05000293/LER-1980-039, Forwards LER 80-039/01T-0

From kanterella
(Redirected from ML19331D802)
Jump to navigation Jump to search
Forwards LER 80-039/01T-0
ML19331D802
Person / Time
Site: Pilgrim
Issue date: 08/29/1980
From: Mcguire P
BOSTON EDISON CO.
To: Grier B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML19331D803 List:
References
80-201, NUDOCS 8009030596
Download: ML19331D802 (1)


LER-1980-039, Forwards LER 80-039/01T-0
Event date:
Report date:
2931980039R00 - NRC Website

text

ec ms Edison uum, r

PILCRIM NUCLEAR PCWER STATION RFD *1 ROO<Y HILL 4GAO P LY M O UT H, M A534CMcGCTT3 Cc36C August 29, 1980 BECo Ltr. #80-201 Director, Region I Office of Inspection and Enforcement U. S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, PA 19406 Licensee Event Report 80-039/01T-0 Docket Number 50-293 License DPR-35 Gentlemen:

The attached L*lcensee Event Report 80-039/01T-0, "APRM Scram Setpoint", is hereby submitted in accordance with the requirements of Pilgrim Nuclear Power Station Technical Specificatior. 6.9.B.1.f.

If there are any questions on this subject, please contact us.

Respectfully submitted, P. J. McGuire Station Manager Nuclear 7perations MTM:ep

Enclosures:

(3 copies)

LER 80-039/01T-0 cc: Director (40 copies)

Office of Management Information and Program Control U. S. Nuclear Regulatory Commission Jashington, D.C.

20555 i

l l

l b

8009030