RBS USAR 1 of 1 August 1987 TABLE 14.2-1 THERMAL EXPANSION EVALUATION CRITERIA Transducer Level 2 Tolerance (in)
Level 1 Tolerance (in)
Transducer Level 2 Tolerance (in)
Level 1 Tolerance (in)
Location SA2-MX
-2.035/-1.679
-2.561/-1.153 SD2-MX
-2.035/-1.679
-2.391/-1.323 Along axis of main steam pipe near MSIVs SA6-MX
-2.100/-1.843
-2.525/-1.417 SD6-MX
-2.089/-1.832
-2.264/-1.657 Perpendicular to SRV discharge pipe SA6-MY 0.665/0.279 0.786/0.159 SD6-MY 0.666/0.281 0.957/-0.010 Vertical SA6-MZ 1.030/0.799 1.488/0.341 SD6-MZ
-1.041/-0.810
-1.479/-0.372 Aligned along axis of SRV discharge SA7-MY 2.142/1.954 2.312/1.784 NA NA NA Vertical near shield wall SA8-MY 1.145/0.888 3.310/-1.277 NA NA NA Vertical RCIC line SA9-MX
-1.906/-1.613
-3.683/0.164 NA NA NA Normal to shield wall RCIC line SB2-MX
-2.046/-1.646
-3.440/-0.252 SC2-MX
-2.046/-1.646
-3.440/-0.252 Along axis of main steam pipe near MSIVs SB6-MX
-2.301/-2.085
-3.077/-1.310 SC6-MX
-2.301/-2.085
-3.077/-1.310 Perpendicular to SRV discharge pipe SB6-MY 1.058/0.673 1.679/0.052 SC6-MY 1.058/0.673 1.679/0.052 Vertical SB6-MZ
-1.722/-1.423
-2.866/-0.279 SC6-MZ 1.722/1.423 2.866/0.279 Aligned along axis of SRV discharge RA1-MY 0.417/0.230 0.703/-0.056 RB1-MY 0.417/0.230 0.703/-0.056 Recirc. vertical RA2-MZ 0.877/0.630 1.954/-0.446 RB2-MZ
-0.877/-0.630
-1.954/+0.446 Recirc. normal to shield wall RA3-MX 0.509/0.322 3.262/-2.431 RB3-MX
-0.509/-0.322
-3.262/2.431 Discharge valve RA3-MZ 0.556/0.309 3.171/-2.306 RB3-MZ
-0.556/-0.309
-3.171/2.306 Discharge valve RA5-MX
-0.306/-0.556 4.000/-4.000 RB5-MX 0.306/0.556
-4.000/4.000 Pump discharge RA5-MY
-1.454/-1.850 4.000/-4.000 RB5-MY
-1.454/-1.850 4.000/-4.000 Vertical pump RA5-MZ 0.008/-0.314 1.267/-1.573 RB5-MZ
-0.008/0.314
-1.267/1.573 Pump discharge RA6-MZ
-1.006/-0.818
-1.761/-0.063 RB6-MZ 1.006/0.818 1.761/0.063 Tangent to shield wall(suction)
RBS USAR NOTE: Actual transducer locations to be determined at site prior to fuel loading.
1 of 1 August 1987 TABLE 14.2-2 TEMPERATURE TRANSDUCERS Transducer Test Temperature A
B C
D Range (°F)
SA1-T SB1-T SC1-T SD1-T 50-550 SA5-T SB5-T SC5-T SD5-T 50-550 SA10-T 50-550 RA4-T RB4-T 50-550 RB7-T 50-550
1 of 1 August 1987 RBS USAR TABLE 14.2-3 PIPING VIBRATION OPERATING TRANSIENTS Transducer Displacement Level 2 Tolerance Displacement Level 1 Tolerance Transducer Displacement Level 2 Tolerance Displacement Level 1 Tolerance Location SA3-S 101 x 10
-6in/in 903 x 10
-6in/in SA4-S 101 x 10
-6in/in 903 x 10
-6in/in Loop A SRV sweepolet SA11-S 25 x 10
-6in/in 1122 x 10
-6in/in SA12-S 25 x 10
-6in/in 1122 x 10
-6in/in Loop A main steam pipe SB3-S 101 x 10
-6in/in 935 x 10
-6in/in SB4-S 101 x 10
-6in/in 935 x 10
-6in/in Loop B SRV sweepolet SC3-S 101 x 10
-6in/in 935 x 10
-6in/in SC4-S 101 x 10
-6in/in 935 x 10
-6in/in Loop C SRV sweepolet SD3-S 104 x 10
-6in/in 933 x 10
-6in/in SD4-S 104 x 10
-6in/in 933 x 10
