Text
Exelon Generation 200 Exelon Way Kennett Square. PA 19348 www.exeloncorp.com 10 CFR 50.46 April 7, 2016 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-0001 R.E. Ginna Nuclear Power Plant Renewed Facility Operating License No. DPR-18 N RC Docket No. 50-244
Subject:
2016 10 CFR 50.46 Annual Report
Reference:
Letter from J. Barstow (Exelon Generation Company, LLC) to U.S. Nuclear Regulatory Commission, "2015 10 CFR 50.46 Annual Report," dated April 9, 2015 The purpose of this letter is to submit the 10 CFR 50.46 annual reporting information for R.E.
Ginna Nuclear Power Plant. The referenced document is the most recent annual 10 CFR 50.46 Report report submitted to the U.S. Nuclear Regulatory Commission.
Two attachments are included with this letter that provide the current Ginna 10 CFR 50.46 status. Attachment 1 provides the Peak Cladding Temperature (PCT) "rack-up" sheets. , "Assessment Notes," contains a detailed description of each change/error reported.
There are no commitments contained in this letter. If you have any questions, please contact Ron Reynolds at 610-765-5247.
Respectfully, J~:JT j__Jy<--
Director - Licensing & Regulatory Affairs Exelon Generation Company, LLC Attachments: 1) Peak Cladding Temperature Rack-Up Sheet for R.E. Ginna Nuclear Power Plant
- 2) Assessment Notes cc: U.S. NRC Administrator, Region I U.S. NRG Project Manager, Ginna U.S. NRC Senior Resident Inspector, Ginna
ATTACHMENT 1 10 CFR 50.46 "Acceptance criteria for emergency core cooling systems for light-water nuclear power reactors" Annual Report of the Emergency Core Cooling System Evaluation Model Changes and Errors Assessments as of April 7, 2016 Peak Cladding Temperature Rack-Up Sheet for R.E. Ginna Nuclear Power Plant
Annual Report of the Emergency Core Cooling System Evaluation Model Changes and Errors Assessments as of April 7, 2016 Attachment 1 Peak Cladding Temperature Rack-Up Sheet for Ginna Page 1 of 2 PLANT NAME: Ginna ECCS EVALUATION MODEL: Small Break Loss of Coolant Accident (SBLOCA)
REPORT REVISION DATE: 4/7/2016 CURRENT OPERATING CYCLE: 39 ANAL VSIS OF RECORD Evaluation Model: NOTRUMP Calculation: Westinghouse CN-LIS-04-206, April 2005 Fuel: 422 Vantage+
Limiting Fuel Type: 422 Vantage+
Limiting Single Failure: Diesel Generator Failure to Start Limiting Break Size and Location: 2-inch Equivalent High Tavg Cold Leg Break Reference Peak Cladding Temperature (PCT) PCT= 1167 .0°F MARGIN ALLOCATION A. PRIOR LOSS OF COOLANT ACCIDENT (LOCA) MODEL ASSESSMENTS 10 CFR 50.46 report dated April 30, 2007 (Note 1) ~PCT= 0°F 10 CFR 50.46 report dated February 10, 2009 (Note 3) ~PCT= 0°F 10 CFR 50.46 report dated March 4, 2011 (Note 5) ~PCT= 0°F 10 CFR 50.46 report dated March 27, 2012 (Note 6) ~PCT= 0°F 10 CFR 50.46 report dated April 1, 2013 (Note 8) ~PCT= 0°F 10 CFR 50.46 report dated April 9, 2014 (Note 9) ~PCT= 0°F 10 CFR 50.46 report dated April 9, 2015 (Note 1O) ~PCT= 0°F NET PCT PCT =1167.0°F B. CURRENT LOCA MODEL ASSESSMENTS General Code Maintenance (Note 11) ~PCT= 0°F Effects of Fuel Reconstitution (Note 12) ~PCT= 0°F Total PCT change from current assessments L ~PCT= 0°F Cumulative PCT change from current assessments L I ~PCT I= 0°F NET PCT PCT =1167.0°F
Annual Report of the Emergency Core Cooling System Evaluation Model Changes and Errors Assessments as of April 7, 2016 Attachment 1 Peak Cladding Temperature Rack-Up Sheet for Ginna Page 2 of 2 PLANT NAME: Ginna ECCS EVALUATION MODEL: Large Break Loss of Coolant Accident (LBLOCA)
REPORT REVISION DATE: 4/7/2016 CURRENT OPERATING CYCLE: 39 ANALYSIS OF RECORD Evaluation Model: ASTRUM (2004)
Calculation: Westinghouse CN-LIS-05-11, April 2005 Fuel: 422 Vantage+
Limiting Fuel Type: 422 Vantage+
Limiting Single Failure: Loss of one train of ECCS flow Limiting Break Size and Location: Cold Leg Split Break Reference PCT PCT= 1870.0°F MARGIN ALLOCATION A. PRIOR LOSS OF COOLANT ACCIDENT (LOCA) MODEL ASSESSMENTS 1o CFR 50.46 report dated April 30, 2007 (Note 1) dPCT = 0°F 10 CFR 50.46 report dated May 4, 2008 (Note 2) dPCT =+ 37°F 10 CFR 50.46 report dated February 10, 2009 (Note 3) dPCT = 0°F 10 CFR 50.46 report dated March 26, 201 O (Note 4) dPCT = 0°F 10 CFR 50.46 report dated March 4, 2011 (Note 5) dPCT = 0°F 10 CFR 50.46 report dated March 27, 2012 (Note 6) dPCT = 0°F 10 CFR 50.46 report dated August 16, 2012 (Note 7) dPCT = +134°F 10 CFR 50.46 report dated April 1, 2013 (Note 8) dPCT = +75°F 10 CFR 50.46 report dated April 9, 2014 (Note 9) dPCT = +2°F 10 CFR 50.46 report dated April 9, 2015 (Note 10) dPCT = 0°F NET PCT PCT =2118.0°F B. CURRENT LOCA MODEL ASSESSMENTS General Code Maintenance (Note 11) dPCT = 0°F Effects of Fuel Reconstitution (Note 12) dPCT = +1°F Total PCT change from current assessments I dPCT = +1°F Cumulative PCT change from current assessments L IdPCT I= 1°F NET PCT PCT =2119.0°F
ATTACHMENT 2 10 CFR 50.46 "Acceptance criteria for emergency core cooling systems for light-water nuclear power reactors" Annual Report of the Emergency Core Cooling System Evaluation Model Changes and Errors Assessments as of April 7, 2016 Assessment Notes R.E. Ginna Nuclear Power Plant
Annual Report of the Emergency Core Cooling System Evaluation Model Changes and Errors Assessments as of April 7, 2016 Attachment 2 Assessment Notes Page 1 of 2
- 1. Prior LOCA Model Assessment The 10 CFR 50.46 report dated April 30, 2007, reported new licensing basis Peak Cladding Temperature (PCT) for Small Break Loss of Coolant Accident (SBLOCA) and Large Break Loss of Coolant Accident (LBLOCA) analyses to support fuel assembly transition from OFA to 422 Vantage+ and extended power uprate. The new licensing basis PCT reported for SBLOCA and LBLOCA are 1167°F and 1870°F, respectively.
- 2. Prior LOCA Model Assessment The 10 CFR 50.46 report dated May 4, 2008, reported an evaluation for LBLOCA related to HOTSPOT fuel relocation error which resulted in a 37°F PCT assessment.
- 3. Prior LOCA Model Assessment The 10 CFR 50.46 report dated February 10, 2009, reported evaluations for SBLOCA and LBLOCA model changes which resulted in 0°F PCT change.
- 4. Prior LOCA Model Assessment The 10 CFR 50.46 report dated March 26, 2010, reported evaluations for LBLOCA model changes which resulted in 0°F PCT change.
- 5. Prior LOCA Model Assessment The 10 CFR 50.46 report dated March 4, 2011, reported evaluations for SBLOCA and LBLOCA model changes which resulted in 0°F PCT change.
- 6. Prior LOCA Model Assessment The 10 CFR 50.46 report dated March 27, 2012, reported evaluations for SBLOCA and LBLOCA model changes which resulted in 0°F PCT change.
- 7. Prior LOCA Model Assessment The 30-day 10 CFR 50.46 report dated August 16, 2012, reported evaluations for fuel pellet thermal conductivity degradation (TCD) and peaking factor burndown, and design input change assessments which resulted in a 134°F PCT impact for LBLOCA.
