Submittal of Owner'S Activity Report Form for Inservice Inspection Performed During Operating Cycle 19/Refuel 19
ML14224A279
Person / Time
Site: Waterford Entergy icon.png
Issue date: 08/12/2014
From: Jarrell J
Entergy Operations
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
W3FI -2014-0044
Download: ML14224A279 (7)


Text

Entergy Operations, Inc.

1 7265 River Road Killona, LA 70057-3093 En tergy Tel 504-739-6685 Fax 504-739-6698 jjarrelentergy.com John P. Jarrell Regulatory Assurance Manager Waterford 3 W3FI -2014-0044 August 12, 2014 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555

Subject:

Submittal of Owners Activity Report Form for Inservice Inspection Performed During Operating Cycle 19 I Refuel 19 Waterford Steam Electric Station, Unit 3 Docket No. 50-382 License No. NPF-38

Dear Sir or Madam:

Attached is the subject report which covers the Owners Activity Report Form, OAR-I for Waterford 3 Operating Cycle I 9 I Refuel I 9, enclosed as Attachment I This report is being submitted in accordance with ASME Code Case N-532-4, Repair/Replacement Activity Documentation Requirements and Inservice Summary Report Preparation and Submission, which was adopted for use at Waterford 3 commencing with the new Ten-Year Inservice Inspection (151) interval on June I 2008.

The OAR-I form is prepared and certified upon completion of each refueling outage and submitted within 90 calendar days of the completion of the refueling outage. This OAR-I form provides: (I) a listing of items with flaws or relevant conditions that exceeded the acceptance criteria of Division I and that required evaluation to determine acceptability for continued service and (2) an abstract for repair/replacement activities that were required due to an item containing a flaw or relevant condition that exceeded Division I acceptance criteria. A copy of this letter and the attached report is also being submitted to the office of the Louisiana State Fire Marshall.

There are no new commitments contained in this submittal.

Please contact John P. Jarrell, Regulatory Assurance Manager at (504) 739-6685 should you have any questions regarding this submittal.

Si

Attachment:

I . Owners Activity Report for lnservice Inspection Performed During Operating Cycle 19 / Refuel 19

cc: Regional Administrator RidsRgn4MaiICenternrc.gov U. S. Nuclear Regulatory Commission Region IV NRC Senior Resident Inspector Frances.Ramireznrc.gov Waterford Steam Electric Station Unit 3 Chris.Speernrc.gov U. S. Nuclear Regulatory Commission Michael.Orenaknrc.gov Mr. H. Butch Browning, Jr.

Office of the State Fire Marshall 8181 Independence Blvd.

Baton Rouge, LA 70806

Attachment I To W3FI -2014-0044 Owners Activity Report for Inservice Inspection Performed During Operating Cycle 19 I Refuel 19 3

CASES OF ASME BOILER AND PRESSURE VESSEL CODE FORM OAR-I OWNERS ACTIVITY REPORT ReportNumber CycIel9/ Refuel 19 Plant Waterford Steam Electric Station, 17265 River Road, Killona, La. 70057 Unit No. 3 Commercial service date 09/24/1985 Refueling outage no. 19 (If applicable)

Current inspection interval 3rd sd 1

n 2 t rd 4 3 th

( other)

Current inspection period 2nd

( 1st,2, 3rd)

Edition and Addenda of Section Xl applicable to the inspection plans 2001 Edition, Through 2003 Addenda Date and revision of inspection plans 3/12/14 Revision 002 SEP-lSl-104 Edition and Addenda of Section Xl applicable to repairlreplacement activities, if different than the inspection plans Same as above.

Code Cases used: N-532-4 (If applicable)

CERTIFICATE OF CONFORMANCE I certify that (a) the statements made in this report are correct; (b) the examinations and tests meet the Inspection Plan as required by the ASME Code, Section Xl; and (c) the repairlreplacement activities and evaluations supporting the completion of Refuel 19 (refueling outage number) conform to the requirements of Section Xl.

