EOP:

FR-H.2 T17t.E:

RESPONSE

TO STEAM GENERATOR OVERPRESSURE REV:

2 PAGE.1 of 6 ROCHESTER GAS AND ELECTRIC CORPORATION GINNA STATION CONTROLLED COPY NUMBER TECHNICAL REVIEW PORC REVIEW DATE SUPERINT D NT EFFECTIVE DATE QA~ NON-QA CATEGORY 1.0 REVIEWED BY:

GiNNA PjTATION 8! P,RT:

DATF T!i~'

9004200743 9004jp +i

, PDR ADOCg PgPPPP44~

PNU II 1 liUIE.

FR-H.2

RESPONSE

TO STEAM GENERATOR OVERPRESSURE REV 2

PAGE 2 of 6 A.

PURPOSE This procedure provides actions for an overpressure condition affecting any S/G where pressure has increased above the highest steamline safety valve setpoint.

B.

ENTRY CONDITIONS/SYMPTOMS 1.

ENTRY CONDITIONS This procedure is entered from:

a.

F-0.3, HEAT SINK Critical Safety Function Status

Tree, on a YELLOW condition.

EOP:

FR-H.2 TITLE:

RESPONSE

TO STEAM GENERATOR OVERPRESSURE REV 2

PAGE 3 of 6 STEP ACTION/EXPECTED RESPONSE

RESPONSE

NOT OBTAINED NOTE:

o Throughout this procedure, "affected" refers to any S/G in which pressure is greater than 1140 psig.

o Adverse CNMT values should be used whenever CNMT pressure is greater than 4 psig or CNMT radiation is greater than 10

~ R/hr.

1 Identify Affected S/G(s):

a.

Any S/G pressure

- GREATER THAN 1140 PSIG

a. Return to procedure and step in effect.

2 Verify FW Isolation To Affected S/G(s):

a.

MFV pumps

- TRIPPED b.

MFV flow control valve(s)-

CLOSED

a. Trip MFV pumps.
b. Manually close valves.

~

MFW regulating valve(s)

~

MFW bypass valve(s) c.

MFW pump discharge valve(s)

CLOSED

c. Manually close valves.

3 Check Affected S/G(s)

Narrow Range Level LESS THAN 90%

I'85% adverse CNMT]

Go to FR-H.3,

RESPONSE

TO STEAM GENERATOR HIGH LEVEL, Step l.

EOP:

FR-H.2 TITLE:

RESPONSE

TO STEAM GENERATOR OVERPRESSURE REV 2

PAGE 4 of 6 STEP ACTION/EXPECTED RESPONSE

RESPONSE

NOT OBTAINED CAUTION IF AFFECTED S/G NARROW RANGE LEVEL INCREASES TO GREATER THAN 90X [85X ADVERSE CNMT], THEN STEAM SHOULD NOT BE RELEASED PROM THE AFFECTED S/G(S).

4 Try To Dump Steam From The Affected S/G(s):

o Open S/G ARVs

-OR-Go to Step 6.

o Open MSIV bypass valves

-OR-o Open steam supply valves to TDAFW pump 5

Check Affected S/G(s)

Pressure:

a. Pressure

- DECREASING

b. Pressure

- LESS THAN 1140 PSIG

c. Control steam release to maintain S/G pressure less than 1140 psig
d. Return to procedure and step in effect a.

Go to Step 6.

b. Return to Step 3.

EOP:

FR-H.2

. TITLE

RESPONSE

TO STEAM GENERATOR OVERPRESSURE REV 2

PAGE 5 of 6

STEP ACTION/EXPECTED RESPONSE

RESPONSE

NOT OBTAINED CAUTION APW FLOW SHOULD REMAIN ISOLATED TO AFFECTED S/G(S)

UNTIL A STEAM RELEASE PATH IS ESTABLISHED.

6 Close AFW And SAFW Flow Control Valves To Affected S/G (s) o S/G A Stop pumps feeding affected S/G(s).

~ MOV-4007 and AOV-4480, MDAFW pump

~ AOV-4297, TDAFW pump

~ MOV-9701A, SAFW pump o

S/G B

~ MOV-4008 and AOV-4481, MDAPW pump

~ AOV-4298, TDAFW pump

~ MOV-9701B, SAFW pump 7

Check RCS Hot Leg Temperatures LESS THAN 535'F Cool down RCS to less than 535'P by dumping steam from the unaffected S/G.

EOP:

FR-H.2 TITLE:

RESPONSE

TO STEAM GENERATOR OVERPRESSURE REV:

2 PAGE 6 of 6 STEP ACTION/EXPECTED RESPONSE

RESPONSE

NOT OBTAINED 8

Continue Attempts To Manually Or Locally Dump Steam From Affected S/G(s):

o Open S/G ARVs

-OR-o Open steam supply valves to TDAPW pump

-OR-o Dispatch AO to perform the following:

a.

Open affected S/G MSIV bypass valve Open both priming air ejector steam isolation valves

~ V-3580

~ V-3581 9

Return To Procedure And Step In Effect

-END-