Notice of Violation; NRC Inspection Report 05000458/2019014 and Investigation Report 4-2017-025
ML19112A197
Person / Time
Site: River Bend 
(NPF-047)
Issue date: 04/19/2019
From: John Kramer
Region 4 Administrator
To: Vercelli S
Entergy Operations
John Kramer
References
4-2017-025, EA-18-174 IR 2019014
Download: ML19112A197 (14)


Text

April 19, 2019

SUBJECT:

RIVER BEND STATION - NOTICE OF VIOLATION; NRC INSPECTION REPORT 05000458/2019014 AND INVESTIGATION REPORT 4-2017-025

Dear Mr. Vercelli:

This letter refers to the investigation completed on November 30, 2018, by the U.S. Nuclear Regulatory Commission (NRC) Office of Investigations (OI) at the River Bend Station. The purpose of the investigation was to determine whether several nonlicensed operators willfully failed to perform operator rounds as required, and whether these nonlicensed operators willfully provided inaccurate information regarding completion of required operator rounds to the licensee.

In a telephonic exit briefing on April 12, 2019, Mr. Jason Kozal of my staff informed you that the NRC was considering escalated enforcement for apparent violations involving the deliberate failure of several nonlicensed operators to perform required operator rounds, and the deliberate failure of these nonlicensed operators to ensure that information required by statute or the Commissions regulations to be maintained by Entergy Operations, Inc. (Entergy) was complete and accurate in all material respects. Mr. Kozal also informed you that we had sufficient information regarding the apparent violations and your corrective actions to make an enforcement decision without the need for a predecisional enforcement conference or a written response. You indicated that you did not believe that a predecisional enforcement conference or written response was needed and that you accept the violations on behalf of Entergy.

Based on the information developed during the investigation, the NRC determined that two violations of NRC requirements occurred. These violations are cited in Enclosure 1, Notice of Violation (Notice), and the circumstances surrounding them are described in the factual summary (Enclosure 2) and in the inspection report (Enclosure 3). In total, five nonlicensed operators deliberately failed to tour all required areas of their watch station and deliberately entered inaccurate information into the operator logs. This caused Entergy to be in violation of Title 10 of the Code of Federal Regulations (10 CFR) Part 50, Appendix B, Criterion V and 10 CFR 50.9. Therefore, these violations are categorized collectively in accordance with the NRC Enforcement Policy as a Severity Level III problem. In accordance with the NRC Enforcement Policy, a base civil penalty in the amount of $145,000 is considered for a Severity Level III problem.

Because the Severity Level III problem was associated with willful Severity Level III violations, the NRC considered whether credit was warranted for Identification and Corrective Action in accordance with the civil penalty assessment process in Section 2.3.4 of the NRC Enforcement Policy. The NRC determined that Identification credit was warranted because the violations were identified when Entergy initiated an internal review of nonlicensed operator rounds at the River Bend Station following the receipt of operating experience and identified logkeeping performance discrepancies.

Your corrective actions included: (1) disciplining the nonlicensed operators who failed to perform rounds; (2) revising procedures to require nonlicensed operators to record logs while in front of equipment; (3) requiring nonlicensed operators to make a log entry at the completion of each shift, attesting that the rounds were completed and data is correct; (4) performing quarterly audits of operator rounds for each crew; (5) requiring supervisors to perform field observations of nonlicensed operators three times per month; and (6) performing a root cause evaluation and implementing broad corrective actions to address the low standards and lack of field presence. Additional corrective actions are documented in Enclosure 3. As a result, the NRC determined that Corrective Action credit was warranted.

Therefore, to encourage prompt identification and comprehensive correction of violations, I have been authorized, after consultation with the Director, Office of Enforcement not to propose a civil penalty in this case. However, significant violations in the future could result in a civil penalty.

In Section V of the Confirmatory Order, EA-17-132/153, issued to Entergy on March 12, 2018, Agencywide Documents Access and Management System (ADAMS) Accession ML18072A191, the NRC indicated it would consider enforcement discretion for violations that meet the criteria for discretion under Section 3.3 of the NRC Enforcement Policy. Although the violation was identified by Entergy, the NRC is not exercising discretion in this instance because it was not identified as part of the corrective action for a previous enforcement action.

The NRC has concluded that information regarding: (1) the reason for the violations; (2) the corrective actions that have been taken and the results achieved; and (3) the date when full compliance was achieved is already adequately addressed on the River Bend Station docket in Enclosure 3. Therefore, you are not required to respond to this letter unless the description therein does not accurately reflect your corrective actions or your position. In that case, or if you choose to provide additional information, you should follow the instructions specified in the enclosed Notice (Enclosure 1).

