05000293/LER-1981-031-03, /03L-0:on 810618 & 19,main Stack Sample Pump a Tripped.Caused by Increased Internal Friction

From kanterella
(Redirected from ML20009E801)
Jump to navigation Jump to search
/03L-0:on 810618 & 19,main Stack Sample Pump a Tripped.Caused by Increased Internal Friction
ML20009E801
Person / Time
Site: Pilgrim
Issue date: 07/18/1981
From: Mcloughlin M
BOSTON EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML20009E800 List:
References
LER-81-031-03L, LER-81-31-3L, NUDOCS 8107280459
Download: ML20009E801 (1)


LER-1981-031, /03L-0:on 810618 & 19,main Stack Sample Pump a Tripped.Caused by Increased Internal Friction
Event date:
Report date:
2931981031R03 - NRC Website

text

-

N!1C EORM 366 U. S. NUCLE AR REGULATORY COMMISSION (7-771 LICENSEE EVENT REPORT CONTROL BLOCK: l l

l l

l l

lh (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION) i e

l0 li [ lM l A lP lP IS l 1 l@[ 0l 0l -l Ol 0l 0l 0 l 0 l-l 0 l 0 l@l 4 l 1 l 1 l I l 1 l@l l

l@

7 8 9 LICENSEE CODE 14 15 LICENSE NUMBER 23 26 LICENSE TYPE JO 57 CAT 58 CON'T lL @l015 l0 l-l0 l2 l 913 @l 016 l 1 l 8 l 8 l 1 l@l 0 l 7 l 1 l 8 l 8 l 1 l@

l0l1l SO RC 7

3 6J 61 DOCKET NUM9 ER 68 69 EVENT D ATE 14 75 REPORT DATE 80 EVENT DESCRIP110N AND PROB ABLE CONSEQUENCES h Io l2l [ On June 18, 1981 and again on June 19, 1981, main stack sample pump ' A' tripped.

l 1o i3 l l On both occasions the pump had a blown fuse. The pump was removed from service l

lo la I l for repair and the installed spare pump placed in service.

I l o i s i l_

l 10161 l l

N lCl7ll l

l lo is ! I 80 7

8 9 C DE CODE SUSCO E COVPONENT CODE SL CO D'E SU E

10191 lM lC l@ lE l@ lF l@ l Pl Ul Ml Pl El Xl@ l Hl@ l Zl@

7 8

9 10 11 12 13 18 19 20 SEQUENTI AL OCCURRENCE REPORT REVISION LER RO EVENT YEA R R EPORT NO.

CODE TYPE N O.

@ REP l8l1l l-l l 0 l 3l 1l l/l l0131 lL' l-l l0 l RT

_ 21 22 23 24 26 27 28 29 30 31 32 TA N A N

O PLA T A T HOURS S8 FOR 8.

SUPPLI MANUFACTURER lCl@lZl@

l 7, l@

l Z l@

l 0 l O f 01 0 l l Nl@

lN l@

lL l@

lGl2l0l0l@

JJ 34 35 36 3/

40 41 42 43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h ji jojl Increased internal friction caused by normal wear resulted in blown power supply

[

1, ; ; ; ; fuses. These pumps have a short service lifetime and are rebuilt periodically as

,,,7j l part of a regular preventive maintenance program.

l 11 I 31 l I

l I

l li I A II f

80 7

8 9 ST S

% POWER OTHER STATUS IS O RY DISCOVERY OESCRIPTION Ii I s l l E l@ l 1 l 0 l 0 l@l N.A.

l lA l@l Annunciator Alarm l

80 ACTIVITY CONTENT n

RELEASE AMOUNT OF ACTIVITY LOCATION OF RELEASE Q6) l i l 6 l l Z l @D OF RELEASE @l N.A.

l l

N.A.

l aERSONNEL EXPOSU ES DESCRIPTION @

NuM8eR TYPE N.A.

l l i l 7 l l O l 0 l 0l@l Zl@l

(

  • ER SONN E t\\NJURIES DESCRIPTION @

NUveER N.A.

li 18 l l 0l 0l 0l@l 7

8 9 11 12 80 LOSS OF OR DAMAGE TO FACILtTY TYPE

DESCRIPTION

a l i l 9 l l Z l@l N.A.

l 7

8 9 10 80 ISSUE @ DESCRIPTION l

N.A.

l lillIlllll lll5 12lol 68 69 80 3 7

8 9 to 8107280459 810718 M. Thomas McLoughlin 617-746-7900 o

PDR ADOCK 05000293 PHONE: