Monthly Operating Rept for Feb 1992 for Monticello Nuclear Generating Plant
ML20090H429
Person / Time
Site: Monticello Xcel Energy icon.png
Issue date: 02/29/1992
From: Parker T, Paustian H
NORTHERN STATES POWER CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NUDOCS 9203160071
Download: ML20090H429 (5)


Text

...,.

i' Northem States Power Company 414 Nico!!st Mall Minneapolis. Minnesota 55401 1927 Telephone (612) 330-5500 March 6, 1992 Monticello Technical Specifications Section 6.7 A.3 US Nuclear Regulatory Commission Attn: Document Control Desk Vashington, DC 20555 MONTICELIA NUCLEAR CENERATING PIANT Docket No. 50 '63 License No. DPR-22 Monthly Operating Report

&_b yarv 1992 l

attached is the Monthly Operating Report for February 1992 for the Monticello i

Nuclear Generating Plant.

/

h%% ' &nd

/ Thomas M Parker Managar Nuclear Support Service TMP/mk1 C:

Director, Office of Resource Management Regional Administrator-III, NRC NRR Project Manager, NRC NRC Resident Inspector MPCA Attu: J-V Ferman Attachment

{

l4l/

l

/

ll 9203160071 920229 1

ADOCF.OSOOg3 PDR y

R

- OPERATING DATA REPORT-

, l DOCKET NO.

50-263 DATE 3-2-92

+-

COMPLETED BY H..H.-Paustian-l TELEPHONE 612/295-5151

-OPERATING-STATUS'

) Notes-

)

11. Unit.Name :

Monticello

)

-)-

? 2 '. 3 Reporting period:

February

)

]

.3. Licensed Thermal Power (MWt):

-1670

]

]

4.. Nameplate Rating (Gross-MWe):

569

);

-)

L5; Design Electrical. Rating (Net MWe):

545.4

)

-l'

'6.1 Maximum Dependable Capacity-(Gross MWe): __564

)

)

2 i7 ' Maximum Dependable Capacity-(Net MWe):

536

-)

-) -

8. If Changes Occur in Capacity Ratings (Items Number 3 Through 7) Since Lc.st:

Report, Give Reasons:

9. Power' Level To Which Restricted, If Any-(Net MWe):

N/A L10; Reasons For.. Restrietions, If Any:

N/A THIS MONTH-YR TO-DATE CUMULATIVE EHours"In Reporting ~ Period' 696 1440 181177 t

311.:

12..' Number OfEHours Reactor.Was Critical 696.0 1371.1 144789.5

.13.iReactor Reserve Shutdown Hours 0.3 0.' O 940.7 (14. Hours Generator lOn-Line 696.0 1352.8 142100.7 115. Unit Reserve Shutdown Hours 0.0 0.0

-0. 0 i

,* S16." Gross Thermal Energy Generated (MWH) 1159351 2237544 217771121 117.-Gross Electrical-Energy Generated (MWH) 390548

'753411 73643256

~

'18;: Net Electrical-Energy _ Generated (MWH) 376110 724510 70426728 100.0%-

93.9%

78.4%

19. Unit Service Factor 20;LUnic Availability Factor-100.0%

93.9%

78.4%

(21., Unit 4 Capacity Facto lr (Using MDC Net) 100.8%

93.9%

72.5%-

22'.-Unit' Capacity Factor 1(Using DER' Net) 99.1%.

92.3%

.-71.3%.

23.
UnitLForced Outage Rate 0.0%

4,8%

3.9%'

,24. Shutdowns Scheduled'Over Next 12' Months (Type, Date, and Duration of Each)

Refueling Outage - 1/6/93 - 56 days
25. If Shut Down At End Of Report Period, Estimated Date Of Startup:N/A D26'. Units In. Test. Status (Prior to Commercial Operation): N/A Forecast' Achieved.

. INITIAL CRITICALITY a"

INITIAL ELECTR10ITY COMMERCIAL OPERATION-I t

. +,

s-,,-v

,w, c.,-.--.

.y

,-e.

w w

NARRATIVE-

SUMMARY

OF-OPERATING EXPERIENCE

..s DOCKET NO.

50-263

DATE 3-2-92 DMPLETED BY H,H.

Paustian TELEPHONE 612/295-5151

-u

,,,-.y i,'

, MONTH __

FEB

'~

2-1-92 to--

Power operation. 29-92 l

0 l

l.

!fj-

( "

L:

I L.

l l-i-

l I,

Note: - Power operation defined as essentially 100% of -

- rated power:except for weekend load drops for specified surveillance testing.

,'f--

a f

y e

4

AVERAGE DAILY UNIT POWER LEVEL 4

i j

4 DOCKET NO.

50-263 UNIT Monticello.__

DATE 3-2-92 COMPLETED BY H.

H.

Paustian TELEPHONE 612/295-5151 MONTH OF February DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net)

(MWe-Net) 1 534.

17 541..

2 539.

18 542.

3

541, 19 541.

4

543, 20

_541.

3-539.

21

538, 6
543, 22

'40.

,.\\

7

S42, 23

.543.

8

__542, 24 533.

9 542.

25

____5 51.

-10 542.

26 542. 520.

27 539.

f 121 540.

28 543.__

13

541, 29 540.

. 14 543.

e 15 545.

16 541.

INSTRUCTIONS On this format, list the average daily unit power level in MWe-Net for each day in the reporting month.

Compute to the nearest whole megawatt.

~

. UNIT SHUT 00WIIS A!D EGiER REEOCTIGS DOCEP 10. ~Yonticello

~

  • 50-263 UNIT IIA!G re.TE ~03-02-92 CQ4PLETED BY 11. H. Paustien REPORT 1CGI _, February TEEPHGE _612/205-5251~

l~

l I

ib.

Date Type Duration Reason Method LERl System Cci@de Action to i

Cause & Corrective (1)

OrAirs) i2) of

.t No, Code Co Shutdown (4)

(5)

Prevent Pecurrence f3)

Ibne 1

/

3 l

l l

1 2

3 4

lbthoi:

Draft IEEE Standard F: Forced Reason:

S: Scheduled A-Fq;iprrent F4ilure (Explain) 1-Manual 805-J84(F805-DS)

B-;&nntenance or Test 2-Manual Scram C-Refualing 3-Autcxrntic Scram 5

D-Fegulator Bestriction 4-Other (Explain)

IEEE Standard 803A-1983 E-Operncr Training & License Examination F-Acrin:Strative G-rational Error (Explain)

H-her t. Explain) g. _

,