- 8. Prior LOCA Model Assessment The 10 CFR 50.46 report dated April 1, 2013, reported evaluations for SBLOCA model changes which resulted in 0°F PCT impact. A LBLOCA assessment for the evaluation of an elevated initial containment and accumulator temperature was submitted in a License Amendment Request for NRC review and approval. The assessment resulted in a 75°F PCT impact. This increase in temperature was approved in an NRC Safety Evaluation Report (SER) (ML14232A331) dated August 21, 2014. The SER (ML14232A331) evaluated the 10 CFR 50.46 reporting criteria explicitly.
Annual Report of the Emergency Core Cooling System Evaluation Model Changes and Errors Assessments as of April 7, 2016 Attachment 2 Assessment Notes Page 2 of 2
- 9. Prior LOCA Model Assessment The 10 CFR 50.46 report dated April 9, 2014, reported evaluations for SBLOCA model changes which resulted in 0°F PCT impact. A LBLOCA assessment was reported related to revised heat transfer multiplier distribution which resulted in a 2°F PCT assessment.
- 10. Prior LOCA Model Assessment The 10 CFR 50.46 report dated April 9, 2015 reported general code maintenance for both LBLOCA and SBLOCA. An error in Decay Group Uncertainty Factors against the LBLOCA model was reported. Additional, it reported errors in Fuel Rod Gap Conductance, Radiation Heat Transfer Model, and SBLOCTA Pre-DNB Cladding Surface Heat Transfer Coefficient Calculation for the SBLOCA model. All changes resulted in 0 °F PCT impact.
Various changes have been made to enhance the usability of codes and to streamline future analyses. Examples of these changes include modifying input variable definitions, units and defaults; improving the input diagnostic checks; enhancing the code output; optimizing active coding; and eliminating inactive coding. These changes resulted in an estimated PCT impact of 0°F. There is no impact to LBLOCA.
Ginna began inserting reconstituted fuel with 5 stainless steel filler rods starting in Cycle 39.
The effects to SBLOCA are 0°F and the effects to LBLOCA are 1°F.
Exelon Generation 200 Exelon Way Kennett Square. PA 19348 www.exeloncorp.com 10 CFR 50.46 April 7, 2016 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-0001 R.E. Ginna Nuclear Power Plant Renewed Facility Operating License No. DPR-18 N RC Docket No. 50-244
Subject:
2016 10 CFR 50.46 Annual Report
Reference:
Letter from J. Barstow (Exelon Generation Company, LLC) to U.S. Nuclear Regulatory Commission, "2015 10 CFR 50.46 Annual Report," dated April 9, 2015 The purpose of this letter is to submit the 10 CFR 50.46 annual reporting information for R.E.
Ginna Nuclear Power Plant. The referenced document is the most recent annual 10 CFR 50.46 Report report submitted to the U.S. Nuclear Regulatory Commission.
Two attachments are included with this letter that provide the current Ginna 10 CFR 50.46 status. Attachment 1 provides the Peak Cladding Temperature (PCT) "rack-up" sheets. , "Assessment Notes," contains a detailed description of each change/error reported.
There are no commitments contained in this letter. If you have any questions, please contact Ron Reynolds at 610-765-5247.
