05000293/LER-1979-044, Forwards LER 79-044/03L-0

From kanterella
(Redirected from ML19262A973)
Jump to navigation Jump to search
Forwards LER 79-044/03L-0
ML19262A973
Person / Time
Site: Pilgrim
Issue date: 12/06/1979
From: Mcguire P
BOSTON EDISON CO.
To: Grier B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML19262A974 List:
References
79-259, NUDOCS 7912110370
Download: ML19262A973 (1)


LER-1979-044, Forwards LER 79-044/03L-0
Event date:
Report date:
2931979044R00 - NRC Website

text

.

/

' Etilson.::w.,

P. ; m ' ' VA E vi P C J. E s S r ', r

  • i.D'1 4 0C. r. h t L.i. sd

.h_ 'r ' N T 4,.'.l A f.' E HL L E T T "

- J}

December 6, 1979 BECo Ltr. #79-259 Director, Region I Office of Inspection and Enforcement U. S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, PA 19406 Licensee Event Report 79-044/03L Docket Number 50-293 License DPR-35 Gentlemen:

The attached Licensee Event Report 79-044/03L, Leak Detection Air Sampler, is hereby submitted in accordance with the requirements of Pilgrha Nuclear Power Station Technical Specification 6.9.B.

The Operations Review Committee haa reviewed this event and classified it as operation in a degraded mode per-mitted by a Limiting Condition for Operation (Specification 6.9.B.2.b).

If there are any questions on this subject, please contact us.

Respectfully sub nitted, W'Y P. J. McGuire Station Manager Nuclear Operaticns CJM/dmh Enclosures: (3 copies)

LER 79-044/03L cc:

Director (40 copies)

Office of Management Information and Program Cor trol U. S. Nuclear Regulatory Commission Washington, D. C.

20555 1528 310 79121 10 [ O t

.3