05000293/LER-1979-003-03, /03L-0 on 790114:during Control Rod Exercise Surveillance,Control Rod 30-15 Would Not Respond to Insert Signal.Caused by Slight Indentations on Teflon Discs of All Four Directional Control Valve Moveable Cores

From kanterella
(Redirected from ML19269C886)
Jump to navigation Jump to search
/03L-0 on 790114:during Control Rod Exercise Surveillance,Control Rod 30-15 Would Not Respond to Insert Signal.Caused by Slight Indentations on Teflon Discs of All Four Directional Control Valve Moveable Cores
ML19269C886
Person / Time
Site: Pilgrim
Issue date: 02/12/1979
From: Mathis C
BOSTON EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML19269C885 List:
References
LER-79-003-03L, LER-79-3-3L, NUDOCS 7902200036
Download: ML19269C886 (1)


LER-1979-003, /03L-0 on 790114:during Control Rod Exercise Surveillance,Control Rod 30-15 Would Not Respond to Insert Signal.Caused by Slight Indentations on Teflon Discs of All Four Directional Control Valve Moveable Cores
Event date:
Report date:
2931979003R03 - NRC Website

text

.

7 77)

LICENSEE EVENT REPORT CONTROL BLOCK: l l

l l

l l

h (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATioN) 1 6

g lM l A P l P l S l 1 lgl 0 l0 l 0 l 0 0 [0 l0 l0 l0 0l0lgl4 l1 l1 l1 l1 gl lg 8 9 LICENSEE CODE 14 lb LICENSE NUMUEH 2b 26 LICENSE TYPE JO bl LAIbd CON'T 3{gcg l L l@l 0 l 5 l 0 l - l 0 l 2 l 9 l 3 @l 0 l 1 l1 l4 l 7 l9 l@l012 l1 l 2 l 7 l9 l@

o i

8 60 61 DOCK ET NUMBE R bd 63 EVENT DATE I4 75 PEPORT DAT E 80 EVENT DESCRIPTION AND PROBABLE CONSEQUENCES h o 2 l On January 14, 1979, while performing control. rod exercise surveillance 8.1.2, con-o 3 l trol rod 30-15 would not respond to an insert signal. Technical Specification l

o 4

l 3.3.A.2.a requires that control rods must have the ability to be moved with control j o., l rod drive pressure. The CRD was declared inoperable and isolated for repairs. No

]

lo is l l other drives were inoperable therefore, shutdown capability was maintained.

l 0

7 l

l 0

8 i

l 7'

8 9 80 DE CODE SUBCO E COMPONENT CODE SU8 CODE SU E

lR lB lh yh Wh VlAlLlVlElXlh W h (_G_jh O

9 7

8 9

10 11 12 13 18 19 20 SEQUENTIAL OCCURRENCE REPORT REVISION LER Ro EVENTVEAR REPORT NO.

CODE TYPE N O.

.h REPORT l7 9l l_l l 0 l 0l 3l

]/l l0l3l lL l_l 0l

_ 21 22 23 24 26 27 28 23 30 31 32 K N AC ON O PL T FTH HOURS S 8 IT D FOR 5 9.

'iA FA T RER lAl@lZl@

l Z l@

l Z l@

l 0 l 0l 0 0]

l Nl@

l N @, SUPPLIERNl@

l Al 4 9l9l@

33 34 35 36 31 40 41 42 43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS 27 l Investigation revealed slight indentations on the teflon discs of all four 3

o

,,,,, l directional control valve moveable cores. The cores were replaced in kind and CRD l

,, g ; 30-15 exercised satisfactorily, verifying that control rod drive collet housing g,g3; l failure had not occurred.

l L'_.l.a I I l

7 8 9 80 ST S

% POWER OTHER STATUS dis OV RY DISCOVERY DESCRIPTION ITTil 6@ l 11 IOl@l N.A.

l lBlgl Routine Surveillance l

ACTIVITY CON TE NT RELEASED OF RELEASE AMOUNT OF ACTIVITY LOCATION OF RELEASE hIZl@l N.A.

l l

N.A.

l 1

6 7

8 9 10 11 44 4S 80 PERSONNEL EXPOSURES NUMRER TYPE

DESCRIPTION

y l 0l 0l 0l@ l Zl@l N.A.

l PERSONNE t INJURIES NUMAER

DESCRIPTION

l0 0l 0l@l N.A.

l i R 7

8 9 11 12 80 LOSS OF OR DAMAGE TO FACILITY TYPE

DESCRIPTION

] @l N.A.

l 9

7 8 9 10 80 iSSui'@L'SCniPTiON @

7902*0000 E

~

[_NJ l

N.A.

l lllllllllllll2 2 o 7

8 9 lu 68 60 H0 5 Charles J. Mathis 617-746-7900 o

NAME OF PREPARER PHONE: