ML16202A068

From kanterella
Jump to navigation Jump to search

Proposed Licensed Amendment Request Emergency Service Water Pump Allowed Outage Time Extension
ML16202A068
Person / Time
Site: Surry  Dominion icon.png
Issue date: 07/14/2016
From: Mark D. Sartain
Virginia Electric & Power Co (VEPCO)
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
16-263
Download: ML16202A068 (76)


Text

VIRGINIA ELECTRIC AND POWER COMPANY RICHMOND, VIRGINIA 2326I July 14, 2016 U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555-0001 VIRGINIA ELECTRIC AND POWER COMPANY SURRY POWER STATION UNITS 1 AND 2 PROPOSED LICENSE AMENDMENT REQUEST Serial No.:

SPS/LIC-CGL:

Docket Nos.:

License Nos.:

10CFR50.90 16-263 RO 50-280/281 DPR-32/37 EMERGENCY SERVICE WATER PUMP ALLOWED OUTAGE TIME EXTENSION Pursuant to 10 CFR 50.90, Virginia Electric and Power Company (Dominion) is submitting a license amendment request to revise Surry Power Station (Surry) Units 1 and 2 Technical Specification (TS) 3.14, "Circulating and Service Water Systems," to extend the Allowed Outage Time (AOT) for Emergency Service Water (ESW) pump inoperability. The proposed revision extends the TS 3.14.B AOT for one inoperable ESW pump from 7 to 14 days to provide operational flexibility for ESW pump maintenance and repairs.

A supporting probabilistic risk assessment (PRA) was performed for the proposed AOT change. The PRA concluded that the increase in risk associated with the proposed change is consistent with the Regulatory Guide (RG) 1.17 4 and RG 1.177 acceptance guidelines for a permanent TS AOT change. This PRA evaluation demonstrates that defense-in-depth will not be significantly impacted by changing the AOT for one inoperable ESW pump from 7 to 14 days. provides a discussion and assessment of the proposed change, including the results and conclusions from the supporting PRA. The marked-up and proposed pages for the TS and TS Basis are provided in Attachments 2 and 3, respectively. The TS Basis changes are provided for NRC information only. Attachment 4 provides a discussion of the technical adequacy of the PRA model.

We have evaluated the proposed amendment and have determined that it does not involve a significant hazards consideration as defined in 10 CFR 50.92. The basis for this determination is included in Attachment 1. We have also determined that operation with the proposed change will not result in any significant increase in the amount of effluents that may be released offsite or any significant increase in individual or cumulative occupational radiation exposure. Therefore, the proposed amendment is eligible for categorical exclusion from an environmental assessment as set forth in 1 O CFR 51.22(c)(9). Pursuant to 10 CFR 51.22(b), no environmental impact statement or environmental assessment is needed in connection with the approval of the proposed

Serial No.16-263 Docket Nos. 50-280/281 Page 2 of 3 change. The proposed TS change has been reviewed and approved by the Facility Safety Review Committee.

Dominion requests approval of the proposed change by July 31, 2017 with a 60-day implementation period.

Should you have any questions or require additional information, please contact Mr. Gary D. Miller at (804) 273-2771.

Respectfully,

~r-Mark D. Sartain Vice President-Nuclear Engineering Commitments contained in this letter: None Attachments:

1. Discussion of Change
2. Marked-up Technical Specifications and Basis Pages
3. Proposed Technical Specifications and Basis Pages
4. Technical Adequacy of the Probabilistic Risk Assessment Model COMMONWEAL TH OF VIRGINIA COUNTY OF HENRICO The foregoing document was acknowledged before me, in and for the County and Commonwealth aforesaid, today by Mr. Mark D. Sartain, who is Vice President -

Nuclear Engineering, of Virginia Electric and Power Company. He has affirmed before me that he is duly authorized to execute and file the foregoing document in behalf of that company, and that the statements in the document are true to the best of his knowledge and belief.

Acknowledged before me this /'/7J'day of

, 2016.

My Commission Expires:~,3/1 cJ.IJt8...

ltd*t.21ML Notary Public

cc:

U.S. Nuclear Regulatory Commission - Region II Marquis One Tower 245 Peachtree Center Avenue, NE Suite 1200 Atlanta, GA 30303-1257 State Health Commissioner Virginia Department of Health James Madison Building - ih floor 109 Governor Street Suite 730 Richmond, VA 23219 Ms. K. R. Cotton Gross NRC Project Manager - Surry U.S. Nuclear Regulatory Commission One White Flint North Mail Stop 08 G-9A 11555 Rockville Pike Rockville, MD 20852-2738 Dr. V. Sreenivas NRC Project Manager-North Anna U.S. Nuclear Regulatory Commission One White Flint North Mail Stop 08 G-9A 11555 Rockville Pike Rockville, MD 20852-2738 NRC Senior Resident Inspector Surry Power Station Serial No.16-263 Docket Nos. 50-280/281 Page 3 of 3 DISCUSSION OF CHANGE Virginia Electric and Power Company (Dominion)

Surry Station Units 1 and 2 Serial No.16-263 Docket Nos. 50-280/281

Serial No.16-263 Docket Nos. 50-280/281 Page 1 of 22 DISCUSSION OF CHANGE TABLE OF CONTENTS 1.0 Introduction 2.0 Description of Proposed Change 3.0 Technical Evaluation 3.1 Emergency Service Water Pumps 3.2 Evaluation and Application of the Extended Allowed Outage Time 4.0 Regulatory Evaluation 4.1 Applicable Regulatory Requirements 4.2 No Significant Hazards Consideration 5.0 Probabilistic Risk Assessment 5.1 Purpose 5.2 Introduction 5.3 Analysis 5.4 Results and Conclusions 6.0 Environmental Assessment 7.0 Conclusion

DISCUSSION OF CHANGE

1.0 INTRODUCTION

Serial No.16-263 Docket Nos. 50-280/281 Page 2 of 22 The proposed change revises Surry Power Station (Surry) Units 1 and 2 Technical Specification (TS) 3.14, "Circulating and Service Water Systems,".to extend the Allowed Outage Time (AOT) for Emergency Service Water (ESW) pump inoperability.

The proposed revision extends the TS 3.14.B AOT for one inoperable ESW pump from 7 to 14 days to provide operational flexibility for ESW pump maintenance and repairs.

In addition, the _TS 3.14 Basis is revised to reflect the AOT change from 7 to 14 days; the Basis change is being provided to the NRC for information.

A supporting Probabilistic Risk Assessment (PRA) was performed for the proposed AOT change.

The PRA concluded that the increase in risk associated with the proposed change is consistent with the Regulatory Guide (RG) 1.17 4 and RG 1.177 acceptance guidelines for a permanent TS AOT change.

2.0 DESCRIPTION

OF PROPOSED CHANGE TS 3.14.A.4 requires three ESW pumps to be operable and states that these pumps service both units simultaneously. The current TS 3.14.B AOT for one inoperable ESW pump is 7 days [with both units operating (RCS temperature or pressure greater than 350 degrees F or 450 psig, respectively)]. In addition, with one unit in cold shutdown with the combined. spent fuel pit and shutdown unit decay heat loads of 25 million BTU/hour or less, TS 3.14.B modifies the TS 3.14.A requirement to allow two ESW pumps to be operable, and one of the two remaining pumps to be inoperable for a period not to exceed 7 days. The pr6posed revision extends the TS 3.14.B AOT for one inoperable ESW pump from 7 to 14 days for the specified plant operating conditions (i.e., both units operating or one operating and one in cold shutdown with specified heat loads).

TS 3.14.B currently states the following, and the proposed changes are noted in bold bracketed text.

B. The requirements of Specifications 3.14.A.4 may be modified to allow one Emergency Service Water pump to remain inoperable for a period not to exceed 7 days [being revised to 14 days]. If this pump is not OPERABLE in 7 days [being revised to 14 days], then place both units in HOT SHUTDOWN within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and COLD SHUTDOWN within the next 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

Serial No.16-263 Docket Nos. 50-280/281 Page 3 of 22 The requirements of 3.14.A.4 may be modified to have two Emergency Service Water pumps OPERABLE with one unit in COLD SHUTDOWN with combined Spent Fuel pit and shutdown unit decay heat loads of 25 million BTU/HR or less. One of the two remaining pumps may be inoperable for a period not to exceed 7 days

[being revised to 14 days].

If this pump in not OPERABLE in 7 days [being revised to 14 days], then place the operating unit in HOT SHUTDOWN within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and COLD SHUTDOWN within the next 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

In addition, the TS 3.14 Basis includes the following sentence with the proposed change noted in bold bracketed text.

The allowed outage time of 7 days [being revised to 14 days] provides operational flexibility to allow for repairs up to and including replacement of an Emergency Service Water pump without forcing dual unit outages, yet limits the amount of operating time without the specified number of pumps.

This TS 3.14 Basis revision is being provided for the NRC's information.

3.0 TECHNICAL EVALUATION

3.1 Emergency Service Water Pumps The Circulating Water (CW) System draws water from the James River. to provide cooling water to the station. There are four CW pumps per unit located in the low level intake structure. Water is pumped from the river to the intake canal by the CW pumps and flows to the high level intake structure for each unit. CW flows by gravity from the high level intake to each condenser. The James River and the intake canal are the source of water for the Service Water (SW) System and provide the ultimate heat sink for Surry. SW branches from the CW System piping and flows to the various heat loads and services associated with Units 1 and 2. SW returns to the James River through a discharge tunnel from each unit and empties into a discharge canal serving both units.

The CW and SW Systems'. configuration is shown in Figure 1 (located at the end of ).

Three diesel-driven ESW pumps, which are also located in the low level intake structure, ensure that water can be provided to the intake canal when power is not available to the CW pumps. Each vertical, turbine-type pump is powered by a diesel engine connected to the pump by an angled reduction gear drive. The pumps are started from a local panel in the intake structure. A fuel oil storage tank located in the intake structure is sufficient to operate three pumps at full power for 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> and two pumps for an additional 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />.

Serial No.16-263 Docket Nos. 50-280/281 Page 4 of 22 The ESW pumps are sized to provide the design required make-up to the intake canal with the James River at the design low water level. The following criteria were used in sizing the ESW pumps:

1. In the event of a Loss of Coolant Accident (LOCA) and a total loss of station power, with the requirement that the unit that did not undergo the LOCA must also be cooled down, water flow is required to the recirculation spray heat exchangers, component cooling heat exchangers, other miscellaneous loads, and make-up for various non-cooling related high level canal inventory losses (e.g., seepage, evaporation, isolation valve leakage). This requires two of the three ESW pumps to be 'operated.
2. In the event of a design basis accident (LOCA in either unit and a total loss of station power), water flow is required to the recirculation spray heat exchangers, component cooling heat exchangers, other miscellaneous loads, and make-up for various non-cooling related high level canal inventory losses. This condition, assuming one unit is in cold shutdown with the combined spent fuel pit and shutdown unit decay heat loads of 25 million BTU/hour or less, requires one ESW pump in operation.
3. In the event of a loss of station power in two units, component cooling heat exchangers would be required to cool down the units.
  • Additional flow would be required for other miscellaneous loads and make-up for various non-cooling related high level canal inventory losses. This scenario requires two of the three ESW pumps to be operated.

3.2 Evaluation and Application of the Extended Allowed Outage Time As stated in Section 3.1 above, the ESW pumps ensure that water can be provided to the intake canal when power is not available to the CW pumps.

The proposed extension of the AOT for one inoperable ESW pump from 7 to 14 days does not impact the design function of the ESW pumps. In addition, the number of ESW pumps required to be operable for the specified plant operating conditions is not impacted by the proposed AOT extension. Furthermore, as detailed in Section 5.0 below, the supporting PRA for the proposed AOT change concluded that the increase in risk is acceptable, and the PRA evaluation demonstrates that defense-in-depth will not be significantly impacted by changing the AOT for one inoperable ESW pump from 7 to 14 days.

A project has been initiated to replace each of the ESW pump diesel foundations and couplings.

The duration of each foundation/coupling replacement is approximately 7 days, and these replacement activities are currently scheduled to be completed during refueling outages. The proposed AOT of 14 days will permit the planning of future ESW pump maintenance and repair activities to include increased contingency time, which in turn will allow ESW pump maintenance and repair activities to be conducted in a more reasonable and controlled manner. Furthermore, a 14-day AOT will reduce challenges

Serial No.16-263 Docket Nos. 50-280/281 Page 5 of 22 to the current 7-day TS AOT and will avoid the potential for a dual unit outage for future ESW pump maintenance/repair activities.

4.0 REGULATORY EVALUATION

4.1 Applicable Regulatory Requirements The regulations in Appendix A to Title 10 of the Code of Federal Regulations (10 CFR)

Part 50 establish minimum principal design criteria for water-cooled nuclear power plants, while 10 CFR 50 Appendix B and the licensee quality assurance programs establish quality assurance requirements for the design, manufacture, construction, and operation of structures, systems, and components. The current regulatory requirements of 10 CFR 50 Appendix A that are applicable to the ESW pump function of providing water to the intake canal if the CW pumps are not available during accident conditions include:

General Design Criteria (GDC) 1 (Quality Standards and Records), 38 (Containment Heat Removal), and 44 (Cooling Water).

During the initial plant licensing of Surry Units 1 and 2, it was demonstrated that the design of the CW and SW Systems met the regulatory requirements in place at that time. The GDC included in Appendix A to 10 CFR 50 did not become effective until May 21, 1971. The Construction Permits for Surry Units 1 and 2 were issued prior to May 21, 1971; consequently, the Surry Units 1 and 2 were not subject to current GDC requirements (SECY-92-223, dated September 18, 1992).

Section 1.4 of the Surry Units 1 and 2 Updated Final Safety Analysis Report (UFSAR) discusses compliance with the GDC published in 1967 (Draft GDC), and the UFSAR discussion demonstrates that Surry Units 1 and 2 meet the intent of these criteria. The draft GDC pertinent to the proposed change are addressed below.

Quality Standards (Criterion 1 - draft)

Those systems and components of reactor facilities that are essential to the prevention of accidents which could affect the public health and safety or to the mitigation of their consequences are designed, fabricated, and erected in accordance with quality standards that reflect the importance of the safety function to be performed.

Where generally recognized codes or standards on design, materials, fabrication, and inspection are used, they shall be identified.

Where adherence to such codes or standards does not suffice to assure a quality product in keeping with the safety function, they shall be supplemented or modified as necessary. A showing of sufficiency and applicability of codes, standards, quality assurance programs, test procedures, and inspection acceptance levels used is required.

Design Conformance Serial No.16-263 Docket Nos. 50-280/281 Page 6 of 22 Structures, systems, and components important to safety are designed, fabricated, erected, and tested to quality standards commensurate with the importance of the safety functions to be performed.

The Quality Assurance Program was established to provide assurance that safety-related structures, systems, and components satisfactorily perform their intended safety functions.

Engineered Safety Features Performance Capability (Criterion 41 - draft)

Engineered safety features, such as emergency core cooling and containment heat removal systems, shall provide sufficient performance capability to accommodate partial loss of installed capacity and still fulfill the required safety function. As a minimum, each engineered safety feature shall provide this required safety function assuming a failure of a single active component.

Design Conformance Engineered safeguards, such as the SI System and the containment heat removal system, provide sufficient performance capability to accommodate the failure of any single active component without any undue risk to the health and safety of the public. The overall capability of the engineered safeguards meets the suggested requirements of 1 OCFR50.67 or RG 1.183, as applicable, for the occurrence of any rupture of a reactor coolant or Main Steam System pipe, including the double-ended rupture of a reactor coolant pipe, known as the design-basis accident.

Containment Heat Removal Systems Where active heat removal systems are needed under accident conditions to prevent exceeding containment design pressure, at least two systems, preferably of different principles, each with full capacity, are provided.

Design Conformance Four separate containment recirculation spray subsystems, each with approximately 50% capacity, serve to remove heat from the containment after a LOCA.

Each subsystem contains one deepwell-type pump. In two subsystems, the recirculation spray pumps are located inside the containment. In the other two subsystems, the recirculation spray pumps are located in the containment auxiliary structures and are accessible for servicing at all times.

Quality Assurance Serial No.16-263 Docket Nos. 50-280/281 Page 7 of 22 Quality assurance criteria provided in 10 CFR Part 50, Appendix B, that apply to the systems and components pertinent to the proposed change include: Criteria Ill, V, XI, XVI, and XVII. Criteria Ill and V require measures to ensure that applicable regulatory requirements and the design basis, as defined in 10 CFR 50.2, "Definitions," and as specified in the license application, are correctly translated into controlled specifications, drawings, procedures, and instructions. Criterion XI requires a test program to ensure that the subject systems will perform satisfactorily in service and requires that test results shall be documented and evaluated to ensure that test requirements have been satisfied. Criterion XVI requires measures to ensure that conditions adverse to quality, such as failures, malfunctions, deficiencies, deviations, defective material and equipment, and nonconformances, are promptly identified and corrected, and that significant conditions adverse to quality are documented and reported to management.

Criterion XVII requires maintenance of records of activities affecting quality.

4.2 No Significant Hazards Consideration The proposed change revises Surry Power Station (Surry) Units 1 and 2 Technical Specification (TS) 3.14, "Circulating and Service Water Systems," to extend the Allowed Outage Time (AOT) for Emergency Service Water (ESW) pump inoperability.

TS 3.14.A.4 requires three ESW pumps to be operable and states that these pumps service both units simultaneously. The current TS 3.14.B AOT for one inoperable ESW pump is 7 days [with both units operating (RCS temperature or pressure greater than 350 degrees F or 450 psig, respectively)]. In addition, with one unit in cold shutdown with the combined spent fuel pit and shutdown unit decay heat loads of 25 million BTU/hour or less, TS 3.14.B modifies the TS 3.14.A requirement to allow two ESW pumps to be operable, and one of the two remaining pumps to be inoperable for a period not to exceed 7 days. The proposed revision extends the TS 3.14.B AOT for one inoperable ESW pump from 7 to 14 days for the specified plant operating conditions (i.e., both units operating or one operating and one in cold shutdown with specified heat loads). The proposed extended AOT will provide operational flexibility to accommodate maintenance and repairs.

A supporting probabilistic risk assessment (PRA) was performed for the proposed AOT change. The PRA concluded that the increase in risk associated with the proposed change is consistent with the Regulatory Guide (RG) 1.17 4 and RG 1.177 acceptance guidelines for a permanent TS AOT change. This PRA evaluation demonstrates that defense-in-depth will not be significantly impacted by changing the AOT for one inoperable ESW pump from 7 to 14 days. Furthermore, no enhancements, procedure revisions, or compensatory actions are recommended as a result of the RG 1.177 Tier 2 evaluation.

Serial No.16-263 Docket Nos. 50-280/281 Page 8 of 22 Dominion has evaluated whether a significant hazards consideration is involved with the proposed amendment by focusing on the three standards set forth in 1 O CFR 50.92, "Issuance of amendment," as discussed below:

1. Does the proposed change involve a significant increase in the probability or consequences of an accident previously evaluated?

Response: No.

The design function of the ESW pumps is to ensure that water can be provided to the intake canal (i.e., the ultimate heat sink) when power is not available to the Circulating Water (CW) pumps.

The proposed extension of the AOT for *one inoperable ESW pump from 7 to 14 days does not impact the design function of the ESW pumps. In addition, the number of ESW pumps required to be operable for the specified plant operating conditions is not impacted by the proposed AOT extension.

As a result, the proposed change does not involve a significant increase in the probability or consequences of an accident previously evaluated.

2. Does the proposed change create the possibility of a new or different kind of accident from any accident previously evaluated?

Response: No.

The proposed change does not involve a physical alteration of the plant (i.e., no new or different type of equipment will be installed) and does not impact plant operation.

Furthermore, the proposed change does not impose any new or different requirements that could initiate an accident. The proposed change does not alter

  • assumptions made in the safety analysis and is consistent with the safety analysis assumptions. Therefore, the proposed change does not create the possibility of a new or different kind of accident from any accident previously evaluated.
3. Does the proposed change involve a significant reduction in a margin of safety?

Response: No.

The proposed change does not adversely affect any current plant safety margins or

  • the reliability of the equipment assumed in the safety analysis.

There are no changes being made to any safety analysis assumptions, safety limits, or limiting safety system settings that would adversely affect plant safety as a result of the proposed change. Furthermore, as noted above, a supporting PRA was performed for the proposed AOT change.

The PRA concluded that the increase in risk associated with the proposed change is consistent with the RG 1.17 4 and RG 1.177 acceptance guidelines for a permanent TS AOT change.

This PRA evaluation demonstrates that defense-in-depth will not be significantly impacted by changing

Serial No.16-263 Docket Nos. 50-280/281 Page 9 of 22 the AOT for one inoperable ESW pump from 7 to 14 days. Therefore, the proposed change does not involve a significant reduction in a margin of safety.

Based on the above, Dominion concludes that the proposed change presents no significant hazards consideration under the standards set forth in 10 CFR 50.92(c), and, accordingly, a finding of "no significant hazards consideration" is justified.

5.0 PROBABILISTIC RISK ASSESSMENT 5.1 Purpose The purpose of this assessment is to utilize the Surry PRA to evaluate the impact on Core Damage Frequency (CDF) and Large, Early Release Frequency (LERF) for the ESW pump AOT extension from 7 to 14 days.

Using guidelines prescribed in Regulatory Guides (RGs) 1.174 and 1.177, this assessment evaluates the risk of changing TS 3.14.B to allow a single ESW pump to be unavailable for up to 14 days.

5.2 Introduction The 8007 Aa PRA model allows analysis of the conditional risk at Surry when one or more ESW pumps are unavailable to perform safety related functions utilizing a detailed probabilistic assessment of risk from internal events and internal flooding hazards at power.

This risk evaluation is supplemented with qualitative insights to assess shutdown, fire, seismic, and other external risks.

HG 1.177 identified a three-tiered approach for licensees to evaluate the risk associated with proposed TS Completion Time (CT) changes. Tier 1 is an evaluation of the impact on plant risk of the proposed TS change as expressed by the change in core damage frequency (~CDF), the incremental conditional core damage probability (ICCDP), the change in large early release frequency (.6LERF), and the incremental conditional large early release probability (ICLERP). Tier 2 is an identification of potentially high-risk configurations that could exist if equipment in addition to that associated with the change were to be taken out of service simultaneously or other risk-significant operational factors such as concurrent system or equipment testing were also involved. The objective of this part of the evaluation is to ensure that appropriate restrictions on dominant risk-significant configurations associated with the change are in place. Tier 3 is the establishment of an overall configuration risk management program (CRMP) to ensure that other potentially lower probability, but nonetheless risk-significant, configurations resulting from maintenance and other operational activities are identified and compensated for.

t Diesel.;:

I Fuel Supply Lina Fual R9tum Una Shatt BrgOll cooler l

Notes: 1. 1-SW-P-1BAnd-1CSlmllar 2

" ~:~~~~1~\\t 1

0~\\~~~ 5~:'iSB Noted STR*,---,

4A

,/\\....,

FE-121A

{AnnuOO.r)

Drain SetVice Water Fuel Oil Sullsyslem

(~f),,

\\iY ~

~To Intake Canal Serial No.16-263 Docket Nos. 50-280/281 Page 10 of 22 Figure 2 - Emergency Service Water Subsystem for Emergency Service Water Pump 1-SW-P-1A

[This figure is not a controlled station drawing and is provided for illustration purposes only.]

The ESW System provides a supply of water to the intake canal in the event of CW pump failure.

Figure 2 above illustrates the ESW subsystem for ESW pump 1-SW-P-1 A The subsystem consists of the following major components:

1. three ESW pumps,
2. three ESW diesels, and
3. the SW Fuel Oil Subsystem.

The entire ESW subsystem is housed in the Emergency Service Water House on the Low-Level Intake Structure and is operated locally. Each ESW pump takes suction on the river water in one screenwell at the Low-Level Intake Structure and discharges into

Serial No.16-263 Docket Nos. 50-280/281 Page 11 of 22 the intake canal. Pump 1A is in CW pump Screenwell 1 D, Pump 1 B is in Screenwell 2A, and Pump 1 C is in Screenwell 2B. Each vertical, turbine-type pump is powered by a diesel engine connected to the pump by an angled reduction gear drive. The capacity of each pump is 16,200 gpm at a discharge head of 45.5 feet.

The diesel is started by a 24V de electric motor that is actuated by a local pushbutton.

A 24V de battery on each ESW diesel provides power to the starting motor and the control circuit for the engine. Each battery is kept charged by its own battery charger and may also be charged by an alternator mounted on the diesel.

The intake canal is part of the flowpath for both the CW System and the SW System and acts as a reservoir for these systems. The intake canal is concrete lined along its 1.7-mile length. The canal walls slope from top to bottom; the average width of the canal is 125 feet. The bottom of the canal slopes from an elevation of 6 feet 8 inches at the Low-Level Intake end to an elevation of 5 feet at the High-Level Intake. Here, the bottom of the canal slopes sharply to the base of the High-Level Intake Structure at 0 feet, 8 inches. Water level in the intake canal is normally kept at an elevation of approximately 25 to 30 feet; CW flows through the intake canal and to the condensers by gravity.

In the event of a large break LOCA coincident with a loss of reserve station electrical power (Design Basis Accident or OBA), the SW supply header isolation motor operated valves (MOVs) to Bearing Cooling (BC), Component Cooling (CC), and Turbine Building SW, and the condenser CW MOVs shut, and the Recirculation Spray heat exchanger (RSHX) MOVs open. This ensures that sufficient water is available in the intake canal to provide the initial 15,600 gpm required for the RSHX heat load of approximately 3E8 BTU/hour. The amount of water in the canal in conjunction with the operation of the ESW pumps is sufficient to maintain a supply of cooling water to the_ RSHXs in the event of a OBA SW to CC heat exchangers can be placed in service within procedural restrictions to cool down the non-accident unit.

If canal isolation is not complete, or the ESW pumps do not start, there may be certain sequences which result in canal drainage below the level required for SW flow to various loads. There are many combinations of isolation failures, SW pump failures, and SW load requirements.

During the development of Surry's Individual Plant Examination (IPE), calculations were performed and an event tree was constructed to identify combinations of failures and successes which form success criteria for intake canal level in Surry's PRA model. The IPE has established best estimate success criteria for intake canal level that are less conservative than design basis criteria in order to reflect the as-built, as-operated plant. PRA success criteria for intake canal level are discussed further in the analysis section.

5.3 Analysis Inputs The following inputs are used for this assessment:

Surry Average Maintenance PRA model S007 Aa, RG 1.174, RG 1.177, and CAFTA code suite.

Risk Impact Evaluation Serial No.16-263 Docket Nos. 50-280/281 Page 12 of 22 The NRC staff has identified a three-tiered approach in RG 1.177 for licensees to evaluate the risk associated with proposed TS CT changes. The following sections document the three-tiered evaluation for the ESW pump AOT extension from 7 to 14 days.

RG 1.177 PRA Quality Evaluation RG 1.177 contains the following discussion of PRA Technical Adequacy:

The technical adequacy of the PRA must be compatible with the safety implications of the TS change being requested and the role that the PRA plays in justifying that change. That is, the more the potential change in risk or the greater the uncertainty in that risk from the requested TS change, or both, the more rigor that must go into ensuring the technical adequacy of the PRA. This applies to Tier 1 (above), and it also applies to Tier 2 and Tier 3 to the extent that a PRA model is used.

Regulatory Guide 1.200 describes one acceptable approach for determining whether the technical adequacy of the PRA, in total or the parts that are used to support an application, is sufficient to provide confidence in the results such that the PRA can be used in regulatory decisionmaking for light-water reactors.

A detailed discussion and evaluation of PRA quality of the S007 Aa model with respect to this application can be found in Attachment 4.

RG 1.177Tier1 Analysis Regulatory Guide 1.177 contains the following discussion concerning Tier 1 Analysis:

In Tier 1, the licensee should assess the impact of the proposed TS change on GDF, ICCDP, LERF, and ICLERP.

To support this assessment, two aspects need to be considered: (1) the validity of the PRA and (2) the PRA insights and findings.

The

Serial No.16-263 Docket Nos. 50-280/281 Page 13 of 22 licensee should demonstrate that its PRA is valid for assessing the proposed TS changes and identify the impact of the TS change on plant risk.

TS conditions addressed by CTs are entered infrequently and are temporary by their very nature. However, TS do not typically restrict the frequency of entry into conditions addressed by CTs.

Therefore, the following TS acceptance guidelines specific to permanent CT changes are provided for evaluating the risk associated with the revised CT, in addition to those acceptance guidelines given in Regulatory Guide 1. 17 4:

The licensee has demonstrated that the TS CT change has only a small quantitative impact on plant risk.

An JCCDP of less than 1.ox10-6 and an ICLERP of less* than 1.ox10-7 are considered small for a single TS condition entry. (Tier 1).

Regulatory Guide 1.17 4 Acceptance Criteria are as follows:

When the calculated increase in GDF is very small, which is taken as being less than 1 o-6 per reactor year, the change will be considered regardless of whether there is a calculation of the total CDF (Region Ill).

When the calculated increase in CDF is in the range of 1 o-6 per reactor year to 10-5

  • per reactor year, applications will be considered only if it can be reasonably shown that the total GDF is Jess than 10-4 per reactor year (Region//).

Applications that result in increases to CDF above 10-5 per reactor year (Region /)

. would not normally be considered.

Acceptance criteria for LERF are structured similarly at an order of magnitude less (1.0E-7, etc).

Tier 1 Analysis Assumptions The PRA model 8007 Aa is valid for performing this assessment.

For the purposes of ~CDF and ~LERF calculations, this assessment assumes that overall annual ESW pump unavailability will increase by 100% (factor of 2) as a result of the proposed change. Analysis results are not sensitive to ESW pump unavailability.

ESW pump unavailability input into the Mitigating Systems Performance Indicator from the period February 2013 to January 2016 was taken to be the current, average unavailability for ESW pumps input into this analysis.

For the purposes of ICCDP/ICLERP calculations, ESW Pump A may be used as a surrogate for ESW Pumps B and c. because of symmetry in the plant configuration.

Tier 1 Analysis Results ESW pumps are explicitly modeled in the average maintenance model 8007 Aa.

Therefore, a ~CDF and ~LERF for the proposed change to AOTs for ESW pumps may

Serial No.16-263 Docket Nos. 50-280/281 Page 14 of 22 be directly calculated from the model by calculating CDF/LERF results with increased unavailability on ESW pumps (refer to second bulleted assumption). Incremental core damage and large early release probabilities for a single 14 day period with a single ESW pump unavailable are also calculated. Some asymmetry exists between Surry Units 1 and 2 with respect to emergency power supplies and power dependencies in the SW system; therefore, the risk to each unit is explicitly calculated.

(2x) ESWP Unavailability Single 14 day TS entry Table 1: RG 1.177 Tier 1 Analysis Results Ul 6CDF 4.07E-11 Ul ICCDP 1.32E-11 RG 1.177 U2 6CDF 6CDF Criteria 5.86E-11 U2 ICCDP 1.99E-11 1.00E-06 RG 1.177 ICCDP Criteria 1.00E-06 Ul 6LERF 3.56E-16 Ul ICLERP 3.41E-17 U2 6LERF 1.38E-15 U2 ICLERP 3.24E-16 RG 1.177 6LERF Criteria 1.00E-07 RG 1.177 I CLE RP Criteria 1.00E-07 Extensive margin exists to RG 1.177 acceptance criteria.

Cutsets for these configurations were reviewed and are discussed below.

Probabilistic risk models show that the probability of a OBA (Design Basis Large Break LOCA with coincidental LOOP) occurring within a calendar year is exceptionally low (approximately 1.0E-8/yr in S007Aa).

The existing canal inventory is considered sufficient to supply the RSHXs over the 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> PRA mission time if the following functions are satisfied:

CC SW is successfully throttled by operators using procedure O-AP-12.01 "Loss of Intake Canal Level" guidance.

BC SW MOVs and CW waterbox MOVs are successful in isolating non-essential CW/SW loads.

In the event operator action to throttle CC SW fails, two or more ESW pumps are relied upon in order to provide a heat sink to maintain containment integrity and remove decay heat through the RSHXs. This event frequency is so low that it does not show up as a significant accident sequence in this analysis.

A more likely scenario where ESW pumps may be required to maintain canal inventory is loss of offsite power and loss of CW pump events. Similar to a Design Basis LOCA scenario, the existing canal inventory is considered sufficient to supply CC heat exchangers and SW loads to Main Control Room (MCR) chillers and Charging Service

Serial No.16-263 Docket Nos. 50-280/281 Page 15 of 22 Water pumps over the 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> PRA mission time as long as the following functions are satisfied:

CC SW is successfully throttled by operators using procedure O-AP-12.01 "Loss of Intake Canal Level" guidance.

BC SW MOVs and CW waterbox MOVs.are successful in isolating non-essential CW/SW loads.

If one of these requirements is not satisfied, the ability to supply SW loads over the 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> PRA mission time is challenged, and one or more ESW pumps would be required to operate in conjunction with operator action to conserve canal inventory in order to supply SW to the intake canal.

If a single waterbox does not isolate, the

. vacuum breakers on the waterbox must be opened prior to the canal level reaching the bottom of the condenser tube sheet (elevation 11' 9") or the canal will continue to drain through the condenser by siphon and water supply to SW will be unavailable.

ESW pumps are not involved in core damage sequences that involve containment bypass, such as Steam Generator Tube Rupture (SGTR), and are only credited in unlikely circumstances to supply SW to RSHXs to remove decay heat and maintain containment integrity. Therefore, ESW pumps do not play a significant role in LERF accident sequences for Surry.

The results of this analysis indicate that the potential increase in core damage probability due to the proposed change is very small and satisfies the Region Ill criteria of RG 1.177 Tier 1 analysis. [Refer to Table 1 above.]

Shutdown Risk Evaluation In cases where there is no probabilistic shutdown PRA model available for evaluating the risk impact of a proposed change, as is currently the case with the Surry PRA, a qualitative evaluation process may be applied to assess shutdown risk. In general, this approach involves determining whether or not the proposed change affects functions that are credited in OU-AA-200, 'Shutdown Risk Management,' and then considering what impacts the application may have on shutdown defense-in-depth, in particular the following shutdown key safety functions:

Decay Heat Removal, Reactor Coolant System/Spent Fuel Pool Inventory Control, Reactivity Control, Electrical Power, Spent Fuel Pool Cooling, and Containment Integrity.

The ESW subsystem does not directly support any of the shutdown key safety functions.

The at-power risk evaluation bounds the shutdown risk evaluation, since being at shutdown conditions lowers potential heat loads/inventory requirements on the intake canal, and no unique vulnerabilities to intake canal level are introduced by being in a shutdown configuration.

Serial No.16-263 Docket Nos. 50-280/281 Page 16 of 22 It is concluded that the proposed change has negligible impact on shutdown CDF and LERF.

Internal Fire Hazard Evaluation Since a full-scope fire PRA model has not been developed for Surry, the Individual Plant Examination for External Events (IPEEE) and the Fire Contingency Action (FCA) procedures are used to evaluate the impact of extending the AOT for configurations with one ESW pump unavailable on fire risk. The IPEEE identified four areas as significant contributors to the fire CDF. The areas which were identified include the Cable Vault and Tunnel (CVT), the Emergency Switchgear Room (ESGR), the MCR, and the Normal Switchgear Room (NSGR).

Since fires in other areas are not significant contributors to fire risk as characterized by the IPEEE, they are screened from further consideration. This includes fires at the intake structure. In both the Appendix R report and IPEEE analysis, the ESW pumps and CW pumps are considered to be in separate areas, so a fire that disables ESW pumps will not affect CW pumps, and a fire that disables CW pumps will not affect ESW pumps. A fire that damages all 8 CW pumps has the same consequence to nuclear safety as other loss of CW initiators and is adequately characterized by the internal° events evaluation for loss of CW.

It is assumed that a fire in any area, which does not cause sufficient damage to enter the respective FCA procedure, can be characterized as a general transient and is adequately addressed by the internal events analysis.

For fires in these four areas, loss of offsite power is not assumed in the IPEEE analysis.

Fire damage in these areas does not affect the feeder power to the 4160 V power to the CW pumps at the Low Level Intake Structure so CW pumps remain available. The impact of the proposed change in ESW purnp AOT on fire risk for these scenarios is very low given the low frequency of failure combinations that involve all of the following events:

fire in one of these areas, failure of all CW pumps (random LOOP or other failure),

failure of CW/SW isolation, and failure of the in-service ESW pumps.

Significant core damage sequences in the IPEEE fire analysis were reviewed, and it was confirmed that ESW pumps do not perform a function in these sequences.

Based on the review of the risk significant fire areas, the expected equipment damage, and the fire strategies used to achieve SSD, it is concluded that the consequence of having a single ESW pump unavailable due to maintenance during these scenarios is

Serial No.16-263 Docket Nos. 50-280/281 Page 17 of 22

  • negligible. These insights demonstrate the impact of the ESW AOT change on the overall fire risk is small and may be screened from further evaluation.

Seismic Hazard Evaluation Generic Letter (GL) 88-20 Supplement 4 was issued by the NRC in June 1991. This GL and NUREG-1407 requested each nuclear plant licensee to perform an IPEEE. In a December 1991 letter to the NRC, Surry identified the planned approach to address the IPEEE. For non-seismic external events and fires, the IPEEE effort was completed and a report was submitted to the NRC in December 1997.

