05000293/LER-1979-042-03, /03L-0:on 791101,oxygen Analyzer Valves A0-5065- 10,12,15,16,17,23 & 26 Did Not Meet Primary Containment Isolation Timing Requirements.Caused by Faulty Position Indication Lights on A0-5045-12 & 15

From kanterella
(Redirected from ML19260B192)
Jump to navigation Jump to search
/03L-0:on 791101,oxygen Analyzer Valves A0-5065- 10,12,15,16,17,23 & 26 Did Not Meet Primary Containment Isolation Timing Requirements.Caused by Faulty Position Indication Lights on A0-5045-12 & 15
ML19260B192
Person / Time
Site: Pilgrim
Issue date: 11/30/1979
From: Mathis C
BOSTON EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML19260B188 List:
References
LER-79-042-03L, LER-79-42-3L, NUDOCS 7912070393
Download: ML19260B192 (1)


LER-1979-042, /03L-0:on 791101,oxygen Analyzer Valves A0-5065- 10,12,15,16,17,23 & 26 Did Not Meet Primary Containment Isolation Timing Requirements.Caused by Faulty Position Indication Lights on A0-5045-12 & 15
Event date:
Report date:
2931979042R03 - NRC Website

text

(7 77)

LICENSEE EVENT REPOhT

, CONTROL BLOCK: l l

l l

l l lh (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION) i e

[o'TT1 1 M I A I P l P l S l 1 l@l 0 l 0 0l0l0l0l0l0 0l0 0l@l4l1 1l1l1l@l l

l@

7 8 9 LICENSEE COOE 14 15 LICENSE NUMBER 15 26 LICENSE TYPE JO 67 CAT b8 CON'T 3$n%lLl@l0l5l01-10 2l913l@l1 1 0l1l7l91@l1l1 3l0 7l9l@

o i 7

8 60 61 DOCK ET NUMBER 68 69 EVENT DATE 74 75 REPORT DATE 80 EVENT DESCRIPTION AND PROB ABLE CONSEQUENCES h o 2 l At 0635 hours0.00735 days <br />0.176 hours <br />0.00105 weeks <br />2.416175e-4 months <br /> on November 1, 1979, Oxygen Analyzer valves A0-5065-10,12,15,16,17,23 l o 3 l and 26 did not meet the timing requirements for Primary Containment Isolation. All l o

4

[ valves were placed in the closed position and investigation commenced immediately, o s l This condition also caused the Primary Containment Atmospheric Monitor C-19 to

[

lo Is l l become inoperable.

l l0 l7l l l

0 8

l DE CODE S BC E COMPON ENT CODE SUB ODE SU E

l S l D l@ [E_j@ l B l@ lI lN S lT l Rl Ul @ y @ W @

O 9 7

8

_9 10 11 12 13 18 tw 20 SEQUENTIAL OCCURRENCE REPO4T REVISION LE R/RO EVENT YE AR REPORT NO.

CODE TYPE N O.

h guy 7 l9 l l-l l0 l4 l2 l l/

0l 31 Ll

[---J

[_0j RE

_ 21 22 23 24 26 27 28 29 30 31 32 K N A ON ON PLANT MET HOURS S8 i FOR S.

SUPPL 1 MANUFACTURER [A_j@lBl@

Zl@

l Z l@

lG 0 l0 l0 l W@

Nl@

l A l@

l M l 3 l 0 l 2 l@

33 34 35 3/

40 41 42 43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h i

O l The investigation revealed faulty positiqn indication lights on A0-5045-12. 15. and I a loose limit switch on A0-5045-26. These valves position problems were corrected I

i, yi; ;

g and timing was correct. A0-5045-17 & 23 were checked with no problems found and

timed satisfactorily. A0-5045-10 & 16 were left in the isolated position f.,r future l g repairs and the 02 Analyzer & C-19 returned to service on Nov. 2, 1979.

l 7

8 9 80 ST S

% POWER OTHER STATUS DIS O R DISCOVERY DESCRIPTION y l l@ l1 l0 l0 l@l N.A.

l lBl@l ROUTINE SURVEILLANCE l

A TIVITY CO TENT RELEASED OF RELE ASE AMOUNT OF ACTIVITY LOCATION OF RELEASE Zl l

N.A.

l N.A.

l i 6 PERSONNEL EXPOS ES NUMBE R TYPE

DESCRIPTION

l0 0l0l@lZl@l N.A.

l i 7 PERSONNE L INJURIES NUMBER

DESCRIPTION

l0 0l0l@[

l N.A.

i a 7

8 9 11 12

.I J ! /_

UJ9 so LOSS OF OR DAMAGE TO FACILtTY Q N

TYPE DESCRIP TION v

lZl@l N.A.

7912070

/

l 9

7 8 9 10 80 ISSUE @l DESCRIPTION N.A.

l l

lllllllllllj 2 0 7

8 9 10 68 69 g

80 E Charles J. Mathis 617-746-7900 o

NAME OF PREPARER PH.ON E: