NRC F ORM 366 U. S. NUCLE AR REGUL AToRY COMMISSloN (7 771 LICENSEE EVENT REPORT CONTROL BLOCK: l 1

l l l l l 6

lh (PLE ASE PRINT OR TYPE ALL REQUIRED INFoRMATioNI

[7ITl lC lA 15 l0 lS l 3 l@l0 l0 l- 10 14 16 l0101010 LICENSE NUV8ER l- 10 l0 l@26l4l11111l1l@l 25 LICENSE TYPE JO l

67 CAT 66 l@

7 1* 9 UCENSEE CODE con'T

?

o 1 8

[$ l L60}@l 0_ l 5 l0 61 l0 l0 l3 l 6 l2 DOCKET NUV8ER 68 )@l169 lE VENT 211 DATEl0 l812 l@l 0 74 75 l 1 CATE REPORT l 0 l 8 l 8 l 3 l@

DO EVENT DESCRIPTION AND FRoBABLE CONSEQUENCES h 10121 l While in Mode 5, a review of strip chart recordings of the RCS temperatures during i io i3 i i filling and venting operations performed on December 11, 1982, indicated that the I io i4 l l RCS heatup rate had been exceeded. The requirements of the applicable LC0 3.4.8.1 l io is j l indicated that the effects on structural integrity and the fracture toughness margin l l0 je l l were not compromised and normal plant operations could proceed without restriction. l

[TJT] l There was no impact on the health and safety of plant personnel or the public l iO ie i i associated with this event. I 7 8 9 C DE CODE S8 E COMPONENT CODE SUB D'E SU E g I C l E l@ [ Aj@ EJ@ l Z l Z l Z l Z l Z l Z l@ [Z_J@ 18 19

[Z_j 20 7 8 9 30 11 12 13 EVENT YE AR REPORT O C DE N .

@ g(gp on l8l2l [__j l0l0l7l y l0 l3 l N M U30

[--j 31

[0_l 32

_ 21 22 23 24 26 27 ME H HOURS 22 SB t FOR 8. Li R MAN F CTURER T KEN A T ON ON PL NT l0l0l0l l W@ [Njg [Zjg l Z l 9 l 9 l9 lg lH 3J g l34H l g [36Zjg l36Zl@ 37 40 41 42 43 44 57 CAUSE DESCR6PTIC N AND CORRECTIVE ACTIONS h ji iOi l This event was caused by inadequate attention to heatup restrictions. Responsible l

, , l Operations personnel have reviewed the circumstances and have been directed to more l

, 7 l closely monitor the RCS vent and fill' operations and all operations involving RCS I

, l heatup and cooldown. Th'is will be included in their monthly retraining session. l l Additionally, fill and vent procedure 5023-3-1.4 is currently in the revision processI .

l i 4 I to Drovide additional cuidance. 80 i

7 8 9 STA  % POWER OTHER ST ATUS Dis O RY DISCOVERY DESCRIPTION i s

[B_J @ l 0l 01 0l @ l N/A l [Bj@l l ACTIVITY CO TENT AMOUNT OF ACTIVITY LOCATION OF RELEASE RELE ASED OF RE LE ASE i s y @ Wgl N/A l l N/A 80 l

7 8 9 10 11 44 46 PERSONNEL EXPOSURES NUM8ER TVPE 1 7 1010 l0 l@y@ DESCRIPTION N/A l

' eERSONNE t iNaubs NUMB E R DESCRIPTION l

Q l010 7 8 9 l0 l@l it i N/A .

,o T E DE R PT Q (Z_j@l N/A ,

8 l

eueusTy 8301200120 830100 NRC WE ONLY ,

PDR ADOCK 05000362 2 o iSSUEo@DESCR;PT

[Lj l N/A S ON@ PDR l lllllllllllllj N Ave or earpaara H.B. Ray Nb N ,ggyg. ( 14) 492-7700