  • Distribution:
1. Boyer, Robert P
2. Carroll, Micha~ E Duke Energy DOCUMENT TRANSMITTAL FORM Date: 2/22/2017
  • Dorument Transmittal #: TR-NUC-MC-005385

Purpose:

~

1-----------------------------------------------------------------------------------------tR~easedBy:

3. Gardner, Troy R Facility: MCGUIRE NUCLEAR STATION Duke Energy
4. Mc Ginnis, Vickie L SUBJECT 13225 Hagers ferry Road
5. OPS HUMAN PERFORMANCE -

SLC 16.9.21 WATER LEVEL - SPENT FUEL STORAGE POOL Document Management

6. OPS TRNG MGR.

MG02DM

7. RESIDENT NRC INSPECT Huntersville. NC 28078 8..-SERV-BLDG.EILE-ROOM---- - ....._

( 9. U S NUC REG WASHINGTON, DC *; MNSDCRM@duke-energy.com

'-10:-USNRC---- . -~- -- . -

  • Page 1of1

'*.** . ,. ,._ ". .......,..........,.. :.-.:.:; 1 2 3 4 5 6 7 8 9 10 4t:N~*~<f!1~'.7H~N?~st~;J~(9J?ii~',oo~*:;~X$sii~o:~n(!.;;~t::r::'.0:::cir:r: m1E FYIIE FYIIE FYIIE FYIIE R&AIE PRINTILP FYIIE R&AIE R&AIE Remarks: RE\l. 155

  • 16.9 AUXILIARY SYSTEMS 16.9.21 Water Level- Spent Fuel Storage Pool Water Level - Spent Fuel Storage Pool 16.9.21
  • COMMITMENT At least 23 ft of water shall be maintained over the top of irradiated fuel assemblies seated in the storage racks.

AAPLICABILITY Whenever irradiated fuel as_semblies are being stored in the storage pool.

REMEDIAL ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A Spent fuel storage pool A1 Suspend all movement of Immediately water level not within fuel assemblies and crane limit. operations with loads in the fuel storage area.

A2 Restore spent fuel storage 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> pool water level to within limit.

TESTING REQUIREMENTS TEST FREQUENCY TR 16.9.21.1 Verify the water level in the spent fuel storage pool is 7 days

?. 23 ft over the top of irradiated fuel assemblies seated in the storage racks.

McGuire Units 1 and 2 16.9.21-1 Revision 155

  • BASES
  • Water Level- Spent Fuel Storage Pool 16.9.21 The restrictions on minimum water level ensure that sufficient water depth is available to apply an overall effective decontamination factor of 200 (i.e., 99.5% of the total iodine released from the damaged rods is retained in the water). The minimum water depth is consistent with the assumptions of the accident analysis.

REFERENCES

1. Stang, John (USNRC) to G. R. Peterson (Duke Energy Corporation), "McGuire Nuclear Station, Units 1 and 2, Issuance of Amendments Regarding Implementation of Alternative Source Term Methodology (TAC NOS. MC9746 and MC9747)",

December 22, 2006.

McGuire Units 1 and 2 16.9.21-2 Revision 155