ML17250B137

From kanterella
Jump to navigation Jump to search
Rev 2 to FR-P.2, Response to Anticipated PTS Condition
ML17250B137
Person / Time
Site: Ginna Constellation icon.png
Issue date: 04/09/1990
From: Widay J
ROCHESTER GAS & ELECTRIC CORP.
To:
Shared Package
ML17250B096 List:
References
FR-P.2, NUDOCS 9004200761
Download: ML17250B137 (12)


Text

EOP:

FR-P.2 TITLE:

RESPONSE

TO ANTICIPATED PRESSURIZED THERMAL SHOCK CONDITION REV:

2 PAGE 1 Of 5 ROCHESTER GAS AND ELECTRIC CORPORATION GINNA STATION CONTROLLED COPY NUMBER TECHNICAL REVIEW PORC REVIEW DATE P

NT SUPERINT ND NT o

EFFECTI E

DATE QA+

NON-QA REVIEWED BY:

SOO4aOO7sj.

9Oo4io PDR ADDCR 00000244 I,

p PNU CATEGORY 1.0 Gli~liMASTATION S~AR r:

DATE TlViL C'3b/I PL"TFD:

DATE TIME:

t w,L

EOP:

FR-P.2 TITLE:

RESPONSE

TO ANTICIPATED PRESSURIZED THERMAL SHOCK CONDITION

.REV:

2 PAGE 3 of 5 STEP ACTION/EXPECTED RESPONSE

RESPONSE

NOT OBTAINED II NOTE:

o A faulted S/G is any S/G that is depressurizing in an uncontrolled manner or is completely depressurized.

o Adverse CNMT values should be used whenever CNMT pressure is greater than 4 psig or CNMT radiation is greater than 10

~ R/hr.

1 Check RCS Cold Leg Temperatures STABLE OR INCREASING Try to stop RCS cooldown:

a. Ensure S/G ARVs closed.
b. Close both S/G MSIVs.
c. Ensure MFW flow control valves closed.

~ MFW regulating valves

~

MFW bypass valves

d. Ensure MFW pumps tripped.
e. IF S/G pressure less than condensate
pressure, THEN stop all condensate pumps.
f. IF RHR system in service, THEN stop any cooldown from RHR system.
g. Control total feed flow to non-faulted S/G(s) greater than 200 gpm until narrow range level greater than 5X [25X adverse CNMT] in at least one non-faulted S/G.

WHEN S/G level greater than 5X [25X adverse CNMT] in one non-faulted S/G, THEN limit feed flow to stop RCS cooldown.

This Step continued on the next page.

W

EOP:,

FR-P.2 TITLE:

RESPONSE

TO ANTICIPATED PRESSURIZED THERMAL SHOCK CONDITION REV 2

PAGE 5 of 5 STEP ACTION/EXPECTED RESPONSE

RESPONSE

NOT OBTAINED 4

Determine If Additional RCS Cooldown Restrictions Are Required:

a.

Cooldown rate in RCS cold legs-GREATER THAN 100'F IN ANY 60 MINUTES PERIOD b.

RCS cooldown is permitted with the following restrictions:

1) Maintain RCS pressure and cold leg temperatures within the limits of Figure C/D LIMITS
a. Additional restrictions are not required.

Go to Step 5.

2) Maintain cooldown rate in RCS cold legs less than 100'F in any 60 minutes period 5

Return To Procedure And Step In Effect

-END-

1

EOP:

FR-P.2 TITLE:

RESPONSE

TO ANTICIPATED PRESSURIZED THERMAL SHOCK CONDITION REV:

2 PAGE 1 of 1

FR-P.2 APPENDIX LIST TITLE PAGES 1)

FIGURE TECH SPEC C/D 2)

FIGURE C/D LIMITS 3)

ATTACHMENT N2 PORVS

4

EOP2 TITLE:

FR-P.2

RESPONSE

TO ANTICIPATED PRESSURIZED THERMAL SHOCK CONDITION REV 2

PAGE 1 of 1

FIGURE TECH SPEC C

D RCS 2500 2400 2300 2200 2100 2000 1900 1800 1700 1600 1500 1400 1300 1200 1100 1000 900 800 700 600 500 400 300 200 100 0

PRESSURE (PSIG)

RCS PRESSURE INCREMENTS 20 PSIG 60'F/HR 100'F/HR ACCEPTABLE REGION FOR RCS REPRESSURIZATION TEMPERATURE INCREMENTS 10'F 0

50 100 150 200 250 300 350 400 450 500 RCS COLD LEG TEMPERATURE ('F)

EOP:

FR-P.2 TITLE:

RESPONSE

TO ANTICIPATED PRESSURIZED THERMAL SHOCK CONDITION REV 2

PAGE 1 of 1 RCS 2500 2400 2300 2200 2100 2000 1900 1800 1700 1600 1500 1400 1300 1200 1100 1000 900 800 700 600 500 400 300 200 100 0

PRESSURE (PSIG)

RCS PRESSURE INCREMENTS 20 PSIG FIGURE C

D LIMITS ACCEPTABLE REGION FOR COOLDOVN TEMPERATURE INCREMENTS 10'F 200 250 300 350 400 450 500 550 600 650 700 RCS COLD LEG TEMPERATURE ('F)

it