In accordance with 10 CFR 2.390 of the NRCs Agency Rules of Practice and Procedure, a copy of this letter, its enclosure, and your responses, if you choose to provide one, will be made available electronically for public inspection in the NRC Public Document Room and in ADAMS, accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html. If you have any questions concerning this matter, please contact Mr. Jason Kozal of my staff at 817-200-1144.

Sincerely,

/RA/

Scott A. Morris

Regional Administrator

Docket No. 50-458 License No. NPF-47

Enclosures:

1. Notice of Violation 2. Factual Summary 3. Inspection Report 05000458/2019014

ML19112A197 SUNSI Review:

ADAMS:

Non-Publicly Available Non-Sensitive Keyword:

By: JGK Yes No Publicly Available Sensitive NRC-002 OFFICE ES/ACES TL:ACES C:DRP/C RC DD:DRP OE NAME CAlldredge MVasquez JKozal DCylkowski MHay MMarshfield SIGNATURE

/RA/

JK for

/RA/

/RA/ E

/RA/

/RA/ E DATE 4/11/19 4/11/19 4/12/19 4/12/19 4/16/19 4/17/19 OFFICE D:DRP RA

NAME AVegel SMorris

SIGNATURE

/RA/

/RA/

DATE 04/18/19 04/19/19

Enclosure 1 NOTICE OF VIOLATION

Entergy Operations, Inc.

Docket No. 50-458 River Bend Station

License No. NPF-47 EA-18-174

During an NRC investigation completed on November 30, 2018, two violations of NRC requirements were identified. In a

Inspection Report

Docket Numbers:

05000458

License Numbers:

NPF-47

Report Numbers:

05000458/2019014

Enterprise Identifier: I-2019-014-0003

Licensee:

Entergy Operations, Inc.

Facility:

River Bend Station

Location:

St Francisville, Louisiana

Inspection Dates:

December 3, 2018, to April 12, 2019

Inspector:

D. Proulx, Senior Project Engineer

Approved By:

Jason W. Kozal

Chief, Project Branch D

Division of Reactor Projects

SUMMARY

The U.S. Nuclear Regulatory Commission (NRC) continued monitoring the licensees

performance by conducting an inspection at River Bend Station in accordance with the Reactor

Oversight Process. The Reactor Oversight Process is the NRCs program for overseeing the

safe operation of commercial nuclear power reactors. Refer to

https://www.nrc.gov/reactors/operating/oversight.html for more information. NRC-identified and

self-revealed findings, violations, and additional items are summarized in the table below.

List of Findings and Violations

Failure to Perform Operator Rounds

Cornerstone

Significance

Cross-cutting

Aspect

Inspection

Procedure

Not

Applicable

Severity Level III

NOV 05000458/2019014-01

Open

EA-18-174

Not

Applicable

Not

Applicable

Based on the information developed in Investigation 4-2017-025, the NRC concluded that five

nonlicensed operators deliberately failed to tour all required areas of their watchstation in

accordance with Procedure EN-OP-115-01, Operator Rounds in violation of 10 CFR Part 50, Appendix B, Criterion V. This violation is one of two violations that are categorized collectively

in accordance with the NRC Enforcement Policy as a Severity Level III problem.

Falsification of Operator Rounds Records

Cornerstone

Significance

Cross-cutting

Aspect

Inspection

Procedure

Not

Applicable

Severity Level III

NOV 05000458/2019014-02

Open

EA-18-174

Not

Applicable

Not

Applicable

Based on the information developed in Investigation 4-2017-025, the NRC concluded that five

nonlicensed operators deliberately entered inaccurate information into the operator logs in

violation of 10 CFR 50.9. This violation is one of two violations that are categorized collectively

in accordance with the NRC Enforcement Policy as a Severity Level III problem.

MISCELLANEOUS - TRADITIONAL ENFORCEMENT

On April 19, 2017, River Bend Station management informed the NRCs resident inspectors of

anomalies identified during their review of nonlicensed operator (NLO) rounds and logs.

