W3F1-2019-0041, Submittal of Owner'S Activity Report Form for Lnservice Inspection Performed During Operating Cycle 22 / Refuel 22

From kanterella
(Redirected from ML19165A083)
Jump to navigation Jump to search
Submittal of Owner'S Activity Report Form for Lnservice Inspection Performed During Operating Cycle 22 / Refuel 22
ML19165A083
Person / Time
Site: Waterford Entergy icon.png
Issue date: 06/13/2019
From: Wood P
Entergy Operations
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
W3F1-2019-0041
Download: ML19165A083 (6)


Text

~Ente,gy Entergy Operations, Inc.

17265 RIYer Rold Killona, LA 70057-3093 Tel 504 464 3786 PIIUIWood Manager - Regulatoly Aauranca Waterford 3 W3F1-2019-0041 June 13, 2019 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555

Subject:

Submittal of Owner's Activity Report Form for lnservice Inspection Performed During Operating Cycle 22 / Refuel 22 Waterford Steam Electric Station, Unit 3 Docket No. 50-382 Renewed Facility Operating License No. NPF-38 Attached is the subject report which covers the Owner's Activity Report Form, OAR-1, for Waterford 3 Operating Cycle 22 / Refuel 22, enclosed as Attachment 1. This report is being submitted In accordance with ASME Code Case N-532-5, "Repair/Replacement Activity Documentation Requirements and lnservice Summary Report Preparation and Submission,* which was adopted for use at Waterford 3 commencing its incorporation Into Regulatory Guide 1.147 and subsequent revision to CEP-RR:.001 "ASME Section XI Repair/Replacement Program* on September 10, 2018.

The OAR-1 form Is prepared and certified upon completion of each refueling outage and submitted within 90 calendar days of the completion of the refueling outage. This OAR-1 form provides: (1) a listing of items with flaws or relevant conditions that exceeded the acceptance criteria of Division 1 and that required evaluation to determine acceptability for continued service and (2) an abstract for repair/replacement activities that were required due to an item containing a flaw or relevant condition that exceeded Division 1 acceptance criteria. A copy of this letter and the attached report Is also being submitted to the office of the Louisiana State Fire Marshall.

There are no new commitments contained in this submittal.

Please contact Paul Wood, Regulatory Assurance Manager, at (504) 464-3786 should you have any questions regarding this submittal.

Respectfully, PW

Attachment:

1. Owner's Activity Report for lnservlce Inspection Performed During Operating Cycle 22/ Refuel 22

W3F1-2019-0041 Page 2 cc: NRC Region IV Regional Administrator NRC Senior Resident Inspector-Waterford 3 NRC Project Manager - Waterford 3 Mr. H. "Butch" Browning, Jr.

Office of the State Fire Marshall 8181 Independence Blvd.

Baton Rouge, LA 70806

ATTACHMENT 1 To W3F1-2019-0041 Owner's Activity Report for lnservice Inspection Performed During Operating Cycle 22 / Refuel 22

CASES OF ASME BOILER AND PRESSURE VESSEL CODE FORM OAR-1 OWNERS ACTIVITY REPORT.

Report Numbor Cyclo 22 / Refuel 22 Plant Waterford Stoam Elecbic Station, 17265 River Road, Klllona, La. 70057 Unit No. -=3------- Commorclal service date -'-08"'/2=-"4/'"'1_98""5'"-------- Refuollng outago no. 22 (lf oppllc:oblo)

Curront Inspection lntorval -=-3'-"rd'-----------------"7'.:=::-:=:-,:-:-.,----------------- -

( 1*.2"' S" 4"', other)

Curront lntpocllon porfod 3rd Edition and Addenda of Section XI oppllcablo to tho lnapoctlon piano 2001 Edition Through 2003 Addenda, 2007 Edition Through 2008 Addenda Date and nivlalon of Inspection plans 4/27/2017 Revision 006 SEP-ISl-104 Edltlon and Addonda of Soctlon XI appllcablo to repelr/replacemenl octlvlti.a, If different than the Inspection plana Same as above Code Caa1111 used: __ N-532......,_-5

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _-;;: 1f.::::=cabla=-.-------------------

1 CERTIFICATE OF CONFORMANCE I certify that (*) tho statements mado In this repor1 an1 corroet, (b) the examlnatlona and teats meet tho ln1pctetlon Plan ea roqulrod by c--_,

tho ASME Codo,Section XI, and (c) tho n,palr/ropla~ment actlvltlus and evaluations eupportlng the completion of -:ccRT"efv-=ei__.22.,....._..,....,,--_

confonn to the requlromonts of Section XI.

Date CERTIFICATE OF INSERVICE INSPECTION I, th9 undersigned, holding a valid <<>mmission issued by the National Board of Boiler and Prossure Vossol lnspo<;tors and the State or Province of Louisiana and employed by The Hartford Stoam Bodor Inspection and Insurance Company or Connochcut of Hartforo, CT have inspacted the It.ms deacrlbod in thla Owner's Activity Report and atato that, to the beat of my knowledgo and bolief, tho OWnor has performed all activities represonted by thia roport In Accordance wtth the niqulrements of Section XI.

By signing this certificate neither the Inspector nor hi11 employer makes any warranty, expn1saed or Implied, concerning Iha repair/

replacement ac:tlvltln and evaluation described In this report. Furthennoro, nolther tho lnspoctor nor his omployer shall be liable In any mannor for any po111onai injury or property damago or loH of any kind 11rl11ln9 from or connected with this Inspection.

P~--~ Commiulon fv(l I (;07'-l . LA t 7t; '7- ,* I<, IV Hatlonal Board, St.atio , Provln<*, and E.ndo.-. ~

r}....1:_

Dato _ _{,_j I 1 I j

CASES OF ASME BOILER AND PRESSURE VESSEL CODE TABLE 1 ITEMS WITH FLAWS OR RELEVANT CONDITIONS THAT REQUIRED EVALUATION FOR CONTINUED SERVICE Examination Category and Item Description Evaluation Description Item Number None None None

CASES OF ASME BOILER AND PRESSURE VESSEL CODE TABLE 2 ABSTRACT OF REPAIR/REPLACEMENT ACTIVITIES REQUIRED FOR CONTINUED SERVICE Description of Date Repair/Replacement Code Class Item Description Work Completed Plan Number Perform weld overlay in accordance with 1 1RC2-46RL 1A 5/23/2019 19-RR-07 EC-81233 and WSI traveler Perform weld overlay in accordance with 1 1RC2-48RL2A 5/23/2019 19-RR-08 EC-81233 and WSI traveler 3CC1 1/2-17 A1 (RCP 1A SEAL COOLER INLET Repair Pipe Leak 3 FAIL SAFE TUBING.) CR-WF3-2019-5316 6/11/2019 19-RR-02