Surry was categorized in NUREG-1407 as a focused scope plant.

As identified in Surry's December 1991 letter, the Seismic Margins Method (SMM) developed by Electric Power Research Institute (EPRI) with enhancements was selected for Surry. A completion schedule for IPEEE - Seismic was initially provided by Surry in its September 1992 letter to the NRC which also noted that elements of the effort to resolve IPEEE - Seismic, notably plant walkdowns, will be integrated with the resolution of Unresolved Safety Issue (USI) A-46 identified in NRC's Supplement 1 to GL 87-02 of May 1992.

In September 1995, the NRC issued Supplement 5 to GL 88-20. This letter gave further guidance on the basis for selection of components that needed capacity evaluation.

Based on GL 88-20, Supplement 5, Surry submitted a revised approach to the NRC in November 1995.

This approach, while still retaining the Seismic Probabilistic Risk Assessment (SPRA) methodology and treating Surry as a focused scope plant, identified areas where screening and judgment by experienced and trained engineers would eliminate the need for performing capacity calculations for rugged components, structures, and systems and would require such evaluations only for weaker and critical components.

The IPEEE - Seismic program at Surry has been performed in accordance with the SPRA methodology for a focµsed plant and Surry's stated commitments.

In February 1996, a peer review was conducted to assess the implementation of the IPEEE-Seismic program at Surry. This review included walkdown of about 15% of the items representing all classes of equipment in the Safe Shutdown Equipment List.

Although a few open issues were noted at the time of the review, the reviewer concluded that the Seismic Review Teams involved did an excellent seismic walkdown review at Surry.

In summary, the IPEEE-Seismic program, integrated with the USI A-46 effort, resulted in several plant improvements and design modifications.

The SPRA quantification concluded that no severe accident vulnerabilities exist at Surry from a potential seismic event.

No other cost beneficial upgrade can be performed to improve the seismic margin and the core damage frequency of the plant.

Serial No.16-263 Docket Nos. 50-280/281 Page 18 of 22 The Surry Seismic Probability Risk Assessment Pilot Plant Report was reviewed, and this license amendment request (LAR) does not impact the conclusions drawn in that report. The following is a discussion of SPRA quantification results from that report.

The dominant Seismic PRA sequence (52%) involves the failure of the turbine building starting a chain of events that fails SW. Since the power cables to the CW isolation valves run through cable trays in the turbine building, it was assumed that the failure of the steel superstructure would fail the valve cables, even though they are in the concrete portion of the turbine building below ground elevation. Failure of the cables prevents the CW isolation valves from closing, the canal will rapidly drain through the CW lines, SW cooling will be lost, and core damage is assumed (ESW pump capacity is not sufficient to make up for total failure of CW isolation). The proposed change does not have an adverse impact on this sequence.

25.7% of Surry seismic risk is associated with seismic-induced SW flooding. This risk is dominated by seismic-induced ruptures of BC heat exchangers. The proposed change does not have an adverse effect on seismic-induced flooding sequences.

Other significant sequences involving seismic-induced transients and LOOPs were reviewed, and it was determined that ESW pumps do not play a role in these sequences. Therefore, it is concluded that the proposed change has a negligible impact on seismic risk and is screened from further evaluation.

Other External Hazards Evaluation Other external hazards, as identified by NUREG/CR-2300, "A Guide to the Performance of Probabilistic Risk Assessments for Nuclear Power Plants," and NUREG/CR-4839 "Methods for External Event Screening Quantification: Risk Methods Integration and Evaluation Program (RMIEP) Methods Development," have been taken into consideration.

These hazards were evaluated by Dominion in response to GL 88-20, Supplement 4. The analysis utilized the method and results obtained by NUREG/CR-4550, "Analysis of Core Damage Frequency from Internal Events:

Methodology Guidelines, Volume 1," supplemented with information from the Surry UFSAR. Other external events, except external flooding, aircraft impacts, and pipeline accidents, were screened out based on the UFSAR and NUREG/CR-4550 information.

A bounding analysis based on the methods used by NUREG/CR-4550 was performed for the effects of aircraft impacts and pipeline accidents, and these initiators were shown to have a small frequency of occurring and are, therefore, screened from further consideration.

External flooding was evaluated separately and also shown to be a non-significant contributor to core damage risk. Therefore, it can be concluded that non-seismic external events do not pose a significant risk to the safe operation of Surry.

Serial No.16-263 Docket Nos. 50-280/281 Page 19 of 22 Based on the above, other External Events have been screened from further evaluation in this LAR.

RG 1.177 Tier 2: Avoidance of Risk Significant Plant Configurations RG 1.177 contains the following discussion concerning Tier 2 analysis:

The licensee should provide reasonable assurance that risk-significant plant equipment outage configurations will not occur when specific plant equipment is out of service consistent with the proposed TS change.

An effective way to perform such an assessment is to evaluate equipment according to its contribution to plant risk (or safety) while the equipment covered by the proposed CT change is out of service.

Evaluation of such combinations of equipment out of service against the Tier 1 ICCDP and ICLERP acceptance guidelines could be one appropriate method of identifying risk-significant configurations. Once plant equipment is so evaluated, an assessment can be made as whether certain enhancements to the TS or procedures are needed to avoid risk significant plant configurations. In addition, compensatory actions that can mitigate any corresponding increase in risk (e.g., backup equipment, increased surveillance frequency, or upgraded procedures and training) should be identified and evaluated. Any changes made to the plant design or operating procedures as a result of such a risk evaluation (e.g., required backup equipment, increased surveillance frequency, or upgraded procedures and training required before certain plant system configurations can be entered) should be incorporated into the analyses utilized for TS changes as described under Tier 1 above.

A detailed review of PRA importance metrics (Risk Achievement Worth, Fussell-Vesely) from the Tier 1 PRA Model did not reveal any risk significant maintenance configurations when one ESW pump is unavailable.

No enhancements, procedure revisions or compensatory actions are recommended from the Tier 2 evaluation~

RG 1.177 Tier 3: Risk-Informed Plant Configuration Control and Management Dominion's 10 CFR 50.65(a)(4) program fully satisfies the recommendations of RG 1.177 Tier 3. RG 1.177 Section 2.3 states that:

The licensee should develop a program that ensures that the risk impact of out-of-service equipment is appropriately evaluated prior to performing any maintenance activity.

A viable program would be one that is able to uncover risk-significant plant equipment outage configurations in a timely manner during normal plant operation.

The Dominion 10 CFR 50.65(a)(4) program performs PRA analyses of planned maintenance configurations in advance.

The ESW System is included in the 10 CFR 50.65(a)(4) scope and its removal from service is monitored, analyzed, and

Serial No.16-263 Docket Nos. 50-280/281 Page 20 of 22 managed. Configurations that approach or exceed the NUMARC 93-01 risk limits are identified and either avoided or addressed by risk management actions.

Emergent configurations are identified and analyzed by the on-shift staff for prompt determination of whether risk management actions are needed. The configuration analysis and risk management processes are fully proceduralized in compliance with the requirem~nts of 1 O CFR 50.65(a)(4). Dominion's (a)(4) program is implemented with station procedures WM-AA-300, "Work Management," and NF-AA-PRA-370, "MRule (a)(4) Risk Monitor Guidance."

To support Dominion's 1 O CFR 50.65(a)(4) program, a dedicated PRA model is used to perform configuration risk analysis. The model uses the S007 Aa model as a framework with some adjustments to optimize the model for configuration risk calculations. The model allows for quantitative Level 1 and Level 2 (LERF) assessments of internal events and internal floods hazards for at-power configurations. Risk during shutdown configurations and risks due to other hazards are assessed qualitatively. Changes in plant configuration or PRA model features are dispositioned and managed by Dominion's PRA configuration control process. Procedures are in place to ensure that actions are taken as necessary to qualitatively assess configurations outside the scope of the PRA model.

5.4 Results and Conclusions The increase in risk associated with the proposed TS change is consistent with the RG 1.174 and RG 1.177 acceptance guidelines for a permanent TS CT change. This evaluation demonstrates that nuclear defense-in-depth will not be significantly impacted by allowing a single ESW pump to be unavailable for up to 14 days.

6.0 ENVIRONMENTAL ASSESSMENT The proposed change will revise a requirement with respect to installation or use of a facility component located within the restricted area, as defined in 10 CFR 20.

Specifically, the proposed revision extends the TS 3.14.B AOT for one inoperable ESW pump from 7 to 14 days for the specified plant operating conditions (i.e., both units operating or one operating and one in cold shutdown with specified heat loads).

However, the proposed change does not involve (i) a significant hazards consideration, (ii) a significant change in the types or a significant increase in the amounts of any effluent that may be released offsite, or (iii) a significant increase in individual or cumulative occupational radiation exposure.

Serial No.16-263 Docket Nos. 50-280/281 Page 21 of 22 Accordingly, the proposed change meets the eligibility criterion for categorical exclusion set forth in 10 CFR 51.22(c)(9).

Therefore, pursuant to 10 CFR 51.22(b), no environmental impact statement or environmental assessment need be prepared in connection with the proposed change.

7.0 CONCLUSION The proposed revision extends the TS 3.14.B AOT for one inoperable ESW pump from 7 to 14 days for the specified plant operating conditions (i.e., both units operating or one operating and one in cold shutdown with specified heat loads). The design function of the ESW pumps is to ensure that water can be provided to the intake canal (i.e., the ultimate heat sink) when power is not available to the CW pumps.

The proposed extension of the AOT for one inoperable ESW pump from 7 to 14 days does not impact the design function of the ESW pumps and does not impact the number of ESW pumps required to be operable for the specified plant operating conditions. Additionally, the proposed change does not physically alter plant equipment, does not impact plant operation, and does not affect the safety analyses.

A supporting PRA was performed for the proposed AOT change. The PRA concluded that the increase in risk associated with the proposed change is consistent with the RG 1.17 4 and RG 1.177 acceptance guidelines for a permanent TS AOT change. This PRA evaluation demonstrates that defense-in-depth will not be significantly impacted by changing the AOT for one inoperable ESW pump from 7 to 14 days. Furthermore, no enhancements, procedure revisions, or compensatory actions are recommended as a result of the RG 1.177 Tier 2 evaluation.

Therefore, Dominion concludes, based on the considerations discussed herein that (1) there is reasonable assurance that the health and safety of the public will not be endangered by operation in the proposed manner, (2) such activities will be conducted in compliance with the Commission's regulations, and (3) the issuance of the amendment will not be inimical to the common defense and security or to the health and safety of the public.

105 Unit 1 RSHXS 104 Unit 1 BCHXS 103 B&C A

B c

CCHXS (Ccmmoo)

Disct>.arge Canal r:~;~~:-J

_________ l i MER 4-*-- -------1 1n*

i I

___
, ::. __ :f __ :c:: _____ _J TBSW i~R~j L0 L_ ____________ _

RWMUPP Intake canal 205 Unit2 RSHXS 2()4 Figure 1 - Circulating Water and Service Water Systems Simplified Diagram B&C Abandoned

_______ /,

CWMOVS:

T I

20s n:

0 0

(")

...... C/J Z

CD

"'U 0

Q>)>~D>

cc ::i:01z CDD>o 0 Ng. N.

N 3 ()) __..

oro!29>

-::J NN N

...... ()) O>

N --" --" W

  • Attachment 2 Serial No.16-263 Docket Nos. 50-280/281 MARKED-UP TECHNICAL SPECIFICATIONS AND BASIS PAGES (Basis Changes are for NRC Information Only)

Virginia Electric and Power Company (Dominion)

Surry Station Units 1 and 2

N 0 G 1-1 A f\\J ~~ 0 ~ IH-Is PA G, E. -

'PR. DV ! D E: u Fu R I r.J ic () RJVI A n 0 l'1 3.14 CIRCULATING AND SERVICE WATER SYSTEMS Applicability Applies to the operational status of the Circulating and Service Water Systems.

Objective TS 3.14-1 09-23-13 To define those limiting conditions of the Circulating and Service Water Systems necessary to assure safe station operation.

Specification A. The Reactor Coolant System temperature or pressure of a reactor unit shall not exceed 350° For 450 psig, respectively, or the reactor shall not be critical unless:

1. The high level intake canal is filled to at least elevation +23.0 feet at the high level intake structure.
2. Unit subsystems, including piping and valves, shall be operable to the extent of being able to establish the following:
a. Flow to and from one bearing cooling water heat exchanger.
b. Flow to and from the component cooling heat exchangers required by Specification 3.13.(*)
3. At least two circulating water pumps are operating or are operable.
4. Three emergency service water pumps are operable; these pumps will service both units simultaneously.

(*) For the purpose of cleaning, performing inspections, repairing (as needed), and recoating (as needed) associated with the Service Water (SW) supply piping to the Component Cooling Heat Exchangers (CCHXs), a temporary 30" safety-related, seismic, not fully missile protected supply line (temporary jumper) will be provided to supply SW flow to the CCHXs required by TS 3.13. The basis for using the temporary jumper is provided in Virginia Electric and Power Company's letter Serial No.12-615, dated September 26, 2012. The use of the temporary jumper is permitted two times only for a duration of up to 35 days during each of the 2013 and 2015 Unit 1 refueling outages. If non-essential SW isolation is required during the pipe maintenance activities, it will be accomplished consistent with design basis requirements by using operator (manual) action to close the SW isolation valve in the temporary jumper within the time constraints established by the Station Abnormal Procedures. If the temporary jumper becomes inoperable during either 35-day period, the requirements of Specification 3.0.1 shall apply. Upon completion of the work associated with the second 35-day period, this footnote will no longer be applicable.

Amendment Nos. 279 and 279

TS 3.14-2

_Q4-Q;;ae9-

5. Two service water flow paths to the charging pump service water subsystem are OPERABLE.
6. Two service water flow paths to the recirculation spray subsystems are OPERABLE.
7. Two service water flow paths to the main control room and emergency switchgear room air conditioning subsystems are OPERABLE.

/4 B. The requirements of Specification 3.14.A.4 may be modified to allow on/Emergency Service Water pump to remain inoperable for a period not to exceed.Jdays. If this pump is not OPERABLE in ¥ays, then place both units in HOT SHUTDOWN within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and CO~D SHUTDOWN within the next 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

14 14 The requirements of 3.14~A.4 may be modified to have two Emergency Service Water pumps OPERABLE with one unit in COLD SHUTDOWN with combined Spent Fuel pit and shutdown unit decay heat loads of 25 million BTU/HR or less.

One of the two remaining pumps may be inoperable for a period not to exceed

..:;7-days. If this pump is not OPERABLE in "}days, then place the operating unit in HOT SHUTDOWN within the next 6 hour6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />( and COLD SHUTDOWN within the next 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

J C. The requirements of Specifications 3.14.A.5, 3.14.A.6, and 3.14.A.7 may be modified to allow unit operation with only one OPERABLE flow path to the charging pump service water subsystem, the recirculation spray subsystems, and to the main control and emergency switchgear rooms air conditioning condensers. If the affected systems are not restored to the requirements of Specifications 3.14.A.5, 3.14.A.6, and 3.14.A.7. )"'

within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />, Amendment Nos.~~

Basis TS 3.14-3

~~9-the reactor shall be placed in HOT SHUTDOWN. If the requirements of Specifications 3.14.A.5, 3.14.A.6, and 3.14.A.7 are not met within an additional _)/

48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br />, the reactor shall be placed in COLD SHUTDOWN.

The Circulating and Service Water Systems are designed for the removal of heat resulting from the operation of various systems and components of either or both of the units.

Untreated water, supplied from the James River and stored in the high level intake canal is circulated by gravity through the recirculation spray coolers and the bearing cooling water heat exchangers and to the charging pumps lubricating oil cooler service water pumps which supply service water to the charging pump lube oil coolers.

In addition, the Circulating and Service Water Systems supply cooling water to the component cooling water heat exchangers and to the main control and emergency switchgear rooms air conditioning condensers. The Component Cooling heat exchangers are used during normal plant operations to cool various station components and when in shutdown to remove residual heat from the reactor. Component Cooling is not required on the accident unit during a loss-of-coolant accident. If the loss-of-coolant accident is coincident with a loss of off-site power, the nonaccident unit will be maintained at HOT SHUTDOWN with the ability to reach COLD SHUTDOWN.

The long term Service Water requirement for a loss-of-coolant accident in one unit with simultaneous loss-of-station power and the second unit being brought to HOT SHUTDOWN is greater than 15,000 gpm. Additional Service Water is necessary to bring the nonaccident unit to COLD SHUTDOWN. Three diesel driven Emergency Service Water pumps with a design capacity of 15,000 gpm each, are provided to supply water to the High Level Intake canal during a loss-of-station power incident. Thus, considering the single active failure of one pump, tlfree Emergency Service Water pumps are required to be OPERABLE. The allowed outage time of +.fays provides operational flexibility to

~

allow for repairs up to and (L}-

Amendment Nos. *~...z.5-i-

No cHA~G,E.

Po<.uv 1 Dt::b TH IS PA6>£-

J t-JF="o1'<.MAT 100 Ts 3.14-4 09-23-13 including replacement of an Emergency Service Water pump without forcing dual unit outages, yet limits the amount of operating time without the specified number of pumps.

When one Unit is in Cold Shutdown and the heat load from the shutdown unit and spent fuel pool drops to less than 25 million BTU/HR, then one Emergency Service Water pump may be removed from service for the subsequent time that the unit remains in Cold Shutdown due to the reduced residual heat removal and hence component cooling requirements.

A minimum level of + 17.2 feet in the High Level Intake canal is required to provide design flow of Service Water through the Recirculation Spray heat exchangers during a loss-of-coolant accident for the first 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. If the water level falls below +23' 6",

signals are generated to trip both unit's turbines and to close the nonessential Circulating and Service Water valves. A High Level Intake canal level of +23' 6" ensures actuation prior to canal level falling to elevation +23'. The Circulating Water and Service Water isolation valves which are required to close to conserve Intake Canal inventory are periodically verified to limit total leakage flow out of the Intake Canal. In addition, passive vacuum breakers are installed on the Circulating Water pump discharge lines to assure that a reverse siphon is not continued for canal levels less than +23 feet when Circulating Water pumps are de-energized. The remaining six feet of canal level is provided coincident with ESW pump operation as the required source of Service Water for heat loads following the Design Basis Accident.