-6in/in Loop D SRV sweepolet SA6-DX 0.033 in 0.961 in SD6-DX 0.037 in 1.017 in Loop A/D main steam line SA6-DY 0.032 in 0.848 in SD6-DY 0.034 in 0.889 in Loop A/D main steam line SA6-DZ 0.030 in 0.848 in SD6-DZ 0.031 in 0.889 in Loop A/D main steam line SA8-DY 0.057 in 1.871 in N/A N/A N/A RCIC vertical SA9-DX 0.030 in 1.116 in N/A N/A N/A RCIC normal to shield wall SB6-DX 0.041 in 2.048 in SC6-DX 0.041 in 2.048 in Loop B/C main steam line SB6-DY 0.036 in 1.736 in SC6-DY 0.036 in 1.736 in Loop B/C main steam line SB6-DZ 0.044 in 2.071 in SC6-DZ 0.044 in 2.071 in Loop B/C main steam line RA3-DX 0.030 in 0.476 in RB3-DX 0.030 in 0.476 in Loop A/B recirc RA3-DZ 0.030 in 0.406 in RB3-DZ 0.030 in 0.406 in Loop A/B recirc RA5-DX 0.030 in 0.240 in RB5-DX 0.030 in 0.240 in Loop A/B recirc RA5-DY 0.030 in 0.348 in RB5-DY 0.030 in 0.348 in Loop A/B recirc RA5-DZ 0.030 in 0.296 in RB5-DZ 0.030 in 0.296 in Loop A/B recirc RA7-S 14 x 10
-6in/in 889 x 10
-6in/in RA8-S 14 x 10
-6in/in 889 x 10
-6in/in Loop A recirc strain gauges RA9-S 23 x 10
-6in/in 1116 x 10
-6in/in RA10-S 23 x 10
-6in/in 1116 x 10
-6in/in Loop A recirc strain gauges
RBS USAR TABLE 14.2-4 PIPING VIBRATION OPERATING TRANSIENTS 1 of 1 August 1987 Transducer Displacement Level 2 Tolerance Displacement Level 1 Tolerance Transducer Displacement Level 2 Tolerance Displacement Level 1 Tolerance Location SA3-S 82x10
-6 in/in 164x10
-6 in/in SA4-S 82x10
-6 in/in 164x10
-6 in/in Loop A SRV sweepolet SA11-S 47x10
-6 in/in 95x10
-6 in/in SA12-S 47x10
-6 in/in 95x10
-6 in/in Loop A main steam pipe SB3-S 81x10
-6 in/in 162x10
-6 in/in SB4-S 81x10
-6 in/in 162x10
-6 in/in Loop B SRV sweepolet SC3-S 81x10
-6 in/in 162x10
-6 in/in SC4-S 81x10
-6 in/in 162x10
-6 in/in Loop C SRV sweepolet SD3-S 82x10
-6 in/in 164x10
-6 in/in SD4-S 82x10
-6 in/in 164x10
-6 in/in Loop D SRV sweepolet SA6-DX 0.050 in 0.100 in SD6-DX 0.033 in 0.065 in Loop A/D main steam line SA6-DY 0.040 in 0.080 in SD6-DY 0.028 in 0.055 in Loop A/D main steam line SA6-DZ 0.050 in 0.100 in SD6-DZ 0.020 in 0.040 in Loop A/D main steam line SA8-DY 0.070 in 0.140 in N/A N/A N/A RCIC vertical SA9-DX 0.020 in 0.040 in N/A N/A N/A RCIC normal to shield wall SB6-DX 0.065 in 0.130 in SC6-DX 0.065 in 0.130 in Loop B/C main steam line SB6-DY 0.063 in 0.125 in SC6-DY 0.063 in 0.125 in Loop B/C main steam line SB6-DZ 0.018 in 0.180 in SC6-DZ 0.018 in 0.180 in Loop B/C main steam line RA3-DX 0.032 in 0.065 in RB3-DX 0.032 in 0.065 in Loop A/B recirc RA3-DZ 0.033 in 0.065 in RB3-DZ 0.033 in 0.065 in Loop A/B recirc RA5-DX 0.030 in 0.060 in RB5-DX 0.030 in 0.060 in Loop A/B recirc RA5-DY 0.039 in 0.078 in RB5-DY 0.039 in 0.078 in Loop A/B recirc RA5-DZ 0.044 in 0.088 in RB5-DZ 0.044 in 0.088 in Loop A/B recirc RA7-S 163x10
-6 in/in 326x10
-6 in/in RA8-S 163x10
-6 in/in 326x10
-6 in/in Loop A recirc strain gauges RA9-S 163x10
-6 in/in 326x10
-6 in/in RA10-S 163x10
-6 in/in 326x10
-6 in/in Loop A recirc strain gauges