EOP:

FR-S.1 TITLE:

RESPONSE

TO REACTOR RESTART/ATWS REV:

4 PAGE 1 of 10 ROCHESTER GAS AND ELECTRIC CORPORATION GINNA STATION CONTROLLED COPY NUMBER TECHNICAL REVIEW PORC REVIEW DATE P

NT SUPERIN EN NT EFFE TIVE DATE GINNASTATION "IAP)

QA NON-QA REVIEWED BY:

PDR ADOC[C 05000244 P

CATEGORY 1.0 DATE TIME COMPLE I ED:

DATE TIME:

0

EOP:

FR-S.1

RESPONSE

TO REACTOR RESTART/ATWS REV:

4 PAGE 2 of 10 A.

PURPOSE This procedure provides actions to add negative reactivity to a core which is observed to be critical when expected to be shut'own.

B.

ENTRY CONDITIONS/SYMPTOMS l.

ENTRY CONDITIONS This procedure is entered from:

a.

E-O, REACTOR TRIP OR SAFETY INJECTION, when reactor trip is not verified and manual trip is not effective.

b.

F-0.1, SUBCRITICALITY Critical Safety Function Status Tree on either a

RED or ORANGE condition.

IP

EOP:

FR-S.1

RESPONSE

TO REACTOR RESTART/ATWS REV:

4 PAGE 3 of 10 STEP ACTION/EXPECTED RESPONSE

RESPONSE

NOT OBTAINED NOTE:

o Steps 1 through 4 are IMMEDIATE ACTION steps.

o Adverse CNMT values should be used whenever CNMT pressure is greater than 4 psig or CNMT radiation is greater than 10

~ R/hr.

O 1

Verify Reactor Trip:

o At least one train of reactor trip breakers OPEN o

Neutron flux - DECREASING o

MRPI indicates

- ALL CONTROL RODS ON BOTTOM Manually trip reactor.

IF reactor trip breakers NOT open, THEN manually insert control rods.

O 2

Verify Turbine Stop Valves CLOSED Manually trip turbine.

IF turbine trip can NOT be

verified, THEN close both MSIVs.

O 3

Check AFW Pumps Running:

a.

MDAFW pumps - RUNNING b.

TDAFV pump - RUNNING IF NECESSARY

a. Manually start MDAFV pumps.
b. Manually open steam supply valves.

~ MOV-3505A

~ MOV-3504A

EOP:

FR-S.1 TITLE:

RESPONSE

TO REACTOR RESTART/ATWS REV:

4 PAGE 4 of 10 STEP ACTION/EXPECTED RESPONSE

RESPONSE

NOT OBTAINED NOTE: If offsite power is lost coincident with SI, then MCC C and MCC D lockout relays must be reset to restore BA and RMW pumps.

O 4

Initiate Emergency Boration Of RCS:

a.

Check RCS pressure

- GREATER THAN 1400 psig [1200 psig adverse CNMT]

b. Verify at least one charging pump - RUNNING
c. Align boration path:
1) Start two BA transfer pumps
2) Open MOV-350
3) Verify BA flow
d. Verify charging flow path:

o Charging valve to loop B cold leg (AOV-294) - OPEN A

o Charging flow control valve (HCV-142) - DEMAND AT 0%

e.

Check PRZR PORV status o

RCS pressure

- LESS THAN 2335 PSIG o

PORVs - CLOSED

a. IF SI flow indicated, THEN go to Step 5.

IF NOT, THEN go to Step 4b.

b. Perform the following:
1) Reset SI if necessary.
2) Start one charging pump.
c. IF flow can NOT be established, THEN refer to AP-CVCS.2, IMMEDIATE BORATION.
d. Manually align valves.

IF IA to CNMT isolated, THEN verify alternate charging valve, (AOV-392A), relieving to RCS.

e. Verify CNMT ventilation isolation.

IF dampers NOT

closed, THEN momentarily deenergize CNMT particulate monitor, R-ll, to actuate CVI.

o Annunciator F-19, PRZR PORV OUTLET HI TEMP - EXTINGUISHED

0 0

EOP:

FR-S. 1 TITLE:

RESPONSE

TO REACTOR RESTART/ATWS REV:

4 PAGE 5 of 10 STEP ACTION/EXPECTED RESPONSE

RESPONSE

NOT OBTAINED 5

Check If The Following Trips Have Occurred:

a. Reactor trip
a. Dispatch AO to locally trip reactor:

o Trip MG set breakers at bus 13 and bus 15.

b. Turbine trip o

Open reactor trip breakers locally.

b. Dispatch operator to locally trip turbine using manual trip lever on west end of HP turbine.

6 Check S/G Level:

a. Narrow range level in at least one S/G - GREATER THAN 5X [25X adverse CNMT]
a. Perform the following:
1) Verify total feed flow greater than 400 gpm.

IF NOT, THEN manually start pumps and align valves as necessary.

