR" to " Tier 2 in beginning of Section 1.1.5 and DCD only removed " final design approval (FDA) and". 1.2-1 Removed white space DCD only i 1.2-25 Removed last sentence -Duplicate Update SSAR 1.2.2.10.1.3 1.2-26 Changed " 188.5 rad /sec" to "188.5 rad /s" Update SSAR 4 1.2.2.I1.7 1.2-27 Changed "188.5 rad /sec" to "188.5 rad /s" Update SSAR j 1.2.2. I 1. I 6 1.3-6 Item 3 in footnote - Modification to fit DCD needs DCD only l 1.6-1 Changed Title of Section and opening sentence Update title only in SSAR 1.6-2 thru Changed "SSAR" to " Tier 2" in right-hand column DCD only 1.6-6 } 1.7-1 Repixed "...the ABWR SSAR" with " Tier 2" in second line DCD only 1.7-2 Removed white space DCD only 1.7-3 Removed white space DCD only SSAR-1

Alignment of SSAR with DCD DCD Section/Pg Difference action 1.7-6 ltem (3) - Changed title to IIcat/ Energy from lleat/ Energy / Power Update SSAR 1.7-23 Changed explanation ofitem 2D Update SSAR 1.7-24 Item 3C Changed I to 0 in right hand bottom comer of table Update SSAR 1.8-12 Added appendix A to SRP No.3.5.3 Update SSAR 1.8-12, 13 Bracketed and Italicized SRP 3.5.3,3.8.1 and 4.2 Appendices and DCD only added "(l)' and "(2)" superscript 1.8-24 Added two footnotes to Table 1.8-19 DCD only 1.8-25,26 Removed white space DCD only 1.8-27 Corrected Title of Reg. Guide 1.43 Update SSAR I.8-27 Italicized 1.47 and added superscript (4) DCD only 1.8-29 Italicized 1.75 and added superscript (4) DCD only 1.8-29 Italicized 1.84 and added Superscript (1) DCD only 1.8-30 Italicized 1.89 and added superscript (2) DCD only 1.8-30 Italicized 1.92 and added superscript (1) DCD only 1.8-30 Italicized i.100 and added superscript (2) DCD only 1.8-31 Italicized 1.105 and added superscript (3) DCD only 1.8-34 Italicized 1.153 and added superscript (4) DCD only 1.8-34 Italicized 1.153 and added superscript (4) DCD only 1.8-34.1 Added notes to Table 1.8-20 DCD only 1.8-35 Changed "1983" to "1989" under 318 Update SSAR 1.8-36 - Revised title of ANSI A58.1 Update SSAR SSAR-2

Alignment of SSAR with DCD DCD Section/Pg Difference Action 1.8-39 Added ANSI X3.139, X.143, X3.166, and X3T9. 5/84-49 Update SSAR 1.8-39, 40 Added entry for ASME NQA-2a Update SSAR 1.8-41 Corrected spelling of " surge" in IEEE C62.41 entry Update SSAR 1.8-42 Added number for IEEE 7-4.3.2 Update SSAR Referenced footnote (9) under IEEE 338 and added footnote (9) to DCD only page 1.8-47 1.8-43 Added 'EEE 518 Update SSAR 1.8-44 Rc.noved IEEE 1033 Update SSAR Added IEEE 1050 1.8-45 NFPA-80A Capitalized " Building" Update SSAR 1.8-45 Removed white space DCD only 1.8-46 Removed white space DCD only Added MIL llDBK 217 Update SSAR Added ASCE71988 Update SSAR Added and italicized IEC 801-2 and referenced note (3) Add IEC 801-2 to SSAR 1.8-51 Added IE Bulletin 79-02 Update SSAR I SSAR-3

Alignment of SSAR with DCD DCD Section/Pg Difference Action 1.8-35 thru 1.8-87 Italicized and bracketed the following codes and standards: DCD only ACI 349 IEEE 830 AISC N690 IEEE 845 ANS 7-4.3.2 IEEE 1012 ANS 57.5 IEEE 1023 ANS 58.2 ANSl/flFS-100 IEEE 1042 IEEE 1050 X3.139 IEEE 1228 (Draft) X3.148 DOD 5000.2 X3.166 DOD AD/A223168 X3T9.5/84/49 DOE AR602-1 ANSI /NQA-2a DOE DI-ilFAC-80740 ASTM C776 DOE ESD-TR-86-278 ASTM C934 DOE IIDBK-76i A IEEE C37.90.2 DOE IIDBK-763 IEEE C62.41 DOE-STD-2167A IEEE C62.45 DOD TOP l-2-610 IEEE C63.12 MIL-H-46855B IEEE 279 MIL-ilDBK-217 IEEE 323 MIL-ilDBK-251 IEEE 338 MIL-fiDBK-759A IEEE 344 MIL-STD-461C IEEE 384 MIL-STD-462 IEEE 518 MIL-STD-1472D IEEE 603 MIL-STD-1478 IEEE 730 IEC 801-2 IEEE 802.2 IEC 880 IEEE 802.5 IEC 964 IEEE 828 ISO 7498 IEEE 829 I and added the corresponding nine notes to page 1.8-47. 1.9-1 Replaced "ABWR SSAR" with " Tier 2" 3 places DCD only SSAR-4 =

1 i Alignment of SSAR with DCD i DCD Section/Pg Difference Action ] 1.9-2 Removed white space DCD only ) 1.9-4 Changed item 3.8 to "Not Used" DCD only 1.9-5 Changed items 3.31-3.36 to "Not used" DCD only i 1.9-6 Changed item 8.7 to "Not Used" DCD only 1.9-7 Changed " Deleted" to "Not Used" 9 places DCD only 1.9-8 Removed white space DCD only i 1.9-9 Changed Item 9.29 to "Not Used" DCD only 4 1.9-10 Removed white space DCD only 4 1.9-10 Changed Item 14.3 to "Not Used" DCD only 1.9-10 Change Item 15.8 to "Nat Osed" DCD only l A-2, 3 Uniialicized submittal list title names and added quotes DCD only lA-5 Unitalicized " General Design Criteria" DCD only 1 j lA-11 Italicized " Plant specific models..." Added footnote DCD only j I A-19 Unitalicized " Additional information.. " added quotes DCD only I A-36, 37 Unitalicized references. Added quotes DCD only a lAA-3 Replaced "SSAR" with ' Tier 2" 2 places DCD only IAA-6 In second paragraph, replaced "0.983", with " estimated to be very high" DCD only 1 AA.4.3 IB Changed Title to "Not Used" DCD only i 1C-1 Changed italics to underline DCD only ] IC-2 Changed italics to underline DCD only i SSAR-5 m

t t Alignmcnt of SSAR with DCD DCD Section/Pg Difference Action 1 C-5/1 C.2.3.1.3 Changed "SSAR" to " Tier 2" DCD only 1C-9 Unitalicized references DCD only 1C-10 Unitalicized requirements DCD only IC-12 Unitalicized item (b) and (c) DCD only j l Chapter 2 2.0-2 Changed "2.354" to "2.394" - Max. Snowload Update SSAR Changed "717.85" to "718.20" - Static Bearing Cap. Update SSAR Changed "26.6 C" to "26.7 C"- Ambient Design Temp. Update SSAR 2.3-1 Changed "717.85" to "718.20" - Bearing Cap. Update SSAR 2.3-6 Changed "717.85" to " 718.20" - Minimum Soil Bearing Cap. Update SSAR j Chapter 3 I 3.0-iii/iv Removed listing for Att. 3AA and added title for Appendix 3K DCD only 3.1 Removed space at top of page Update SSAR 3.1-63 Third paragraph Unitalicized " Radioactive Waste Mgmt + Process DCD only Rad. Mon." j 3.2-8,9 Italicized first paragraph ofitem (3) and added footnote DCD only Italicized Item (4) (a)(b) and added footnote 3.2-9 Italicized last paragraph of section 3.2.5.3 and added footnote DCD only 3.2-17 Changed items 8,9,10 to "Not Used" DCD only 3.2 19 Changed items 8, and 9 to "Not Used" DCD only 3.2-20 Changed item 19 to "Not Used" DCD only I j 3.2-24 Changed hems 3, and 4 to "Not Used" DCD only l l 4 SSAR-6 i

Alignment of SSAR with DCD DCD Section/Pg Difference Action 3.2-33 Changed items 5, and 6 to "Not Used" DCD only 3.2-36 Changed items 2, 3(k 1) and N 1(1) (2) to "Not Used" DCD only j 3.2-52 Changed item 6 to "Not Used" DCD only 3.2-63 Italicized text six places added footnote DCD only i 3.3-3 Deleted date from ASCE 7 Update SSAR Unitalicized references DCD only 3.4-15 Replaced ABWER with ABWR Update SSAR l 3.4.2 3.4-16 Unitalicized references DCD only 3.5-8 Equation 3.5.3 Removed small dashes over the f Update SSAR .5.5-14 Unitalicized references DCD only 3.6-1 Last paragraph removed "this SS AR" replaced with ' Tier 2" DCD only 3.6-2 Unitalicized title of Criterion 4 DCD only i 3.6.1.1.I i 3.6-12-17 Italicized text added footnote DCD only j 3.6-20 Unitalicized item 2 DCD only i 3.6.2.2.I j 3.6-22-26 Italicized text added footnote DCD only 1 l 3.6-29 Changed "ABWR SSAR" to " Tier 2" in second paragraph DCD only I 3.6-33, 34 Unitalicized references DCD only ~ 3.7-8,9 Italicized text added footnote DCD only 3.7-21 Italicized text 3 places added footnote DCD only i SSAR-7 .----m

f Alignment of SSAR with DCD DCD Section/Pg Difference Action 3.7-22, 23 Italicized text added footnote DCD only l 3.7-24 First paragraph changed "SSAR" to " Tier 2" DCD only 3.73.3.3.14 i 3.7-25 Italicized text added footnote DCD only l 3.7-26 Italicized text added footnote DCD only 3.7-27 Italicized text Added footnote DCD only 3.7-28 Italicized text added footnote DCD only j 3.7-29 Italicized text added footnote DCD only l 3.7-30, 31 Italicized text added footnote DCD only h 3.7-32, 33 Italicized text added footnote ~ DCD only i 3.7-35-41 Italicized text added footnote DCD only i 3.7-39 Changed "lV" to "III" in last sentence Update SSAR 3.7.3.8.1.9 1 3.7-40 Item (3) Changed "of this SSAR" to "of Tier 2" DCD only 4 3.7.3. I 2 3 3.7-40, 41 Italicized text two places, added footnote on page 3.7-41 DCD only 3.7.3.13 i 3.7-46 Item (b) changed "the SSAR" to " Tier 2" DCD only l-3.7-47 Unitalicized references Changed " Deleted" to "Not Used" DCD only

i 3.7-73 Changed " Deleted" to "Not Used" DCD only 3.8-2 Added italicized paragraph and footnote DCD only 3.8-3 Added italicized paragraph and footnote DCD only 3.8-20 Italicized text added footnote DCD only 3.8.2.2.3 SSAR-8

