7
.. i VERMONT YANKEE NUCLEAR POWER CORPORATION - i i
1993 INSERVICE INSPECTION
SUMMARY
REPORT i SEPTEMBER 1,1993, THROUGH OCTOBER 27,1993 j i -!
i
'h i
i i
i i
Prepared By: // / /# Alm ///r NV ,
YNSD INSERVICE INSPECTION COORDINATORS .
i
' Reviewed By: murd b 2N n<<!4 8a'!PM -
PLANT INSERVICE INSPECTION COORDINATOR j Approved By: /- '
/-
L- ME AN 'l E4dlNEERING AND CONSTRUCTION SUPERVISOR i
i 9402O20320 940124 l PDR
~Q ADDCK 05000271 PDR d(( '
6 l--
. 7.
y ,
VERMONT YANKEE NUCLEAR POWER CORPORATION -
1993 INSERVICE INSPECTION
SUMMARY
REPORT '
SEPTEMBER 1,1993, THROUGH OCTOBER 27,1993~
- 1. INTRODUCTION i The attached Form NIS-1, " Owner's Data Report for Inservice inspection," describesL [~
the inservice inspections performed during 1993 at the Vermont Yankee Nuclear Power Station, Vernon, Vermont. The examinations performed were those 'of the first outage .,
of the first period of the third ten-year interval. The nondestructive examination i procedures used for inservice inspection were in accordance with the ASME Boiler and !
Pressure Vessel Code,Section XI,1986 Edition, as referenced in the plant Technical :
Specifications. The areas subject to examination and the method used were in I accordance with the Vermont Yankee Inservice inspection Program and the plant !
Technical Specifications. This report summarizes the components examined, the types of examinations, the status of the current interval, the non-conforming conditions ;
noted, and the corrective actions taken. Ultrasonic, liquid penetrant, magnetic particle, a and visual examination techniques were employed to perform the required examinations.
- 2. EXAMINATION METHODS ,
Nondestructive examinations were performed in accordance with the procedures ,
contained in the Yankee Atomic Electric Company Engineering Guidelines, Book Ill,
" Inservice inspection NDE Procedures," or vendor procedures reviewed and approved by Yankee Atomic Electric Company. The examination procedures were reviewed and ,
approved by personnel qualified to SNT-TC-1 A, Level 111. These procedures conform' ,
to the requirements of ASME Section XI,1986 Edition. The inservice examinations l were performed and evaluated by personnel qualified as provided for in Section.XI. l The procedures used for these examinations are listed in Section 10 of the NIS-1 Furm.
- 3. EVALUATION OF DATA The examination results were performed and reviewed at the site by personnel j qualified to at least Level II in the examination discipline. Indications were evaluated j to the acceptance standards defined in the Vermont Yankee Nuclear Power Station j' Technical Specifications, ASME Section XI,1986 Edition, and the . Yankee Atomic Electric Company Engineering Guidolines, Book lit, " Inservice Inspection _ NDE 1 Proce A4rto ." j l
1-4 e - . .- ., w,,., ,- --,,n.- ,y - ,,
- n *
't FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES
- 1. Owner VERMONT YANKEE NUCLEAR POWER CORP.. R.D.5. BOX 169. FERRY ROAD.
BRATTLEBORO VT. 05354
- 3. Plant Unit 1 4. Owner Certificate of Authorization DPR-28
- 5. Commercial Service Date 11/30/72 6. National Board Number NONE
- 7. Components inspected SEE ATTACHED
- 8. Examination Dates September 1.1993. to October 27,199.3
- 9. Inspection Interval From 9/1/1993 To 8/31/2003
- 10. Applicable Editions of Section XI 1986 Addenda NONE
- 11. Abstract of Examination -- List of examinations and a statement concerning status of work-required for current interval. SEE ATTACHED
- 12. Abstract of Conditions Noted. _S.EE ATTACHED
- 13. Abstract of Corrective Measures Recommended and Taken SEE ATTACHED We certify that the statements made in this report are correct and the examinations and corrective measures taken conform to the rules of the ASME Code,Section XI.
