ML17250B139

From kanterella
Jump to navigation Jump to search
Rev 2 to FR-S.2, Response to Loss of Core Shutdown
ML17250B139
Person / Time
Site: Ginna Constellation icon.png
Issue date: 04/09/1990
From: Widay J
ROCHESTER GAS & ELECTRIC CORP.
To:
Shared Package
ML17250B096 List:
References
FR-S.2, NUDOCS 9004200763
Download: ML17250B139 (8)


Text

EOP:

FR-S.2 TITLE:

RESPONSE

TO LOSS OF CORE SHUTDOWN REV:

2 PAGE 1 of 4 ROCHESTER GAS AND ELECTRIC CORPORATION GINNA STATION CONTROLLED COPY NUMBER TECHNICAL REVIEW PORC REVIEW DATE P

T SUPERIN EN ENT

'7 10 EFFE TIVE DATE QA~

NON-QA CATEGORY 1.0 GiNNASTATlON i'T DATE 1 I'A-REVIEWED BY:

V004200763 9004ip PDR ADOCg 0500024y P

PNU DATQ TJMF.:

EOP:

FR-S.2

RESPONSE

TO LOSS OF CORE SHUTDOWN REV 2

PAGE 2 of 4 A.

PURPOSE This procedure provides actions to restore the core to an adequate shutdown condition.

B.

ENTRY CONDITIONS/SYMPTOMS 1.

ENTRY CONDITIONS This procedure is entered from:

a.

F-0.1, SUBCRITICALITY Critical Safety Function Status

Tree, on either YELLOW condition.

EOP:

FR-S.2 TITLE:

RESPONSE

TO LOSS OF CORE SHUTDOWN REV 2

PAGE 3 of 4 STEP ACTION/EXPECTED RESPONSE

RESPONSE

NOT OBTAINED NOTE:

o Adverse CNMT conditions or loss of forced air cooling may result in failure of NIS detectors.

o Adverse CNMT values should be used whenever CNMT pressure is greater than 4 psig or CNMT radiation is greater than 10-

~ R/hr.

1 Check Intermediate Range Flux:

a. Flux - EITHER CHANNEL LESS THAN 1O xo AMPS
a. Perform the following:
1) IF neither intermediate range channel is decreasing THEN initiate boration.
b. Check the following:

o Both intermediate range channels

- LESS THAN 1O-xo AMPS

2) Continue with Step 2.

WHEN flux is LESS THAN 10-'~ amps on any operable

channel, THEN do Steps 1b, c and d.
b. Continue with step 2.

WHEN either condition met, THEN do Steps 1c and d.

-OR-o Greater than 20 minutes since reactor trip

c. Verify source range detectors-ENERGIZED
d. Transfer Rk-45 recorder to one source range and one intermediate range channel
c. Manually energize source range detectors by depressing P-6 permissive defeat pushbuttons (2

of 2).

IP source ranges can NOT be

restored, THEN refer to ER-NIS.1, SR MALFUNCTION, and go to Step 2.

EOP:

FR-S.2 TITLE:

RESPONSE

TO LOSS OF CORE SHUTDOWN REV:

2 PAGE 4 of 4 STEP ACTION/EXPECTED RESPONSE

RESPONSE

NOT OBTAINED 2

Check Source Range Channels ZERO OR NEGATIVE STARTUP RATE Borate until source range startup rate is negative or zero (Refer to AP-CVCS.2, IMMEDIATE BORATION).

CAUTION BORATION SHOULD CONTINUE TO OBTAIN ADEQUATE SHUTDOWN MARGIN DURING SUBSEQUENT ACTIONS.

3 Return To Procedure And Step In Effect.

-END-

fg