05000293/LER-1980-025-03, /03L-0:on 800602,fire Detection Alarm from HPCI Quadrant Sounded in Control Room on Panel C-94.Roving Fire Patrol Initiated & Immediate Investigation Conducted.Caused by Leak at Flange on HPCI Drain Line Valve AO2301-29

From kanterella
(Redirected from ML19320A900)
Jump to navigation Jump to search
/03L-0:on 800602,fire Detection Alarm from HPCI Quadrant Sounded in Control Room on Panel C-94.Roving Fire Patrol Initiated & Immediate Investigation Conducted.Caused by Leak at Flange on HPCI Drain Line Valve AO2301-29
ML19320A900
Person / Time
Site: Pilgrim
Issue date: 07/01/1980
From: Whitney G
BOSTON EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML19320A893 List:
References
LER-80-025-03L, LER-80-25-3L, NUDOCS 8007080192
Download: ML19320A900 (1)


LER-1980-025, /03L-0:on 800602,fire Detection Alarm from HPCI Quadrant Sounded in Control Room on Panel C-94.Roving Fire Patrol Initiated & Immediate Investigation Conducted.Caused by Leak at Flange on HPCI Drain Line Valve AO2301-29
Event date:
Report date:
2931980025R03 - NRC Website

text

m (7 77)

LICENSEE EVENT REPORT j

' gCONTROL BLOCK:l l

l l

l (PLEATE PRINT OR TYPE ALL REQUIRED INFORMATION) l0 l1l l Ml Al Pl Pl Sl 1l@l 0 l 0 l -l 0 l 0 l 0 l 0 l 0 l - l 0 l 0 l@26l4l1l1l1l1l@l l

l@

7 8 9 LICENSEE CODE 14 15 LICENSE NUM8ER 25 LICENSE TYPE JO 57 CAT 58 CON'T l L]@l 0l 5 l 0 l -l 0 l 2 l 9 l 3 @l 0 l 6 l 0 l 2 l 8 l 0 l@l 017 l 0 l 118 l 0 l@

FE o RC 7

8 60 61 DOCKET NUMBER 68 69 EVENT DATE 74 75 REPORT DATE 80 EVENT OESCRIPTION AND PROBABLE CONSEQUENCES h [ol2l l On June 2, 1980, a fire detection alarm from the HPCI Quadrant sounded in the l

Control Room on Panel C-94.

A roving fire patrol was initiated and an inanediate l

lo lal I lo ;4 ; l investigation conducted.

l 10 I s l l l

10161 l l

10171 l I

10181 1 I

80 7

8 9 E

CODE SUSC E COMPONENT CODE SU8 CODE SU E

y

'l Al Bl@ W@ l Z l@ l Il Nl Sl Tl Rl Ul@ l El@ l Zlh 7

8 9

10 11 12 13 18 19 20 SEQUENTIAL OCCURRENCE REPORT REVISION LE R, RO EVENT YE AR REPORT NO.

CODE TYPE NO.

@ yV aE l8 l0 l l-l l0 l2 l5 l l/l l 0l 3l lLl l-l l0 l

_ 21 22 23 24 26 27 28 29 30 31 32 KN AC ONP NT ME HOURS S8 i FOR 8.

SUPPLI MANUF CTURER W @lZl@

W@

lZl@

l0l0l0l0l lN l@

lN l@

l A l@

lP l 4l 3l 5l@

33 34 35 36 31 40 41 42 43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS liloi L Investigation determined that a leak at the flange on the HPCI drain line valve l

gl (A0 2301-29) had set off the detector. HPCI drain line valve was fixed and I

detector checked out 0.K.

l gl Lu.3J l I

EI l

7 8 9 80 STA

% POWER OTHER STATUS IS O RY DISCOVERY DESCRIPTION g W @ l 0l 8lOl@l N.A.

l lAl@l Operational Event l

A TlVITY CO TENT AMOUNT OF ACTIVITY LOCATION OF RELEASE r.ELEASE@D OF RELEASE @l N.A.

l l

N.A.

l 1 6 7

8 9 10 11 44 45 80 PERSONNEL EXPOSURES NUMBER TYPE

DESCRIPTION

l0l0l0l@ [ @l N.A.

l 1 7 PERSONNE L INJU lES NUM8ER

DESCRIPTION

l 0 l O l O l@l N.A.

l 1 a l 7 8 9 11 12 80 LOSS OF OR DAMAGE TO FACILITY TYPE

DESCRIPTION

N.A.

l LZj@l i o 7-8 9 10 80 gh OE CRIPTION 13SUEf@l ROO N.A.

l lllllllllllll$

LN_

2 O 7

8 9 10 -

68 69 80 ;

617-746-7900 2

ney PHONE:

NAME OF PREPARER