To facilitate cleaning, inspecting, repairing (as needed), and recoating (as needed) of the Service Water (SW) supply line to the Component Cooling Heat Exchangers (CCHXs), a temporary, safety-related, seismic, not fully missile protected SW supply line (temporary jumper) will be used as discussed in the temporary footnote to TS 3.14.A.2.b. The temporary jumper is required since service water is supplied to the CCHXs by a single concrete-encased line. To remove the SW supply line from service for extended maintenance (i.e., for pipe cleaning, inspection, repair, and recoating), an alternate temporary SW supply path is required to support the operation of the CCHXs during the maintenance activities. The basis for using the temporary SW supply jumper to the CCHXs is provided in Virginia Electric and Power Company's letter Serial No.12-615, dated September 26, 2012. The use of the temporary jumper is only permitted for a duration of up to 35 days during each of the 2013 and 2015 Unit 1 refueling outages and shall be operated in accordance with the compensatory measures (including a Contingency Action Plan) provided in the letter referenced above. The only automatic function in the normal supply line when Unit 1 is in COLD SHUTDOWN or REFUELING SHUTDOWN is Amendment Nos. 279 and 279 Serial No.16-263 Docket Nos. 50-280/281 PROPOSED TECHNICAL SPECIFICATIONS AND BASIS PAGES.

(Basis Changes are for NRC Information Only)

Virginia Electric and Power Company (Dominion)

Surry Station Units 1 and 2

TS 3.14-2

5. Two service water flow paths to the charging pump service water subsystem are OPERABLE.
6. Two service water flow paths to the recirculation spray subsystems are OPERABLE.
7. Two service water flow paths to the main control room and emergency switchgear room air conditioning subsystems are OPERABLE.

B. The requirements of Specification 3.14.A.4 may be modified to allow one Emergency Service Water pump to remain inoperable for a period not to exceed 14 days. If this pump is not OPERABLE in 14 days, then place both units in HOT SHUTDOWN within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and COLD SHUTDOWN within the next 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

The requirements of 3.14.A.4 may be modified to have two Emergency Service Water pumps OPERABLE with one unit in COLD SHUTDOWN with combined Spent Fuel pit and shutdown unit decay heat loads of 25 million BTU/HR or less.

One of the two remaining pumps may be inoperable for a period not to exceed 14 days. If this pump is not OPERABLE in 14 days, then place the operating unit in HOT SHUTDOWN within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and COLD SHUTDOWN within the next 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

C. The requirements of Specifications 3.14.A.5, 3.14.A.6, and 3.14.A. 7 may be modified to allow unit operation with only one OPERABLE flow path to the charging pump service water subsystem, the recirculation spray subsystems, and to the main control and emergency switchgear rooms air conditioning condensers. If the affected systems are not restored to the requirements of Specifications 3.14.A.5, 3.14.A.6, and 3.14.A.7 within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />, Amendment Nos.

Basis TS 3.14-3 the reactor shall be placed in HOT SHUTDOWN. If the requirements of Specifications 3.14.A.5, 3.14.A.6, and 3.14.A.7 are not met within an additional 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br />, the reactor shall be placed in COLD SHUTDOWN.

The Circulating and Service Water Systems are designed for the removal of heat resulting from the operation of various systems and components of either or both of the units.

Untreated wa.ter, supplied from the James River and stored in the high level intake canal is circulated by gravity through the recirculation spray coolers and the beariµg cooling water heat exchangers and to the charging pumps lubricating oil cooler service water pumps which supply service water to the charging pump lube oil coolers.

In addition, the Circulating and Service Water Systems supply cooling water to the component cooling water heat exchangers and to the main control and emergency switchgear rooms air conditioning condensers. The Component Cooling heat exchangers are used during normal plant operations to cool various station components and when in shutdown to remove residual heat from the reactor. Component Cooling is not required on the accident unit during a loss-of-coolant accident. If the loss-of-coolant accident is coincident with a loss of off-site power, the nonaccident unit will be maintained at HOT SHUTDOWN with the ability to reach COLD SHUTDOWN.

The long term Service Water requirement for a loss-of-coolant accident in one unit with simultaneous loss-of-station power and the second unit being brought to HOT SHUTDOWN is greater than 15,000 gpm. Additional Service Water is necessary to bring the nonaccident unit to COLD SHUTDOWN. Three diesel driven Emergency Service Water pumps with a design capacity of 15,000 gpm each, are provided to supply water to the High Level Intake canal during a loss-of-station power incident. Thus, considering the single active failure of one pump, three Emergency Service Water pumps are required to be OPERABLE. The allowed outage time of 14 days provides operational flexibility to allow for repairs up to and Amendment Nos.

Serial No.16-263 Docket Nos. 50-280/281 TECHNICAL ADEQUACY OF THE PROBABILISTIC RISK ASSESSMENT MODEL Virginia Electric and Power Company (Dominion)

Surry Station Units 1 and 2

TECHNICAL ADEQUACY OF THE PROBABILISTIC RISK ASSESSMENT (PRAl MODEL Serial No.16-263 Docket Nos. 50-280/281 Page 1*of41 The PRA model used to analyze the risk of the Emergency Service Water (ESW) pump allowed outage time (AOT) extension from 7 to 14 days is referred to as S007Aa. The effective date of this model is September 30, 2009. Surry PRA Model Notebook QU.2, Rev.5 documents the quantification of the PRA model. This is the most recent evaluation of the SPS internal events at-power risk profile. The PRA model is maintained and updated under a PRA configuration control program in accordance with Dominion procedures. Plant changes, including physical and procedural modifications and changes in performance data, are reviewed and the PRA model is updated to reflect such changes periodically by qualified personnel, with independent reviews and approvals.

Summary of the Surry Power Station (SPS) PRA History The Level 1 and Level 2 Surry Power Station SPS PRA analyses were originally developed and submitted to the Nuclear Regulatory Commission (NRC) in 1991 as the Individual Plant Examination (IPE) submittal. The SPS PRA has been updated many times, since the original IPE. A summary of the SPS PRA history is as follows:

Original IPE (August 1991)

Individual Plant Examination External Events (IPEEE) 1991 through 1994 1998 - Data update; update to address issues needed to support the Maintenance Rule program 2001 - Data update; update to address more Maintenance Rule issues, address peer review Facts and Observations (F&Os) 2002 - Update RCP seal LOCA model due to installation of high temperature a-rings; added internal flooding, additional changes for Maintenance Rule and Safety Monitor 2004 - Update to address applicable F&Os from North Anna peer review 2005 - Update to include plant changes to reduce turbine building flood risk 2006 - Data update and update to address MSPI requirements 2006 - Update to support ESGR chilled water Tech Spec change; added loss of main control room HVAC and loss of instrument air to the model; added logic from the IPEEE fire and seismic models

Serial No.16-263 Docket Nos. 50-280/281 Page 2 of 41 2009 - Data update; addressed American Society of Mechanical Engineers (ASME) PRA Standard SRs that were not met; extensive changes throughout the model as the model was converted to CAFTA 2009 - Updated Interfacing Systems LOCA (ISLOCA) initiator frequency, added EDG and AAC diesel fails to load (FTL) basic events, and added rupture failure of the SW expansion joints for the CCW heat exchangers as flood scenarios (current model of record)

The SPS PRA model has benefited from the following technical PRA peer reviews.

1998 NEI PRA Peer Review The SPS internal events PRA received a formal industry PRA model peer review in 1998. The purpose of the PRA peer review process is to provide a method for establishing the technical quality of a PRA model for the spectrum of potential risk-informed plant licensing applications for which the PRA model may be used. The PRA peer review process used a team composed of industry PRA and system analysts, each with significant expertise in both PRA model development and PRA applications. This team provided both an objective review of the PRA technical elements and a subjective assessment, based on their PRA experience, regarding the acceptability of the PRA elements. The team used a set of checklists as a framework within which to evaluate the scope, comprehensiveness, completeness, and fidelity of the PRA products available.

The SPS review team used the 'Westinghouse Owner's Group (WOG) Peer Review Process Guidance" as the basis for the review.

The general scope of the PRA peer review included a review of eleven main technical elements, using checklist tables (to cover the elements and sub-elements), for an at-power PRA including internal events, internal flooding, and containment performance, with focus on Large Early Release Frequency (LERF).

The F&Os from the PRA peer review were prioritized into four categories (A through D) based upon importance to the completeness of the model. Categories A and B F&Os are considered significant enough that the technical adequacy of the model may be impacted. Categories C and D are considered minor. Subsequent to the peer review, the model has been updated to address all Category A, B, and D F&Os. Category B items from the 1998 NEI PRA Peer Review (all closed) are listed below:

OBSERVATION OBSERVATION (ID: AS-2

)

I ElementAS I Subelement 5 and 9 (Also MU)

OBSERVATION (ID: AS-8

)

I Element

_AS -- I Subelement

_AS-12 __

Serial No.16-263 Docket Nos. 50-280/281 Page 3 of 41 1998 NEI PRA Peer Review Category 8 Closed Items OBSERVATION DETAIL LEVEL OF POSSIBLE RESOLUTION PLANT RESPONSE OR RESOLUTION STATUS SIGNIFICANCE The models and analyses are consistent, B (It is important that Establish a formal process for PRA update guidance was developed, which This F&Ois as best as the reviewers could determine, the PRA model an identifying changes to plant includes a review of plant procedures CLOSED.

with the as built plant, and were consistent appropriately current procedures (EOPs/AOPs), and (EOPs), assumptions for components, and with plant operating procedures at the time plant configuration, evaluating the impact of these system recovery models based upon human the IPE was completed. However, there is and that there is a changes on the PRA model. This actions (Nuclear Safety Analysis Manual -

no process in place to identify and process for process should also include Part IV, Chapter J, subsequently superceded incorporate changes in plant operation into determining how and periodic review of industry by PRA Manual - Part IV, Chapter A). The the PRA model. This process should also when plant changes standards that may affect current industry guidance suggests a include periodic review of industry should be modeling assumptions and voluntary periodic review of industry standards that may impact the PRA. Some incorporated into the success criteria used in the PRA.

standards, which will be considered as examples of where such a process could PRA models.

The resolution of this comment resources allow. Recent PRA updates impact the model include, the timing for However, this should be incorporated as an (S03A, SOSA) provide examples of the switchover to hot leg recirculation after observation is not a element of the PRA Maintenance process.

event initiation (9 hours1.041667e-4 days <br />0.0025 hours <br />1.488095e-5 weeks <br />3.4245e-6 months <br /> in the current EOP),

contingent item and Update Process.

and a review of potential impacts on the within the review of PRA due to the power uprate program. The PRA technical focus of this comment is on the lack of element AS, since it process more than any current is more generically discrepancies found in the model, and is addressed within the related to the IPE Maintenance and Update review for element Process elements.

MU.)

The RCP seal LOCA model appears to B (The treatment of Consider an evaluation of the An RC pump seal failure model (the so-The PRA adequately include an optimistic interpretation of the RCP seal LOCA has sensitivity of the PRA results to called Rhodes model) that is acceptable to addresses early seal WOG and NRC models, and does not the potential to use of a model that includes the the NRC for use in PRA was developed and failure contribution, include a contribution from early seal significantly affect possibility of early seal failure.

implemented for the T4, T1A and T6 event so this F&O is failure.

PRA results, and Alsci evaluate the potential impact trees. This model addresses the probability CLOSED. Future could therefore be on the model due to recent of early seal failure, and does not allow model updates are considered to have a changes to the WOG seal cooling restoration of seal cooling after a relatively planned to include greater significance restoration emergency response brief cooling loss. For Surry, the model is additional model level. Although guidelines (advising against discussed fully in SM-1296, implemented in detail (and remove there is currently no restoration of seal cooling after a the SOA-D PRA models. For the S03A conservatisms) for standard modeling relatively brief cooling loss).

model, the T1A (SBO) accident sequence the seal failure approach, the model was revised to be fully consistent with contribution for assumptions used the WOG2000 RCP seal LOCA model, and events other than for the Surry model the T4 and T6 accident sequences models T1A.

appear to be were revised to incorporate simplified logic optimistic relative to consistent with the WOG2000 model.

assumptions used for other PRAs.)

OBSERVATION OBSERVATION DETAIL LEVEL OF SIGNIFICANCE The models for the EDGs do include B

OBSERVATION common cause failures of fuel oil system.

(ID: DA-6 )

I In general the models do consider Element common/shared components and support

_QA_ I systems explicitly. The models do not Subelement appear to include the effects of common DA-11 maintenance crews or l&C technicians.

Specifically, there is no consideration of common cause miscalibration of instrumentation channels.

(Implementation of NUREG/CR-4780 B

OBSERVATION methodology) Reviewers question the (ID: DA-8

)

I validity of the approach used for defining Element CCF terms, by adding fail to start and fail to DA/DE I

run data variables. Method added value of Subelement QD and f.., but the events are not consistent DA-12/DE-9 (i.e. per-demand and per-hour). Assuming a mission time of one hour and a demand for the device, the terms can be added. But what if: 1. Common cause failure is dominated by running failures, there is no mission time associated with the use of the common cause term - non-conservative result 2. Running failure rate is comparable to start term, but common cause dominated by start terms - overly conservative result.

POSSIBLE RESOLUTION

  • Update the models to include common cause instrumentation miscalibration. Documentation should at least include a qualitative discussion of the potential impact of common maintenance crews and similar procedures. The documentation should also highlight areas where common cause fault (CCF) was not included because of design diversity or other similar considerations.

Reevaluate CCF analysis as described in Surry guidance documents. Fully incorporate NUREG/CR-4780 methods.

Serial No.16-263 Docket Nos. 50-280/281 Page 4 of 41 PLANT RESPONSE OR RESOLUTION STATUS Miscalibration of instrumentation channels is This F&Ois resolved as a human reliability rather than an CLOSED.

equipment common cause fault. The HEP fault behaves the same as an equipment CCF, but is quantified on the basis of human error rather than equipment reliability. For North Anna, HEP events are created for the following instrument channels: EOG, 1-LM-PT-100A/B/C/D, MS flow, MS differential pressure, MS low pressure, and pressurizer pressure. The models are discussed fully in SM-1269, implemented in the NOA-D PRA models. For Surry, HEP events are created for the following instrument channels: EOG, 1-LM-PT-1 OOA/B/C/D, MS flow, MS differential pressure, steam generator level, pressurizer pressure RWST level, intake canal level and RC delta T and TAVE. The models are discussed fully in SM-1310, implemented in the SOA-D PRA models.

The CCF approach is revised to incorporate ThisF&Ois the following: Alpha-factor model, !NEEL CLOSED.

data base of CCF events from NUREG/CR-6268, different failure modes (run and demand), and different CCF events based upon population size (e.g., 2 of 3 as well as 3 of 3 CCF events. Guidance for the CCF models was taken from NUREG/CR-5485, which extends the technology developed for NUREG/CR-4780. The models are discussed fully in SM-1309, implemented in the SOA-D PRA models for Surry, and in the DA.3 notebook and revisions prepared for subsequent model updates (starting with S03A).

OBSERVATION OBSERVATION DETAIL The CCF probability of valves failing due to OBSERVATION plugging is (0.1)(1.25-7 f/hr)(2160 hrs), or (ID: DA-9 )

I about 1 E-4. The 0.1 beta factor used for Element this calculation may be overly conservative.

___QA_ I The net result is that many of the top Subelement sequences (for the 3-year maintenance

_9_

case) involve common cause valve plugging terms. It is unusual to have passive equipment failures be so prominent in the dominant cutsets (more prominent than active equipment failures).

The methods used to determine CCF OBSERVATION groups are simplistic. Determination of the (ID: DE-3

)

set of active components based on 1 %

I Element contribution to GDF severely limits the

_DE_ I number and type of common cause terms Subelement used in the model. As an evaluation tool for

_s __

plant vulnerabilities (i.e., the IPE), it is more than sufficient, but as an evaluation tool for Risk-informed Applications, it is not enough.

Events that should be considered include:

Breaker fail to operate (Open/Close),

Auxiliary Feedwater Pumps (back-leakage),

Ventilation fans.

LEVEL OF POSSIBLE RESOLUTION SIGNIFICANCE B (The over Consider the use of a more conservatism in the realistic beta factor in the beta factor could analysis.

cause erroneous conclusions when the PRA results are used for ranking applications, such as Maintenance Rule or valve programs (MOV, AOV, CV).)

B (A careful The generic data base consideration of development project identifies a common cause large number of common-cause modeling groups. Incorporate these requirements is groups or better justify their important for PRAs exclusion.

used for risk-informed applications.)

Serial No.16-263 Docket Nos. 50-280/281 Page 5 of 41 PLANT RESPONSE OR RESOLUTION STATUS The CCF approach is revised to incorporate ThisF&Ois the following: Alpha-factor model, INEEL CLOSED.

data base of CCF events from NUREG/CR-6268, different failure modes (run and demand), and different CCF events based upon population size (e.g., 2 of 3 as well as 3 of 3 CCF events. Guidance for the CCF models was taken from NUREG/CR-5485, which extends the technology developed for NUREG/CR-4780. The models are discussed fully in SM-1309, implemented in the SOA-D PRA models for Surry, and in the DA.3 notebook and revisions prepared for subsequent model updates (starting with S03A).

The CCF approach was revised to ThisF&Ois incorporate the following: Alpha-factor CLOSED.

model, INEEL data base of CCF events from NUREG/CR-6268, different failure modes (run and demand), and different CCF events based upon population size (e.g., 2 of 3 as well as 3 of 3 CCF events. Guidance for the CCF models was taken from NUREG/CR-5485, which extends the technology developed for NUREG/CR-4780. The models are discussed fully in SM-1309, implemented in the SOA-D PRA models for Surry, and in the DA.3 notebook and revisions prepared for subsequent model updates (startinc:i with S03A).

OBSERVATION OBSERVATION DETAIL LEVEL OF SIGNIFICANCE Table D.1-1 of Section D.1 of the Surry IPE B (The lack of OBSERVATION lists the pre-initiator errors considered in the miscalibration His (ID: HR-2)

I analysis. The list contains only could be significant.

Element mispositioning events (valves, blank The actual effect is HR/DE/SY I

flanges, etc.). No instrument miscalibration not known.)

Subelements events are contained in the list. The HR-417/DE-7/SY-procedure for system analysis (page 19 of

.!L

58) indicates that common cause His should be modeled for miscalibration of instruments used to initiate systems following an action or in any standby equipment items such as the level instrumentation in storage tanks.

HEP development for the IPE model was B (HEPs can have a OBSERVATION extensively documented; however, HEPs significant effect on (ID: HR-4 )

I developed for subsequent updates of the model results. HEPs Element IPE model were not as well documented added to the model

--1:!.R...._ I (and by implication, were not developed in as the result of Subelement as much detail). For many of the HEPs in updates should be

~

subsequent updates, a value of 0.1 was developed and used. It is not clear whether this is a documented to the screening value or some other value.

same level as the IPE HEPs.)

POSSIBLE RESOLUTION Provide the basis for excluding miscalibration events, or develop appropriate events for inclusion in the next update of the PRA model.

Perform and document development of HEPs that arise from model updates.

