Text

[

UNITED STATES yg

/.

NUCLEAR REGULATORY COMMISSION

$. I. '.[d I WASHINGTON, O C. 20555

'o2N2.!P/E W

January 26, 1979

,o Docket No: 50-500 and 50-501 Mr. Lowell E. Roe Vice President, Facilities Development The Toledo Edison Company Edison Plaza 300 Madison Avenue Toledo, Ohio 43652

Dear Mr. Roe:

SUBJECT:

INFORMATION RELATING TO CATEGORIZATION OF RECENT REGULATORY GUIDES BY THE REGULATORY REQUIREMENTS REVIEW COMMITTEE -

(Davis Besse Nuclear Power Station, Units 2 and 3)

We have recently advised utilities with plants in the post-CP phase of the reactor licensing process of the status of NRC staff review and use of recently-approved regulatory guides, and have indicated how these guides would be used in the Operating License review of their Final Safety Analysis Reports. Such information, while not directly applicable to you at this time, may nonetheless be useful to you for your future planning. The text of our letter to these utilities is the following:

"SUBJ ECT:

IMPLEMENTATION OF STAFF REVIEW REQUIREMENTS - (Name of Plant) - OPERATING LICENSE REVIEW During the last several years, we have reviewed and approved several new regulatory guides and branch technical positions or other modifications to existing staff positions. Our practice is that substantive changes in staff positions be considered by the NRC's Regulatory Requirements Review Committee (RRRC) which then recommends a course of action to the Director, Office of Nuclear Reactor Regulation (NRR). The recommended action includes an implementation schedule. The Director's approval then is used by the NRR staff as review guidance on individual licensing matters.

Some of these actions will affect your application.

This letter is intended to bring you up to date on these changes in staff positions so that you may consider them in your Final Safety Analysis Report (FSAR) preparation.

790214000(

i

Mr. Lowell E. Roe.

"The RRRC applies a categorization nomenclature to each of its actions.

(A copy of the sunmary of RRRC Meeting No. 31 concerning this categorization is attached as Enclosure 1.) Category 1 matters are those to be applied to applications in accordance with the implementation section of the published guide. We have enclosed lists of actions which are either Category 2 or Category 3, which are defined as follows:

Category 2: A new position whose applicability is to be determined on a case-by-case basis.

You should describe the extent to which your design conforms, or you should describe an acceptable alternate, or you should demonstrate why conformance is not necessary.

Ca.egory 3: Conformance or an acceptable alternative is required.

If you do not conform, or do not have an acceptable alternate, then staff-approved design revisions will be required.

"We believe that providing you with a list of the Category 2 and 3 matters approved to date will be useful in your FSAR preparation, and they will be an essential part of our operating license review. is a list of the Category 2 matters. Enclosure 3 is a list of the Catetery 3 matters.

"In addition to the RRRC categories, there also exists an NRR Category 4 list which are those matters not yet reviewed by the RRRC, but which the Director, NRR, has deemed to have sufficient attributes to warrant their being addressed and considered in ongoing reviews.

These matters will be treated like Category 2 matters until such time as they are reviewed by the RRRC, and a definite implementation program is developed. A current list of Category 4 matters is attached (Enclosure 4).

These also should be considered in your FSAR.

"In some instances the items in the enclosures may not be applicable to your application. Also, we recognize that your application may, in some instances, already conform to the stated staff positions.

In your FSAR you should note such compliance.

"If you have any questions please let us know."

Mr. Lowell E. Roe For your information, I am enclosing a set of the enclosures that accompanied these individual letters. These enclosures list the present Category 1-4 matters discussed in the letter.

Sincerely, I

Roger S. Bo

, Director Division of Project thmo9ement Office of Nuclear Reactor Regulation

Enclosures:

As stated cc:

See next page e

!!r. Lowell E. Roe cc:

Mr. Lowell E. Roe Vice President, Facilities Cevelopment The Toledo Edison Company Edison Plaza 300 Madison Avenue Toledo, Ohio 43652 Bruce Churchill, Esq.

Ernest L. Blake, Jr., Esq.

Shaw, Pittman, Potts & Trowbridge 1800 M Street, N. W.

Washington, D. C.

20036 Edward Luton, Esq., Chairman Atomic Safety and Licensing Board U. S. Nuclear Regulatory Commission Washington, D. C.

20555 Dr. David L. Hetrick Professor of Nuclear Engineering The University of Arizona Tucson, Arizona 87521 Dr. Cadet H. Hand, Jr.

Bodega Marine Laboratory University of California P. O. Box 247 Bodega Bay, California 94923

J S

UNITED STATES NUCLEAR REGULATORY COMMisS..

W ASHINGTON. D. C. 20555 SEP 2 41975 Lee V. Gossick

. Executive Director for Operations REGULATORY REQUIREl1Ef4TS REVIEW COMMITTEE MEETIrlG fi0. 31, JULY 11, 1975 1.

The Committee discussed issues related to the implementation of Regulatory Guides on existing plants and the concerns expressed in the June 24, 1974 memorandum, A. Giambusso to E. G. Case, subject: REGULATORY GUIDE li PLEllE!!TATION, and made the following reconmendations and observations:

Approval of new Regulatory Guides and approval of revisions a.

of existing guides should move forward expeditiously in order that the provisions of these regulatory guides be available for use as soon as possible in on-going or future staff reviews of license applications.

The Committee noted that over the recent past, the approval of proposed regulatory guides whose content is acceptable for these purposes has experienced significant delays in RPRC review pending the determination of the applicability of the guide to existing plants, often requiring significant staff effort.

To avoid these delays, the Cocuittee concluded that, henceforth, approval of proposed regulatory guides should be uncoupled from the consideration of their backfit applicability.

b.

The implementation section of new regulatory' guides should address, in general, only the applicability of the guide to applications in tne licensing review process using, in so far as possible, a standard approach of applying the guide to those applications docketed 8 months after the issuance date of the guide for comment.

Exceptions to this general approach will be handled on a case-by-case basis, The regulatory position of each approved proposed guide (or c.

proposed guide revision) will be characterized by the Committee as to its backfitting pot'ential, by placing it in one of three categories:

Category 1 - Clearly fonvard fit only.

tio further staff consideration of possible backfitting is required.

ENCLOSURE 1

Lee V. Gossick _ Category 2 - Further staff consideration of the need for back-fitting appears to be required for certain identified items of the regulatory position--these individual issues are such that existing plants need to be evaluated to determine their status with regard to these safety issues in order to determine the need for backfitting.

Category 3 - Clearly backfit.

Existing plants should be evaluated to determine whether identified items of the regulatory position are resolved in accordance with the guide or by some equivalent alternative.

From time to time, for a specific guide, there will probably be some variation among these categories or even within a category, and these three broad category characterizations will be qualified as required to meet a particular situation.

d.

It is not intended that the Committee categorization appear in the guide itself.

The purpose of the categorization is to indicate those iters cf the regulatory position for which the Committee can make a specific backfit recommendation without additional staff work (Categories 1 and 3), and to indicate those items for which additional staff work is required in order to determine backfit considerations (Category 2).

e.

The Cornnittee recommends that for approved guides in Category 2, staff efforts be initiated in parallel with the process leading to publication of the guide in order that specific backfit requirements for existing plants be determined within a reasonable period of time after publication of the guide, f.

The Committee observed that more attention needs to be given to the identification of acceptable alternatives to the positions outlined in the guides in order to provide additional options and flexibility to applicants and licensees, with the possible benefits of additional innovation and exploration in the solution of safety issues.

2.

The Committee reviewed the proposed Regulatory Guide 1.XX: THERMAL OVERLOAD PROTECTION FOR MOTORS OF MOTOR-0PERATED VALVES and recommended approval.

This guide was characterized by the Committee as Category 1 - no backfitting, with the stipulation that as an appropriate occasion presented itself in conjunction with the review of some particular aspect of existing plants, the i.hermal overload protection provisions be audited.

ENCLOSURE 1 (CONT'D)

Lee V. Gossick 3.

The Comnittee reviewed the proposed Regulatory Guide 1.XX:

INSTRUiENT SPANS AtiD SETPOIflTS and reconnended approval subject to the following comment:

Paragraph 5 of Section C (page 4 of the proposed Guide) should be reworded in light of Committee comments, to the satisfaction of the Director, Office of Standards Developnent.

This guide was characterized by the Comnittee as Category 1 - no backfit.

4.

The Connittee re iewed Proposed Regulatory Guide 1.97:

INSTRU:'.EilTATIO ! FOR LIGHT '.!ATER COOLED t'UCLEAR PO'.lER PLA!'TS TO ASSESS PLANT CO:iDITIONS DU?.It'G AND FOLLO'.11t'G AN ACCIDENT and deferred further consideration to a later meeting in order to permit incorporation of recent corments by the Division of Technical Review.

/

Edson G.

ase, Chairnan Regulatory Requirements Review Committee ENCLOSURE 1 (CONT'D)

e g

September 15, 1978 CATEGOPY 2 MATTERS Document Number Revision Date Title RG 1.27 2

1/76 Ultimate Heat Sink for Nuclear Power Plants RG 1.52 1

7/76 Design, Testing, and Maintenance Criteria for Engineered-S..fety-Feature Atmosphere Cleanup System Air Filtration and Adsorption Units of Light Water Cooled Nuclear Power Plants (Revision 2 has been published but the changes from Revision 1 to Revision 2 may, but need not, be considered.

RG 1.59 2

8/77 Design Basis Floods for Nuclear Power Plants RG 1.63 2

7/78 Electric Penetration Assemblies in Containment Structures for Light Water Cooled Nuclear Power Plants RG 1.91 1

2/78 Evaluation of Explosions Postulated to Occur on Transportation Routes Near Nuclear Power Plant Sites RG 1.102 1

9/76 Flood Protection for Nuclear Power Plants RG 1.105 1

11/76 Instrument Setpoints RG l.108 1

8/77, Periodic Testing of Diesel Generator Units Used as Onsite Electric Power Systems at Nuclear Power Plants RG 1.115 1

7/77 Protection Against Low-Trajectory Turbine Missiles RG 1.117 1

4/78 Tornado Design Classification RG 1.124 1

1/78 Service Limits and Loading Combinations for Class 1 Linear Type Component Supports RG 1.130 0

7/77 Design Limits and Loading Combinations for Class 1 Plate-and Shell-Type Component Supports (Continued)

ENCLOSURE 2

CATEGORY 2 MATTERS (CONT'D)

Continued Document Number Revision Date Title RG 1.137 0

1/78 Fuel Oil Systems for Standby Diesel Generators (Paragraph C.2)

RG 8.8 2

3/77 Information Relevant to Ensuring that Occupational Radiation Exposures at Nuclear Power Stations Will be as Low as is Reasonably Achievable (Nuclear Power Reactors)

Guidelines for Fire Protection for BTP ASB 9.5-1 1

Nuclear Power Plants (See Implemeritation Section, Section D)

BTP MTEB 5-7 4/77 Material Selection and Processing Guidelines for BWR Coolant Pressure Boundary Piping RG 1.141 0

4/78 Containment Isolation Provisions for Fluid Systems ENCLOSURE 2 (CONT ' D)

September 15, 1978 CATEGORY 3 MATTERS Document Nuinber Revision Date Title RG 1.99 1

4/77 Effects of Residual Elements on Predicted Radiation Damage to Reactor Vessel Materials (Paragraphs C.1 and C.2.

RG 1.101 1

3/77 Emergency Planning'for Nuclear Power Plants RG 1.114 1

11/76 Guidance on Being Operator at the Controls of a Nuclear Power Plant RG 1.121 0

8/76 Bases for Plugging Degraded PWR Steam Generator Tubes RG 1.127 1

3/73 Inspection of Water-Control Structures Associated with Nuclear Power Plants RSB 5-1 1

1/78 Branch Technical Position: Design Require-ments of the Residual Heat Removal System R58 S-2 0

3/78 Branch Technical Position:

Reactor Coolant System Overpressurization Protection (Draft copy attached)

RG 1.97 1

8/77 Instrumentation for Light Water Cooled Nuclear Power Plants to Assess Plant Conditions During and following an Accident (Paragraph C.3 - with additional guidance on paragraph C.3.d to be provided later)

RG 1.68.2 1

//78 Initial Startup Test Program to Demonstrate Remote Shutdown Capability for Water-Cooled Nuclear Power Plants RG l.56 1

7/78 Maintenance of Water Purity in Boiling Water Reactors Attachment; BTP RSB 5-2 (Oraft)

ENCLOSURE 3

~

DMFT BRAriCH TECHillCAL POSIT 10:1 R58 5-2 OVERPRESSURIZAT10ti PROTECTIOt4 CF PRESSURIZED WATER REACTORS WHILE OPERATING AT LOW TEMPERATURES A.

Background

General Design Criterien 15 of Appendix A,10 CFR 50, requires that "the Reactor Coolant Systen and associated auxiliary, control, and protection systems shall be designed with sufficient margin to assure that the design conditions of the reactor coolant pressure boundary are not exceeded during any condition of normal operation, including anticipated operational occurrences."

Anticipated operational occurrences, as defined in Appendix A of 10 CFR 50, are "those conditions of normal operation which are expected to occur one or more times during the life of the nuclear pcwer unit and include but are not limited to loss of power to all recirculation pumps, tripping of the turbine generator set, isolation of the main condenser, and loss of all offsite power."

Apperdix G of 10 CFR 50 provices the fracture tougnness requirements for reactor pressure vessels under a'l conditions.

To assure that the Apoendix G limits of the reactor coolant oressure boundary are not exceeded during any anticipated cperational occurrences, Technical Specification pressure-temperature limits are provided for operating the plant.

The primary concern of this position is that during startup and shutdown conditions at low temperature, especially in a water-solid condition, the reactor coolunt system pressure might exceed the reactor vessel pressure-temperature limitations in the Technical Specifications established for protection against brittl' fracture.

This inadvertent overpressurization could be generated by any one of a variety of mal-functions or coerator errors.

Many inciderits have occurred in operating plants as described in Reference 1.

Additional discussion on the background of this position is contained in Reference 1.

ENCL 3 (CONT)

IJNAN

~ B.

Branch Position 1.

A system should be designed and installed which will prevent exceeding the applicable Technical Specifications and Appendix G 1imits for the reactor coolant system while operation at low temperatures.

The system should be capable of relieving pressure during all anticipated overpressurization events at a rate sufficient to satisfy the Technical Specification limits, particularly while the reactor coolant system is in a water-solid condition.

2.

The system must be able to perform its function assuming any single active component failure.

Analyses using appropriate calculational techniques must be provided which demonstrate that the system will provide the required pressure relief capacity assuming the most limiting single active failure.

The cause for initiation of the event, e.g., operator error, component malfuncthn, will not be considered as the single active failure.

The analysis should assume the most limiting allouable ODerating conditions and systems configuration at tne time of the costulateo cause of the overoressure event.

All potential overpressurization events must be considered wnen establishina the worst case event.

Some evcnts may be prevented by protective interlocks or by locking out power.

't.me events should be revie.ted on an indivinual basit If the interlock / power lod out is accept able, i t car. Im excluded from Ine.oialyse, provided the controls tn prevent the event ar e in the plant fechnical Specifications.

3.

The system must meet the design requirements of IEEE 279 (see Implementation).

Tne system may be manually enablec, however, the electrical instrumentation anc control system must provice alarms to alert the operator to:

a, procerly enable the system at the correct plant condition during cooldo<.n, b.

indicate if a pressure transient is occurring.

4.

To assure operational readiness, the overpressure protection system must be tested in the following manner:

a.

A test must be performed to assure operability of the system electronics prior to each shutdown.

b.

A test for valve operability must, as a minimum be conducted as specified in the ASME Code Section XI.

c.

Subsequent to system, valve, or electronics maintenance, a test on that portion (s) of the system must be performed prior to declaring the system operational.

ENCL 3 (CONT) 5.

The system must meet the requirements of Regulatory Guide 1.26, "Ouality Group Classificat. ions and Standards for Water, Steam,

and Radioactive-Waste-Containing Components of fiuclear Power Plants" and Section 111 of the ASME Code.

6.

The overpressure protection system must be designed to function during an Operating Basis Earthquake.

It must not compromise the design criteria of any other safety-grade system with which it would interface, such that the requirements of Regulatory Guide 1.29, " Seismic Design Classification" are met.

7.

The overpressure protection system must not depend on the availability of offsite power to perform its function.

8.

Overpressure orotection systems which take credit for an active component (s) to mitigate the consequences of an overpressurization event must include additional analyses considering inadvertent system initiation / actuation or provide justification to show that existing analyses bound such an event.

C.

Implementation The Branch Technical Position, as specified in Section B, will be used in the review of all Preliminary Design Approval (PDA), Final Design Sproval (FDA), Manufacturing License (ML), Operating License (0L), and Construction Permit (CP) applications involving plant designs incorporating pressurized water reactors.

All aspects of the position will be applicable to all applications, including CP applications utilizing the replication option of the Commission's standardization program, that are docketed a f ter March 14, 1978.

All aspects of the position, with the exception of reasonable and justified deviations from IEEE 279 requirements, will be applicable to CP, OL, ML, PDA, and FDA applications docketed prior to March 14, 1978 but for which the licensing action has not been con'pleted as of fiarch 14, 1978.

Holders of appropriate PDA's will be informed by letter that all aspects of tne position with the exception of IEEE 279 will be applicable to their approved standard designs and that such designs should be modified, as necessary, to conform to the position.

Staff approval of proposed modifications can be applied for either by application by the PDA-holder on the PDA-docket or by each CP applicant referencing the standard design on its docket.

The following guidelines may be used, if necessary, to alleviate impacts on licensing schedules for plants involved in licensing proceedings nearing completion on March 14, 1978:

ENCL 3 (CONT)

{UfOPl -

allis I 1.

Those applicants issued on OL during the period between March 14, 1978 and a date 12 months thereafter may merely commit to meeting the position prior to OL issuance but shall, by license ccndition, be required to install all required staff-approved modifications prior to plant startup following tne first scheiuled refueling outage.

2.

Those applicants issued an OL beyond March 14, 1979 shall install all required staff-approved modifications prior to initial plant startup.

3.

Those applicants issued a CP, PDA, or ML during the period between March 14, 1978 and a date 6 months thereafter may merely commit to meeting the position but shall, by license condition, be required to amend the application, within 6 months of the date of issuance of the CP, PDA, or ML, to include a description of the proposed modi fications and the bases for their design, and a request for staff approval.

4.

Those applicants issued a CP, PDA, or ML af ter September 14, 1978 shall have staff approval of proposed modifications prior to issuance of tne CP, PDA, or ML.

D.

Re ferences 1.

NUREG-0138, Staff Discussion of Fif teen Technical Issues Listed in Attachment to November 3, 1976 Memorandum from Director, NRR, to NRR Staff.

ENCL 3 (CONT)

CATEGORY 4 MATTERS A.

Regulatory Guides not categorized Issue Date Number Revision Title 4/74 1.12 1

Instrumentation for Earthquakes 12/75 1.13 1

Spent Fuel Storage Facility Design Basis 8/75 1.14 1

Reactor Coolant Pump Flywheel Integrity 1/75 1.75 1

Physical Independence of Electric Systems 4/74 1.76 0

Design Basis Tornado for Nuclear Power Plants 9/75 1.79 1

Preoperational Testing of Emergency Core Cooling Systems for Pressurized Water Reactors 6/74 1.80 0

Preoperational Testing of Instrument Air Systems 6/74 1.82 0

Sumps for Emergency Core Cooling and Containment Spray Systems 7/75 1.83 1

Inservice Inspection of Pressurized Water Reactor Steam Generator Tubes 11/74 1.89 0

Qualification of Class lE Equipment for Nuclear Power Plants 12/74 1.93 0

Availability of Electric Power Sources 2/76 1.104 0

Overhead Crane Handling Systems for Nuclear Power Plants ENCLOSURE 4

. B.

SRP Criteria Impl ementa-Applicable tion Date Branch SRP Section Title 1.

11/24/75 MTEB 5.4.2.1 BTP MTEB-5-3,. Monitoring of Secondary Side Water Chemistry in PWR Steam Generators 2.

11/24/75 CSB 6.2.1 3TP CSB-6-1, Minimum 6.2.1 A Containment Pressure Model 6.2.lB for PWR ECCS Performance 6.2.1.2 Evaluation 6.2.1.3 6.2.1.4 6.2.1.5 3.

11/24/75 CSB 6.2.5 BTP CSB-6-2, Control of Combustible Gas Concentra-tions in Containment Following a loss-of-Coolant Accident 4.

11/24/75 CSB 6.2.3 BTP CSB-6-3, Determination of Bypass Leakage Path in Dual Containment Plants 5.

11/24/75 CSB 6.2.4 BTP CSB-6-4, Containment Purging During Normal Plant Operations 6.

11/24/75 ASB 9.1.4 BTP ASB-9.1, Overhead Handling Systems for Nuclear Power Plants 7.

11/24/75 ASB 10.4.9 BTP ASB-10.1, Design Guidelines for Auxiliary Feedwater System Pump Drive and Power Supply Diversity for PWR's 8.

11/24/75 SEB 3.5.3 Procedures for Composite Section Local Damage Prediction (SRP Section 3.5.3, par. II.l.C)

ENCLOSURE 4 (CONT)

. Implementa-Applicable tion Date Branch SRP Section Title 9.

11/24/75 SEB 3.7.1 Development of Design Time History for Soil-Structure Interaction Anglysis (SRP Section 3.7.1, par. II.2) 10.

11/24/75 SEB 3.7.2 Procedures for Seismic System Analysis (SRP Section 3.7.2 par. II) 11.

11/24/75 SEB 3.7.3 Procedures for Seismic Sub-system Analysis (SRP Section 3.7.3, par. II) 12.

11/24/75 SEB 3.8.1 Design and Construction of Concrete Containments) SRP Section 3.8.1, par. II) 13.

11/24/75 SEB 3.8.2 Design and Construction of Steel Containments (SRP Section 3.8.2, par. II) 14.

11/24/75 SEB 3.8.3 Structural Design Criteria for Category I Structures Inside Containment (SRP Section 3.8.3, par. II) 15.

11/24/75 SEB 3.8.4 Structural Design Criteria for Other Seismic Category I Structures (SRP Section 3.8.4, par. II) 16.

11/24/75 SEB 3.8.5 Structural Design Criteria for Foundations (SRP Section 3.8.5, par. II) 17.

11/24/75 SEB 3.7 Seismic Design Requirements for 11.2 Radwaste Sysems and Their Housing 11.3 Structures (SRP Section 11.2, BTP 11.4 ETSB 11-1, par. B.v)

ENCLOSURE 4 (CONT)

. Implementa-Applicable tion Date Branch SRP Section Title

18. 11/24/75 SEB 3.3.2 Tornado Load Effect Combi-nations (SRP Section 3.3.2, par. II.2.d)
19. 11/24/75 SEB 3.4.2 Dynamic Efects of Wave Action (SRP Section 3.4.2, par. II) 20.

10/01/75 ASB 10.4.7 Water Hammer for Steam Generators with Preheaters (SRP Section 10.4.7 par. I.2.b) 21.

11/24/75 AB 4.4 Thermal-Hydraulic Stability (SRP Section 4.4, par. II.5)

22. 11/24/75 RSB 5.2.5 Intersystem Leakage Detection (SRP Section 5.2.5 par.11.4) and R.G.1.45 23.

11/24/75 RSB 3.2.2 Main Steam Isolation Valve Leakage Control System (SRP Section 10.3 par. III.3 and BTP RSB-3.2)

C.

Other Positions Implementa-Applicable tion Date Branch SRP Section Title 1.

12/1/76 SEB 3.5.3 Ductility of Reinforced Concrete and Steel Structural Elements Subjected to Impactive or Impulstve Loads 2.

8/01/76 SEB 3.7.1 Response Spectra in Vertical Direction 3.

4/01/76 SEB 3.8.1 BWR Mark III Containment Pool 3.8.2 Dynamics 4

9/01/76 SEB 3.8.4 Air Blast Loads 5.

10/01/76 SEB 3.5.3 Tornado Missile Impact 6.

6/01/77 RSB 6.3 Passive Failures During Long-Term Cooling Following LOCA ENCLOSURE 4 (CONT)

Impl ement a-Applicable tion Date Branch SRP Section Title 7.

9/01/77 RSB 6.3 Control Room Position Indica-tion of Manual (Handwheel) Valves in the ECCS 8.

4/01/77 RSB 15.1.5 Lona-Term Recovery from Steamline Bream: Operator Action to Prevent Overpressurization 9.

12/01/77 RSB 5.4.6 Pump Operability Requirements 5.4.7 6.3

10. 3/28/78 RSB 3.5.1 Gravity Missiles, Vessel Seal Ring Missiles Inside Containment 11.

1/01/77 AB 4.4 Core Thermal-Hydraulic Analysis 12.

1/01/78 PSB 8.3 Degraded Grid Voltage Conditions

13. 6/01/76 CSB 6.2.1.2 Asymmetric Loads on Components Located Within Containment Sub-compartments
14. 9/01/77 CSB 6.2.6 Containment Leak Testing Program 15.

1/01/77 CSB 6.2.1.4 Containment Response Due to Main Steam Line Break and Failure of MSLIV to Close 16, 11/01/77 ASB 3.6.1 Main Steam and Feedwater Pipe 3.6.2 Failures 17.

1/01/77 ASB 9.2.2 Design Requirements for Cooling Water to Reactor Coolant Pumps

18. 8/01/76 ASB 10.4.7 Design Guidelines for Water Hammer in Steam Generators with Top Feedring Design (BTP ASB-10.2) 19.

1/01/76 ICSB 3.11 Environmental Control Systems for

~

Safety-Related Equipment ENCLOSURE 4 (CONT)

DESCRIPTION OF POSITIONS IDENTIFIED AS NRR CATEGORY 4 MATTERS IN ENCLOSURE 4, PARAGRAPH C Numbering scheme corresponds to that used in item C of Enclosure 4.

ENCLOSURE 4 (CONT)

C.1 DUCTILITY OF REINFORCED CONCRETE AND STEEL STRUCTURAL ELEMENTS SUBJECTED TO IMPACTIVE OR IMPULSIVE LOADS INTRODUCTION In the evaluation of overall response of reinforced concrete structural elements (e.g., missila barriers, columns, slabs, etc.) subjected to impactive or impulsive loads, such as impacts due to missiles, assumption of non.-linear response (i.e., ductility ratios greater than unity) of the structural elements is generally acceptable provided that the safety functions of the structural elements and those of safety-related systems and components supported or protected by the elements are maintained.

The following summarizes specific SEB interim positions for review and acceptance of ductility ratios for reinforced concrete and steel structural elements subjected to impactive and impulsive loads.

SPECIFIC POSITIONS 1.

REINFORCED CONCRETE MEMBERS 1.1 For beams, slabs, and walls where flexure controls design, the permissible ductility ratio ( u ) under impactive and impulsive loads should be taken as 0.05 for o-o'

>.005

=

u op 10 for p-p'

_.005

=

u where p and o'are the ratios of tensile and compressive reinforcing as defined in ACI-318-71 Code.

1.2 If use of a ductility ratio greater than 10 (i.e., u> 100) is required to demonstrate design adequacy of structural elements against impactive or impulsive loads, e.g., missile impact, such a usage should be identified in the plant SAR.

Information justifying the use of this relatively high ductility value shall be provided for SEB staff review.

ENCLOSURE 4 (CONT) 1.3 For beam-coltnns, walls, and slabs carrying axial compression loads and subject to impulsive or impactive loads producing flexure, the pemissible ductility ratio in flexure should be as follows:

(a)

Een cc,mpression controls the design, as defined by an interaction diagram, the pemissible ductility ratio shall be 1.3.

(b)

When the compression loads do not exceed 0.l fc 'Ag or one-third of that which would produce balanced conditions, which-ever is smaller, the pemissible ductility ratio can be as given in Section 1.1.

(c) The pemissible duti. ity ratio shall vary linearly from 1.3 to that given in Section 1.1 for conditions between those specified in (a) and (b).

(See Fig 1.)

1.4 For structural elements resisting axial compressive impulsive or impactive loads only, without flexure, the pemissible axial ductility ratio shall be 1.3.

1.5 For shear carried by concrete only

=

1.'

u For shear carried by concrete and stirrups c;- bent bars

= 1.3 u

For shear carried entirely by stirrups

= 3. 0 u

2.0 STRUCTURAL STEEL MEMBERS 2.1 For flexure compression and shear u

= 10.0 2.2 For coltanns with slenderness ratio (1/r) equal to or less than 20 p

= 1.3 ENCLOSURE 4 (CONT)

5, 1

3' 1"

A l' J

h

/?T^.

?

t

- S t

t TcR o o D f N

3 o

3

,r t

n TA R

L n

)k

'~

u i

f

- (

c M

o b

os o

s gv o

g I

vo R

h P

o L

O s

1 f.

G

,t e

T t

sukNy s h )%

F I

M e.g 6

Qe y'$

s t

On' L

\\

.I a.

i S6f o

)

b sr

\\

N f

i (w

ne P

b b

r p

P ee hhl 3

tl i

a

/

hsm i r g

c@

825 where 1 = effective length of the member r = the least radius of gyration For columns with slenderness ratio greater than 20 u = 1.0 2.3 For members subjected to tension u =.5 where cu= uniform ultimate strain of the material cY = strain at '1 eld of material C.2 RESPONSE SPECTRA IN THE VERTICAL DIRECTION Subsequent to the issuance of Regulatory Guide 1.60, the report

" Statistical Studies of Vertical and tiorizontal Earthquake Spectra" was issued in January 1976 by NRC as NUREG-0003. One of the important conclusions of this report is that the response spectrum for vertical motion can be taken as 2/3 the response spectrum for horizontal motion over the entire range of frequencies in the Western United States. According to Regulatory Guide 1.60, the vertical response spectrum is equal to the horizontal response spectrum between 3.5 cps and 33 cps. For the Western United States only, consistent with the latest available data in NUREG-0003, the option of taking the vertical design design response spectrum as 2/3 the horizontal response spectrum over the entire range of frequencies will be accepted.

For other locations, the vertical response spectrum will be the same as that given in Regulatory Guide 1.60.

C.3 BWR MARK III CONTAINMENT POOL DYNAMICS 1.

P00L SWELL a.

Bubble pressure, bulk swell and froth swell loads, drag pressure and other pool swell loais should be treated as abnormal pressure loads, P. Appropriate load combinations a

and load factors should be applied accordingly, b.

The pool swell loads and accident pressure may be combined in accordance with their actual time histories of occurrence.

ENCLOSURE 4 (CONT:

. 2.

SAFETY RELIEF VALVE (SRV) DISCHARGE a.

The SRV loads should be treated as live loads in all !oad combinations 1.5Pa where a load factor of 1.25 should be applied to the appropriate SRV loads.

b.

A single active failure causing one SRV discharge must be considered in combination with the Design Basis Accident (DBA).

c.

Appropriate multiple SRV discharge should be considered in combination wit:- the Small Break Accident (SBA) and Inter-mediate Break no:ident (IBA).

d.

Themai loads due to SRV discharge should be treated as T for normal operation and T for accident conditions, a

e.

The suppression pool liner should be designed in accordance with the ASME Boiler and Pressure Vessel Code, Division 1 Subsection NE to resist the SRV negative pressure, considering strength, buckling and low cycle fatigue.

C.4 AIR BLAST LOADS (Pa, Ta, To as defined in ACI 359-740)

The following interim position on air blast loadings on Nuclear Power Plant Structures should be used as guidance in evaluating analyses.

1.

An equivalent static pressure may be used for structural analysis purposes.

The equivalent static pressure should be obtained from the air blast reflected pressure or the overpressure by multiplying these pressures by a factor of two. Any proposed use of a dynamic load factor less than two should be treated on a case by case basis.

Whether the reflected pressure or t'le overpressure is to be used for individual structural elements depends on whether an incident blast wave could strike the surface of the element.

2.

No load factor need be specified for the air blast loads, and the load combination should be:

U=0+L+B where, U is the strength capacity of a section D is dead load L is live load B is air blast load.

3.

Elastic analysis for air blast is required for concrete structures of new plants. For steel structural elements, and also for rein-forced concrete elements in existing plants, some inelastic response may be permitted with appropriate limits on ductility ratios.

ENCLOSURE 4 (CONT) 4.

Air blast generated ground shock and air blast wind pressure may be ignored. Air blast generated missiles may be important in situations where explosions are postulated to occur in vessels which may fragment.

5.

Overturning and sliding stability should be assessed by multiplying the structure's full projected area by the equivaleft static pressure and assuming only the blast side of the structure is loaded. Justification for reducing the average equivalent static pressure on curved surfaces should be considered on a case by case basis.

6.

Internal supporting structures should also be analyzed for the effects of air blast to determine their ability to carry loads applied directly to exterior panels and slabs. Moreover.in vented structures, interior structures may require analysis even if they do not support exterior structures.

7.

The equivalent static pressure should be cor-idered as potentially acting both inward and outward.

C.5 TORNADO MISSILE PROTECTION As an interim measure,the minimum concrete wall and roof thickness for tornado missile protection will be as follows:

Wall Thickness Roof Thickness Concrete Strength (psi)

(inches)

(inches) 3000 27 24 Region I 4000 24 21 5000 21 18 3000 24 21 Region II 4000 21 18 5000 19 16 3000 21 18 Region III 4000 18 16 5000 16 14 These thicknesses are for protection against local effects only. Designers must establish independently the thickness requirements for overall structura response. Reinforcing steel should satisfy the provisions of Appendix C, ACI 349 (that is,.2% minimum, EWEF). The regions are described in Regulatory Guide 1.76.

ENCLOSURE 4 (CONT)

C.6 PASSIVE ECCS FAILURES DURING LONG-TERM COOLING FOLLOWING A LOCA Passive failures in the ECCS, having leak rates equal to or less than those from the sudden failure of a pump seal and which may occur d" ring the long-term cooling period following a postulated LOCA should be c an-f sidered.

To mitigate the effects of such leaks, a leak detection s3 tem having design features and bases as described below should be included in the plant design.

The leak detection system should include detectors and alarms which would alert the operator of passive ECCS leaks in sufficient time so that appro-priate diagnostic and corrective actions may be taken on a timely basis.

The diagnostic and corrective actions would include th. identification and isolation of the faulted ECCS line before the performance of more than one subsystem is degraded.

The design bases of the leak detection system should incl ude :

(1)

Identification and justification of the maximum leak rate; (2) Maximum allowable time for operator action and justification therefor; (3)

Demostration that the leak detection system is sensitive enough to initiate and alarm on a timely basis, i.e., with sufficient lead time to allow the operator to identify and isolate the faulted line before the leak can create undesireable consequences such as flooding of re-dundant equipment.

The minimut time to be considered is 30 minutes; (4)

Demonstration that the leak detection system can identify the faulted ECCS train and that the leak can be isolated; and (5) Alarms that conform with the criteria specified for the control room alarms and a leak detection system that conforms with the require-ments of IEEE-279, except that the single failure crite-ion need not be imposed.

C.7 CONTROL POOM POSITION INDICATION OF MANUAL (HANDWHEEL) VALVES Regulatory Guide 1.47 specifies, automatic position indication of each bypass or deliberately induced inoperable condition if the following three conditions are met:

(1) The byoass or inoperable condition affects a system that is designed to perform an automatic safety function.

ENCLOSURE 4 (CONT)

(2) The bypass or inoperable condition can reasonably be expected to occur more frequently than once per year.

(3) The bypass or inoperable condition is expected to occur when the system is nomally required to operate.