Date //2a/W Signed Vermont Yankee N.P.C. By </u'd /4N m v P'lan nager ////
Certificate of Authorization No. DPR-28 Expiration Date 12/11/2007 CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vesselinspectors and/or the State or Province of Vermont and employed by Arkwrioht'of Norwood Massachusetts. have inspected the components described in this Owner's Data Report during the period Seotember 1.1993 to October 27.1993 and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.' Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
qh?/fhf g ;l,; ', '
- ^"**}/f~y f ~ f j) . x/
Inspector's Signature National Board, State, Province, and Endorsements Date /~ U 19
FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS - ~
AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES ,'
Vermont Yankee Nuclear Power Corp.
Vermont Yankee Nuclear Power Station Owner Certification: DPR-28
- Commercial Service Date: 11/30/72 Page 4 of 16 Components Inspected / Abstract of Examinations Section 7/11 Code Cat item ID Exam System Drawing Results B-D N4A UT RPV ISI-RPV-103 ACCEPTED (Acceptable Indication)
B-D N4B UT RPV ISI-RPV-103 ACCEPTED (Acceptable Indication)
B-D N4C UT RPV iSI-RPV-103 ACCEPTED .
B-D N4D UT RPV ISI-RPV-103 ACCEPTED B-F N10-SE PT RPV ISt-RPV-103 ACCEPTED B-F CU400-F9 PT RWCU 1S1-5920-6622 ACCEPTED B-F CU400-F12 PT RWCU iSI-5920-6622 ACCEPTED
-B-G-2 18-11 VT-1 CRD ISI-RPV-104 ACCEPTED B-G-2 18-15 VT-1 CRD ISI-RPV-104 ACCEPTED B-G-2 18 VT-1 CRD ISI-RPV-104 ACCEPTED '
B-G-2 26;19 VT-1 CRD ISI-RPV-104 ACCEPTED B-G-2 02-19 VT-1 CRD ISI-RPV-104 ACCEPTED B-G-2 14-23 VT-1 CRD ISI-RPV-104 ACCEPTED B-G-2 26-39 VT-1 CRD ISI-RPV-104-' ACCEPTED.
B-G-2 30-07 VT-1 CRD ISI-RPV-104 ACCEPTED B-G-2 30-15 VT-1 CRD ISI-RPV-104 ACCEPTED j E_______.___-._ _ _ ._ _ _ _ _ _ . - _ _ . - __ _ _ _ _ _ _._ . . _ . __ - _ . . _ ~_ _ . . . J . -. , . .
a' FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS .
AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES -
Vermont Yankee Nuclear Power Corp.
Vermont Yankee Nuclear Power Station Owner Certification: DPR-28 '
Commercial Service Date: 11/30/72 Page 5 of 16' Components inspected / Abstract of Examinations Section 7/11 Code Cat item ID Exam System Drawing Results B-G-2 30-35 VT-1 CRD ISI-RPV-104 ACCEPTED B-G-2 34-19 VT-1 CRD ISI-RPV-104 ACCEPTED B-G-2 38-31 VT-1 CRD ISI-RPV-104 ACCEPTED B-G-2 V2-43A VT-1 RECIRC 1S1-5920-6622 ACCEPTED (Successive Exam) ,
B-G-2 V10-17 VT-1 RHR ISI-5920-9283 ACCEPTED B-G-2 V10-81 B VT-1 RHR 1S1-5920-6622 1/3 ACCEPTED (Successive Exam)
B-G-2 N6A VT-1 RPV ISI-RPV-103 ACCEPTED B-J FW21-N48-SW MT- FW ISI-FDW-PART 5 ACCEPTED B-J FW21-N4B-SW UT FW- ISI-FDW-PART 5 ACCEPTED B-J FW18-N4C-SW MT FW ISI-FDW-PART SA ACCEPTED B-J . FW 18-N4C-SW UT FW ISI-FDW-PART 5A ACCEPTED B-J FW20-N4D-SW 'MT FW ISI-FDW-PART SA ACCEPTED -
B-J FW20-N4D-SW UT FW ISI-FDW-PART SA ACCEPTED B-J FW19-F7 MT FW ISI-FDW-PART 5 ACCEPTED B-J- FW19-F7 UT FW ISI-FDW-PART 5 ACCEPTED B-J FW21-F3 MT FW ISI-FDW-PART 5 ACCEPTED
- _ _ _ _ . _ . . - . . . .. _ . - _,. - .. . ._~ _._ _ _ _
1 .
~
FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS .
AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES l
Vermont Yankee Nuclear Power Corp. -
Vermont Yankee Nuclear Power Station Owner Certification: DPR-28 Commercial Service Date: 11/30/72 Page 6 of.16 Components inspected / Abstract of Examinations Section 7/11 Code Cat item ID Exam System Drawing Results .
B-J FW21-F3 UT FW ISI-FDW-PART 5 ACCEPTED (Geometry)
B-J FW18-F6 MT FW ISI-FDW-PART SA ACCEPTED B-Li FW1 E-F6 UT FW ISI-FDW-PART SA ACCEPTED (Geometry)
B-J FW13-N4A-SW !.T FW ISI-FDW-PART 5 ACCEPTED B-J FV 19-N4A-SW UT FW ISI-FDW-PART 5 ACCEPTED B-J PN20-F4 MT FW ISI-FDW-PART 5A ACCEPTED B-J FW20-F4 ' UT FW ISI-FDW-PART 5A ACCEPTED ;
B-J MSD2-S4 MT ' MN ST ISl-RPV-105 ACCEPTED B-J MSD2-F1 MT MN ST ISI-RPV-105 ACCEPTED B-J RR-AS-5 PT- RECIRC 151-5920-6622 ACCEPTED B-J RR-AS-5 UT RECIRC ISI-5920-6622 ACCEPTED B-J. RR-AS-6 PT RECIRC 1S1-5920-6622 ACCEPTED B-J RR-AS-6 UT RECIRC 1S1-5920-6622 ACCEPTED B-J- RR-AD PT RECIRC ~ ISI-5920-6622 ACCEPTED B-J . RR-AD-8 UT RECIRC ~ ISI-5920-6622 ACCEPTED B-J RR-AB-2 PT RECIRC ' 1S1-5920-6622 ACCEPTED-
._ _ _ _ _ _ _ _ _ _ _ _____.-_._____.1. _ - _ _ - _ . . . . . . _ . _ . . , . . _ . .. - _ ___ . .a_. . . . _ . _ . , . _ _ -. ..
w-
.~
FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS .
AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES [
Vermont Yankee Nuclear Power Corp.
Vermont Yankee Nuclear Power Station Owner Certification: DPR-28 ~
Commercial Service Date: 11/30/72 Page 7 of 16 '
Components inspected / Abstract of Examinations Section 7/11 Code Cat item ID Exam System Drawing Results-B-J RR-AB-2 UT RECIRC 1S1-5920-6622 ACCEPTED B-J RR-AB-3 PT RECIRC ISI-5920-6622 ACCEPTED B-J RR-AB-3 UT RECIRC 1S1-5920-6622 ACCEPTED B-J RR-AB-7 PT REClRC 1S1-5920-6622 ACCEPTED B-J RR-AB-7 UT RECIRC 151-5920-6622 ACCEPTED B-J RR-AB-8 PT RECIRC 1S1-5920-6622 ACCEPTED B-J RR-AB-8 UT RECIRC 1S1-5920-6622 ACCEPTED B-J CU 19-F1 'PT RWCU 151-5920-6622 ACCEPTED B-J CU 19-F8 PT RWCU 1S1-5920-6622 1/3 ACCEPTED B-J CU19-F9 PT RWCU 1S1-5920-6622 1/3 ACCEPTED B.{ CU 19-FW3 PT RWCU 1S1-5920-6622 ACCEPTED B-J CU 19-FW2 PT RWCU 151-5920-6622 ACCEPTED B-J SL11-F12 PT SLC ISI-SLC-PART 4 ACCEPTED B-M-2 V10-17 - VT-3
. RHR 1S1-5920-9283- ACCEPTED B-N-2 Steam Dryer Support - VT-1 RPV ISI-RPV-103 NO CHANGE (From interval 2, Bracket at 215 Period 3, Outage 7)
_..-.: -.._m . . . . ~ ~ . #.v m. . , . -..,.-.c .,,.-o%.-, . - - - . . . * - , ,- ,.-e--;r~v e.w , ,- c.. e. , ,4-,-,--- ,e- .. - -, - ,, .-
.~
FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS .
AS REQUIRED BY:THE PROVISIONS OF THE ASME CODE RULES :
Vermont Yankee Nuclear Power Corp.
