05000325/LER-1980-053-03, /03L-0:on 800607,during Normal Reactor Bldg Tour During Refueling,Inner & Outer Doors of 50-ft Air Lock Found Open.Caused by Burned Coil in Inner Door Interlock Solenoid. Coil Replaced & Air Lock Access Restored

From kanterella
(Redirected from ML19320C031)
Jump to navigation Jump to search
/03L-0:on 800607,during Normal Reactor Bldg Tour During Refueling,Inner & Outer Doors of 50-ft Air Lock Found Open.Caused by Burned Coil in Inner Door Interlock Solenoid. Coil Replaced & Air Lock Access Restored
ML19320C031
Person / Time
Site: Brunswick 
Issue date: 07/11/1980
From: Tollison A
CAROLINA POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19320C021 List:
References
LER-80-053-03L, LER-80-53-3L, NUDOCS 8007150665
Download: ML19320C031 (1)


LER-1980-053, /03L-0:on 800607,during Normal Reactor Bldg Tour During Refueling,Inner & Outer Doors of 50-ft Air Lock Found Open.Caused by Burned Coil in Inner Door Interlock Solenoid. Coil Replaced & Air Lock Access Restored
Event date:
Report date:
3251980053R03 - NRC Website

text

_

.nm-LICENSEE EVENT REPORT g

CbNYROL BLOCK: (

l l

l l

l lh (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION) 1 6

l N l C l B l E l P l 1 lgl150 l 0 l - l 0 l 0 l 0 l 0 l 0 l-l 0 l 0 l@l 4 l1 l 1 l 1 l 1 l@l lj@

o i 9

LICENSEE CODE 14 LICENSE NUMSLR 26 26 LICENSE TYPE JO 57 CAT $8 2

8 CONT M l L l@l 0 l 5 l 0 l - l 0 l 3 l 2 l 5 l@l 0161017 l 810 @l 0 l 7 l1 l 1 l 8 l 0 l@

o i i

8 60 61 DOCKET NUMSER 68 63 EVENT OATE 74 75 REPORT O ATE 80 EVENT DESCRIPTION AND PROSA8LE CONSEQUENCES h F

o 2 1 During a normal tour of the Reactor Building during a refueling outage, the I

rasa 1 auxiliary operator found both the inner and outer doors of the 50' elevation l

gl air lock open. The outer door was immediately cicaed, and Security personnel I

pl were stationed at the air lock to prevent the opening of the outer door.

CRD l

o s l rebuilding was in progress at the time.

l 0 7 l l

gpi1 l Technical Specifications 3.6.5.1, 6.9.1.9b I

7 8 9 C E ODE SU C E COMPONENT COCE OUS ode SU E

Q l Sl Al@ W@ l A l@ lI lN lS lT [R lU l@ lE l@ lZ l@

7 8

9 10 11 12 13 18 19 20 SEQUENTIAL OCCURRENCE REPORT REVISION LE R/Ro EVENT YE AR REPORT No.

Co0E TYPE No.

@,RE l 8l 0l l-l 10l 5l 3l l/l l0l31 lL l

(--j W

21 22 23 24 26 27 28 29 30 31 32 KN A O O P NT M

HOURS 22 S8 i FC S.

S PPLIE MA UFACTURER l Al@l Zl@

lZl@

l Z IQ l 0 l0 l 0 l 0 l l Nl@

l Ni@

l A l@

lX l9 l9 l9 l@

j 33 34 3$

36 37 40 41 42 43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h g,,o,j The inner door interlock solenoid which prevents both doors from opening simul-I taneous had a burned coil. The coil was replaced and access to the air lock was l

g returned. No reaso t could be determined for the coil burnout. This is considered l

,, y

, 3 l an isolated event and no further action is required.

l i 4 1

i

.7 8 9 80

'SYA

% POWER CTHER STATUS I

Y DISCOVERY DESCRIPTION l Hl@ l0 l 0 l0 l@l N/A l

l A l@l Operator Survt 111ance I

i s AETiviTY CONTENT AMoVNToF ACTIVITY @ l LOCATION oF RELEASE @

l P.ELEASE@D CP RELEASE (-j@l l

N/A l

N/A l

W t s 1

8 9 to si 44 4s So PERSONNEL EXPOSURES NUV8ER TYPE

DESCRIPTION

lOl0l0l@ W @l N/A l

1 7 l

i IES PER$oNNEL tNJU oESCRiPTioNQ l

NuMSER l0l0l0l@l N/A l

i H t

8 s is i

So LOSS oF oR DAMAGE To FACIL 7 Q TYPE DESCRIPTio*4 V

W@l N/A l

9 PU8Lif: TY 800715of g NRc i,sE oNLy ISSUED @ DESCRIPTION LN_j l

N/A l

l l l l l l l l ! I l' l l %}

y 2 o F

8 9 to 68 69 80= %

A. C. To111 son, Jr.

919-457-9521 o

NAME OF PREPARER PHONE: