IlO GEORGIA POWER COMPANY t

E. I. HATCH NUCLEAR PLANT UNITS NO.1 & 2 i

ANNUAL REPORT PLANT RADIOACTIVE EFFLUENT RELEASES l

JANUARY 1,1996 THROUGH DECEMBER 31,1996 i

SECTION TITLE PAGE j

1.0 Liquid Effluents 1

I I

1.1 Regulatory Limits / Technical Specifications 1

l 1.1.1 Concentration Limits 1

4 l

l 1.1.2 Dose Limits

-1 l

1 1.2 Effluent Concentration Limit 1

1.3 Measurements and Approximations of Total 2

Radioactivity 1.4 Liquid Effluent Release Data 4

1.5 Radiologicalimpact on Man Due to Liquid Release 5

1.6 Abnormal Releases 5

1.7 Batch Releases 5

2.0 Gaseous Effluents 33 2.1 ODCM Specifications 33 2.1.1 Dose Rate Limit 33 O

I 9705060326 970430 ADOCK0500g1-DR

SECTION TITLE PAGE l

O 2.1.2 Air Dose Due to Noble Gas 33 2.1.3 Dose to Any Organ 33 2.1.4 Total Fuel Cycle Dose Commitment (40CFR190) 34 2.2 Release Points of Gaseous Effluents 34 2.3 Total Quantities of Radioactivity, Dose Rates 35 and Cumulative Doses 2.3.1 Fission and Activation Gas 35 2.3.2 Radiolodine, Tritium and Particulate Releases 35 2.3.3 Gross Alpha Release 36 2.4 Gaseous Effluent Release Data 37 i

2.4.1 Methodology 37 O

2.5 Radiological impact Due to Gaseous Releases 39 i

2.6 Abnormal Releases 39 3.0 Solid Waste 78 3.1 Regulatory Limits / Technical Specifications 78 3.1.1 Solid Radioactive Waste System 78 3.1.2 Reporting Requirements 78 3.1.3 Process Control Program (PCP) 78 3.2 Solid Waste Data 79 4.0 Changes to the Plant Hatch ODCM 84 5.0 Doses to Members of the Public inside The 84 Site Boundary

SECTION MLE PAGE 6.0 Major Changes to the Liquid, Gaseous and 93 Solid Radwaste Treatment Systems 7.0 Meteorological Data 93 8.0 Inoperable Liquid or Gaseous Effluent 93 Monitoring instrumentation l

9.0 Tanks Exceeding Curie Content Limits 94 i

O J

O m

I GEORGIA POWER COMPANY E. I. HATCH NUCLEAR PLANT UNITS NO.1 & 2 4

ANNUAL REPORT l

PLANY, RADIOACTIVE EFFLUENT RELEASES i

4 j

TABLE LIST OF TABLES PAGE 1-1 A Liquid Effluents - Summation of All Releases 6

Unit 1 (Quarters 1,2,3 and 4) j j

1-1 B Liquid Effluents - Summation of All Releases 8

Unit 2 (Quarters 1,2,3 and 4) l 1-1C Liquid Effluents - Summation of All Releases 10 Site (Quarters 1,2,3 and 4) l 1-2A Liquid Effluents - Unit 1 (Quarters '1, 2, 3 and 4) 12 i

l 1-2B Liquid Effluents - Unit 2 (Quarters 1,2,3 and 4) 16 1-2C Liquid Effluents - Site (Quarters 1,2,3 and 4) 20 1-3A Doses to a Member of The Public Due to Liquid 24 Releases Unit 1 (Quarters 1,2,3 and 4) i 1-3B Doses to a Meaber of The Public Due to Liquid 26 Releases Unit 2 (Quarters 1,2,3 and 4) 1 1-4A Liquid Effluents - Batch Release Summary 28 Unit 1 j

1-4B Liquid Effluents - Batch Release Summary 30 Unit 2 j

1-5 Minimum Detectable Concentration -

32 4 (

Liquid Sample Analysis

i i

TABLE LIST OF TABLES PAGE

O 2-1 A Gaseous Effluents - Summation of All 40 Releases - Unit 1 (Quarters 1,2,3 and 4) 2-1 B Gaseous Effluents - Summation of All 42 Releases -Unit 2 (Quarters 1,2,3 and 4) 2-1C Gaseous Effluents - Summation of All 44 Releases - Site (Quarters 1, 2, 3 and 4) 2-2A Gaseous Effluents Elevated Releases 46 Unit 1 (Quarters 1,2,3 and 4) 2-2B Gaseous Effluents - Elevated Releases 50 Unit 2 (Quarters 1,2,3 and 4) 2-2C Gaseous Effluents - Elevated Releases 54 Site (Quarters 1,2,3 and 4) i 2-3A Gaseous Effluents - Ground Level Release 58 Unit 1 (Quarters 1,2,3 and 4) 2-3B Gaseous Effluents - Ground Level Release 62 Unit 2 (Quarters 1,2,3 and 4) 2-3C Gaseous Effluents - Ground Level Release 65 Site (Quarters 1,2,3 and 4) 2-4A Air Doses Due to Gaseous Releases -

69 Unit 1 (Quarters 1,2,3 and 4) 24B Air Doses Due to Gaseous Releases-71 Unit 2 (Quarters 1,2,3 and 4) 2-5A Doses to a Member of the Public Due to 73 Radioiodine, Tritium, and Particulates in Gaseous Releases - Unit 1 (Quarters 1, 2, 3 and 4) 2-5B Doses to a Member of the Public Due to 75 Radiolodine, Tritium, and Particulates in Gaseous Releases - Unit 2 (Quarters 1,2, 3 and 4) 2-7 Minimum Detectable Concentration -

77 O

Gaseous Sample Analyses

..e

t i

TABLE LIST OF TABLES PAGE O

4 3-1 A,B Solid Waste and irradiated Fuel Shipments 80,82 i

4-1 Dose to A Member of the Public Due to Activities 85 Inside The Site Boundary a

1 i

4 i

l h

1 O

1

\\

h 1.0 Liquid Effluents 1.1 Regulatory Limits / Technical Specifications i

1.1.1 Concentration Limits The concentration of radioactive material released in liquid effluents to UNRESTRICTED AREAS shall be limited to the concentrations specified in 10 CFR Part 20, Appendix B, Table 11, Column 2, for radionuclides other than dissolved or entrained noble gases. For dissolved or entrained noble gases, the concentration shall be limited to 1.0E-4 microcuries/mi total activity.

1.1.2 Dose Limits The dose or dose commitment, to a MEMBER OF THE PUBLIC from radioactive materials in liquid effluents released from each unit to UNRESTRICTED AREAS, shall be limited:

a.

During any calendar quarter, to less than or equal to 1.5 mrems to the whole body and to less than or equal to 5 mrems to any organ, and b.

During any calendar year, to less than or equal to 3 mrems to the whole body and to less than or equal to 10 mrems to any organ.

1.2 Effluent Concentration Limit (ECL)

ECL values used in determining allowable liquid radwaste release i

rates and concentrations, for principal gamma emitters,1-131, tritium, Sr-89, Sr-90 and Fe-55, are taken from 10 CFR Part 20, Appendix B, Table 11, Column 2. A tolerance factor of up to 10 is utilized to allow flexibility in establishing practical monitor set points which can accommodate effluent releases at concentrations higher than the ECL values stated in 10 CFR 20, Appendix B, Table 11, Column 2.

For dissolved or entrained noble gases in liquid radwaste, the ECL is 1E-04 uCi/ml total activity.

For gross alpha in liquid redwaste, the ECL is 2.0E-09 uCi/ml.

Furthermore, for all the above radionuclides, or categories of radioactivity, the overall ECL fraction is determined in accordance with 10 CFR Part 20, Appendix B. m

l 1

]V The method utilizing the ECL fraction to determine release rates and liquid radwaste effluent radiation monitor set points is described in Subsection 1.3 of this report.

1.3 Measurements and Approximations of Total Radioactivity 3

Prior to the release of any tank containing liquid radwaste, following j

the required recirculations, samples are collected and analyzed in accordance with the Edwin I. Hatch Nuclear Plant Offsite Doso Calculation l

Manual (ODCM) Table 2-3. A sample from each tank planned for release is analyzed for principal gamma emitters,1-131, and dissolved and entrained noble gases, by gamma spectroscopy. Monthly and quarterly

)

composites are prepared for analysis by extracting aliquois from each i

sample taken from the tanks released. Liquid radwaste sample analyses are performed as follows:

j MEASUREMENT FREQUENCY METHOD d

1.

Gamma isotopic Each Batch Gamma Spe"roscopy with computc.. zed data reduction.

)

2.

Dissolved or entrained Each Batch Gamma Spectroscopy noble gases with computerized

)

j data reduction 3.

Tritium Monthly Distillation and Composite liquid scintillation 4

counting 4.

Gross Alpha Monthly Gas flow proportional Composite counting i

i 5.

Sr-89 & Sr 90 Quarterly Chemical separation Composite and gas flow proportional or scintillation counting l

6.

Fe-55 Quarterly Chemical separation Composite and liquid scintillation counting

}

1

!O

.2-

~

Gamma isotopic measurements are performed in-house using germanium detectors with a resolution of 2.0 kev or lower. The detectors are shielded by four inches of lead. A liquid radwaste sample is typically counted for 3000 seconds and a peak search of the resulting gamma ray spectrum is performed.

i Energy and net count data for all significant peaks are determined and a quantitative reduction or MDC calculation is performed to ensure that the MDC's are met for the nuclides specified in the ODCM Ch 10 (i.e., Mn-54, Fe-59, 3

l Co-58, Co-60, Zn-65, Mo-99, Cs-134, Cs-137, Ce-141 and Ce-144). The quantitative calculations, corrections for counting time, decay time, sample volume, sample geometry, detector efficiency, baseline counts, branching ratio and MDC calculations, are made based on the counts at the location in the i

spectrum where the peak for that radionuclide would be located, if present.

The maximum error associated with volume and flow measurements, based upon plant calibration practice, is estimated to be + or - 10%. The average error associated with counting is estimated to be less than + or - 15%.

Tritium, Gross Alpha, Sr-89, Sr-90 and Fe-55 are, in some cases, analyzed offsite.

The radionuclide concentrations determined by gamma spectroscopic analysis of samples taken from tanks planned for release, b eddition to the most current sample analysis results available for tritium, gross alpha, Sr-89, i

Sr-90 and Fe-55, are used along with the corresponding ECL values to determine the ECL fraction for these tanks. This ECL fraction is then used, with the appropriate safety factors, tolerance factors, and the expected dilution stream flow to calculate maximum permissible release rate and a liquid effluent monitor setpoint. The monitor setpoint is calculated to assure that the limits of the ODCM are not exceeded.

A monitor reading in excess of the calculated setpoint will result in an automatic termination of the liquid radwaste discharge. Liquid effluent discharge is also automatically terminated if the dilution stream flow rate falls below the minimum assured dilution flow rate used in the setpoint calculations and established as a setpoint on the dilution stream flow i

monitor.

i Radionuclide concentrations, safety factors, dilution stream flow r&e, and the liquid effluent radiation monitor calibration factor, are entered into the computer and a pre-release printout is generated. If the release is not permissible, appropriate warnings will be displayed on the computer i

screen. If the release is permissible, it is approved by the Chemistry Foreman on duty. The pertinent information is transferred manually from the prerelease printout to a one-page release permit, which is forwarded I

to Radwaste Operations. When the release is completed, the release permit 1

is retumed from Radwaste Operations to Chemistry with the actual release c

data provided. These data are input into the computer and a post-release printout is generated. The post release printout contains the actual release rates, the actual release concentrations and quantities, the actual dilution flow, and the calculated doses to an individual.

1.4 Liquid Effluent Release Data Regulatory Guide 1.21, Tables 2A and 2B are found in this report as Table 1-1 A, for Unit 1, Table 1-1B, for Unit 2 and Table I-1C, for the site; and Table 1-2A, for Unit 1,1-2B, for Unit 2, and Table 1-2C, for the site. Typical liquid minimum detectable concentrations (MDC's) used for analyses are found in Table 1-5.

The 10 CFR 50.59 Evaluation for the release of Unit One RHR Service Water:

Release of Contamainated Water can be found in Appendix A of this report.

The values for the four categories of Tables 1-1 A, and 1-1B, and 1-1C, are calculated and the Tables completed as follows:

1.

Fission and activation products - The total release values (not including A

tritium, gases, and alpha) are comprised of the sum of the measured V

individual radionuclide activities. This sum is for each batch released to the river for the respective quarter.

2.

Tritium - The measured tritium concentrations in the monthly composite samples are used to calculate the total release and average diluted concentration during each period.

3.

Dissolved and entrained gases - Concentrations of dissolved and entrained gases in liquid effluents are measured by germanium spectroscopy using a one liter sample from each liquid radwaste batch. The measured concentrations are used to calculate the total release and the average diluted concentration during the period. Radioisotopes of iodine in any form are also determined during the isotopic analysis for each batch; therefore, a separate analysis for possible gaseous forms is not performed because it would not provide additional information, 4.

Gross alpha radioactivity - The measured gross alpha concentrations in the monthly composite samples are used to calculate the total release of alpha radioactivity, Afv}

4 i

i

! O 4=

a ai ' ai= ' i-a =* " = " a" * a='d a '

Doses to an individual due to radioactivity in liquid emuent were calculated l

in accordance with the Offsite Dose Calculation Manual. Results are presented in Table 1-3A for Unit 1, and 1-3B for Unit 2, for all four quarters.

i s

1.6 Abnormal Releases There were no abnormal liquid releases for this reporting period.

1.7 Batch Releases Batch Release information for Units 1 and 2 is summarized in the following tables:

]

Unit 1 Liquid Batch Releases: Table 1-4A Unit 2 Liquid Batch Releases: Table 1-4B O

O

TABLE 1 1A E. I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -

1996 Liquid Effluents. Summation of All Release's Unit: 1 Starting :

1-Jan-1996 Ending : 30-Jun-1996 TYPE OF EFFLUENT UNITS QUARTER 1 QUARTER 2 EST. TOT ERROR %

A.

FISSION & ACTIVATION PRODUCTS

1. TOTAL RELEASE (NOT INCLUDING TRITIUM, GASES, ALPHA)

CURIES 4.54E-02 1.12E-01 4.70E+01

2. AVERAGE DILUTED CONCENTRATION DURING PERIOD uCi/ML 3.88E-08 1.04E-07
3. PERCENT OF APPLICABLE LIMIT B. TRITIUM
1. TOTAL RELEASE CURIES 1.06E+01 3.12E+00 3.'70E+01
2. AVERAGE DILUTED CONCENTRATION DURING PERIOD uCi/ML 9.06E-06 2.89E-06
3. PERCENT OF APPLICABLE LIMIT C. DISSOLVED AND ENTRAINED GASES
1. TOTAL RELEASE CURIES 4.83E-02 1.78E-03 1.00E+02
2. AVERAGE DILUTED CONCENTRATION DURING PERIOD uCi/ML 4.12E.08 1.65E-09
3. PERCENT OF APPLICABLE LIMIT D. GROSS ALPHA RADIOACTIVITY
1. TOTAL RELEASE CURIES 2.96E-05 6.67E-05 1.20E+02 E. WASTE VOL RELEASED (PRE-DILUTION)

LITERS 5.22E+06 3.81E+06 1.00E+01 F. VOLUME OF DILUTION WATER USED LITERS 1.17E+09 1.08E+09 1.60E+02 Applicable ILmits are expressed in terms of dose.

See Tables 1-3A and 1-3B of this report.

~ _

m i

(

TABLE 1-1A E.

I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 1996 Liquid Effluents - Summation of All Releases Unit: 1 Starting :

1-Jul-1996 Ending : 31-Dec-1996 TYPE OF EFFLUENT UNITS QUARTER 3 QUARTER 4 EST. TOT l ERROR %

j l

]

A.

FISSION & ACTIVATION PRODUCTS 1.

TOTAL RELEASE (NOT INCLUDING TRITIUM, GASES, ALPHA)

CURIES 1.32E-02 2.50E-02 4.70E+01

2. AVERAGE DILUTED CONCENTRATION DURING PERIOD uCi/ML 1.22E-08 2.83E-08 t

i

3. PERCENT OF APPLICABLE LIMIT B. TRITIUM
1. TOTAL RELEASE CURIES 2.77E+00 4.52E+00 3.70E+01

/'

2. AVERAGE DILUTED CONCENTRATION i

DURING PERIOD uCi/ML 2.56E-06 5.13E-06 x

................................................................................ 1 3.

PERCENT OF APPLICABLE LIMIT C. DISSOLVED AND ENTRAINED GASES 1.

TOTAL RELEASE CURIES 6.96E-03 5.71E-02 1.00E+02

2. AVERAGE DILUTED CONCENTRATION DURING PERIOD uCi/ML 6.44E-09 6.47E-08 3.

PERCENT OF APPLICABLE LIMIT D. GROSS ALPHA RADIOACTIVITY 1.

TOTAL RELEASE CURIES 1.56E-05 9.21E-07 1.20E+02 E. WASTE VOL RELEASED (PRE-DILUTION)

LITERS 3.98E+06 4.16E+06 1.00E+01 F. VOLUME OF DILUTION WATER USED LITERS 1.08E+09 8.82E+08 1.60E+02 Applicable ILmits are expressed in terms of dose.

See Tables

['

1-3A and 1-3B of this report.

(

i 1

l 1

C\\

\\

TABLE 1-1B J

E.

I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFUJENT RELEASE REPORT - 1996 Liquid Effluents - Summation of All Releases Unit: 2 Starting :

1.Jan-1996 Ending : 30-Jun-1996 1

TYPE OF EFFLUENT UNITS QUARTER 1 QUARTER 2 EST. TOT ERROR %

A.

FISSION & ACTIVATION PRODUCTS

1. TOTAL RELEASE (NOT INCLUDING TRITIUM, GASES, ALPHA)

CURIES 1.60E-02 3.17E-02 4.70E+01

2. AVERAGE DILUTED CONCENTRATION DURING PERIOD uCi/ML 1.81E-08 3.68E.08
3. PERCENT OF APPLICABLE LIMIT B. TRITIUM
1. TOTAL RELEASE CURIES 2.92E+00 3.17E+00 3.70E+01 p
2. AVERAGE DILUTED CONCENTRATION

(~)

DURING PERIOD uCi/ML 3.32E-06 3.68E-06

3. PERCENT OF APPLICABLE LIMIT C. DISSOLVED AND ENTRAINED GASES
1. TOTAL RELEASE CURIES 1.58E-02 4.34E-03 1.00E+02
2. AVERAGE DILUTED CONCENTRATION DURING PERIOD uCi/ML 1.79E-08 5.04E-09
3. PERCENT OF APPLICABLE LIMIT D. GROSS ALPHA RADIOACTIVITY 1.

TOTAL RELEASE CURIES 7.66E-07 1.31E-05 1.20E+02 E. WASTE VOL RELEASED (PRE-DILUTION)

LITERS 3.57E+06 3.44E+06 1.00E+01 F. VOLUME OF DILUTION WATER USED LITERS 8.82E+08 8.61E+08 1.60E+02 Applicable limits are expressed in terms of dose.

See Tables

[

1-3A and 1-3B of this report.

m()

TABLE 1-1B E.

I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT. 1996 Liquid Effluents. Summation of All Releases Unit: 2 Starting :

1-Jul.1996 Ending : 31-Dec-1996 TYPE OF EFFLUENT UNITS QUARTER 3 QUARTER 4 EST. TOT ERROR %

A.

FISSION & ACTIVATION PRODUCTS

1. TOTAL RELEASE (NOT INCLUDING TRITIUM, GASES, ALPHA)

CURIES 4.77E-03 3.32E-03 4.70E+01

2. AVERAGE DILUTED CONCENTRATION DURING PERIOD uCi/ML 4.95E-09 5.98E-09
3. PERCENT OF APPLICABLE LIMIT B. TRITIUM 1.

TOTAL RELEASE CURIES 2.71E+00 2.14E+00 3.70E+01

2. AVERAGE DILUTED CONCENTRATION s_s)

DURING PERIOD uCi/ML 2.81E-06 3.86E-06 3.

PERCENT OF APPLICABLE LIMIT C. DISSOLVED AND ENTRAINED GASES 1.

TOTAL RELEASE CURIES 5.76E-03 8.13E-04 1.00E+02

2. AVERAGE DILUTED CONCENTRATION DURING PERIOD uCi/ML 5.97E-09 1.47E-09 3.

PERCENT OF APPLICABLE LIMIT D. GROSS ALPHA RADIOACTIVITY 1.

TOTAL RELEASE CURIES 9.24E-06 1.40E-13 1.20E+02 E. WASTE VOL RELEASED (PRE-DILUTION)

LITERS 3.71E+06 2.24E+06 1.00E+01 F. VOLUME OF DILUTION WATER USED LITERS 9.65E+08 5.55E+08 1.60E+02 Applicable limits are expressed in terms of dose.

See Tables 7_s i

1-3A and 1-3B of this report.

t I

1 l

4 a

1 t

3 TABLE 1-1C 4 -

E.

I. HATCH NUCLEAR PLANT l

ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 1996 Liquid Effluents. Summation of All Release's Unit: Site l

Starting :

1-Jan-1996 Ending : 30.Jun-1996 1

i TYPE OF EFFLUENT UNITS QUARTER 1 QUARTER 2 EST. TOT :

ERROR %

1 4

i A. FISSION & ACTIVATION PRODUCTS e

a 4.

1. TOTAL RELEASE (NOT INCLUDING TRITIUM, GASES, ALPHA)

CURIES 6.14E-02 1.44E-01 4.70E+01

2. AVERAGE DILUTED CONCENTRATION i

DURING PERIOD uCi/ML 2.99E-08 7.42E-08 i.

