05000325/LER-1979-049-03, /03L-0 on 790724:drywell 0-2 Monitor Air Dryer Showed -1259 Reading During Normal Operation After Routine Preventive Maint.Caused by Ice Buildup on Chiller Coils Resulting in Reduced Sample Flow

From kanterella
(Redirected from ML19207B323)
Jump to navigation Jump to search
/03L-0 on 790724:drywell 0-2 Monitor Air Dryer Showed -1259 Reading During Normal Operation After Routine Preventive Maint.Caused by Ice Buildup on Chiller Coils Resulting in Reduced Sample Flow
ML19207B323
Person / Time
Site: Brunswick Duke Energy icon.png
Issue date: 08/21/1979
From: Tollison A
CAROLINA POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19207B319 List:
References
LER-79-049-03L-01, LER-79-49-3L-1, NUDOCS 7908240412
Download: ML19207B323 (2)


LER-1979-049, /03L-0 on 790724:drywell 0-2 Monitor Air Dryer Showed -1259 Reading During Normal Operation After Routine Preventive Maint.Caused by Ice Buildup on Chiller Coils Resulting in Reduced Sample Flow
Event date:
Report date:
3251979049R03 - NRC Website

text

o (7 77)

LICENSEE EVENT REPORT

. CONTROL BLOCK:

l l

l l

l l

(PLEASE PRINT OR TYPE ALL REQUIRED INFORMATIONI 1

6 foTil N C Ia la ir 11 I@l 0101 -10101010101 -1010l@l 4111111 1 @l I@

7 8 9 LICENSELCODE 14 15 LICENSE NUMBER 25 26 LICENSE TYPE 30 5 7 C A.* $8 CON'T lL@l0 5 l 0 l - l 0 l 3 l 2 l 5 @l O l 71 2 l 4 l 7 l 9 l@l 0 g 8 l 2 ) 1 l 7 9g 0

1 SOuRC 7

8 60 61 DOCKET NUMBER 6d 69 EVENT DATE 74 75 REPORT DATE 80 EVENT DESCRIPTION AND PROBABLE CONSEQUENCES h o

2 lDuring normal operation after routine preventive maintenance had been performed on theI o

3 ldrywell 07 monitor CAC-ATH-1259 air dryer, the operator noticed that the -1259 reading l o

4 [was erratic. A check of the instrument indicated low sample f'.ow.

I O

5 l Technical Specification 3.6.6.4, 6.9.1.9b 0

6 l

l 0

7 l

l 0

8 l

l 7

8 9 80 SYSTEM

CAUSE

CAUSE COMP.

VALVE CODE CODE SUBCODE COMPON ENT CODE SUSCODE SU8 CODE b9 l Sl El@ l Dl@ W@ l A lIlR lD lR lY l@ lZ @ J@

7 8

9 10 11 12 13 18 19 20 SEQUE NTI A L OCCURRENCE REPORT REVISION LE R r RO EVENT YEAR REPORT NO.

CODE TYPE NO.

@,R E g l217l9 l-l l_0l4l9l l/l l013 l l Ll l-l l0 l 22 23 24 26 27 28 29 30 31 32 KE AC 0 ONP T

ME HOURS 22 SB ITT FOR B.

SUPPLIE MANUFAC RER l X lgl4Gl@

lZ l@

lZ[@

l0l0l0pl W@

lY jg l A l@

l B l 1 l 3 l 5 l@

33 3

36 36 37 40 41 42 43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS Phile the air was secured for maintenance, moisture in the sir dryer condensed on the I i

o

[ inner surface of the chiller coils and froze when the drver was energized. As more I

i i

,, ;,i jmoisture passed through the chiller, a larger ice buildup resulted thus reducing samnlel jflow. The coils were tSaved out and the system returned to normal. A revision to the i

3 periodic maintenance procedure is being written to purge the dryer coils before (CON'T)1 i

4 7

8 9 80 ST

% POWE R OT14ER STATUS IS O 6RY OfSCOVERY DESCRIPTION R lE l@ l 0 9 l 9 l@l NA l

W@l Operator Surveillance l

A TtVITY CO TENT RELEASED OF RELEASE AMOUNToF ACTIVITY LOCATION OF RELEASE [Zj @

l NA l NA l

1 6

7 8 9 10 11 44 45 80 PERSONNEL EXPOSURES NUMBER TYPE

DESCRIPTION

l0l0l0l@lZ[@lNA l

1 7

~ '

~' "

PEPSONNEL INJURIES NUMBER

DESCRIPTION

l0l0l0l@lNA l

i a

7 8 9 11 12 80 LOSS OF OR DAMAGE TO SACILITY

.wD0824Offl TYPE DE SCRIP TION R lZ l@ l NA

,n" 1

8 9 10

- v 80 1

E DE CRIPTION L2_Lo_I b581 NA s'

t l

ll ll llll l lj s

7 8 9 to 68 69 80 S

~

NAME OF PREPARER PHONE:

1.ER CONTINUATION - RO# 1-79-049 Facility:

BSEP Unit No. 1 Event Date:

07-24-79 starting to insure no moisture is present.

g G f t.