05000325/LER-1980-074-03, /03L-0:on 800914,during Performance of Primary Containment Leak Rate Testing,Inner Airlock Door Seals Would Not Hold Required Pressure for Specified Time.Caused by Slight Door Misalignment.Door Strongbacks Installed

From kanterella
(Redirected from ML19347B669)
Jump to navigation Jump to search
/03L-0:on 800914,during Performance of Primary Containment Leak Rate Testing,Inner Airlock Door Seals Would Not Hold Required Pressure for Specified Time.Caused by Slight Door Misalignment.Door Strongbacks Installed
ML19347B669
Person / Time
Site: Brunswick 
Issue date: 10/07/1980
From: Tollison A
CAROLINA POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19347B656 List:
References
LER-80-074-03L, LER-80-74-3L, NUDOCS 8010150529
Download: ML19347B669 (1)


LER-1980-074, /03L-0:on 800914,during Performance of Primary Containment Leak Rate Testing,Inner Airlock Door Seals Would Not Hold Required Pressure for Specified Time.Caused by Slight Door Misalignment.Door Strongbacks Installed
Event date:
Report date:
3251980074R03 - NRC Website

text

U. S. NUCLE AR REOULAVL@JV L@wMW NRC FORM 66

.7 77).

.P LICENSEE EVENT REPORT fs

.U CcNinOL STOCK: l l

l-. l l

l l@

(PLEASE PalNT OR TYPE ALL ACQUIRED INf'ORMAtl0NI I

6 lo l1l l Nl Cl Bl El Pl 1l@l 0 l 0l -l 0 ] 0 l 0 l 0 l 0 l - l b l 0 l@l 4 l 1 l l l 1 l 1 l@l l

l@

I 8 7 LlOLNSEE LODL 14 15 LICENSL JsVMULH

.' 5 2G LICENSE TYPE JJ

$7 LAI kJ CON'T lolil 3g, l L@l 0l 5l 0l -l 0l 3l 2 l 5 @l 0 l 91 I l 4 l8l0l@l110l0l718IOj@

i 8

LO b1 DQGK ET NUYD ER t.d 63 LVENT DATE 44 75 nESCAT DATE CJ EVENT DESCRIPTION AND PROBA0LE CONSECUENCES h I

10(2l l During the perfortance of PT 2.6.5P, Primarv Containment Lenk Rate Testing on the it was l

[ol3l l personnel interior and exterior doors, follouing a drvwell entry at power.

I o I.: l l found that the inner airlock door seals would not hold the recuired pressure for the I l o I s l I specified length of time. This event did not affect the health or safety of I

I Iois1 I the public.

l l o 17 l l Lo_i s,I I Technical Specifications 3.6.1.3. 6.9.1.9b I

80 7

8 9 DE COCF SU3CO E COV.PONENT CODE SLeC dE S

OE 19191 i s lo l@ Lej@ l 81@ I P j e l N j e I T l a l@ l Al@ i Zl @

7 8

9 10 11 12 13 18 IJ 2;

SEQUENTI AL OCCUR 9ENCC REPORT REVISION (g g rpo EVENT YEAR A EPORT No.

CCOE TYPE No.

l8l0l l-l l0l7l4l l/l l0 l3 l l Ll l-l l0 l O17RE R 2,

n n

u u

27 u

n u

2, 22 K r C

oNPLANT T

FOUnS 22 SB IT F

1 8.

S FPLIE M N FA REn l Xl@l Xl@

l Z l@

l Z l@

l0l0l0j0l l N lg l2Ylg lNlg lCl3l1l0lg 34 J5 36 3,

40 41 4

43 44 47 34 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h Ii)oj l Aa investigation revealed that slight door misalignment prevented the door seal from l

j Iiti; y making proper contact with the sealing surfaces of the airlock.

The door strongbacks l-i l were installed to fully seat the door seals and the PT was suCcessfully completed.

1

,,;7j Ii13i l *1he outer airlock door was checked and found satisfactory.

The inner door will be l

li14l l inspected and repaired as necessary during the next available outage.

l 80 I

B 9 5TA S

% POWER OTHER ST ATUS DISC RY DISCOVERY OESCPtPTiON I1iSllCl@ l0lIl1l@l NA l

l B l@l Periodic Test l

80 ACTIVI TY Co TENT aELEAsto CF RELEASE AYoVNT OF ACTIVtTY LOCATION OF RELEASE NA l

l NA l

[ITllzl@ lZl@l 44 45 gg 7

8 9 10 11 PEnSONNEL FtPOSunES NW81H TYPE DESCRIPT10N -

l I i I 7 I I o l 0 I o l@l Z l@l NA So PE ns CNNE L,N,u'iES nESCn PnON@

Nw8E n NA l

l i 12 1lolol01@l go 7

f4 - 9 11 12 O

A Q

g

^

toS5 9F Ott DWAGE TO FACILITY g I

l1 TYPE Ot hCillPit0N L,LL11 L,J2J81 NA ko o

t

,o

,o NRC USf ONLY NA i

,,, i i, i,;;,, ig ggpsemP""

6310150 E R q s

oo.g a o in

~-

g