3. PERCENT OF APPLICABLE LIMIT 1

B. TRITIUM 4

j

2. AVERAGE DILUTED CONCENTRATION 1

DURING PERIOD uCi/ML 6.60E-06 3.24E-06 1

3. PERCENT OF APPLICABLE LIMIT t

C. DISSOLVED AND ENTRAINED GASES 3

i

1. TOTAL RELEASE CURIES 6.41E-02 6.12E-03 1.00E+02

)

1

2. AVERAGE DILUTED CONCENTRATION j

DURING PERIOD uCi/ML 3.12E-08 3.15E-09 4

3. PERCENT OF APPLICABLE LIMIT l

D. GROSS ALPHA RADIOACTIVITY

1. TOTAL RELEASE CURIES 3.03E-05 7.98E-oS 1.20E+02

]

E. WASTE VOL RELEASED (PRE-DILUTION)

LITERS 8.79E+06 7.26E+06 1.00E+01 F. VOLUME OF DILUTION WATER USED LITERS 2.05E+09 1.94E+09 1.60E+02 j Applicable limits are expressed in terms of dose.

See Tables 1-3A and 1-3B of this report.

A i(,)1 TABLE 1-1C E.

I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT. 1996 Liquid Effluents - Summation of All Releases Unit: Site Starting :

1-Jul-1996 Ending : 31-Dec-1996 TYPE OF EFFLUENT UNITS QUARTER 3 QUARTER 4 EST. TOT ERROR %

A. FISSION & ACTIVATION PRODUCTS

1. TOTAL RELEASE (NOT INCLUDING TRITIUM, GASES, ALPHA)

CURIES 1.80E-02 2.83E-02 4.70E+01

2. AVERAGE DILUTED CONCENTRATION DURING PERIOD uCi/ML 8.78E-09 1.97E-08
3. PERCENT OF APPLICABLE LIMIT B. TRITIUM 1.

TOTAL RELEASE CURIES 5.48E+00 6.67E+00 3.70E+01 (A)

2. AVERAGE DILUTED CONCENTRATION k-)

DURING PERIOD uCi/ML 2.68E-06 4.64E-06

................................................................................ \\

3.

PERCENT OF APPLICABLE LIMIT C. DISSOLVED AND ENTRAINED GASES

1. TOTAL RELEASE CURIES 1.27E-02 5.79E-02 1.00E+02
2. AVERAGE DILUTED CONCENTRATION DURING PERIOD uCi/ML 6.22E.09 4.03E-08
3. PERCENT OF APPLICABLE LIMIT 4

D. GROSS ALPHA RADIOACTIVITY

................................................................................ I

1. TOTAL RELEASE CURIES 2.48E-05 9.21E-07 1.20E+02 '

................................................................................ 1 i

E. WASTE VOL RELEASED (PRE-DILUTION)

LITERS 7.70E+06 6.40E+06 1.00E+01 j F. VOLUME OF DILUTION WATER USED LITERS 2.05E+09 1.44E+09 1.60E+02 p

Applicable limits are expressed in tenns of dose.

See Tables l

1-3A and 1-3B of this report.

e)

~

~ ~

U i

t O

f TABLE 1-2A*

~~

j E.

I. HATCH NUCLEAR PLANT l

ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 1996 Liquid Effluents 1

Unit: 1 j

Starting :

1-Jan-1996 Ending : 30-Jun-1996 i

l CONTINUOUS MODE **

l BATCH MODE l

[

NUCLIDE l

UNIT l QUARTER 1 l QUARTER 2 l QUARTER 1 l QUARTER 2 l I

H-3 l

CURIES l 0.00E+00 l 0.00E+00 l 1.06E+01 l 3.12E+00 l 3

FISSION & ACTIVATION PRODUCTS AG-110M CURIES 0.00E+00 0.00E+00 0.00E+00 1.69E-04 AS-76 CURIES 0.00E+00 0.00E+00 1.56E-04 3.65F-06 I

BA-139 CURIES 0.00E+00 0.00E+00 1.44E-05 0.00E+00 BA-140 CURIES 0.00E+00 0.00E+00 1.17E-04 1.99E-05 i

("'

CE-141 CURIES 0.00E+00 0.00E+00 3.37E-04 4.87E-04 CE-144 CURIES 0.00E+00 0.00E+00 4.46E-04 1.10E-03 CO-58 CURIES 0.00E+00 0.00E+00 9.52E-04 2.85E-03 CO-60 CURIES 0.0GE+00 0.00E+00 9.07E-03 1.47E-02 CR-51 CURIES 0.00E+00 0.00E+00 1.37E-02 5.34E-02 CS-134 CURIES 0.00E+00 0.00E+00 1.68E-04 1.60E-04 CS-137 CURIES 0.00E+00 0.00E+00 1.37E-03 1.11E-03 CS-138 CURIES 0.00E+00 0.00E+00 4.75E-04 1.96E-05 i

FE-55 CURIES 0.00E+00 0.00E+00 3.73E-03 8.84E-03 FE-59 CURIES 0.00E+00 0.00E+00 3.50E-04 1.81E-03 HF-181 CGRIES 0.00E+00 0.00E+00 0.00E+00 6.03E-06 1-131 CURIES 0.00E+00 0.00E+00 9.13E-04 1.16E-04 I-132 CURIES 0.00E+00 0.00E+00 2.09E-06 0.00E+00 I-133 CURIES 0.00E+00 0.00E+00 1.59E-03 8.47E-05 I-135 CURIES 0.00E+00 0.00E+00 7.65E-05 0.00E+00 LA-140 CURIES 0.00E+00 0.00E+00 6.94E-04 1.15E-04 MN-54 CURIES 0.00E+00 0.00E+00 1.68E-03 3.95E-03 NB-95 CURIES 0.00E+00 0.00E+00 2.63E-04 1.18E-03 NB-97 CURIES 0.00E+00 0.00E+00 1.14E-04 1.83E-04 NP-239 CURIES 0.00E+00 0.00E+00 4.28E-05 0.00E+00 RB-88 CURIES 0.00E+00 0.00E+00 1.15E-04 0.00E+00 RB-89 CURIES 0.00E+00 0.00E+00 8.15E-05 0.00E+00 RU-103 CURIES 0.00E+00 0.00E+00 1.39E-04 1.23E-03 RU-106 CURIES 0.00E+00 0.00E+00 0.00E+00 3.08E-04 SB-122 CURIES 0.00E+00 0.00E+00 9.75E-07 7.68E-07 SB-124 CURIES 0.00E+00 0.00E+00 0.00E+00 1.56E-04 SR-89 CURIES 0.00E+00 0.00E+00 1.54E-04 1.56E-04 SR-90 CURIES 0.00E+00 0.00E+00 2.53E-07 2.02E-06 SR-91 CURIES 0.00E+00 0.00E+00 2.20E-05 0.00E+00. - - - --

(~N t

_s TABLE 1-2A*

E. I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT. 1996 Liquid Effluents Unit: 1 Starting :

1-Jan-1996 Ending : 30-Jun-1996 l CONTINUOUS MODE **

l BATCH MODE l

NUCLIDE l

UNIT l QUARTER 1 l QUARTER 2 l QUARTER 1 l QUARTER 2 l FISSION & ACTIVATION PRODUCTS SR-92 CURIES 0.00E+00 0.00E+00 6.34E-06 7.03E-06 TC-99M CURIES 0.00E+00 0.00E+00 3.53E-05 4.74E-06 Y-91M CURIES 0.00E+00 0.00E+00 8.69E-05 0.00E+00 Y-92 CURIES 0.00E+00 0.00E+00 1.72E-05 0.00E+00 ZN-65 CURIES 0.00E+00 0.00E+00 8.39E-03 1.94E-02

)

ZR-95 CURIES 0.00E+00 0.00E+00 1.37E-04 7.56E-04 l

TOTALS l

CURIES l 0.00E+00 l 0.00E+00 l 4.54E-02 l 1.12E-01 l l ts

(\\~j) i DISSOLVED AND ENTRAINED GASES j

AR-41 CURIES 0.00E+00 0.00E+00 1.35E-05 6.41E-06 KR-85 CURIES 0.00E+00 0.00E+00 0.00E+00 5.32E-04 i

KR-85M CURIES 0.00E+00 0.00E+00 1.51E-05 0.00E+00 XE-131M CURIES 0.00E+00 0.00E+00 0.00E+00 3.61E-05 XE-133 CURIES 0.00E+00 0.00E+00 9.34E-03 5.16E-04 XE-133M CURIES 0.00E+00 0.00E+00 1.70E-05 0.00E+00 XE-135 CURIES 0.00E+00 0.00E+00 3.81E-02 6.92E-04 XE-135M CURIES 0.00E+00 0.00E+00 8.62E-04 0.00E+00 TOTALS l

CURIES l 0.00E+00 l 0.00E+00 l 4.83E-02 l 1.78E-03 ll 1

G-ALPRA l

CURIES l 0.00E+00 l 0.00E+00 l 2.96E-05 l 6.67E-05 l Zeroes in this table indicate that no radioactivity was present at detectable levels.

See Table 1-5 for typical minimum detectable concentrations.

There are no continuous mode' radioactive liquid release pathways at Plant Hatch.

OV i

i d

\\j

~~

TABLE 1-2A*

E. I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 1996 Liquid Effluents

)

Unit: 1 Etarting :

1-Jul-1996 Ending : 31-Dec-1996 l CONTINUOUS MODE **

l BATCH MODE l

j NUCLIDE l

UNIT l QUARTER 3 l QUARTER 4 l QUARTER 3 l QUARTER 4 l H-3 l

CURIES l 0.00E+00 l 0.00E+00 l 2.77E+00 l 4.52E+00 l FISSION & ACTIVATION PRODUCTS AS-76 CURIES 0.00E+00 0.00E+00 2.50E-05 1.39E-03 BA-139 CURIES 0.00E+00 0.00E+00 0.00E+00 7.14E-05 BA-140 CURIES 0.00E+00 0.00E+00 0.00E+00 6.78E-04 CE-141 CURIES 0.00E+00 0.00E+00 1.24E-05 1.42E-04

("x CE-144 CURIES 0.00E+00 0.00E+00 0.00E+00 3.37E-05

,)

CO-58 CURIES 0.00E+00 0.00E+00 1.44E-05 8.52E-05

(

CO-60 CURIES 0.00E+00 0.00E+00 3.33E-03 5.07E-03 CR-51 CURIES 0.00E+00 0.00E+00 0.00E+00 7.92E-04 CS-134 CURIES 0.00E+00 0.00E+00 6.68E-04 5.18E-04 CS-137 CURIES 0.00E+00 0.00E+00 3.27E-03 2.93E-03 CS-138 CURIES 0.00E+00 0.00E+00 0.00E+00 3.86E-05 FE-55 CURIES 0.00E+00 0.00E+00 1.83E-03 2.07E-03 FE-59 CURIES 0.00E+00 0.00E+00 0.00E+00 6.22E-05 HF-181 CURIES 0.00E+00 0.00E+00 0.00E+00 7.30E-05 I-131 CURIES 0.00E+00 0.00E.00 2.58E-04 7.70E-04 I-132 CURIES 0.00E+00 0.00E+00 0.00E+00 2.00E-05 I-133 CURIES 0.00E+00 0.00E+00 6.25E-04 2.56E-03 I-135 CURIES 0.00E+00 0.00E+00 0.00E+00 4.79E-04 LA-140 CURIES 0.00E+00 0.00E+00 1.96E-05 5.94E-04 MN-54 CURIES 0.00E+00 0.00E+00 4.70E-04 7.28E-04 MN-56 CURIES 0.00E+00 0.00E+00 0.00E+00 2.50E-05 MO-99 CURIES 0.00E+00 0.00E+00 0.00E+00 1.16E-04 NA-24 CURIES 0.00E+00 0.00E+00 3.44E-06 1.46E-04 NB-95 CURIES 0.00E+00 0.00E+00 9.15E-07 2.70E-06 NB-97 CURIES 0.00E+00 0.00E+00 0.00E+00 3.57E-04 RU-103 CURIES 0.00E+00 0.00E+00 2.13E-06 0.00E+00 SB-122 CURIES 0.00E+00 0.00E+00 5.28E-06 1.99E-06 SR-89 CURIES 0.00E+00 0.00E+00 1.96E-04 1.28E-04 SR-90 CURIES 0.00E+00 0.00E+00 7.18E-13 5.29E-13 SR-91 CURIES 0.00E+00 0.00E+00 0.00E+00 1.16E-04 SR-92 CURIES 0.00E+00 0.00E+00 0.00E+00 1.42E-04 TC-99M CURIES 0.00E+00 0.00E+00 1.75E-06 4.79E-04

(

Y-91M CURIES 0.00E+00 0.00E+00 1.51E-05 3.05E-04 l

f 1

L 4

i V

TABLE 1-2A*

E.

I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 1996 Liquid Effluents Unit: 1 Starting :

1-Jul-1996 Ending : 31-Dec-1996 l CONTINUOUS MODE **

l BATCH MODE l

1 NUCLIDE l

UNIT l QUARTER 3 l QUARTER 4 l QUARTER 3 l QUARTER 4 l l

i FISSION & ACTIVATION PRODUCTS ZN-65 CURIES 0.00E+00 0.00E+00 1.84E-03 2.69E-03 ZN-69M CURIES 0.00E+00 0.00E+00 0.00E+00 9.38E-05 TOTALS l

CURIES l 0.00E+00 l 0.00E+00 l 1.32E-02 l 2.50E-02 l DISSOLVED AND ENTRAINED GASES

(s i

KR-85 CURIES 0.00E+00 0.00E+00 1.18E-03 1.32E-04 KR-05M CURIES 0.00E+00 0.00E+00 0.00E+00 4.59E-06 XE-133 CURIES 0.00E+00 0.00E+00 1.20E-03 1.18E-02 XE-133M CURIES 0.00E+00 0.00E+00 0.00E+00 9.87E-05 XE-135 CURIES 0.00E+00 0.00E+00 4.39E-03 4.32E-02 XE-135M CURIES 0.00E+00 0.00E+00 1.89E-04 1.80E-03 TOTALS l

CURIES l 0.00E+00 l 0.00E+00 l 6.96E-03 l 5.71E-02 l G-ALPHA l

CURIES l 0.00E+00 l 0.00E+00 l 1.56E-05 l 9.21E-07 l Zeroes in this table indicate that no radioactivity was present at detectable levels.

See Table 1-5 for typical minimum detectable concentrations.

There are no continuous mode radioactive liquid release pathways at Plant Hatch.

i 4

pb

~~

TABLE 1-2B*

E.

I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 1996 Liquid Effluents Unit: 2 Starting :

1-Jan-1996 Ending : 30-Jun-1996 l CONTINUOUS MODE **

l BATCH MODE l

NUCLIDE l

UNIT l QUARTER 1 l QUARTER 2 l QUARTER 1 l QUARTER 2 l i

H-3 l

CURIES l 0.00E+00 l 0.00E+00 l 2.92E+00 l 3.17E+00 l FISSION & ACTIVATION PRODUCTS AG-110M CURIES 0.00E+00 0.00E+00 1.40E-05 9.52E.06 AS-76 CURIES 0.00E+00 0.00E+00 2.71E-03 1.05E-04 BA-140 CURIES 0.00E+00 0.00E+00 9.86E-05 0.00E+00 CE-141 CURIES 0.00E+00 0.00E+00 1.98E-06 3.89E-05

/

CE-144 CURIES 0.00E+00 0.00E+00 0.00E+00 7.10E-05

(_,h/

CO-58 CURIES 0.00E+00 0.00E+00 3.36E-04 1.36E-03 CO-60 CURIES 0.00E+00 0.00E+00 2.41E-03 8.29E-03 CR-51 CURIES 0.00E+00 0.00E+00 1.25E-03 6.29E-03 CS-134 CURIES 0.00E+00 0.00E+00 1.06E-05 5.68E-04 CS-137 CURIES 0.00E+00 0.00E+00 5.41E-04 1.09E-03 CS-138 CURIES 0.00E+00 0.00E+00 2.11E-04 2.77E-05 FE-55 CURIES 0.00E+00 0.00E+00 2.50E-04 8.99E-04 i

FE-59 CURIES 0.00E+00 0.00E+00 0.00E+00 6.23E-05 I-131 CURIES 0.00E+00 0.00E+00 1.77E-04 7.61E-05 I-132 CURIES 0.00E+00 0.00E+00 3.64E-05 0.00E+00 I-133 CURIES 0.00E+00 0.00E+00 3.84E-04 2.22E-04 I-135 CURIES 0.00E+00 0.00E+00 7.87E-05 2.49E-05 LA-140 CURIES 0.00E+00 0.00E+00 8.04E-05 7.20E-06 MN-54 CURIES 0.00E+00 0.00E+00 6.77E-04 2.37E-03 MN-56 CURIES 0.00E+00 0.00E+00 3.43E-05 0.00E+00 MO-99 CURIES 0.00E+00 0.00E+00 1.69E-04 0.00E+00 NA-24 CURIES 0.00E+00 0.00E+00 2.06E-03 6.34E.05 NB-95 CURIES 0.00E+00 0.00E+00 0.00E+00 2.70E-04 NB-97 CURIES 0.00E+00 0.00E+00 2.40E-04 2.01E-05 NP-239 CURIES 0.00E+00 0.00E+00 1.67E-04 0.00E+00 RU-103 CURIES 0.00E+00 0.00E+00 0.00E+00 1.55E-04 RU-105 CURIES 0.00E+00 0.00E+00 9.74E-05 0.00E+00 RU-106 CURIES 0.00E+00 0.00E+00 0.00E+00 6.39E-05 SB-122 CURIES 0.00E+00 0.00E+00 3.37E-05 0.00E+00 SB-124 CURIES 0.00E+00 0.00E+00 0.00E+00 3.19E-05 SR-89 CURIES 0.00E+00 0.00E+00 5.25E-05 1.12E-04 SR-90 CURIES 0.00E+00 0.00E+00 2.22E-12 9.55E-06

(

SR-91 CURIES 0.00E+00 0.00E+00 1.26E-04 0.00E+00

._ _ =. _ ___.___

h i

i i

!i

-g 0

~~

TABLE 1-2B*

l E. I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 1996 Liquid Effluents i

Unit: 2 Starting :

1-Jan-1996 Ending : 30-Jun-1996 4

i l CONTINUOUS MODE **

l BATCH MODE l

NUCLIDE l

UNIT l QUARTER 1 l QUARTER 2 l QUARTER 1 l QUARTER 2 l FISSION & ACTIVATION PRODUCTS

................................................................................ i SR-92 CURIES 0.00E+00 0.00:e00 2.65E-05 2.96E-06 TC-99M CURIEL 0.00E+00 0.00E+00 5.20E-04 4.63E-05 Y-91M CURIES 0.00E+00 0.00E+00 2.64E-04 2.06E-05 Y-92 CURIES 0.00E+00 0.00E+00 3.43E-04 1.87E-04 ZN-65 CURIES 0.00E+00 0.00E+00 2.51E-03 9.10E-03 ZN-69M CURIES 0.00E+00 0.00E+00 6.78E-05 1.40E-06 ZR-95 CURIES 0.00E+00 0.00E+00 0.00E+00 1.13E-04

/"')

TOTALS l

CURIES l 0.00E+00 l 0.00E+00 l 1.60E-02,l 3.17E-02 l

( j DISSOLVED AND ENTRAINED GASES XE-133 CURIES 0.00E+00 0.00E+00 2.50E-03 1.06E-03 XE-133M CURIES 0.00E+00 0.00E+00 1.55E-05 1.05E-05 XE-135 CURIES 0.00E+00 0.00E+00 1.31E-02 2.53E-03 XE-135M CURIES 0.00E+00 0.00E+00 1.92E-04 7.39E-04 TOTALS l

CURIES l 0.00E+00 l 0.00E+00 l 1.58E-02 l 4.34E-03 l ;

G-ALPHA l

CURIES l 0.00E+00 l 0.00E+00 l 7.66E-07 l 1.31E-05 l Zeroes in this table indicate that no radioactivity was present at detectable levels.

See Table 1-5 for typical minimum detectable concentrations.

There are no continuous mode radioactive liquid release pathways at Plant Hatch. __

~~

TABLE 1-2B*

E. I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 1996 Liquid Effluents Unit: 2 Starting :

1-Jul-1996 Ending : 31-Dec-1996 l CONTINUOUS MODE **

l BATCH MODE l

NUCLIDE l

UNIT l QUARTER 3 l QUARTER 4 l QUARTER 3 l QUARTER 4 l l

H-3 l

CURIES l 0.00E+00 l 0.00E+00 l 2.71E+00 l 2.14E+00 l FISSION & ACTIVATION PRODUCTS BA-133 CURIES 0.00E+00 0.00E+00 2.08E-06 0.00E+00 BA-140 CURIES 0.00E+00 0.00E+00 0.00C+00 5.32E-06 CE-141 CURIES 0.00E+00 0 00E+00 1.28E-05 0.00E+00

(}

CO-58 CURIES 0.00E+00 0.00E+00 3.56E-05 3.59E-05

(,f CO-60 CURIES 0.00E+00 0.00E+00 8.89E-04 1.18E-03 CR-51 CURIES 0.00E+00 0.00E+00 4.85E-04 3.41E-05 CS-134 CURIES 0.00E+00 0.00E+00 4.79E-05 4.35E-05 CS-137 CURIES 0.00E+00 0.00E+00 3.95E-04 5.96E-04 CS-138 CURIES 0.00E+00 0.00E+00 5.82E-05 1.58E-04 FE-55 CURIES 0.00E+00 0.00E+00 3.13E-04 1.98E-04 FE-59 CURIES 0.00E+00 0.00E+00 8.11E-06 0.00E+00 I-131 CURIES 0.00E+00 0.00E+00 4.93E-05 7.38E-06 I-132 CURIES 0.00E+00 0.00E+00 7.16E-05 0.00E+00 I-133 CURIES 0.00E+00 0.00E+00 4.37E-04 2.01E-05 I-135 CURIES 0.00E+00 0.00E+00 4.34E-04 0.00E+00 LA-140 CURIES 0.00E+00 0.00E+00 1.22E-05 0.00E+00 MN-54 CURIES 0.00E+00 0.00E+00 2.40E-04 7.14E-04 MN-56 CURIES 0.00E+00 0.00E+00 7.50E-06 0.00E+00 MO-99 CURIES 0.00E+00 0.00E+00 6.57E-06 0.00E+00 NA-24 CURIES 0.00E+00 0.00E+00 9.01E-05 3.72E-06 NB-95 CURIES 0.00E+00 0.00E+00 2.05E-06 5.75E-07 NB-97 CURIES 0.00E+00 0.00E+00 2.03E-05 0.00E+00 RU-103 CURIES 0.00E+00 0.00E+00 8.31E-06 0.00E+00 SB-122 CURIES 0.00E+00 0.00E+00 8.13E-07 0.00E+00 SR-89 CURIES 0.00E+00 0.00E+00 3.79E-05 9.09E-13 SR-90 CURIES 0.00E+00 0.00E+00 0.00E+00 1.21E-13 SR-91 CURIES 0.00E+00 0.00E+00 3.10E-05 0.00E+00 SR-92 CURIES 0.00E+00 0.00E+00 1.90E-06 0.00E+00 TC-99M CURIES 0.00E+00 0.00E+00 5.32E-05 0.00E+00 Y-91M CURIES 0.00E+00 0.00E+00 2.89E-05 0.00E+00 Y-92 CURIES 0.00E+00 0.00E+00 1.10E-04 0.00E+00

[d~'T ZN-65 CURIES 0.00E+00 0.00E+00 4.54E-04 3.20E-04 a

  • i\\s,/

~~

TABLE 1-2B*

E.