Alignment of SSAR with DCD DCD Section/Pg Difference Action 3.8-22 Italicized text added footnote DCD only 3.8.2.4.1.4 3.8-27 Added italicized paragraph and footnote DCD only 3.8-28 Added italicized paragraph and footnote DCD only 3.8-30 Italicized text added footnote DCD only 3.8-32 Unitalicized NCIG titles, put in quotes DCD only 3.8.3.8 3.8-35 Italicized Item (1) added footnote DCD only 3.8-36 Italicized item (2) added footnote DCD only Changed " Table 3.8-10" to " Table 3.8-9" in Reference (2) Update SSAR Unitalicized the rest of the items DCD only 3.8-37 Removed "88" from ANSI /ASC17 Update SSAR 3.8-37 Unitalicized Items DCD only 3.8-38 Unitalicized first line DCD only Italicized text in two places DCD only Unitalicized last items DCD only 3.8-42 Changed "1.96 kPa" to "19.61kPa" Update SSAR 3.8.4.3.2 3.8-44 Italicized first paragraph DCD only 3.8.4.4.I 3.8-44 Replaced "AISC" with " ANSI /AISC 690" in Section 3.8.4.4.1 Update SSAR 3.8-46 Added italicized sentence,3 places, added footnote DCD only 3.8-46 Changed title from " Materials Criteria" to "Stmetural and Materials Update SSAR and omit 3.8.4.5.1.2 Criteria" and added italicized sentence pertaining to acceptance criteria italicization SSAR-9

Alignment of SSAR with DCD 1 DCD Section/Pg Difference Action 3.8-47 halicized text footnote DCD only 3.8.5.2 1 3.8-54 Italicized items 13,14,15 - Changed designation of item 15 DCD only j Changed " Deleted" to "Not Used" 3.8-54 Changed " Table 3.9-10" to " Table 3.9-9" in Reference 15. Update SSAR 3.8-55 Changed Orientation of table; Removed Note i Update SSAR i 3.8-60 Italicized (1) thru (6), footnote DCD only 3.8-60 Item 7(c) added the word "with" Update SSAR l 3.8-61, 62 Italicized text footnote DCD only 3.8-72 Changed " Deleted" to "Not Used" DCD only 3.8-74 Chang,eu " Deleted" to "Not Used" DCD only 4 3.8-77 Changed " Deleted" to "Not Used" DCD only 3.9-1 Italicized text added footnote DCD only 3.9-7 Added Subsection and footnote DCD only 3.9-14 Italicized text three places, added footnote DCD only j 3.9-23 Unitalicized item (1) DCD only 3 3.9-24 Unitalicized hems (2) and (3) DCD only ) 3.9-28 Italicized text, added footnote DCD only i From third paragraph removed "Either a schedule 40 pipe wall Update SSAR thickness, or" and added "but no less than that of a schedule 40 pipe" j following term " Reactor coolant system pressure". j 3.9-29 Added italicized paragraph summarizing Supplement 3 to Bulletin Update SSAR without Italics 88-08 and how ABWR addresses l j ltalicized text, added footnote DCD only 4 1 1 SSAR-10 2 i

Alignment of SSAR with DCD I DCD Section/Pg Difference Action 3.9-30 In seventh line of paragraph beginning "The safety relief..", changed Update SSAR capital " Safe Shutdown" to lowercase 3.9-32 Italicized text, added footnote DCD only 3.9-36 Added last two lines on page 3.9-36 pertaining to seismic anchor Update SSAR without italics j motions and italicized 3.9-36 Italicized text, added footnote DCD only 3.9-37 Italicized text, added footnote DCD only I 3.9-41 Italicized text, added footnote DCD only 3.9-42 Italicized text, added footnote DCD only 3.9-45 Italicized sentences, added footnote DCD only 3.9-50 Italicized text, added footnote DCD only 3.9-51 Italicized text, added footnote DCD only 4 l 3.9-52 Italicized text, added footnote DCD only 3.9-53 Italicized text, added footnote DCD only l 3.9-54 Italicized text, added footnote DCD only 3.9-55 Italicized sentence, added footnote DCD only 3.9-56 Moved sentence pertaining to RG 1.84 from Item (6)(b) to (6) (a) Update SSAR j Italicized text, added footnote DCD only 1 3.9-62 Added " coolant water, and literally locate and support the fuel Update SSAR 3.9.5.1.1 assemblies. Figures 3.9-2 and 3.9-3 show the reactor vessel internal flow paths." following the last line of the paragraph. 3.9-67 Second paragraph, removed duplicate sentence Update SSAR 3.9-77 Added first paragraph DCD only i ' SSAR-li s 4 ___.._..___._____.__________._.___.____4-____._.___.-.__.________._______m_.._.__-._--..____._________._.___..___________....._-____..-.__.__._____-___..___________._m_-_______.________________,.*=rmw ew --u

i .t f _ Alignment of SSAR with DCD DCD Section/Pg Difference Action ] 3.9-77, 78 Italicized text, added footnote DCD only 3.9-84 Removed items 3.9.7.5 thru 3.9.7.10 Update SSAR Italicized references 3.9-6,7,9,10,11 DCD only l Unitalicized the rest of references l Added date to Reference 3.9-11 Update SSAR 3.9-86 Italicized Event 12 and Note 6, added footnote DCD only 3.9-87 Removed commas from lleading 2 DCD only l Italicized Event 3, Added footnote DCD only j 3.9-87 Event 4 change " Deleted" to "Not Used" DCD only 3.9-88 Italicized Notes 7 and 9 and 12, added footnote DCD only 3.9-99 Changed "SSAR" to " Tier 2" in table heading DCD only 3.9-139 Deleted "SS AR" under notes (a) and (d) DCD only 4 3.10-1 Added italicized paragraph and footnote DCD only i 3.10-2 Italicized text, added footnote DCD only 3.10-3 Italicized text, added footnote DCD only i 3.11-5 Italicized reference 2, added footnote DCD only 3.13-11 Changed "SSAR" to " Tier 2" DCD only i j 3.13-14 Replaced " are less that 1% of" with "is a very small percentage of" in DCD only the last paragraph 3.13-14 Changed "Section 15.5.6" to "Section 15.6.6" at end of line Update SSAR - 3A-3 Equation 3A-1, added "218.8", added "kPa" to Gmax Update SSAR 3A-85 Provided correct figure for El-10.95 Update SSAR i. SSAR-12 m .m ..wr.+..s w ,-e-_,____

t Alignment of SSAR with DCD DCD Section/Pg Difference Action j 3A-295,296 Reversed these figures Update SSAR Att 3AA Removed Att 3AA DCD only 3B-27 Replaced "SSAR" with " Tier 2" in first paragraph DCD only 3 B.4.4.1 3B-31, 32 Unitalicized references DCD only 3B-34, 78 Replaced "provided under separate cover" with "not part of DCD DCD only j (Refer to SSAR)" in appropriate places j 3D-4 Changed " Deleted" to "Not Used",2 places DCD only 3D-5 Changed " Deleted" to "Not Used" DCD only l 3E-24 Unitalicized paragraph headings DCD only j 3 E.6.1.2 3E-25 Unitalicized references DCD only Changed reference 10 to "Not Used" { 3E-43 Removed duplicate titic from Ogure Update SSAR 3F-1 Changed title to "Not Used" DCD only l 3G-14 Replaced figure 3G-1 from "81 IlORIZONTAL" to "33 Update SSAR HORIZONTAL" 311.0-ii Added listing for Subsection 311.5 Update SSAR 311.0-vii Changed " Deleted" to "Not Used" all places DCD only 3H.0-viii Changed " Deleted" to "Not Used" all places DCD only i 311.1-3 Italicized text, Added footnote DCD only I Update (1) to retlect updated Table 2.0-1 Update SSAR 3 11.1-4 Revised (4) and (7) to reflect updated Table 2.0-1 Update SSAR 3 H.1-4, 5 Revised (8) to reflect updated Tab!e 2.0-1 Update SSAR 1 { SSAR-13

1 Alignment of SSAR with DCD DCD Section/Pg Difference Action Removed Minimum Translational Speed from (8) Update SSAR 3 H.1 -5 Removed "-88" from (9) Update SSAR I 3H.1-7 Revised Snow Load and Wind Load parameter to reflect Table 2.0-1 Update SSAR 3H.1-13 Updated Shearwave to reflect Table 2.0-1 Update SSAR 311.1-57/58 Removed blank pages DCD only 3H.1-62/63 Removed blank pages DCD only 3H.1-65 Removed blank pages DCD only 3H.1-68 Removed blank pages DCD only 2 3 H.1-70 Removed blank pages DCD only 3H.1-73 Removed blank pages DCD only 3H.1-75 Removed blank pages DCD only 3H.1-77 Removed blank pages DCD only 3H.1-88 Changed " Deleted" to "Not Used" DCD only 3 H.1-104 Changed " Deleted" to "Not Used" DCD only 1 ] 3 H.2-2 Italicized text, added footnote DCD only i 3 H.2-2 Revised Parameters to reflect Table 2.0-1 Update SSAR Deleted date from ASCE-7 Update SSAR i 3 H.2-5 Revised Tornado Parameters to reflect Table 2.0-1 Update SSAR 4 Removed date from ASCE-7 Update SSAR 3H.2-6 Revised Parameters to reflect Table 2.0-1 Update SSAR i 1 l 3 SSAR-14

t Alignment of SSAR with DCD t j ] DCD Section/Pg Difference Action Removed Minimum Translational Speed Update SSAR Removed date from ASCE -7 Update SSAR 3H.2-12 Removed date from ASCE-7 Update SSAR l 3H.2-2 i Changed " Deleted" to "Not Used" DCD only 3H.2-30 Replaced " psi" with " psf" Update SSAR .i 3 H.3-2 Italicized text, added footnote DCD only j Revised parameters to reflect Table 2.0-1 Update SSAR Removed date from ASCE-7 Update SSAR f 311.3-4 Revised parameters to reflect Table 2.0-1 Update SSAR Removed date from ASCE-7 3H.3-5 Revised parameters to reflect Table 2.0-1 Update SSAR Removed date from ASCE-7 3H.3-29 Changed "0.15ksi" to "7.18 kPa" and " 4.48 ksf" to " 215kPa" Update SSAR 3H.4-6-13 Figures have been recreated DCD only 31-6 Removed deleted footnote 1, renumbered footnotes Update SSAR 31-7 Deleted footnotes i and 3, changed "40" to "50" for diesel generation Update SSAR Table 31-4 room, renumbered footnotes Table 3I-5 Removed Deleted footnote 1, renumbered footnotes Update SSAR 3K Added entire appendix DCD only 3L-1 First paragraph replaced "SSAR" with " Tier 2" DCD only 3L-10 Removed Figure 3L-3 DCD only 3M-3 Unitalicized "3 meter board" DCD only SSAR-15

i Alignment of SSAR with DCD DCD Section/Pg Difference Action 3M-5 Changed "SSAR Figure No." to " Tier 2 Figure No." DCD only 3M-6 Changed "in the SSAR" to "in Tier 2" DCD only 3M.7(1) 3M-7 Replaced "SSAR" with " Tier 2",2 places DCD only 3M.8 3M-8 Added space between "approximately" and "0.93" last line DCD only 3M.10 3M-9 Unitalicized references DCD only 3MA-3 Replaced "SSAR" with " Tier 2" first line DCD only 4 3MA-10 Replaced "SSAR" with " Tier 2" first line DCD only I 3MA-13 to end Changed "SSAR Figure" to " Tier 2 Figure" DCD only 3MA-32 Removed white space at top of page DCD only 4 3MA-34 Removed white space at top of page DCD only Chapter 4 4.0-v Removed Figure 4.2-3 entry DCD only i 4.1-2 Removed period from title DCD only 4.1.2.1.1 4.1-8 Unitalicized references DCD only 4.2-1 Added italicized paragraph with footnote DCD only Italicized sentences added footnote 4.2-3-5 Italicized text, added footnote DCD only 4.2-5,6 Italicized text, added footnote DCD only 4.2-6 Italicized text added footnote DCD only 4.2-7 Added date and " proprietary" for NEDE 3112P Update SSAR SSAR-16

