Rev 2 to FR-H.5, Response to Steam Generator Low Level
ML17250B129
Person / Time
Site: Ginna Constellation icon.png
Issue date: 04/09/1990
From: Widay J
ROCHESTER GAS & ELECTRIC CORP.
To:
Shared Package
ML17250B096 List:
References
FR-H.5, NUDOCS 9004200750
Download: ML17250B129 (5)


Text

EOP:

FR-H.5 TITLE

RESPONSE

TO STEAM GENERATOR LOW LEVEL REV 2

PAGE 1 of 5 ROCHESTER, GAS AND ELECTRIC CORPORATION GINNA STATION CONTROLLED COPY NUMBER TECHNICAL REVIEW PORC REVIEW DATE SUPERINTEN E

EFFECTIVE DATE QA M NON-QA CATEGORY 1.0 REVIEWED BY:

Gi t DNA STATlON START:

DATE TlViE 004200750 900410 lU PDR ADOCK 05000244J

'- 'P PNU)i

( 'lME'

EOP:

FR-H.5

RESPONSE

TO STEAM GENERATOR LOW LEVEL REV 2

PAGE 2 of 5 A.

PURPOSE This procedure provides actions to respond to a S/G low level condition.

B.

ENTRY CONDITIONS/SYMPTOMS 1.

ENTRY CONDITIONS This procedure is entered from:

a.

F-0.3, HEAT SINK Critical Safety Function Status

Tree, on a YELLOW condition.

EOP:

FR-H.5 TITLE:

RESPONSE

TO STEAM GENERATOR LOW LEVEL REV 2

PAGE 3 of 5 STEP ACTION/EXPECTED RESPONSE

RESPONSE

NOT OBTAINED CAUTION STEAM RELEASES FROM AFFECTED S/G(S)

SHOULD BE MINIMIZED.

NOTE:

o Throughout this procedure "affected" refers to any S/G in which narrow range level is less than 5X [25X adverse CNMT].

o Adverse CNMT values should be used whenever CNMT pressure is greater than 4 psig or CNMT radiation is greater than 10

~ R/hr.

1 Identify Affected S/G(s):

a.

Narrow range level - LESS THAN 5X [25X adverse CNMT]

a. Return to procedure and step in effect.

2 Verify S/G Blowdown Isolation Valves From Affected S/G(s)

CLOSED

~ AOV-5738 for S/G A

~ AOV-5737 for S/G B

Place S/G blowdown valves master switch to CLOSE.

IF valves can NOT be closed

manually, THEN dispatch AO to locally isolate blowdown.

o S/G A, close V-5701 o

S/G B, close V-5702

EOP:

FR-H.5 TITLE:

RESPONSE

TO STEAM GENERATOR LOW LEVEL REV 2

PAGE 4 of 5

STEP ACTION/EXPECTED RESPONSE

RESPONSE

NOT OBTAINED CAUTION AFV FLOV SHOULD NOT ESTABLISHED TO ANY FAULTED S/G THAT HAS BEEN ISOLATED UNLESS NEEDED POR RCS COOLDOVN.

3 Check If Affected S/G(s)

Secondary Side Is Intact:

o Pressure in affected S/G(s)-

STABLE OR INCREASING o

Pressure in affected S/G(s)-

GREATER THAN 100 PSIG IP affected S/G(s) previously identified as faulted, THEN return to procedure and step in effect.

IP affected S/G pressure decreasing in an uncontrolled manner or completely depressurized and has not been previously isolated, THEN go to E-2, FAULTED STEAM GENERATOR ISOLATION, Step 1.

4 Check AFW Flow To Affected S/G(s)

GREATER THAN 50 GPM IF affected S/G(s) wide range level greater than 35 inches

[110 inches adverse CNMT], THEN establish AFV flow as necessary to refill affected S/G(s).

IF affected S/G(s) wide range level less than 35 inches

[110 inches adverse CNMT], THEN establish APV flow to affected S/G(s) at a rate not to exceed 100 gpm.

5 Continue Filling Affected S/G(s) Until Narrow Range Level Greater Than 54

[254 adverse CNMT]

EOP:

FR-H.5

RESPONSE

TO STEAM GENERATOR LOW LEVEL REV 2

PAGE 5 of 5 STEP ACTION/EXPECTED RESPONSE

RESPONSE

NOT OBTAINED 6

Return To Procedure And Step In Effect

-END-