ML18079A501

From kanterella
Jump to navigation Jump to search
LER 79-047/03L-0 on 790531:during Refueling Core Shuffle,Six Control Rod Spider Fingers Affecting Eight Control Rodlets Found to Be Broken.Cause to Be determined.Twenty-five Rods in Rod Cluster Control Assembly Replaced
ML18079A501
Person / Time
Site: Salem PSEG icon.png
Issue date: 06/30/1979
From: Kapple A
Public Service Enterprise Group
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML18079A500 List:
References
FOIA-81-159 LER-79-047-03L, LER-79-47-3L, NUDOCS 7907090277
Download: ML18079A501 (2)


Text

NRC FORl'11 366 U.S. NUCLEAR REGULATORY COMMISSION 17-771 LICENSEE EVENT REPORT CONTROL BLOCK: f f0 CPLEASE PRINT OR TY,E ALL REQUIRED INFORMATIONI 1 e ITI2] INl.11 sl Glsl1l0J d ol 01010101010 I 01010101411111111101 I I@

7 8 9 LICENSEE CODE 14 ,5 LICENSE NUMBER ~S 26 LICENSE TYPE ;JO 57 CAT 58 CON'T ITIIJ 1 . II

~~! Lk.J©I 0151010 I Of 2f 712 K!)IO I Sf 3J ll 7 !9 @10 16 I 31Df7 f9 IG) 80 61 DOCKET NUMBER 68 69 EVENT DATE 74 7S REPORT DATE BO EVENT DESCRIPTION AND PROBABLE CONSEQUENCES@

((TI] I During the refueling core shuffle, 6 of the existing 53

[]JI] 11..._...:c::.o=n:..:t::r:.;o=l:.....::r:..:o=d:.::s::.._.;w:.:.e=r:.::e::.......f=.o:::::..l::u~n~d~.i.t:..::.o~h~a...:.v:...lie_...,b._r.....o....k.,.e n..__.s...,pl!'-"-i....a...e...r.__....f....;i...n.i.g~e:..i.r_.s:l-.c;ia..1.f..:-~---1

[TITI 1.. I_...;f:..e=c:..::t:..:1::.;'n=gi.....:B::.-::::C:.::O:.!n=..:t:::;r=o:.:l=--:r:..o:::::.::d~s~*.__-./i.A..._p~r..liie..1.. ,1.,.*m .......i,.n.ua....r""-""y~e.._y,.__.,.a.,.J_.1.,,rn.._t.._.i..a....n.i.-....auf_t~h.ce;___ __,

c:mJ LI--'a..._f..1.f..i;e;.ic...t._.e.d...__rl...l..JaLl..dulue=-i..t..::s......ir.:e'"'-liia....c...t_1....* v.¥.-1.i..1.t...;y~w.iw..a.ur_+~h......;:s:...h...,a.......,wu;:e::.i.a...._...t ...h.,,a:)..t..._.....t,.h..,e_...s...,h.....u...t.i....ldd...,ouw:i.Jn..._--'

[Il[) LI-~m:.:;a=r..::g...1=-'no..:..&.*--:t ' ....h.. ., .o...u>.:;g;l.olh.-....r .....e...d,..u.....,.c...e""'d""',,__....

w.._a...s...._...su.n...f_f........i ...c....i....e-.n........t__.t_.a..._...m.,.e...e-.t..__....T...e,..c.....,.h....p...1..,'c.......

a ...1_ ___.

([IT] ._I_ _ S.. tp._e.;;..;;.c. ;;;i;.;;f;.;;1;;;..c;;..;;:a..::t;.;:i:..;o:..;n~.;;;l..::i;;;;m;;.;:i::..t;:;;.s=-:.._...:T::..:h=i.::s~i:..:s~-=t'°"'h:o.::e=--f=-1='

' =r~sut,,__,o...c..._...c"""u...r...r.e~n...,c...,,e..__.o ......f~t...h...,1._*s......_.

[]I[] type.

7 8 9 BO SYSTEM CAUSE CAUSE COMP. VALVE CODE CODE SUBCODE COMPONENT CODE SUBCODE SUBCODE ITIIJ !RIB I@ w@ w@ lclolN IR lo I ol@ LIJ@) LzJ@

1 8 II 10 11 12 13 18 19 20 SEQUENTIAL OCCURRE;NCE REPORT REVISION

~ LER'RO LVENTYEAR REPORT NO. CODE TYPE NO.