Alignment of SSAR with DCD DCD Section/Pg Difference Action 4.2-7 Changed " Subsection 4.2.4" to " Reference 4.2-3" and italicized Update SSAR without italics 4.2.3.1.2, 4.2.4 second sentence of Section 4.2.4 4.2-8, 9/10 Italicized figure titles, added footnote DCD only 4.3-2 Italicized sentence of first paragraph added footnote DCD only ) i 4.3-7 Unitalicized references DCD only 4.3-9 Italicized figure title, added footnote DCD only 4.3-10 Replaced "provided under separate cover" with "not past of DCD DCD only { (Refer to SSAR section 4.3)" 4.4-5 Removed duplicate AL line from page Update SSAR i 4.4-10 Changed " Deleted" to "Not Used" DCD only j 4.4.3.5 4.4-17, 18 Unitalicized references DCD only f l 4.5-5 Unitalicized headings DCD only j 4.5.2.1 4.6-18 Changed "sec" to "s" Update SSAR 4.6-21 Removed "the" from the first line Update SSAR 4.6-23 Modified grammar and spelling in sixth paragraph. Replaced period Update SSAR with comma in first paragraph 4.6-25 Changed "are" to "is"in item (e) Update SSAR 4.6.3.2(c) 4A-1 Italicized text, added footnote DCD only Unitalicized references 4A-2 Changed "GWd/MT" to "GWd/t" Update SSAR Table 4A-2 4 4A-3-42 Proprietary title was changed DCD only 4B-1/2 Added paragraph, italicized sentences, added footnote DCD only I 4C-1, 2 Italicized text, added footnote DCD only i SSAR-17

i Alignment of SSAR with DCD 4 DCD Section/Pg Difference Action 4D-1 Removed Proprietary information, referenced SSAR DCD only Chapter 5 5.0-TOC Added listing for appendix subsections SA and 5B Update SSAR 5.0-v Changed " Deleted" to "Not Used" DCD only 5.1-1-3 Unitalicized heading DCD only 5.1-5 Updated figure Update SSAR 5.2-14 Item (1) changed "corrision" to " corrosion" Update SSAR 5.2.3.2.2.3 5.2-17 (15)(c), corrected misspelled " success" Update SSAR 5.2-18 Changed "corrision" to " corrosion" in first line Update SSAR 5.2.3.2.2.4 5.2-30 Added " Appendix 5A demonstrates compliance with Regulatory Update SSAR 5.2.4.3.2.1 Guide 1.150" at end of section 5.2-41 Removed last paragraph Update SSAR 5.2.5.2.1 5.2-41 Added "RilR" in front of" Shutdown Cooling System" in third line of Update SSAR 5.2.5.2.2 item (2) 5.2-44 Replaced "RCU" with "RCW" Update SSAR 5.2.5.2.2(l 1) added period after variable 5.2-45 Changed " pickings" to " packings" Update SSAR 5.2.5.4.2 5.2-49, 50 Unitalicized references DCD only 5.2-50 Corrected spelling of" Degradation" in two places Update SSAR 5.2-51-53 Italicized selected code cases DCD only Added case N-476 Update SSAR 5.2-53 Added listing (26a) Update SSAR SSAR-18

Alignment of SSAR with DCD DCD Section/Pg Difference Action 5.3-14 Added " located between the two seal rings. A monitor line is attached Update SSAR to the top to provide an indication of leakage from the inner seal-ring seal" to top of page 5.3-20 Unitalicized references DCD only 5.4-2 Added "and" in front of (2) in last paragraph Update SSAR 5.4-1 I Changed "300m/sec" to "300m/s" Update SSAR 5.4.4.5 5.4-15 Replaced "sec" with "s" two places in item (1) dpdate SSAR 5.4.5.3 5.4-16 Replaced " sections" with "s" Update SSAR 5.4.5.4 5.4-19 Removed white space DCD only 5.4-23 Changed "so" to "for" Update SSAR 5.4.6.2.1.3(3) 5.4-28 Changed " reset" to " resets" in next to last sentence Update SSAR 5.4.6.2.5.2 5.4-28 Changed colon after 5.4.6.2.5.2 to a period. Update SSAR 5.4.6.2.5.4 5.4-28 Changed "electricaally" to " electrical" in first line Update SSAR 5.4.7.I 5.4-29 Added " pressure" in front of " design" in fourth to last line of subsection Update SSAR 5.4.7.1 5.4-34 Changed "but" to "by" in first sentence of second paragraph of Update SSAR Section 5.4.7.1.1.10.1 5.4-36 First paragraph - Changed "sec" to "s" two places Update SSAR 5.~.1.1.10.3 5.4-58 Unita;icized references DCD only 5.4-66 Changed "32.6 C" to "37.8 C" Update SSAR 5A-1 Removed white space DCD only 5A.2 SS AR.

Alignment of SSAR with DCD 4 DCD Section/Pg Difference Action 5A-2 Changed " examination" to " examination" Update SSAR 5A.3(2) 5A-4 Changed "amy" to "may" Update SSAR 5A.4.3 4 i 5A-5 Changed " ben" to "been" Update SSAR l 5A.8 5A-5 Added "is" after " data"in first line DCD only 5A 8.2(2) 5A-6 Replaced "ha" with "hr," in third paragraph of subsection Update SSAR 5A.10 Att 5AA,5AB Removed Attachments from document DCD only Chapter 6 6.0-ii Added subsection listings for Appendices 6C,6D and 6E Update SSAR 6.0-iv Added listing for 6C tables Update SSAR I 6.0-LOF Changed " Deleted" to "Not Used" DCD only 6.1-2 Changed " Deleted" to "Not Used" DCD only 6.1.1.1.3.6 6.2-6 Removed white space DCD only 6.2-14 Removed Subsections 6.2.1.1.3.5, 6.2.1.3.5.1 and 6.2.1.3.5.2 Update SSAR 6.2-19 Unitalicized headings DCD only 6.2-10 Unitalicized headings DCD only 6.2-26 Added " sense a gap between the disk and the seating surface. If the Update SSAR 6.2.1.1.5.5 gap is less than 9mm" third.line of paragraph 6.2-27 Added "to be" in front of"no" third line of second paragraph Update SSAR 6.2.1.1.5.6.1 l Changed " Deleted" to "Not Used" DCD only 6.2-33 Item 5 second paragraph, fixed typo in coolability Update SSAR SSAR-20

l Aligmnent of SSAR with DCD. i DCD Section/Pg Difference Action 4 6.2-36 Added period after 0.4m Update SSAR 6.2.1.1.10.4.2 6.2-61 Deleted "various", added " containment isolation" before " signals in Update SSAR the seventh paragraph j 6.2-62 Added "of GDC 54" in front of"that no active failure..." in first Update SSAR l l paragraph j 6.2-63 Replaced "non-powered" with " manual" in front of " isolation" in last Update SSAR paragraph ] 6.2-63 Added " power operated" in front of " isolation valve arrangements..." Update SSAR 6.2.4.2.6 in fifth paragraph of section. l 6.2-66 Added "the" before "other" last line of paragraph Update SSAR 6.2-71 Removed period after title DCD only l 6.2-81-87 Replaced numerical values with word values for consistency with DCD only i { appendix 19E r 6.2-84 Changed "15%" to "37%" in first paragraph Update SSAR a 6.2-102 Unitalicized references DCD only i 6.2-125-167 Changed "SSAR" to " Tier 2" DCD only 6.2-211-212 Changed " Deleted" to "Not Used" DCD only 6.2-237 Changed "IlYDRYGEN" to " HYDROGEN" Update SSAR Figure 6.2-41 6.3-14/15 Unitalicized headings DCD only l 6.3-25 Unitalicized references DCD only 1 i 6.3-30 Corrected spelling of " design" and " involve" in the first line of the Update SSAR i footnote 5.3-32 Changed proprietary statement to refer to SSAR DCD only 1 j 6.3-41-44 Changed "a least" to "at least" in the first footnote Update SSAR i 6.3-44 In third line of second column changed "PFL" to "LPFL" Update SSAR I SSAR-21 1

4 Alignment of SSAR with DCD DCD Section/Pg Difference Action 6.3-45 Changed " Deleted" to "not Used" DCD only 1 6.3-49 Changed " Deleted" to "Not Used" DCD only l 6.3-50-8'7 Changed proprietary statement so that it refers to the SSAR DCD only 6.4-2 Changed "emergengy" to " emergency" under item (4) Update SSAR 6.4-7 Changed "2.7%" to 25%" in the third column of the table under Update SSAR halogens 6.4-8 Added "is" before "normally" in first line of second paragraph Update SSAR 6.4.4.2 6.4-8 Removed duplicate "...with portable air analyzers indicate the need to Update SSAR do so. Ilowever, the operator is allowed..." from bottom of page 6.5-6 In item (2) corrected the spelling of" occurred". Update SSAR 6.5-10 Corrected spelling of "cannot" in first sentence of first paragraph Update SSAR 6.5.1.7 6.5-11 First line, last paragraph on page changed " preform" to " perform" Update SSAR 6.5-13 Changed " Deleted" to "Not Used" DCD only 6.5-13 Unitalicized references DCD only 6.6-2 Changed " Deleted" to "Not Used" DCD only 6.7-1 Added "providing nitrogen for" at end of first sentence of second Update SSAR paragraph 6.7-2 Changed " safety portion" to " safety-related portion" in first line of Update SSAR paragraph 6A-1 Unitalicized heading DCD only 6A-12 Added " activated carbon is greater than two inches deep, each Update SSAR representative" to top of page 6B-2-9/10 Unitalicized table headings DCD only 6C-1-5 Removed white space DCD only j i SSAR-22

Alignment of SSAR with DCD DCD Section/Pg Difference Action 6C-5 Changed "130m%" to "1130m'/h" in next to last line Update SSAR l 6E-1 Removed white space DCD only Chapter 7 7.1-2 Added italicized paragraph and footnote DCD only 7.1-5 Removed Duplicate "it" in the third line Update SSAR 7.1.1.6.6 7.1-7-11 Italicized text added footnote DCD only 7.1-12 Changed item (k) from " Deleted" to "Not Used" DCD only 7.1-27 Changed " Deleted" to "Not Used" DCD only 7.1-31 Added italicized paragraph and footnote DCD only 7.2-5 Changed item (8) to "Not Used" DCD only 7.2-11 Changed item (5) to "Not Used" DCD only 7.2-11 Changed "sec" to "s" in eighth line of item (5) Update SSAR 7.2.1.1.4.3 7.2-32 Italicized Reg. Guide 1.105 added footnote DCD only 7.2-40 Changed item (12)(d) to "Not Used" DCD only 7.2-56 Changed " Deleted" to "Not Used" DCD only 7.3-19 Changed RCIC minimum flow from "5s" to "15s" Update SSAR 7.3-56 Removed blank line from top of page DCD only 7.3-70 Unitalicized 3(a) DCD only 7.3-71 Unitalicized items (b', (c),(d) DCD only SSAR-23

Aligmnent of SSAR with DCD DCD Section/Pg Difference Action 7.3-72 Unitalicized (e) DCD only Italicized (f) added footnote 7.3-73-end Unitalicized all list items DCD only i 7.3-96 Italicized reference 7.3-2 DCD only { Changed " November" to " October" Update SSAR i 7.4 Unitalicized list items DCD only i 7.4-24 Italicized Reg Guide 1.05 added footnote DCD only 7.5-6 Added end quote to last line of second paragraph Update SSAR 7.5-11 Removed comma after "drywell" in first line of itemj paragraph DCD only I 7.5-14 Unitalicized titles in first paragraph in table DCD only i l 7.5-15 Moved period to end oflast line Update SSAR 7.5-24-27 Changed " Safety Analysis" to " Tier 2" in third column DCD only 7.5-28 Replaced "S" with "T" in the right hand column and "S=SSAR" with DCD only "T= Tier 2" in footnote 1 7.6-3 Changed "nv" to " neutron /cm'" four places Update SSAR 1 7.6-7 Changed "84.37 kg/cm'g" to "8.27 MPaG" Update SSAR 7.6-15 Changed " Deleted" to "not Used" DCD only 7.6-19 Changed "by" to "be" in Section 7.6.1.7.6 Updata SSAR 7.6-23-end Unitalicized list items DCr;only 7.6-23 Italicized item 3f added footnote DCD only 7.6-27 Repied "SSAR" with " Tier 2" DCD only 7.6-29 Changed "Deletea" te "Not Used" DCD only t 4 SSAR-24