Revision one of the Standard Review Plan in Section 6.3 requires confomance with Regulatory Guide 1.47 with the intent being that any manual (handwheel) valve which could jeopardize the operation of the ECCS, if inadvertently left in the wrong position, must have position indication in the control room.

In the PDA extension reviews it is important to confim that standard '! signs include this design feature. Most standard designs do but t' matter was probably not specifically addressed in some of the fir

.sA reviews.

C.8 LONG-TERM RECOVERY FROM STEAM LINE BREAK - OPERATO ACTION TO PREVENT OVERPRESSURIZATION (PWR)

A steam line break causes cooldown of the primary system, shrinkage of RCS inventory and depletion of pressurizer fluid. Subsequent to plant trip, ECCS actuation, and main steam system isolation, the RCS inven-tory increases and expands, refilling the pressurizer. Without oper 'or action, replenishment of RCS inventory by the ECCS and expansion at low temperature could repressurize the reactor to an unacceptable pressure-temperature region thereby compromising reactor vessel integrity. Anal-yses are required to show that following a main steam line break that (i) no additional fuel failures result from the accident, and (ii) the pressures following the initiation of the break will not compromise the integrity of the reactor coolant pressure boundary giving due considera-tion to the changes in coolant and material temperatures.

The analyses should be based on the assumption that operator action will not be taken until ten minutes after initiation of the ECtS.

C.9 PUMP OPERABILITY REQUIREMENTS In some reviews, the staff has found reasonable doubt that some types of engineered safety feature pumps would continue to perform their safety function in the long term following an accident.

In such instances there has been followup, including pump redesign in some cases, to assure that long term performance could be met. The following kinds of infor-mation may be sought on a case-by-case basis where such doubt arises.

a.

Describe the tests performed to demonstrate that the pumps are capable of operating for extended periods under post-LOCA conditions, including the effects of debris. Discuss the damage to pump seals caused by debris over an extended period of operation.

ENCLOSURE 4 (CONT) b.

Provide detailed diagrams of all water cooled seals and compo-nents in the pumps.

Provide a description of the composition of the pump shaft c.

seals and the shafts. Provide an evaluation of loss.of shaft seals.

d.

Discuss he,, debris and post-LOCA environmental conditions were factored into the specifications and design of the pump.

C.10 GRAVITY MISSILES, VESSEL SEAL RING MISSILES INSIDE CONTAINMENT Safety related mystems should be protected against loss of function dua to internal missiles from sources such as those associated with pressurized components and rotating equipment. Such sources would include but not be limited to retaining bolts, control rod drive assemblies, the vessel seal ring, valve bonnets, and valve stems. A description of the methods used to afford protection against such potential missiles, including the bases therefor, should be provided (e.g., preferential orientation of the poten-tial missile sources, missile barriers, physical separation of redundant safety systems and components). An analysis of the effects of such poten-tial missiles on safety related systems, including metastably supported equipment which could fall upon impingement, should also be provided.

ENCLOSURE 4 (CONT)

, C.ll CORE THERMAL-HYDRAULIC ANALYSES In evaluating the thermal-hydraulic performance of the reactor coreithe following additional areas should be addressed:

1.

The effect of radial pressure gradients at the exit.of open lattice cores.

2.

The effect of radial pressure gradients in the upper plenum.

3.

The effect of fuel rod be sing.

In addition,a commitment to perform tests to verify the transient analysis methods and codes is required.

C.12 DEGRADED GRID VOLTAGE CONDITIONS As a result of the Millstone Unit Number 2 low grid voltage occurrence, the staff has developed additional requirements concerning (a) sustained degraded voltage conditions at the offsite power source, and (b) inter-action of the offsite and onsite emergency power systems. These additional requirements are defined in the following staff position.

1.

We require that a second level of voltage protection for the onsite power system be provided and that this second level of voltage pro-tection satisfy the following requirements:

a) The selection ot voltage and +

,e set points shall be determined from an analysis ce che voltage requirements of the safety-related loads at all onsite system distribution levels; b) The voltage protection shall include coincidence logic to preclude spurious trips of the offsite power source; ENCLOSURE 4 (CONT) c)

The time delay selected shall be based on the following conditions:

(i)

The allowable time delay, including margin, shall not exceed the maximum time delay that is assumed in the SAR accident analyses; (ii) The time delay shall minimize the effect of short duration disturbances from reducing the availability of the offsite power source (s); and (iii) The allowable time duration of a degraded voltage condition at all distribution system levels shall not result in failure of safety systems or components; (iv) The voltage sensors shall automatically initiate the disconnection of offsite power sources whenever the voltage set point and time delay limits have been exceeded; (v)

The voltage sensors shall be designed to satisfy the applicable requirements of IEEE Std. 279-1971 " Criteria for Protection Systems for Nuclear Power Generating Stations"; and (vi) The Technical Specifications shall include limiting conditionsfor operation, surveillance requirements, trip set points with minimum and maximum limits, and allowable values for the second-level voltage protection sensors and associated time delay devices.

2.

We require that the system design automatically prevent load shedding of the emergency buses once the onsite sources are supplying power to all sequenced loads on the emergency buses.

The design shall also include the capability of the load shedding feature to be automatically reinstated if the onsite source supply breakers are tripped. The automatic bypass and reinstatement feature shall be verified during the periodic testing identified in Item 3 of this position.

3.

We require that the Technical Specifications include a test require-ment to demonstrate the full functional operability and independence of the onsite power sources at least once per 18 months during shut-down. The Technical Specifications shall include a requirement for tests:

(a) simulating loss of offsite power; (b) simulating loss of offsite power in conjunction with a safety injection actuation signal; and (c) simulating interruption and subsequent reconnection of onsite power sources to their respective buses.

ENCL 6SURE 4 (CONT) 4.

The voltage levels at the safety-related buses should be optimized for the full load and minimum load conditions that are expected throughout the anticipated range of voltage variations of the offsite power source by appropriate adjust-ment of the voltage tap settings of the intervening transformers.

We require that the adequacy of the design in this regard be verified by actual measurement, and by correlation-of measured values with analysis results.

C.1 '

ASYMMETRIC LOADS ON COMPONENTS LOCATED WITHIN CONTAINMENT SUBCOMPARTMENTS In the unlikely event of a pipe rupture inside a major component sub-compartment, the initial blowdown transient would lead to pressure loadings on both the structure and the enclosed component (s). The staf f's generic Category A Task Action Plan A-2 is designed to develop generic resolutions for this matter. Our present schedule calls for completing A-2 for PWR's during the first quarter,1979. Pending completion of A-2, the staff is implementing the following program:

1. For PWRs at the CP/PDA stage of review, the staff requires appli-cants to comit to address the safety issue as part of their appli-cation for an operating license.

2.

For PWRs at the OL/FDA stage of review, the staff requires case-by-case analyses, including implementation of any indicated corrective measusres prior to the issuance of an operating license.

3.

For BWRs, for which this issue is expected to be of lesser safety significance, the asymetric loading conditions will be evaluated on a case-specific basis prior to the issuance of an operating license.

For those cases which analyses are required, we request the performance of a subcompartment, multi-node pressure response analysis of the pressure transient resulting from postulated hot-leg and cold-leg (pump suction and discharge) reactor coolant system pipe ruptures within the reactor cavity, pipe penetrations, and steam generator compartments. Provide similar analyses for the pressurizer surge and spray lines, and other high energy lines located in containment compartments that may be subject to pressurization. Show how the results of these analyses are used in the design of structures and component supports.

ENCLOSURE 4 (CONT)

C.14 CONTAINMENT LEAK TESTING PROGRAM To avoid difficulties experienced in this area in recent OL reviews, the staff has increased its scope of inquiry at the CP/PDA stage of review. For this purpose, the following information with regard to the containment leak testing program should be supplied.

Those systems that will remain fluid filled for the Type A test a.

should be identified and justification given, b.

Show the design provisions that will pemit the personnel air-lock door seals and the entire air lock to be tested.

c.

For each penetration,i.e., fluid system piping, instrument, electrical, and equipment and personnel access penerations, identify the Type B and/or Type C local leak testing that will be done.

d.

Verify that containment penetratiorc fitted with expansion bellows will be tested at Pa.

Identify any penetration fitted with expansion bellows that does not have the design capability for Type B testing and provide justification.

C.15 CONTAINMENT RESPONSE DUE TO MAIN STEAM LINE BREAK AND MSLIV FAILURE In recent CP and OL application reviews, the results of analyses for a postulated main steam line break accident (MSLB) for designs utilizing pressurized water reactors with conventional containments show that the peak calculated containment temperature can exceed for a short time period the environmental qualification temperature-time envelope for safety related instruments and components. This matter was also discussed in Issue No.1 of NUREG-0138 and Issue No. 25 of NUREG-0153.

The signifiance of the matter is that it could result in a requirement for requalifying safety-related equipment to higher time-temperature envelopes.

The staff's generic Category A Task Action Plans A-21 and A-24 are designed to develop generic resolutions for these matters. The presently scheduled completion dates for A-21 and A-24 (Short Tem Portion) are first quarter,1979 and fourth quarter,1978, respectively.

Pending completion of A-21 and A-24, some interim guidance will be used as detailed below.

We have developed and are implementing a plan in which all applicants for construction pemits and operating licenses and those already issued con-struction permits must provide information to establish a conservative temperature-time envelope.

ENCLOSURE 4 (CONT)

. Therefore, describe and justify the analytical model used to conservatively detemine the maximum containment temperature and pressure for a spectrum of postulated main steam line breaks for various reactor power levels.

Include the following in the discussion.

(1) Provide single active failure analyses which specifically identify those safety grade systems and components relied upon to limit the mass and energy release and containment pressure /

temperature response. The single failure analyses should include, but not necessarily bs limited to: main steam and connected systems isolation; feedwater auxiliary feedwater, and connected systems isolation; feedwater, condensate, and auxiliary feedwater pump trip, and auxiliary feedwater run-out cont ol system; the loss of or availability of offsite power; d1ewl failure when loss of offsite power is evaluated; and pa1.ial loss of containment cooling systems.

(2)

Discuss and justify the assumptions made regarding the time at which active containment heat removal systems become effective.

(3) Discuss and justify the heat transfer correlation (s) (e.g., Tagami, Uchida) used to calculate the heat transfer from the containment atmosphere to the passive heat sinks, and provide a plot of the heat transfer coefficient versus time for the most severe steam line break accident analyzed.

(4)

Specify and justify the temperature used in the calculation of condensing heat transfer to the passive heat sinks; i.e.,

specify whether the saturation temperature corresponding to the partial pressure of vapor, or the atmosphere temperature (which may be superheated)was used.

(5) Discuss and justify the analytical model including the thermodynamic equations used to account for the removal of the condensed mass from the contaanment atmosphere due to condensing heat transfer to the passive heat sinks; (6) Provide a table of the peak values of containment atmosphere temperature and pressure for the spectrum of break areas and power levels analyzed; (7) For the case which results in the maximum containment atmosphere temperature, graphically show the containment atmosphere temperature, the containment liner temperature, and the containment concrete temperature as a function of time. Compare the calculated contain-ment atmosphere temperature response to the temperature profile used in the environmental qualification program for those safety related instruments and mechanical components needed to mitigate the consequences of the assumed main steam line break and effect safe reactor shutdown; ENCLOSURE 4 (CONT)

(8) For the case whicn results in maximum containment atmosphere pressure, graphically show the containment pressure as a function of time; and (9) For the case which results in the maximum containment atmosphere t cessure and temperature, provide the mass and energy release data in tabular form.

In order tc demonstrate that safety-related equipment has been adequately qualified as described above, provide the following information regard-ing its environmental qualification.

(1)

Provide a comprehensive list of equipment required to be operational in the event of a main steamline break (MSLB) accident. The list should include, but not necessarily be limited to, the following safety related equipment:

(a) Electrical containment penetrations; (b) Pressure transmitters; (c) Containment isolation valves; (d) Electrical power cables; (e) Electrical instrumentation cable; and (f) Level transmitters.

Describe the qualification testing that was, or will be, done on this equipment.

Include a discussion of the test environment, namely, the temperature, pressure, moisture content, and chemical spray, as a function of time.

(2)

It is our position that the themal analysis of safety related equipment which may be exposed to the containment atmosphere following a main steam line break accident should be based on the following:

(a) A condensing heat transfer coeffic.ient based on the recommendations in Branch Technical Position CSB 6-1,

" Minimum Containment Pressure Model for PWR ECCS Performance Evaluation,"should be used.

(b) A convective heat transfer coefficient should be used when the condensing heat flux is calculated to be less than the convective heat flux. During the blowdown period it is appropriate to use a conservatively evaluated forced convection heat transfer correlation. For example, ENCLOSURE 4 (CONT)

Nu = C(Re)

Where Nu = Nusselt No.

Re = Reynolds No.

empirical constants dependent on C

a geometry and Reynolds No.

Since the Reynolds number is dependent on velocity, it is necessary to evaluate the forced flow currents which will be generated by the steam generaor blowdown. The CVTR experiments provide limited data in this regard. Convective currents of from 10 ft/sec to 30 ft/sec were measured locally. We recomend that the CVTR test results be extrapolated conservatively to obtain forced flow currents ta detemine the convective heat transfer coefficient during the blowdown period. After the blowdown has ceased or been reduced to a negligibly low value, a natural convection heat transfer correlation is acceptable.

(3)

For each component where themal analysis is done in conjunction with an environmental test at a temperature lower than the peak calculated temperature following a main steam line break accident compare the test thermal response of the component with the accident themal analysis of the component. Provide the basis by which the component themal response was developed from the environmental qualification test program. For instance, graphically show the themocouple data and discuss the themocouple locations, method of attachment, and perfomance characteristics, or provide a detailed discussion of the analytical model used to evaluate the component themal response during the test. This evaluation should be perfomed for the potential points of failure such as thin cross-sections and temperature sensitive parts where themal stressing, temperature-related degradation, steam or chemical interaction at elevated temperatures, or other themal effects could result in the failure of the component mechanically or electrically.

If the component themal response comparison results in the prediction of a more severe themal transient for the accident conditions than for the qualification test, provide justification thal the affected component will perfom its intended function during a MSLB accident, or provide protection for the component whch would appropriately limit the thamal effects.

ENCLOSURE 4 (CONT)

. C.16 ENVIRONMENTAL EFFECT OF PIPE FAILURES Identify the " break exclusion" regions of the main steam and feedwater lines. Compartments that contain break exclusion regions of main steam and feedwater lines and any safety related equipment in these compartments should be designed to with-stand the environmental effects (pressure, temperature, humidity and floojing) of a crack with a break area equal to the cross sectional area of the ' break excluded' pipe.

C.17 DESIGN REQUIREMENTS FOR COOLING WATER TO REACTOR COOLANT PUMPS Demonstrate that the reactor coolant system (RCS) pump seal injection flow will be automatically maintained for all transients and accidents or that enough time and information are availahlo to norm 4+

corrective action by an operator.

' ' " ~ '

We have established the following criteria for that portion of the component cooling water (CCW) system which interfaces with the reactor coolant pumps to supply cooling water to pump seals and bearings during normal operation, anticipated transients, and accidents.

1. A single active failure in the component cooling water system shall not result in fuel damage or a breach of the reactor coolant pressere boundary (RCPB) caused by an extended loss of cooling to ona or more pumps. Single active failures include operator error, spurious actuation of motor-operated valves, and loss of CCW pumps.
2. A pipe crack or other accident (unanticipated occurrence) shall not result in either a breach of the RCPB or excessive fuel damage when an extended loss of cooling to two or more RC pumps occurs. A single active falure shall be considered when evaluating the consequences of this accident. Moderate leakage cracks should be determined in accordance with Branch Technical Position ASB 3-1.

In order to meet the criteria established above, an NSSS inter-face requirement should be imposed on the balance-of-plant CCW system that provides cooling water to the RC pump seals and motor and pump bearings, so that the system will meet the following con-ditions:

n ENCLOSURE 4 (CONT) 1.

That portion of the component cooling water (CCW) system which supplies cooling water to the reactor coolant pumps and motors may be designed to non-seismic Category I requiremants and Quality Group D if it can be demonstrated that the reactor coolant pumps will operate without component cooling water for at least 30 minutes without loss of function or the need for operator pro-tective action.

In addition, safety grade instrumentation including alarms should be provided to detect the loss.of component cooling water to the reactor coolant pumps and motors, and to notify the operator in the control room. The entire instrumentation system, including audible and visual alarms, should meet the requirements of IEEE Std 279-1971.

If it is not demonstrated that the reactor coolant pumps and motors will operate at least 30 minutes without loss of function or operator protective action, then the design of the CCW sys tem must meet the following requirements:

1.

Safety grade instrumentation consistent with the criteria for the reactor protection system shall be provided to initiate automatic protection of the plant. For this case, the component cooling water supply to the seals and pump and motor bearings may be designed to non-seismic Ca tegory I require-ments and Quality Group D; or 2.

The component cooling water supply to the pumps and motors shall be capable of withstanding a single active failure or a moderate energy line crack as defined in our Branch Technical Position APCSB 3-1 and be designed to seismic Catecory I, Quality Group D and ASME Section III, Class 3 requirements.

~

The reactor coolant (RC) pumps and motors are within the NSSS scope of design. Therefore, in order to demonstrate that an RC pump design can operate with loss of component cooling water for at least 30 minutes without loss of function or the need for operator action, the following must be provided:

1.

A detailed description of the events following the loss of component cooling water to the RC pumps and an analysis demon-strating that no consequences important to safety may result from this event.

Include a discussion of the effect that the loss of cooling water to the seal coolers has on the RC pump seals. Show that the loss of cooling water does not result in a LOCA due to seal failure.

ENCLOSURE 4 (CONT) 2.

A detailed analysis to show that loss of cooling water to the RC pumps and motors will not cause a loss of the flow coastdown characteristics or cause seizure of the pumps, assuming no administrative action is taken. The response should include a detailed description of the calculation procedure including:

a.

The equations used.

b.

The parameters used in the equations, such as the design parameters for the motor bearings, motor, pump and any other equipment entering into the calculations, and material property values for the oil and metal parts, c.

A discussion of the effects of possible variations in part dimensions and material propertics, such as bearing clearance tolerances and misalignment.

d.

A description of the cooling and lubricating systems (with appropriate figures) associated with the RC pump and motor and their design criteria and standards.

e.

Infomation to verify the applicability of the equations and material properties chosen for the analysis (i.e.,

references should be listed, and if empirical relations are used, provide a comparison of their range of appli-cation to the range used in the analysis).

Should an analysis be provided to demonstrate that loss of component cooling water to the RC pumps and motor assembly is acceptable, we will require certain modifications to the plant Technical Specifications and an RC pump test conducted under operating condtions and with component cooling water terminated for a specified period of time to verify the analysis.

C.18 WATER HAMMER IN STEAM GENERATORS WITH TOP FEEDRING DESIGN Events such as damage to the feedwater system piping at Indian Point Unit No. 2, November 13, 1973, and at other plants, could originate as a consequence of uncovering of the feedwater sparger in the steam generator or uncovering of the steam generator feedwater inlet nozzles. Subsequent events may in turn lead to the generation of a pressure wave that is propageted through the pipes and could result in unacceptable damage.

ENCLC9URE 4 (CONT)

For CP/PDA and OL/FDA applications, provide the following for steam generators utilizing top feed:

1.

grevent or delay water draining from the feedring following a drop in steam generator water level by means such as,J-Tubes; 2.

Minimize the volume of feedwater piping external to the steam generator whch auld pocket steam using the shortest possible (less than seven feet) horizontal run of inlet piping to the steam generator feedring; and 3.

Perform tests acceptable to the staff to verify that unacceptable feed-water hamer will not occur using the plant operating procedures for normal and emergency restoration of steam generator water level following loss of normal feedwater and possible draining of the feedring. Provide the procedures for these tests for staff approval before conducting the tests.

Furthemore, we request that the following be provided:

a.

Describe normal operating occurrences of transients that could cause the water level in the steam generator to drop below the sparger or nozzles to cause uncovering and allow steam to enter the sparger and feedwater piping.

b.

Describe your criteria or show by isometric diagrams, the routing of the feedwater piping from the steam generators outwards to beyond the containment structure up to the outer isolation valve and restraint.

c.

Describe any analysis on the piping system including any forcing functions that will be perfomed or the results of test programs to verify that,either uncovering of feedwater lines could not occur or that, if it did occur, unacceptable damage such as the experience at the Indian Point Unit No. 2 facility would not result wf th your design.

ENCLOSURE 4 (CONT)

C.19 ENVIRONMENTAL CATROL SYSTEMS FOR SAFETY RELATED E0llIPMENT Most plant areas that contain safety related equipment depend on the continuous operation of environmental control systems to maintain the environment in those areas within the range of environmental qualification of the safety related equipment installed in those areas.

It appears that there are no requireme'nts for maintaining these environmental control :ystems in operation while the plant is shutdown or in hot standby conditions. During periods when these environmental control systems are shutdown, the safety related equipment could be exposed to environmental conditions for which it has not been qualified. Therefore, the safety related equipment should be qualified to the extreme envi;'onmental conditions that could occur when the control equipment is shutdown or these environmental control systems should operate continuously to maintain the environmental conditions within the qualification limits of the safety related equipment.

In the second case an environmental monitoring system that will alarm when the environmental conditions exceed those for which safety related equipment is qualified shall be provided. This environmental monitoring system shall (1) be of high quality, (2) be periodically tested and calibrated to verify its continued functioning, (3) be energized from continuous power sourcess and (4) provide a continuous record of the environmental parameters during the time the environmental conditions exceed the nonnal limits.

ENCLOSURE 4 (CONT)

YEAA

[on asog UNITED STATES y'

NUCLEAR REGULATORY COMMisslON

{

WASHINGTON, D. C. 20555 3

    • ,...../

JAN 2 91979 Docket No:

50-341 APPLICANT: Detroit Edisori Company FACILITY:

Enrico Fermi Atomic Power Plant, Unit 2

SUBJECT:

SUMMARY

OF JANUARY 16, 1979 VISIT TO FERMI 2 PLANT Members of the NRC staff in the Office of Nuclear Reactor Regulation visited the Fermi 2 Plant to observe and discuss safety features as a part of its review of the Detroit Edison Company's application for a license to operate Fermi 2.

A list of participants is enclosed.

Most cf the day was used to tour the plant. A scale model of the reactor, connected piping and components within the drywell, and a cut-away scale model of the drywell, torus and sacrifical shield was very useful in visualizing these components.

Regions of U1e plant that were visited included the control room, the reactor buildinq refueling floor, the torus - both inside and outside - the drywell underneath the reactor vessel, the turbine building operating floor, the natural draft cooling towers and the residual heat removal (RHR) building, incion;m the roof of the building from which the RHR cooling towers could be seea at close range.

Some aspects of the requests fa information transnitted previously from the Reactor Systems Branch and Containment Sy~tems Branch were briefly discussed.

In addition, draft requests fram the Material Engineering Branch regarding exemptions from the Commission's regulations in Appendices G and H of 10 CFR Part 50 sua 10 CFR 50.55 a(g) we re briefly nentioned.

The MTEB requests will be tran;mitted by letter di ring the weR of January 22, 1979.

The applicant indicated that responses to outstanding requests on limiting torus water temperature and maximum pmnissible enargency service water temperature will be transmitted by ebruary 26,1979. The applicant will confirm its response to the staff's question that indicated the diesel generator exhaust outlets will be protected from toraado -

induced missiles coming from any direction.

AA)

L. L. Kintne, Project Manager Light Water Reactors Branch No.1 Division of Project Management

Enclosure:

Attendance List 7902140006

[

cc:

See next page

Dr. Wayne H. Jens JAN 2 91979 Dr. Wayne H. Jens.

Mr. Jeffrey A. Alson Assistant Vice President 772 Green Street, Building 4 Engineering & Construction Ypsilanti, Michigan 48197 Detroit Edison Company 2000 Second Avenue Mr. David Hiller Detroit, Michigan 48226 University of Michigan Law School cc:

Eugune B. Thomas, Jr., Esq.

Hutchins Hall LeBoeuf, Lamb, Leiby & MacRae Ann Arbor, Michigan 48109 1757 N. Street, N.W.

Washington, D. C.

20036 Mrs. Martha Drake 230 Fairview Peter A. Marquardt, Esq.

Petoskey, Michiaan 49770 Co-Counsel The Detroit Edison Company 2000 Second Avenue Detroit, Michigan 48226 Mr. William J. Fahrner Project Manager - Fermi 2 The Detroit Edison Company 2000 Second Avenue Detroit, Michigan 48226 Larry E. Schuerman Licensing Engineer - Fermi 2 Detroit Edison Company 2000 Second Avenue Detroit Michigan 48226 Charles Bechhoefer, dsq., Chairman Atomic Safety & Licensing Board Panel V. S. Nuclear Regulatory Commission Washington, D. C.

20555 Dr. David R. Schnik Department of Oceanography Texas A & M University College Station, Texas 77840 Mr. Frederick J. Shon Atomic Safety & Licensing Board Panel U. S. Nuclear Regulatory Commission Washington, D. C.

20555

~

ENCLOSURE ATTENDANCE LIST JANUARY 16, 1979 VISIT TO FERMI 2 PLANT NRC Detroit Edison Company Chuck Graves Mel Batch Larry Bell Larry E. Schuennan Felix Litton E. Lusis Les Kintner Lawrence Wooden T. Huang Daniel Lehnert

NRC PGL:C DCCL"viENT R0t)M s

^

3 UNITED STATES CF AMERICA

~

}

w i

NUCLLAR REGULATORY CCMMISSICN

/

N/

Before the Atomic Safety and Licensinc Board In the Matter of

)

)

PENNSYLVANIA PCWER AND LIGHT COMPANY

)

and

)

Docket Nos. 50-387 ALLEGHENY ELECTRIC COOPERATIVI, INC.

)

50-388

)

(Susquehanna Steam Electric Station,

)

Units 1 and 2)

)

APPLICANTS' RESPCNSE TO SUPPLEMENTS TO PETITICN FOR LEAVE TO INTERVENE OF CITIZENS AGAINST NCCLEAR DANGERS In seven filings between Decemher 28, 1978, and January 10, 1979, the Citizens Against Nuclear Dangers (CAND) have supple-mented their Petition for Leave to Intervene by adding a series of contentions.

Pursuant to the Licensing Board's December 14, 1978 Order Scheduling Prehearing Conference, Applicants submit their response to petitioner's contentions.

Applicants assume that CAND intends its seven filings to supersede its earlier petition.

This would appear to be the case since each of the issues dealt with in the contentions in its original submittals have been included in one or more of the con-tentions in its supplemental filings.

Consequently, Applicants have treated the sixteen contentions in the seven supplemental filings as the complete statement of the Citizens' cententiens.

For the purpose of respending, Applicants have numbered the con-tentions in the folicwing manner:

% 911o n o

, December 28, 1978 1.

National Crisis Relocation Program 2.

Liability for Damage to Dairy Farmers 3.

Loss of Coolant Accident 4.

Armed Attack on Spent Fuel Pool December 29, 1978 5.

Reserve Margins 6.

Liquid Releases of Chlorine, Cesium and Cobalt January 3, 1979 7.

Low Susquehanna River Flow 8.

Decommissioning Januarv 5, 1979 9.

Evacuation Plans 10.

Radiation Studies January 8, 1979 11.

Inadequate Construction Monitoring 12.

Transportation of Nuclear Fuel January 9, 1979 13.

Spent Fuel Storage 14.

Transmission Line Impacts January 10, 1979 15.

Health Effects of Low-Level Radiation 16.

Shipment of Highly Enriched Uranium to Rumania

, Contention 1 (National Crisis Relocation Program)

This contention states that the Salem Township area, including the Susquehanna Steam Electric Station (SSES) site and its surroundings, has been designated by Civil Defense officials as a " host area" for people who might be evacuated from Wilkes-Barre in the event of a foreign nuclear attack.

The contention then states that SSES would itself be a target for a nuclear attack, thus making the Salem Township environs unsuitable as a " host area."

This contention appears to be a clear challenge to NRC regulations.

The Commission's regulations state that an applictnt:

is not required to provide for design features or other measures for the specific purpose of protecting against the effects of (a) attacks and destruc-tive acts, including sabotage, directed against the facility by an enemy of the United States, whether a foreign govern-ment or other person 10 CFR 550.13.

The contention would clearly seem to involve matters involving acts of war, which are excluded by this regulation from consideration in licensing hearings.

This regulacion and the Commission's policy of not considering military attacks have been upheld by the courts.

Siegel v.

Atomic Enerev Ccmmission, 400 F.2d 773

'D.

C.

Cir. 1968).

To the extent that CAND is concerned with the " host area" designation, that matter should be raised with apprcpriate civil def ense authorities not NRC.

. Contention 2 (Liability for Damage to Dairy Farmers)

The basic thrust of this contention appears to be that the Pennsylvania General Assembly must take some type of action because Applicants assertedly " claim no liability" for postulated damage to the dairy industry.

Under the Price-Anderson Act (42 U.S.C.

S2210), Appli-cants must obtain private insurance coverage and federal indemnification totalling S560 million for any single nuclear incident.

As the number of nuclear plants increases, the statute provides that the $560 million figure will increase.

Applicants' liability for damages is, by this statute, limited to this amount.

The United States Supreme Court has upheld the constitutionality of this limitation of liability.

Duke Power Co. v.

Carolina Environmental Study Group, Inc., 438 U.S.

59 (1978).

To the extent that the contention challenges this statutory scheme, it raises issues outside the scope of this proceeding.

See, e.c.

Potomac Electric Power Co. (Douglas Point Nuclear Generating Station, Units 1 and 2), ALA3-218, 8 AEC 79, 81 (1974).

Like-wise, to the extent that the contention seeks action by the Pennsylvania General Assembly, it is raising issues which are not within the jurisdiction of the Licensing Board or the Commission.

One of the paragraphs if the contention does set fo rth an issue which Applicants believe shculd be admitted as a contention.

That paragraph states :

. [S]eventy million gallons o_ radioactive evaporated water to be vented daily from the Applicants' atomic power plant at Salem Township, will pose an economic threat to the dairy industry.

The two preceeding paragraphs could be considered to constitute a basis for this contention:

Whereas, dairy farming is a major industry in the Eastern-Central area of Pennsylvania, cital to the total economy of the Common-wealth.

Whereas, milk production in this area w il increase substantially in the years ahead to meet the demands for raw milk needed to supply three large cheese factorie now under construction.

Although Applicants do not agree that " seventy million gallons of radioactive evaporated water will be vented daily from Applicants' atomic power plant" (the water to be evap-orated from the cooling towers is not radioactive) or that operation of the plant "will pose an economic threat to the dairy industry", these are issues to be decided on the merits rather than at the contention stage.

Finally, it is Applicants' position that the paragraph involving the asserted unpreparedness of Applicants and certain State agencies "to safeguard the dairymen for loss of livestock in the event the herds must be destroyed due to radioactive contamination" raises issues not properly before this Licensing Board in that it appears to challenge Price-Anderson Act limitations and positions of state agencies not properly wirhin the jurisdiction of the Nuclear Regularcry Commission.

Contention 3 (Loss of Coolant Accident)

CAND contends that no operating licenses for SSES should be granted until the currently on-going Loss of Fluid Test (LOFT) of emergency core cooling systems (ECCS) has been completed and commented upon by all parties.

Applicants object to this contention in that it is a challenge to Commission regulations and fails to cceply with 10 CPR S2.758.

The performance requirements fo-ECCS are specified in NRC regulations.

10 CFR 550.46 and Appendix K to Part 50.

CAND does not claim that the Subcuehanna ECCS fails to comply with these regulations and, as shown in the Final Safety Analysis Report (FSAR), the Susquehanna ECCS fully meets NRC regulations.

The fact that there may be on-going tests involving ECCS criteria, design, or performance cannot impose obligations other than chose in NRC regulations.

It is worth noting that LOFT was in progress when the Commis -

sion, after an extraordinarily elaborate rulemaking hearing, issued the ECCS regulations.

Yet nowhere in the regulations or the Commission's decision announcing those regulations is there any indication that further licensing must await completion of LOFT.

Contentien 4 (Armed Attack on Spent Fuel Pcol)

This contention argues that the " spent fuel containment structure",

i.e.

the spent fuel pool, must be designed

. to withstand the direct impact of sus-taining rounds of high explosives, e'.ther from a general aviation bombardment or para-military mc 7 tar rocket fire.

CAND states that should such a "terroristic attack by armed extremists" occur, "a large scale, high level radior.ctive release into the atmosphere of catastrophic proportions could result."

Applicants believe that the contention is a challenge to Commission regulations and should be rejected.

First, the type of attack which CAND postulates would seem to fall within the scope of 10 CFR 550.13 (see discussion of Contan-tion 1 above) and is thus the type of " attacks and destructive acts" against which the facility need not be designed.

Second, the contention would require physical security measures above and beyond the threat level specified in 10 CFR S7 3. 55 (a).

That regulation requires a licensee to provide a physical protection system and security organiza-tion to protect against (1)

A determined violent external assault, attack by stealth, or deceptive actions, of several persons with the fol-lowing attributes, assistance and equip-ment:

(i) Well-trained (including military training and skills) and dedicated individ-uals, (ii) Inside assistance which may in-clude a knowledgeable individual who attempts to participate in both a passive role (e.g.,

provide information) and an active role (e.g.,

facilitate entrance and exit, disable alarms and cc=munications, participate in violent attack), (iii) Suitable weapons, up to and including hand-held automatic weapons, equipped with silencers and havinc effective long range accuracy, (iv) Hand-carried equip-ment, including incapacitating agents and ex-

. plosives for use as tools of entry or other-wise destroyinc the reactor integrity, and (2)

An internal threat of an insider, including an employee (in any position).

" General aviation bombardment" and " para-military mortar rocket fire" postulated in this contention far exceed this threat level.

By arguing that the facility must be designed to withstand such attacks, the contention is taking issue with Commission regulations and is thus not appropriate for litigation in this proceeding.

Contention 5 (Reserve Margins)

This contention contains several aspects which are beyond the scope of this proceeding.

First, it requests the Licensing Board to direct the Pennsylvania Public Utility Commission to investigate the consequences of inaccurate projections of demand for electricity "in order to establish equity for rate-payers."

The Licensing Board has no such power and has no jurisdiction over setting of rates.

Second, it requests the Liceising Board to order a halt in construc-tion at the Susquehnnna site.

The question of continued construction is not witP'n the scope of this operating license proceeding.

Third, te calls for NRC to " comply with the National Energy Program, enunciate by the President before a joint cession of Congress (April 20, 197 7) " *.

This

'The energy gcal referred to in the contentien cf " reducing annual growth of United States energy demand to less than two percent" is, in any event,,a goal for energy demand, not for electricity demand.

Footnote continued on page 3

. type of broad claim, unrelated to this proceeding, raises no litigable issues.

However, several of the introductory paragraphs do raise appropriate issues.

Thus, CAND states:

the major Applicant [ Pennsylvania Power & Light (PP&L)] presently has electric generating over-capacity, estimated to range as high as forty percent within its service area, the major Applicant justified construc-tion of the Salem Township atomic power plant based on future electric demand projections that never happened to materialize, Applicants basically agree with these statements.

PP&L has, and will continue to have for some time, reserve levels "as high as forty percent."

PP&L's earlier forecasts, on which the decision to construct SSES were based, turned out to be too high.

Chapter 1 of Applicants' Environmental P port-operating Licensing Stage, describes this situation in detail.

While these statements by CAND would ordinarily form the core of a valid contention, in this instance there is nothing to litigate since Applicants do not challenge the statements.

These two statements can thus be considered as admissions by Apolicants.