~ REPORT NUMBER 17 I 91 I I I a 14 11 I 1.....-1 lo I 31 lk_J I I LQJ 21 22 23 24 26 27 28 29 30 31 32 ACTION FUTURE EFFECT SHUTDOWN ~ ATI"ACHMENT NPRD-4 PRIME COMP. COMPONENT TAKEN ACTION ON PLANT METHOD HOURS 22 SUBMITI"ED FORM sue. SUPPLIER MANUFACTURER l£-J@~@ .. l..£J@ Ll!@ IO IO 19 I I LX.J@ Lil@ l.l:I.J@ lw 11 I 21 ol@

33 34 35 36 37 40 41 42 43 .... 47 CAUSE DESCRIPTION AND CORFIEC"rlVE ACTIONS @

o:::I]J I The cause of this occurrence is under investigation. Based I.

IJ:II] I on preliminary reports, 25 control rods haye been replaced III2J L-F_u_r_t_h_e_r__c_o_r_r_e_c_t_i_v_e...:;1_1_*f__r_e....q._u.;..i.;..r_e.;..d...;__w_i_l_l"-b"'-""'e__s"""u;;.;;b;..;;m.-i_*t~t_e_d~w""'1;;.*t=h.......,,t::.:.h~e,,___.

[!))]I cause of the occurrence in a supplemental report.

OE 7 B 9 so FACILITY ljQ\ METHOOOF STATUS  % l'OWER OTHER STATUS \Cl DISCOVERY DISCOVERY DESCRIPTION @

o::lII lJiJ@) fO I Of O!@I N/A L!.J@I Control Rod Changeout Inspection 7 8 9 10 12 13 .... 45 46 80 C\

ACTIVITY RELEASEO OF RELEASE CONTENT AMOUNT OF ACTIVITY LOCATION OF RELEASE IIlII W@ Li(§I 1 8 9 10 11 NIA I NIA I ao

'ERSONNEL EXPOSURES Q..

NUMBER ~TYPE~ DESCRIPTION ETIJJOfO 10 l~LJ~.__~~~~~N..__A"-~~~~~~~~~~~~~~~~---'

7 B 11 11 12 13 BO

'ERSONNEL INJURIES ~

NU!ir!BER DESCRll'T10N6 ETIJ B IO!u 10 l@>~~~~~~--'N~A~~~~~~~~~~~~~~~~~

9 11 12 BO LOSS OF OR DAMAGE TO FACILITY '4J'I TYPE DESCRIPTION ~

~

7 8 9 Lz.J@).__~~~~~~~~...,.,...

10

......~~~~~~~~~~~~~~~~--80

'UBLICITY C\ NRC USE O ISSUEDt.::;\ DESCRIPTION~ NL y 1IIIJ l.Y.J~.__~~~~~~~~----~..__~~~~~~~~~--' I I I I I I I I I I I I 80I 7 8 9 10 68 69 NAMEOFPREPARER----_A_.__ w_.__K_a~p~p=--l_e______~ PHoNa609) 365-7000 Salem Ext 628

.... 9 07 0 9 0 J. 77-

{l

--~------- - ----

- -- --*"'-. *--~----***""--..---~---

. ___ ........, __~..,.._._~*------*-*-*-** *- *--********* *---* - ....... __ .....~ ...-*---***-**

Repm: t Number:

e 79-47/03L Report Date~. 6/30/79 Occurrence Dat~~ 5/31/79 Facility: Salem Generating Station Public Service Electric & Gas Company Hancocks Bridge, New Jersey 08038 IDENTIFICATION OF OCCURRENCE:

Failed Spider *"Fingers '°On" Six ( 6) ContJ:ol Rods CONDITIONS PRIOR TO OCCURRENCE:

Operational Mode 6, Refueling DESCRIPTION OF OCCURRENCE:

During the refueling core shuffle, six (6) of the existing fifty-three (53) control rods were found to have broken spider fingers affecting eight{8) control rodlets.

DESIGNATION OF APPARENT CAUSE OF OCCURRENCE:

The cause of the broken spiders is under investigation and will be sub-mitted in a supplemental report.

ANALYSIS OF OCCURRENCE:

The Station Reactor Engineer conducted a preliminary evaluation of reacti-vity worth of the affected rodlets which showed that the shutdown margin, though reduced, was sufficient to meet Technical Specification limits.

Further safety analysis of this occurrence will be included in a supple-mental report.

CORRECTIVE ACTION:

Based on preliminary investigation, twenty-five (25) control rods have been replaced. Further corrective action required as a result of the on-going investigation will be submitt~d in a supplemental report.

FAILURE DATA:

Rod Cluster Control Assembly Manufacturer: Westinghouse Prepared by~~A_.~W-=-*-=-K~aAp~p~l~e~~~~~

Manager - Salem Generating Station SORC Meeting No. ~~~~~~~~~~

51-79


*--*-------