Serial No.16-263 Docket Nos. 50-280/281 Page 6 of 41 PLANT RESPONSE OR RESOLUTION STATUS Miscalibration of instrumentation channels is This F&Ois resolved as a human reliability rather than an CLOSED.

equipment common cause fault. The HEP fault behaves the same as an equipment CCF, but is quantified on the basis of human error rather than equipment reliability. For North Anna, HEP events are created for the following instrument channels: EOG, 1-LM-PT-100NB/C/D, MS flow, MS differential pressure, MS low pressure, and pressurizer pressure. The models are discussed fully in SM-1269, implemented in the NOA-D PRA models. For Surry, HEP events are created for the following instrument channels: EOG, 1-LM-PT-100NB/C/D, MS flow, MS differential pressure, steam generator level, pressurizer pressure RWST level, intake canal level and RC delta T and TAVE. The models are discussed fully in SM-1310, implemented in the SOA-D PRA models.

The HEP events developed since the IPE ThisF&Ois have received detailed analysis. For North CLOSED.

Anna, the models are discussed fully in SM-1269, implemented in the NOA-D PRA models. For Surry, the models are discussed fully in SM-1310, implemented in the SOA-D PRA models, and in the HR-series notebooks developed for the S03A and subsequent updates. This process was also reviewed as part of the HRA re-peer review exercise prior to the RG1.200 review for Surrv.

OBSERVATION OBSERVATION DETAIL OBSERVATION In a sensitivity analysis (SM-1174, (ID: HR-5 )

I Addendum A) to evaluate dependency Element among His contained in cutsets, time

___!:ilL I between actions was listed as the major Subelement factor in establishing independence of the

___.lL operator actions. In most cases, time (itself) is not an adequate factor, but is a parameter which.can be associated with more defensible factors. For example, one cutset contained two HEPs - one for early SG isolation following a SGTR and one for late SG isolation. The time difference of several hours between the actions was cited as the basis for the actions' independence. Better factors for independence might have been different clues calling for the need to isolate the SG

. or actuation of the TSC, or additional/new crew for the late isolation. All of these are related to time, but time (itself) is not the factor.

Initiating event frequencies have not been OBSERVATION updated since the IPE submittal in 1991.

(ID: IE-3 )

I As a result, recent industry information and Element IE operating experience have not been I Subelement incorporated into the initiating events

__ll.__ (Also analysis. This information could alter t.he MU) initiating event frequencies currently contained in the model. For example: Two plants (Salem and Wolf Creek) have experienced losses of circulating and service water that resulted in plant trips.*

One plant (Oconee) has experienced a small break LOCA (thermal fatigue of charging line). *One plant (WNP-2) has experienced an internal flood.* A draft NUREG updating initiating events has (very recently) been issued (LOCA frequencies, particularly, have been affected).

LEVEL OF POSSIBLE RESOLUTION SIGNIFICANCE B (Reevaluating Reevaluate dependence without dependence among excessive emphasis on time HEPs focusing on between actions.

factors other than time could produce different conclusions about dependency.

The effect of a reevaluation on analysis results is not known.)

B (Application Include an. update of initiating results may be event frequencies during the next affected by inclusion update. Also, individual of the new applications should be reviewed information.)

to determine if they are affected before submittal or implementation.

Serial No.16-263 Docket Nos. 50-280/281 Page 7 of 41 PLANT RESPONSE OR RESOLUTION STATUS The dependency among the HEPs is being ThisF&Ois evaluated based on the following principles CLOSED.

(SM-1310): 1.

Functions: If two HEPs are working for two different functions, these two HEPs will be justified as independent HEPs.

2.

Steps of procedure: Because operators are trained to follow procedure step by step, on the view of operators, each step is a new and independent instruction. If two HEPs are based on two different steps or two different procedures, even these two HEPs work for the same function, they still may be justified as independent HEPs. A sensitivity analysis was performed for the S03A model update (and has been incorporated into the PRA quantification process for subsequent updates) to review the cutsets with multiple HEPs and determine if a dependency may exist between the HEPs. Referto the PRA QU.2 notebooks for further detail. This process was also reviewed as part of the HRA re-peer review exercise prior to the RG1.200 review for Surrv.

The North Anna and Surry initiating event ThisF&Ois frequencies were updated in the NOA-D and CLOSED.

SOA-D PRA updates by several sources.

The rare initiator frequencies from NUREG/CR-5750 are used as priors for Bayesian updating with plant specific histories. The moderate frequency transient initiating event frequencies are created from plant specific data (1990-2000 lERs) and a non-informative gamma prior distribution.

Finally, some plant unique initiating events are quantified with new fault tree models directly linked to the integrated PRA model.

For North Anna, these models are discussed fully in Calculation SM-1266, implemented in the NOA-D PRA models. For Surry, these models are discussed fully in Calculation SM-1307,. implemented in the SOA-D PRA models. All IE frequencies have subsequently been updated in 2005 and documented in the IE.1 and IE.2 notebooks.

OBSERVATION OBSERVATION DETAIL LEVEL OF SIGNIFICANCE A recent industry event (Oconee) involved a B (If this is a valid OBSERVATION small break LOCA (>10 gpm) at the failure mechanism (ID: IE-4

)

charging line connection to the RCS. The for small break I Element mechanism for the crack in the thermal LOCAs, the effect on

_IE_ I sleeve at the connection point was thermal frequency should be Subelement fatigue. Is the Surry piping subject to this considered in the 7

(Also type of event? If so, has it been considered Surry analysis.)

MU) in the initiating event frequency?

POSSIBLE RESOLUTION Evaluate the susceptibility of the Surry piping to this failure mechanism, and adjust the LOCA frequencies, as appropriate.

Serial No.16-263 Docket Nos. 50-280/281 Page 8 of 41 PLANT RESPONSE OR RESOLUTION STATUS The referenced Oconee event was evaluated ThisF&Ois as part of INPO SEN 163, Recurring Event, CLOSED.

High Pressure Injection Line Leak, and as part of NRC IN 97-46, Unisolable Crack in High-Pressure Injection Piping. The design of the CVCS and HHSI systems at both North Anna and Surry is significantly different than that of Oconee, Unit 2. NAPS and SPS designs do not include combination eves makeup and HHSI lines. Each unit has only one eves makeup line which carries full makeup flow and the eves system employs a regenerative heat exchanger to heat the makeup water to within 100 degrees of the RCS cold leg temperature, thereby minimizing thermal shock. The Oconee failure mechanism is not considered valid for the North Anna or Surry designs, and should not require LOCA frequency adjustment.

The Current North Anna and Surry LOCA frequencies are developed from NUREG/CR-5750, per the evaluation in the IE.2 PRA notebook. This NUREG observed that no small LOCA events had occurred in U. S.

nuclear power plants up to 1995. However, the 1997 Oconee 2 event could possibly be categorized as a very small LOCA / leak, and four such events from 1987 - 1995 are included within the NUREG/CR-5750 initiatino event freauencies.

OBSERVATION OBSERVATION DETAIL LEVEL OF POSSIBLE RESOLUTION SIGNIFICANCE An industry issue of about 5-6 years ago B (The sequence Determine if the ISLOCA path is OBSERVATION was the creation of an ISLOCA caused by a described above, if applicable to the Surry model, (ID:: IE-5

)

leak in an RCP thermal barrier heat applicable, and address it, if appropriate.

I Element exchanger and a failure to isolate the CCW represents an

_IE_ I lines that provided cooling water to the heat ISLOCA path that is Subelement exchanger. How was this potential ISLOCA not addressed by 14 pathway treated by the initiating events the Surry analysis.)

analysis? Does it apply to the Surry model?

Serial No.16-263 Docket Nos. 50-280/281 Page 9 of 41 PLANT RESPONSE OR RESOLUTION STATUS The industry issue initially surfaced in July Additional 1984 as a Westinghouse 10CFR Part 21 information can be issue. However, since Westinghouse was found in a 7/9/1990 not the source vendor for the Surry CC NRC letter (Serial system, this Part 21 issue was not No.90-442), and communicated to Surry at that time. In May drawings 11448-FM-1989, Surry communicated this issue to NRC 072A shts 1 through and subsequently, NRC Information Notice

4. This F&O is 89-54 (June 23, 1989) was issued to all CLOSED.

licensees. This NRC IN is probably the source of the industry issue quoted in the certification comment. Surry submitted system design information to NRC in a June 5, 1989 letter to NRC (Serial No.89-406) clarifying resolution of the concern. This licensee response provides a detailed description of the problem and an assessment of the resolution. In summary:

§ The operating history of Westinghouse RC Pump (RCP) thermal barriers indicates only one minor internal leak in over 12 million hours of operation (8.3 E-8/hr or 7.3 E-4/yr).

§ Catastrophic failure of RCP thermal barrier is not a credible event. Westinghouse calculated the credible leak rate at 7.5 gpm.

This low leak rate is due to high water purity in RC and CC water, conservatism in tube design supporting tube collapse rather that cracking, and low crack propagation due to external forces tending to close crack.

§ The existing 1989 design was sufficient for isolating the RCP thermal barrier leak, but design enhancements were pursued since manual operator action is required for the credible leak (automatic isolation would occur for leak rates higher than 10 gpm).

§ The event would not be classified an interfacing system LOCA (ISLOCA) since the CC system would be isolated from the RCS, and all isolation would occur within the containment. More appropriately, the event would be classified a very small break LOCA (based upon the 7.5 gpm credible leak) with a frequency well below the Surry and North Anna IPE S2 frequency of 2.1 E-2/yr.

OBSERVATION OBSERVATION DETAIL LEVEL OF SIGNIFICANCE The FMEA portion of the Initiating Events B (Not considering OBSERVATION notebook (page 12 of 28) states that screen the potential effect of (ID: IE-8

)

wash pumps do not have to operate during clogged intake I Element an accident. The implication is that screens could result

_IE_ I because of this there is no need to consider in an Subelement the screen wash system further. However, underestimation of

_1_3_

clogged screens can cause plant trips, and the transient this failure mechanism should be initiating frequency, considered in the development of initiating particularly if there event frequencies. Recent industry events are plant specific at Salem and Wolf Creek illustrate a plant's features that could susceptibility to clogged intake screens.

cause the likelihood of clogged screens to be higher than the industry average.)

The reactor core has been upgraded to B (Increases in core OBSERVATION 2586 MWt. Has the effect of this change power can result in (ID: IE-9) I been considered on the moderator significant changes Element __!£_

temperature coefficienUreactivity feedback, in the moderator I Subelement particularly for early in a core's life? Also, temperature 16 (Also has the increased decay heat load been coefficient I reactivity see AS-9, and considered in the success criteria for decay feedback during the MU) heat removal?

early part of a core's life, and can have a significant effect on success criteria requirements for emergency boration and other methods of shutting down the reactor during ATWS events.)

POSSIBLE RESOLUTION Determine the plant's susceptibility to clogged intake screens, and update the initiating event frequency as appropriate.

Ensure that the effects of increased core power have been properly accounted for in the analysis.

Serial No.16-263 Docket Nos. 50-280/281 Page 10 of 41 PLANT RESPONSE OR RESOLUTION STATUS The Surry Loss of Service Water IE is This F&Ois actually an evolution of a loss of circ water CLOSED.

initiator. We do not currently model this with a fault tree, so there is no specific screen clogging contribution identified for this initiator. Currently, the Surry PRA uses a plant specific Bayesian update of generic industry experience for loss of Circulating Water to evaluate the IE-T6 (Loss of Circulating Water) frequency. The plant specific clogged screen failure event is therefore considered, since it is part of the overall industry and plant-specific experience leading to loss of CW. However, an evaluation has been performed for the S03A model update to establish that the IE frequency used for this event would encompass contributions from events such as clogged intake screens I screen wash faults. Should the model be changed in the future to model this IE with a fault tree, this failure mechanism would be addressed exolicitlv.

The effect of the 4.5% core power uprate on ThisF&Ois the timing of HEPs used in the SPS PRA CLOSED.

Model, and on the success criteria of hardware credited in the SPS PRA Model has been evaluated using MAAP 4.0.5. The results of the analysis show that no changes are required to the current success criteria or HEP calculations. The details of the analysis are documented in SPS Notebook SPS-RA.MD.SC.001 Rev 0.

OBSERVATION OBSERVATION DETAIL The consequences of operator actions after OBSERVATION core damage are not considered in the PRA (JD: L2-2

)

or the LERF assessment. After core I Element damage has occurred, the control room

- L2 __ I staff will continue to attempt to implement Subelement EOP actions (and now SAMG actions).

Band10_

Considering the EOP actions, only those that prevent core damage (have an impact on the CDF) are modeled in the Level 1 PRA. Several EOP actions that can impact the LERF are: 1) FR-C.1 actions to depressurize the RCS at the onset of core overheating greatly decreases the probability of a high pressure reactor vessel failure, while significantly increasing: a) the potential for core concrete interactions, and b) the fission product release from RCS to containment (which, in turn, increases the source term for containment failures).

2) FR-H.1 actions to establish some type of feedwater flow to the SGs increases the chances of SG tube failure due to thermal stresses of cold water being injected onto hot SG tubes, but can also increase the potential for arresting the core damage in-vessel. These two aspects can impact the LERF. 3) ECA-0.0 actions to start sprays when offsite power is restored. This can prevent overpressure failure of containment, but can also de-inert containment and lead to a hydrogen burn.

When combined with the added hydrogen from in-vessel recovery, the hydrogen burn may challenge containment. Also, these operator actions should be substantiated by an HRA analysis to determine the HEP.

The plant has also completed implementation of the SAMG. The SAMG contains a set of accident management strategies that would be implemented for each of the core damage accidents. The implementation of some of the strategies has negative consequences that should be addressed.

LEVEL OF POSSIBLE RESOLUTION SIGNIFICANCE B

Include appropriate consideration of EOP (and also SAMG) actions in the PRA models Serial No.16-263 Docket Nos. 50-280/281 Page 11 of 41 PLANT RESPONSE OR RESOLUTION STATUS Our Level I model takes into account all The approach taken human error probabilities due to EOP is consistent with actions. The human error probabilities based that applied in other on SAMG actions are not incorporated into PWR PRAs, but this our model. According to WOG procedures, issue will be treated once the core temperature reaches 1200 F, as a recognized the operator leaves the EOPs and enters the source of uncertainty SAMGs (control room guideline SACRG-1).

in the LERF model.

Our Level I model was developed With this action, this independent of the SAMG actions. We F&O is CLOSED.

recognize that inappropriate SAMG actions may cause negative consequences which may result in greater source term releases to the atmosphere. For this reason a technical support center (TSC) is formed that reviews real time plant parameter data and provides expert guidance to the operation staff during a severe accident condition. Additionally training on the SAMGs is provided every 3 years which includes a discussion of these cautions and recommendations to the operators. The operators are taught to be aware of their plants most dominant accident sequences and the consequences of inadequate actions.

OBSERVATION OBSERVATION (ID: MU-2 )

I Element __MY__

I Subelement

_4_

OBSERVATION (JD: MU-3 )

I Element_

M!!...._ I Subelement

_4_

OBSERVATION (JD: MU-4 )

I Element __MY__

I Subelement

__§__

OBSERVATION DETAIL The core power has been upgraded.

Effects of this change have not been incorporated into the PRA model. Factors that could be affected by the core power upgrade include the moderator temperature coefficient (for ATWS) and the decay heat load (for several accident seauences).

Requirements for review of operating experience, plant procedures, and plant-controlled documents in support of a PRA update are not detailed in the PRA guidance documents.

Activities to evaluate the effects on the PRA of changes to equipment failure rates, initiator frequencies, and human error probabilities are minimal.

LEVEL OF SIGNIFICANCE B (Inclusion of the effects of a core power upgrade could have a significant effect on the PRA model and analvsis results.)

B (A comprehensive review of plant experience and changes is essential to help assure that the model update adequately represents current plant configuration.)

B (Data must be kept current to keep the model current.)

POSSIBLE RESOLUTION At the next upgrade, evaluate the effects of the core upgrade and incorporate, as appropriate, into the PRA model.

Develop additional guidance on the review process requirements, describing which data should be reviewed and how the review should be documented.

Revisit initiator frequencies, equipment failure rates, and human error probabilities with each update to determine whether they are still adequately estimated.

Serial No.16-263 Docket Nos. 50-280/281 Page 12 of 41 PLANT RESPONSE OR RESOLUTION See discussion for equivalent F&O IE-09.

PRA update guidance was developed, which includes a review of: (1) Technical Specification revisions, (2) station engineering Design Change lists, (3) station procedures, and (4) operating experience.

(Nuclear Safety Analysis Manual - Part IV, Chapter J, subsequently superceded by PRA Manual - Part IV, Chapter A). Recent PRA updates (S03A, SOSA) provide examples of the orocess.

Both the Surry and North Anna PRA models have been updated to include changes in data. For North Anna and Surry, initiating events were updated as documented in calculations SM-1266 for North Anna and SM-1370 for Surry. Component unavailabilities were updated for both North Anna and Surry as documented in calculations SM-1266 and SM-1308, respectively. The component reliabilities for risk significant pumps and the EDGs were Bayesian updated with plant specific data for Surry as documented in SM-1311. Further, a full data update was performed in 2005 for the MSPI update, as documented in the DA series of PRA notebooks. The HEPs were reviewed and updated as necessary following the PRA self-assessment per RG1.200 and in response to the subsequent HRA re-peer review comments. Input from Operations personnel at Surry was obtained to provide better estimation of the times associated with the performance of emergency procedures. A PRA update process and schedule addressing data updates has been implemented in the PRA Manual.

STATUS This F&Ois CLOSED.

This F&Ois CLOSED.

ThisF&Ois CLOSED.

OBSERVATION OBSERVATION DETAIL LEVEL OF SIGNIFICANCE The program does not appear to have a B (It is important to OBSERVATION formal requirement for incorporating risk-informed (JD: SY-2) I changes based on plant design changes.

applications that the Element_SY_

For example, a later EOP change identifies PRA models reflect I Subelement the time to hot leg recirculation switchover recent changes to

_5_(See also as 9 hours1.041667e-4 days <br />0.0025 hours <br />1.488095e-5 weeks <br />3.4245e-6 months <br />. The model says 16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br />.

the plant.)

AS-5, and MU)

There is an advantage to identifying operator actions to specific procedure steps. The downside is, procedures change. Thus, the models and documentation need to be updated periodically.

POSSIBLE RESOLUTION The following suggestions, while directed to the systems analysis element, are actually applicable more broadly, within the context of the overall PRA Maintenance and Update process. 1) Develop a PRA change program that tracks identified changes to procedures, design, etc. Develop a process for incorporating changes into the PRA. NOTE:

This does necessarily mean formal review required; notification from the program sponsor (Procedures group, admin, design engineering, etc.)

is sufficient for most changes.