Signed Date Owner or Owners Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Louisiana and employed by HSB Global Standards of Hartford, CT have inspected the items described in this Owners Activity Report and state that, to the best of my knowledgeand belief, the Owner has performed all activities represented by this report in Accordance with the requirements of Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair!

replacement activities and evaluation described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

7

,4ti:/7 Commissions LA 1184 (A, N, I)

Inspectors Signature National Board, State, Province, and Endorsements Date 4

CASES OF ASME BOILER AND PRESSURE VESSEL CODE TABLE I ITEMS WITH FLAWS OR RELEVANT CONDITIONS THAT REQUIRED EVALUATION FOR CONTINUED SERVICE Examination Category and Item Description Evaluation Description Item Number None None None 5

CASES OF ASME BOILER AND PRESSURE VESSEL CODE TABLE 2 ABSTRACT OF REPAIR/REPLACEMENT ACTIVITIES REQUIRED FOR CONTINUED SERVICE Description of Date Repair/Replacement Code Class Item Description Work Completed Plan Number RFRMCHL000I B Replace corroded 3 (ESSENTIAL CHILLER 06/18/2013 13-RR-003 piping B)

RFRMCHL000I C Replace corroded 3 (ESSENTIAL CH ILLER 08/1 4/201 3 1 3-RR-004 piping C)

RFRMCHL000I A Replace corroded 3 (ESSENTIAL CHILLER 10/08/2013 13-RR-005 piping A)

SI MVAAA5I2 B (REACTOR COOLANT LOOP 2 HOT LEG Replace Valve 04/28/2014 13-RR-18 INJECTION CHECK VALVE) 3CCI 1/2-35 (REACTOR COOLANT Replace corroded 3 PUMP2B 04/26/2014 13-RR-019 piping SEALCOOLER INLET FAIL_SAFE_TUBING)

FW MVAAAI 861 (FEEDWATER TO SG 2 INSIDE 2 Modify drain valve 05/21/2014 13-RR-020 CONTAINMENT UPSTREAM DRAIN ISOLATION_VALVE)

FW MVAAAI85 A (FEEDWATER TO SG 2 1 INSIDE Modifyventvalve 05/02/2014 13-RR-021 CONTAINMENT VENT ISOLATION_VALVE)

FW MVAAAI85 B (FEEDWATERTO SG 2 2 INSIDE Modify vent valve 04/28/2014 13-RR-022 CONTAINMENT VENT ISOLATION_VALVE)

FW MVAAAI88 A (FEEDWATER TO SG I INSIDE CONT 2 Modify drain valve 05/03/2014 13-RR-023 DOWN STREAM DRAIN ISOLATION VALVE) 6

TABLE 2 (Continued)

ABSTRACT OF REPAIRIREPLACEMENT ACTIVITIES REQUIRED FOR CONTINUED SERVICE Description of Date RepairlReplacement Code Class Item Description Work Completed Plan Number FW MVAAAI88 B (FEEDWATER TO SG 2 INSIDE 2 CONTAINMENT Modify drain valve 04/28/2014 13-RR-024 DOWN STREAM DRAIN ISOLATION VALVE)

FW MVAAAI86I A (FEEDWATER TO SG I INSIDE 2 Modify drain valve 05/21/2014 13-RR-025 CONTAINMENT UP STREAM DRAIN ISOLATION)

MS MVAAAI24 B Rework leak at vent 2 (MAIN STEAM 05/04/2014 13-RR-027 plug ISOLATION VALVE 2)

FWRR-6021 (FEEDWATER RIGID RESTRAI NT)

& Install new pipe 3 07/24/201 3 1 3-RR-035 FWSR-345 restraints (FEEDWATER HYDRAULIC SNUBBER)

CCRR-1 I 83 (COMPONENT Replace corroded 3 05/04/201 4 1 3-RR-039 COOLING WATER base plate support RIGID_RESTRAINT)

SG MSG0002 (STEAM Plugged 4 Steam 05/02/2014 14-RR-004 GENERATOR 2) Generator tubes FWSH-1 6 2 (FEEDWATER Replace eye-rod See Note I 14-RR-006 SPRING_HANGER)

FWSR-8 A Repairweld and 2 (FEEDWATER 05/08/201 4 1 4-RR-O1 0 modify support.

SNUBBER)

Note I .) Work was completed 5/8/1 4, but material traceability was not estabhshed in accordance with Entergys processes, and therefore an NIS-2A could not be signed. CR-WF3-2014-4114 documents this issue and will resolve the condition adverse to quality.