I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 1996 Liquid Effluents Unit: 2 Starting :

1-Jul-1996 Ending : 31-Dec-1996 l CONTINUOUS MODE **

l BATCH MODE l

NUCLIDE l

UNIT l QUARTER 3 l QUARTER 4 l QUARTER 3 l QUARTER 4 l FISSION & ACTIVATION PRODUCTS ZN-69M l

CURIES l 0.00E+00 l 0.00E+00 l 7.56E-07 l 0.00E+00 l TOTALS l

CURIES l 0.00E+00 l 0.00E+00 l 4.77E-03 l 3.32E-03 l DISSOLVED AND ENTRAINED GASES XE-133 CURIES 0.00E+00 0.00E+00 9.69E-04 3.02E-04

("'N XE-133M CURIES 0.00E+00 0.00E+00 1.53E-05 0.00E+00

'x_,)

XE-135 CURIES 0.00E+00 0.00E+00 3.64E-03 4.63E-04 XE-135M CURIES 0.00E+00 0.00E+00 1.14E-03 4.85E-05 TOTALS l

CURIES l 0.00E+00 l C.00E+00 l 5.76E-03 l 8.13E-04 l G-ALPHA l

CURIES l 0.00E+00 l 0.00E+00 l 9.24E-06 l 1.40E-13 l 1

Zeroes in this table indicate that no radioactivity was present at detectable levels.

See Table 1-5 for typical minimum detectable concentrations.

There are no continuous mode radioactive liquid release pathways at Plant Hatch.

O\\J t

O()

~~

TABLE 1-2C*

E. I. FATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 1996 I

Liquid Effluents Unit: Site Starting :

1-Jan-1996 Ending : 30-Jun-1996 l CONTINUOUS MODE **

l BATCH MODE l

NUCLIDE l

UNIT l QUARTER 1 l QUARTER 2 l QUARTER 1 l QUARTER 2 l i

1 H-3 l

CURIES l 0.00E+00 l 0.00E+00 l 1.35E+01 l 6.29E+00 l 1

FISSION & ACTIVATION PRODUCTS AG-110M CURIES 0.00E+00 0.00E+00 1.40E-05 1.79E-04 AS-76 CURIES 0.00E+00 0.00E+00 2.86E-03 1.08E-04 BA-139 CURIES 0.00E+00 0.00E+00 1.44E-05 0.00E+00 BA-140 CURIES 0.00E+00 0.00E+00 2.16E-04 1.99E-05 1

{}e CE-141 CURIES 0.00E+00 0.00E+00 3.39E-04 5.26E-04 CE-144 CURIES 0.00E+00 0.00E+00 4.46E-04 1.17E-03 s_,

CO-58 CURIES 0.00E+00 0.00E+00 1.29E-03 4.21E-03 CO-60 CURIES 0.00E+00 0.00E+00 1.15E-02 2.30E-02 CR-51 CURIES 0.00E+00 0.00E+00 1.49E-02 5.97E-02 CS-134 CURIES 0.00E+00 0.00E+00 1.79E-04 7.28E-04 CS-137 CURIES 0.00E+00 0.00E+00 1.92E-03 2.20E-03 CS-138 CURiks 0.00E+00 0.00E+00 6.86E-04 4.73E-05 FE-55 CURIES 0.00E+00 0.00E+00 3.98E-03 9.73E-03 FE-59 CURIES 0.00E+00 0.00E+00 3.50E-04 1.87E-03 l

HF-181 CURIES 0.00E+00 0.00E+00 0.00E+00 6.03E-06

)

I-131 CURIES 0.00E+00 0.00E+00 1.09E-03 1.92E-04 I-132 CURIES 0.00E+00 0.00E+00 3.85E-05 0.00E+00 I-133 CURIES 0.00E+00 0.00E+00 1.97E-03 3.07E-04 I-135 CURIES 0.00E+00 0.00E+00 1.55E-04 2.49E-05 LA-140 CURIES 0.00E+00 0.00E+00 7.74E-04 1.22E-04 MN-54 CURIES 0.00E+00 0.00E+00 2.36E-03 6.33E-03 MN-56 CURIES 0.00E+00 0.00E+00 3.43E-05 0.00E+00 MO-99 CURIES 0.00E+00 0.00E+00 1.69E-04 0.00E+00 NA-24 CURIES 0.00E+00 0.00E+00 2.06E-03 6.34E-05 NB-95 CURIES 0.00E+00 0.00E+00 2.63E-04 1.45E-03 NB-97 CURIES 0.00E+00 0.00E+00 3.54E-04 2.03E-04 NP-239 CURIES 0.00E+00 0.00E+00 2.09E-04 0.00E+00 RB-88 CURIES 0.00E+00 0.00E+00 1.15E-04 0.00E+00 i

RB-89 CURIES 0.00E+00 0.00E+00 8.15E-05 0.00E+00 RU-103 CURIES 0.00E+00 0.00E+00 1.39E-04 1.38E-03 j

RU-105 CURIES 0.00E+00 0.00E+00 9.74E-05 0.00E+00 RU-106 CURIES 0.00E+00 0.00E+00 0.00E+00 3.72E-04

[)

SB-122 CURIES 0.00E+00 0.00E+00 3.47E-05 7.68E-07 j

s-

, l

O

~~

TABLE 1-2C*

E. I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 1996 Liquid Effluents Unit: Site Stai-ting :

1-Jan-1996 Ending : 30-Jun-1996 l CONTINUOUS MODE **

l BATCH MODE l

L

.NUCLIDE l

UNIT l QUARTER 1 l QUARTER 2 l QUARTER 1 l QUARTER 2 l l

FISSION & ACTIVATION PRODUCTS SB-124 OURIES 0.00E+00 0.00E+00 0.00E+00 1.88E-04 SR-89 CURIES 0.00E+00 0.00E+00 2.06E-04 2.68E-04 SR-90 CURIES 0.00E+00 0.00E+00 2.53E-07 1.16E-05 SR-91 CURIES 0.00E+00 0.00E+00 1.48E-04 0.00E+00 SR-92 CURIES 0.00E+00 0.00E+00 3.28E-05 1.00E-05 TC-99M CURIES 0.00E+00 0.00E+00 5.55E-04 5.10E-05 Y-91M CURIES 0.00E+00 0.00E+00 3.50E-04 2.06E-05 Y-92 CURIES 0.00E+00 0.00E+00 3.60E-04 1.87E-04 ZN-65 CURIES 0.00E+00 0.00E+00 1.09E-02 2.85E-02 ZN-69M CURIES 0.00E+00 0.00E+00 6.78E-05 1.40E-06 ZR-95 CURIES 0.00E+00 0.00E+00 1.37E-04 8.68E-04 TOTALS l

CURIES l 0.00E+00 l 0.00E+00 l 6.14E-02 l 1.44E-01 l j

DISSOLVED AND ENTRAINED GASES AR-41 CURIES 0.00E+00 0.00E+00 1.35E-05 6.41E-06 i

KR-85 CURIES 0.00E+00 0.00E+00 0.00E+00 5.32E-04 KR-85M CURIES 0.00E+00 0.00E+00 1.51E-05 0.00E+00 XE-131M CURIES 0.00E+00 0.00E+00 0.00E+00 3.61E-05 XE-133 CURIES 0.00E+00 0.00E+00 1.18E-02 1.58E-03 XE-133M CURIES 0.00E+00 0.00E+00 3.25E-05 1.05E-05 XE-135 CURIES 0.00E+00 0.00E+00 5.11E-02 3.22E-03 XE-135M CURIES 0.00E+00 0.00E+00 1.05E-03 7.39E-04 TOTALS l

CURIES l 0.00E+00 l 0.00E+00 l 6.41E-02 l 6.12E-03 l G-ALPHA l

CURIES l 0.00E+00 l 0.00E+00 l 3.03E-05 l 7.98E-05 l Zeroes in this table indicate that no radioactivity was present at detectable levels.

See Table 1-5 for typical minimum i

detectable concentrations.

There are no continuous mode radioactive liquid, release pathways at Plant Hatch.

r

-~

TABLE 1-2C*

E. I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT. 1996 Liquid Effluents Unit: Site Starting :

1-Jul-1996 Ending : 31-Dec-1996 l CONTINUOUS MODE **

l BATCH MODE l

l NUCLIDE l

UNIT l QUARTER 3 l QUARTER 4 l QUARTER 3 l QUARTER 4 l H-3 l

CURIES l 0.00E+00 l 0.00E+00 l 5.48E+00 l 6.67E+00 l FISSION & ACTIVATION PRODUCTS AS-76 CURIES 0.00E+00 0.00E+00 4.55E-04 1.40E-03 BA-133 CURIES 0.00E+00 0.00E+00 2.08E-06 0.00E+00 BA-139 CURIES 0.00E+00 0.00E+00 0.00E+00 7.14E-05 BA-140 CURIES 0.00E+00 0.00E+00 0.00E+00 6.84E-04

/}

CE-141 CURIES 0.00E+00 0.00E+00 2.52E-05 1.42E 04

(,/

CE-144 CURIES 0.00E+00 0.00E+00 0.00E+00 3.37E-05 1

CO-58 CURIES 0.00E+00 0.00E+00 5.00E-05 1.21E-04

]

CO-60 CURIES 0.00E+00 0.00E+00 4.22E-03 6.25E-03 CR-51 CURIES 0.00E+00 0.00E+00 4.85E-04 8.27E-04 CS-134 CURIES 0.00E+00 0.00E+00 7.16E-04 5.61E-04 CS-137 CURIES 0.00E+00 0.00E+00 3.66E-03 3.52E-03 CS-138 CURIES 0.00E+00 0.00E+00 5.82E-05 1.96E-04 FE-55 CURIES 0.00E+00 0.00E+00 2.15E-03 2.27E-03 FE-59 CURIES 0.00E+00 0.00E+00 8.11E-06 6.22E-05 HF-181 CURIES 0.00E+00 0.00E+00 0.00E+00 7.30E-05 I-131 CURIES 0.00E+00 0.00E+00 3.07E-04 7.78E-04 I-132 CURIES 0.00E+00 0.00E+00 7.16E-05 2.00E-05 I-133 CURIES 0.00E+00 0.00E+00 1.06E-03 2.58E-03 I-135 CURIES 0.00E+00 0.00E+00 4.34E-04 4.79E-04 LA-140 CURIES 0.00E+00 0.00E+00 3.18E-05 5.94E-04 MN-54 CURIES 0.00E+00 0.00E+00 7.11E-04 1.44E-03 MN-56 CURIES 0.00E+00 0.00E+00 7.50E-06 2.50E-05 MO-99 CURIES 0.00E+00 0.00E+00 6.57E-06 1.16E-04 NA-24 CURIES 0.00E+00 0.00E+00 9.36E-05 1.50E-04 NB-95 CURIES 0.00E+00 0.00E+00 2.97E-06 3.28E-06 NB-97 CURIES 0.00E+00 0.00E+00 2.03E-05 3.57E-04 RU-103 CURIES 0.00E+00 0.00E+00 1.04E-05 0.00E+00 SB-122 CURIES 0.00E+00 0.00E+00 6.10E-06 1.99E-06 SR-89 CURIES 0.00E+00 0.00E+00 2.34E-04 1.28E-04 SR-90 CURIES 0.00E+00 0.00E+00 7.18E-13 6.50E-13 SR-91 CURIES 0.00E+00 0.00E+00 3.10E-05 1.16E-04 SR-92 CURIES 0.00E+00 0.00E+00 1.90E-06 1.42E-04

/

TC-99M CURIES 0.00E+00 0.00E+00 5.50E-05 4.79E-04 C

G I

~~

TABLE 1-2C*

E. I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT. 1996 4

Liquid Effluents I

Unit: Site Starting :

1-Jul-1996 Ending : 31-Dec-1996 J

i j

l CONTINUOUS MODE **

l BATCH MODE l

i 1

NUCLIDE l

UNIT l QUARTER 3 l QUARTER 4 l QUARTER 3 l QUARTER 4 l j

I FISSION & ACTIVATION PRODUCTS i

Y-91M CURIES 0.00E+00 0.00E+00 4.40E-05 3.05E-04 i

Y-92 CURIES 0.00E+00 0.00E+00 7.10E-04 1.27E-03 ZN-65 CURIES 0.00E+00 0.00E+00 2.30E-03 3.01E-03 ZN-69M CURIES 0.00E+00 0.00E+00 7.56E-07 9.38E-05 TOTALS l

CURIES l 0.00E+00 l 0.00E+00 l 1.80E-02 l 2.83E-02 l

-i DISSOLVED AND ENTRAINED GASES

(

KR-85 CURIES 0.00E+00 0.00E+00 1.18E 1.32E-04 KR-85M CURIES 0.00E+00 0.00E+00 0.00E+00 4.59E-06 XE-133 CURIES 0.00E+00 0.00E+00 2.17E-03 1.21E-02 XE-133M CURIES 0.00E+00 0.00E+00 1.53E-05 9.87E-05 XE-135 CURIES 0.00E+00 0.00E+00 8.03E-03 4.37E-02 XE-135M CURIES 0.00E+00 0.00E+00 1.33E-03 1.85E-03 TOTALS l

CURIES. l 0.00E+00 l 0.00E+00 l 1.27E-02 l 5.79E-02 l l G-ALPHA l

CURIES l 0.00E+00 l 0.00E+00 l 2.48E-05 l 9.21E-07 l Zeroes in this table indicate that no radioactivity was present at detectable levels.

See Table 1-5 for typical minimum detectable concentrations.

There are no continuous mode radioactive liquid release pathways at Plant Hatch.

("'

\\_

1 )

1 r

TABLE 1-3A E. I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 1996 DOSES TG A MEMBER OF THE PUBLIC DUE TO LIQUID RELEASES Unit: 1

)

Starting: 01-Jan-1996 Ending: 30-Jun-1996 Cumulative Doses per Quarter Organ Tech Units Quarter t of Quarter

% of Spec 1

Tech 2

Tech j

Limit Spec Spec Limit Limit Bone s

mrem 6.46E-03 1.29E-01 5.66E-03 1.13E-01 Liver

.0 mrem 1.14E-02 2.28E-01 1.18E-02 2.35E-01 TBody 1.5 mrem 7.46E-03 4.97E-01 7.31E-03 4.87E-01 Thyroid 5.0 mrem 6.26E-03 1.25E-01 5.99E-04 1.20E-02 Kidney 5.0 mrem 4.83E-03 9.65E-02 5.68E-03 1.14E-01 Lung 5.0 mrem 9.68E-04 1.94E-02 6.66E-04 1.33E-02 GILLI 5.0 mrem 8.30E-03 1.66E-01 1.34E-02 2.68E-01 Cumulative Doses per Year

\\

Organ Tech Units Year to

% of Spec Ending Tech Limit Date Spec Limit Bone 10.0 mrem 1.21E-02 1.21E-01 Liver 13.0 mrem 2.32E-02 2.32E-01 l

TBody 3.0 mrem 1.48E-02 4.92E-01

{

Thyroid 10.0 mrem 6.86E-03 6.86E-02 j

Kidney 10.0 mrem 1.05E-02 1.05E-01 Lung 10.0 mrem 1.63E-03 1.63E-02 GILLI 10.0 mrem 2.17E-02 2.17E-01

)

TABLE 1-3A E.

I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 1996 DOSES TO A MEMBER OF THE PUBLIC DUE TO LIQUID RELEASES Unit: 1 Starting: 01-Jul-1996 Ending: 31-Dec-1996 Cumulative Doses per Quarter Organ Tech Units Quarter i of Quarter t of Spec 3

Tech 4

Tech Limit Spec Spec Limit Limit Bone 5.0 mrem 1.10E-02 2.19E-01 1.24E-02 2.48E-01 Liver 5.0 mrem 1.69E-02 3.37E-01 1.92E-02 3.84E-01 TBody 1.5 mrem 1.16E-02 7.76E-01 1.32E-02 8.77E-01 Thyroid 5.0 mrem 1.51E-03 3.01E-02 6.15E-03 1.23E-01 Kidney 5.0 mrem 5.83E-03 1.17E-01 6.79E-03 1.36E-01 Lung 5.0 mrem 1.83E-03 3.66E-02 2.04E-03 4.09E-02 GILLI 5.0 mrem 2.08E-03 4.16E-02 4.07E-03 8.13E-02 Cumulative Doses per Year N

Organ Tech Units Year to

%.of Spec Ending Tech Limit Date Spec Limit

}

Bone 10.0 mrem 3.55E-02 3.55E-01 Liv 6r 10.0 mrem 5.92E-02 5.92E-01 TBody 3.0 mrem 3.96E-02 1.32E+00 Thyroid 10.0 mrem 1.45E-02 1.45E-01 Kidney 10.0 mrem 2.31E-02 2.31E-01 Lung 10.0 mrem 5.51E-03 5.51E-02 GILLI 10.0 mrem 2.78E-02 2.78E-01

\\

d i

)

s TABLE 1-3B E. I. EATCH NUCLEAR PLANT j

ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 1996 DOSES TO A MEMBER OF THE PUBLIC DUE TO LIQUID RELEASES Unit: 2 Starting: 01-Jan-1996 Ending: 30-Jun-1996 Cumulative Doses per Quarter Organ Tech Units Quarter

% of Quarter

% of Spec 1

Tech 2

Tech Limit Spec Spec i

Limit Limit Bone 5.0 mram 2.38E-03 4.76E-02 6.55E-03 1.31E-01 Liver 5.0 mrem 3.91E-03 7.83E-02 1.27E-02 2.53E-01 TBody 1.5 mrem 2.50E-03 1.67E-01 8.63E-03 5.75E-01 Thyroid 5.0 mrem 1.27E-03 2.55E-02 6.07E-04 1.21E-02 Kidney 5.0 mrem 1.64E-03 3.28E-02 5.22E-03 1.04E-01 Lung 5.0 mrem 3.53E-04 7.06E-03 1.04E-03 2.07E-02 GILLI 5.0 mrem 2.16E-03 4.32E-02 7.36E-03 1.47E-01 i

. h)

Cumulative Doses per Year

\\,

Organ Tech Units Year to

% of Spec Ending Tech Limit Date Spec Limit Bone 10.0 mrem 8.93E-03 8.93E-02 Liver 10.0 mrem 1.66E-02 1.66E-01 TBody 3.0 mrem 1.11E-02 3.71E-01 Thyroid 10.0 mrem 1.88E-03 1.88E-02 Kidney 10.0 mrem 6.86E-03 6.86E-02 Lung 10.0 mrem 1.39E-03 1.39E-02 GILLI 10.0 mrem 9.52E-03 9.52E-02

. = -..

. ~. _.

A l

. C t'

TABLE 1-3B

^

E. I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE FFFLUENT RELEASE REFORT - 1996 DOSES TO A MEMBER OF THE PUBLIC DUE TO LIQUID RELEASES 4

Unit: 2 Starting: 01-Jul-2996 Ending: 31-Dec-1996 Cumulative Doses per Quarter 3

Organ Tech Units Quarter

% of Quarter

% of Spec 3

Tech 4

Tech Limit Spec Spec Limit Limit Bone 5.0 mrem 1.58E-03 3.16E-02 2.29E-03 4.59E-02 l

Liver 5.0 mrem 2.43E-03 4.86E-02 3.39E-03 6.79E-02

~

TBody

'1.5 mrem 1.65E-03 1.10E-01 2.30E-03 1.53E-01 Thyroid 5.0 mrem 5.52E-04 1.10E-02 7.87E-05 1.57E-03 Kidney 5.0 mrem 8.77E-04 1.75E-02 1.38E-03 2.37E-02 i

Lung 5.0 mrem 2.69E-04 5.38E-03 3.77E-04 7.55E-03 l

GILLI 5.0 mrem 6.49E 1.30E-02 8.61E-04 1.72E-02

.......__........................-04 j

4 Cumulative Doses per Year Organ Tech Units Year to

%.of Spec Ending Tech Limit Date Spec 4

j Limit Bone 10.0 mrem 1.28E-02 1.28E-01 Liver 10.0 mrem 2.24E-02 2.24E-01 TBody 3.0 mrem 1.51E-02 5.03E-01 Thyroid 10.0 mrem 2.51E-03 2.51E-02 Kidney 10.0 mrem 8.92E-03 8.92E-02 Lung 10.0 mrem 2.04E-03 2.04E-02 GILLI 10.0 mrem 1.10E-02 1.10E-01 i

i

O

l' l

r

' (

TABLE 1-4A E. I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT.

1 Liquid Effluents. Batch Release Summary

  • 996 Unit: 1 Starting :

1-Jan-1996 Ending : 30-Jun-1996

{

i i

i LIQUID RELEASES NUMBER OF BATCH RELEASES 281 i

TOTAL TIME PERIOD FOR BATCH RELEASES 37288.00 MINUTES MAXIMUM TIME PERIOD FOR A BATCH RELEASE 187.00 MINUTES AVERAGE TIME PERIOD FOR BATCH RELEASES 132.70 MINUTES MINIMUM TIME PERIOD FOR A BATCH RELEASE 78.00 MINUTES AVERAGE STREAM FLOW DURING PERIODS OF RELEASE OF LIQUID EFFLUENT INTO A FLOWING STREAM :

1.65E+04 CFS l

l l

l t

?

l i

1 i

a e

a T

i 4

4 4

TABLE 1-4A E. I. HATCH NUCLEAR PLANT

~

ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT.

