ML20092K252
| ML20092K252 | |
| Person / Time | |
|---|---|
| Site: | Hatch |
| Issue date: | 12/31/1994 |
| From: | GEORGIA POWER CO. |
| To: | |
| Shared Package | |
| ML20092K241 | List: |
| References | |
| NUDOCS 9509250295 | |
| Download: ML20092K252 (6) | |
Text
..
= _
+
s a
Enclosure Revised Pages Plant Hatch Annual Radioactive Effluent Release Report i
1994 Contents Table No.
Page No.
1-2BB 10 1-2CC 11 1-3BB 20 1-3CC 22 1-4BB 27 i
- Hi.4011 9507250295 950919 PDR ADOCK 05000321
..R..
._PDR j
I i
TABLE 1-2BB l
E.
I. HATCH NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 1994 Liquid Effluents - Summation of All Releases Unit: 2 Starting :
1-Jul-1994 Ending : 31-Dec-1994 TYPE OF EFFLUENT UNITS QUARTER 3 QUARTER 4 EST. TOT ERROR %
1 A. FISSION & ACTIVATION PRODUCTS i
- 1. TOTAL RELEASE (NOT INCLUDING TRITIUM,. GASES, ALPHA)
CURIES 9.14E-03 3.36E-03 4.70E+01
- 2. AVERAGE DILUTED CONCENTRATION DURING PERIOD uCi/ML 1.26E-08 6.92E-09
- 3. PERCENT OF APPLICABLE LIMIT B. TRITIUM
- 1. TOTAL RELEASE CURIES 2.87E+00 1.70E+00 3.70E+01
- 2. AVERAGE DILUTED CONCENTRATION J
DURING PERIOD uCi/ML 3.97E-06 3.50E-06
- 3. PERCENT OF APPLICABLE LIMIT C. DISSOLVED AND ENTRAINED GASES
................................................................................ j
- 1. TOTAL RELEASE CURIES 2.10E-03 1.68E-03 1.00E+02 l
- 2. AVERAGE DILUTED CONCENTRATION DURING PERIOD uCi/ML 2.91E-09 3.46E-09
- 3. PERCENT OF APPLICABLE LIMIT D. GROSS ALPHA RADIOACTIVITY B. WASTE VOL RELEASED (PRE-DILUTION)
LITERS 2.89E+06 1.88E+06 1.00E+01 F. VOLUME OF DILUTION WATER USED LITERS 7.22E+08% '4.8SE+08 1.60E+02 Applicable limits are expressed in tenus of dose.
See Tables 1-4A and 1-4B of this report. Rev. 1, 8/95
~ _
.e j
i i
1 TABLE 1-2CC 4
E. I. HATCH NUCLEAR PLANT ANNUE RADIOACTIVE EFFLUENT RELEASE REPORT - 1994 Liquid Effluents - Sununation of All Releases Unit: Site i
Starting :
1-Jul-1994 Ending : 31-Dec-1994 1
TYPE OF EFFLUENT UNITS-QUARTER 3 QUARTER 4.
EST. TOT ERROR %
t i
~A.
FISSION te ACTIVATION PRODUCTS
+
4
'1. 'IVTE RRLRERE (NOT INCLUDING i
TRITIUN, GASES, ALPHA) '
CURIES 1.528-015
_3.91E-01 M. ;4.70E+01
- 2. AVERAGE DILUTED CONCENTRATION DURING PERIOD uCi/ML 5.94E-08 2.11E.07 5
i
- 3. PERCENT OF APPLICABLE LIMIT B. TRITIUM j
- 1. TOTE RELEASE CURIES 9.96E+00 1.10B+01 3.70E+01 i
1
- 2. AVERAGE DILUTED CONCENTRATION DURING PERIOD uCi/ML-3.90E-06 5.95E-06
- 3. PERCENT OF APPLICABLE LIMIT f
I C. DISSOLVED AND ENTRAINED GASES
- 1. TOTAL RELEASE CURIES 3.58E-03 2.42E-03 1.00E+02
- 2. AVERAGE DILUTED CONCENTRATION DURING PERIOD uCi/ML 1.40E.09 1.31E.09
- 3. PERCENT OF APPLICABLE LIMIT D. GROSS ALPHA RADIOACTIVITY
- 1. TOTE RELEASE CURIES 0.00E+00 0.00E+00 1.20E+02 E. WASTE VOL RELEASED (PRE-DILUTION)
LITERS 9.62E+06 7.40E+06 1.00E+01 F. VOLUME OF DILUTION WATER USED LITERS 2.55E+09 1.85E+09 1.60E+02 Applicable limits are expressed in terms of dose.