Vermont Yankee Nuclear Power Station Owner Certification: DPR-28 ,
Commercial Service Date: 11/30/72 Page 8 of 16' Components inspected / Abstract of Examinations Section 7/11 Code Cat item ID Exam System Drawing Results B-O O2-27SH UT CRD ISI-RPV-104 ACCEPTED B-O O2-27HF - UT CRD ISI-RPV-104 ACCEPTED C-C H103B MT HPCI ISI-HPCI-PART 3 ACCEPTED C-F-2 HP158-S103 MT HPCI IS!-HPCI-PART 4 ACCEPTED C-F-2 HP158-S103 UT HPCI ISI-HPCI-PART 4 ACCEPTED (Geometry)
C-F-2. MS48-S188 MT HPCI ISI-HPCI-PART 3 ACCEPTED C-F-2 MS4B-S188 UT HPCI ISl-HPCI-PART 3 ACCEPTED (Geometry)
C-F-2 .MS4B-S187 MT HPCI ISI-HPCI-PART 3 ACCEPTED C-F-2 MS48-S187 UT HPCI ISI-HPCI-PART 3 ACCEPTED (Geometry)
C-F-2 BPMP-T199 MT HPCI ISI-HPCI-PART 13A ACCEPTED C-F BPMP-T199 UT- HPCI ISI-HPCI-PART 13A ACCEPTED C-F-2 HP2-S18 MT HPCI ISI-HPCI-PART 4 ACCEPTED C-F-2 HP2-S18 UT HPCI ISI-HPCI-PART 4 ACCEPTED (Geometry)
C-F-2 HP3-T33 MT- HPCI 1S1-5920-9240 ACCEPTED C-F-2 HP3-T33 UT HPCI 1S1-5920-9240 ACCEPTED (Geometry)
C-F-2 HP3-S57 MTL HPCI ISI-5920-9240 : ACCEPTED
~
. ~
FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS ,
AS REGUIRED BY THE PROVISIONS OF THE ASME CODE RULES Vermont Yankee Nuclear Power Corp.
Vermont Yankee Nuclear Power Station Owner Certification: DPR-28 '
Commercial Service Date: 11/30/72 Page 9 of 16 Components inspected / Abstract of Examinations Section 7/11 2
Code Cat item ID Exam System - Drawing Results
-C-F-2 HP3-S57 UT HPCI ISI-5920-9240 ACCEPTED (Geometry) -
C-F-2 HP2-S26 MT HPCI ISI-HPCI-PART 41/1 ACCEPTED C-F-2 HP2-S26 UT HPCI ISI-HPCI-PART 41/1 ACCEPTED (Geometry)
D-X RSW-H191 VT-3 SW ISI-SW-PART 12 2/2 - ACCEPTED D-X RSW-H 194 VT SW ISI-SW-PART 12 2/2 ACCEPTED D-X RSW-H 195 VT SW ISI-SW-PART 121/2 ACCEPTED D-X RSW-H197 VT-3 SW ISI-SW-PART 131/2 ACCEPTED
-D-X RSW-H 198 - VT-3 SW ISI-SW-PART 121/2 ACCEPTED D-X RSW-H201 ~ VT-3 SW ISI-SW-PART 121/2 ACCEPTED D-X RSW-H205 VT-3 SW ISI-SW-PART 121/2 ACCEPTED D-X RSW-H204 VT-3 SW ISI-SW-PART 121/2 ACCEPTED D-X RSW-H 187 VT SW ISI-SW-PART 141/2 ACCEPTED D-X RSW-H200 VT-3 SW ISI-SW-PART 141/2 ACCEPTED D-X RSW-H102 VT-3 SW ISI-SW-PART 141/2 ACCEPTED F-A FW-11 & FW-22 VT-3 FW ISI-FDW-PART 5 & 5A ACCEPTED F-A FW-7 & FW-8 VT FW- ISI-FDW-PART 5 ACCEPTED (Successive Exam)
. - - . - _ - . _ - . _ _ _ _ - _ . - _ - -._ . . . . .- . , - . , . . - . . . . . . - . - - . - . . _ _____u _
~
FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIOMS ,
AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES :.