1996 Liquid Effluents - Batch Release Summary '

Unit: 1 Starting :

1-Jul-Ho6 Ending : 31-Dec-1996 1

i LIQUID RELEASES

]

1 NUMBER OF BATCH RELEASES 242 TOTAL TIME PERIOD FOR BATCH RELEASES 33189.18 MINUTES MAXIMUM TIME PERIOD FOR A BATCH RELEASE 197.00 MINUTES AVERAGE TIME PERIOD FOR BATCH RELEASES 137.15 MINUTES MINIMUM TIME PERIOD FOR A BATCH RELEASE 88.00 MINUTES j-AVERAGE STREAM FLOW DURING PERIODS OF 1

1 RELEASE OF LIQUID EFFLUENT INTO A FLOWING STREAM :

1.65E+04 CFS j

i k

i J

l i

i O

TABLE 1-4B E. I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -

1996 Liquid Effluents - Batch Release Summary

  • Unit: 2 Starting :

1-Jan-1996 Ending : 30-Jun-1996 LIQUID RELEASES NUMBER OF BATCH RELEASES 249 TOTAL TIME PERIOD FOR BATCH RELEASES 35273.00 MINUTES MAXIMUM TIME PERIOD FOR A BATCH RELEASE 187.00 MINUTES AVERAGE TIME PERIOD FOR BATCH RELEASES 141.66 MINUTES MINIMUM TIME PERIOD FOR A BATCH RELEASE 87.00 MINUTES AVERAGE STREAM FLOW DURING PERIODS OF RELEASE OF LIQUID EFFLUENT INTO A FLOWING STREAM :

1.65E+04 CFS O

.4

,r ^ g

(

)

TABLE 1-4B w-E.

I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 1996 Liquid Effluents - Batch Release Summary -

Unit: 2 Starting :

1-Jul-1996 Ending : 31-Dec-1996 LIQUID RELEASES NUMBER OF BATCH RELEASES 216 TOTAL TIME PERIOD FOR BATCH RELEASES 29440.00 MINUTES MAXIMUM TIME PERIOD FOR A BATCH RELEASE 188.00 MINUTES AVERAGE TIME PERIOD FOR BATCH RELEASES 136.30 MINUTES MINIMUM TIME PERIOD FOR A BATCH RELEASE 85.00 MINUTES AVERAGE STREAM FLOW DURING PERIODS OF RELEASE OF LIQUID EFFLUENT INTO A FLOWING STREAM :

1.65E+04 CFS ev u.n) i l

l

(: m v

r TABLE 1-5 MINIMUM DETECTABLE CONCENTRATIONS - LIQUID SAMPLE ANALYSES E. I. HATCH NUCLEAR PLANT JANUARY,1996 - DECEMBER,1996 The values in this table represent a priori Minimum Detectable Concentration (MDC) which are typically achieved in laboratory analyses of liquid radwaste samples.

RADIONUCLIDE MDC UNITS Mn-54 1.97E-08 uCi/ml Fe-59 3.94E-08 uCi/ml Co-58 1.59E-08 uCi/mi Co-60 1.72E-08 uCi/mi Zn-65 2.92E-08 uCi/mi Mo-99 1.20E-07 uCi/mi O

Cs-134 1.75E-08 uCi/mi Cs-137 1.62E-08 uCi/ml Ce-141 1.92E-08 uCi/ml Ce-144 8.83E-08 uCi/mi 1-131 1.43E-08 uCi/mi Xe-135 1.03E-08 uCi/mi Fe-55 2.34E-08 uCi/mi Sr-89 1.44E-08 uCi/ml Sr-90 8.50E-09 uCi/ml H-3 6.00E-07 uCi/mi O

i i

2 k

2.0 Gaseous Effluents 2.1 ODCM Specifications The ODCM Specifications presented in this section are for Unit 1 and Unit 2.

l 2.1.1 Dose Rate Limit i

The dose rate due to radioactive materials released in gaseous effluents from the site to areas at and beyond the SITE BOUNDARY shall be limited to the following:

k a.

For noble gases: Less than or equal to 500 mrems/yr. to the whole body j

and less than or equal to 3000 mrems/yr. to the skin and, b.

For lodine-131, lodine-133, tritium and for all radionuclides in

{

particulate form with half lives greater than 8 days: Less than or equal to i

1500 mrems/yr. to any organ.

l 2.1.2 Air Dose Due To Noble Gas i

The air dose due to noble gases released in gaseous effluents, from each unit, to i

areas at and beyond the SITE BOUNDARY, shall be limited to the following:

\\

5 a.

During any calendar quarter: Less than or equal to 5 mrads j

for gamma radiation and less than or equal to 10 mrads for beta l

radiation, and l

4 b..

During any calendar year: Less than or equal to 10 mrads for gamma radiation and less than or equal to 20 mrads for beta radiation.

i 2.1.3 Dose To Any Organ i

The dose to a MEMBER OF THE PUBLIC from lodine-131, lodine-133, tritium l

and all radionuclides in particulate form with half-lives greater than 8 days, in gaseous effluents released from each unit, to areas at and beyond the SITE BOUNDARY, shall be limited to the following.

a.

During any calendar quarter: Less than or equal to 7.5 mrems to any organ.

i j

b.

During any calendar year: Less than or equal to 15 mrems to any organ.

1 iO 1

l l

l 1

2.1.4 Total Fuel Cycle Dose Commitment (40CFR190)

O j

The annual (calendar year) dose or dose commitment to any MEMBER OF THE PUBLIC due to releases of radioactivity and to radiation from uranium fuel cycle -

sources shall be limited to less than or equal to 25 mrems to the whole body or l

to any organ, except the thyroid, which shall be limited to less than or equal to i

75 mrems.

2.2 Release Points of Gaseous Effluents Waste gas release at Plant Hatch is confined to four paths: main stack (also l

called the offgas vent), Unit 1 reactor building vent; Unit 2 reactor building j

[

vent, and the recombiner building vent. Each of these four paths is continuously i

monitored for gaseous radioactivity. Each is equipped with an integrating-type l

sample collection device for collecting particulates and ~ edines. Unless required i

more frequently under certain circumstances, samples are collected as follows:

I t

i 1.

Noble gas samples are collected by grab sampling monthly.

f 2.

Tritium samples are collected by grab sampling monthly.

{

3.

Radiciodine samples are collected by pulling the sample stream through

'n a charcoal cartridge over a 7-day period.

V J

l 4.

Particulates are collected by pulling the sample stream through a particulate filter over a 7-day period.

5.

The 7-day particulate filters above are analyzed for gross alpha activity.

I l-6.

Quarterly composite samples are prepared from the particulate filters collected over the previous quarter and the samples are analyzed for Sr-89 and Sr-90.

i Sample analyses results and release flow rates from the four release points form the basis for calculating released quantities of radionuclide-specific radioactivity, the dose rates associated with gaseous releases, and the cumulative doses for the current quarter and year. This task is normally performed with computer assistance.

The noble gas grab sample analysis results are used along with maximum expected release flow rates from each of the four vents to calculate monitor setpoints for the gaseous effluent monitors serving the four release points. Calculation of monitor setpoints is described in the ODCM.

O For each release period, released radioactivity, dose rates, and O

cumulative doses are calculated. Cumulative dose results are tabulated along with the percent of the ODCM limit for each release, for the current quarter and year.

2.3 Total Quantities of Radioactivity, Dose Rates, and Cumulative Doses The methods for determining release quantities of radioactivity, dose rates, and cumulative doses follow:

2.3.1 Fission and Activation Gas The released radioactivity is determined using sample analyses results collected as described above and the average release flow rates over the period represented by the collected sample.

Instantaneous dose rates due to noble gases, radiciodines, tritium, and particulates are calculated (with computer assistance). The calculated dose rates are compared to the dose rate limits specified in ODCM 3.1.2 for noble gases, radiciodine, tritium, and particulates. Dose rate calculation methodology is presented in the ODCM.

Beta and gamma air doses due to noble gases are calculated for the location in the unrestricted area with the potential for the highest exposure due to gaseous releases. Air doses are calculated for each release period and cumulative totals are kept for each unit for the calendar quarter and year. Cumulative air doses are compared to the dose limits specified in ODCM 3.1.3. The current percent of the ODCM limits are shown on the printout for each release period. Air dose calculation methodology is presented in the ODCM.

i 2.3.2 Radiolodine, Tritium and Particulate Releases l

Released quantities of radioiodines are determined using the weekly samples and release flow rates for the four release points. Radiciodine concentrations are determined by gamma spectroscopy.

Release quantities of particulates are determined using the weekly (filter) samples and release flow rates for the four release points. Gamma spectroscopy is used to quantify concentrations of principal gamma emitters.

O i

Q After each quarter, the particulate filters from each vent are combined, fused, and i

a strontium separation is performed. Since sample flows and vent flows are i

almost constant over each quarterly period the filters from each vent can be l

dissolved together. Decay corrections are performed back to the middle of the quarterly collection period. If Sr-89 or Sr-90 is not detected, MDC's are calculated. Strontium concentrations are input into the composite file of the s

computer and used for release dose rate and individual dose calculations.

I j

Tritium samples are obtained monthly from each vent by passing the sample stream through a cold trap. The grams of water vapor / cubic foot is measured upstream of the cold trap in order to alleviate the difficulties in determining water vapor collection efficiencies. The tritium samples are analyzed by an independent laboratory and the results are fumished in uCi/ml of water.

The tritium concentration in water is converted to the tritium concentration in air

[

and this value is input into the composite file of the computer and used in release, j

dose rate, and individual dose calculations.

I i

j Dose rates due to radiciodine, tritium and particulates are calculated for j.

a hypothetical child exposed, to the inhalation pathway at the location

~

in the unrestricted area where the potential dose rate is expected to be the highest. Dose rates are calculated, for each release point for each l-release period, and the total dose rates from both release points are i

compared to the dose rate limits specified in ODCM 3.1.2 i

j Individual doses due to radioiodine, tritium and particulates are calculated, j

for the controlling receptor, which is described in the ODCM.

Individual doses are calculated for each release period, and cumulative totals are kept for each unit, for the current calendar. quarter and year. Cumulative individual doses are compared to the dose limits specified in ODCM 3.1.4.

The current percent of ODCM limits are shown on the printout for each release period.

2.3.3 Gross Alpha Release The gross alpha release is computed each month by counting the particulate filters, for each week for gross alpha activity in a proportional counter. The four or I

five weeks' numbers are then recorded on a data sheet and the activity is summed at the end of the month. The summed activity is then divided by the total monthly volume to determine the concentration. This concentration is input into the composite file of the computer and used for release calculations.

O 2.4 Gaseous Effluent Release Data i

2.4.1 Methodology Regulatory Guide 1.21 Tables 1 A,18, and 1C are found in this report as Tables 2-1 A, 2-1 B, 2-1 C, 2-2A,,2-2B, 2-2C, 2-3A, 2-3B, 2-3C, and data is presented on i

a quarterly basis as required by Regulatory Guide 1.21 for all quarters.

To complete table 2-1 A,2-1B, and 2-1C, total release for each of the four l

categories (fission and activation gases, iodine's, particulates, and tritium) was j

divided by the number of seconds in the quarter to obtain a release rate in l

uCi/second for each category for each quarter. However, the percent of the j

ODCM limits are not applicable because we have no curie limits for gaseous releases. Applicable limits are expressed in terms of dose. Noble gases are limited as specified in ODCM 3.1.2. The other three categories (tritium, j

radiciodines, and particulates) are limited as a group as specified in ODCM 3.1.2.

Dose rates due to noble gas releases, and due to radioiodine, tritium, and particulates were calculated as part of the pre-release and post-release l

permits on individual permits. No limits were exceeded for this reporting period.

i Gross alpha radioactivity is reported in Table 2-1 A,2-1B, and 2-1C, as curies

. released in each quarter.

Limits for cumulative beta and gamma air doses due to noble gases are j

specified in ODCM 3.1.3. Cumulative air doses are presented in Table 2-4A j

and 2-4B, along with percent of ODCM limits.

i i

l Limits for cumulative individual doses due to radioiodine, tritium and j

particulates, are specified in ODCM 3.1.4. Cumulative individual doses are presented in Table 2-5A, and 2-5B, along with percent of ODCM limits.

l The total or maximum error associated with the effluent measurement will include the cumulative errors resulting from the total process of sampling and measurement. Due to the difficulty with assigning error terms i

for each parameter affecting the final measurement, detailed statistical evaluation of error is not suggested. The objective is to obtain an overall estimate of the error associated with measurements of radioactive materials released l

in liquid and gaseous effluents and solid waste Estimated errors are associated with counting equipment calibration, p

counting statistics, vent-flow rates, vent sample flow rates, non steady 3

j release rates, chemical yield factors and sample losses for such items as charcoal cartridges. - --.

Fission and activation total release was calculated from sample analysis results and release point flow rates.

Statistical error 60%

Counting equipment calibration 10%

Vent flow Rates 10%

Ncn steady release rates 20%

TOTAL ERROR 100 %

l-131 releases were calculated from each weekly sample:

Statistical error 60%

Counting equipmefit calibration 10%

Vent Flow Rates 10%

Vent Sample Flow Rates 10%

Non-Steady release rates 10%

Losses from charcoal cartridges 10%

TOTAL ERROR 110 %

Particulates with half lives greater than 8 days releases were calculated from sample analysis results and release point flow rates.

Statistical error 60%

O Counting equipment calibration 10%

Vent flow rates 10%

Vent sample flow rates 10%

Non steady release rates 10%

TOTAL ERROR 100%

Total tritium releases were calculated from sample analysis results and release point flow rates.

Water vapor in sample stream determination 20%

Vent flow rates 10%

Counting calibration and statistics 10%

Non-steady release rates 50 %

TOTAL ERROR 90 %

O 1

j

6 l

Gross Alpha radioactivity was calculated from sample analysis results and release point flow rates.

Statistical error 60%

Counting equipment calibration 10%

Vent flow rates 10%

Vent sample flow rates 10%

Non Steady release rates 10%

TOTAL ERROR 100 %

2.5 RadiologicalImpact Due to Gaseous Releases Dose rates due to noble gas release were calculated for the site in accordance with ODCM 3.1.2. Dose rates due to radioiodine, tritium, and particulates in gaseous releases were calculated in accordance with ODCM 3.1.2.

These dose rates were calculated as part of the pre-release and post release on individual release permits. No limits were exceeded for this reporting period.

Cumulative air doses due to noble gas releases were calculated for each unit in accordance with ODCM 3.1.4. These results are presented O

in Tables 2-6A,and 2-6B.

Dose rates and doses were calculated using the methodology presented in the ODCM.

2.6 Abnormal Releases There were no unplanned releases during this reporting period.

O --.

1 pag i

s i

i TABLC 2-1A V

E.

I. HATCH NUCLEAR PLANT

~~

ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 1996 Gaseous Effluents - Summation of All Releases Unit: 1 Starting :

1-Jan-1996 Ending : 30-Jun-1996 i

TYPE OF EFFLUENT UNITS QUARTER 1 QUARTER 2 EST. TOT ERROR %

A. FISSION & ACTIVATION PRODUCTS 1.

TOTAL RELEASE CURIES 5.69E+02 4.09E+02 1.00E+02 )

2. AVERAGE RELEASE RATE FOR PERIOD uCi/Sec 7.24E+01 5.21E+01

)

3. PERCENT OF APPLICABLE LIMIT 1

B. RADIOIODINES

1. TOTAL IODINE-131 CURIES 4.06E-03 5.39E-03 1.10E+02
2. AVERAGE RELEASE RATE FOR PERIOD uCi/Sec 5.16E-04 6.86E-04

./~'N.

3. PERCENT OF APPLICABLE LIMIT tV, C. PARTICULATES 1.

PARTICULATES (HALF-LIVES >8 DAYS)

CURIES 1.25E-03 1.81E-03 1.00E+02

2. AVERAGE RELEASE RATE FOR PERIOD uCi/Sec 1.59E-04 2.30E-04
3. PERCENT OF APPLICABLE LIMIT
4. GROSS ALPHA RADIOACTIVITY CURIES 5.18E-07 2.60E-07 D. TRITIUM 1.

TOTAL RELEASE CURIES 9.82E-01 1.02E+00 9.00E+01

2. AVERAGE RELEASE RATE FOR PERIOD uCi/Sec 1.25E-01 1.29E-01 3.

PERCENT OF APPLICABLE LIMIT Applicable limits are expressed in terms of dose.

See Tables 2-4A, 2-4B, 2-5A, and 2-5B of this report.

v 4

TABLE 2-1A 4

E. I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT. 1996 Gaseous Effluents - Summation-of All Releases Unit: 1 Starting :

1-Jul-1996 Ending : 31-Dec-1996 i

a TYPE OF EFFLUENT UNITS QUARTER 3 QUARTER 4 EST. TOT ERROR %

l 4

i A. FISSION & ACTIVATION PRODUCTS

~~~

~

~

~~ ~ ~~~~

~

~~

~

~

~~~~

[$ TbTkb kkbbkbE Cbkkkb 4$9bE bb b$5hh bb

[$bbk bh '

s

2. AVERAGE RELEASE RATE FOR PERIOD uCi/Sec 6.16E+01 8.20E+01
3. PERCENT OF APPLICABLE LIMIT a

4 B. RADIOIODINES 3

1. TOTAL IODINE-131 CURIES 2.89E-03 2.74E-03 1.10E+02

)

2. AVERAGE RELEASE RATE FOR PERIOD uCi/Sec 3.64E-04 3.45E-04

(

3. PERCENT OF APPLICABLE LIMIT 1

4 I

a i

C. PARTICULATES l

1.

PARTICULATES(HALF-LIVES >8 DAYS)

CURIES 4.53E-03 5.72E-03 1.00E+02

.?

2. AVERAGE RELEASE RATE FOR PERIOD uC1/Sec 5.70E-04 7.20E-04
3. PERCENT OF APPLICABLE LIMIT l
4. GROSS ALPHA RADIOACTIVITY CURIES 7.07E-07 4.56E-07 s

i' D. TRITIUM

1. TOTAL RELEASE CURIES 2.01E+00 1.31E+00 9.00E+01 i

j

2. AVERAGE RELEASE RATE FOR PERIOD uCi/Sec 2.53E-01 1.65E-01
3. PERCENT OF APPLICABLE LIMIT i

i I

Applicable limits are expressed in terms of dose.

See Tables

)

2-4A, 2-4B, 2-5A, and 2-5B of this report.

i A

)

4 l

i i 4

i I

)

TABLE 2-1B E. I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT. 1996 4

Gaseous Effluents - Summation of All Releades Unit: 2 4

Starting :

1-Jan-1996 Ending : 30-Jun-1996 TYPE OF EFFLUENT UNITS QUARTER 1 QUARTER 2 EST. TOT ERROR %

4 4

4 1

A.

FISSION & ACTIVATION PRODUCTS j

...................................................__........................... )

5

1. TOTAL RELEASE CURIES 5.86E+02 4.13E+02 1.00E+02 l
2. AVERAGE RELEASE RATE FOR PERIOD uC1/Sec 7.45E+01 5.25E+01
3. PERCENT OF APPLICABLE LIMIT 4

l j

B.

RADIOIODINES

1. TOTAL IODINE-131 CURIES 1.22E-02 8.53E-03 1.10E+02 i
2. AVERAGE RELEASE RATE FOR PERIOD uCi/Sec 1.55E-03 1.09E-03 i
3. PERCENT OF APPLICABLE LIMIT

\\,

\\

d i

l C. PARTICULATES 1.

PARTICULATES(HALF-LIVES >8 DAYS)

CURIES 2.81E-03 3.61E-02 1.00E+02

2. AVERAGE RELEASE RATE FOR PERIOD uCi/Sec 3.58E-04 4.59E-03 1

4

3. PERCENT OF APPLICABLE LIMIT
4. GROSS ALPHA RADIOACTIVITY CURIES 5.29E-07 4.03E-07 4

D. TRITIUM

1. TOTAL RELEASE CURIES 3.48E+00 3.28E+00 9.00E+01
2. AVERAGE RELEASE RATE FOR PERIOD uCi/Sec 4.43E-01 4.17E-01,
3. PERCENT OF APPLICABLE LIMIT i

l 1

Applicable limits are expressed in terms of dose.

See Tables 2-4A, 2-4B, 2-5A, and 2-5B of this report.

4 4 1 1

= - -.

e esk,)

TABLE 2-1B m

E.

I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 1996 Gaseous Effluents - Summation of All Releases Unit: 2 Starting :

1-Jul-1996 Ending : 31-Dec-1996 TYPE OF EFFLUENT UNITS QUARTER 3 QUARTER 4 EST. TOT )

ERROR %

1 1

j A.

FISSION & ACTIVATION PRODUCTS

1. TOTAL RELEASE CURIES 5.22E+02 6.00E+02 1.00E+02
2. AVERAGE RELEASE RATE FOR PERIOD uCi/Sec 6.56E+01 7.54E+01
3. PERCENT OF APPLICABLE LIMIT B. RADIOIODINES 1
1. TOTAL IODINE-131 CURIES 6.40E-03 6.98E 03 1.10E+02
2. AVERAGE RELEASE RATE FOR PERIOD uCi/Sec 8.05E-04 8.78E-04

[,

3. PERCENT OF APPLICABLE LIMIT C.

PARTICULATES

................................................................................ i i

1.

PARTICULATES(HALF-LIVES >8 DAYS)

CURIES 6.84E-03 6.70E-03 1.00E+02

2. AVERAGE RELEASE RATE FOR PERIOD uCi/Sec 8.61E-04 8.43E-04
3. PERCENT OF APPLICABLE LIMIT
4. GROSS ALPHA RADIOACTIVITY CURIES 5.64E-07 4.20E-07 D. TRITIUM
1. TOTAL RELEASE CURIES 4.71E+00 4.64E+00 9.00E+01
2. AVERAGE RELEASE RATE FOR PERIOD uCi/Sec 5.93E-01 5.84E-01
3. PERCENT OF APPLICABLE LIMIT Applicable limits are expressed in terms of dose.

See Tables 2-4A, 2-4B, 2-5A, and 2-5B of this report.

l I(,)

TABLE 2-1C E.

