TABLE 2-2a
=_
E.
I. Hat c h Nuclear Fcysr P! ant UNIT 1 EFFLUENT AND WASTE DISPOSAL 5EMIANNUAL REPORT 1984 GASEQUS EFFLUENTS-ELEVATED RELEASE CONTINUOUS MODE BATCH MODE Nuc lides Released Unit Quarter Quarter Quarter Quarter 1
2 1
2 1.
Fission gases Xe-133 C1 2.58E+03 5.82E+02 0.00E+00 0.00E+00 Xe-131m C1 8.80E+00 4.97E+00 0.00E+00 0.00E+00 Kr-88 C1 1.45E+02 4.73E+02 0.00E+00 0.00E+00 Xe-133M C1 1.33E+02 1.06E+01 0.00E+00 0.00E+00 Xe-135 Ct 4.99E+02 9.88E+00 0.00E+00 0.00E+00 Kr-85M C1 9.24E+01 3.39E+02 0.00E+00 0.00E+00 I-131 Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Kr-87 C1 2.48E+01 6.05E+01 0.00E+00 0.00E+00 Xe-138 Ct 3.98E+00 1.30E+01 0.00E+00 0.00E+00 Xe-137 Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 H-13 C
1.20E+01 4.18E+01 0.00E+00 0.00E+00
'g Kr-85 Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Xe-135M Ci 5.62E+00 6.62E+00 0.00E+00 0.00E+00 I-133 ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Kr-89 C1 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1-135 Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Ar-41 m
Ci 3.62E+00 8.21E+00 0.00E+00 0.00E+00 Tot al for period Ci 3.50E+03 1.55E+03 0.00E+00 0.00E+00 1
2.
Iodines I-131 Ci 6.T6E-03 2.24E-03 0.00E+00 0.00E+00 I-133 C1 4.98E-04 6.75E-04 0.00E+00 0.00E+00 I-135 C1 2.07E-04 4.96E-04 0.00E+00 0.00E+00 Tot al for period Ci 7.4?E-03 3.41E-03 0.00E+00 0.00E+00
- 3. P art i c ul at e s 3r-89 Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 3r-90 Ct 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Ce-141 C1 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Cr-51 Ct 0.00E+00 1.48E-06 0.00E+00 0.00E+00 1-131 Ci 1.15E-05 7.06E-06 0.00E+00 0.00E+00 Sn-113 C1 0.00E+00 3.63E-08 0.00E+00 0.00E+00 Ba-140 C1 2.01E-05 6.80E-05 0.00E+00 0.00E+00 Cs-134 Ci
'.15E-07 6.45E-07 0.00E+00 0.00E+00 Cs-137 Ci 2.68E-06 2.30E-06 0.00E+00 0.00E+00 Ce-144 Ct 0.00E+00 9.24E-06 0.QDE+00 0.00E+00 2r-95 Ct 0.00E+00 0.00E+00 0.00E+10 0.00E+00 Hb-95 C1 0.00E+00 2.04E-07 0.00E+00 0.00E+00 l
Co-58 C1 0.00E+00 4.09E-08 0.00E+00 0.00E+00 I
Mn-54 Ct 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Fe-59 Ct 0.00E+00 2.08E-07 0.00E+00 0.00E+00 Co-60 Ci 1.62E-06 1.63E-06 0.00E+00 0.00E+00 La-140 C1 2.89E-05 1.56E-04 0.00E+00 0.00E+00 Tot al for perted Ci 6.55E-05 2.47E-04 0.00E+00 0.00E+00 8504100355 840914 PDR ADOCK 05000321 g
I R
_ 31
,k
//
Revised 9-14-84
i
- ~ j*
TABLE 2-2b E.
!*. H at c h Nuc l e ar Po er P l ant UNIT 2 EFFLUENT AND WASTE DISPOSAL SEMIANNUAL PEPORT 1984 GASEOUS EFFLUENTS-ELEVATED RELEASE CONTINUGUS MODE BATCH MODE Nuclides Released Unit Quarter Quarter Qu ar t e r Quarter
(
1 2
1 2
- 1. Fission gases 1
Xe-133 I
Ci 7.94E+02 0.00E+00 0.00E+00 0.00E+00 Xe-131m Ci 2.71E+00 0.00E+00 0.00E+00 0.00E+00 Kr-98 Ci 4.48E+01 0.00E+00 0.00E+00 0.00E+00 Xe-133M Ci 4.10E+01 0.00E+00 0.00E+00 0.00E+00 Xe-135 Ci 1.54E+02 0.00E+00 0.00E+00 0.00E+00 Kr-85M C1 2.85E+01 0.00E+00 0.00E+00 0.00E+00 1-131 Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 kr-87 Ci 7.66E+00 0.00E+00 0.00E+00 0.00E+00 Xe-138 C1 1.23E+00 0.00E+00 0.00E+00 0.00E+00 Xe-137 Ct 0.00E+00 0.00E+00 0.00E+00 0.00E+00 H-13 C1 3.70E+00 0.00E+00 0.00E+00 0.00E+00 Kr-85 Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00
. $)
Xe-135M Ci 1.73E+00 0.00E+00 0.00E+00 0.00E+00 I-133 Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Kr-89 Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 I-135 C1 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Ar-41 Ci 1.12E+00 0.00E+00 0.00E+00 0.00E+00 v
Tot al for period Ci 1.08E+03 0.00E+00 0.00E+00 0.00E+00 2.