Specifically, in December 2016, following receipt of operating experience from another licensee,

Entergy Operations, Inc. (Entergy) initiated an internal review of NLO rounds and log keeping

performance. Based on Entergys initial reporting of discrepancies, the NRC Office of

Investigations (OI) performed an investigation of the discrepancies. The inspectors

independently reviewed the licensees and OIs investigations. The inspectors also reviewed

the licensees casual evaluation and the actions taken to address the Confirmatory Order

associated with EA-17-132 and EA-17-153, Agencywide Documents Access and Management

System (ADAMS) Accession ML18072A191. The inspectors documented the review of the

corrective actions in NRC Inspection Report 05000416/2019012, 05000313/2019014 and

05000368/2019014, 05000458/2019013, and 05000382/2019012 (ADAMS Accession

ML19094B867).

INSPECTION RESULTS

Failure to Perform Operator Rounds

Cornerstone

Significance/Severity

Cross-cutting

Aspect

Inspection

Procedure

Not Applicable

Severity Level III

NOV 05000458/2019014-01

Open

EA-18-174

Not

Applicable

Not

Applicable

Based on the information developed in Investigation 4-2017-025, the NRC concluded that five

NLOs deliberately failed to tour all required areas of their watch station, in accordance with

Procedure EN-OP-115-01, Operator Rounds in violation of 10 CFR Part 50, Appendix B,

Criterion V. This violation is one of two violations that are categorized collectively in

accordance with the NRC Enforcement Policy as a Severity Level III problem.

Description: In December 2016, following receipt of operating experience from another plant,

Entergy initiated an internal review to look for NLO rounds and log keeping performance

discrepancies. Entergys review identified multiple log taking discrepancies and reported

them to the NRC on April 17, 2017. Following receipt of this information, OI initiated an

investigation.

Entergy Procedure EN-OP-115-01, Operator Rounds, Revision 1, a quality-related

procedure for NLOs performing watchstanding rounds, Step 5.1.7, requires, in part, that

watchstanders tour all required areas of their watchstation. The NRC determined that from

August 2016 to January 2017, five NLOs failed to tour all required areas of their watchstation.

The inspectors determined that the licensees corrective actions were prompt and reasonably

comprehensive. Actions taken included:

  • Entergy terminated the NLOs it concluded had engaged in deliberate misconduct.

The NLOs it concluded had engaged in careless disregard were disciplined with

unpaid leave.

  • Procedures were revised to require NLOs to record logs while in front of equipment.
  • A requirement was added such that NLOs are required to make a log entry at the

completion of rounds attesting that they personally completed the entire set of rounds

and entered correct data. They must also discuss the results/challenges encountered

during rounds with their supervisor.

  • Quarterly audits of operator rounds were instituted for each operating crew. The

results must be communicated to the workers to reinforce the standards and

emphasize the importance of conducting and documenting proper rounds.

  • Supervisors for NLOs are now required to perform field observations of NLOs three

times per month, including observation of rounds and log taking.

Enforcement:

Significance: The ROPs significance determination process does not specifically consider

willfulness in its assessment of licensee performance. Therefore, it is necessary to address

this violation which involves willfulness using the traditional enforcement process.

Notice of Violation:

Title 10 CFR Part 50, Appendix B, Criterion V, requires, in part, that activities affecting quality

shall be accomplished in accordance with documented instructions or procedures of a type

appropriate to the circumstances.

Entergy Procedure EN-OP-115-01, Operator Rounds, Revision 1, a quality-related

procedure intended to meet this requirement for NLOs performing watchstanding rounds,

Step 5.1.7, requires, in part, that watchstanders tour all required areas of their watchstation.

Contrary to the above, from August 2016 to January 2017, watchstanders failed to tour all

required areas of their watchstation. Specifically, five NLOs failed to tour all assigned areas

of the plant during watchstanding rounds.

Enforcement Actions: This violation is one of two violations that are categorized collectively in

accordance with the NRC Enforcement Policy as a Severity Level III problem.

The staff determined that the licensee should receive credit for identification of the problem.

The licensee took voluntary action to respond to industry operating experience at a site in

another fleet (a self-monitoring effort), specifically looking for examples of improper rounds by

NLOs and inconsistent logs.

The staff determined that the licensee should receive credit for corrective actions for the

violation. The staff determined that licensee took substantive corrective action intended to

detect, correct, and deter future misconduct and implemented those actions at each site in the

Entergy fleet. Many of the corrective actions were taken in response to a Confirmatory Order

dated March 12, 2018 (ADAMS Accession ML18072A191). The implementation of these

corrective actions was reviewed and documented in NRC Inspection Report 05000416/2019012, 05000313/2019014 and 05000368/2019014, 05000458/2019013, and

05000382/2019012 (ADAMS) Accession ML19094B867).