I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 1996 Gaseous Effluents. Summation of All Releas'es Unit: Site Starting :

1-Jan-1996 Ending : 30-Jun-1996 TYPE OF EFFLUENT UNITS QUARTER 1 QUARTER 2 EST. TOT i ERROR %

i A. FISSION & ACTIVATION PRODUCTS

1. TOTAL RELEASE CURIES 1.15E+03 8.22E+02 1.00E+02
2. AVERAGE RELEASE RATE FOR PERIOD uCi/Sec 1.47E+02 1.05E+02
3. PERCENT OF APPLICABLE LIMIT B. RADIOIODINES
1. TOTAL IODINE-131 CURIES 1.62E-02 1.39E-02 1.10E+02
2. AVERAGE RELEASE RATE FOR PERIOD uCi/Sec 2.06E-03 1.77E-03
3. PERCENT OF APPLICABLE LIMIT 4

C. PARTICULATES 1.

PARTICULATES(HALF-LIVES >8 DAYS)

CURIES 4.06E-03 3.79E-02 1.00E+02

2. AVERAGE RELEASE RATE FOR PERIOD uCi/Sec 5.17E-04 4.82E-03
3. PERCENT OF APPLICABLE LIMIT
4. GROSS ALPHA RADIOACTIVITY CURIES 1.05E-06 6.63E-07 D.

TRITIUM J

-1.

TOTAL RELEASE CURIES 4.46E+00 4.30E+00 9.00E+01

2. AVERAGE RELEASE RATE FOR PERIOD uCi/Sec 5.68E.01 5.46E-01
3. PERCENT OF APPLICABLE LIMIT

.............................. __............................................... i 1

Applicable limits are expressed in terms of dose.

See Tables 2-4A, 2-4B, 2-5A, and 2-5B of this report.

(

()

TABLE 2-1C E. I. HATCH NUCLEAR PLANT 1996 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -

Gaseous Effluents. Summation of All Releases Unit: Site Starting :

1-Jul.1996 Ending : 31-Dec-19.06 TYPE OF EFFLUENT UNITS QUARTER 3 QUARTER 4 EST. TOT ERROR %

i

)

A. FISS.ON & ACTIVATION PRODUCTS

1. TOTAL RELEASE CURIES 1.01E+03 1.25E+03 1.00E+02 I

i

2. AVERAGE RELEASE RATE FOR PERIOD uCi/Sec 1.27E+02 1.57E+02
3. PERCENT OF APPLICABLE LIMIT B. RADIOIODINES
1. TOTAL IODINE-131 CURIES 9.29E-03 9.73E-03 1.10E+02
2. AVERAGE RELEASE RATE FOR PERIOD uCi/Sec 1.17E-03 1.22E-03

)

3. PERCENT OF APPLICABLE LIMIT i

,g,,

C. PARTICULATES 1.

PARTICULATES(HALF-LIVES >8 DAYS)

CURIES 1.14E-02 1.24E-02 1.00E+02

2. AVERAGE RELEASE RATE FOR PERIOD uCi/Sec 1.43E-03 1.56E-03
3. PERCENT OF APPLICABLE LIMIT
4. GROSS ALPHA RADIOACTIVITY CURIES 1.27E-06 8.75E.07 D. TRITIUM
1. TOTAL RELEASE CURIES 6.72E+00 5.96E+00 9.00E+01
2. AVERAGE RELEASE RATE FOR PERIOD uCi/Sec 8.46E-01 7.49E-01
3. PERCENT OF APPLICABLE LIMIT Applicable limits are expressed in terms of dose.

See Tables 2-4A, 2-4B, 2-5A, and 2-5B of this report.

~

s I

i '

l a

.i

.. ~ -

..~.

I 9

l h

4 1

TABLE 2-2A*

~~

i-E. I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT. 1996 4

{

Gaseous Effluents-Elevated Level Releases Unit: 1 Stsrting :

1-Jan-1996 Ending : 30-Jun-1996

\\

i l

CONTINUOUS MODE l

BATCH MODE **

l NUCLIDES RELEASED l

UNIT l QUARTER 1 l QUARTER 2 l QUARTER 1 l QUARTER 2 l 1

i FISSION GASES KR-89 CURIES 0.00E+00 5.85E+00 0.00E+00 0.00E+00 1

XE-137 CURIES 2.23E+02 2.46E+02 0.00E+00 0.00E+00 XE-138 CURIES 1.06E+02 9.34E+01 0.00E+00 0.00E+00 XE-135M CURIES 4.15E+01 2.86E+01 0.00E+00 0.00E+00 KR-87 CURIES 6.79E+00 6.15E+00 0.00E+00 0.00E+00 AR-41 CURIES 0.00E+00 1.52E+00 0.00E+00 0.00E+00 KR-88 CURIES 8.05E-01 0.00E+00 0.00E+00 0.00E+00 KR-85M CURIES 5.36E+00 8.19E+00 0.00E+00 0.00E+00 XE-135 CURIES 5.30E+01 5.37E+00 0.00E+00 0.00E+00

(

XE-133M CURIES 4.76E+00 0.00E+00 0.00E+00 0.00E400

(

XE-133 CURIES 9.06E+01 2.86E+00

-0.00E+00 0.00E+00 TOTAL FOR PERIOD l

CURIES l 5.32E+02 l 3.98E+02 l 0.00E+00 l 0.00E+00 l IODINES I-132 CURIES 1.91E-03 0.00E+00 0.00E+00 0.00E+00 I-135 CURIES 6.38E-03 0.00E+00 0.00E+00 0.00E+00 I-133 CURIES 2.18E-02 7.04E-02 0.00E+00 0.00E+00 I-131 CURIES 3.56E-03

-5.05E-03 0.00E+00 0.00E+00 TOTAL FOR PERIOD l

CURIES l 3.37E-02 l 7.54E-02 l 0.00E+00 l'O.00E+00 l l l

PARTICULATES I-131 CURIES 2.64E-05 4.69E-05 0.00E+00 0.00E+00 BA-140 CURIES 8.06E-04 1.63E-03 0.00E+00 0.00E+00 CR-51 CURIES 0.00E+00 5.44E-06 0.00E+00 0.00E+00 CE-141 CURIES 2.00E-06 9.63E-06 0.00E+00 0.00E+00 SR-89 CURIES 3.59E-04 7.48E-06 0.00E+00 0.00E+00

.CO-58 CURIES 0.00E+00 6.73E-07 0.00E+00 0.00.E+00 ZN-65 CURIES 1.45E-06 1.81E-05 0.00E+00 0.00E+00 CE-144 CURIES 1.09E-05 2.44E-05 0.00E+00 0.00E+00 I

MN-54 CURIES 0.00E+00 1.16E-06 0.00E+00 0.00E+00 CS-134 CURIES 1.38E-07 0.00E+00 0.00E+00 0.00E+00 O

CO-60 CURIES 0.00E+00 3.48E-06 0.00E+00 0.00E+00 s-SR-90 CURIES 7.38E-06 1.48E-07 0.00E+00 0.00E+00 CS-137 CURIES 6.65E-06 1.05E-05 0.00E+00 0.00E+00 TOTAL FOR PERIOD l

CURIES l 1.22E-03 l 1.76E-03 l 0.00E+00 l 0.00E+00 l

, i l

-.. ~.

/"'N U

TABLE 2-2A*

~~~

E.

I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE. EFFLUENT RELEASE REPORT. 1996 Gaseous Effluents-Elevated Level Releases Unit: 1 Starting :

1-Jan-1996 Ending : 30-Jun-1996 1

l CONTINUOUS MODE l

BATCH MODE **

l NUCLIDES RELEASED l

UNIT l QUARTER 1 l QUARTER 2 l QUARTER 1 l QUARTER 2 l PARTICULATES G-ALPHA CURIES 2.25E-08 1.69E-08 0.00E+00 0.00E+00 H-3 CURIES 1.81E-01 2.37E-01 0.00E+00 0.00E+00

\\

Zeroes in this table indicate that no radioactivity was present

,j (}

at detectable levels.

See Table 2-7 for typical minimum

(_,

detectable concentrations.

There are no batch mode radioactive gaseous release pathways at Plant Hatch.

i I

l i

f l

I l

[

1 i

s 4

i 4: g-s

\\

TABLE 2-2A*

""~

E.

I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT

- 1996 Gaseous Effluents-Elevated Level Releases Unit:

Starting :

1-Jul-1996 Ending : 31-Dec-1996 l

CONTINUOUS MODE l

BATCH MODE **

l l

9 i

NUCLIDES RELEASED l

UNIT l QUARTER 3 l QUARTER 4 l QUARTER 3 l QUARTER 4 l FISSION GASES

)

KR-89 CURIES 2.10E+01 0.00E+00 0.00E+00 0.00E+00 I

XE-137 CURIES 2.66E+02 3.74E+02 0.00E+00 0.00E+00 i

XE-138 CURIES 1.10E+02 1.40E+02 0.00E+00 0.00E+00 XE-135M CURIES 3.48E+01 4.56E+01 0.00E+00 0.00E+00 KR-87 CURIES 5.62E+00 6.68E+00 0.00E+00 0.00E+00 AR-41 CURIES 2.97E-01 3.88E-01 0.00E+00 0.00E+00 1

KR-85M CURIES 2.40E+00 4.45E+00 0.00E+00 0.00E+00 XE-135 CURIES 6.26E+00 8.22E+00 0.00E+00 0.00E+00 XE-133 CURIES 5.69E+00 1.32E+01 0.00E+00 0.00E+00

\\

KR-85 CURIES 0.00E+00 0.00E+00 0.00E+00 0.00E+00 f

',,)

TOTAL FOR PERIOD l

CURIES l 4.52E+02 l 5.92E+02 l 0.00E+00 l 0.00E+00-l i

4 IODINES I-133 CURIES 4.01E-02 3.25E-02 0.00E+00 0.00E+00 i

j I-131 CURIES 2.48E-03 1.96E-03 0.00E+00 0.00E+00 i

TOTAL FOR PERIOD l

CURIES l 4.25E-02 l 3.45E-02 l 0.00E+00 l 0.00E+00 l 1

PARTICULATES I-131 CURIES 8.28E-05 8.59E-05 0.00E+00 0.00E+00 BA-140 CURIES 3.22E-03 3.95E-03 0.00E+00 0.00E+00 l_

CE-141 CURIES 1.23E-05 9.568-06 0.00E+00 0.00E+00 SR-89 CURIES 1.03E-03 9.66E-04 0.00E+00 0.00E+00 ZN-65 CURIES 5.06E-06 7.00E-07 0.00E+00 0.00E+00 CE-144 CURIES 4.69E-05 5.83E-05 0.00E+00 0.00E+00 SR-90 CURIES 3.96E-11 1.36E-05 0.00E+00 0.00E+00 i

CS-137 CURIES 2.01E-05 2.34E-05 0.00E+00 0.00E+00 TOTAL FOR PERIOD l

CURIES l 4.42E-03 l 5.10E-03 l 0.00E+00 l 0.00E+00 l g

- (

G-ALPHA CURIES 2.20E-08 2.55E-08 0.00E+00 0.00E+00 H-3 CURIES 4.67E-01 2.82E-01 0.00E+00 0.00E+00

l

\\

1 i

l i

TABLE 2-2A*

~

E.

I. HATCH NUCLEAR PLANT l

ANNUAL RADIOACTIV3 EFFLUENT RELEASE REPORT

- 1996 i

Gaseous Effluents-Elevated Level Releases 1

Unit: 1 Starting :

1-Jul-1996 Ending : 31-Dec-1996 1

i l

CONTINUOUS MODE l

BATCH MODE **

l NUCLIDES RELEASED l

UNIT l QUARTER 3 l QUARTER 4 l QUARTER 3 l QUARTER 4 l l

j i

l l

Zeroes in this table indicate that no radioactivity was present l

at detectable levels.

See Table 2 7 for typical minimum detectable concentrations.

There are no batch mode radioactive gaseous release pathways at Plant Ratch.

l l

s-1 k

l 1

i I

i I

i 4

i l

i O4 i

TABLE 2-2B*

E. I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT

- 1996 Gaseous Effluents-Elevated Level Releases Unit: 2 Starting :

1-Jan-1996 Ending : 30-Jun-2996 l

CONTINUOUS MODE l

BATCH MODE **

l NUCLIDES RELEASED l

UNIT l QUARTER 1 l QUARTER 2 l QUARTER 1 l QUARTER 2 l FISSION GASES KR-89 CURIES 0.00E+00 5.85E+00 0.00E+00 0.00E+00 XE-137 CURIES 2.23E+02 2.46E+02 0.00E+00 0.00E+00 XE-136 CURIES 1.30E+02 9.34E+01 0.00E+00 0.00E+00 XE-135M CURIES 4.90E+01 3.05E+01 0.00E+00 0.00E+00

{

KR-87 CURIES 8.27E+00 6.15E+00 0.00E+00 0.00E+00 AR-41 CURIES 0.00E+00 1.52E+00 0.00E+00 0.00E+00 KR-88 CURIES 8.05E-01 0.00E+00 0.00E+00 0.00E+00 KR-85M CURIES 6.31E+00 8.19E+00 0.00E+00 0.00E+00 XE-135 CURIES 5.43E+01 5.67E+00 0.00E+00 0.00E+00 XE-133M CURIES 4.76E+00 0.00E+00 0.00E+00 0.00E+00 XE-133 CURIES 9.22E+01 3.23E+00 0.00E+00 0.00E+00

................................................................................ )

TOTAL FOR PERIOD l

CURIES l 5.68E+02 l 4.00E+02 l 0.00E+00 l 0.00E+00 l IODINES I-132 CURIES 1.92E-03 0.00E+00 0.00E+00 0.00E+00 I-135 CURIES 7.65E-03 6.19E-04 0.00E+00 0.00E+00 I-133 CURIES 3.31E-02 7.23E-02 0.00E+00 0.00E+00 I-131 CURIES 7.62E-03 6.02E-03 0.00E+00 0.00E+00

................................................................................ i TOTAL FOR PERIOD l

CURIES l 5.03E-02 l 7.89E-02 l 0.00E+00 l 0.00E+00 l PARTICULATES I-131 CURIES 3.15E-05 4.72E-05 0.00E+00 0.00E+00 BA-140 CURIES 8.43E-04 1.68E-03 0.00E+00 0.00E+00 CR-51 CURIES 0.00E+00 8.45E-06 0.00E+00 0.00E+00 CE-141 CURIES 2.20E-06 9.77E-06 0.00E+00 0.00E+00 NB-95 CURIES 0.00E+00 1.72E-07 0.00E+00 0.00E+00 FE-59 CURIES 0.00E+00 6.54E-07 0.00E+00 0.00E+00 SR-89 CURIES 3.60E-04 7.94E-06 0.00E+00 0.00E+00 CO-58 CURIES 0.00E+00 1.06E-06 0.00E+00 0.00E+00 ZN-65 CURIES 2.78E-06 2.09E-05 0.00E+00 0.00E+00 CE-144-CURIES 1.16E-05 2.47E-05 0.00E+00 0.00E+00 MN-54 CURIES 0.00E+00 2.15E-06 0.00E+00 0.00E+00

\\

CS-134 CURIES 1.38E-07 0.00E+00 0.00E+00 0.00E+00 CO-60 CURIES 0.00E+00 4.57E-06 0.00E+00 0.00E+00 SR-90 CURIES 7.39E-06 1.55E-07 0.00E+00 0.00E+00 CS-137 CURIES 7.04E-06 1.13E-05 0.00E+00 0.00E+00

. ~. -

_ ~. -.

1 l

TABLE 2-2B*

~

E. I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT

  • 1996 Gaseous Effluents-Elevated Level Releases Unit: 2 Starting :

1-Jan-1996 Ending : 30-Jan-1996 t

i l

l CONTINUOUS MODE l

BATCH MODE **

l 4

)

NUCLIDES RELEASED l

UNIT l QUARTER 1 l QUARTER 2 l QUARTER 1 l QUARTER 2 l l

l PARTICULATES TOTAL FOR PERIOD l

CURIES l 1.26E-03 l 1.82E-03 l 0.00E+00 l 0.00E+00 l

\\

l G-ALPHA CURIES 2.51E-08 2.09E-08 0.00E+00 0.00E+00 H.3 CURIES 2.80E-01 2.84E-01 0.00E+00 0.00E+00 t

l 2eroes in this table indicate that no radioactivity was present j

\\

at detectable levels.

See Table 2-7 for typical minimum i

detectable concentrations.

)

i There are no batch mode radioactive gaseous release pathways j

at Plant Hatch.

i 1

I i

i I

4 1

i r TABLE 2-2B*

~~~

E.

I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT.-1996 Gaseous Effluents-Elevated Level Releases e

Unit: 2 Starting :

1-Jul-1996 Ending : 31-Dec-1996

[

l CONTINUOUS MODE l

BATCH MODE *'*

l f NUCLIDES RELEASED l

UNIT l QUARTER 3 l QUARTER 4 l QUARTER 3 l QUARTER 4 l FISSION GASES KR-89 CURIES 2.10E+01 0.00E+00 0.00E+00 0.00E+00 l

XE-137 CURIES 2.66E+02 3.74E+02 0.00E+00 0.00E+00 XE-138 CURIES 1.10E+02 1.40E+02 0.00E+00 0.00E+00 XE-135M CURIES 3.48E+01 4.56E+01 0.00E+00 0.00E+00 KR-87 CURIES 5.62E+00 6.68E+00 0.00E+00 0.00E+00 AR-41 CURIES 2.97E-01 3.88E-01 0.00E+00 0.00E+00 i

KR-85M CURIES 2.40E+00 4.45E+00 0.00E+00 0.00E+00 XE-135 CURIES 6.26E+00 8.22E+00 0.00E+00 0.00E+00 XE-133 CURIES 5.693+00 1.32Et01 0.00E+00 0.00E+00

~%

KR-85 CURIES 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TOTAL FOR PERIOD l

CURIES l 4.52E+02 l 5.92E+02 l 0.00E+00 l 0.00E+00 l IODINES I-133 CURIES 4.01E-02 3.25E-02 0.00E+00 0.00E+00 I-131 CURIES 2.48E-03 1.96E-03 0.00E+00 0.00E+00 TOTAL FOR PERIOD l

CURIES l 4.25E-02 l 3.45E-02 l 0.00E+00 l 0.00E+00 l PARTICULATES I-131 CURIES 8.28E-05 8.59E-05 0.00E+00 0.00E+00 BA-140 CURIES 3.22E-03 3.95E-03 0.00E+00 0.00E+00 CE-141 CURIES 1.23E-05 9.56E-06 0.00E+00 0.00E+00 SR-89 CURIES 1.03E-03 9.66E-04 0.00E+00 0.00E+00 ZN-65 CURIES 5.06E-06 7.00E-07 0.00E+00 0.00E+00 CE-144 CURIES 4.69E-05 5.83E-05 0.00E+00 0.00E+00 SR-90 CURIES 3.96E-11 1.36E-05 0.00E+00 0.00E+00 CS-137 CURIES 2.01E-05 2.34E-05 0.00E+00 0.00E+00 TOTAL FOR PERIOD l

CURIES l 4.42E-03 l 5.10E-03 l 0.00E+00 l 0.00E+00 l

\\

G-ALPHA CURIES 2.20E-08 2.55E-08 0.00E+00 0.0DE+00 s~s/

H-3 CURIE'1 4.67E-01 2.82E-01 0.00E+00 0.00E+00

. - ~ _ _ -,

. -. -. - _.. -. - - _ - _.. -... - _.....~.

G r

l-t t

i D0 TABLE 2-2B*

E. I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT

-1996 i

Gaseous Effluents-Elevated Level Releases Unit: 2 Starting :

1-Jul-1996 Ending : 31-Dec-1996 I

l CONTINUOUS MODE l

BATCH NODE **

l )

NUCLIDES RELEASED l

UNIT l QUARTER 3 l QUARTER 4 l QUARTER 3 l QUARTER 4 l l

................................___............................................. s f

l Zeroes in this table indicate that no radioactivity was present at detectable levels.

See Table 2-7 for typical minimum detectable concentrations.

l There are no batch mode radioactive gaseous release pathways l

at Plant Hatch.