2) Consider becoming part of the review cycle for selected changes (e.g., for risk significant system design changes, PRA review is required). This will probably require a change to plant, engineering procedures. There are going to be changes in plant configuration that could significantly affect the PRA. A formal review by the PRA group for selected changes has the potential for saving money (change should not be made in terms of plant risk), minimizing the effects of the change on the PRA and PRA based programs and possibly identifying alternative changes.

Serial No.16-263 Docket Nos. 50-280/281 Page 13 of 41 PLANT RESPONSE OR RESOLUTION STATUS PRA update guidance was developed, which ThisF&Ois includes a review of: (1) Technical CLOSED.

Specification revisions, (2) station engineering Design Change lists, (3) station procedures, and (4) operating experience.

(Nuclear Safety Analysis Manual - Part IV, Chapter J, subsequently superseded by PRA Manual - Part IV, Chapter A). Recent PRA updates (S03A, SOSA) provide examples of the process.

OBSERVATION OBSERVATION DETAIL The RPS model does not properly identify OBSERVATION the required support systems. RPS logic (ID: SY-4

)

receives power from Class 1 E 125V DC I Element buses 1A and 1 B. Failure of the DC buses

_SY_ I removes power to the RTB shunt trip coils Subelement which limits operator action in the control

- 12 __

room if reactor trip fails.

The RPS logic model is incorrect. The fault OBSERVATION tree indicates that success of either logic (ID: SY-5

)

train allows challenge to both reactor trip I Element breakers. Actual design is logic train A

_SY_ I sends signal to RTA and logic train B sends Subelement signal to RTB.

_5 __

LEVEL OF POSSIBLE RESOLUTION SIGNIFICANCE B (Support system Review the RPS system and dependencies must include DC power dependency.

be appropriately accounted for in the models.)

B (System models Correct the logic model.

must correctly represent the system function.)

Serial No.16-263 Docket Nos. 50-280/281 Page 14 of 41 PLANT RESPONSE OR RESOLUTION STATUS Fault trees RP1 for both Surry and North This F&Ois Anna were revised to include separate logic CLOSED.

for RTA and RTB including the input logic signal with recovery. The models also include failure of the trip breaker (RTA/RTB),

and RTA/RTB recovery thorough the shunt trip relay (including failure of 125 voe, human reliability model, and failure of the shunt trip relay). The models are discussed fully in SM-1151, implemented in the SOA-D PRA models for Surry, and in SM-1292, implemented in the NOA-D PRA models for North Anna.

Fault trees RP1 for both Surry and North This F&Ois Anna were revised to include separate logic CLOSED.

for RTA and RTB including the input logic signal with recovery. The models also include failure of the trip breaker (RTA/RTB),

and RTA/RTB recovery thorough the shunt trip relay (including failure of 125 voe, human reliability model, and failure of the shunt trip relay). The models are discussed fully in SM-1151, implemented in the SOA-D PRA models for Surry, and in SM-1292, implemented in the NOA-D PRA models for North Anna.

OBSERVATION OBSERVATION DETAIL LEVEL OF SIGNIFICANCE Review of HHSI: SM-1162, SPPR 97-018, B (The PRA models OBSERVATION S2.07.1 (page 7 of 27). System notebook must adequately (ID: SY-11

)

update states 1A and 1C charging pumps reflect recent plant I Element are dependent on CCW (for recirculation).

configuration; unit-

....§Y__ I What about Unit 2? 1 B is not dependent on to-unit differences Subelement CCW due to a design change. What about must be accounted SY-5 Unit 2? How are unit to unit differences for.)

identified and modeled? Dependency table from IPE model wasn't updated in SM-1162 or SM-1165 to account for CCW dependency. Also, success criteria section of system notebook was not updated.

POSSIBLE RESOLUTION Set up Unit 2 model, or address impact on GDF.

Serial No. 16-26~

Docket Nos. 50-280/281 Page 15 of 41 PLANT RESPONSE OR RESOLUTION STATUS Surry charging pumps have seal coolers with ThisF&Ois a CC cooling dependency that currently has CLOSED.

a difference between Units 1 and 2. For Surry Unit 1, the A & C pump seal coolers 1-CH-E-7A/B/E/F require CC cooling, but the B pump seal coolers 1-CH-E-7C/D are isolated (11448-FM-071 B Sh 2). For Surry Unit 2, all A/B/C pump seal coolers 2-CH-E-7A/B/C/D/E/F require CC cooling (11548-FM-071 B Sh 2). Potentially, all Surry charging pumps may be upgraded so that their CHP seal coolers can be isolated, but at this time, only the Surry Unit 1 B pump does not require CC cooling, which explains the difference between Surry Unit 1 and 2 charging pump CC cooling. Update as of SOSA model: the dependency on CC has been added to the 1 B pump as well, to account for the possibility that cooling might be needed if the pumps were used for high head recirculation with hot sump water.

Update as of S007Aa model: This is a legacy model issue. The current configuration of Surry Power Station is that no charging pump seal coolers are normally isolated. The S007Aa model reflects this current plant confiouration.

OBSERVATION OBSERVATION DETAIL LEVEL OF POSSIBLE RESOLUTION SIGNIFICANCE Several HVAC systems are modeled in B (It is important to Develop more detailed OBSERVATION detail and are well documented. These demonstrate that all documentation for modeling (ID: TH-2

)

include ESGR room cooling and the HVAC dependencies assumptions regarding HVAC I ElementTH I Auxiliary Building Ventilation System, but have been requirements. Provide basis for Subelement 8 these are the only ventilation dependencies examined, and that excluding HVAC dependencies modeled in the PRA. Some of the systems assumptions made where HVAC is not modeled models provide a one line assumption in the analyses to explicitly. It may be appropriate stating that room cooling is not required, but determine the need to include an overview of HVAC little if any basis is provided for these for ventilation or issues as part of a dependencies assumptions. Based on discussions with cooling are notebook.

the PRA group engineers during this documented.)

review, it appears that the HVAC requirements were adequately addressed in the modeling process, but the assumptions were not clearly documented, and no process is defined for the determination of the need for room cooling.

Serial No.16-263 Docket Nos. 50-280/281 Page 16 of 41 PLANT RESPONSE OR RESOLUTION STATUS HVAC dependencies are addressed in the This F&Ois fault trees where needed, and discussions CLOSED.

are provided in individual system notebooks (SY.3 series) and the dependency notebook (SY.1 ). An integrated HVAC dependency document has not been prepared.

Regarding specific dependencies: The charging pumps and the emergency switchgear room already have ventilation dependencies included in the PRA model.

The other major components with potential HVAC dependencies were evaluated and found to have a negligible ventilation dependency. Those SSC's are as follows:

1) Low Head Safety Injection pumps - The LHSI pumps take suction from the cold RWST early during a LOCA. After Recirculation Mode Transfer, the sump water will be cooled by the RSHX's, so that LHSI ventilation is not necessary. 2) Outside Recirculation Spray pumps - The CS subsystem provides approximately 300 gpm 45F water from RWST to each ORSP.

There is no ceiling in the ORSP rooms. It is not a closed room. Hence, the room ventilation is not necessary. 3) Emergency Diesel Generators - The EDG's have self-contained cooling systems. 4) Alternate AC Generator - The AAC DG has a self-contained cooling system. 5) Auxiliary Feedwater pumps - These pumps take suction from the ECST or a backup system that is at ambient temperature. They are therefore self-cooling and require no HVAC.

6) Station batteries - The heat load in this room is the batteries themselves and the heat load from the batteries may be ignored.
7) Turbine building SSC's - The potentially important SSC's in the TB are the MFW and the CN pumps, in case they are needed as a backup to the AFW system. On a reactor trip, the FW heaters no longer function as heaters and both CN and MFW flows are at relatively cold condenser temperatures. The Turbine Building SSC's are therefore self-cooling.

Serial No.16-263 Docket Nos. 50-280/281 Page 17 of 41 There are only.3 Category C F&Os that need to be addressed and they are listed in below:

Category C F&Os that Need to be Addressed F&O DESCRIPTION DE-1 Develop a system to initiating event dependency matrix to better show the dependencies modeled for each initiator. (PRA Configuration Control Database (PRACC) record 4023)

DE-4 Develop master dependency matrices for front-line to front-line, for support to front-line, and initiator to system dependencies. (PRACC record 4023)

SY-13 Update references that support mission times that are less than 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. (PRACC record 4012)

All three of these involve documentation issues that do not impact the PRA model results and do not affect the technical adequacy of the PRA model. Records have been added in the PRACC database to track the above tasks to completion.

2004 SPS Scientech Human Reliability Analysis (HRA) Follow-On Peer Review This peer review of the 2003/2004 update to the Surry HRA was performed in accordance with the ASME PRA Standard and RG 1.200. The HRA had previously been peer reviewed as part of the WOG PRA peer review but had undergone a sufficiently substantial revision in methodology during the 2003 model update (S03A model) that Dominion determined that another peer review was warranted. The pertinent results of the previous WOG Peer Review were re-examined during this process.

The F&Os from the PRA peer review were prioritized into categories A through D based upon importance to the completeness of the model. Categories A and B F&Os are considered significant enough that the technical adequacy of the model may be impacted.

Categories C and D are considered minor.

Category A and B items from the 2004 Scientech Peer Review are listed and dispositioned below:

LEVEL OF F&O SIGNIFICANCE 2J A/B 4J-2 A/B 4J-3 A/B 4J-4 A/B Serial No.16-263 Docket Nos. 50-280/281 Page 18 of 41 IMPORTANCE HRA SCIENTECH PEER REVIEW COMMENTS TO APPLICATION In the Surry HRA Post-Initiator report the both the HCR/ORE and CBDTM HRA methods use timing data that Addressed with was derived from operator surveys. The timing data obtained based on the operator survey is a key input, Sensitivity #1 and using this method the key input is driven by an assumed weighting. This becomes a key assumption as it appears this can significantly drive the HRA results, and thus the impact of this assumption should be evaluated via a sensitivity analysis.

The following comments are made relative to the detailed analysis documentation associated with each Addressed with basic event in the Surry HRA Post-Initiator Notebook. These comments apply to the detailed analysis of each Sensitivity #1 human failure event.

1. Section 2.4.1 Detailed Analysis of HEP-lE0-1, HEP-2E0-1 Usage of the Basic Event. Need to explain the mismatch between the "IPE usage" bullet with that at the end of the section (current fault trees}.
2. Section 2.4.1 Detailed Analysis of HEP-lE0-1, HEP-2E0-1 HFE Usage. (Related to comment #1 in this section} - Add a description of the differences between scenarios (e.g. which case is the bounding case, what are the differences between scenarios and how/why the HFE applies to all scenarios modeled}. For example, in Section 2.4.2 the Detailed Analysis of HEP-lE0-4, HEP-2E0-4 shows the current model usage expands from the SINOHHl to CHNOCHl. The IPE usage was for only S2 LOCAs but this BE could be modeled in steam/feedwater line breaks, consequential LOCAs such as RCP seal LOCA, and other initiators.
3. Section 2.4.14 Detailed Analysis of HEP-lE0-10, HEP-2E0-10 CBDT. The cues should be stated.

The following comments are made relative to the detailed analysis documentation associated with each Addressed with basic event in the Surry HRA Post-Initiator Notebook. These comments apply to the detailed analysis of each Sensitivity #1 human failure event.

Section 2.4.1 Detailed Analysis of HEP-lE0-1, HEP-2E0-1 Time Window. Add more specific references for the time window (e.g. the MAAP run document}.

The following comments are made relative to the detailed analysis documentation associated with each Addressed with basic event in the Surry HRA Post-Initiator Notebook. These comments apply to the detailed analysis of each Sensitivity #1 human failure event.

Section 2.4.11 Detailed Analysis of HEP-lE0-16, HEP-2E0-16 Cognitive and Execution. Many, if not all, CBDT cognitive modeling comes out to be 3E-3. Execution inconsistencies such as stating 15 valves to open but modeled as a simple action. Many, if not all, execution modeling comes out to be 1E-4. For example, in Section 2.4.114 Detailed Analysis of HEP-1E2-4, HEP-2E2-4 Execution, one of the required actions stated in the "Notes" is to locally close valves but this modeled as a simple action inside of the control room. This comment applies to HEP-1E3-3 as well.

LEVEL OF F&O SIGNIFICANCE SJ-1 A/B SJ-2 A/B 7B A/B Serial No.16-263 Docket Nos. 50-280/281 Page 19 of 41 IMPORTANCE HRA SCIENTECH PEER REVIEW COMMENTS TO APPLICATION In the Surry HRA Post-Initiator Notebook, the following dependency issues need to be addressed.

Addressed with

1. Section 2.4.4 Detailed Analysis of HEP-lE0-8, HEP-2E0-8 Dependency. I would imagine this HFE occurs in Sensitivity #1 cutsets along with SIS manual actuation (HEP-lE0-4, HEP-2E0-4) and there may be a cognitive dependence.
2. Section 2.4.8 Detailed Analysis of HEP-lE0-13-Sl, HEP-2E0-13-Sl Dependence. Good bullet identifying the relationship with other basic events. The next step is to describe how this dependence is evaluated (also applies to HEP-lE0-16).

In the Surry HRA Post-Initiator Notebook, the following dependency issues need to be addressed.

Addressed with The Surry decision tree for evaluating dependencies is unique and key assumptions should be evaluated via Sensitivity #1 sensitivity studies. For example, in the Surry approach the time window (total time available) has more impact than on the time that the actions would occur. Specifically, if two actions occurred within 5 minutes of each other but there was 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> available, then the dependence is assessed as low.

There are numerous places in the Surry HRA where exceptions are taken to standard methodologies, or Addressed with where specific modeling assumptions have been made. Specific comments have been provided on some of Sensitivity #1 these in other Observations. Where such exceptions and assumptions are used, however, it is important that they be obvious to users of the PRA, and that their potential impact on PRA results be examined, understood, and documented. Examples of methodology exceptions or modeling assumptions that should be identified as assumptions, and evaluated (e.g., via sensitivity studies) for consideration as "key assumptions" (i.e., those for which use of alternate assumptions might result in significantly different results) include:

1) Use of a dependency model different than defined in ASEP, for the pre-initiator actions
2) Approach and assumptions related to the interpretation and quantification averaging of the Operator Survey results
3) Lack of treatment of internal flooding and external events human actions
4) Applicability (or limitations on applicability) of actions relative to LERF
5) Basis for assignment of sigma values for the Pc calculations using the HCR model
6) Basis for extent of cutset review in looking for dependencies among HFEs in cutsets
7) Basis for assignment of error factors (different than ASEP) for the post-initiator actions

Serial No.16-263 Docket Nos. 50-280/281 Page 20 of 41 2010 SPS PRA Focused Peer Review The. Surry PRA model underwent a focused peer review in February 2010 using the PRA Peer Review Certification process performed by the Pressurized-Water Reactor Owners Group (PWROG). To determine whether a full scope or focused peer review was necessary, the changes to each of the model elements were reviewed to assess whether the changes involved either of the following:

new methodology significant change in the scope or capability If changes to an element involved either a new methodology or a significant scope or capability change, then the element requires a peer review as required in the ASME PRA standard (RA-Sb-2005). Based on the assessment of the changes to each PRA model element, a peer review was performed on the elements shown below:

Peer Reviewed Elements ELEMENT HIGH LEVEL REQUIREMENT IE - Initiating Events Initiating Events Review support system initiator modeling meets SRs IE-C6, C7, CB, C9, and C12.

AS - Accident Accident Sequence Review upgraded event trees for SBO, RCP Seal, LOCA,.

Sequence SGTR and ATWS meets all HLRs for AS.

HR - Human Reliability Human Reliability Review implementation of SPAR-H methodology meets Analysis Analysis HLR-HR-G.

IF - Internal FloodinQ Internal FloodinQ Review internal floodinQ model meets all HLR5 for IF.

QU - Quantification Quantification Review conversion to CAFTA meets HLRs for QU-B, C, and D.

The AS and IF elements required a full review against the high level requirements (HLRs). However, changes in the IE, HR and QU elements only required specific HLR verification. The review process included:

Serial No.16-263 Docket Nos. 50-280/281 Page 21 of 41 Review of the PRA model against the technical elements and associated supporting requirements (SRs) - Focus is on meeting capability category II At the SR level, the review team's judgment was used to assess whether the PRA meets one of the three capability categories for each of the SRs.

Evaluation of the PRA model is supported by:

o NEI 05-04 process o Addendum to ASME/ANS PRA Standard RA-S-2008 o SR interpretations from ASME website o NRC clarifications and qualifications as provided in Appendix A of RG 1.200, Rev. 2 o Reviewers' experience and knowledge o Consensus with fellow reviewers o Input and clarifications from the host utility The gaps identified during the self-assessment that remain to be addressed are listed in Table below:

2010 SPS Peer Review Remaining Gaps that Need to be Addressed1 NEI TITLE DESCRIPTION ELEMENT I CURRENT STATUS I IMPORTANCE TO APPLICATION ASMESR COMMENT Gap#1 For each flood area, identify the IFS0-81 No documentation on why None. This is judged to be a documentation potential sources of flooding.

floods in containment were consideration only and does not affect the technical screened out.

adequacy of the PRA model or sequences relevant to this application.

Gap#2 The NRC clarification for Cat II says to IFSN-A6 No documentation discussing This is judged to be a primarily a documentation address jet impingement, humidity, etc.

how jet impingement, pipe wipe, consideration only. This issue does not affect qualitatively using conservative humidity and other types of sequences relevant to this application.

assumptions.

failures impact plant systems.

NEI Title Description Element/

ASMESR Gap#3 Document the relative contribution of LE-G3 contributors to LERF.

Gap#?

Document the system functions and SY-C2 boundaries.

Gap#9 Initiating Event Fault Tree Modeling.

IE-C10 IE-C12 Gap Use of SPAR-H methodology, which HR-E3

  1. 10 does not meet the intent of several SRs HR-G4 in the HR element.

HR-G6 HR-12 HR-13 HR-E4 HR-G1 HR-G3 HR-G5 Gap Walkdown sheets do not contain all the IFS0-82

  1. 11 requested information.

IFQU-A9 Current Status I Comment No documentation of LERF contributions for accident sequences.

All documentation requirements are considered met except for completion of walkdown checklists.

IE-C10: Not all possible combination of cutsets are

captured, IE-C12: No comparison with generic sources for initiating events modeled using fault trees.

New Human Error Probabilities (HEPs) added to the SPS PRA were based on SPAR-H. The Peer Review identified the SPAR-H methodology is not a consensus model and has some limitations.

IFS0-82: Complete the walkdown sheets and verify no impact to IF events.

IFQU-A9: Similiar to IFS0-82, need to clearly document the spatial relationship between flood sources and PRA equipment.

Serial No.16-263 Docket Nos. 50-280/281 Page 22 of 41 Importance to Application None. This is judged to be a documentation consideration only and does not affect the technical adequacy of the PRA model.

None. This is judged to be a documentation consideration only and does not affect the technical adequacy of the PRA model.

A fault tree/cutset review indicated that this issue does not impact this application.3 Comparison with generic sources and similar plants is expected to render similar results to the I Es compared.4 Any impact to this application of findings related to initiating events are bounded by the results of Sensitivity #3 which increases LOOP frequencies in the S007Aa model by a factor of 10.

The impact of this gap on this application was evaluated by performing a sensitivity study (Sensitivity

  1. 1) which multiplies HEPs in the S007Aa model by 10.

This sensitivity demonstrates that this issue does not impact the results of this analysis.

This is judged to be a primarily a documentation consideration only. This issue does not affect sequences relevant to this application.

Notes:

Serial No.16-263 Docket Nos. 50-280/281 Page 23 of 41 Note 1: Gaps 4, 5, 6 and 8 have been addressed in 8007 Aa.

Note 2: Gaps 9 through 11 were identified during the 2010 PWROG focused PRA peer review.

Note 3: IE-C10: If fault-tree modeling is used for initiating events, CAPTURE within the initiating event fault tree models all relevant combinations of events involving the annual frequency of one component failure combined with the unavailability (or failure during the repair time of the first component) of other components. Following are the Peer Review comments with applicability response to this LAR:

F&O: 2-2, 2-3 Assessment: Cat 1-111 is NOT Met Basis: A review of SSIE cutsets found that they are not adequate due to:

(1) The cutsets do not include all possible combinations; for example, (a) Train A CCW pump fails-to-run and Train B CC pump fails-to-start is in the cutset, but other failure events that could lead to Train B CCW pump fails-to-start such as AC failure, No Actuation Signal are not included; (b) relief valve failure is not showing up in the cutsets of loss of CCW

Response

Fault Tree review indicated that these types of basic events are modeled but are truncated out of the final results.

Any impact to this application of findings related to initiating events are bounded by the results of sensitivity #3 which increases LOOP frequencies in the S007Aa model by a factor of 10. Therefore, this F&O does not impact the result of this analysis.

(2) Cutsets including both PROB-xxxxxB-STDBY (Train B) and -PROB-xxxxxA-STDBY (Train A) events may be underestimating the impact

Response

Cutset review indicated that alignment probabilities were not significant to this evaluation.

Serial No.16-263 Docket Nos. 50-280/281 Page 24 of 41 (3) Surry SSIE models do not include passive failures (i.e. pipe breaks affecting only the source system) which are screened from the flooding analysis. These failure modes may be important in the SSIE model. For the CC system the model includes this IE, (%FLOOD-AB-SPRAY-CCP1ABCD SPRAY IN AUX BLDG 2'-0" ELEV IN VICINITY OF CC PUMPS 1-CC-P-1AIB/CID)

Response

Inclusion of these low probability passive failure modes would not impact the accident scenarios that are significant to this application (i.e. LOOP). Any impact to this application of findings related to initiating events are bounded by the results of sensitivity#3 which increases LOOP frequencies in the S007 Aa model by a factor of 10.

Therefore this F&O does not impact the result of this analysis.

Note 4: IE-C12: COMPARE results and EXPLAIN differences in the initiating event analysis with generic data sources to provide a reasonableness check of the results.

Following are the Peer Review comments with applicability response to this LAR:

F&O: 3-4 Assessment: Cat 1-111 is NOT Met Basis: Comparison of IE frequencies to industry mean values is performed in SPS PRA Notebook Part Ill, Volume IE.3, Revision 1, Table 2-4 by comparing 7 modeled Initiating Events with 5 other unit results and to NUREGICR-5750. The remaining 12 Initiating Events (with Fault Trees) are not compared. Other Initiating Events are not compared.

Response

This is primarily a documentation concern. The Loss of SW IE was compared to the standard and the industry means and was demonstrated to be reasonable. The SPS Loss of SW IE is unique due to the gravity feed configuration. The comparison of the modeled I Es demonstrated that the Surry frequencies were within the range of the standard and similar plants. The IEs that were not compared are expected to have similar results. Any impact to this application of findings related to initiating events are bounded by the results of sensitivity#3 which increases LOOP frequencies in the S007 Aa model by a factor of 10. Therefore, this F&O does not impact the result of this analysis.

Serial No.16-263 Docket Nos. 50-280/281 Page 25 of 41 The following F&Os from the 2010 SPS PRA Focused Peer Review are considered closed:

2010 SPS Peer Review Closed F&Os DESCRIPTION F&OCOMMENT DOMINION RESPONSE STATUS F&O:

Mission time for The turbine driven AFW pump logic used The modeling of the TDAFW pump failure to run This F&O 1-10 TDAFW during under gate U1-SGC-BO is based on a 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> with a mission time of 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> instead of 4 question is a SBO is 24 mission time. This may be somewhat hours is conservative. The basic approach considered hours, which is conservative since the turbine driven pump is taken for adding different running failure basic CLOSED.

conservative.

only credited for 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> in SBO.

events with different mission times is that if the 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> mission time basic event has a high risk importance, then a new basic event with a mission time for the sequence would be developed. Since the importance of the TDAFW running failure basic events is not significant, a separate basic event was not added.

F&O:

Consider Recovery events are added to cutsets based The two recovery actions that the reviewer This F&O 3-5 adding some on post-processing with QRECOVER and identified as not being in the Surry PRA model question is recovery basic plant-specific rule file as discussed in SPS but were calculated in the HR.3 model notebook considered events to the HR.3 notebook, Section 2.2, and the QU.1 were removed from the model during the CLOSED.

fault tree model notebook. Some recovery actions (e.g., REC-transition from the Winnupra model to the Cafta instead of FTSCC and REC-FTSBC) should be modeled model. Since the standby pumps get an auto-adding as part as HEPs in the FT so all pertinent cutsets are start signal if the running pump fails, these of post-generated and dependency assessed. REC-recoveries were AND'd with the failure of the quantification FTSCC and REC-FTSBC are listed in HR.3 as pressure switch. Since these were not showing processing recovery events; however, they are not utilized up in the cutsets, it was determine that credit for using in the quantification process. These actions the operator recovery would not be included. If QRECOVER.

are typically utilized in Initiating Event fault these pressure switch failure basic events had a trees in conjunction with auto-start failures.

high importance, then adding the recovery credit Not modeling these actions may cause cutsets would be considered.

not to be generated, dependencies not evaluated, and overall results impacted.

DESCRIPTION F&OCOMMENT F&O:

Use of SPAR-H The plant's approach to analyzing HEPs is 3-19 for HRA has more involved than the Category I limited requirements (it is actually closer to Category accounting for 111111), but it does not address all of the PSFs Performance identified for the Category 11/111 requirements (a Shaping Factors.

limitation of the SPAR-H method); therefore, MET was selected for Category I. While SPAR-H methodology is close to meeting CC 111111, one of the limitations is that the PSFs are limited to the eight chosen. Additionally, each of the eight PSFs should be evaluated for interaction impacts which are not covered by the method.

F&O:

QU.2 does not SPS QU.2 Notebook Section 2.3.2 discusses 2-8 include detailed the dominant core damage accident description of sequences and has a detailed description of the CDF and the top 5 sequences. Section 2.3.3 discusses LERF cutsets.

the top CDF cutsets but does not document the review of a sample of significant cutsets.

It is noted that Section 2.4.2 documents the review of nonsignificant cutsets. SPS QU.2 Notebook documents a review of the top 5 sequences but has no review of a sample of significant cutsets.

2012 SPS PRA Focused Peer Review Serial No.16-263 Docket Nos. 50-280/281 Page 26of 41 DOMINION RESPONSE STATUS Since this F&O relates to using SPAR-H, and This F&O F&O 3-18 indicates that SPAR-H method is not question is a valid method to meet Cat II, then this F&O will considered be closed out to F &O 3-18.

CLOSED.

Detailed descriptions of the CDF and LERF This F&O cutsets are contained in the worksheets named question is "Top 100 U1 CDF Cutsets" and "Top 100 U1 considered LERF Cutsets" in Attachment 3 of the QU.2 CLOSED.

notebook.

A focused scope Peer Review of the SPS PRA model. against the requirements of the ASME I ANS PRA standard RA-Sb-2005 and any Clarifications and Qualifications provided in the NRC endorsement of the Standard contained in Revision 2 to RG 1.200 was conducted in June 2012.

In the course of this review, thirty (30) new F&Os were prepared, including twenty-one (21) suggestions, and nine (9) findings. Many of these F&Os involve documentation issues. The 21 *suggestions do not affect the technical adequacy of the PRA model and have no impact on the results of this evaluation. The following 9 findings have been evaluated as described below:

F&O ELEMENT 1-2 IE-C6 1-6 QU-B7 1-8 DA-05 Serial No.16-263 Docket Nos. 50-280/281 Page 27 of 41 Nine Findings from 2012 SPS PRA Focused Peer Review F&O DETAILS POSSIBLE RESOLUTION BASIS OF SIGNIFICANCE IMPORTANCE TO APPLICATION Scenario 1 in AS.2, Attachment 3, Appendix ISLOCA-F is Expand the discussion to include the The calculated impact on CDF There is no impact on CDF or LERF screened even though the event frequency would be probability of operator failure to secure is small (<1%), the impact as this is a documentation greater than 1.0E-06 (calculated as 3.85E-06). This HHSI and other failure modes that needs to be more fully enhancement (Ref. PRACC 16415),

scenario should be reconsidered to ensure the screening would result in continued HHSI documented to ensure the therefore this gap has no impact on is appropriately justified using the criteria specified in operation given a rupture in the LHSI screening criteria is met.

this application.

IE-C6.

piping.

This guidance does not seem to be technically supported Remove the mutually exclusive logic The impact of the removal of A bounding sensitivity study by NUREG/CR-5485 Section 5.4.4 which only supports for common cause failures or modify the basic event combinations evaluating the removal of the removal of combinations of two common cause failure the logic to ensure only combinations cannot be estimated based on mutually exclusive logic for common events where the combinations include the same pump of events including a common available information.

cause failures results in an increase (e.g., CCF of Pumps A and B in combination with CCF of component and failure mode (e.g.,

However, because this process in the baseline CDF and LERF pumps A and C). Further, NUREG/CR-5485 Section 5.2 Component A Independent Failure to may impact the importance of values (Ref. PRACC 16418). The notes that NUREG/CR-4780, Volume 1 discusses Start in combination with CCF of high safety significant impact of this gap on this application conditions under which these combinations may be valid Component A and B to Start) are components, it is designated as was evaluated by performing a (see NUREG/CR-4780, Volume 1, Section 3.3.1).

removed.

a finding.

sensitivity study (Sensitivity #2) which multiplies CCFs in the S007Aa model by 10.

A global assumption is made that staggered testing is Provide justification for application of The alpha factors for A bounding sensitivity study applicable to all common cause events SPS DA.3 the staggered testing assumption to

.components tested on a non-changing all CCFs from "staggered Revision 5, Section 2.2.1, Item 1). Typically, some components tested on an outage staggered basis are typically basis" to "non-staggered basis" components such as containment isolation valves, HHSI frequency including verification that higher than those tested on a results in an increase in the baseline isolation valves, and others may only be tested during the redundant components are tested by staggered basis. Therefore, CDF and LERF values (Ref. PRACC outages. Additional justification for application of the different personnel at different times or this could be a significant 16419. The impact of this gap on staggered testing assumption to those components tested apply alpha factors based on a non-impact on CDF or LERF

  • this application was evaluated by on an 18 month basis during outages is needed.

staggered testing scheme to those depending on the specific

, performing a sensitivity study components.

. components affected.

(Sensitivity #2) which multiplies CCFs in the S007Aa model bv 10.

F&O ELEMENT F&O DETAILS 1-10 DA-06 The AAC diesel is included in a common cause group with the other emergency diesel generators even though SY-B3 SPS notebook SY.3.EP states that "The AAC diesel has a different manufacturer for the generator and the diesel engine and is unique to both units."

SPS DA.3 addresses this in an assumption that states that "If SBO diesel is modeled as one of the EDG CCF groups, because of the less similarity between the EDG and SBO diesel, the alpha factor of 3 of 3 EDGs CCF to run may be set as 1.06E-2*0.9 = 9.54E-3 and the alpha factor of AAC diesel and 2 EDGs CCF to run may be set as 1.06E-2

  • 0.1 = 1.06E-3." However, there is no technical basis for the factor of 10 reduction, only a qualitative discussion, yet this is dispositioned as not being a source of uncertainty.

2-2 IE-C3 The issue of ISLOCA flood propagation and steaming effects in the Safeguards Building is not adequately addressed. Section 2.4 of the IE.1 notebook states that flooding/spatial effects need not be considered because an unisolated ISLOCA was assumed to go directly to core damage. However, if there is a successful isolation prior to core damage, there is still a question about the effects of the water/steam that was already leaked. For example, AFW pump operation should be shown not to be impacted, as well as potential effects on the credited isolation valve itself.

The PRA staff researched the issue during the peer review and provided information that appears to justify the operability of the isolation valve, but additional analysis is reauired and needs to be documented.

POSSIBLE RESOLUTION There are two approaches that can be considered. The most defensible approach would be to identify all legitimate common elements between the EDGs and the SBO diesel, review the CCFWIN database to exclude diesel failure mechanisms that are not common between the Surry EDGs and the SBO diesel, and calculate the actual alpha factors.

The second approach would be to identify that the factor of 1 O reduction in the alpha factor is an estimate without a numerical basis, which makes it a plant-specific modeling uncertainty for Surry. Then sensitivity analyses could provide some insight into the importance the assumed factor (0.1, 0.2, 0.5, etc.) would have on the results.

For the successfully isolated lSLOCA sequences, consider potential flood and steam effects from water that leaked out the break prior to isolation.

Also, consider the potential for the isolation valve to be failed due to the effects.

Serial No.16-263 Docket Nos. 50-280/281 Page 28 of 41 BASIS OF SIGNIFICANCE IMPORTANCE TO APPLICATION The qualitative discussion of A bounding sensitivity study not all diesel CCF mechanisms evaluating the common cause group existing between the EDGs and of emergency generators results in the SBO diesel is legitimate.

an increase in the baseline GDF and However, the selection of 0.1 LERF values (Ref. PRACC 16420).

does not have a numerical The impact of this gap on this justification, and could application was evaluated by potentially be conservative or performing a sensitivity study non-conservative, and it is not (Sensitivity #2) which multiplies apparent the degree to which it CCFs in the SOO?Aa model by 10.

affects the results since no sensitivities were documented.

Any modeling assumption that could result in lowering the importance of the EDGs could impact applications such as MSPI.

Flood propagation and steam There is no impact on GDF or LERF effects may not be an issue, but as this is a documentation it cannot be determined for enhancement (Ref. PRACC 16421 },

certain without further therefore this gap has no impact on evaluation.

this application.

F&O ELEMENT F&O DETAILS 2-3 DA-A2 Regarding component boundaries, Section 3.3.1 of the CCF GARD (NF-AA-PRA-101-2062, Rev. 4) states, DA-D6

'When defining common cause failure events (and utilizing generic data concerning the probability of these events), the analyst must ensure that the component boundaries assumed for common cause failures are consistent with the boundaries used for the independent failures." DOM.DA.1 Rev. 2 states "To ensure consistency between the generic database and the plant specific database, the component boundary needs to be verified. This notebook documents the generic database with component boundaries defined according to NUREG/CR-6928 (Ref. 6.1 ). This generic database shall be applicable to all of the Dominion PRA models."

However, Assumption 8 in Section 2.2.1 of SPS DA.3 Rev. 5 states "CCF data boundaries were not compared to the boundaries of DOM DA.1. Generic common cause failure factors were used because no plant specific common cause failures were identified. A review of the generic common cause failures indicates that its boundaries were wider than DOM DA.1 boundaries."

POSSIBLE RESOLUTION Review CCF (and even the independent failure data) for component boundary consistency with the generic data and CCF factors.

Serial No.16-263 Docket Nos. 50-280/281 Page 29 of 41 BASIS OF SIGNIFICANCE IMPORTANCE TO APPLICATION While it is recognized that There is no adverse impact on CDF modeling extra events (such as or LERF as this is a model diesel generator output enhancement and as stated in the breakers when they are part of description adds modeling the diesel component boundary conservatism (Ref. PRACC 16422),

in NUREG/CR-6928) is therefore this gap has no impact on conservative, for accuracy and this application.

compliance with the Dominion GARD and DOM.DA.1 notebook, component boundaries should be consistent with the data.

F&O ELEMENT F&O DETAILS 2-5 SY-B3 The CCF grouping appears to have been performed properly for pumps and some MOVs examined.

DA-A1 However, checks of the Electric Power system model and check valves in SI and FW models show CCF combinations that are missing. In the Electric Power system model, the CCF of buses, inverters, breakers and fuel oil pump strainers (possibly other components as well) were modeled for complete failure of all in the group, but not for smaller numbers. For example, Table 3.8-1 shows 1 EETFM-C8-480TFM being comprised of eight transformers. However, failure of a group as small as 2 (e.g., transformer 1 H/1J) could be significant, as these transformers feed the 480V buses that power the 1A/2A and 1 B/2B recirculation spray pumps. While it is acceptable to model CCF of combinations greater than 4 jointly (as is stated in the Section 3.2.2 of the GARD, this means creating a joint probability that sums all the 5/8, 6/8, 718 and 8/8 combinations into one), the individual combinations of 2, 3 and 4 still need to be captured.

The other logic reviewed that are missing combinations are seen under gates 1-Sl-82, 1-Sl-236, 1-FW-27, 1-FW-28, 1-FW-29 and 1-FW-61/1-FW-62. These instances were identified in a short review of the system models, and the review team is concerned the problem is widespread.

Another item noted is Section 2.3 of the DOM.DA.3 notebook states "The Supply Breakers that feed the Emergency Buses, if there is a loss of off-site power, should be modeled for a common cause failure to open when the Emergency Diesel Generators are required to be running and supplying power to the emergency buses." This was not modeled in the EP fault trees (they would be expected under gates 1-EP-BKR-15H8-FTO and 1-EP-BKR-15J8-FTO-LC, etc.).

2-8 SY-B3 The DOM.DA.3 R3 notebook Section 2.3 states that CCF of air-cooled transformers would not be modeled. There DA-A1 is no mention of this in the EP system notebook. Many of the transformers modeled in the PRA are air-cooled but have CCF modeled. The Surry PRA model would need to be updated to match the assumption in the DOM DA.3 notebook.

POSSIBLE RESOLUTION Perform a thorough review of all system models to identify any missing CCF groups. It is acceptable to treat the combinations greater than 4 failures a single event as long as the combinations are summed and treated as complete system failure. For such cases, it is still necessary to model the combinations of 2, 3 and 4 failures.

Update the model to be consistent with the DOM DA.3 guidelines.