2) Maintain total feed flow greater than 400 gpm until narrow range level greater than 5X [25X adverse CNMT] in at least one S/G.
b. Control feed flow to maintain narrow range level between 17X

[25X adverse CNMT] and 50X

EOP:

FR-S.1

RESPONSE

TO REACTOR RESTART/ATWS REV 4

PAGE 6 of 10 STEP ACTION/EXPECTED RESPONSE

RESPONSE

NOT OBTAINED 7 Verify Dilution Paths ISOLATED Manually isolate dilution paths.

o Place RMW mode switch to BORATE o

Verify RMV to blender (HCV-111)

- CLOSED o

Verify RMV pumps OPP 8

Check For Reactivity Insertion From Uncontrolled RCS Cooldown:

Stop any controlled cooldown and go to Step 14.

o Core exit T/Cs - DECREASING IN AN UNCONTROLLED MANNER

-OR-o Any S/G pressure

- DECREASING IN AN UNCONTROLLED MANNER 9

Check MSIVs CLOSED Manually close valves.

10 Verify MFW Isolation:

a.

MPV pumps - TRIPPED b.

MFW flow control valves - CLOSED

~ MFV regulating valves

~

MPW bypass valves

a. Manually close MFV pump discharge valves and trip MFW pumps.
b. Place A and B S/G MPV regulating valve and bypass valve controllers to MANUAL at OX demand.

EOP:

FR-S.1 TITLE:

P

RESPONSE

TO REACTOR RESTART/ATWS REV 4

PAGE 7 of 10 STEP ACTION/EXPECTED RESPONSE

RESPONSE

NOT OBTAINED ll Identify Faulted S/G:

o ANY S/G PRESSURE DECREASING IN AN UNCONTROLLED MANNER Go to Step 14.

-OR-o ANY S/G COMPLETELY DEPRESSURIZED

I 0

EOP:

FR-S.1 TITLE:

RESPONSE

TO REACTOR RESTART/ATWS REV 4

PAGE 8 of 10 STEP ACTION/EXPECTED RESPONSE

RESPONSE

NOT OBTAINED CAUTION o

AT LEAST ONE S/G MUST BE MAINTAINEDAVAILABLEFOR RCS COOLDOWN.

o IF BOTH S/GS ARE FAULTED, AT LEAST 50 GPM PEED FLOW SHOULD BE MAINTAINED TO EACH S/G.

12 Isolate Feed Flow To Faulted S/G:

o Close faulted S/G MDAFW pump discharge valve

~ S/G A, MOV-4007

~ S/G B, MOV-4008 o

Pull stop faulted S/G MDAFW pump o

Close faulted S/G TDAPW flow control valve

~ S/G A, AOV-4297

~ S/G B, AOV-4298 o

Verify faulted S/G MFW regulating valve and bypass valve - CLOSED Manually close valves.

IP valves can NOT be closed, THEN dispatch AO to locally isolate flowpaths as necessary.

~ S/G A, HCV-466 and HCV-480

~ S/G B, HCV-476 and HCV-481 o

Verify MFW pump discharge valves CLOSED

~ S/G A, MOV-3977

~ S/G B, MOV-3976 o

Verify MDAFW pump crosstie valves - CLOSED

~ MOV-4000A

~ MOV-4000B

EOP:

FR-S.1 TITLE:

RESPONSE

TO REACTOR RESTART/ATWS REV' PAGE 9 of 10 STEP ACTION/EXPECTED RESPONSE

RESPONSE

NOT OBTAINED 13 Isolate Steam Flow From Faulted S/G:

o Verify faulted S/G ARV - CLOSED

~ S/G A, AOV-3411

~.S/G B, AOV-3410 o

Close faulted S/G TDAFV pump steam supply valve and place in PULL STOP Manually close valves.

IP valves can NOT be closed, THEN dispatch AO to locally isolate flowpaths as necessary.

~ S/G A, MOV-3505A

~ S/G B, MOV-3504A o

Verify faulted S/G blowdown and sample valves

- CLOSED

~ S/G A, AOV-5738 and AOV-5735

~ S/G B, AOV-5737 and AOV-5736 o

Dispatch AO to complete faulted S/G isolation (Refer to Attachment FAULTED S/G) 14 Verify Reactor Subcritical:

o Power range channels

- LESS THAN 5'

Intermediate range channels startup rate - NEGATIVE Perform the following:

a. Continue to borate.
b. IF boration NOT available, THEN allow RCS to heat up.

Perform actions of other FR procedures in effect which do NOT cooldown or otherwise add positive reactivity to the core.

c.-Return to Step 4.

EOP:

FR-S.1

RESPONSE

TO REACTOR RESTART/ATWS REV:

4 PAGE 10 of 10 STEP ACTION/EXPECTED RESPONSE

RESPONSE

NOT OBTAINED CAUTION BORATION SHOULD CONTINUE TO OBTAIN ADEQUATE SHUTDOWN MARGIN DURING SUBSEQUENT ACTIONS.

15 Return to Procedure And Step In Effect

-END-

EOP:

FR-S.1

RESPONSE

TO REACTOR RESTART/ATWS REV 4

PAGE 1 of 1 FR-S.1 APPENDIX LIST TITLE 1)

ATTACHMENT FAULTED S/G PAGES