Alignment of SSAR with DCD DCD Section/Pg Difference Action 7.6-30 Italicized item (f) added footnote DCD only 7.6-46 Changed " Deleted" to "Not used" DCD only 7.6-47 Removed duplicate title in body of figure Update SSAR - i i 7.7-26-end Unitalicized list items DCD only 7.7-28 Changed " Fall-In" to " Full-In" under item ( t) (c) of Section 7.2.1.2.2 Update SSAR 7.7-42 Changed "sec" to "s" in last paragraph Update SSAR 7.7-54 Removed white space DCD only 7.7-67 Removed white space DCD only 7.7-77 Replaced "of the SSAR" with "of Tier 2" in first line DCD only i 7.7-87 Moved this section from page 7.7-88 DCD only 7.7.2. I I i 7.7-90 Changed " Deleted" to "Not Used" DCD only 7A-1 Added two italicized paragraphs with footnotes DCD only 7A-2-12 Italicized all of section 7A.2. Added reference to IEEE 518 and 1050 Update SSAR except for under item (4) on page 7A-4 with footnote and modified reference to italics and footnotes i ANSI FDDI under item (10) on page 7A-7 7A-8 Changed "the SS AR" to " Tier 2" in response (11) DCD only 7A-9 Replaced "lEEE 1033" with "IEEE 1042" Update SSAR j 7A-11 Changed "(5)" !a "(6)" and "(6)" to "(7)" in response (14) Update SSAR l 7A-12-15 Italicized all of Section 7A.3 and added footnote DCD only 7A-16-20 Italicized Sections 7A.5 thm &a.7 and added footnote DCD only 78-1 Changed "lEEE (draft h)

  • to "lEEE 1228 (draft)" under item Update SSAR 78.l(a)(iv) i

} SSAR-25

Alignment of SSAR with DCD DCD Section/Pg Difference Action 7B-1, 4, 5 Added subsection designations 78.1,7B.2, and 78.3 and removed (1) Update SSAR 78-1-7/8 Italicized Sections 7B.1 thru 78.3 added footnote DCD only 7C-2-5 Italicized Section 7C.2 and 7C.3 added footnote DCD only 7C-5 in first paragraph changed "less than 10E-6" to " extremely low" DCD only 7C-8 Replaced "2200 F' with "1204 C" under JUNE 1992 Update SSAR 7C-11-13 Italicized Section 7C.5 added footnote DCD only 7C-14 Unitalicized references DCD only Chapter 8 8.1-4 Changed item 3(d) to "Nc' Used" DCD only ~ 8.2-6 Removed white space DCD only 8.2-9 Changed "the SSAR" to " Tier 2" in first paragraph DCD only 8.2-15 Changed "SS AR" to " Tier 2" on first line DCD only 8.3-2 Removed white space DCD only 8.3-23 Removed extra comma after outputs in fourth line of paragraph DCD only 8.3-43 Changed "is" to "are" in first paragraph Update SSAR 8.3.3.6.I 8.3-55 Changed " Deleted" to "Not Used" DCD only 8.3-56 Changed " Deleted" to "Not Used" 8 places DCD only 8.3-56 Removed white spaces DCD only 8.3-57 Changed " Deleted" to "Not Used" DCD only 8.3-59 Changed " Deleted" to "Not Used" DCD only SSAR-26

Alignment of SSAR with DCD DCD Section/Pg Difference Action 8.3-61 SECY-89-013 Changed " State" to " States" Update SSAR 8A-1 In second paragraph, added beginning parenthesis Update SSAR Chapter 9 9.0-kii Changed " Deleted" to "Not Used" DCD only 9.0-vii Changed " Deleted" to "Not Used",2 places DCD only 9.0-viii Changed " Deleted" to "Not Used" 2 places. Changed the title of Update title of figure in SSAR Figure 9.4-4; changed " Essential" to " Safety-Related" 9.1-2 Changed " Deleted" to "Not Used" DCC only 9.1-4 Removed white space DCD only 9.1-6 Changed "1361 kg" to "13.35kN" under Item 6 Update SSAR 9.1-14 Removed white space DCD only 9.1-35 Removed white space DCD only 9.1-42 Removed white space DCD only 9.1-43 Removed white space DCD only 9.1-48 Changed " Deleted" to "Not Used" DCD only 9.1-54 Unitalicized 2 lines DCD only 9.1-55 Unitalicized I line DCD only 9.1-64 Corrected spelling of"Fule to " Fuel" before " Isolation Container" Update SSAR 9.2-6 Changed "37.8 C" to "35 C average" at end of Item (1) Update SSAR 9.2-12 Removed white space DCD only 9.2-12 Deleted second "well" in first line of paragraph Update SSAR 9.2.8.3.1 SSAR-27

Alignment of SSAR with DCD DCD Sectioa/Pg Difference Action 9.2-20 Changed "37.8 C" to "(i.e.,35 C average)"in second line of second Update SSAR paragraph 9.2-21 Inserted second paragraph Update SSAR 9.2.11.1 9.2-22 Removed "due to tube plugging" in paragraph beginning with " The Update SSAR above analysis shows..." 9.2-25 Removed white space DCD only 9.2-25 Removed "the tubing side" from paragraph beginning with " System Update SSAR components" 9.2-27 Replaced " tube plugging" with " leakage" in next to last sentence in Update SSAR first paragraph Replaced "retubing" with " refurbishing" in last word of first Update SSAR paragraph Replaced "a tube leak" with " leakage" in the next to last paragraph Update SSAR 9.2-31 Deleted " centrifugal" in front of compressor in the third sentence of Update SSAR the second paragraph 9.2-34 Changed last sentence of third paragraph to read "two-way valve Update SSAR based on refrigerant compressor discharge pressure" 9.2-43 Removed white space DCD only 9.2-46 Removed white space DCD only 9.2-50 Changed "54.01" to "127.24" in the fourth column of the total load Update SSAR entry 9.2-36 Changed "450m'/r" to "450m'/h" and "420 m'/hr" to 420 m'/h" and Update SSAR " Capacity m'/hr" to "Capucity m /h" 3 9.2-58 Removed " type-centrifugal hermetic" Update SSAR Changed "2.5 i GJ" to "2.51 GJ/h" 9.2-6i Changed " Deleted" to "Not Used" DCD only 9.2-67 Changed " Deleted" to "Not Used" DCD only 9.3-5 Changed " Reactor" to " Turbine" in front of" Building Sample Station" Update SSAR SSAR-28

Alignment of SSAR with DCD DCD Section/Pg Difference Action 9.3-9 Replxed 'This" with "That" in second paragraph Update SSAR 9.3.3.1.3 9.3-9 Replaced "in" with "is" in the third line of paragraph Update SSAR 9.3.3.2 9.3-9 Removed "(Subsection 9.3.2.1)" from the first line of subsection Update SSAR 9.3.3.2 9.3-9 Changed "is" to "are" Update SSAR 9.3.3.2.I 9.3-13 Changed item (a) from "Iligh RPV pressure (7.76 MPaG) and Update SSAR average power range monitor (APRM) not downscale for 3 minutes, or" to "lligh RPV pressure (7.76 MPaG) and startup range neutron monitor (SRNM) not downscale for 3 minutes, or" 9.3-18 Removed "which" following " isolation valves" in fourth paragraph Update SSAR 9.3.6.2 9.3-21 Removed "which" following " isolation valves" in fifth paragraph Update SSAR 9.3.7.2 9.3-22 Added last paragraph "Outside primary containment a manually-Update SSAR operated valve is kept closed and locked during normal plant operation. During refueling, the valve is opened to provide air inside containment." 9.3-24 Removed "and system" in second line of first paragraph Update SSAR 9.3-33 Changed " Deleted" to "Not Used" 3 places DCD only 9.3-34 Changed "85.8" to "8.41" in next to last column under Pump Update SSAR Discharge in Injection Valve Inlet entry 9.4-8 Removed "at El. 7200 in C/B" from end of sentence in (6) Update SSAR 9.4-18 Added " On a smoke alarm in a division of the secondary containment Update SSAR HVAC system the HVAC System shall be put into smoke removal mode. To remove smoke from the secondary" to top of first paragraph 9.4-24 in second paragraph, changed "46 C" to "46.1 C" changed "45 C" to Update SSAR "50 C"in two places 9.4-27 Gmnged "45 C" to 50 C" in top second sentence Update SSAR SSAR-29

l Alignment of SSAR with DCD DCD Section/Pg Difference Action 9.4-40 Changed "sec" to "s" - two places Update SSAR 9.4-46 Changed Deleted to Not Used DCD only I 9.4-55 Changed " Deleted" to "Not Used" 2 places DCD only Unitalicized " Requirement" and " Compliance" throughout section DCD only 9.5-9 Changed item (5) to "Not Used" DCD only 9.5-10 Changed " Deleted" to "Not Used" DCD only 9.5-13 Changed " Deleted" to "Not Used" DCD only 9.5 22 Removed white space DCD only j 9.5-24 Replaced last sentence with " Fire detection and alarm systems are Update SSAR supplied with power from a Non-ClasslE uninterruptible power supply" in first paragraph of subsection 9.5.1.3.9. i 9.5-66 Changed "sec" to "s" in third and fourth paragraphs, three places total Update SSAR l 9.5.I2.2 9.5-69 Removed probabilities at end of first paragraph DCD only } 9.5. I 2.3.3 j 9.5-68 Changed "sec" to "s" in second to last paragraph Update SSAR 9.5. I 2.3. I 9.5-7 i Changed " Deleted" to "Not Used" in item (1) DCD only 9.5-74 Changed " Deleted" to "Not Used" DCD only 9.5.I3.12 l 9.5-76 Unitalicized references DCD only 9A-TOC Changed " Deleted" to "Not Used" 48 places DCD only 9A.2-4 Removed white space DCD only 9A.2-5 Item (10) Changed " Deleted" to "Not Used" DCD only 9A.2-7 Changed "SSAR" to ' Tier 2"last line DCD only l SSAR-30 i t

i Alignment of SSAR with DCD DCD Section/Pg Difference Action 9A.2-8, 9 Changed "SSAR" to " Tier 2" at top of fifth column and footnote DCD only 9A.3-2 Changed " Deleted" to "Not Used" DCD only 9A.4 Changed " Deleted" to "Not Used" throughout DCD only Unitalicized " Water level (Flood) Design throughout 9A.4-53 Changed "RCWU" to "CUW" Update SSAR 9A.4-239 Removed white space DCD only i 9A.4-480 Changed "with No.2 fuel oil with min. flash point of 377 C" to "with Update SSAR j minimum flash of 37.8 C" ) 9A.4-501 Removed "(C-size,17" x 22")" from the end of first sentence Update SSAR j 9A.5-13 Changed " Deleted" to "Not Used" DCD only l 9A.5-16,17 Changed " Deleted" to "Not Used DCD only Unitalicized paragraph headings { 9A.5-16 Removed "of the SSAR" in two places DCD only 9A.5-17 Removed Section 9A.5.8 DCD only 9B Unitalicized paragraph titles DCD only ] 9B-10 Unitalicized references DCD only 9C-9 Removed white space DCD only Chapter 10 10.1-6 Corrected spelling of" considerations"in footnote Update SSAR 10.2-7 Removed Table 10.2-1 DCD only j 10.2-1I Replaced "ASTMA-170" with " ASTM A-370" Update SSAR - J ^ 10.2-16 Unitalicized references DCD only 4 i SSAR-31 l i r y .,-,,,,-,g .-3., ,.m,. ,.m._. m ..c.-.. s.-.. -m

