05000325/LER-1979-083-03, /03L-0:on 791024,reading on Torus Level Instrument 1-CAC-LT-3342 Was Six Inches Low.Caused by Inaccurate Calibr Resulting from Debris in Sight Glass.Calibr Instruction Revised to Include Cleaning of Sight Glass

From kanterella
(Redirected from ML19256F097)
Jump to navigation Jump to search
/03L-0:on 791024,reading on Torus Level Instrument 1-CAC-LT-3342 Was Six Inches Low.Caused by Inaccurate Calibr Resulting from Debris in Sight Glass.Calibr Instruction Revised to Include Cleaning of Sight Glass
ML19256F097
Person / Time
Site: Brunswick 
Issue date: 11/14/1979
From: Tollison A
CAROLINA POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19256F095 List:
References
LER-79-083-03L-01, LER-79-83-3L-1, NUDOCS 7911210429
Download: ML19256F097 (2)


LER-1979-083, /03L-0:on 791024,reading on Torus Level Instrument 1-CAC-LT-3342 Was Six Inches Low.Caused by Inaccurate Calibr Resulting from Debris in Sight Glass.Calibr Instruction Revised to Include Cleaning of Sight Glass
Event date:
Report date:
3251979083R03 - NRC Website

text

U.S. NUCLEAR REGULATORY COMMISSION NRC PORM 366 87 77)

LICENSEE EVENT REPORT CONTROL BLOCK: l l

l l

l l lh (PLEASE PRINT OR TYPE ALL REQUIREO INFORMATION) 1 6

foTil IN lC lB lE lP l1 l@l0 l0 l-l0 l0 l0 0 l0 l-l0 l0 lgl4l1l1l1l1lgl l

g 7

8 9 LlOENSEE CODE 14 15 LICENSE NUMBER 25 25 LICEN4E T ' PE 40 57 CAT $8 CON'T L h l 0l5 l 0l -l Ol 3l 2l 5 @ l ll Ol 2l 4l 7l 9 @ l l

l l

l l

l@

$ouRCE 7

8 60 61 OOCK ET NUMB ER 68 69 EVENT DATE 74 75 REPORT DATE 80 EVENT DESCRIPTION AND PROB ABLE CONSEQUENCES h Lo_Ld l During a normal surveillance tour of the Reactor Building, the auxiliary operator Al noticed that the torus level instrument 1-CAC-LT-3342, on the remote shutdown panel, l

was reading six inches low.

o 4

l Io TTI l i

LE LsJ l l

O 7

l F51T1 i Technical Specification 3.3.5.2, 6.9.9.b l

80 OE CODE SUSC DE COMPONENT CODE SUS DE SU E

lIl E l@ W@ l A l@ l Il Nl S l Tl Rl U l@ {Q lZ g o

9 7

8 9

10 11 12 13 18 19 20 SEQUENTIAL OCCURRENCE REPORT REVISION EVENT YEAR REPORT NO.

CODE TYPE NO.

@,a'E R/R0l 71 ol

- l 0 8l 3l y

l0l3 l Lj g

l0l L

uNEj a

21 22 23 24 26 27 28 22 30 31 J2 K N AC N

ON PL NT ME HOURS 22 S8 i POR 8.

SUPPLIER MANUPAC RER l X l@lC l@

l Z l@

l Zl@

l 0] 0l 0l l

Qg l Y [g l3Alg l R 3 l 6 l 9 lQ 33 34 3%

36 37 40 41 42 4

44 47 CAU3E DESCRIPTION AND CORRECTIVE ACTIONS i

O l CAC-LTI-3342 had been calibrated inaccurately due to an erroneous sight glass reading. l The temporarv sight glass contained debris. The sight glass was replaced and the

]

i i g

instrument was recalibrated and returned to service. The calibration instruction has; yl been revised to include a check of the sightglass for cleanliness before calibration l L'E l begins and to verify sighe glass level before and after calibration.

(Cont'd) l 80 7

8 9 STA

% POWER OTHER STATUS 015 O RY DISCOVERY DESCRIPTION NA l

lAlglOperatorSurveillance l

Q W @ l0l0l0l@l A T1VITY CO TENT nELEASE AMOUNT OP ACTIVITY LOCATION OP RELEASE M d @D OP RE' EASE [,Z,,,,,,j@ l NA l

l NA l

7 8 9 10 11 44 45 80 PERSONNEL EXPOSURES NUV8E R TYPE

DESCRIPTION

NA l

ITT71 l 0101 Ol@W@l So PERSO~~E'L,~3u'4 ES oESCRiPfiON@

t )7 /Q lu (

suuSER I

' J

'l / J W l 0l 0 0l@l NA 7

8 9 11 12 80 LOSS OF OR DAMAGE TO PACILITY TYPE

DESCRIPTION

lZ l@l NA t 9 7

8 9 10 7911210 # 9 NaC uSe ONov ISSUEf@l DESCRIPTION N

NA l

llllllllllllll 2 o 68 69 80 ~.

7 8 9 to 919 l*57 05?1

);

A. C. Tollison, Jr.

PHONE:

NAME OF PREPARER

LER CONTINUATION -- RO# 1-79-83 Facility: BSEP Unit #1 Event Date 10-24-79 An Engineering Work Request has been written to install a permanent sight glass.

13/$ J94 h

e