Serial No.16-263 Docket Nos. 50-280/281 Page 30 of 41 BASIS OF SIGNIFICANCE IMPORTANCE TO APPLICATION The missing CCF component A bounding sensitivity study of groups yields non-conservative additional CCFs results in an and potentially significant increase in the baseline CDF and results.

LERF values (Ref. PRACC 16423).

The impact of this gap on this application was evaluated by performing a sensitivity study (Sensitivity #2) which multiplies CCFs in the S007Aa model by 10.

This is presented as a finding There is no adverse impact on CDF because the PRA staff or LERF as this is conservative and identified that the assumption in will be removed from the model (Ref.

the DA.3 Rev. 3 notebook is PRACC 16424); therefore this gap correct and the model should has no impact on this application.

be updated.

F&O 2-9 ELEMENT F&O DETAILS DA-E3 EPRI generic CCF sources of model uncertainty are tabulated in Table 1 of the SPS DA.3, Rev. 5 notebook.

DA-A-2 notes that component boundaries are not consistent with the failure data, but states that this is a consensus model approach and not a souree of uncertainty for Surry. This should be considered a source of model uncertainty and/or be corrected.

Missing from the evaluation *of sources of model uncertainty are all SPS-specific assumptions, including those tabulated in SPS DA.3 Rev. 5 Section 2. 2.

POSSIBLE RESOLUTION Evaluate the plant-specific sources of model uncertainty related to the Surry CCF analysis.

Serial No.16-263 Docket Nos. 50-280/281 Page 31 of 41 BASIS OF SIGNIFICANCE IMPORTANCE TO APPLICATION Sources of uncertainty specific There is no impact on CDF or LERF to the Surry CCF analysis need as this is a documentation to be considered.

enhancement (Ref. PRACC 16425),

therefore this gap has no impact on this application.

Review of Open Issues against the PRA Model (PRA Configuration Control)

The PRA Configuration control database (PRACC) was reviewed in order if any known modeling issues open against the S007 Aa model could impact the results of this analysis. The following open issues were identified from Surry's PRACC database. These issues were addressed either by adjusting the S007 Aa PRA model used to perform this risk evaluation, or by performing a sensitivity study to demonstrate that the issue was not significant to this analysis.

ID DATE IDENTIFIED DESCRIPTION IMPORTANCE TO APPLICATION 1790 3/8/2004 Evaluate 1(2)CWHEP-LIC-1(2)06NB via HRA methods. Current value is Addressed with Sensitivity #1 selected to be consistent with 1CWHEP-LIC-LVL.

2509 3/6/2007 According to industry benchmark survey, consequential LOOP after a unit Addressed with Sensitivity #3 transient should be included in the model.

During the 2008 model update, the MAAP runs for the different scenarios 9486 10/21/2008 were not completed in time before the model change freeze date. Need to Addressed with Sensitivity #1 update the HEPs in the HR.2 notebook using the times calculated from the MAAP runs.

ID DATE IDENTIFIED 11521 7/7/2010 11522 7/7/2010 DESCRIPTION In 2002, an operator survey was complete to document timing estimates from operators of various experience levels. The timing results from the survey are used in the HRA for the HEPs. Table 6.1 of HR.2 states "the response times for operator actions may be estimated by procedure talk through or operator surveys. Therefore, this is retained as a source of uncertainty." For the SPAR-H HEPs, time available is based on engineering judgment. The delay (TDelay), action(TM) and response times (T1/2) are conservative estimates based on a table top review of the procedures as well as input from other HEPs of similar actions and events.

For the SPAR-H HEPs recently added to the SPS PRA model, the time available to complete the actions were not based on applicable generic studies (e.g. thermal/hydraulic analysis or simulations from similar plants) but on engineering judgment. In addition, prior HEPs were developed using the results of a 2002 survey and not on thermal/hydraulic analysis.

(This F&O originated from SR HR-G4)

Associated SR(s): HR-G4 SPS HR.2 does not check the consistency of the post-initiator HEP quantifications. A comparison of previous HEP values with current HEP values is found in the QU.2 notebook supporting files but no relative comparisons are made.

A review of the SPS HEPs relative to each other to check for reasonableness has not been performed.

(This F&O originated from SR HR-G6)

Associated SR(s): HR-G6 Serial No.16-263 Docket Nos. 50-280/281 Page 32 of 41 IMPORTANCE TO APPLICATION Addressed with Sensitivity #1 Addressed with Sensitivity #1

ID DATE IDENTIFIED 11S23 7/7/2010 11S24 7/7/2010 DESCRIPTION The delay (TDelay), action TM and response times (T1/2) are conservative estimates based on a table top review of the procedures as well as input from other HEPs of similar actions and events.

The newly added SPAR-H HEPs based the required time to complete actions on a table top review of the procedures and input from other procedures.

To meet CC II, base the required time to complete the actions (for significant HEPs) on action time measurements in either walkthroughs or talkthroughs of the procedures or simulator observations.

(This F&O originated from SR HR-GS)

Associated SR(s ): HR-GS Several documentation issues were identified:

1. Table 4 of HR.4 contains an error factor for each of the analyzed groupings of dependent operator errors. However, there is no explanation of how the error factor was derived. The equation for deriving the error factor is contained in Attachment 3, HEP Replacements worksheet, in HR.4.

(This F&O originated from SR HR-11)

Associated SR(s): HR-11, HR-12 Serial No.16-263 Docket Nos. 50-280/281 Page 33 of 41 IMPORTANCE TO APPLICATION Addressed with sensitivity #1 Addressed with Sensitivity #1

ID DATE IDENTIFIED 11526 7/7/2010 DESCRIPTION

      • Cloned from Record 11524***

From the Surry 2010 Peer Review report documented in Surry notebook Part IV Appendix A.3.

This F&O contained several different issues. Thus, this PRACC record was cloned so that each issue has its own PRACC record.

Several documentation issues were identified:

3. The SPAR-H HEPs recently added to the SPS PRA model are documented in HR.2. Four HEPs noted in Table A-2 (New HEPs Added) that were evaluated, do not appear in the Fault Tree. One new HEP listed (HEP-CPORTGENRMP) was not analyzed and is also not in the FT. New HEPs added for the recent model update were not necessarily covered by the 2002 survey results. System Analysis notebooks and review of HR.2 does not indicate that simulator observations or talkthroughs with operators were performed. For the SPAR-H HEPs recently added to the SPS PRA model, the time available to complete the actions were not based on applicable generic studies (e.g. thermal/hydraulic analysis or simulations from similar plants).

(This F&O originated from SR HR-11)

Associated SR(s): HR-11, HR-12 Serial No.16-263 Docket Nos. 50-280/281 Page 34 of 41 IMPORTANCE TO APPLICATION Addressed with Sensitivity #1

ID DATE IDENTIFIED 11538 7/8/2010 DESCRIPTION From the Surry 2010 Peer Review report documented in Surry notebook Part IV Appendix A.3.

SPS GARD NF-AA-PRA-101-2052 states in Section 3.5, "the SPAR-H model is not recommended where more detailed analysis of diagnosis errors is needed" and references NUREG/CR-1842 for more information. The NUREG states "This approach results in a somewhat 'generic' answer that is sufficient for some of the broad regulatory applications for which SPAR-H is intended, but perhaps is insufficient for detailed plant-specific evaluations (a limitation)"

and also references NUREG-1792. This NUREG states "detailed assessments of the significant HFE contributors should be performed."

The SPAR-H methodology is not a consensus model and seldom used in plant specific utility PRAs. Referenced documents show it should not be used to obtain detailed results. Additionally, it cannot be assumed that conservative results are obtained by SPAR-H as the evaluation of PSFs better than nominal can produce nonconservative values.

(This F&O originated from SR HR-G1)

Associated SR(s): HR-G1 Serial No.16-263 Docket Nos. 50-280/281 Page 35 of 41 IMPORTANCE TO APPLICATION Addressed with Sensitivity #1

ID DATE IDENTIFIED 11568 7/13/2010 12796 4/19/2011 DESCRIPTION From the Surry 2010 Peer Review report documented in Surry notebook Part N Appendix A.3.

The analysis uses an "engineering judgment" approach to dependency analysis which considers most "recognized" PSFs. Most of the dependencies are associated with one or two factors, and it is not clear how all of the "recognized" factors affect any single dependency analysis. There is no comparison of the "engineering judgement" based results to results that would be obtained from using other techniques such as the HRA calculator. A comparison of the Surry dependency results with those obtained from using an available dependency calculator produced the same results if only one PSF were considered. Also, differences were obtained when comparing 2-and 3-error combination dependencies.

Newer techniques for analyzing dependency are available. These techniques allow consideration of multiple PSFs during the analysis.

(This F&O originated from SR HR-G7)

Associated SR(s): HR-G7 Surry has had two LOOP events in the last few years. On October 7, 2006, a plant centered LOOP occurred due to turbine building siding getting blown off and landing on RSST bus ba,rs. On April 16, 2011, a tornado hit the switchyard causing a LOOP. The initiator frequency for LOOP used in the Surry PRA should be reviewed to determine if they need to be updated.

Serial No,16-263 Docket Nos. 50-280/281 Page 36 of 41 IMPORTANCE TO APPLICATION Addressed with Sensitivity #1 Addressed with Sensitivity #3

ID DATE IDENTIFIED 16418 7/26/2012 16419 7/26/2012 DESCRIPTION This guidance does not seem to be technically supported by NU REG/CR-5485 Section 5.4.4 which only supports removal of combinations of two common cause failure events where the combinations include the same pump (e.g., CCF of Pumps A and Bin combination with CCF of pumps A and C).

Further, NUREG/CR-5485 Section 5.2 notes that NUREG/CR-4780, Volume 1 discusses conditions under which these combinations may be valid (see NUREG/CR-4780, Volume 1, Section 3.3.1).

Therefore, It may be allowable to remove combinations of independent failure of Pump A and CCF of Pumps A and B in the same cutset. However, it does not seem valid to remove cutsets involving independent failure of Pump A and CCF of Pumps B and C. This is especially problematic in the mutually exclusive logic for the diesels where cutsets containing independent failure of the AAC diesel and common cause failure of two of the emergency diesels.

Since there are substantial differences in design between the AAC Diesel and the other diesels, it does not seem valid to remove these combinations.

(This F&O originated from SR QU-87)

APH Update on 04/11/2014 Removed all mutually exclusive logic on CCF combinations from AS-MUTX fault tree. This will allow the cutsets with a combination of a CCF event and independent event to be kept.

F&O 1-8 A global assumption is made that staggered testing is applicable to all common ca,use events (SPS DA.3 Revision 5, Section 2.2.1, Item 1 ).

Typically, some components such as containment isolation valves, HHSI isolation valves, and others may only be tested during the outages.

Additional justification for application of the staggered testing assumption to those components tested on an 18 month basis during outages is needed.

<This F&O oriainated from SR DA-05)

Serial No.16-263 Docket Nos. 50-280/281 Page 37 of 41 IMPORTANCE TO APPLICATION Addressed with Sensitivity #2 Addressed with Sensitivity #2

ID DATE IDENTIFIED 16420 7/27/2012 16422 7/27/2012 DESCRIPTION The AAC diesel is included in a common cause group with the other emergency diesel generators even though SPS notebook SY.3.EP states that "The AAC diesel has a different manufacturer for the generator and the diesel engine and is unique to both units."

SPS DA.3 addresses this in an assumption that states that "If SBO diesel is modeled as one of the EDG CCF groups, because of the less similarity between the EDG and SBO diesel, the alpha factor of 3 of 3 EDGs CCF to run may be set as 1.06E-2*0.9 = 9.54E-3 and the alpha factor of AAC diesel and 2 EDGs CCF to run may be set as 1.06E-2

  • 0.1 = 1.06E-3." However, there is no technical basis for the factor of 1 O reduction, only a qualitative discussion, yet this is dispositioned as not being a source of uncertainty.

(This F&O originated from SR SY-83)

Regarding component boundaries, Section 3.3.1 of the CCF GARD (NF-AA-PRA-101-2062, Rev. 4) states, "When defining common cause failure events (and utilizing generic data concerning the probability of these events), the analyst must ensure that the component boundaries assumed for common cause failures are consistent with the boundaries used for the independent failures." DOM.DA.1 Rev. 2 states "To ensure consistency between the generic database and the plant specific database, the component boundary needs to be verified. This notebook documents the generic database with component boundaries defined according to NUREG/CR-6928 (Ref. 6.1 ).

This generic database shall be applicable to all of the Dominion PRA models."

'However, Assumption 8 in Section 2.2.1 of SPS DA.3 Rev. 5 states "CCF data boundaries were not compared to the boundaries of DOM DA.1.

Generic common cause failure factors were used because no plant specific common cause failures were identified. A review of the generic common cause failures indicates that its boundaries were wider than DOM DA.1 boundaries."

(This F&O originated from SR DA-D6)

Serial No.16-263 Docket Nos. 50-280/281 Page 38 of 41 IMPORTANCE TO APPLICATION Addressed with Sensitivity #2 Addressed with Sensitivity #2

ID DATE IDENTIFIED 16423 7/27/2012 DESCRIPTION The CCF grouping appears to have been performed properly for pumps and some MOVs examined. However, checks of the Electric Power system model and check valves in SI and FW models show CCF combinations that are missing. In the Electric Power system model, the CCF of buses, inverters, breakers and fuel oil pump strainers (possibly other components as well) were modeled for complete failure of all in the*group, but not for smaller numbers. For example, Table 3.8-1 shows 1 EETFM-C8-480TFM being comprised of eight transformers. However, failure of a group as small as 2 (e.g., transformer 1 H/1J) could be significant, as these transformers feed the 480V buses that power the 1A/2A and 1 B/2B recirculation spray pumps.

While it is acceptable to model CCF of combinations greater than 4 jointly (as is stated in the Section 3.2.2 of the GARD, this means creating a joint probability that sums all the 5/8, 6/8, 7/8 and 8/8 combinations into one), the individual combinations of 2, 3 and 4 still need to be captured.

The other logic reviewed that are missing combinations are seen under gates 1-Sl-82, 1-Sl-236, 1-FW-27, 1-FW-28, 1-FW-29 and 1-FW-61/1-FW-62.

These instances were identified in a short review of the system models, and the review team is concerned the problem is widespread.

Another item n_oted is Section 2.3 of the DOM.DA.3 notebook states "The Supply Breakers that feed the Emergency Buses, if there is a loss of off-site power, should be modeled for a common cause failure to open when the Emergency Diesel Generators are required to be running and supplying power to the emergency buses." This was not modeled in the EP fault trees (they would be expected under gates 1-EP-BKR-15H8-FTO and 1-EP-BKR-15J8-FTO-LC, etc.).

(This F&O oriQinated from SR SY-B3)

Serial No.16-263 Docket Nos. 50-280/281 Page 39 of 41 IMPORTANCE TO APPLICATION Addressed with Sensitivity #2 7

ID DATE IDENTIFIED 16495 9/5/2012 17079 3/12/2014 DESCRIPTION EPRI TR-1025749, Losses of Offsite Power at U.S. Nuclear Power Plants -

2011, has been issued.

Loss of Offsite Power Initiating Event Frequencies have been updated.

Models need to update/revise/address the new LOOP generic data.

During 2011, there were seven losses of all offsite power (LOOP) at U.S.

nuclear power plants. The number of LOOPs in a given year has historically been between zero and six. Although there occasionally are years like 201 O when there is no loss of all offsite power at a U.S. nuclear plant or years like 2011 when there were seven events, such years are infrequent. It should also be noted that each loss of offsite power to a unit is counted as an event. In several instances, the initiating condition affected all units at a station. In 2011, severe weather conditions contributed to five of the LOOP events. East coast seismic activity contributed to two of the LOOP events.

The MAAP parameter file lists parameter MWCSTO (ECST initial water inventory) as 91, 137 gal referencing Surry AFW Design Basis Document (SDBD-SPS-AFW) Rev. 13. This value is different in the latest revision of Surry DBD, and the Tech Spec minimum is 96,000 gal. Consider revising parameter MWCSTO.

Also, HHSI pump flow curve (parameters ZHDP5 and WVPM5) references Rev.2 of ME-0771. The latest revision of this calculation is Rev.4 and it provides a slightly different pump curve (see test limit curve). Consider revising the HHSI pump curve per the latest revision of ME-0771.

4/15/2014 per email dtd.4/1/2014 from CBL NSA's ECST sizing calc SM-1612 seems to indicate that the ECST volume minimum setpoint is set so that the TS min available volume of 96,000 gal is met, accounting for unusable volume due to vortexing and suction nozzle position (page 12).

Serial No.16-263 Docket Nos. 50-280/281 Page 40 of 41 IMPORTANCE TO APPLICATION Addressed with sensitivity #3 Addressed with sensitivity #1

ID DATE IDENTIFIED 17162 4/28/2014 17182 4/28/2014 17187 4/28/2014 17920 42492

\\

DESCRIPTION Common cause and *routine system alignments are generally appropriately considered for complicated safety system initiating event fault trees.

However, for other systems (notably, electrical systems) there is no discussion or evidence of a review for initiators due to common cause of electrical systems or due to routine system alignments. GARD NF-AA-PRA-101-204C identifies that transformers, battery chargers, and inverters are candidates for common cause. These common cause failures are modeled in the core damage mitigation fault trees. However, these common cause failures are not considered as initiating events, particularly for RSST 4KV transformers, vital inverters, and 125VDC battery chargers. Also, for example, unavailability of a backup battery charger may drive a plant shutdown given loss of the normally operating charger.

In addition, could not find a discussion of why common cause blockage of service water travellina screens was not considered.

Dependency not assessed for recoveries credited in post-initiators using the CBDTM method.

There were some cases of unanalyzed dependency combinations found in the cutsets of cutset file U1-CDF-Avg Maintenance-R07.cut. Examples include cutsets 3119, 22480, 22642, 22643, 22868, 23050. The applicable truncation limits used in the dependency analysis need to be adjusted to eliminate unanalvzed combos in the cutsets.

Fuel oil tank 1-SW-TK-1 is not currently identified as a dependency for the Emergency Service Water pumps. These pumps are diesel driven and require fuel from 1-SW-TK-1 to operate. The SW Fuel Oil Subsystem consists of a storage tank, piping, and valves. The oil storage tank is in a separate room in the ESW House. The SW fuel oil tank capacity provides enough fuel oil to operate all three diesels for 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> and two diesels for an additional 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />. In order to satisfy TS 3.14.A.4, three emergency service water pumps must be operable and be able to service both units simultaneously.

FO dependency should be identified to accurately model the SW system design and operation.

Serial No.16-263 Docket Nos. 50-280/281 Page 41 of 41 IMPORTANCE TO APPLICATION Addressed with Sensitivity #3 Addressed with Sensitivity #1 Addressed with Sensitivity #1 Addressed with sensitivity #2

'.J f"