See Tables 1-4A and'l-4B of this report. Rev. 1, 8/95
.1 l
i TABLE 1 3BB*
E. I. HATCH NUCLEAR PLANT I
ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 1994 Liquid Effluents Unit: 2 Starting :
1-Jul-1994 Ending : 31-Dec-1994 J
l CONTINUOUS MODE **
l BATCH MODE-l
]
NUCLIDE:
l UNIT l QUARTER 3 l QUARTER 4 l QUARTER 3ll QUARTER 4-l 1
'x W H-3 l
CURIES l 0.00E+00 l 0.00E+00 l 2.87B+00-l 1.70B+00 l
]
-1 i
1 FISSION & ACTIVATION PRODUCTS AS-76 CURIES 0.00E+00 0.00B+00 3.66E-04 0.00E+00 BA-139 CURIES 0.00B+00 0.00B+00 0.00B+00 4.55E-06 BA-140 CURIES 0.00E400 0.00E+00 3.77E-04 3.47E-06 CE-141 CURIES 0.00E+00 0.00E+00 1.90E 0.00E+00 CO-58 CURIES 0.00E+00 0.00E+00 2.39E-05
-1.52E-05 CO-60 CURIES 0.00B+00 0.00E+00 1.15E-03 7.76B-04 CR-51 CURIES 0.00E+00 0.00E+00 0.00E+00 1.73E-05 CS-134 CURIES 0.00E+00 0.00E+00 1.36E-05 3.90E-05 CS-137 CURIES 0.00E+00 0.00E+00 4.10E-04 2.715 04 i
FE-55 CURIES 0.00E+00 0.00E+00 2.08E-03 1.09E-04 FE-59 CURIES 0.00E+00 0.00E+00 0.00E+00 2.61E-06 I-131 CURIES 0.00E+00 0.00E+00 1.51E-04 5.31E-05 I-133 CURIES 0.00E+00 0.00B+00 3.94E-04 1.55E-04 LA-140 CURIES 0.00E+00 0.00E+00 1.12E-04 0.00E+00 MN-54 CURIES 0.00E+00 0.00E<.00 9.49E-05 1.52E-04 MD-99 CURIES 0.00E+00 0.00E+00 7.12E-05 0.00E+00 NA-24 CURIES 0.00B+00 0.00E+00 2.17E-04 0.00E+00 NB-95 CURIES 0.00E+00 0.00E+00 6.14E-07 0.00E+00 NB-97 CURIES 0.00E+00 0.00E+00 8.675-05 0.00E+00 NP-239 CURIES
.0.00E+00 0.00E+00 1.878-05 0.00E+00 OTHER CURIES 0.00E+00 0.00E+00 8.63B-04 4.26E-04 SR-89 CURIES 0.00E+00 0.00E+00 2.77E-04 7.51E-05 SR-90 CURIES 0.00E+00 0.00E+00 1.41E-05 1.07E-12 SR-91 CURIES 0.00B+00 0.00E+00 8.51E-06
.0.00E+00 TC-99Mt CURIES 0.00E+00 0.00E+00 1.18E-04 3.465-06 Y-91M CURIES 0.00E+00 0.00E+00 1.37E-05 2.32E-05
.Y-92 CURIES 0.00E+00 0.00B+00 3.72E-04 0.00E+00 ZN-65.
