Discusses IE Insp Rept 50-047/74-01.Annual Followup Is Necessary to Resolve Outstanding Items
ML20054C805
Person / Time
Site: 05000047
Issue date: 07/25/1974
From: Plumlee K
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Caphton P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML17298A033 List: ... further results
References
FOIA-81-311, FOIA-Z81-311 NUDOCS 8204210689
Download: ML20054C805 (1)


See also: IR 05000047/1974001

Text

-

- --

.-

. . . . . - .

. . . .

.

.

.

,

-

7

n

.

.

,

JUL 2 51974

.

D. L. Caphton, Senior Reactor Inspector, B'4R and Research Reactors

Section

INSPECTION REPORT NO. 30-47/74-01 .O!MRC

Inspection identified three violations and three unresolved items that

are typical of poor management at AMMRC. No specific hazard to person-

nel was found.

One violation was repetitive in that a citation for violation of TS re-

quirements on cathodic protection was made on the preceding inspection

and again this time.

In view of the 1997 expiration date for License

to minimize

No. R-65, the cathodic protection seems fairly important

below-grade corrosion on the containment shell.

Corrosion is already

extensive.

Dr. Gorum seemed inclined to take reasonable action however, the general

attitude of other personnel is that funding is very tight.

There was talk of changing Technical Specifications' to reduce surveil-

lance requirements, and possibly decommissioning the reactor.

I believe that an annual folicv-up is necessary to get the outstanding

items resolved for this f acility.

(-

/.

o

v $1,

, h(4AkLL

'

Karl E. Plumlee

Reactor Inspector

.

8204210689 811005

PDR FOIA

KABAT-Z81-311

PDR

---

-