1 Alignment of SSAR with DCD DCD Section/Pg Difference Action 10.3-4 Unitalicized 5 titles DCD only i 10.4-19 Removed section numbers 10.4.5.9, 10.4.5.9.1, 10.4.5.9.2, DCD only 10.4.5.10, 10.4.5.10.1, 10.4.5.10.2 10.4-34 Changed orientation ofTable DCD only l Chapter 11 11.0-iii Changed "hr" to "h" in title of Table 11.3-1 Update SSAR 11.0-iv Removed i1 A table listings DCD only ] 11.0-v/vi Removed iI A figure listings DCD only i i1.1-7 Unitalicized references DCD only 11.1-7 Removed reference i1.1-5 DCD only 11.2-1 At end of second sentence from bottom " receiver tank" changed to " Update SSAR 11.2.1.2 sample tank" and " LCW" insened in front of " sample tanks" j 11.2-5 Changed second line to read "... effluent from the LCW sample tank or Update SSAR d 11.2.3.1 the hot shower drain sample tanks as indicated..." 11.3-25, 26 Unitalicized references DCD only ) 11.5-3 The middle paragraph changed "10CFR20.6" to "10CFR20.1302" Update SSAR I1.5.1.2 and " Amendments I and 2" to " Attachments I and 2" i 11.5-18 Added space between "in" and "the" and "to" and " assure" in last Update SSAR paragraph j 11.5-20 in fifth column, for main steamline tunnel area deleted,"10* to 10~* Update SSAR Amps" and parentheses associated with "10 2 to 10' mGy/h" 11.5-20 la fifth column, for Reactor building vent exhaust, changed Update SSAR ] "102 to 10' mR/h" to "10" to I mGy/h" 11.5-20 In fifth column, for Drywell sump discharge, Update SSAR deleted "10 to 10 Amps" and parentheses associated with 4 r j "10-2 to 10 mGy/h" 4 ) 11.5-20 In fifth column, for Offgas pretreatment changed "MGy/h" to Update SSAR "mGy/h" SSAR-32

Alignment of SSAR with DCD DCD Section/Pg Difference-Action i1.5-22 In fourth column, for Plant stack discharge, changed to "3.51x 10" to Update SSAR 8 "3.51x 10 " 11.5-22 In fifth column, last entry: Chang *d "3.7x10" to 3.7x 10' MBq/cm'" Update SSAR 1 to '3.7x 10-' to 3.7x 10-3 MBq/cm 11.5-23 In fifth column, for RW Building Ventilation Exhaust, changed Update SSAR l "3.7x10 to 3.7x10-2 MBq/cm " to "3.7x 10-' to 3.7x 10-2 MBq/cm'" 4 3 i1.5-23 Designated footnote in fifth column for entries of Plant Stack and Update SSAR l SGTS Exhaust, Inline Config. (with added footnote to pg 11.5-24). i i1.5-23 In fifth column, third and fifth entries changed "3.6x10*" to Update SSAR "1.33x10*' and in fifth column third entry, changed "3.7x10 to 4 4 3.7x10 " to "3.7x10-' to 3.7x10-3" 11.5-23 First Line, first column, Changed " main" to " Plant" 11.5-24 Added footnote "This dynamic range reflects post accidents Update SSAR conditions; the entry expected activity in this row is for the expected normal activity, i.e., non-accident" i1.5-25 In fourth column changed "3.7x 10~' to 3.7x 10" MBq/cm'" to Update SSAR 4 4 "3.7x10 to 3.7x10 MBq/cm'" 1IA Removed i 1 A List of Tables and List of Figures DCD only Chapter 12 } 12.0-x Added "Gy/h" to end of title for figure 12.3-74 Update SSAR 12.2-12 Unitalicized references DCD only 12.2-32, 33 Added "*" to 8.9E-1 figure and added footnote " Multiply by 6 if Update SSAR Hydrogen Water Chemistry is in Use" 12.2-66 "Nanotesla" changed to " Gamma" under Part A Update SSAR 12.3-20 Changed "1000uGy" to "1000 Gy" under item (3) Update SSAR I 12.3-23 In first paragraph replaced " Certified Design Material (GE Document DCD only 25A5447)" with " Tier 1" l 12.3-26 Replaced "DAC 3.7b" with " Table 3.2b of Tier 1" for DCD and Update SSAR "DAC3.7b" with " Table 3.2b of the CDM" for the SSAR } l i l SSAR-33 i i

Alignment of SSAR with DCD DCD Section/Pg Difference Action 12.3-30 Unitalicized references DCD only 12.3-35 Changed " Deleted" to "Not Used" DCD only 12,3-36 Changed " Deleted" to "Not Used" DCD only l 12.3-37 Changed " Deleted" to "Not Used" DCD only 12.4-8 Unitalicized references DCD only 4 12.4-9/10 Replaced "SSAR" with " Tier 2" DCD only 12A-3 Unitalicized paragraph heading DCD only 12A-4 Unitalicized references DCD only Chapter 13 13.0-iii/iv Removed Table 13.6-1 and 13.6-2 listings DCD only Removed List of Figures DCD only 13.5-4-7 Unitalicized paragraph titles DCD only 1 Chapter 14 14.0-ii Changed " Deleted" to "Not Used" DCD only 14.0-iv Changed CDM to Tier 1,5 places. Revised title of Section 14.3 DCD only 14.2-7 - Unitalicized Reg. Guides DCD only 14.2-60 Removed deleted paragraph section 14.2.12,1.30 DCD only 14.2-140 Changed "62.2 C" to "80 C" Update SSAR 14.2-159 Changed "SSAR" to ' Tier 2" 2 places DCD only 14.2-171 First line removed repeated "steamflow" Update SSAR SSAR-34 l

Alignment of SSAR with DCD DCD Section/Pg Difference Action 14.2-190 Removed deleted paragraph section 14.2.12.2.41 DCD only 14.2-191 Removed deleted paragraph section 14.2.13.3 DCD only 14.3 Relabeling consistent with change from CDM/SSAR to Tier 1/ Tier 2 DCD only 14.3-1 Changed last sentence to " basis for the NRC finding under CFR Part DCD only 52.103(g) 14.3-1 Changed Section Title DCD only 14.3-1 Modified first paragraph to better reflect the Tier 1 information DCD only 14.3-12 Changed "on" to "an" in selection methodolgy last sentence Update SSAR 14.3-12 Changed first sentence of item (3) to "The inspections, tests and Update SSAR analyses are to be completed." by deleteing extra words at the beginning of sentence. 14.3-24, 25, 27, 29, Incorporated editorial corrections, such as including missing left or Update SSAR 30,31,51,59 right parenthesis, both brackets, text alignment, and spelling corrections. 14.3-59/60 Changed " safety" to " safe" and "RSS design basis" to "as seismic" Update SSAR 14.3-24-58 Changed "SSAR entry" to " Tier 2 entry" and "SSAR value" to " Tier 2 DCD only i value" Chapter 15 15.0-ii Changed " Deleted" to "Not Used" DCD only 15.0-vii Changed " Deleted" to "Not Used" DCD only 15.0-ix/x Removed 15C table listings DCD only 15.0-xiv Changed " Deleted" to "Not Used" DCD only 15.0-xv Removed Figure 15B-8 for DCD and replaced Figure 15B-8 title with Update SSAR " Deleted" for SSAR 15.0-xvi Removed 15C figure listings DCD only SSAR-35

Aligmnent of SSAK with DCD DCD Section/Pg Difference Action 15.0-10 Changed font of table body DCD only 15.0-17 Changed page from portrait to landscape DCD only 15.1-4 Removed the phrase (...less than 0.0088 failure per reactor year..) DCD only Removed the phrase (less than 7x10~' failure per reactor year) DCD only Changed phrase (...lcss than once per reactor year... ) to "very low" DCD only 15.1-5 Repired "less than once per 10,000 years" with "so low that it" DCD only 15.1-6 Changed "(S)" to "(s)" and added a space after MPaG. Update SSAR 15.1-8 Removed less than 7x10-5 failure per reactor year in next to last DCD only sentence Replaced "less than 0.0088 times per year" with "very low frequency" DCD only ".mlaced "less than once per 10,000 years" with " extremely low" DCD only 15.1-20 Deined up figure DCD only 15.2-1 Deleted "less than 7x 10~' failures per reactor year" DCD only 15.2-1 Deleted "(0.0088 failures per reactor year)" DCD only 15.2-2 Replaced "(less than one failure every 11 years)" DCD only 15.2-5 Removed probability numbers 4 places DCD only 15.2-7 Removed white space DCD only 15.2-9 Modified paragraph and removed probability numbers 4 places DCD only 15.2-26 Unitalicized references DCD only 15.2-36 Cleaned up figure DCD only 15.3-5 Replaced "(less than 7x 10-5 failures per year)" with "very low" DCD only l SSAR-36 i ) I

1 Alignment of SSAR with DCD DCD Section/Pg Difference Action 15.3-5 Replaced "about 0.0088 failures per reactor year" with "very low" DCD only 15.4-8 Replaced "(less than 7x10-5 failures per reactor year)" with "very DCD only low" 15.4-8 Replaced "About 0.0088 failure per reactor year" with "very low" DCD only 15.4-11 Replaced numerical value of probability with " expected frequency is DCD only low" 15.4-13 Removed probability numbers (3 places) DCD only 15.4-17 Changed " Deleted" to "Not Used" DCD only i 15.6-7 Changed "12,868Kg" to "12,870Kg" and "21,949Kg" to "21,953" Update SSAR 15.6-17 Changed "the SSAR" to " Tier 2" DCD only 15.6-22 Removed deleted paragraph 15.6.7.2 DCD only 15.6-22, 23 Unitalicized references DCD only 15.6-26 Changed "55" to 55.5" Update SSAR 15.6-27 For item I.C., changed to Subsection 15.6.4.5. For item II.A, Update SSAR changed " Isolation valve closure time" to "MSiv closure time (break until fully closed). Changed "5.0s" to "5.5s" for MSIV clesure time. 15.6-30 Changed "12" to "2" under item iE particulate. Update SSAR 15.7-11 Unitalicized references DCD only 15.7-14 Changed " Deleted" to "Not Used" DCD only 15A-1 Changed "the SSAR" to " Tier 2" DCC only 15A Unitalicized paragraph headings DCD only 15A-111 Changed " Deleted" to "Not Used" DCD only 15B-4 Unitalicized paragraph headings DCD only SSAR-37 i

