$0$$L.lXs,w.cnn June 8,1994 Docket No.52-001 l
l Tom Boyce, Senior Project Manager Standardization Project Directorate Associate Directorate for Advanced Reactors and License Renewal Office of the Nuclear Reactor Regulation
Subject:
Submittal Supporting Accelerated ABWR Schedule - Codes and Standards
Dear Tom:
Enclosed is a SSAR markup indicating the applicable edition to UBC, AISI SG - 673 and NEMA FB1 to the ABWR SSAR. These changes will be included in the Amendment 35 modification package scheduled for distribution later this month.
l Please note that the applicable edition of Bechtel Report BC-TOP-3-A is Revision 3 (See Page 3.3-3, Reference 3.3-3).
Please provide a copy of this transmittal to Tom Cheng.
Sincerely, j
,) by
(
1 Jac-ox Advanced Reactor Programs j
cc:
Alan Beard GE)
Gary Ehlert GE)
Norman Fletcher DOE)
Joe Quirk GE) l 150C07 s.s[pb
'l l
PDR ADOCK 05200001 yv l7 A
23A6100 Rev. 3 ABWR stand:rdsaf:tyAulysis R:grt e
l Table 1.8-21 Industrial Codes and Standards
- Applicable to ABWR Code or j
Standard Number Year Title American Concrete Institute (ACl) l 211.1' 1981 Practice for Selecting Proportions for Normal, Heavy Weight, and Mass Concrete.
212 1981 Guide for Admixtures in Concrete 214 1977 Recommended Practice for Evaluation of Strength Test Results of Concrete l
301 1984 Specifications for Structural Concrete for Buildings t
304 1973 Practice for Measuring, Mixing, Transporting, and Placing of Concrete 305 1977 Recommended Practice for Hot Weather Concreting 306 1978 Recommended Practice for Cold Weather Concreting 307 1979 Specification for the Design and Construction of Reinforced.
Concrete Chimneys l
308' 1981 Practice for Curing Concrete 309 1972 Practice for Consolidation of Concrete 311,1R 1981 ACI Manual of Concrete inspection 311.4R 1981 Guide for Concrete inspection l
315' 1980 Details and Detailing of Concrete Reinforcement l
318' 1983 Building Code Requirements for Reinforced Concrete l
349 1980 Code Requirements for Nuclear Safety-Related Concrete f
Structures 359 (See ASME BPVC Section lil)
American Institute of Steel Construction (AISC) l N690t 1984 Specifications for the Design, Fabrication, and Erection of Steel Safety-Related Structures for Nuclear Facilities l
SG-673 1986 Cp;;i;Or. f:: $2 Dr@ ef Cold-Formed Steel Stru;tur:!
".',;,7,b;,; D4 3s y M ow.I Manual of Steel Construction Amencan 3ros an el Shet hs4s44W i
Conformance with Standard Review Plan and Applicability of Codes and Standards - Amendment 33 1.8 35
F 23A6100 Gev. 4 ABWR StandardSafetyAnalysis Report l
Table 1.8-21 Industrial Codes and Standards
- Applicable to ABWR (Continued)
Code or Standard i
Number Year Title i
S67.02-80 1980 Nuclear-Safety-Related Instrument Sensing Line Piping and Tubing Standards for Use in Nuclear Power Plants National Electrical Manufacturers Association (NEMA)
. AB1 1986
' Molded Case Circuit Breakers M
ICS li 1983 General Standards for Industrial Control i
ICS 2 1988 Standards for Industrial Control Devices, Controllers and Assemblies MG1 1987 Motors and Generators W C-5 (See ICEA S-61-402)
WC7 (See ICEA S-66-524)
WC 51 (See ICEA P-54-440)
- ^4 Suy*N FB 1 t9T7 Fd+ 9 f for ConclM cmd Cob \\ c Assowkhaf National Fire Protection Association (NFPA) t 10 1981 Portable Fire Extinguishers -Installation 10A 1973 Portable Fire Extinguishers - Maintenance and Use 11t 1988 Low Expansion Foam and Combined Agent Systems-Foam Extinguishing System i
12 1985 Carbon Dioxide Extinguishing Systems t
13 1985 Installation of Sprinklers Systems i
14 1986 Installation of Standpipe and Hose Systems 1st 1985 Standard for Water Spray Fixed Systems t
16 1991 Deluge Foam-Water Sprinkler and Foam-Water Spray Systems t
16A 1988 Recommended Practice for the Installation of Closed Head Foam-Water Sprinkler Systems 20' 1990 Standard for the Installation of Centrifugal Fire Pumps i
24 1984 Private Service Mains and their Appurtenances t
26 1988 Recommended Practice for the Supervision of Valves Controlling Water Supplies for Fire Protection 37' 1984 Stationary Combustion Engines and Gas Turbines 70t 1987 National Electrical Code-Handbook 1987 72t 1990 Protective Signaling Systems 1.84 Conformance with Standard Rem ew Plan and Applicability of Codes and Standards - Amendment 34
_.m
,_m..