Vermont Yankee Nuclear Power Corp. -
Vermont Yankee Nuclear Power Station Owner Certification: DPR-28 ~
Commercial Service Date: 11/30/72 Page 10 of 16 Components inspected / Abstract of Examinations Section 7/11 Code Cat item ID. Exam System Drawing Results F-A H103B VT-3 HPCI ISI-HPCI-PART 3 CORRECTIVE ACTION - See Section 12/13 F-A HD-107A VT-3 HPCI ISI-5920-9240 ACCEPTED (Additional Exam)
F-A HD-107C VT-3 HPCI 151-5920-9240 CORRECTIVE ACTION - See Section 12/13 (Additional Exam)
F-A HD-108B VT-3 HPCI 1S1-5920-9240 ACCEPTED (Successive Exam)
F-A HD-1078 VT-3 HPCI 1S1-5920-9240 CORRECTIVE ACTION - See Section 12/13 F-A H-108 VT-3 HPCI 1S1-5920-9240 ACCEPTED F-A MS-H5 VT-3 HPCI ISI-HPCI-PART 2 ACCEPTED (Successive Exam)
F-A HD102DN VT-3 HPCI ISI-HPCI-PART 3 ACCEPTED (Successive Exam)
F-A MS-H 13 VT-3 HPCI ISI-HPCI-PART 3 ACCEPTED F-A HD-84 VT-3 HPCI 1S1-5920-9242. ACCEPTED (Additional Exam)
F-A MS-H22 VT-3 HPCI ISI-HPCI-PART 4 ACCEPTED F-A H32 VT-3 HPCI ISI-HPCI-PART 5 ACCEPTED (Aoditional Exam)
F-A HD35D ' VT-3 HPCI ISI-HPCI-PART 5 CORRECTIVE ACTION - See Section 12/13 (Additional Exam) .
[
~
FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS ,
AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES ;
Vermont Yankee. Nuclear Power Corp.
Vermont Yankee Nuclear Power Station Owner Certification: DPR-28
- Commercial Service Date: 11/30/72 Page 11 of 16 Components inspected / Abstract of Examinations p Section 7/11 Code Cat item ID Exam System Drawing Results I j F-A HD35C VT-3 HPCI ISI-HPCI-PART 5 . ACCEPTED (Additional Exam)
F-A HD103C VT-3 HPCI ISI-HPCI-PART 3 CORRECTIVE ACTION - See Section 12/13 F-A H-110 VT-3 HPCI 1S1-5920-9242 ACCEPTED F-A P-44-1 A SUPPORT VT-3 HPCI ISI-HPCI-PART 4 ACCEPTED F-A TU-1-1 A SUPPORT VT-3 HPCI 1S1-5920-9240 ACCEPTED F-A P-44-18 SUPPORT VT-3 HPCI ISt-HPCI-PART 13A ACCEPTED F-A MS-5 VT-3 MN ST ISI-RPV-105 ACCEPTED (Successive Exam)
F-A RCIC 1 VT-3 RCIC ISI-RPV-105 ACCEPTED (Successive Exam)
F-A RCIC 2 VT-3 RCIC ISI-RPV-105 ACCEPTED (Successive Exam)
F-A RR-11 VT-3 RECIRC 1S1-5920-6802 ACCEPTED l F-A ' RR-25 ' VT RECIRC lSI-5920-6802 - ACCEPTED F-A RR-13 VT-3 RECIRC 1S1-5920-6802 ACCEPTED F-A RR-12 VT-3 RECIRC 1S1-5920-6802: ACCEPTED ~
F-A : RR-27 VT RECIRC 1S1-5920-6802' ACCEPTED F-A - RR-26 VT-3 RECIRC 1S1-5920-6802 ACCEPTED i - -
^
FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS '
AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES - ,
Vermont Yankee Nuclear Power Corp. -
Vermont Yankee Nuclear Power Station Owner Certification: DPR-28 1 Commercial Service Date: 11/30/72 ,
Page 12 of 16 Components inspected / Abstract of Examinations Section 7/11 Code Cat item ID Exam System Drawing Results .
F-A H-189N VT-3 RHR ISI-RHR-PART 11 1/5 ACCEPTED (Successive Exam)
F-A H-129 VT-3 RHR 1S1-5920-9288 ACCEPTED (Sucr ,ssive Exam)
-- * * -, -ee * ..2%-.- -. , m .-, , .., ewe.+,w.,. 3 -i. -
, ,e-
FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIO'NS -
AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES j. .