Respectfully, J~:JT j__Jy<--
Director - Licensing & Regulatory Affairs Exelon Generation Company, LLC Attachments: 1) Peak Cladding Temperature Rack-Up Sheet for R.E. Ginna Nuclear Power Plant
- 2) Assessment Notes cc: U.S. NRC Administrator, Region I U.S. NRG Project Manager, Ginna U.S. NRC Senior Resident Inspector, Ginna
ATTACHMENT 1 10 CFR 50.46 "Acceptance criteria for emergency core cooling systems for light-water nuclear power reactors" Annual Report of the Emergency Core Cooling System Evaluation Model Changes and Errors Assessments as of April 7, 2016 Peak Cladding Temperature Rack-Up Sheet for R.E. Ginna Nuclear Power Plant
Annual Report of the Emergency Core Cooling System Evaluation Model Changes and Errors Assessments as of April 7, 2016 Attachment 1 Peak Cladding Temperature Rack-Up Sheet for Ginna Page 1 of 2 PLANT NAME: Ginna ECCS EVALUATION MODEL: Small Break Loss of Coolant Accident (SBLOCA)
REPORT REVISION DATE: 4/7/2016 CURRENT OPERATING CYCLE: 39 ANAL VSIS OF RECORD Evaluation Model: NOTRUMP Calculation: Westinghouse CN-LIS-04-206, April 2005 Fuel: 422 Vantage+
Limiting Fuel Type: 422 Vantage+
Limiting Single Failure: Diesel Generator Failure to Start Limiting Break Size and Location: 2-inch Equivalent High Tavg Cold Leg Break Reference Peak Cladding Temperature (PCT) PCT= 1167 .0°F MARGIN ALLOCATION A. PRIOR LOSS OF COOLANT ACCIDENT (LOCA) MODEL ASSESSMENTS 10 CFR 50.46 report dated April 30, 2007 (Note 1) ~PCT= 0°F 10 CFR 50.46 report dated February 10, 2009 (Note 3) ~PCT= 0°F 10 CFR 50.46 report dated March 4, 2011 (Note 5) ~PCT= 0°F 10 CFR 50.46 report dated March 27, 2012 (Note 6) ~PCT= 0°F 10 CFR 50.46 report dated April 1, 2013 (Note 8) ~PCT= 0°F 10 CFR 50.46 report dated April 9, 2014 (Note 9) ~PCT= 0°F 10 CFR 50.46 report dated April 9, 2015 (Note 1O) ~PCT= 0°F NET PCT PCT =1167.0°F B. CURRENT LOCA MODEL ASSESSMENTS General Code Maintenance (Note 11) ~PCT= 0°F Effects of Fuel Reconstitution (Note 12) ~PCT= 0°F Total PCT change from current assessments L ~PCT= 0°F Cumulative PCT change from current assessments L I ~PCT I= 0°F NET PCT PCT =1167.0°F
Annual Report of the Emergency Core Cooling System Evaluation Model Changes and Errors Assessments as of April 7, 2016 Attachment 1 Peak Cladding Temperature Rack-Up Sheet for Ginna Page 2 of 2 PLANT NAME: Ginna ECCS EVALUATION MODEL: Large Break Loss of Coolant Accident (LBLOCA)
REPORT REVISION DATE: 4/7/2016 CURRENT OPERATING CYCLE: 39 ANALYSIS OF RECORD Evaluation Model: ASTRUM (2004)
Calculation: Westinghouse CN-LIS-05-11, April 2005 Fuel: 422 Vantage+
Limiting Fuel Type: 422 Vantage+
Limiting Single Failure: Loss of one train of ECCS flow Limiting Break Size and Location: Cold Leg Split Break Reference PCT PCT= 1870.0°F MARGIN ALLOCATION A. PRIOR LOSS OF COOLANT ACCIDENT (LOCA) MODEL ASSESSMENTS 1o CFR 50.46 report dated April 30, 2007 (Note 1) dPCT = 0°F 10 CFR 50.46 report dated May 4, 2008 (Note 2) dPCT =+ 37°F 10 CFR 50.46 report dated February 10, 2009 (Note 3) dPCT = 0°F 10 CFR 50.46 report dated March 26, 201 O (Note 4) dPCT = 0°F 10 CFR 50.46 report dated March 4, 2011 (Note 5) dPCT = 0°F 10 CFR 50.46 report dated March 27, 2012 (Note 6) dPCT = 0°F 10 CFR 50.46 report dated August 16, 2012 (Note 7) dPCT = +134°F 10 CFR 50.46 report dated April 1, 2013 (Note 8) dPCT = +75°F 10 CFR 50.46 report dated April 9, 2014 (Note 9) dPCT = +2°F 10 CFR 50.46 report dated April 9, 2015 (Note 10) dPCT = 0°F NET PCT PCT =2118.0°F B. CURRENT LOCA MODEL ASSESSMENTS General Code Maintenance (Note 11) dPCT = 0°F Effects of Fuel Reconstitution (Note 12) dPCT = +1°F Total PCT change from current assessments I dPCT = +1°F Cumulative PCT change from current assessments L IdPCT I= 1°F NET PCT PCT =2119.0°F
ATTACHMENT 2 10 CFR 50.46 "Acceptance criteria for emergency core cooling systems for light-water nuclear power reactors" Annual Report of the Emergency Core Cooling System Evaluation Model Changes and Errors Assessments as of April 7, 2016 Assessment Notes R.E. Ginna Nuclear Power Plant
Annual Report of the Emergency Core Cooling System Evaluation Model Changes and Errors Assessments as of April 7, 2016 Attachment 2 Assessment Notes Page 1 of 2
- 1. Prior LOCA Model Assessment The 10 CFR 50.46 report dated April 30, 2007, reported new licensing basis Peak Cladding Temperature (PCT) for Small Break Loss of Coolant Accident (SBLOCA) and Large Break Loss of Coolant Accident (LBLOCA) analyses to support fuel assembly transition from OFA to 422 Vantage+ and extended power uprate. The new licensing basis PCT reported for SBLOCA and LBLOCA are 1167°F and 1870°F, respectively.