See 10 CFR 52.742.

These admissions, however, cro-vid: no basis for denying issuance of operating licenses.

As shown in Applicants' Environmental Report, operation of the units is justified on economic grounds notwithstanding the reserve levels identified in the contention.

See Environmental Fcornote continued from page 3 Furthermore, it is a goal for 1985, which is after Suscuehanna is scheduled to commence operation.

See President's Address Delivered Before a Joint Session of Congress, April 20, 1977, 13 Weekly Compilation of Presidential Documents at 566.

Report, 51.1.

CAND has not challenged this justification.

Thus these statements by CAND, even if accepted as a content-tion, do not require hearing consideration.

Contention 6 (Licuid Releases of Chlorine, Cesium and Cobalt)

This contention asserts that releases of chlorine and

" nuclear waste materials (such as cesium 137 and cobalt 60)"

from the Susquehanna facility "will pose a serious public health danger to the citizens of Danville Applicants do not object to the admission of a contention on the public health danger to the citizens of Danville from releases of chlorine, cesium 137 and cobalt 60, the specific releases identified by CAND.

Notwithstanding Applicants' compliance with chlorine discharge limits established under the Federal Water Pollution Control Act and ccmpliance with liquid radiu-active discharge limits of NRC regulations (i.e. 10 CFR Part 20 and Appendix I to Part 50), the health effects of such dis-charges are an appropriate issue in the context of the Commission's responsibilities under the National Environmental Policy Act (NEPA).

Applicants would present evidence showing that these discharges would cause no adverse health effects.

It is Applicants' position, however, that the portions of the contention requesting that NRC impose a "zero release" limit on discharges of chlorine and " nuclear wastes" are a challenge to regulations and statutes.

NRC regulations permit liquid radioactive discharges so long as they meet the requirements of 10 CFR Part 20 and Appendix I to Part 50.

A "zero release" requirement wculd represent a chal-lenge to those regulations.

As to chlorine releases, NRC is by statute prohibited from setting any restrictions different from those specified in a National Pollution Discharge Elimination System (NPDES) permit issued under Section 402 of the Federal Water Pollution Control Act (FWPCA).

See FWPCA, S 511 (c) ( 2 ), 33 U.S.C.

S1371.

This portion of CAND's contention should therefore be rejected.

Contention 7 (Low Susquehanna River Flow)

This contention asks the NRC, together with the Susquehanna River Basin Commission (S RSC) and the U. S. Army Corps of Engineers, to direct Applicants to build a reservoir to augment flow of the Susquehanna River during low fici periods.

The contention also claims that such a reservoir should be constructed prior to licensing of the facility, that Applicants "should not be permitted to possibly intimidate any government licensing ccmmission" cn low ficw augmentation, and that Applicants should be barred from claiming water rights from existing reservoirs dedicated to drinking water use and under the jurisdiction of the Pennsylvania Public Utility Ccmmission.

Applicants respectfully submit that this contention is outside the scope of this proceeding.

Consumptive use of Susquehanna River water is governed by SRBC regulations.

13 CFR 5803.61.

These regulations require compensation for consumptive uses of water during low flow periods.

5 8 0 3.61 (b) (1).

The method of compensation is to be determined by SRBC:

Methods of compensation acceptable to the [Susquehanna River Basin] Commission will depend upon the character of the project's source of water supply and other factors noted below.

5 8 03. 61 (c) (1).

Thus, it is the responsibility of SRBC, not o f NRC, to determine whether there should be a reservoir built, and if so what kind.

And, if there are no "consump-tive uses of water during periods of low flow", using the language of 58 0 3. 61 (b) (1), then no compensation is required.*

Thus, construction of a reservoir is not needed to cceply with SRBC regulations.

Applicants are, of course, bound by SRBC regulatior' and requirements.

The argument that NRC should direct how SRBC will carry out its responsibility does not raise an issue properly before this Licensing Board.

The passing reference in the contention to "an adequate supply of water.

for emergency cooling purposes" dces not contain sufficient information to allow for admission as an issue.

In any event, the Susquehanna facility does not rely at all on water from the Susquehanna River fo : : cuaency cooling purposes, but rather on :nc c..

.u

spray pond.

See Environmental Report, S3.4.6.

  • Cpera:Ing a nuclear plant in this mode, i.e.

reducing or stopping consumptive use during low flow periods, was specifically recog-nized in Philadelphia Electric Co. (Limerick Generating Station, Units 1 and 2), ALAB-262, 1 NRC 163 (1975).

J Contenrion 8 (Decommissionina)

This contention asserts that NRC, before issuing oper-ating licenses for the Susquehanna units, must (1) determine which method will be used for the eventual decommissioning of the facility, (2) establish escrot, financing for the selected mode, and (3) develop a "concingency decommissioning plan" to provide for decommissioning the Susquehanna facility "semetime within the next few years."

Applicants submit that these issues either challenge Commission regulations or are outside the scope of this proceeding.

The contention should therefore not be admitted.

Current regulations require either that the applicant pos-sesses or has reasonable assurance of obtaining the funds to pay for permanently shutting down the facility and main-taining it in a safe condition.

10 CFR 55 0. 3 3 (f ), and Appendix C, SI.B.

The procedures for decommissioning are set forth in 10 CFR 550.82, which provides that information on the methods for decommissioning is to be submitted in connection with an application to dismantle the facility.

Thus, the issucs which CAND would litigate are in direct conflict with Commission regulations.

That CAND's assertions go beyond what Ccmmission regula-tions currently require is pointed out most clearly by the Ccmmission's consideration of changes in existing rules.

On March 13, 1978, the Ccmmission published in the Federal Register an Advance Notice of Proposed Rulemaking on decc= mis-

- 14 sioning criteria for nuclear facilitie.

43 Fed. Reg. 10370 (1978).

This notice stated:

The Commission is considering development of a more explicit overall policy for de-commissioning nuclear facilities and amending its regulations in 10 CFR Parts 30, 40, 50 and 70 to include more specific guidance on decommissioning criteria for production and utilization facility li-Censees The questions to which the Commission invited comment included 1.

Is it desirable to develop more definitivo decommissioning criteria for production and utilization facility licensees

?

2.

Should detailed decommissioning plans be required prior to issuance of licenses?

3.

Should funding or other surety arrange-ments be required before the issuance of licenses for all cases?

If not, which cases?

Thus, the very questions which CAND seeks to litigate in this proceeding are, in the Commission's view, beyond the scope of present regulations.

It should also be noted that a petition filed by Public Interest Research Group, et al.

on July 5, 1977, requested NRC to modify its regulations to require escrow financing of future nuclear power plant decommissioning.

See Dccket No. PRM-50-22, Public Interest Research Group--Filing of Petition for Rulemaking, 42 Fed.

Reg. 40063 (August 8, 1977).

This rulemaking proceeding is still in progress.

Contention 9 (Evacuation Plans)

This contention asserts that Applicants' emergency plans must provide realistic logistical transportation assis-tance for the tens of thousands of hospital-ized and institutionalized persons in nursing homes and mental treatment facilities, as well as the physically and mentally handi-capped within a fifty mile radius of Salem Township.

The contention also includes the claim that the " instruments to track radioactivity much beyond the Salem Township atomic plant site" are inadequate.

Applicants would not object to the admission of these two assertions as issues in this proceeding.

While prior Commission decisions had concluded that evacuation plans beyond the low population zo"e were not to be considered in licensing proceedings, Ny Encland Power Co. (NEP Units 1 and 2), ALAB-390, 5 NRC 733 (1977), the Commission has rejected this interpretation.

See Notice of Proposed Rule-making, 43 Fed. Reg. 37473 (1978) in which the Commission has directed that a proposed admendment to 10 CFR Part 50, Appendix E, be used as interim guidance.

That proposed amendment provides that the extent of emergency planning beyond the low population zone should depend on facility design features, site characteristics, and appropriate emergency protection action criteria.

See also Detroit Edison Ccmpany, et al. (Enrico Fermi Atomic Power Plant, Unit 2),

Docket No. 50-341, Decision of the Atomic Safety and Licensing Scard dated January 2, 1979 at 12.

Contention 10 (Radiation Studies)

This contention asserts that Applicants, in conjunction with EPA and state agencies, should be directed to study "the link between low-level radiation and disease, such as cancer, on the human inhabitants" of the area around the Susquehanna facility.

The contention woi 'd also require annual testing of all school children within a fifty mile radius of the plant.

It appears that this contention is not raising the issue of health effects of low level radiation per se.

(That issue is specifically addressed in CAND's Contention 15.

To the extent that this contention seeks to raise the health effects question,s Applicants note that they have no objection to the admission of this issue as raised by Conten-tion 15.)

Rather, the contention appears to argue that basic research is needed, "to scientifically evaluate the effects of low-level radiation on humans Such a contention raises no issues specific to the Susquehanna facility.

What is more, it would seem tc challenge NRC and EPA regulations governing radiological releases from nuclear power plants.

Both NRC's regulations in Appendix I to 10 CFR Part 50 and EPA's rules in 40 CFR Part 190 1ke into account the health effects to hcnans which could be caused by releases of radioactive effluents at the levels con-templated by the rules.

See, e.g.,

In the Matter of Rule-makinc Hearing, Docket No. RM-50-2, CLI-75-5, 1 NRC 277 at 298, 311, 315-318 (1975); NRC Decision Not To Conduct a Hearing to Refine or Reduce the Health Cost Figures Pre-viously Adopted, 43 Fed. Reg. 22253 (1978).

The extensive rulemaking proceedin<gs which resulted in the two rules explored the calculated health effects which could be exp.cted from the release levels.

Thus, the thrust of the contention that scme form of " systematic human physical examinations" are necessary to show what health effects will be caused by radiological releases is a quarrel with the underlying bases of the regulations themselves.

The conten-tion should therefore not be admitted.

Contention 11 (Inadequate Construction Monitoring)

In this contention, CAMD refers to a report of the General Accounting Office (GAO) related to NRC's monitoring of nuclear power plant construction.*

Based en the observations in this report, CAND requests that the Cctmission re-examine inspection records with regard to a number of construction elements for the Susquehanna ;1 ant and re-examine "the structural placement" of "all

. vital components necessary for the proper containment c. radioactivity.

Applicants submit that CAND's statements and observations do not constitute an admissible contention.

'Though CAND does not state the specific GAO report about which it is concerned, Applicants assume this contention is a reference to a report of September 7, l>72, titled "The Nuclear Regulatory Commission Needs to Aggressively Monitor and Independently Evaluate Nuclear Powerplant Construction."

CAND's statement dces not relate specifically to the Susquehanna project.

CAND provides no information indicating the existence of any deficie.tcies in the construction of the Susquehanna facility.

Nor does the GA0 report on which the contention relies make any reference to this f acility.

Applicants' FSAR provides a detailed description of the quality assurance program for the Susquehanna project.

See FSAR, ch. 17.

The contention hc; not asserted any specific (or even any general) criticisms of that program.

The contention, in fact, appears to acknowledge that Applicants' quality assurance program has properly functioned in that the program has discovered instances of " defective manu-facture and assemblage, etc. of major components.

Absent some specific, supported allegation that instances of

" defective manufacture and assemblage" have not been dis-covered or corrected, the contention should be denied.

Contention 12 (Transportation of Nuclear Fuel)

This contention states that because the railroad bed and track over which fuel shipments to the Susquehanna plant will travel have deteriorated, Applicants should not be permitted to receive fuel shipped by rail until all readbeds and trackage are rebuilt.

CAND in this contention appears to express a concern that existing rail conditions pose a hazard because of possible rail accidents.

The concern that existing rail conditions pose a hazard is thoroughly addreased in several parts of the Commission regulations.

This contention is a challenge to such regula-tions and should not be admitted.

It is not completely clear whether the centention deals

.y with transportation of fuel to the plant site (i.e.

ot.

transportation of unirradiated, fresh fuel) or with transportation of fuel to and from the site (i.e. transportation of unirradiated and of spent fuel).

  • In either case, the subject matter of the contention is covered by Commission regulations responsive to the concern expressed.