CURIES 0.00E+00 0.00E+00 1.90E-03 1.23E-03 ZN-69M CURIES 0.00E+00 0.00E+00 8.968-06 0.00E+00 TOTALS l
CURIES l 0.00E+00-l 0.00E+00 l 9.14E-03 l 3.36E-03 l DISSOLVED AND ENTRAINED GASES
................................................................................ Rev. 1, 8/95 1
I
.i TABLE 1-3CC*
E. I. HATCH NUCLEAR' PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 1994 Liquid Effluents
- Unit: Site Starting : '1-Jul-1994 Ending : 31-Dec-1994 i
l CONTINUOUS MODE **
l
' BATCH MODE-l l
,,I b sc
,.y iH-3 l
CURIES ~ l 0.00E+00-l 0.00E+00 l 9.96E+00 l 1.10E+01 l
. FISSION & ACTIVATION PRODUCTS AS-76 CURIES 0.00E+00 0.00E+00 1.99E-03 3.73B-04 BA-139 CURIES 0.00E+00 0.00E+00 4.47E-06 4.55E-06 BA-140 CURIES 0.00E+00 0.00E+00 1.58E-03 3.47B-06 CE-141 CURIES 0.00B+00 0.00E+00 6.68E-06 0.00E+00 CE-144 CURIES 0.00E+00 0.00B+00 7.23E-06 2.265-04 CO CURIES 0.00E+00 0.00E+00 0.00E+00 1.10E-05 CO-58 CURIES 0.00E+00 0.00E+00 4.67E-04 1.11E-02 CO-60 CURIES 0.00E+00 0.00E+00 8.59E-03 7.48E-02 CR-51 CURIES 0.00E+00-0.00E+00 9.08E-04 5.61E-02 CS-134 CURIES 0.00E+00 0.00E+00 4.868-04 2.1SE-04 CS-137 CURIES 0.00E+00 0.00E+00 7.58E-03 5.378-03 FE-55 CURIES 0.00E+00 0.00E+00 3.258-03 1.27E-02 FE-59 CURIES 0.00E+00 0.00E+00 8.12E-05 1.47E-02 I-131 CURIES 0.00E+00 0.00E+00 3.67E-04 5.70E-05 i
I-132 CURIES 0.00E+00 0.00E+00 1.09E-04 0.00E+00 I-133 CURIES 0.00E+00 0.00E+00 1.55E-03 1.55B-04 I-135 CURIES 0.00E+00 0.00R+00 2.86E-04 0.00E+00 LA-140 CURIES 0.00E+00 0.00E+00 3.08E-04 0.00E+00 MN-54 CURIES 0.00E+00 0.00E+00 1.34E-03 3.06E-02 MN-56 CURIES 0.00E+00 0.00E+00 3.00E-05 0.00B+00
.MD-99 CURIES 0.00E+00 0.00E+00 2.76E-04 0.00E+00.
NA-24 CURIES 0.00E+00 0.00B+00 6.38E 3.58E-05
-NB-95 CURIES 0.00E+00 0.00E+00 3.465-06 6.83E-04 NB-97 CURIES 0.00B+00 0.00E+00
-4.20E-04 2.98E-04 NP-239 CURIES 0.00E+00 0.00E+00 1.87E-05 0.00B+00 OTHER CURIES-
.0.00E+00 0.00E+00 9.96E-02' 8.90E-03 SB-124 CURIES 0.00E+00_
0.00E+00 2.40E-06 6.64E-04
~SN-113 CURIES 0.00E+00 0.00E+00' 0.00E+00 7.51E-06
'SR-89 CURIES 0.00E+00 0.00E+00 1.50E 3.00E-04 SR-90 CURIES 0.00E+00 0.00E+00 5.76E-05 1.21E-07 I
SR CURIES 0.00E+00 0.00B+00 8.518-06 0'.00E+00 SR-92 CURIES 0.00E+00 0.00H+00 2.22E-06 2.99E-05 i
-TC-99M CURIES 0.00E+00 0.002,+00 7.74E-04 1.64E-05 1 Rev.-1 8/95 i
1 m
L
, _ +
a j..
TABLE 1-4BB E.
I. HATCH NUCLEAR PLANT ANNUAL. RADIOACTIVE EFFLUENT RELEASE REPORT - 1994 DOSES TO A MEMBER OF THE PUBLIC DUE TO LIQUID RELEASES Unit: 2 j
Starting: 01-Jul-1994 Ending: 31-Dec-1994 i
3 i
j Cumm11ative Doses per Quarter l
Organ ODCM Units Quarter
% of Quarter
% of Limit 3
ODCM 4
-Limit' Limiti 4
u
-Bone 5.0 mrem 1.91E-03 3.83E-02 1.24E-03 2.478-02 l
Liver 5.0 mrom 3.04E-03 6.07E 2.08E-03 4.16E-02 TBody 1.5 mrem 1.93E-03 1.298-01 1.35E-03 8.99E-02 Thyroid 5.0 mrem 1.19E-03 2.39E-02 4.52E-04 9.04E-03 Kidney 5.0 mrem 1.28E-03 2.55E-02 8.53E-04 1.71B-02 l
Lung.
5.0 mrem 2.79E-04 5.588-03 1.92E-04 3.84B-03 GILLI 5.0 mrem 1.21E-03 2.42E-02 7.69E-04 1.54E-02 3
{
Cumulative Doses per Year Organ ODO6 Units Year to
% of Limit Ending ODCM Date Limit Bone 10.0 mrem 3.61E-02 3.61E-01 Liver 10.0 mrem C.91E-02 6.91E-01 TBody 3.0 mrom 4.24E-02 1.41E+00 l
Thyroid 10.0 mrem 3.73E-02 3.73E-01 Kidney 10.0 mrem 3.27E-02 3.27E-01 Lung 10.0 mrem 4.55E-03 4.55E-02 l
GILLI 10.0 mrem 4.09E-02 4.09E-01
.ef s '
Rev. 1, 8/95
-