- 2. Prior LOCA Model Assessment The 10 CFR 50.46 report dated May 4, 2008, reported an evaluation for LBLOCA related to HOTSPOT fuel relocation error which resulted in a 37°F PCT assessment.
- 3. Prior LOCA Model Assessment The 10 CFR 50.46 report dated February 10, 2009, reported evaluations for SBLOCA and LBLOCA model changes which resulted in 0°F PCT change.
- 4. Prior LOCA Model Assessment The 10 CFR 50.46 report dated March 26, 2010, reported evaluations for LBLOCA model changes which resulted in 0°F PCT change.
- 5. Prior LOCA Model Assessment The 10 CFR 50.46 report dated March 4, 2011, reported evaluations for SBLOCA and LBLOCA model changes which resulted in 0°F PCT change.
- 6. Prior LOCA Model Assessment The 10 CFR 50.46 report dated March 27, 2012, reported evaluations for SBLOCA and LBLOCA model changes which resulted in 0°F PCT change.
- 7. Prior LOCA Model Assessment The 30-day 10 CFR 50.46 report dated August 16, 2012, reported evaluations for fuel pellet thermal conductivity degradation (TCD) and peaking factor burndown, and design input change assessments which resulted in a 134°F PCT impact for LBLOCA.
- 8. Prior LOCA Model Assessment The 10 CFR 50.46 report dated April 1, 2013, reported evaluations for SBLOCA model changes which resulted in 0°F PCT impact. A LBLOCA assessment for the evaluation of an elevated initial containment and accumulator temperature was submitted in a License Amendment Request for NRC review and approval. The assessment resulted in a 75°F PCT impact. This increase in temperature was approved in an NRC Safety Evaluation Report (SER) (ML14232A331) dated August 21, 2014. The SER (ML14232A331) evaluated the 10 CFR 50.46 reporting criteria explicitly.
Annual Report of the Emergency Core Cooling System Evaluation Model Changes and Errors Assessments as of April 7, 2016 Attachment 2 Assessment Notes Page 2 of 2
- 9. Prior LOCA Model Assessment The 10 CFR 50.46 report dated April 9, 2014, reported evaluations for SBLOCA model changes which resulted in 0°F PCT impact. A LBLOCA assessment was reported related to revised heat transfer multiplier distribution which resulted in a 2°F PCT assessment.
- 10. Prior LOCA Model Assessment The 10 CFR 50.46 report dated April 9, 2015 reported general code maintenance for both LBLOCA and SBLOCA. An error in Decay Group Uncertainty Factors against the LBLOCA model was reported. Additional, it reported errors in Fuel Rod Gap Conductance, Radiation Heat Transfer Model, and SBLOCTA Pre-DNB Cladding Surface Heat Transfer Coefficient Calculation for the SBLOCA model. All changes resulted in 0 °F PCT impact.
Various changes have been made to enhance the usability of codes and to streamline future analyses. Examples of these changes include modifying input variable definitions, units and defaults; improving the input diagnostic checks; enhancing the code output; optimizing active coding; and eliminating inactive coding. These changes resulted in an estimated PCT impact of 0°F. There is no impact to LBLOCA.
Ginna began inserting reconstituted fuel with 5 stainless steel filler rods starting in Cycle 39.
The effects to SBLOCA are 0°F and the effects to LBLOCA are 1°F.