I l

l k

J h 4 4

,_._-__..r

. ~ _.._ _ ~ -

t TABLE 2-2C*

~~~

E.

I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT. 1996 Gaseous Effluents-Elevated Level Releases Unit: Site Starting :

1-Jan-1996 Ending. 30-Jun-1996 l

CONTINUOUS MODE l

BATCH MODE **

l NUCLIDES RELEASED l

UNIT l QUARTER 1 l QUARTER 2 l QUARTER 1 l QUARTER 2 l r

FISSION GASES i

XE-137 CURIES 4.46E+02 4.92E+02 0.00E+00 0.00E+00 XE-138 CURIES 2.36E+02 1.87E+02 0.00E+00 0.00E+00 XE-135M CURIES 9.05E+01 5.91E+01 0.00E+00 0.00E+00 KR-87 CURIES 1.51E+01 1.23E+01 0.00E+00 0.00E+00 AR-41 CURIES 0.00E+00 3.04E+00 0.00E+00 0.00E+00 KR-88 CURIES 1.61E+00 0.00E+00 0.00E+00 0.00E+00 i

KR-85M CURIES 1.17E+01 1.64E+01 0.00E+00 0.00E+00 XE-135 CURIES 1.07E+02 1.10E+01 0.00E+00 0.00E+00

(~

XE-133M CURIES 9.51E+00 0.00E+00 0.00E+00 0.00E+00 l

t XE-133 CURIES 1.83E+02 6.09E+00 0.00E+00 0.00E+00 TOTAL FOR PERIOD l

CURIES l 1.10E+03 l 7.98E+02 l 0.00E+00 l 0.00E+00 l IODINES l

I-132 CURIES 3.83E-03 0.00E+00 0.00E+00 0.00E+00 j

I-135 CURIES 1.40E-02 6.19E-04 0.00E+00 0.00E+00 1

I-133 CURIES 5.49E-02 1.43E-01 0.00E+00 0.00E+00 I-131 CURIES 1.12E-02 1.11E-02 0.00E+00 0.00E+00 TOTAL FOR PERIOD l

CURIES l 8.40E-02 l 1.54E-01 l 0.00E+00 l 0.00E+00 l PARTICULATES I-131 CURIES 5.79E-05 9.41E-05 0.00E+00 0.00E+00 BA-140 CURIES 1.65E-03 3.31E-03 0.00E+00 0.00E+00 CR-51 CURIES 0.00E+00 1.39E-05 0.00E+00 0.00E+00 CE-141 CURIES 4.20E-06 1.94E-05 0.00E+00 0.00E+00 NB-95 CURIES 0.00E+00 1.72E-07 0.00E+00 0.00E+00 FE-59 CURIES 0.00E+00 6.54E-07 0.00E+00 0.00E+00 i

SR-89 CURIES 7.19E-04 1.54E-05 0.00E+00 0.00E+00 i

CO-58 CURIES 0.00E+00 1.73E-06 0.00E+00 0.00E+00 ZN-65 CURIES 4.23E-06 3.90E-05 0.00E+00 0.00E+00 l

CE-144 CURIES 2.25E-05 4.91E-05 0.00E+00 0.00E+00 MN-54 CURIES 0.00E+00 3.31E-06 0.00E+00 0.00E+00

\\

CS-134 CURIES 2.75E-07 0.00E+00 0.00E+00 0.00E+00 CO-60 CURIES 0.00E+00 8.05E-06 0.00E+00 0.00E+00

)

SR-90 CURIES 1.48E-05 3.03E-07 0.00E+00 0.00E+00 CS-137 CURIES 1.37E-05 2.18E-05 0.00E+00 0.00E+00 O

TABLE 2-2C*

~

E. I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT

  • 1996 Gaseous Effluents-Elevated Level Releases Unit: Site Starting :

1-Jan-1996 Ending : 30-Jun-1996 l

CONTINUOUS MODE l

BATCH MODE **

l NUCLIDES RELEASED l

UNIT lQUILRTER 1 l QUARTER 2 l QUARTER 1 l QUARTER 2 l i

PARTICULATES TOTAL FOR PERIOD l

CURIES l 2.48E.03 l 3.58E-03 l 0.00E+00 l 0.00E+00 lI i

j G-ALPHA CURIES 4.76E-08 3.78E-08 0.00E+00 0.00E+00 i

H-3 CURIES 4.61E-01 5.21E-01 0.00E+00 0.00E+00

/'

(

Zeroes in this table indicate that no radioactivity was present at detectable levels.

See Table 2-7 for typical minimum detectable concentrations.

i t

I There are no batch mode radioactive gaseous release pathways at Plant Hatch.

kv) i 1

(V"'S 1

TABLE 2-2C*

1 E. I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT

' 1996 I

Gaseous Effluents-Elevated Level Releases i

Unit: Site Starting.

1-Jul-1996 Ending : 31-Dec-1996 l

CONTINUOUS MODE l

BATCH MODE **

l NUCLIDES RELEASED l

UNIT l QUARTER 3 l QUARTER 4 l QUARTER 3 l QUARTER 4 l FISSION GASES KR.89 CURIES 4.19E+01 0.00E+00 0.00E+00 0.00E+00 XE-137 CURIES 5.33E+02 7.48E+02 0.00E+00 0.00E+00 XE-138 CURIES 2.19E+02 2.80E+02 0.00E+00 0.00E+00 XE-135M CURIES 6.96E+01 9.12E+01 0.00E+00 0.00E+00 KR-87 CURIES 1.12E+01 1.34E+01 0.00E+00 0.00E+00 AR-41 CURIES 5.94E-01 7.77E-01 0.00E+00 0.00E+00 KR-85M CURIES 4.79E+00 8.90E+00 0.00E+00 0.00E+00 XE-135 CURIES 1.25E+01 1.64E+01 0.00E+00 0.00E+00 1

XE-133 CURIES 1.14E+01 2.64E+01 0.00E+00 0.00E+00 Q(\\

KR-85 CURIES 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TOTAL FOR PERIOD l

CURIES l 9.04E+02 l 1.18E+03 l 0.00E+00 l 0.00E+00 l IODINES I-133 CURIES 8.01E-02 6.50E-02 0.00E+00 0.00E+00 I-131 CURIES 4.96E-03 3.92E-03 0.00E+00 0.00E+00 TOTAL FOR PERIOD l

CURIES l 8.51E-02 l 6.89E-02 l 0.00E+00 l 0.00E+00 l PARTICULATES I-131 CURIES 1.66E-04 1.72E-04 0.00E+00 0.00E+00 l

BA-140 CURIES 6.44E-03 7.89E-03 0.00E+00 0.00E+00 CE-141 CURIES 2.46E-05 1.91E-05 0.00E+00 0.00E+00 SR-89 CURIES 2.07E-03 1.93E-03 0.00E+00 0.00E+00 ZN-65 CURIES 1.01E-05 1.40E-06 0.00E+00 0.00E+00 CE-144 CURIES 9.39E-05 1.17E-04 0.00E+00 0.00E+00 SR-90 CURIES 7.91E-11 2.72E-05 0.00E+00 0.00E+00 CS-137 CURIES 4.02E-05 4.68E-05 0.00E+00 0.00E+00 TOTAL FOR PERIOD l

CURIES l 8.84E-03 l 1.02E-02 l 0.00E+00 l 0.00E+00 l G-ALPHA CURIES 4.40E-08 5.10E-08 0.00E+00 0.00E+00

(

H-3 CURIES 9.34E-01 5.64E-01 0.00E+00 0.00E+00

l i

r 4

v TABLE 2-2C*

~

E. I. HATCH NUCLEAR PLANT 1

ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT. 1996 l

Gaseous Effluents-Elevated Level Releases Unit: Site' i

Starting :

1-Jul-1996 Ending : 31-Dec-1996 j

l l

CONTINUOUS MODE l

BATCH MODE **

l l

NUCLIDES RELEASED l

UNIT l QUARTER 3 l QUARTER 4 jQUARTER 3 l QUARTER 4 l Zeroes in this table indicate that no radioactivity was present at detectable levels.

See Table 2-7 for typical miniitt.im detectable concentrations.

There-are no batch mode radioactive gaseous release pathways at Plant Hatch, l

i i

l 1

l J

J )

-. - _ ~-

i e

l

!!(

TABLE 2-3A*

~

E. I. HATCH NUCLEAR PLANT

'NUAL RADIOACTIVE EFFLUENT RELEASE REPORT. - 1996 Gaseous Effluents-Ground Level Releases l

Unit: 1 Starting :

1-Jan.1996 Ending : 30-Jun-1996

{

L t

l CONTINUOUS MODE

]

BATCH MODE **

l NUCLIDES RELEASED l

UNIT l QUARTER 1 l QUARTER 2 l QUARTER 1 l QUARTER 2 l p

lI' FISSION GASES t

XE-135M CURIES 5.95E-01 0.00E+00 0.00E+00-0.00E+00 KR-87 CURIES 0.00E+00 3.52E-02 0.00E+00 0.00E+00 KR-85M CURIES 0.00E+00 6.75E-03 0.00E+00 0.00E+00 XE-135 CURIES 2.38E+01 8.18E+00 0.00E+00 0.00E+00 XE-133 CURIES 1.24E+01 3.34E+00 0.00E+00 0.00E+00 TOTAL FOR PERIOD l

CURIES l 3.68E+01 l 1.16E+01 l 0.00E+00 l 0.00E+00 l

/^

IODINES t,

I-133 CURIES 4.97E-03 4.32E.03 0.00E+00 0.00E+00 I-131 CURIES 4.65E-04 2.87E-04 0.00E+00 0.00E+00 L

TOTAL FOR PERIOD l

CURIES l 5.43E-03 l 4.61E-03 l 0.00E+00 l 0.00E+00 l j i

I PARTICULATES I-131 CURIES 3.61E-06 4.05E-06 0.00E+00 0.00E+00 BA-140 CURIES 6.24E-06 1.55E-05 0.00E+00 0.00E+00 CR-51 CURIES 0.00E+00 6.82E-06 0.00E+00 0.00E+00 CE-141 CURIES 7.88E-07 0.00E+00 0.00E+00 0.00E+00 i

RU-103 CURIES 8.19E-06 8.73E-06 0.00E+00 0.00E+00 l

SR-89 CURIES 7.81E-06 7.05E-06 0.00E+00 0.00E+00

ZN-65 CURIES 2.35E-06 3.96E-06 0.00E+00 0.00E+00.

MN-54 CURIES 0.00E+00 1.39E-06 0.00E+00 0.00E+00 CO-60 CURIES 0.00E+00 1.62E-06 0.00E+00 0.00E+00 i

SR-90 CURIES 9.80E.08 2.52E-09 0.00E+00 0.00E+00 1

CS-137 CURIES 1.96E-08 0.00E+00 0.00E+00 0.00E+00 TOTAL FOR' PERIOD l

CURIES l 2.91E-05 l 4.91E-05 l 0.00E+00 l 0.00E+00 l

................................................................................ i G-ALPHA CURIES 4.95E-07 2.43E-07 0.00E+00 0.00E+00 H-3 CURIES 8.01E-01 7.793-01 0.00E+00 0.00E+00

-(.

l l i

i i

t

\\'

TABLE 2-3A*

E.

I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT.1996 Gaseous Effluents-Ground Level Releases i

Unit: 1 Starting.:

1-Jan-1996 Ending : 30-Jun-1996 l

l CONTINUOUS MODE l

EATCH MODE **

l NUCLIDES RELEASED l

UNIT l QUARTER 1 l QUARTER 2 l QUARTER 1 l QUARTER 2 l l

e Zeroes in this table indicate that no radioactivity was present at detectable levels.

See Table 2-7 for typical minimum detectable concentrations.

i There are no batch mode radioactive gaseous release pathways at Plant Hatch.

l

+

f I

i 0

r P

k-TABLE 2-3A*

~~

E. I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT

' 1996 Gaseous Effluents-Ground Level Releases Unit: 1 Starting :

1-Jul-1996 Ending : 31-Dec-1996 i

l CONTINUOUS MODE l

BATCH MODE **

l l

, NUCLIDES RELEASED l

UNIT l QUARTER 3 l QUARTER 4 l QUARTER 3 l QUARTER 4 l t

FISSION GASES XE-135M CURIES 1.62E+01 1.29E+01 0.00E+00 0.00E+00 XE-135 CURIES 2.19E+01 3.59E+01 0.00E+00 0.00E+00 XE-133 CURIES 0.00E+00 1.08E+01 0.00E+00 0.00E+00

~

hbbkLhbkPbkkbb

'}

Cbkkhb

} b$bkb b5 } b$bbb b5 } b$bbb bb }"b$bbb bb }

1 IODINES

(~'s I-133 CURIES 6.85E-03 1.58E-02 0.00E+00 0.00E+00 I-131 CURIES 3.30E-04 6.97E-04 0.00E+00 0.00E+00 TOTAL FOR PERIOD l

CURIES l 7.18E-03 l 1.65E-02 l 0.00E+00 l 0.00E+00 }

................................................................................ l PARTICULATES I-131 CURIES 0.00E+00 1.92E-06 0.00E+00 0.00E+00 BA-140 CURIES 5.25E-05 3.89E-05 0.00E+00 0.00E+00 CR-51 CURIES 0.00E+00 2.44E-05 0.00E+00 0.00E+00 j

SR-89.

CURIES 2.28E-05 5.36E-04 0.00E+00 0.00E+00 CO-58' CURIES 2.36E-06 1.23E-06 0.00E+00 0.00E+00 ZN-65 CURIES 1.77E-05 1.02E-05 0.00E+00 0.00E+00 MN-54 CURIES 1.05E-06 0.00E+00 0.00E+00 0.00E+00 CO-60 CURIES 1.08E-05 6.94E-07 0.00E+00 0.00E+00 SR-90 CURIES 2.59E-07 2.17E-06 0.00E+00 0.00E+00 CS-137 CURIES 2.17E-06 0.00E+00 0.00E+00 0.00E+00 TOTAL FOR PERIOD l

CURIES l 1.10E-04,l 6.16E-04 l 0.00E+00 l 0.00E+00 l l

G-ALPHA CURIES 6.85E-07 4.30E-07 0.00E+00 0.00E+00 H-3 CURIES 1.55E+00 1.03E+00 0.00E+00 0.00E+00 6 p

.m

_ _.. ~.

l i.

t 1

l TABLE 2-3A*

~

1 E.

I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT

'1996 Gaseous Effluents-Ground Level Releases Unit: 1 Starting :

1-Jul-1996 Ending t 31-Dec-1996 i

t I

l CONTINUOUS NODE l

BATCH MODE **

l NUCLIDES RELEASED l

UNIT l QUARTER 3 l QUARTER 4 l QUARTER 3 l QUARTER 4 l [

1 2

Zeroes in this table indicate that no radioactivity was present 4

at detectable levels.

See Table 2-7 for typical minimum i

detectable concentrations.

1 i

There are no batch mode radioactive gaseous release pathways j

at Plant Hatch.

3 s_;-

4 k

4 I

l l

I 4

1 I

1 a

1 1

I i

4 J

1 i

i

' ~\\

(_/

)

i

/~'\\.

U TABLE 2-3B*

~

E.

I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT '1996 Gaseous Effluents-Ground Level Releases Unit: 2 Starting :

1-Jan-1996 Ending : 30-Jun-1996 l

CONTINUOUS MODE l

BATCH MODE **

l NUCLIDES RELEASED l

UNIT l QUARTER 1 l QUARTER 2 l QUARTER 1 l QUARTER 2 l FISSION GASES XE-135 l

CURIES l 1.73E+01 l 1.23E+01 l 0.00E+00 l 0.00E+00 l TOTAL FOR PERIOD l

CURIES l 1.73E+01 l 1.23E+01 l 0.00E+00 l 0.00E+00 l IODINES I-135 CURIES 1.72E-03 0.00E+00 0.00E+00 0.00E+00 I-133 CURIES 8.19E-02 5.63E 02 0.00E+00 0.00E+00 I-131 CURIES 4.14E-03 2.28E-03 0.00E+00 0.00E+00

\\

TOTAL FOR PERIOD l

CURIES l 8.77E-02 l 5.86E-02 l 0.00E+00 l 0.00E+00 l PARTICULATES I-131 CURIES 3.77E-04 1.79E-04 0.00E+00 0.00E+00 BA-140 CURIES 7.81E-04 3.90E-04 0.003+00 0.00E+00 CE-141 CURIES 4.17E-05 1.10E-05 0.00E+00 0.00E+00 RU-103 CURIES 0.00E+00 3.38E-06 0.00E+00 0.00E+00 SR-89 CURIES 3.44E-04 3.35E-02 0.00E+00 0.00E+00 SR-90 CURIES 6.27E-06 2.25E.04 0.00E+00 0.00E+00 TOTAL FOR PERIOD l

CURIES l 1.55E-03 l 3.43E-02 l 0.00E+00 l 0.00E+00 l G-ALPHA CURIES 5.04E-07 3.82E-07 0.00E+00 0.00E+00 H-3 CURIES 3.20E+00 3.00E+00 0.00E+00 0.00E+00 Zeroes in this table indicate that no radioactivity was present at detectable levels.

See Table 2-7 for typical minimum detectable concentrations.

\\

There are no batch mode radioactive gaseous release pathways at Plant Hatch.

i

)

TABLE 2-3B*

i

~

E.

I. HATCH NUCLEAR PLANT ANNUAL RADICACTIVE EFFLUENT RELEASE REPORT.-1996 Gaseous Effluents-Ground Level Releases l

Unit: 2 Starting :

1-Jul-1996 Ending : 31-Dec-1996 i

l I

l CONTINUOUS MODE l

BATCH MODE **

l NUCLIDES RELEASED l

UNIT l QUARTER 3 l QUARTER 4 l QUARTER 3 l QUARTER 4 l FISSION GASES i

................................................................................I XE-135 CURIES 0.00E+00 7.58E+00 0.00E+00 0.00E+00 XE-133 CURIES 7.00E+01 0.00E+00 0.00E+00 0.00E+00 TOTAL FOR PERIOD l

CURIES l 7.00E+01 l 7.58E+00 l 0.00E+00 l 0.00E+00 l IODINES I-132 CURIES 1.49E-03 0.00E+00 0.00E+00 0.00E+00

/~')

I-135 CURIES 8.22E-04 0.00E+00 0.00E+00 0.00E+00 k,/

I-133 CURIES 8.76E-02 1.02E-01 0.00E+00 0.00E+00 s

I-131 CURIES 3.58E-03 4.44E-03 0.00E+00 0.00E+00 TOTAL FOR PERIOD l

CURIES l 9.35E-02 l 1.07E.01 l 0.00E+00 l 0.00E+00 l PARTICULATES BA-140 CURIES 7.24E-04 1.04E-03 n.00E+00 0.00E+00 CE-141 CURIES 4.33E-05 1.26E-05 0.00E+00 0.00E+00 l

NB-95 CURIES 1.29E-06 0.00E+00 0.00E+00 0.00E+00 SR-89 CURIES 1.39E-03 2.82E-05 0.00E+00 0.00E+00 l

ZN-65 CURIES 0.00E+00 8.2EE-06 0.00E+00 0.00E+00 SR-90 CURIES 6.44E-06 2.78E-07 0.00E+00 0.00E+00 CS-137 CURIES 1.70E-06 0.00E+00 0.00E+00 0.00E+00

)

TOTAL FOR PERIOD l

CURIES l 2.42E-03 l 1.59E-03 l 0.00E+00 l 0.00E+00 ll 1

G-ALPHA CURIES 5.42E-07 3.94E-07 0.00E+00 0.00E+00 i

H-3 CURIES 4.24E+00 4.36E+00 0.00E+00 0.00E+00

................................................................................i

{~

4 f,

  1. 4 1

i TABLE 2-3B*

~

E.

I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT *1996 I

Gaseous Effluents-Ground Level Releases 1

Unit: 2 j

Starting :

1-Jul-1996 Ending : 31-Dec-1996 l

CONTINUOUS MODE-l BATCH MODE **

ll N'.CLIDES RELEASED l

UNIT l QUARTER 3 l QUARTER 4 l QUARTER 3 l QUARTER 4-l l j

Zeroes in this table indicate that no radioactivity was present at detectable levels.

See Table 2-7 for typical minimum detectable concentrations.

There are no batch mode radioactive gaseous release pathways at Plant Hatch.

(~

I I

i 4

l i

i i

_.~

i m

  • ABLE 2-3C*

~

E. I. HATCH NUCLEAR PLANT j

ANNUAL RADIOACTIVE EFFLUP.NT RELEASE REPORT *1996 Gaseous Effluents-Ground Level Releases d

Unit: Site Starting :

1.Jan-1996 Ending : 30-Jun-1996 4

l CONTINUOUS MODE l

BATCH MODE **

l l

NUCLIDES RELEASED l

UNIT l QUARTER 1 l QUARTER 2 l QUARTER 1 l QUARTER 2 l i

a FISSION GASES f

XE-135M CURIES 5.95E-01 0.00E+00 0.00E+00 0.00E+00 KR-87 CURIES 0.00E+00 3.52E-02 0.00E+00 0.00E+00 KR-85M CURIES 0.00E+00 6.75E-03 0.00E+00 0.00E+00 XE-135 CURIES 4.11E+01 2.05E+01 0.00E+00 0.00E+00 3

XE-133 CURIES 1.24E+01 3.34E+00 0.00E+00 0.00E+00

}

TOTAL FOR PERIOD l

CURIES l 5.40E+01 l 2.38E+01 j 0.00E+00 l 0.00E+00 l' j

IODINES I-135 CURIES 1.72E-03 0.00E+00 0.00E+00 0.00E+00 I-133 CURIES 8.69E-02 6.06E-02 0.00E+00 0.00E+00 I-131 CURIES 4.60E-03 2.57E-03 0.00E+00 0.00E+00 I

TOTAL FOR PERIOD l

CURIES l 9.32E-02 l 6.32E-02 l 0.00E+00 l 0.00E+00 l

)

PARTICULATES j

I-131 CURIES 3.81E-04 1.83E-04 0.00E+00 0.00E+00 BA-140 CURIES 7.87E-04 4.05E-04 0.00E+00 0.00E+00 CR-51 CURIES 0.00E+00 6.82E-06 0.00E+00 0.00E+00 CE-141 CURIES 4.24E-05 1.10E-05 0.00E+00 0.00E+00 RU-103 CURIES 8.19E-06 1.21E-05 0.00E+00 0.00E+00 1

SR-89 CURIES 3.51E-04 3.35E-02 0.00E+00 0.00E+00 ZN-65 CURIES 2.35E-06 3.96E-06 0.00E+00 0.00E+00 MN-54 CURIES 0.00E+00 1.39E-06 0.00E+00 0.00E+00 CO-60 CURIES 0.00E+00 1.62E-06 0.00E+00 0.00E+00 SR-90 CURIES 6.37E-06 2.25E-04 0.00E+00 0.00E+00 CS-137 CURIES 1.96E-08 0.00E+00 0.00E+00 0.00E+00 2

TOTAL FOR PERIOD l

CURIES l 1.58E-03 l 3.44E-02 l 0.00E+00 l 0.00E+00 l 4

}

G-ALPHA CURIES 9.99E-07 6.25E-07 0.00E+00 0.00E+00 j

H-3 CURIES 4.00E+00 3.77E+00 0.00E+00 0.00E+00

?

i

_.. ~..

i L

I 1

i

)

l TABLE 2-3C*

l E. I. HATCH NUCLEAR PLANT

~

l ANNUAL PADIOACTIVE EFFLUENT RELEASE REPORT.* 1996 1

l Gaseous Effluents-Ground Level Releases l

l Unit: Site Starting :

1-Jan-1996 Ending : 30.Jun 1996 l

l l

CONTINUOUS MODE l

BATCH MODE **

l NUCLIDES RELEASED l

UNIT l QUARTER 1 l QUARTER 2 l QUARTER 1 i

Zeroes in this table indicate that no radioactivity was present at detectable levels.

See Table 2-7 for typical minimum detectable concentrations.

C*

There are no batch mode radioactive gaseous release pathways at Plant Hatch.

k j

1 5

i l

l l

. t i

I i

i I

l i

/T

)

(

1 V

TABLE 2-3C*

E.

I. HATCH NUCLEAR PLANT i

ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT ' 1996 Gaseous Effluents-Ground Level Releases Unit: Site Starting :

1-Jul-1996 Ending : 31-Dec-1996 l

CONTINUOUS MODE l

BATCH MODE **

l j

................................................................................ I NUCLIDES RELEASED l

UNIT l QUARTER 3 l QUARTER 4 l QUARTER 3 l QUARTER 4 l FISSION GASES 4

XE-135M CURIES 1.62E+01 1.29E+01 0.00E+00 0.00E+00 XE-135 CURIES 2.19E+01 4.35E+01 0.00E+00 0.00E+00 XE-133 CURIES 7.00E+01 1.08E+01 0.00E+00 0.00E+00 TOTAL FOR PERIOD l