Vermont Yankee Nuclear Power Corp. -
Vermont Yankee Nuclear Power Station Owner Certification: DPR-28 Commercial Service Date: 11/30/72 Page 13 of 16 Components inspected / Abstract of Examinations Section 7/11 Category Ouantity inspected Quantity Scheduled Percent of Third 1993 Outage for Third Interval Interval Complete B-A O 16 0%
B-D 4 29 14%
B-E O 31 0%
B-F 3 35 9%
B-G-1 0 81 0%
B-G-2 14 109 13 %
B-J 23 134 17%
B-K-1 0 14 0%
- B-L-2 O Relief Request N/A B-M-2 1 Relief Request N/A B-N-1 O Each Period 0%
B-N-2 Partial 1 N/A" B-O '2 -6 33%
C-A O 4 0%
C-B ~ O 4 0%
. .. .:. . ..-_ . _= : =, . .~ . . - . ... -. . . . . .. ~ . - . - . . .-
. FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS .
Vermont Yankee Nuclear Power Station
- Owner Certification: DPR-28 ,
Commercial Service Date: 11/30/72 Page 14 of 16 - _.
Components Inspected / Abstract of Examinations 1 Section 7/11 Category Quantity inspected : Quantity Scheduled Percent of Third
.1993 Outage . for Third Interval Interval Complete C-C 1 21 5% .i C-F-2 8 67- 12%
D-X 11 63 17 %
F-A 19 137 14%
3
.e 3
6 FORM NIS-1 OWNERS DATA REPORT FOR INSERVICE INSPECTIONS + - -i AS REQUIRED'BY THE PROVISIONS OF THE ASME CODE RULES- i-Vermont Yankee Nuclear Power Corp.
Vermont Yankee Nuclear Power Station Owner Certification: DPR-28 Commercial Service Date: 11/30/72 Pace 15 of 16 -
Pressure Tests Test I.DJ System Description RPV System and RPV System leakage test of the reactor coolant system boundary.
associated piping Vermont . Yankee procedure number OP-4101 SLC System RPV System leakage test of the Class 1 SLC system boundary. Vermont Yankee ~ procedure number OP-4101
}
r
_ _ _ _ _ _ _ _ _ _ . _ _ _ _ _ _ _ _ _ _ _ _ _ .-..,:- . ...2~. . , _ , . . . . . - . . . ..- -- -..~..-..,. ._.-. .
_,,.J.m ,~_.i__z___.
FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS- - I-AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES .i Vermont Yankee Nuclear Power Corp.
Vermont Yankee Nuclear Power Station Owner Certification: DPR-28 -
Commercial Service Date: 11/30/72 Page .16 of 16 ,
Abstract of Conditions Noted / Corrective Measures Taken Section 12/13 ASME Cat item ID Conditions Noted and Corrective Measures Taken F-A H103B Visual examination of H103B revealed a loose reservoir clamp. Work order 93-7932 was issued to tighten the clamp. Follow-up VT-3 was acceptable. This condition was evaluated to
- be insignificant to proper function of the component.'
F-A HD-1078 Visual examination of HD-1078 revealed spring cans to be out of tolerance. Work order 93-7944 was issued to reset the spring can. Follow-up VT-3 was acceptable. This condition was determined to be service related and additional supports, HPCI-HD-84, HD-107A and HD-107C were inspected. HPCI-HD7 84 and HD-107A were found acceptable. HD-107C was found out of tolerance (see additional information below on HD-107C).
F-A HD-107C Visual examination of HD-107C revealed spring cans to be out of tolerance. Work order 93-8206 was issued to reset the spring can. Follow-up VT-3 was acceptable. This condition was determined to be service related and additional supports, HPCI-HD-35C and HD-35D were inspected. HPCI-HD-35C was found acceptable. HD-35D was found out of tolerance (see additional information below on HD-35D).
F-A HD-35D Visual examination of HD-35D revealed spring cans to be out of tolerance. Work order 93-8518 was issued to reset the spring can. Follow-up VT-3 was acceptable. This condition was determined to be service related and additional support, HPCI-H-32 was inspected. HPCI-H-32 was found acceptable. At this point, all double spring can in the HPCI system were examined.
F-A HD103C' Visual examination of HD103C revealed a loose bolt on the pipe clamp. Work order 93-7943 was issued to tighten the bolt. Follow-up VT-3 was acceptable. This condition was evaluated to be insignificant to proper function of the component.
.__m -i.. ___._____i._.___._m_._.'%__.w%-- , _ , , , _ . , -
..,.m , w. .,.- - 34, . , , , ,3. y.., _ . ,..y.# _.. ..._ _y ,.y y , , , . , .