~
23A6100 Gev. 4 l
.A&WR standardsareryAnalysis neport Table 1.8-21 Industrial Codes and Standards
- Applicable to ABWR (Continued) j
'I Code or Standard Number Year Title.
l UL-845 1988 Standard for Safety Motor Control Centers - Low Voltage Circuit Breakers Crane Manufacturers Association of America, Specification No. 70 Aluminum Construction Manual by Aluminum Association N CIG-01 Rev. 2 Visual Weld Acceptance Criteria for Structural Welding at Nuclear Power Plants USC t 9 91 Ve do<m bd dq Co de.
The listing of a code or standard does not necessarily mean that it is applicable in its entirety.
t Also an ANSI code (i.e. ANSI /ASME, ANSI /ANS, ANSI /IEEE etc.).
- ANSt, ANSl/ANS, ANSl/ASME, and ANSI /IEEE codes are included here. Other codes that approved by ANSI and another organization are listed under the latter.
f As modified by NRC accepted alternate positions to the related Regulatory Guide and identified in Table 2-1 of Reference 1 to Chapter 17.
t b
. Conformance with Standard Review Plan and Applicability of Codes and Standards - Amendment 34 1.847
l e'
23A6100 Rev. 3 ABWR ses:dards:fetyAn: lysis R:p:rt (10) Steel Structures Painting Council Standards (a) SSPGPA Shop, Field and Maintenance Painting (b) SSPGPA Measurement ofPaint Film Thickness with Magnetic Gages (c)
SSPC-SP Solvent Cleaning (d) SSPGSP White Metal Blast Cleaning (c) SSPGSP CommercialBlast Cleaning (l)
SSPGSP Near-White Blast Cleaning (l1) ACl-ASCE Committee 326-ShearandDiagonal Tension, ACIManualofConcrete Practice, Pan 2.
(12) Applicable ASTM Specifications for Materials and Standards.
(l3) AASHTO Standard Speaficationsfor Highway Bridgesfor tnick loading area.
3.8.4.2.2 Control Building Refer to Subsection 3.8.4.2.1.
Add NRC Rules and Regulations Title 10, Chapter 1, Code of Federal Regulations, Part i
73.2 and 73.55.
3.8.4.2.3 Radwaste Building Substructure The RWB Substructure shall be designed using the same codes and standards as the reactor building. Refer to Subsection 3.8.4.2.1 for a complete list.
In addition, the non-Seismic Category I reinforced concrete portion of the superstructure is designed according to the seismic provisions of the uniform building code.
3.8.4.2.4 Seismic Category l Cable Tray, Cable Tray Supports, Conduit and Conduit Supports (1) ANSI /AISGN690, Speafication for Design, Fabrication and Erection ofSteel Safety-Related StnicturesforNuclearFacility.
colol Farmaet skel om s) w so wal AlSI Scr673[7=l=:.v,,fv, i,',i kip :l N'jb,ad L: :, auurai 2=1.W (2)
Au s*If FS1 (3) p hDi. Fittings and Supportsfor Conduit and Cable Assemblies.
3.8.4.2.5 Seismic Category i HVAC Ducts and Supports (1) ASME/ ANSI AG 1, Code on Nuclear Air and Gas Treatment.
i 3.8-36 Seismic Category I Structures - Amendment 33
-