Alignment of SSAR with DCD DCD Section/Pg Difference Action 15B-17-2 Rewrote introduction to more firmly reference chapter 19 and deleted Update SSAR subsections 158.4.1 through 15B.4.4.2 and Figure 15B-8 15C-1/2 Changed " Deleted" to "Not Used" DCD only 15D-1 Changed " valve" to "value" in last sentence of first paragraph of Update SSAR subsection 15D.2 15D-2 Removed "(processor flow rate = 10%)" DCD only 15D-2 Revised text to eliminate probability DCD only 15D-3,15D-5-8 Eliminated figure / table contents and refer to SSAR DCD only 15E Unitalicized paragraph headings DCD only 15E-10 Unitalicized references DCD only 15E-15 Replaced "Kg/cm'g" with "MPaG" all places Update SSAR 15E-33 Cleaned up figure DCD only 15F-1 Unitalicized paragraph heading DCD only Chapter 16 Throughout The header and footer on each page are changed as follows: The GE DCD only document number in the header from the SSAR,23A6100 Rev. x, is deleted. The SSAR amendment number in the footer is replaced with "Rev. O, Design Control Document / Tier 2". Where the phrase "of the SSAR" is used to describe information in the DCD only SSAR, it is replaced with the phrase "of the DCD Tier 2". 4.0 Where the phrase "of the SSAR" is used to describe the applicant's DCD only 5.0 SSAR,it is replaced with the phrase "of the FSAR". Throughout Where the phrase "in the SSAR, Chapter (or Section) x" is used to DCD only point to the section of the SSAR,it is replaced with the phrase "in DCD Tier 2 Chapter (or Section) x". SSAR-38

4 Alignment of SSAR with DCD DCD Section/Pg ~ Difference Action Where the phrase "ABWR SSAR analysis" is used to describe the DCD only safety analyses in the SSAR, it is replaced with the phrase "ABWR safety analysis". i Where the phrase " transient or accident analysis in the ABWR SSAR" DCD only is used with no specific chapter or section reference, it is replaced with the phrase " transient or accident analysis for the ABWR". 4 B 3.8 Where the phrase " described in the SSAR" is used to refer to Chapter DCD only 8 of the SSAR, it is replaced with the phrase " described in DCD Tier i 2, Chapter 8". Where the phrase " requirement of Section x of the SSAR" is used to DCD only refer to certain requirement specified in the SSAR, it is replaced with the phrase " requirements of DCD Tier 2, Section x". i 3.3-1, -2 Numbering of Required Action for Condition A of LCO 3.3.1.1 Update SSAR "A.2.1" changed to "A.2.1.1", "A.2.2" changed to "A.2.1.2", i "A.2.3" changed to "A.2.2.1", and "A.2.4" changed to "A.2.2.2". 3.3-1, 3, 5, 6, 18, 19, 21, The Logical Connectors (AND, OR) were aligned to be consistent Update SSAR 28,29,47,48,53,68, with the convention defined in Section 1.2, Logical Connectors and 69 3.3-42 Changed unit of SR 3.3.2.1.3 from "HZ" to " cps". Update SSAR 3.5-2, Numbering of Required Action for Condition C of LCO 3.5.1 was Update SSAR changed from "C. I.1" to "C.I.l.1", "C.I.2" changed to "C.I.l.2", 4 j "C.2" changed to "C.I.2", and "C.3" changed to "C.2". l. 3.6-41 Logical connector AND in Required Action for Condition D of LCO Update SSAR 3.6.4.3 was re-aligned. 2 3.7-4 Logical AND for Required Action for Condition B of LCO 3.7.2 was Update SSAR added. 3.7-3, Changed UHS temperature from "37.8 C" to "35 C". Update SSAR 3.7-8, l 1 SSAR-39 1 . m

. - - _ _ = 1 Alignment of SSAR with DCD ? i j DCD Section/Pg Difference Action

j B 3.3-51, -54 In Item 19, Main Steam Pressure-Low, Applicable Safety Analysis, Update SSAR

] LCO, and Applicability, the use of the temi"100 F/ hour"is changed to "55 C/h"; the use of the term "785 psig" is changed to ] "5.4i MPaG". In Item 22, Main Steam Tunnel Temperature-Iligh, i the term "[25] gpm" is changed to "[95] Umin". B3.3-146 From third line in last paragraph removed "one bypassed channel in Update SSAR each division and" B 3.3-167 In item 3, SB&PC Reactor Steam Dome Pressure-fligh, Applicable Update SSAR 2 1 Safety Analysis, LCO, and Applicability, the term "1500 psig"is changed to "10.34 MPaG". B 3.3-237 In Background section, the term "I35 psig" is changed to "0.93 Update SSAR 4 M pag". B3.5-9 Changed middle heading for revised numbering on page 3.5-2. Update SSAR i B3.7-4 Changed UllS temperature from "37.8 C" to "35 C". Update SSAR Chapter 17 17.0-TOC Removed blank spaces throughout DCD only 17.0-i Added listing for 17.0.1.1 Update SSAR 17.0-i Expanded listing for 17.3.11 and 17.3.13 Update SSAR 17.0-1 Deleted "of this Standard Safety Analysis Report" from first sentence. DCD only 17.1-5/6 Unitalicized references DCD only 17.3-5 Added period to last sentence of section DCD only 17.3.9 17.3-6 Changed "8.6 MPa" to "8.6 MPaG-Update SSAR SSAR-40

Alignment of SSAR with DCD DCD Section/Pg Difference Action Chapter 18 18.0-i Moved Appendices heading to top of following page DCD only I 8.4-1 I Unitalicized text DCD only 18B-1 Unitalicized text in footnote DCD only 18C-8 Page layout change DCD only 18E-1 Added italicized second paragraph and footnote. DCD only Added " Staff" after "NRC" in third line of second paragraph. DCD only 18E-1 Italicized entire sections and added footnote. DCD only thru 18E-5 18E-7 Italicized entire table and added footnote DCD only thru 18E-28 18E-23 Added item xiii (NUREG-0800) DCD only 4 18E-29 Italicized entire attachment and added footnote DCD only thru 18E-35 18E-36 thru 18E-40 Italicized entire tables and added footnote DCD only 18A.6-8,18F-5 Changed "SGTS(A)" to SGTS(B)", "SGTS(B)" to "SGTS(C)", Update SSAR 18F-6,18F-7 "FCS(A)" to "FCS(B)", and "FCS(B)" to "FCS(C)" 18F-10,18F-12 1811-7/8 Changed proprietary notice to reference SSAR DCD only Chapter 19 19-ii Changed " Deleted" to "Not Used" DCD only 19-iii Removed listing for 19.14 DCD only ) 19-iv Removed listing for 19D DCD only 1 SSAR-41 )

Alignment of SSAR with DCD 3 DCD Section/Pg Difference Action 19-vi Deleted Appendix 19P subsection listing Update SSAR 19-ix Removed listing for tables 19.3-7-19.3-9 DCD only 19-ix Removed listing for 19D tables DCD only 19-xi Removed listing forTable 19E.3-8 DCD only Removed listing for 19FA DCD only 19-xiii Removed listing for table 19P-1 thru 19P-7 DCD only 19-xv Removed listing for 19D tables DCD only 19-xxiv Changed Figures 191-1 thru 191-25 listing referencing SSAR DCD only 19-xxiv Changed " Deleted" to "Not Used" DCD only 19-xxiv 19Q figure listing replaced with reference to SSAR DCD only 19-xxiv 19QA figure listings replaced with reference to SSAR DCD only 19.1-2 Deleted numerical probabilities (4 places). Substituted word values (2 DCD only places). 19.1-2 Unitalicized references DCD only 19.2-1 and 19.2-2 Replaced "this SSAR" with " Tier 2" DCD only 19.2-4 Unitalicized references DCD only 19.2-8/9 Unitalicized references DCD only 19.3-1 Removed "two events per year. This total consists of one planned DCD only reactor shutdown and one transient which results in reactor scram. The expected number of planned shutdowns is" from the second paragraph. Removed "are the same as those used in the GESSARll PRA (Reference 19.3.3) and" from the third paragraph SSAR-42

Alignment of SSAR with DCD DCD Section/Pg Difference Action l 19.3-1 Deleted Subsections 19.3.1.2.1 through 19.3.1.2.3 and inserted DCD only statement "not part of DCD (refer to SSAR)". 19.3-1 Corrected spelling of " compiled" insection 19.3.1.2.1 SSAR only 19.3-6 Unitalicized references DCD only 1 19.3-12 Eliminated probability values in first paragraph. DCD only 3 19.3-18 Replaced "no more than 10%" with "a small percentage" in last DCD only j paragraph. l 19.3-20 Replaced "of 1.6E-7 per year" with "is extremely small". DCD only f 19.3-22 Unitalicized references DCD only 19.3-23,19.3-29 thru Deleted frequencies and added footnote referring to SSAR. DCD only l 19.3-31 l 19.3-31 Deleted tables from DCD DCD only J j 19.3-33 Deleted body of figure and added footnote referring to SSAR. DCD only i 19.4-3 Removed probabilities in three places and inserted word values in DCD only two places. 19.4-4 Unitalicized references DCD only 19.4-5 Removed "of the SSAR" two places. DCD only 19.4-11 Removed last two sentences of second paragraph. DCD only 19.4-12 Eliminated two probability values in last paragraph. DCD only. 19.4-12 and 19.4-13 Eliminated six probability values. DCD only 19.4-13 Replaced "10-7 per year" with "very small". DCD only 19.5-1 Replaced "LPCl" with "RHR". Update SSAR l SSAR-43

Alignment of SSAR with DCD DCD Section/Pg Difference Action 19.5-3/4 Deleted " Examining the data in Table 19.3-6, the CCFP PI is 0.007. DCD only Therefore," from the fourth paragraph. 19.6-1 Eliminated probability values in 5 pixes. DCD only 19.6-3 Eliminated probability values in 2 places in she next to last paragraph. DCD only 19.6-4 thru 19.6-5 Eliminated probability values in ten places. DCD only 19.6-6 Unitalicized references DCD only 19.7-3 Replaced two numerical probabilities with word values. DCD only 19.7-10 Unitalicized reference DCD only 19.8-1 Replaced "the Certified Design Material (Section 14.3)" with " Tier 1". DCD only inserted "important" in front of " features are addressed by ITAAC...". Update SSAR 19.8-2 thru 19.8-23 Eliminated all probability values DCD only 19.8-24 Changed "Section" to " Attachment" and deleted "of the ABWR DCD only SSAR" under vessel depressurization". 19.8-35 Change "(2.15.210)" to "(2.15.10" under blowout panels. Update SSAR 19.8-41/42 Changed "2% per 100F" to "2% per 55.6 C" Update SSAR 19.9-6 Unitalicized References DCD only 19.9-7 Replaced "(i.e., less than one foot) and also prevent accumulation in DCD only one area flowing to "with in" under item (3) (b). 19.9-7 Removed "with an unavailability of IE-3 per demand or less". DCD only 19.10-3 Deleted second sentence. DCD only 19.10-3 and 19.10-4 Deleted "as 0.99" in second sentence, and deleted from third sentence DCD only on. SSAR-44

Alignment of SSAR with DCD DCD Section/Pg Difference Action 19.14 Removed section 19.14 DCD only 19A-1 Replaced "SSAR" with " Tier 2" in 2 places. DCD only 19A-1 Unitalicized references throughout DCD only 19A-21 thru 19A-23/24 Changed "SSAR" to " Tier 2" in right hand column DCD only 19B Changed "SS AR" to " Tier 2" throughout. DCD only Unitalicized references throughout DCD only Unitalicized headings throughout 19B-7 Removed extra entry for II.K.3(30) Update SSAR 19B-9 Removed " Deleted" sections DCD only 19B-77 Changed "2.3E+0.4 Kg (23 Tonnes)" to "2.26+05 N". Update SSAR 19B-108 Removed date from ACI 349,2 places and from ASME IIIin Update SSAR 198-110 Subsection 19B.2.61 198-119 Removed "For the SSAR" DCD only 19C-1/2 Replaced " Safeguards information provided under separate cover-DCD only with '"I'his section is not part of the DCD (refer to SSAR)." 19D-1/2 Removed entire Appendix 19D and replaced with "This section not DCD only part of the DCD (refer to SSAR)." 19E-vi Removed table 19E.3-8 DCD only 19E-xvi Removed Figure 19E.3-2 DCD only 19E.1-1/2 Deleted "primarily" in front of the word deterministic in the first line Update SSAR 19E.2-5 Changed " Deleted" to "Not Used" DCD only Removed " deleted" items l DCDonly SSAR-45 1