The environmental impacts of transporting fresh and spent fuel are specified in 10 CFR Part 51, Table S-4.

These impacts include those from trans-portation accidents as well as the exposure to transportation workers and the general public.

Thus, the environmental impacts of fuel transportation are covered by Ccamission regulation and cannot be litigated in individual licensing proceedings.

See, e.g.

Kansas Gas and Electric Co. (Wolf Creek Generating Station, Unit No. 1), Ll?-75-33, 1 NRC 618, 619-620 (1975).

Implicit in CAND's contention is the assertion that a nuclear fuel cask involved in a train accident would be damaged.

Mcwever, such casks are required by Cctmissicn

  • To the extent enat the contention is intended to apply to fresh fuel, it lacks any basis since, as stated in Applicants' Environmental Report, fresh fuel is to be shipped to the Susquehanna facility by truck, not by rail.

Environmental Report, 53.8 regulations to be designed in a manner to avoid damage even in severe accident situations.

(See 10 CFR Part 71)

Specific accident requirements are summarized in 10 CFR 571.36 and Appendix 3 to Part 71 of the Ccmmission regulations.

Additionally, in 49 CFR Part 173, there are further regulations that deal with the manner of shipment and packaging of radioactive material.

The specific regulations relating to rail shipment are found in 49 CFR Part 174.

Such conten-tion is a challenge to these regulations, and therefore should not be admitted in the proceeding.

Contention 13 (Spent Fuel Storage)

In this contention, CAND argues that the Commission should establish a moratorium on the granting of nuclear power plant operating licenses until "the entire issue over nuclear waste disposal is settled by the government and industry."

The Ccmmission has already rejected this asser-tien in its denial of a petition for rulemaking and that denial has been judicially affirmed.

For this reason, the contention should not be admitted.

On November 8, 1976, the Natural Resources Defense Council (NROC) filed a petition for rulemaking (Occket No.

PRM-50-13) requesting that the NRC cease issuing operating

. censes until it made a " definitive safety finding" cn the nuclear waste disposal issue.

That rulemaking petition was denied by the Commission on July 5, 1977, on the grounds that such a request was inconsistent with statutes, regula-tions and Commission policy. See 42 Fed. Reg. 34391 (1977).

Subsequently, the NRDC appealed the Commission decision to the U.

S.

Court of Appeals for the Second Circuit.

The Court upheld the NRC action and said:

. NRC is not required to conduct the rulemaking proceeding requested by NRDC or to withhold action on pending or future ap-plications fcr nuclear power reactor oper-ating licenses until it makes a determination that high-level radioactive wastes can be permanently disposed of safely NRDC v. NRC, 582 F.2d 166 (2nd Cir. 1978)

Thus, the request for a r!.oratorium, which is called for in this contention, has already been rejected by the Commis-sion and the courts.

Such contention is a challenge to those rulings, and therefore should not be admitted.*

Contention 14 (Transmission Line Impacts)

CAND in this contention makes a series of assertions about impacts from high voltage transmission lines.

These impacts include noise pollution, electrical shocks, tele-vision and radio interference, electrostatic and electro-magnetic fields, ozone levels, and others.

Applicants do not object to the admission of a conten-tion on these concerns about potential impacts of transmis-sion lines.

However, Applicants would oppose the admission

" Applicants note that Paragraph 1.3 of the Supplement to Pen; tion for Leave to Intervene of Colleen Marsh, et al. raises an issue en the ability to safely store spent fuel and low-level radio-active wastes.

Applicants have raised nc objection to this con-tention.

If the Marsh centention is admitted, CAND may partici-pate in litigation of this issue in accordance with NFC practice.

22 -

of a contention related to CAND's statement that the trans-mission lines should be built underground.

Applicants' opposition to the consideration of a proposal that the lines be placed underground is based on the principle, now well established both in the courts and before the Commis-sion, that NEPA is applied with a " rule of reason" for the range of alternatives that must be considered.

Important court cases articulating this legal principle are Natural Resources Defense Council v. Morton, 458 F.2d 827, 834-36 (D.

C. Cir. 1972); Carolina Environmental Study Group v.

U.

S.,

510 F.2d 796, 798 (D.

C.

Cir. 1975); Scientists' Institute for Public Information, Inc. v. AEC, 481 F.2d 1079, 1092 (D.

C.

Cir.

1973).

The principle is also adopted by the Commission in Northern States Power Company (Prairie Island Nuclear Generating Plant, Units 1 a: d 2) and Vermont Yankee Nuclear Power Corpora-tion (Vermonr Yankee Nuclear Power Station), ALA3-455, 7 NRC 41, 1978.

Applicants believe that the application of NEPA at the operating license stage under a rule of reason precludes con-sideration n an alternative that is inconsistent with already const3ucted facilities.

Applicants are authorized, under the construction permits, to complete construcrion of overhead transmission lines.

It is an unreasonable alternative, there-fore, to consider the initiation of an entirely new and dif-ferent construction effort to place the lines underground.

NEPA case law supports the proposition that alternatives to completed projects need act be considered under the rule of reason.

For example, in Badoni v. Higginson, 455 F.Supp.

641 (D. Utah 1977), the Federal Court in considering the need for an environmental impact statement prior tc the opera-tion of a dam and reservoir, concluded that:

[t]he courts have consistently interpreted NEPA to require a consid-eration of alternatives which are reasonable and do not demand what is not meaningfully Jossible.

(citations omitted)

~

~

455 F.Supp. at 649'~~

Similarly, the Federal District Court for the Southern District of New York discussed the application of NEPA to a substantially completed Federal housing project and upheld the NEPA evaluation performed by the Department of Housing and Urban Development (HUD).

The court stated:

In reviewing HUD's weighing of the advantages and disadvantages of the appropriate alternatives, we will not turn the clock back and ccmpel the agency to disregard present realities or require HUD to pivot its decision on facts that no longer exist.

Trinity Episcopal School v.

Harris, 12 E.P..C.

1281, 1293 (S.D.N.Y. 1978).

The United States Court of Appeals for the District of Columbia Circuit in Marvland National Capital Park and Planning Commission v.

U.

S.

Postal Service, 487 F.2d 1029 (D.

C.

Cir.

1973), declined to stop cons.truction of substantially complete

24 -

~

facility, notwithstanding the absence of any NEPA review.

The Court observed:

(w] e must face the reality that the building was substantially complete as of May 1973.

487 F.2d at 1042 The appropriate time to raise the question of how the transmission lines should be built was before construction was authorized.

Cases have held that no environmental review is needed if the f acility has already been completed.

See, e.c.

Save Our Wetlands v.

U.

S.

Army Corps of Encineers, 549 F.2d 1021 (5th Cir. 1977).

Other cises hold that a project which has been completed would not be reassessed even where the original environmental review was inadequate.

See, e.g. Oguncuit villace Corp. v.

R.

M.

Davis, 553 F.2d 243 (1st Cir. 1977).

In this proceeding, environmental review of the transmission lines was completed at the construction permit stage.

Reopening that decision after construction has been authorized and sub-stantial construction completed would be, we believe, inappropri-ate.

See Detroit Edison Company, et al. (Enrico Fermi Atomic Power Plant, Unit 2), Docket No. 50-341, Decision of the Atomic Safety and Licensing Board dated January 2, 1979 at 24-24a.

For the reasons stated above, the aspect of this contention related to constructing underground treasmission lines should not be admitted.

Contention 15 (Health Effects of Lcw-Level Radiation)

In this contention, CAND makes a series of assertions about the alleged adverse health consequences of Icw-level radiation, which CAND believes may be emitted frcm the

Susquehanna plant.

Applicants do not object to the admis-sion of this contention, and will present evidence to demon-strate that none of the alleged health ef fects of low-level radiaticn will occur as a result of plant operation.

Contention 16 (Shipment of Hichiv Enriched Uranium to Rumania)

This contention does not appear to relate to the operating license proceeding for Susquehanna.

CAND appears to express its concern in this contention about the security related to weapons grade uranium (highly enriched uranium).

The fuel that will be used in tne Susquehanna plant, like that used in other light water power reactors, is not enriched beyond a level of four percent.

Thus, concerns about highly enriched ur:nium are not relevant here.

CAND's contention appears to relate to national security issues and not to the operation of Applicant's commercial nuclear facility.

Applicants therefore respectfully request that this contentisn not be admitted.

CONCLUSION For the reasons set forth above and in Applicants' September 21, 1979 Answer to " Petition for Leave to Intervene" submitted by Citizens Against Nuclear Dangers Applicants respectfully sub-mit that Citizens Against Nuclear Dangers, snould be admitted as an intervenor in this proceeding and that elements of the pro-posed contentions as specified abcVe should be admitted as the

- 26 contentions of Citizens Against Nuclear Dangers.

Respectfully submitted, SHAW, PITTMAN, POTTS & TRCWERIDGE By M

/s r

Jay s.

Silberg Ala IR. fuspeh Counsel for Applicants 1800 M Street, N. W.

Washington, D.

C.

20036 (202)331-4100 Dated:

January 26, 1979

UNITED STATES OF AMERICA NUCLEAR REGULATORY CCMMISSION Before the Atomic Safety and Licensina Board In the matter of

)

)

PENNSYLVANIA POWER AND LIGHT COMPANY )

and

)

Docket Nos. 50-387 ALLEGHENY ELECTRIC COOPERATIVE, INC. )

50-388

)

(Susquehanna Steam Electric Station, )

Units 1 and 2

)

CERTIFICATE OF SERVICE This is to certify that copies of the foregoing

" Applicants' Response to Supplements to Petition for Leave to Intervene of Citizens Against Nuclear Dangers" were served by deposit in the U.S.

Mail, first class, postage prepaid, or by hand, this 26th day of January, 1979, to all those on the attached Service List.

b hf Alan R.

Yuspeh Dated:

January 26, 1979

UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING ECARD In the Matter of

)

)

PENNSYLVANIA POWER & LIGHT COMPANY

)

Docket Nos. 50-387 and

)

50-388 ALLEGHENY ELECTRIC CCOPERATIVE, INC.

)

(Susquehanna Steam Electric Station,

)

Units 1 and 2)

)

SERVICE LIST Secretary of the Commission Docketing and Service Section U.

S.

Nuclear Regulatory Commission Office of the Secretary Washington, D.

C.

20555 U.

S. Nuclear Regulatory Commission Washington, D.

C.

20555 Charles Bechhoefer, Esquire Chairman Dr. Judith H.

Johnsrud Atomic Safety and Licensing Co-Director Board Panel Environmental Coalition on U.

S.

Nuclear Regulatory Commission Nuclear Power Washington, D. C.

20555 433 Orlando Avenue State College, Pennsylvania 16801 Mr. Glenn O.

Bright Atomic Safety and Licensing Susquehanna Environmental Advocates Board Panel c/o Gerald Schultz, Esquire U.

S.

Nuclear Regulatory Commission 500 South River Street Washington, D.

C.

20555 Wilkes-Barre, Pennsylvania 18702 Dr. Oscar H.

Paris Mrs. Irene Lemanowicz, Chairman Atomic Safety and Licensing The Citizens Against Nuclear Danger Board Panel Post Office Box 377 U.

S.

Nuclear Regulatory Ccmmission R.

D.

1 Washington, D.

C.

20555 Berwick, Pennsylvania 18603 Atomic Safety and Licensing Ms. Colleen Marsh Board Panel 558 A, R.

D.

44 U.

S.

Nuclear Regulatory Commission Mt. Top, Pennsylvania 18707 Washington, D.

C.

20555 Mr. Thomas M.

Gerusky, Director Atcmic Safety and Licensing Appeal Bureau of Radiation Protection Scard Panel Department of Environmental Resources U.

S.

Nuclear Regulatory Commission Commonwealth of Pennsylvania Washington, D.

C.

20555 P.

O.

Box 2063 Harrisburg, _L;nnsylvania 17120 James M.

Cutchin, IV, Esquire Office of the Executive Legal Director U.

S.

Nuclear Regulatory Commission Washing:cn, D.

C.

20555