Jump to navigation Jump to search
LER 80-035/03L-0:on 800625,during Regeneration of Condensate Polisher Resin,Waste Water Discharged Into Liquid Effluent Sys.Caused by Failure of Beckman Conductivity Cell.Cell Replaced & Discharge Valve Operability Verified
ML19344E049
Person / Time
Site: Fort Saint Vrain Xcel Energy icon.png
Issue date: 07/25/1980
From: Gahm J
PUBLIC SERVICE CO. OF COLORADO
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
Shared Package
ML19344E046 List:
References
LER-80-035-03L, LER-80-35-3L, NUDOCS 8008260552
Download: ML19344E049 (5)


Text

. . .

NR M 366 U. S. NUCLE AR f!EGULATORY COMMISSION (7

LICENSEE EVENT REPORT CONTROL SLOCK: l 1

l l  ! I I 6

lh (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION)

Io IiI8 l9CI eIUCENSEE FI sCODE I vi 1l@l o I o I I o IUCENSE o I oNuM8ER I o I o I _ l o I o2Sl@l266 I 3UCENSE I 3 I TYPE o I oJOl@l57 CAT l 68 Ig

? 14 15 CON'T lolil 8

SsRCE 60 I Li@l 61 o f 510101 COCK ET NUMBER o f 216 I6871@l 69 016 l 2151810 l@l EVENT DATE F4 75 017 l 2151810 REPORT C ATE 80l@ .

EVENT DESCRIPTION AND PROSABLE CONSEQUENCES h l o l 21 l I.'hile operating at approximately 5% thermal power, curing regeneration a batch of con-i I

Io I3I i densate polisher resin, waste water was discharged to the plant liquid effluent sys- I lo lai i tect rather than the waste neutraliqing tank. As a result. Ifmits for Cu_ '7 n . w r4 W l I o ! 5 ! ; were exceeded. Degraded mode of LCO NR 1.1. Reportabla per AC 7.5.2(b)2. No affect l l o 16 l l On Dublic health or safety. Nc simi3nr nee'tr*pnepe- I l o 171 I l I

lotall 80 7 8 9 SYSTEM CAuSE CAuSE COMP. VALVE CODE CCOE SuSCOCE COMPONENT CODE Su8C00E SuBCOCE lo49l 7 8 l Xl X]h 9 10 11 h l'F l h i Il NI Sl Tl RI Ul h l El h l Zl h 12 13 18 19 20 SEO JENTI A L OCCURRENCE REPORT R EVISION (gm Ro EVENT YEAR REPesT NO. CODE TvPE N O.

O RE y

" 1810 l l-l 10l3l5l l/l lo 13 l lLl l-l 10 l

_ 21 22 23 24 26 27 3 3 30 31 32 TAK N AC CN O PL ANT VE MouRS S8 i SOR 8. S Pet E MANLFAC RER IAl@lZl@

33 34 l Zl@

35 lZlh 36 l0l0l0101 3/ 40 LIJ@

41 LaJ@

42 IN 43 i@ 18 li l 31 s47l@

44 CAUSE DESCAIPTION AND CORRECTIVE ACTIONS t i l o l l A failed Beck =an conductivity cell controlling the discharze valves for the recenera- 1

[,,,j l tion system caused waste water to be released to the building liquid effluent. The 1

,,,,,  ; cell was replaced and discharge valve operability was verified. I I

t i l 31 I l

I 11 tali 7 a 3 80

'IN ST  % *CWEP' OTHER STATUS I C y DISCOVERY OESCRtPTION I

l2 i5I* l El h IO l0 15 'l h lN/A l l B lhl Routine Chemical Analvsis '

ACTiviTv CC'NTENT REuASE TOC 2 Tion o, REuASE @

l i 161 L2J @o C,REuASEL-J@lx/4 AyouNT e, ACTiviTv @ Iv/s I I

.ER$c~NEL Ex,cSSES NuM8ER ESCRiPTic~@

l i l 71 l o f 0 ! o l@l2 TvP,@ll N/A I

' ' ' ' 2 i2 80

,E RS ON N E c'iN2u'R ,,,

l NuM8ER cESCRiPTiCN@

l lililIololol@lN/A 7 8 9 11 12 80 l

l '. CSS C, CR QAMAGE TO FAC1UTV 43 i

TYPE D E SCRIPTION l li 191 Lsj@l N/A I I

iS$uEO ususrv DESCR19 TION N s,/

n 552_

t NRC uSe ONLv 8 8008280 l l 21 o l LyJ@l N/A i i i i iiiiiiiiili

. .. . . . N/ ~m,,. ( O ') 785-2253