Alignment of SSAR with DCD I DCD Section/Pg Difference Action i 19E.2-11 thru Modified statement pertaining to probabilities. DCD only 19.E.2-13 19E.2-15 Replaced "LPCl" with "LPFL". Update SSAR 19E.2-19 19E.2-19 Deleted "of the SSAR" DCD only 19.E.2-22 Added " exceed" in front of "0.46 MPa". Update SSAR 19E.2-25 Modified second sentence to eliminate failure rate and melded the DCD only second and third sentence for clarification. 19E.2 Eliminated probability values and replaced them with word values DCD only throughout. 19E.2-87 Unitalicized references DCD only 19E.2-101 Deleted "the ABWR SSAR" from the first sentence. DCD only 19E.2-108 Replaced "no" with "early" in second sentence. Update SSAR 19E.2-154-157 Unitalicized references DCD only 19E.2-158 Extra page added with statement " In order to maintain consistency DCD only with the SSAR, this page has been intentionally left blank" 19E.2-188 Cleaned up figure DCD only 19E.2-259 Eliminated probabilities and added note " probabilities not part of DCD only thru DCD (refer to SSAR)". 19E.2-274 19E.3-1 Removed information from body of figures and added note "Not part DCD only of DCD (refer to SSAR)". 19E.3-3 Replaced "98.6%" with "a very large percentage" in second DCD only paragraph. 19E.3-5 Unitalicized references DCD only SSAR-46

Aligmnent of SSAR with DCD DCD Section/Pg Difference Action 19E.3-3 Replaced "the SSAR" with " Tier 2" in first paragraph. DCD only 19E.3-10 Removed table 19E.3-8 DCD only 19E.3-3 Removed probabilities and added note "Probabilit!::s not part of DCD DCD only 19E.3-9 (refer to SSAR)". 19E.3-10 j 19E.3-11 Removed body of figure and added note " Figure is not part of DCD DCD only (refer to SSAR)". I 19E.3-12 Removed Figure 19E.3-2 DCD only 19EA Removed numerical probabilities and, where applicable, replaced DCD only with word values throughout. I 19EA-29 Unitalicized references DCD only i 19EA-32 thm Deleted body of figures and added note " Figures not part of DCD DCD only i 19EA-37,19EA-39 (refer to SSAR)". 19EA-40,19EA-45 19EA46 4 19EB-2,19EB-3 Replaced numerical probabilities with word values. DCD only 19EC-4 Unitalicized References DCD only 19EC-4 Removed probabilities and added note " Probabilities not part of DCD DCD only (refer to SSAR)". 19EC-5 Removed numerical probabilities and, where applicable, replaced DCD only thm with word values. 19EC-14 19EC-26 Unitalicized references DCD only 19EC-29,19EC-30 Removed body of figures and added note " Probabilities not part of DCD only 19EC-36 DCD (refer to SS AR)". I 4 SSAR-47 i

Alignment of SSAR with DCD DCD Section/Pg Difference Action 19ED-26,27 Unitalicized references DCD only 19EE-3,19EE-5 Removed vacuum breaker related probabilities DCD only 19EE-6 19EE-11,19EE-12 Replaced numerical probabilities with word values. DCD only 19EE-13 19EE-13 Unitalicized references DCD only 19EE-17 Removed probabilities and added note " Probabilities not part of DCD DCD only (refer to SSAR)". 19EE-16 Removed body of figures and added note " Probabilities not part of DCD only 19EE-17/18 DCD (Refer to SSAR)". 19F-16,17 Unitalicized references DCD only 19F Cleaned up several figures DCD only Figures 19FA-l/2 Removed attachment 19FA and added note "This attachment is not DCD only j part of the DCD (refer to SSAR)." f 19G-l/2 Changed " Deleted" to "Not Used" DCD only 1911-4 Removed "of 3G (Table 19H-1)" DCD only 19H-14 Deleted last sentence of first paragraph. DCD only 19H-15 Deleted last sentence oflast paragraph and last sentence of fourth to DCD only - last paragraph. i 19H-17 Changed "the SSAR" to " Tier 2" and "ITAAC" to " Tier 1". DCD only 19H-20, 21 Unitalicized references DCD only 1911-23 Changed " probability" to " fragility" in footnote I and modified DCD only footnote 5 to eliminate specific values. SSAR-48

Alignment of SSAR with DCD DCD Section/Pg Difference ~ Action 1911-24 Removed fragilities and added note " Fragility not part of DCD. DCD only thru Refer to SSAR". 19H-32 19I-2, 191-3 Removed fragilities and corresponding probabilities. DCD only 191-4, 19I-5 191-8, 191-9 191-10 191-10 Unitalicized references DCD only 191-11, 191-12 Removed fragilities and HCLPF values from table and extended note DCD only 191-13 to read " Fragilities and HCLPF values are not part of DCD (refer to SSAR)". 191-14 Removed body of tables and added note "This table is not part of DCD only DCD (refer to SSAR)". 191-15 Fragilities and HCLPF values deleted from table and added note DCD only " Fragilities and HCLPF values are not part of DCD (refer to SSAR)." 19I-16 Body of table deleted and added note "This table is not part of DCD DCD only (refer to SSAR)". 191-17/18 Deleted figures and added note " Figures DCD only 19I-1 through 191-25 are not part of DCD (refer to SSAR)". 193-l/2 Changed " Deleted" to "Not Used" DCD only 19K-2,19K-5 Replaced numerical probability valves with word valves. DCD only 19K-8,19K-12 19K-17 19K-17,18 Unitalicized references DCD only 19K-19 thru Removed numerical values from tables and added note "Not part of DCD only 19K-21 DCD (refer to SSAR)" SSAR-49

Alignment of SSAR with DCD DCD Section/Pg ~ Difference Action 19K-22 thru Removed numerical values in right hand column and added note "Not DCD only 19K-31/32 part of DCD (refer to SSAR)". 19L-1 Replaced "the ABWR Safety Analysis Report (SSAR)" with " Tier 7-DCD only 19L-2 Replaced numerical probability value with word value. DCD only 19L-3 Removed "SSAR". DCD only 19L-8 Removed last sentence from item (3). DCD only 19L-8 Removed probability statement in last paragraph. DCD only 19L-8 Changed " third" to "second" in first item (1). Update SSAR 19L-20 Changed "one" to "two" diesel generations at end of first paragraph Update SSAR and deleted "one" under item (b). 19L-21 Deleted probabilities in second paragraphs. DCD only 19L-21 In item (b) changed " Failure of one diesel generator, or" to " Failure Update SSAR of diesel generators, or" 19L-21/22 Deleted "SSAR". DCD only 19L-23 Replaced numerical values of probabilities with word values. DCD only 19L-24 19L-26 Unitalicized References DCD only 19M-1,19M-2 Replaced numerical probability values with word values. DCD only 19M-3,19M-7. 19M-8 19M-1 Changed "1.0E-06 per year" to "an acceptably small criterion". DCD only 19M-9 Removed frequencies and added note "Not part of DCD (refer to DCD only 19M-10 SSAR)". SSAR-50

_ _, _ _ _.. _ _ - _ _ _ - ~ _. _ _ _... _ _.. Alignment of SSAR with DCD DCD Section/Pg ~ Difference Action 19M-10,19M-11 Replaced numerical values of probabilities with word values. DCD only i 19M-12 l 19M-12 Unitalicized references DCD only i 19M-13,19M-33 Removed frequencies and added note "Not part of DCD (refer to DCD only thru SSAR)". j 19M-35 19M-16 Deleted body of tables and added note "Not part of DCD (refer to DCD only thru SSAR)". 19M-33 19M-38 thru Deleted body of figures and added note "Not a past of DCD (refer to DCD only 19M-48 SSAR)". 19N-4 Unitalicized text DCD only 19N-1,19N-12 Removed numerical probabilities. DCD only 19N-13 19N-15,19N-17 Repixed numerical probabilities with word values. DCD only 19N-18 I 19N-19 Unitalicized references DCD only i 19P-l/2 Removed Appendix 19P in its entirety from the DCD and added note DCD only "This section is not part of the DCD (Refer to Attachment A of the t Technical Support Document for the ABWR)". Attachment A of the Technicat Support Document for the ABWR is not incorporated by reference in the DCD. I Removed body of Appendix 19P in its entirety from the SSAR and SSAR only added note. 19Q-2 in last paragraph replaced "the SSAR" with " Tier 2" and replaced DCD only "the Inspections, Test, Analysis, and Acceptance Criteria (ITAAC Requirement)" with " Tier 1". I i i SSAR-51 1 .-._...---.--.--___.____------..__-...,__--_-------,vn,~ v .n,-

Alignment of SSAR with DCD DCD Section/Pg Difference Action 19Q Replaced numerical probability values with word values throughout. DCD only 3 19Q-39 Unitalicized references DCD only 19Q-45 Removed unavailability values from table and added note "Not a part DCD only - of DCD (refer to SSAR)." l 19Q-57 Removed all figures and replaced with note " Figures 19Q-1 through DCD only thru 19Q-19 are not part of DCD (refer to SSAR)". 19Q-75n6 l 19QA-1 Removed all figures and replaced with note " Figures 19A-la through DCD only thru 19QA-20 ck are not part of DCD (refer to SSAR)". 19QA-412 19QB-4 Unitalicized references DCD only 19QB-5,19QB-6 Removed probabilities and added note "Not past of DCD (refer to DCD only SSAR)". I 19QC-1 Unitalicized references DCD only 19QC-29 Removed "ABWR" in fifth column under Susquehanna 1 entry. Update SSAR 19R-1,19R-2 Replaced numerical values of probability with word values. DCD only 19R-3 19R-7 Unitalicized references DCD only j 19R-4 Replaced "SSAR" with " Tier 2". DCD only 19R-24 19R-9 Replaced "2 hours" with "several hours" in fourth paragraph. DCD only 19R-21,19R-22 Replaced numerical probabilities with word values. DCD only 19R-25,19R-27 j 19R-28,19R-29 19R-30,19R-31 SSAR-52

Alignment of SSAR with DCD DCD Secnon/Pg Difference Action ~ I 19R-31 Deleted reliability goals and added note "Not a part of DCD (refer to DCD only SSAR)". 19R-33 Changed"(200,00 gal)" to "(200,000 gal)" under feedwater. Update SSAR 19R-35 Frequency / probability delete:d and added note "Not a part of DCD DCD only thru 19R-37 (refer to SSAR)". ~ 19R-47 thru 19R-53/54 Removed body of figures and added note "Not a part of DCD (refer DCD only to SSAR)". Chapter 20 Unitalici7ed text throughout DCD only 20.1-1 Added new pai;;mnh on reldonship of SSAR and Tier 2 " names" DCD only 1 in Chapter 20. 20.1-32, 33 Removed extra space DCD only 20.3.3-60 Cleaned up image DCD only 20.3.2-62 Cleaned up image DCD011y 20.3.3-24 Changed "nei-ct" to "Not Used" DCD only' 20.3.4-38, 39 Removec aom DCD DCD only 4 1 20.3.6-27 Removed from DCD DCD ordy 20.3.8-37 Italicized item (1) and added footnote. DCD only ~ 20.3.8-51 and Italicized third and last paragraphs of response and added footnotes. DCD only 20.3.d-52 20.3.8-96 Changed " Deleted" to "Not Used" DCD only { i 1 i i SSAR-53 a ._._------__.______-,.--==w

Alignment of SSAR with DCD I DCD Section/Pg Difference Action i 20.3.9-1 thru Deleted responses and added " Response to Chapter 19" questions not DCD only i 20.3.9-15/16 part of DCD (see SSAR Subsection 20.3.9)". 20.3.11-10 thru Deleted responses and added " Response to Chapter 19 questions not DCD only 20.3.11-11/12 part of DCD (See SSAR Subsection 20.3.11)". I 20.3.12-1 thru 20.3.12-Deleted msponses and added " Response to Chapter 19 questions not DCD only 9/10 part of DCD (see SSAR Subsection 20.3.12)". 20.3.12-5 Removed event / frequency table from end of response. DCD only 1 20.3.14-15 Unitalicized text in footnote DCD only 20.3.14-29 thru Deleted responses and added " Response to Chapter 19 questions not DCD only 20.3.14-32 part of DCD (see SSAR Subsection 20.3.14)". { 20.3.14-33 Cleaned up ligure DCD only 20.3.15-37 Changed notation " Response to this question is provided under DCD only thru separate cover" to " Safeguards Information not part of DCD (see 20.3.15-39 SSAR Subsection 20.3.15)". 4 [ 20.3.16-30 Removed extra space DCD only l 20.4-1 Unitalicized references DCD only Chapter 21 i Chap 21 TOC Changed" Essential" to "R/B Safety-Related" in Title of Figure 9.4-4 Update SSAR 21-35 and 21-26 Changed figures 1.2-25 and 1,2-26 to show 3 TCW heat exchangers Update SSAR and pumps. 21-103 and 21-127 Italicized note 32 and 29, respectively and added footnotes in DCD only figures 5.4-10 and 6.3 'i. 21-516 Removed RCW from lower right-hand of figure 9.2-1. Update SSAR 21-543, 21-544 Replxed " Essential" with " Safety-Related" in title of figure 9.4-4. Update SSAR 21-545 SSAR-54

i Attachmtnt 3 ABWR Certified Design Material Rev. 7 Page Change Instruction The following pages have been changed, please make the changes in your copy of the CDM. Pages are listed below as page pairs (front and back). Remove Pages Add Pages Remove Pages Add Pages v/vi v/vi i 2.7.1-3, 4 2.7.1-3, 4 i 2.8.1-1/2 2.8.1-1/2 t 2.8.3-1/2 2.8.3-1/2 I 2.8.4-1, 2 2.8.4-1, 2 2.12.1 1,2 2.12.1-1,2 2.12.14-1,2 2.12.14-1,2 3, 4 3, 4 2.14.6-5/6 2.14.65/6 2.15.5-7,8 2.15.5-7, 8 23,24 23,24 2.15.10-9,10 2.15.10-9,10 5.0-1, 2 5.0-1, 2 l i (1)

ABWR Standard Safety Analysis Report Rev. 8, Amendment 36-Page Change Instruction . The following pages have been changed, please make the changes in your copy of the SSAR. Pages are listed below as page pairs (front and back), except Chapter 16, which is single-sided pages only. Remove Pages Add Pages Remove Pages Add Pages Replace the cover sheet in each text volume 3.8-57,58 57,58 TOC Each Text Volume 3.9-27,28 3.9-27,28 1, ii i, il 29,30 29,30 35,36 35,36 Chapter 1 55,56 55,56 1.0-i, ii 1.0-i, ii 61,62 61,62 65,66 65,66 1.2-25,26 1.2-25,26 83,84 83,84 27,28 27,28 3.1 S13, 14 3.13 13,14 1.61,2 1.61,2 3A-3, 4 3A-3, 4 1.7-5, 6 1.7-5,6 85,86 85,86 23,24 23,24 295,296 295,296 1.8-11,12 1.8-11,12 3E-43, 44 SE-43, 44 27,28 27,28 35,36 35,36 3G-13,14 3G-13,14 39,40 39,40 1.841 thru 1.8-41 thru 3H.0-i, ii 3H.0-i, ii 1.8-48 1.8-48 51,52 51,52 3H.1-3, 4 3H.1-3, 4 5, 6 5, 6 Chapter 2 7, 8 7, 8 2.0-1, 2 2.01,2 13,14 13,14 2.31,2 2.31,2 5, 6 5, 6 3H.2-1, 2 3H.2-1, 2 5, 6 5, 6 Chapter 3 11,12 SH.2-11,12 3.1-23,24 3.1 23,24 29,30 29,30 3.3-3,4 3.3-3, 4 SH.3-1, 2 SH.3-1, 2 3, 4 3, 4 3.4-15,16 3.4-15,16 5, 6 5, 6 29,30 29,30 3.5-7, 8 3.5-7, 8 3.7-39,40 3.7-39,40 315,6 31-5, 6 7, 8 7, 8 3.8-33,34 3.8-33,34 35,36 35,36 Chapter 4 41,42 41,42 4,25,6 4.2-5, 6 43,44 43,44 7, 8 7, 8 51,52 51,52 53,54 53,54 4,43,4 4.3-3, 4 1 (1)

e. ABWR Standard Safety Analysis Report Rev. 8, Amendment SG Page Change Instruction t . The following pages have been changed, please make the changes in your copy of the SSAR. Pages are listed below as page pairs (front and back), except Chapter 16, which is single-sided pages only. Remove Pages Add Pages Remove Pages Add Pages 27,28 27,28 4.617,18 4.417,18 33,34 33,34 21,22 21,22 35,36 35,36 23,24 23,24 61,62 61,62 l 25,26 25,26 63,64 63,64 l 67,68 67,68 4A-1, 2 4A-1, 2 H3,84 S3,84 237,238 23/,238 Chapter 5 i 5.0-i, ii 5.0-i, ii 6.3-29,30 6.3-29,30 41,42 41,42 5.1-5, 6 5.15,6 43,44 43,44 6.4-1,2 6.4-1,2 5.2-13,14 5.2-13,14 l 17,18 17,18 6.5-5, 6 6.5-5, 6 29,30 29,30 9,10 9,10 l 41,42 41,42 11,12 11,12 43,44 43,44 45,46 45,46 6.7-1, 2 6.71,2 i 49,50 49,50 7, 8 7, 8 51,52 5.2-51,52 ( 53,54 53,54 6A11,12 6A-11,12 l 5.S13,14 5.S3,14 6G5,6 6C5,6 5.4-1, 2 5.4-1, 2 Chapter 7 l 11,12 11,12 7,15,6 7.1-5, 6 15,16 15,16 23,24 23,24 7.2-11,12 7.2-11,12 27,28 27,28 29,30 29,30 7.Sl9,20 7.S19,20 33,34 33,34 95,96 95,96 35,36 35,36 65,66 65,66 7.5-5,6 7.5-5, 6 15,16 15,16 5A-1, 2 5A-1, 2 l 3, 4 3, 4 7.63,4 7.63,4 5, 6 5, 6 7, 8 7, 8 7, 8 7, 8 19,20 19,20 47,48 47,48 Chapter 6 6%ii 6.0-{ii. 7.7-27,28 7.7-27,28 m, av m, iv 41,42 41.42 6.2-13,14 6.2-13,14 7A-3, 4 7A-3, 4 I (2)

m_ i 1 l ABWR Standard Safety Analysis Report Rev. 8, Amendment 36-Page Change Instruction The following pages have been changed, please make the changes in your copy of the SSAR. Pages are listed below as page pairs (front and back), except Chapter 16, which is single-sided pages only. Remove Pages Add Pages Remove Pages Add Pages 7, 8 7, 8 l 7A-9,10 7A-9,10 9A.4 53,54 9A.4-53, 54 11,12 11,12 481,482 481,482 501,502 501,502 7B-1 thru 7B-1 diru 7B-6 71M Chapter 10 10.1-5,6 10.1-5, 6 7C 7,8 7C 7, 8 10.2-11,12 10.2 11,12 Chapter 8 8.S43,44 8.3-43,44 Chapter 11 61,62 61,62 11.0-iii, iv 11.0-iii, iv 8A-1, 2 8A-1,2 II 2-1,2 11.2 1,2 5, 6 5, 6 Chapter 9 9.0-vii, viii 9.0-vii, viii 11.5-3,4 11.S 3, 4 17,18 17,18 i 9.1-5, 6 9.1-5, 6 19,20 19,20 65,66 65,66 21,22 21,22 23,24 23,24 l 9.2-5, 6 - 9.2-5, 6 25,26 25,26 l 11,12 11,12 9.2-19 thru 9.2-19 thru Chapter 12 9.2-34 9.2-34 12.0-ix, x 12.0-ix, x 51,52 51,52 57,58 57,58 12.2-31,32 12.2-31,32 59,60 59,60 33,34 33,34 l 65,66 65,66 9.S5, 6 9.S5, 6 9,10 9,10 12.S19,20 12.S19,20 13,14 13,14 25,26 25,26 17,18 17,18 21,22 21,22 Chapter 14 23,24 23,24 14.2-139,140 14.2-139,140 33,34 33,34 171,172 171,172 l l 9.4-7, 8 9.4-7, 8 14.3-11,12 14.3-11,12 17,18 17,18 14.3-23 thru 14.3-23 thru l 23,24 23,24 14.3-32 14.S 32 27,28 27,28 51,52 51,52 39,40 39,40 59,60 59,60 9.5-23,24 9.5-2S,24 Chapter 15 67,68 67,68 15.0-xv, xvi 15.0-xv, xvi (3)

f ABWR Standard Safety Analysis Report Rev. 8, Amendment 36-Page Change Instruction The following pages have been changed, please make the changes in your copy of the SSAR. Pages are listed below as page pairs (front and back), except Chapter 16, which is single-sided pages only. i i Remove Pages Add Pages Remove Pages Add Pages 237 237 15.1-15,16 15.1-15,16 B3.5-9 B3.5-9 15.G7,8 15.G7,8 25,26 25,26 B3.7-4 B3.7-4 27,28 27,28 29,30 29,30 ChaDier I7 17.0-i, ii 17.0-1, il 15B 17,18 15B-17,18 19,20 19,20 17.3-5,6 17.3-5,6 41/42 41/42 Chapter 18 15D-1, 2 15D-1,2 18A.6-7, 8 18A.G7,8 15E-15,16 15E-15,16 18F-5 thru 18F-5 thru 18F-12 18F-12 Chapter 16 3.3-1 thru 3.31 thru Chapter 19 3.3-3 3.3-3 19-vii/viii 19-vii/viii 5 5 6 6 19.3-1,2 19.3-1,2 18 18 19 19 19.5-1,2 19.5-1,2 21 21 l 28 28 19.8-1,2 19.8-1,2 l 29 29 35,36 Sii, 36 42 42 41/42 41/42 l 47 47 48 48 191k7,8 19B-7, 8 l 53 53 77,78 77,78 68 68 107,108 107,108 69 69 109,110 109,110 3.5-2 3.5-2 19E.11/2 19E.1-1/2 3.G41 3.G41 19E.2-15,16 19E.2-15,16 19,20 19,20 3.7-3 3.7-3 21,22 21,22 4 4 107,108 107,108 8 8 19L-9,10 191,9,10 B3.3-51 B3.3-51 19,20 19,20 54 54 21,22 21,22 145 145 167 167 19P-1 thru 31/32 19P-1/2 (4)

. _ ~. ABWR Standard Safety Analysis Report Rev. 8, Amendment 36. Page Change Instruction The following pages have been changed, please make the changes in your copy of the SSAR. Pages are listed below as page pairs (front and back), except Chapter 16, which is single-sided pages only. Remove Pages Add Pages Remove Pages Add Pages 19QC 29,30 19QC-29,30 19R-33,34 19R-33,34 Chapter 21 TOC (Each Drawine Volume) TOC 4 TOC 4 1 21-35 21-35 21-36 21-36 21-516 21-516 21-543 21-543 21-544 21-544 21-545 21-545 (5)}}