CURIES l 1.08E+02 l 6.71E+01 l 0.00E+00 l 0.00E+00 l IODINES

/"'

I-132 CURIES 1.49E-03 0.00E+00 0.00E+00 0.00E+00 j

t\\_,

I-135 CURIES 8.22E-04 0.00E+00 0.00E+00 0.00E+00 I-133 CURIES 9.44E-02 1.18E-01 0.00E+00 0.00E+00 I-131 CURIES 3.91E-03 5.13E-03 0.00E+00 0.00E+00 TOTAL FOR PERIOD l

CURIES l 1.01E-01 l 1.23E-01 l 0.00E+00 l 0.00E+00 l PARTICULATES I-131 CURIES 2.57E-04 5.04E-04 0.00E+00 0.00E+00 BA-140 CURIES 7.76E-04 1.08E-03 0.00E+00 0.00E+00 CR-51 CURIES 0.00E+00 2.44E-05 0.00E+00 0.00E+00 CE-141 CURIES 4.33E-05 1.26E-05 0.00E+00 0.00E+00 NB-95 CURIES 1.29E-06 0.00E+00 0.00E+00 0.00E+00 SR-89 CURIES 1.41E-03 5.64E-04 0.00E+00 0.00E+00 CO-58 CURIES 2.36E-06 1.23E-06 0.00E+00 0.00E+00 ZN-65 CURIES 1.77E-05 1.85E-05 0.00E+00 0.00E+00 MN-54 CURIES 1.05E-06 0.00E+00 0.00E+00 0.00E+00 CO-60 CURIES 1.08E-05 6.94E-07 0.00E+00 0.00E+00 SR-90 CURIES 6.70E-06 2.45E-06 0.00E+00 0.00E+00 CS-137 CURIES 3.86E-06 0.00E+00 0.00E+00 0.00E+00 TOTAL FOR PERIOD l

CURIES l 2.53E-03 l 2.21E-03 l 0.00E+00 l 0.00E+00 l

\\

/

H-3 CURIES 5.79E+00 5.39E+00 0.00E+00 0.00E+00

(_-)

l l i

I

4 r

AU TABLE 2-3C*

E.

I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT.' 1996 Gaseous Effluents-Ground Level Releases Unit: Site Starting :

1-Jul-1996 Ending : 31-Dec-1996 1

l CONTINUOUS MODE l

BATCH MODE **

l

.NUCLIDES RELEASED l

UNIT l QUARTER 3 jQUARTER 4 l QUARTER 3 l QUARTER 4 l

.............................p..................................................

i i

4 Zeroes in this table indicate that no radioactivity was present at detectable levels.

See Table 2-7 for typical minimum j

detectable concentrations.

There are no batch mode radioactive gaseous release pathways at Plant Hatch.

A*

1 a

u.J _ _

i V

TABLE 2-4A 1

E. I. HATCH NUCLEAR PLANT i

I ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 1996 AIR DOSES DUE TO GASEOUS RELEASES Unit: 1 Starting: 01-Jan-1996 Ending: 30-Jun-1996 i,

t

)

Cumulative Doses per Quarter Type Tech Units Quarter

% of Quarter

% of 1

of Spec 1

Tech 2

Tech j

Radi-Limit Spec Spec ation Limit Limit i

Gamma 5.0 mrad 1.75E-02 3.50E-01 7.83E-03 1.57E-01 Beta 10.0 mrad 2.39E-02 2.39E-01 1.12E-02 1.12E-01 i

i I

1 j

Cumulative Doses per Year Type Tech Units Year to

% of of Spec Ending Tech Radi-Limit Date Spec j

ation Limit i

Gamma 10.0 mrad 2.53E-02 2.53E-01 i

Beta 20.0 mrad 3.51E-02 1.76E-01

)

I 1

4 k

2 a

i i

i m

(

TABLE 2 4A E.

I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 1996 AIR DOSES DUE TO GASEOUS RELEASES j

Unit: 1 i

Starting: 01-Jul-1996 Ending: 31-Dec-1996 Cumulative Doses per Quarter Type Tech Units Quarter

% of Quarter

% of of Spec 3

Tech 4

Tech Radi-Limit Spec Spec ation Limit Limit Gamma 5.0 mrad 2.98E-02 5.95E-01 3.53E-02 7.07E-01 Beta 10.0 mrad 2.30E.02 2.30E-01 3.62E-02 3.62E-01 Cumulative Doses per Year i

l Type.

Tech Units Year to

% of l

of Spec Ending Tech l

Radi-Limit Date Spec ation Limit i

l Gamma 10.0 mrad 9.04E-02 9.04E-01

)

I Beta 20.0 mrad 9.43E-02 4.71E-01 J

l l

^

1

)

I l

1 1

F d

]

i k

4 s

l

. i

...-..-.... - -. ~..... -.

i L

i a

i TABLE 2-4B i

E.

I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 1996 AIR DOSES DUE TO GASEOUS RELEASES Unit: 2 Starting: 01-Jan-1996 Ending: 30-Jun-1996 Cumulative Doses per Quarter

)

Type Tech Units Quarter

% of Quarter

% of of Spec 1

Tech 2

Tech Radi-Limit Spec Spec ation Limit LLait Gamma 5.0 mrad 1.30E-02 2.60E-01 9.57E-03 1.91E-01 Beta 10.0 mrad 1.62E-02 1.62E-01 1.29E-02 1.29E-01 Cumulative Doses per Year Type Tech Units Year to

% of of Spec Ending Tech

[,'

Radi-Limit Date Spec ation Limit Gamma 10.0 mrad 2.26E-02 2.26E-01 Beta 20.0 mrad 2.91E-02 1.46E-01 1

_. _ _ _. = _ _

J t

1 i

TABLE 2-4B e

E. I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 1996 l

AIR DOSES DUE TO GASEOUS RELEASES Unit: 2 Starting: 01-Jul-1996 Ending: 31-Dec-1996 4

l

'I Cumulative Doses per Quarter a

4 Type Tech Units Quarter

% of Quarter

% of of Spec 3

Tech 4

Tech Radi-Limit Spec Spec ation Limit Limit Beta 10.0 mrad 2.50E-02 2.50E-01 1.22E-02 1.22E-01 i

l Cumulative Doses per Year Type Tech Units Year to

% of of Spec Ending Tech Radi-Limit Date Spec 4

ation Limit 1

Gamma 10.0 mrad 4.18E-02 4.18E-01 Beta 20.0 mrad 6.63E-02 3.32E-01 j

i 1

h.

i, 4

1-1 4

4

l TABLE 2-5A E. I. HATCH-NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 1996 DOSES TO A MEMBER OF THE PUBLIC DUE TO RADIOIODINES, TRITIUM, AND PARTICULATES IN GASEOUS RELEASES Unit: 1 Starting: 01-Jan-1996 Ending: 30-Jun-1996 1

Cumulative Doses per Quarter Organ Tech Unit Quarter

% of Quarter

% of.

i Spec 1

Tech 2

Tech Limit Spec Spec Limit Limit Bone 7.5 mrem 1.04E-03 1.38E-02 2.13E-04 2.84E-03 Liver 7.5 mrem 5.07E-04 6.75E-03 5.33E-04 7.11E-03 TBody 7.5 mrem 5.80E-04 7.74E-03 4.88E-04 6.51E-03 Thyroid 7.5 mrem 1.88E-02 2.51E-01 2.10E-02 2.80E-01 i

Kidney 7.5 mrem 5.43E-04 7.25E-03 5.73E-04 7.65E-03 Lung 7.5 mrem 4.42E-04 5.90E-03 4.57E-04 6.10E-03 GILLI 7.5 mrem 4.83E-04 6.44E-03 4.86E-04 6.48E.03 j

l Cumulative Doses per Year Organ Tech Units Year to

% of Spec Ending Tech Limit Date Spec Limit i

Bone 15.0 mrem 1.25E-03 8.33E-03 j

Liver 15.0 mrem 1.04E-03 6.93E-03 TBody 15.0 mrem 1.07E-03 7.12E-03 l

Thyroid 15.0 mrem 3.98E-02 2.65E-01 i

Kidney 15.0 mrem 1.12E-03 7.45E-03 Lung 15.0 mrem 9.00E-04 6.00E-03 GILLI 15.0 mrem 9.69E-04 6.46E-03 l

l 1

1 s

%s 4 -

-.. - -... -,_..-_ ~_ = = -

4

/n t

t TABLE 2-5A E.

I.

HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 1996 DOSES TO A MEMBER OF THE PUBLIC DUE TO RADIOIODINES, TRITIUM, AND PARTICULATES IN GASEOUS RELEASES Unit: 1 Starting: 01-Jul-1996 Ending: 31-Dec-1996 i

Cumulative Doses per Quarter Organ Tech Unit Quarter

% of Quarter

% of Spec 3

Tech 4

Tech l

Limit Spec Spec Limit Limit Bone 7.5 mrem 2.18E-03 2.90E-02 8.64E-03 1.15E-01 i

Liver 7.5 mrem 1.01E-03 1.35E-02 7.08E-04 9.45E-03 l

TBody 7.5 mrem 1.03E-03 1.37E-02 1.21E-03 1.61E-02 Thyroid 7.5 mrem 1.70E-02 2.26E-01 2.62E-02 3.49E-01 Kidney 7.5 mrem 1.03E-03 1.37E-02 7.57E-04 1.01E-02 Lung 7.5 mrem 9.51E-04 1.27E-02 7.27E-04 9.69E-03 GILLI 7.5 mrem 1.04E-03 1.39E-02 9.50E-04 1.27E-02 1

$s\\

Cumulative Doses per Year Organ Tech Units Year to

% of Spec Ending Tech Limit Dace Spec Limit l

Bone 15.0 mrem 1.21E-02 8.05E-02 Liver 15.0 mrem 2.76E-03 1.84E-02 4

TBody 15.0 mrem 3.31E-03 2.21E-02 Thyroid 15.0 mrem 8.29E-02 5.53E-01 1

Kidney 15.0 mrem 2.90E-03 1.93E-02 Lung 15.0 mrem 2.58E-03 1.72E-02 GILLI 15.0 mrem 2.96E-03 1.98E-02 i

2 ii G*

1 4

i l

l TABLE 2-5B E. I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 1996 DOSES TO A MEMBER OF THE PUBLIC DUE TO RADIOIODINES, TRITIUM, AND PARTICULATES IN GASEOUS RELEASES Unit: 2 Starting: 01-Jan-1996 Ending: 30-Jun-1996 Cumulative Doses per Quarter Organ Tech Unit Quarter

% of Quarter

% of Spec 1

Tech 2

Tech Limit Spec Spec Limit Limit Bone 7.5 mrem 7.44E-03 9.92E-02 4.19E-01 5.58E+00 i

Liver 7.5 mrem 2.27E-03 3.03E-02 1.98E-03 2.64E-02 j

TBody 7.5 mrem 2.79E-03 3.71E-02 3.13E-02 4.18E-01 Thyroid 7.5 mrem 1.31E-01 1.75E+00 8.60E-02 1.15E+00 Kidney 7.5 mrem 2.60E-03 3.47E-02 2.20E-03 2.93E-02

~

Lung 7.5 mrem 1.98E-03 2.64E-02 9.32E-03 1.24E-01 GILLI 7.5 mrem 2.12E-03 2.82E-02 1.64E-02 2.18E-01 Cumulative Doses per Year s

Organ Tech Units Year to

% of Spec Ending Tech Limit Date Spec Limit Bone 15.0 mrem 4.26E-01 2.84E+00 Liver 15.0 mrem 4.26E-03 2.84E-02 TBody 15.0 mrem 3.41E-02 2.28E-01 Thyroid 15.0 mrem 2.17E-01 1.45E+00 Kidney 15.0 mrem 4.80E-03 3.20E-02 Lung 15.0 mrem 1.13E-02 7.54E-02 GILLI-15.0 mrem 1.85E-02 1.23E-01 1

I

('

\\

^

(_

TABLE 2-5B E.

I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 1996 DOSES TO A MEMBER OF THE PUBLIC DUE TO RADIOIODINES, TRITIUM, AND PARTICULATES IN GASEOUS RELEASES

-Unit: 2 Starting: 01-Jul-1996 Ending: 31-Dec-1996 i

-i Cumulative Doses per Quarter Organ Tech Unit Quarter t of Quarter

% of Spec 3

Tech 4

Tech Limit Spec Spec Limit Limit Bone 7.5 urem 1.86E-02 2.48E-01 3.40E-03 4.53E-02 Liver 7.5 mrem 2.81E-03 3.75E-02 2.96E-03 3.95E-02 TBody 7.5 mrem 3.55E-03 4.73E-02 2.90E-03 3.87E-02 Thyroid 7.5 mrem 1.16E-01 1.55E+00 1.37E-01 1.82E+00 Kidney 7.5 mrem 3.10E-03 4.13E-02 3.31E-03 4.41E-02 Lung 7.5 mrem 2.77E-03 3.69E-02 2.59E-03 3.46E-02 GILLI 7.5 mrem 3.16E 4.21E-02 2.69E-03 3.59E-02

..................................-03

\\s /

Cwmulative Doses per Year s

Organ Tech Units Year to

% of Spec Ending Tech

}

Limit Date Spec 3

Limit j

Bone 15.0 mrem 4.48E-01 2.99E+00 Liver 15.0 mrem 1.00E-02 6.69E-02 TBody 15.0 mrem 4.06E-02 2.71E-01

)

Thyroid 15.0 mrem 4.70E-01 3.14E+00 Kidney 15.0 mrem 1.12E-02 7.47E-02 Lung 15.0 mram 1.67E-02 1.11E-01 GILLI 15.0 mrem 2.43E-02 1.62E-01 a

I -

e i !

4

1 (N

TABLE 2-7 MINIMUM DETECTABLE CONCENTRATIONS - GASEOUS SAMPLE ANALYSES E. I. HATCH NUCLEAR PLANT JANUARY,1996 THROUGH DECEMBER,1996 The values in this table represent a pn'ori Minimum Detectable Concentration (MDC) which are typically achievedin laboratory analyses of gaseous radwaste samples.

RADIONUCLIDE MDC UNITS Kr-87

- 2.94E-08 uCi/cc Kr-88 3.22E-08 uCi/cc Xe-133 2.30E-08 uCi/cc Xe-133m 7.30E-08 uCi/cc Xe-135 8.73E-09 uCi/cc pV Xe-138 1.99E-07 uCi/cc l-131 1.34E-13*

uCi/cc l-133 1.53E-13*

uCi/cc Mn-54 1.62E-13*

uCi /cc Fe-59 3.42E-13*

uCi/cc Co-58 1.30E-13*

uCi/cc Co-60 1.54E-13*

uCi/cc Zn-65 2.54E-13*

uCi/cc Mo-99 9.61 E-13*

uCi/cc Cs-134 1.42E-13*

uCi/cc Cs-137 1.28E-13*

uCi/cc Ce-141 1.26E-13*

uCi/cc Ce-144 5.64E-13*

uCi/cc Sr-89 1.10E-16 uCi/cc Sr-90 6.70E-16 uCi/cc H-3 4.00E-07 uCi/cc

  • Based on an estimated sample quantity of 4.078E+07 cc's.

f l

3.0 Solid Weste 3.1 Regulatory Limits /ODCM The ODCM Limits presented in this section are for Unit 1 and Unit 2 and are 1

stated in part.

3.1.1 Solid Radioactive Waste System A.3.1 Solid Radioactive Waste System control states:

The solid radwaste system shall be used in accordance with the PROCESS CONTROL PROGRAM to provide for the SOLIDIFICATION of wet solid wastes I

and for the SOLIDIFICATION and packaging of other radioactive wastes, as l

required, to ensure that they meet requirements of 10 CFR Parts 20 and 71, prior to shipment of radioactive wastes from the site.

l i

y 3.1.2 Reporting Requirements i

Technical Specification 5.6.3 The Radioactive Effluent Release Report covering the operation of the unit shall be submitted in accordance with 10 CFR 50.36a. The repod shall include a summary of the quantities of radioactive liquid and gaseous effluents and solid waste released from the unit. The material provided shall be consistent with the objectives outlined in the ODCM and the Process Control Program and in conformance with 10 CFR 50.36a and 10 CFR 50, Appendix 1,Section IV.B.1.

l 3.1.3 Process Control Program (PCP)

A.4.1 states in part:

The Radioactive Effluent Release Report, submitted in accordance with Technical Specification 5.6.3, shall include a summary of the quantities of solid radwaste l

released from the units as outlined in Regulatory Guide 1.21, " Measuring, Evaluating, and Reporting Radioactivity in Solid Wastes and Releases of i

Radioactive Materials in Liquid and Gaseous Effluents from Light-Water-Cooled Nuclear Power Plants," Revision 1, June 1974, with data summarized on a 6 month basis following the format of Appendix B thereof.

O 1,

,~

I O

For each type of solid radwaste shipped offsite during the report period, the report shall include the following information:

1

a. Container volume.
b. Total curie quantity (specify whether determined by measurement of f

estimate).

c. Principal radionuclides (specify whether determined by measurement or estimate).

j

d. Type of waste (such as spent resin, compacted dry waste, evaporator bottoms).
e. Type of container (such as LSA, type A, type B, large quantity).

1

f. Solidification agent (such as cement).

1 Major changes to the solid radioactive waste treatment system shall be reported j

to the Nuclear Regulatory Commission in the Radioactive Effluent Release Report i

for the period in which the evaluation was reviewed and accepted by the PRB.

OO 3.2 Solid Waste Data Regulatory Guide 1.21, Table 3 is found in this report as Table 3-1 A and 3-1B.

O

. ~ _ _ _ _ _ __.

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT 1996

(

JANUARY 1,1996 - DECEMBER 31,1996 i

\\-

SOLID WASTE AND lRRADIATED FUEL SHIPMENTS FOR UNITS I AND 11 TABLE 3-IA FORM TITLE: REG GUIDE 1.21 EFF: UE2C AND WASTE DISPOSAL ANNUAL REPORT OF SOLID WASTE AND IRRADIATED FUEL SHIPMENTS PERIOD COVERED: FROM i/ 1 /9f

'"O 6 /10 /9E FOR IJNIT 1,42 A. SOLID WASTE SHIPPED OFFSITI FOR BURIAL OR DISPOSAL (Not irradiated fuel)

1. Type of waste UNIT 6 Month Est. Total Period ERROR t T.~ Spent resins, filter sludges, evaporator m'

1.20E2 10 bottoms, etc.

C1 1.84E3 E

b. Dry compressible waste, contaminated equip.

m' 3.39El 20 etc.

etc.

C1 1.07E0 E

c. Irradiated components, control r:ds, m'

E C1 E

E

d. Control Rod Drive Filters m'

E C1 E

E j

e. Other (describe) m' E

equip. etc.

C1 E

E 2.

Estimate of major nuclide composition (by type of waste) i ISOTOPE PERCENT CURIES a.ZN-65 47.54 874.81 FE-55 12.96 236.44 CO-60 15.83 291.27 CS-137 2.43 44.79 OTHER 21.23 390.64 b.ZN-65 31.49

.337 FE-55 34.39

.368 CO-60 10.37

.111 CS-137

.28

.003 OTHER 23.67

.264 c.

i d.

e.

3.

Solid Waste Disposition.

Mu=her ef C hi men t e Mode ef Tranannetarinn Baneinatinn 27 TRUCK BARNWELL B.

IRRADIATED FUEL SHIPMENTS (Disposition)

[

Number of th 4 mant a New4m ef Trananortation neatsnarian w

N/A N/A N/A

)

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT 1996 e

l JANUARY 1,1996 - DECEMBER 31,1996 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS i

FOR UNITS l AND ll l

TABLE 3-IA (Cont'd)

FORM TITLE: REG GUIDE 1.21 EFFLUENT AND, WASTE DISPOSAL ANNUAL REPORT OF SOLID WASTE AND IRRADIATED FUEL SHIPMENTS i

i PERIOD COVERED:

> ROM ~7/ 1 /es TO 12/11 /es FOR UNIT:1,./2 i

l A. SOLID WASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL (Not irradiated fuel) l

1. Type of waste IRtIT 6 Month Est. Total l

Period EREOR %

i

a. Spent resins, filter sludges, evaporator m'

6.292E1 10 bottoms, etc.

Ci 1.2168E2 E

l

b. Dry compressible waste, contaminated equip.

m' 6.364E1 20 i

etc.

C1 3.497E0 E

l

c. Irradiated components, control rods, m'

1.839El 20 C1 1.19752E5 E

d. Control Rod Drive Filters m'

E Ci E

E

e. Other (descrikt) m' E

equip. etc.

C1 E

E O

2.

Estimate of major nuclide compos'. tion (by type of waste)

ISOTOPE PERCENT Crfstaa a.ZN-65 18.53 22.544 FE-55 12.3 14.965 CO-60 44.42 54.046 CS-137 6.07 7.391 OTliER 18.68 22.734 b.ZN-65 31.74 1.110 FE-55 34.6 1.210 CO-60 10.29

.360 CS-137

.26

.009 OTHER 23.11

.308 c.CR-51

.395 473

~

NI-63 1.867 2235.88 MN-54 2.831 3389.91 FE-55 48.914 58575.79 CO-60 36.604 43834.09 OTHER P.389 11243.33 3.

Solid Waste Disposition Nusnhar of Chinmanen Mew 4m of Tranamnet2tinn Destination 27 TRUCK EARNNELL O

B.

IRRADIATED FDEL SHIPMENTS (Disposition)

Numher of Chinsmanen Mew 4m of Tranennetatinn Destination NA NA NA EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT 1996 i {-

JANUARY 1,1996 - DECEMBER 31,1996

)

SOLID WASTE AND IRRADIATED FUEL SHIPMENTS FOR UNITS I AND 11 i

TABLE 3-IB l

FORM TITLE:

OFFSITE DOSE CALCULATION MANUAL, SECTION 7.2, REPORT PERIOD COVERED FROM:

i/ 1 /96 TO:

6 /30 /96 FOR UNIT:

1 /2 TYPE CURIE PRMCFLE SURIAL NUGABER OF YOLutIE TYPE SOLEMFICATION OF QUANTITYr NUCLIDESI CONTAMER CONTAMERS OF EACH SHPGAENTl AGENT WASTE DETERRAMED DETERetMATION DESCRFTION SHIPPED CONTAINER CONTAMER CUSIC FEET (FT 3) i DewATERED 1586.4 Zn65, Fe 55, MGH 6

132.4 TYPES MA RESM Co 60, Cs 137 WTEGRfTY CASK i

enEASURED CO9(TAINER 10-142 O

f DewATERED 250.3 Zn65,Fe55, HIGH 16 202.1 WPE A MA RESIN Co 60, Cs 137 WTEGRITY CASK i

RAEASURED CONTAMER 14-210 TORUS 4.06 zn65, F 55, seGH 1