Iodines I-131 C1 2.09E-03 0.00E+00 0.00E+00 0.00E+00 I-133 Ci 1.54E-04 0.00E+00 0.00E+00 0.00E+00 3
1-135 Ci 6.38E-05 0.00E+00 0.00E+00 0.00E+00 Tot al for period Ci 2.~30E-03 0.00E+00 0.00E+00 0.00E+00
- 3. Part icul at es
"""~
Sr-89 C1 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Se-90 Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Ce-141 Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Cc-51 Ct 0.00E+00 0.00E+00 0.00E+00 0.00E+00 I-131 Ci 3.56E-06 0.00E+00 0.00E+00 0.00E+00 Sn-113 Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Ba-140 Ci 6.21E-06 0.00E+00 0.00E+00 0.00E+00 Cs-134 Ci 2.21E-07 0.00E+00 0.00E+00 0.00E+00 Cs-137 Ci 3.25E-07 0.00E+00 0.00E+00 0.00E+00 Ce-144 C
O.00E+00 0.00E+00 0.00E+00 0.00E+00 2r-95 Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Nb-95 Ct 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Co-58 Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Mn-54 C1 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Fe-59 C1 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Co-60 Ct 5.00E-07 0.00E+00 0.00E+00 0.00E+00 L a-140 Ci S.90E-06 0.00E+00 0.00E+00 0.00E+00 Tot al for period Ci 2.02E-05 0.00E+00 0.00E+00 0.00E+00
_y2 -
Revised 9-14-84
v
- }
TABLE 2-2c m.
E.
!& Hatch Huc l e ar Power Plant $1TE EFFLUENT AND WASTE DISPOSAC SEMIANNUAL PEPORT 1934 CASEOUS EFFLUENTS-ELEVATED RELEASE CONTINUQUS MODE BATCH MODE Hucitdes Released Unit Quarter Quarter Quarter Quarter 1
2 1
2
- 1. Fission gases Xe-133 C1 3.37E+03 5.82E+02 0.00E+00 0.00E+00 Xe-131m C1 1.15E+01 4.97E+00 0.00E+00 0.00E+00 Kr-88 C1 1.90E+02 4.73E+02 0.00E+00 0.00E+ DOI xe-133M Ci 1.74E+02 1.06E+01 0.00E+00 0.00E+00 Xe-135 Ci 6.53E+02 9.88E+00 0.00E+00 0.00E+00 Kr-SSM C1 1.21E+02 3.39E+02 0.00E+00 0.00E+00 I-131 C1 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Kr-87 C1 3.25E+01 6.05E+01 0.00E+00 0.00E+00 Xe-138 Ci 5.21E+00 1.30E+01 0.00E+00 0.00E+00 Xe-137 Ct 0.00E+00 0.00E+00 0.00E+00 0.00E+00 N-13 Ct 1.57E+01 4.10E+01 0.00E+00 0.00E+00 Kr-85 Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00
,4 Xe-135M Ct 7.36E+00 6.62E+00 0.00E+00 0.00E+00 1-133 Ci 0.00E+00 0.00E+00 0.00E*00 0.00E+00 Kr-89 C1 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1-135 Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Ar-41 C1 4.74E+00 8.21E+00 0.00E+00 0.00E+00 0
Tot al for period Ci 4.59E+03 1.55E+03 0.00E+00 0.00E+00 2.
todines I-131 Ct 3.55E-03 2.24E-03 0.00E+00 0.00E+00 1-133 C1 6.51E-04 6.75E-04 0.00E+00 0.00E+00 I-135 C1 2.70E-04 4.96E-04 0.00E+00 0.00E+00 Tot al for period Ci 9.?7E-03 3.41E-03 0.00E*00 0.00E+00
- 3. P ar t i c u l at e s 3r-89 C1 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Sr-90 C1 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Ce-141 Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Cr-51 Ct 0.00E+00 1.40E-06 0 00E+00 0.00E+00 I-131 C1 1.51E-05 7.06E-06 0.00E+00 0.00E+00 Sn-113 Ci 0.00E+00 3.63E-08 0.00E+00 0.00E+00 Ba-140 Ct 2.63E-05 6.80E-05 0.00E+00 0.00E+00 Cs-134 Ct 9.36E-07 6.45E-07 0.00E+00 0.00E+00 Cs-137 C1 1.50E-06 2.30E-06 0.00E+00 0.00E+00 Ce-144 Ct 0.00E+00 9.24E-06 0.00E+00 0.00E+00 2r-95 Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Nb-95 C1 0.00E+00 2.04E-07 0.00E+00 0.00E+00 Co-58 Ct 0.00E*00 4.09E-03 0.00E+00 0.00E+00 Mn-54 Ct 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Fe-59 Ct 0.00Ef00 2.08E-07 0.00E+00 0.00E+00 Co-60 Ct 2.12E-06 1.63E-06 0.00E+00 0.00E+00 La-140 C1 3.73E-05 1.56E-04 0.00E+00 0.00E+00 Tot al for period Ci 8.57E-05 2.47E-04 0.00E+00 0.00E+00 Revised 9-14-84
- /