Falsification of Operator Rounds Records

Cornerstone

Significance/Severity

Cross-cutting

Aspect

Inspection

Procedure

Not Applicable

Severity Level III

NOV 05000458/2019014-02

Open

EA-18-174

Not

Applicable

Not

Applicable

Based on the information developed in Investigation 4-2017-025, the NRC concluded that five

NLOs deliberately entered inaccurate information into the operator logs in violation of

10 CFR 50.9. This violation is one of two violations that are categorized collectively in

accordance with the NRC Enforcement Policy as a Severity Level III problem.

Description: In December 2016, following receipt of operating experience from another plant,

Entergy initiated an internal review to look for NLO rounds and log keeping performance

discrepancies. Entergys review identified multiple log taking discrepancies and reported

them to the NRC on April 17, 2017. Following receipt of this information, the NRC Office of

Investigations initiated an investigation.

The NRC requires records of NLO rounds to be complete and accurate because the NRC

uses the information in the performance of inspections to ensure that the condition of safety-

related equipment is being monitored as required by licensee procedures. The NRCs

investigation determined that from August 2016 to January 2017, the licensee failed to

maintain these required records such that they were complete and accurate in all material

respects. Specifically, five NLOs submitted operating logs for assigned plant areas which

they had not toured and which were not complete and accurate in all material respects.

The inspectors determined that the licensees corrective actions were prompt and reasonably

comprehensive. Actions taken included:

  • The licensee terminated the NLOs it concluded had engaged in deliberate misconduct.

The NLOs it concluded had engaged in careless disregard were disciplined with

unpaid leave.

  • Procedures were revised to require NLOs to record logs while in front of equipment.
  • A requirement was added such that NLOs are required to make a log entry at the

completion of rounds attesting that they personally completed the entire set of rounds

and entered correct data. They must also discuss the results/challenges encountered

during rounds with their supervisor.

  • Quarterly audits of operator rounds were instituted for each operating crew. The

results must be communicated to the workers to reinforce the standards and

emphasize the importance of conducting and documenting proper rounds.

  • Supervisors for NLOs are now required to perform field observations of NLOs three

times per month, including observation of rounds and log taking.

Enforcement:

Significance: The ROPs significance determination process does not specifically consider

willfulness in its assessment of licensee performance. Therefore, it is necessary to address

this violation which involves willfulness using the traditional enforcement process.

Notice of Violation:

Title 10 CFR 50.9 requires, in part, that information required by the Commissions regulations,

orders, or license conditions to be maintained by the licensee shall be complete and accurate

in all material respects.

Title 10 CFR Part 50, Appendix B, Criterion XVII requires, in part, that sufficient records shall

be maintained to furnish evidence of activities affecting quality. The records shall include at

least the following: operating logs and the results of reviews, inspections, tests, audits,

monitoring of work performance, and materials analyses.

Contrary to the above, from August 2016 to January 2017, the licensee failed to maintain

information required by the Commissions regulations that was complete and accurate in all

material respects. Specifically, five NLOs submitted operating logs for assigned plant areas

which they had not toured and which were not complete and accurate in all material respects.

The operating logs are required by 10 CFR Part 50, Appendix B, Criterion XVII to be

maintained by the licensee. The information was material to the NRC because the NRC uses

the information in the performance of inspections to ensure that the condition of safety-related

equipment is being monitored as required by licensee procedures.

Enforcement Actions: This violation is one of two violations that are categorized collectively in

accordance with the NRC Enforcement Policy as a Severity Level III problem.

The staff determined that the licensee should receive credit for identification of the problem.

The licensee took voluntary action to respond to industry operating experience at a site in

another fleet (a self-monitoring effort), specifically looking for examples of improper rounds by

NLOs and inconsistent logs.

The staff determined that the licensee should receive credit for corrective actions for the

violation. The staff determined that licensee took substantive corrective action intended to

detect, correct, and deter future misconduct and implemented those actions at each site in the

Entergy fleet. Many of the corrective actions were taken in response to a Confirmatory Order

dated March 12, 2018 (ADAMS Accession ML18072A191). The implementation of these

corrective actions was reviewed and documented in NRC Inspection Report 05000416/2019012, 05000313/2019014 and 05000368/2019014, 05000458/2019013, and

05000382/2019012 (ADAMS) Accession ML19094B867).

EXIT MEETINGS AND DEBRIEFS

On April 12, 2019, the NRC staff presented the inspection results to Mr. S. Vercelli, Site Vice

President, and other members of the licensee staff in a telephonic exit meeting. The NRC staff

verified no proprietary information was retained or documented in this report.