202.1 TYPE A MA Co 60, Cs 137 INTEGRTTY CASK FILTERS ASEASURED CONTAINER 14-210 daw 1.07 Zn65, Fe 55, STRONG 13 92*

STRONG (DRY ACTIVE Co 60, Cs 137 TIGHT TIGHT MA WASTE)

ESTit4ATED CONTAMER SOXES RAATED 8 25 6 25

  • Size of container and number of shipments, varies due to using different waste processors.

O 1

I i

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT 1996 JANUARY 1,1996 - DECEMBER 31,1996 l

SOLID WASTE AND IRRADIATED FUEL SHIPMENTS j

FOR UNITS I AND ll I

TABLE 3-IB (Cont'd) i

)

i i

1 l

FORM TITLE:

. SECTION 7.2, REPORT

[

OFFSITE DOSE CALCUIATION MANUAL, PERIOD COVERED FROM:

'7

/1

/9E

'[O : 12/11/98 FoR UNIT: 1 /, 1 i

ma coax.

mzu.

==

l OF OGhWFITT/

ure mme/

cm N

EM N/

M unesis asT======

mamnow mascarrrzas assyren ensumanum casuh3 REEL 1

ausse esse trT 31 l

..m a na z.

    • 8K i

ne wismo so.2 re ss. ana na easar j

    • S=8 11 202.1 waw N

i i

81M1818 DAW Emes. Ce 00 re es, un es um W

M4 N

3.5 Acme comassa 25 92 somes O

wasten ses. ric _.

(.,)

serzuhTso "as. r"."a"s 8"un 7

IIs4 MDurED 119370 8

un c

u ses m aowane c.ee maowme wwwmtso 33 o,et. r. as seen mesa,com umam 2

128 maowme i

  • Actual number of containers are unknown due to the vanous sizes used by the offsite wne processors

" Actual volume of containers are unknown due to the various sizes used by the offsite waste processors.

O -

f 4.0 Changes to the ODCM i

Pursuant to Technical Specification 5.5.1 and ODCM section 7.2.2.5 Licensee initiated changes shall be submitted to the NRC in the form of a complete, legible copy of the entire ODCM as part of or concurrent with the Radioactive Effluent Release Report for the period of the report in which any change in the ODCM was made. Each change shall be identified by markings in the margin of the affected pages, clearly indicating the area of the page that was changed, and shall indicate the date (i.e., month and year) the change was implemented.

On December 19,1996, the PRB recommended approval of changes to the ODCM Chapter 4, Radiological Environmental Monitoring Program.

Appendix B of this report contains the revised ODCM. The modifications are identified as Revision 11.

5.0 Doses to Members of the Public inside the Site Boundary The Radioactive Effluent Release Report shall also include an assessment of the radiation doses from radioactive liquid and gaseous effluents to MEMBERS OF THE PUBLIC due to their activities inside the SITE BOUNDARY during the report O

period; this assessment must be performed in accordance with the ODCM.

The locations of concem within the site boundary are the Roadside Park, the Camping Area, the Recreation Area, and the Visitors Center. Listed in Table 4-1 are: The distance and direction from a point midway between the center of Unit 1 and the Unit 2 reactors, the dispersion and deposition factors for any releases from the Main Stack (elevated)and from the reactor building (ground 5

level); and the estimated maximum occupancy factor for an individual and the assumed age group of this individual.

The source term is not listed in Table 4-1. The source term is listed in Tables 2-2A and 2-2B, for the elevated releases. Similarly, it is listed in Tables 2-3A and 2-3B for the ground level releases.

The maximum doses in units of mrem accumulated by an individual MEMBER OF THE PUBLIC due to their activities inside the site boundary during the reporting period are presented in Table 4-1.

O l

(]N

\\u, TABLE 4-1 E.

I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 1996 DOSE TO A MEMBER OF THE PUBLIC 3

DUE TO ACTIVITIES INSIDE THE SITE BOUNDARY I

Unit: Site Starting: 01-Jan-1996 Ending: 30-Jun-1996 Page:

1 Location Name ROADSIDE PARK Distance (kilometers) 1.18E+00 i

Sector WNW Occupancy Factor 2.28E-04 (2.00E+00 hr/yr)

Age Group CHILD i

Ground Level Releases:

Noble Gas X/Q (sec/m3) 7.83E-06 Particulate X/Q (sec/m3) 7.00E-06 Particulate D/Q (m-2) 2.01E-08 Mixed Mode Releases:

Noble Gas X/Q (sec/m3)

N/A Particulate X/Q (sec/m3)

N/A N

Particulate D/Q (m-2)

N/A Elevated Releases:

Noble Gas X/Q (sec/m3) 2.42E-08 Particulate X/Q (sec/m3) 2.37E-08

)

Particulate D/Q (m-2) 1.29E-09 1

Units Quarter 1 Quarter 2 Quarters Year to 1 and 2 Ending i

Date Bone mrem 6.78E-06 5.89E-06 1.27E-05 1.27E-05 Liver mrem 6.98E-06 3.90E-06 1.09E-05' 1.09E-05 TBody mrem 6.92E-06 3.96E-06 1.09E-05 1.09E-05 Thyroid mrem 2.81E-05 1.81E-05 4.63E-05 4.63E-05 Kidney mrem 7.05E-06 3.95E-06 1.10E-05 1.10E-05 i

Lung mrem 6.99E-06 7.80E-06 1.48E-05 1.48E-05 GI-LLI mrem 6.91E-06 4.14E-06 1.10E-05 1.10E-05 l

l 1 i i

O TABLE 4-1 E. I. HATCH NUCLEAR PLANT l

ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 1996 DOSE TO A MEMBER OF THE PUBLIC i

i l

DUE TO ACTIVITIES INSIDE THE SITE BOUNDARY l

l' Unit: Site l

Starting: 01-Jan-1996

'Ending: 30-Jun-1996 t-Page:

2 i

Location'Name CAMPING AREA l

Distance (kilometers) 1.27E+00 i

Sector.

WNW

[

Occupancy Factor 5.48E-03 (4.80E+01 hr/yr)

Age Group-CHILD j

Ground Level Releases:

Noble Gas X/Q (sec/m3) 7.03E-06 Particulate X/Q (sec/m3) 6.27E-06 Particulate D/Q (m-2) 1.80E-08 Mixed Mode Releases:

Noble Gas X/Q (sec/m3)

N/A Particulate X/Q (sec/m3)

N/A Particulate D/Q (m-2)

N/A Elevated Releases:

Noble Gas X/Q (sec/m3) 2.38E-08 Particulate X/Q (sec/m3) 2.33E-08 Particulate D/Q (m-2) 1.21E-09 Units Quarter 1 Quarter 2 Quarters Year to 1 and 2 Ending Date Bone mrem 1.48E-04 1.28E-04 2.76E-04 2.76E-04 i

Liver mrem 1.52E-04 8.53E-05 2.37E-04 2.37E-04 TBody mrem 1.51E-04 8.67E-05 2.37E-04 2.37E-04 Thyroid mrem 6.08E-04 3.92E-04 1.00E-03 1.00E-03 Kidney mrem 1.53E-04 8.63E-05 2.40E-04 2.40E-04 Lung mrem 1.52E-04 1.69E-04 3.21E-04 3.21E-04 GI-LLI mrem 1.50E-04 9.06E-05 2.418-04 2.41E-04 i

1 I

l

1 i

/~'N

'(b) 1 TABLE 4-1 E. I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 1996 DOSE TO A MEMBER OF THE PUBLIC DUE TO ACTIVITIES INSIDE THE SITE BOUNDARY Unit: Site Starting: 01-Jan-1996 Ending: 30-Jun-1996 l

Page:

3 Location Name RECREATION AREA Distance (kilometers) 1.03E+00 l

l Sector SSE l

Occupancy Factor 2.37E-02 (2.08E+02 hr/yr) 1 Age Group CHILD t

Ground Level Releases:

Noble Gas X/Q (sec/m3) 6.42E-06 Particulate X/Q (sec/m3) 5.73E-06 1

Particulate D/Q (m-2) 2.36E-08 Mixed Mode Releases:

Noble Gas X/Q (sec/m3)

N/A Particulate X/Q (sec/m3)

N/A A

Particulate D/Q (m-2)

N/A 4

Elevated Releases:

Noble Gas X/Q (sec/m3) 3.30E-08 Particulate'X/Q (sec/m3) 3.21E-08 j

Particulate D/Q (m-2) 1.56E-09 i

j Units Quarter 1 Quarter 2 Quarters Year to l

1 and 2 Ending i

Date Bone mrem 5.88E-04 5.11E-04 1.10E-03 1.10E-03 Liver mrem 6.06E-04 3.41E-04 9.47E-04 9.47E-04 TBody mrem 6.00E-04 3.47E-04 9.47E-04 9.47E-04 Thyroid mrem 2.41E-03 1.56E-03 3.97E-03 3.97E-03 Kidney mrem 6.11E-04 3.45E-04 9.57E-04 9.57E-04 Lung mrem 6.07E-04 6.73E-04 1.28E-03 1.28E-03 GI-LLI mrem 5.99E-04 3.62E-04 9.62E-04 9.62E-04 4

a

[.

l l

l

/**g TABLE 4-1 E.

I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 1996 DOSE TO A MEMBER OF THE PUBLIC DUE TO ACTIVITIES INSIDE THE SITE BOUNDARY Unit: Site Starting: 01-Jan-1996 Ending: 30-Jun-1996 Page:

4 Location Name VISITORS CENTER Distance (kilometers) 6.94E-01 Sector WSW i

Occupancy Factor 4.57E-04 (4.00E+00 hr/yr) i Age Group CHILD l

Ground Level Releases:

Noble Gas X/Q (sec/m3) 1.87E-05 i

Particulate X/Q isec/m3) 1.72E-05 Particulate D/Q (m-2) 5.47E-08 l

Mixed Mode Releases:

Noble Gas X/Q (sec/m3)

N/A Particulate X/Q (sec/nG)

N/A i (s Particulate D/Q (m-2)

N/A

(,

Elevated Releases:

l Noble Gas X/Q (sec/m3) 5.00E-08 Particulate X/Q (sec/nG) 4.97E-08 Particulate D/Q (m-2) 2.26E-09 I

Units Quarter 1 Quarter 2 Quarters Year to 1 and 2 Ending Date Bone mrem 3.02E-05 2.67E-05 5.69E-05 5.69E-05 i

Liver mrem 3.12E-05 1.69E-05 4.80E-05 4.80E-05 TBody mrem 3.09E-05 1.72E-05 4.81E-05 4.81E-05 i

Thyroid mrem 1.35E-04 8.69E-05 2.22E-04 2.22E-04 j

Kidney mrem 3.15E-05 1.71E-05 4.86E-05 4.86E-05

~

Lung mrem 3.13E-05 3.61E-05 6.73E-05 6.73E-05 j

GI-LLI mrem 3.08E-05 1.81E-05 4.89E-05 4.89E-05 3

t

. ~.

.... - - -.. -~

4 T

O TABLE 4-1 E. I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE' EFFLUENT RELEASE REPORT - 1996 DOSE TO A MEMBER OF THE PUBLIC DUE TO ACTIVITIES INSIDE THE SITE BOUNDARY l

Unit: Site i

Starting: 01-Jul-1996 Ending: 31-Dec-1996 i

Page:

1 j

Location Name ROADSIDE PARK j

Distance (kilometers) 1.18E+00 Sector WNW l

Occupancy Factor 2.28E-04 (2.00E+00 hr/yr)

Age Group CHILD i

Ground Level Releases:

i i

Noble Gas X/Q (sec/nG) 7.83E-06 Particulate X/Q (sec/m3) 7.00E-06 Particulate D/Q (m-2) 2.01E-08 i

j Mixed Mode Releases i

Noble Gas X/Q (sec/nG)

N/A Particulate X/Q (sec/nG)

N/A 3

Particulate D/Q (m-2)

N/A Elevated Releases:

i Noble Gas X/Q (sec/nG) 2.42E-08 Particulate X/Q (sec/m3) 2.37E-08 i

Particulate D/Q (m-2) 1.29E-09 Units Quarter 3 Quarter 4 Quarters Year to 3 and 4 Ending Date Bone mrem 8.36E-06 9.14E-06 1.75E-05 3.02E-05 Liver mrem 8.68E-06 9.43E-06 1.81E-05 2.90E-05 TBody mrem 8.62E-06 9.35E-06 1.80E-05 2.89E-05 Thyroid mrem 2.98E-05 3.64E-05 6.62E-05 1.12E-04 Kidney mrem 8.75E-06 9.52E-06 1.83E-05 2.93E-05 Lung mrem 8.71E-06 9.46E-06 1.82E-05 3.30E-05

...-LLI GI mrem 8.61E-06 9.34E-06 1.80E-05 2.90E-05 v

. - _ _ _ _ ~. _ _. -. _ _..

i TABLE 4-1 E. I. HATCH NUCLEAR PLANT ANNUAL RAD 10 ACTIVE EFFLUENT RELEASE REPORT - 1996 i

DOSE TO A MEMBER OF THE PUBLIC DUE TO ACTIVITIES INSIDE THE SITE BOUNDARY i

Unit: Site i

Starting: 01-Jul-1996 Ending: 31-Dec-1996 J

Page:

2 Location Name CAMPING AREA i

Distance (kilometers) 1.27E+00 Sector WNW Occupancy Factor 5.48E-03 (4.80E+01 hr/yr)

Age Group CHILD Ground Level Releases.

Noble Gas X/Q (sec/m3) 7.03E-06 i

Particulate X/Q (sec/m3) 6.27E-06 Particulate D/Q (m-2) 1.80E-08 J

Mixed Mode Releases:

Noble Gas X/Q (sec/m3)

N/A Particulate X/Q (sec/m3)

N/A O

Particulate D/Q (m-2)

N/A V

Elevated Releases:

Noble Gas X/Q (sec/m3) 2.38E-08 Particulate X/Q (sec/m3) 2.33E-08 Particulate D/Q (m-2) 1.21E-09 Units Quarter 3 Quarter 4 Quarters Year to 3 and 4 Ending Date Bone mrem 1.82E-04 1.99E-04 3.81E-04 6.57E-04 Liver mrem 1.89E-04 2.05E-04 3.94E-04 6.31E-04 TBody mrem 1.87E-04 2.03E-04 3.91E-04 6.28E-04 Thyroid mrem 6.44E-04 7.85E-04 1.43E-03 2.43E-03 Kidney mrem 1.90E-04 2.07E-04 3.97E-04 6.37E-04 Lung mrem 1.89E-04 2.06E-04 3.95E-04 7.17E-04

....-LLI GI mrem 1.87E-04 2.03E-04 3.90E-04 6.31E-04 V.

}

73t'-)

TABLE 4-1 E.

I. HATCH NUCLEAR PLANT l

l ANNUAL' RADIOACTIVE EFFLUENT RELEASE REPORT - 1996 DOSE TO A MEMBER OF THE PUBLIC DUE TO ACTIVITIES INSIDE THE SITE BOUNDARY

'Tnit: Site i

Starting: 01-Jul-1996 Ending: 31-Dec-1996 Page:

3 Location Name RECREATION AREA Distance (kilometers) 1.03E+00 Sector SSE Occupancy Factor 2.37E-02 (2.08E+02 hr/yr)

Age Group CHILD Ground Level Releases:

Noble Gas X/Q (sec/m3) 6.42E-06 Particulate X/Q (sec/m3) 5.73E-06 Particulate D/O (m-2) 2.36E-08 Mixed Mode Releases:

Noble Gas X/Q (sec/m3)

N/A

)

Particulate X/Q (sec/m3)

N/A Particulate D/Q (m-2)

N/A

)

tA l

m-Elevated Releases:

Noble Gas X/Q (sec/m3) 3.30E-08 Particulate X/Q (sec/m3) 3.21E-08 Particulate D/Q (m-2) 1.56E-09 1

1 Units Quarter 3 Quarter 4 Quarters Year to i

3 and 4 Ending Date Bone mrem 7.25E-04 7.91E-04 1.52E-03 2.62E-03 Liver mrem 7.52E-04 8.16E-04 1.57E-03 2.52E-03 j

TBody mrem 7.47E-04 8.09E-04 1.56E-03 2.50E-03 Thyroid mrem 2.55E-03 3.11E-03 5.66E-03 9.63E-03 j

Kidney mrem 7.58E-04 8.24E-04 1.58E-03 2.54E-03 Lung mrem 7.54E-04 8.19E-04 1.57E-03 2.65E-03 GI-LLI mrem 7.46E-04 8.08E-04 1.55E-03 2.52E-03 I

,V 4

TABLE 4-1 E. I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 1996 DOSE TO A MEMBER OF THE PUBLIC DUE TO ACTIVITIES INSIDE THE SITE BOUNDARY Unit: Site Starting: 01-Jul-1996 Ending: 31-Dec-1996 Page:

4 Location Name VISITORS CENTER Distance (kilometers) 6.94E-01 Sector WSW Occupancy Factor 4.57E-04 (4.00E+00 hr/yr) i Age Group CHILD Ground Level Releases:

Noble Gas X/Q (sec/m3) 1.87E-05 Particulato X/Q (sec/m3) 1.72E-05 Particulate D/Q (m-2) 5.47E-08 Mixed Mode Releases:

Noble Gas X/Q (sec/m3)

N/A Particulate X/Q (sec/m3)

N/A i

Particulate D/Q (m-2)

N/A l(

4 Elevated Releases:

j Noble Gas X/O (sec/m3) 5.00E-08 Particulate X/Q (sec/m3) 4.97E-08 Particulate D/Q (m-2) 2.26E-09 Units Quarter 3 Quarter 4 Quarters Year to 3 and 4 Ending Date Bone mrem 3.79E-05 4.13E-05 7.92E-05 1.36E-04 Liver mrem 3.95E-05 4.28E-05 8.23E-05 1.30E-04 TBody mrem 3.92E-05 4.24E-05 8.16E-05 1.30E-04 Thyroid mrem 1.43E-04 1.75E-04 3.19E-04 5.41E-04 Kidney mrem 3.98E-05 4.32E-05 8.30E-05 1.32E-04 Lung mrem 3.96E-05 4.29E-05 8.25E-05 1.50E-04 GI LLI mrem 3.91E 4.23E-05 8.15E-05 1.30E-04

........................-05 i

O IV 1

~.

I 6.0 Major Changes to Liquid, Gaseous, and Solid Radwaste Treatment Systems The Radioactive Emuent Release Report shat! include.... any major change to liquid, gaseous, or solid radwaste treatment systems pursuant to ODCM d

l Chapter 7, Section 7.2.2.7.

1 Gaseous Radwaste System i

There were no major changes to the gaseous radwaste system during this reporting period.

4 Solid Radwaste System There were no major changes to the solid radwaste system during this reporting period.

Liquid Radwaste System There were no major changes to the Liquid Radwaste Treatment System during this reporting period.

7.0 Meteorological Data O

The neoioective effioemi neie aenori. to be ve iiteo er er 4 of esc 8 veer.

u shall include an annual summary of hourly meteorological data collected over the previous year. This annual summary may be either in the form of an hour-by-hour listing of wind speed, wind direction, atmospheric stability, and precipitation (if measured), on magnetic tape, or, in the form of joint frequency distribidions of wind speed, wind direction and atmospheric stability.

4 in lieu of submission with the Radioactive Emuent Release Report, the licensee has retained this surnmary of required meteorological data on site in a file. It will be provided to the NRC upon request.

8.0 Inoperable Liquid or Gaseous Effluent Monitoring instrumentation ODCM, Chapter 7, Section 7.2.2.6.2 states that the Radioactive Effluent Release Report shall include deviations from the liquid and gaseous effluent monitoring instrumentation operability requirements included in sections 2.1.1 and 3.1.1, respectively.

O.

i f

9 Specifically, Section 2.1.1, Table 2-1, Radioactive Liquid Effluent Monitoring

  • \\

instrumentation, Action 102, states that with the number of channels operable less than required, by the minimum channels operable requirement, effluent releases via this pathway may continue provided the flowrate is estimated at least once per 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />. If the channel remains inoperable for over 30 days, an explanation of the circumstances must be included in the next Radioactive Effluent Release Report.

i The Unit One Liquid Discharge Flow Rate Recorder 1G11-R037 was declared 3

i inoperable on June 11,1996, due to spiking and erratic readings. The cause for the spiking and erratic rea, dings was determined to be a bad transmitter. The transmitter was replaced tvith a new type of transmitter. After the installation of the new transmitter, and the calibration of the flow recorder, erratic readings and l

spiking ceased. The Unit One Liquid Discharge Flow Rate Recorder was placed back into service on August 16,1996.

4

?

9.0 Tanks Exceeding Curie Content Limits 3.15.1.4 (a): The contents within any outside temporary tank shall be limited to I

s; 10 curies, excluding tritium and dissolved or entrained noble gases.

There were no outside temporary tanks utilized during this reporting period.

l I

i 4

I O

.~..... -. -.. -.- - -.-.....=. -.. -.

i j

i.

GEORGIA POWER COMPANY E. I. HATCH NUCLEAR PLANT UNITS NO.1 & 2 ANNUAL REPORT JANUARY 1,1996 - DECEMBER 31,1996 APPENDIX A O

O

.