ML15194A015, Final Determination of Licensee Seismic Probabilistic Risk Assessments

From kanterella
Jump to navigation Jump to search

Final Determination of Licensee Seismic Probabilistic Risk Assessments

October 27, 2015

ML15194A015

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 The Power Reactor Licensees on the Enclosed List SUBJECT: FINAL DETERMINATION OF LICENSEE SEISMIC PROBABILISTIC RISK ASSESSMENTS UNDER THE REQUEST FOR INFORMATION PURSUANT TO TITLE 10 OF THE CODE OF FEDERAL REGULATIONS 50.54(f) REGARDING RECOMMENDATION 2.1 "SEISMIC" OF THE NEAR-TERM TASK FORCE REVIEW OF INSIGHTS FROM THE FUKUSHIMA DAl-ICHI ACCIDENT

The U.S. Nuclear Regulatory Commission (NRC) is issuing this letter to (1) inform power reactor licensees of the remaining seismic evaluations[1] that each licensee will perform, (2) inform those licensees that will perform a seismic probabilistic risk assessment (SPRA), and (3) establish the associated due dates for the seismic evaluations and SPRAs to complete licensees' responses to the March 12, 2012, request for information[2]. By letters[3] dated May 9, 2014,4 and May 13, 2015[4], the NRC informed licensees of the initial screening and prioritization results, indicating that 33 power reactor sites would perform SPRAs[5] because their reevaluated hazard exceeds their current design-basis. The NRC staff has completed an assessment of reevaluated hazard and available seismic risk information and has concluded that 13 sites with low to moderate reevaluated seismic hazard exceedance above their current design-basis are no longer expected to perform a SPRA. For the remaining 20 sites, SPRAs continue to be the appropriate analyses to assess the total plant response to the reevaluated hazard, so as to inform the NRC's regulatory decisions on the adequacy of these sites' current seismic design-basis. For these 20 sites, the NRC staff revised the schedule for submitting the SPRAs to more effectively align the submittal dates with available NRC and industry resources. The revised schedule expedites the industry's completion of the SPRAs to December 2019, one year ahead of the original schedule, while staggering the submittals to allow for additional time for some sites to enable thorough evaluations. The NRC staff continues to have reasonable assurance that plants can operate safely while these risk evaluations are completed.

Enclosure 1 to this letter lists the SPRA submittal dates for the sites that will submit a SPRA. In addition to SPRAs, the enclosure outlines the remaining seismic evaluations (i.e., high frequency (HF), low frequency, spent fuel pool (SFP), and individual plant examination of external events (IPEEE)-associated evaluations) for plant structures, systems, and components that each licensee will complete to conclude its response to the March 12, 2012, request for information.

The information and the associated schedule for submittal of the mitigation strategies assessment reflecting the reevaluated seismic hazard will be addressed in subsequent correspondence.

BACKGROUND

On March 12, 2012, the NRC issued a request for information pursuant to Title 10 of the Code of Federal Regulations (1 O CFR) Part 50, Section 50.54(f) (hereafter referred to as the 50.54(f) letter). One purpose of that request was to gather information concerning the reevaluated seismic hazards at operating reactor and construction permit sites to enable the NRC staff to determine whether licenses should be modified, suspended, or revoked. The "Required Response" section of Enclosure 1 of the 50.54(f) letter indicated that licensees and construction permit holders should provide seismic hazard evaluation using present-day methods. Enclosure 3 of this letter lists the reevaluated seismic hazard and screening reports (SHSR) provided by each of the licensees. The NRC staff has reviewed each of the SHSRs and is in the process of documenting each review. The 50.54(f) letter stated that the NRC would provide the results of the screening and prioritization indicating deadlines for individual plants to complete SPRAs, if necessary, to assess the total plant response to the reevaluated seismic hazard.

By letters dated May 9, 2014, and May 13, 2015, the NRC informed licensees of operating reactors and construction permit holders of the initial screening and prioritization results, as described in Enclosure 1 of the 50.54(f) letter. The letters also discussed that the NRC would determine which plants will complete a SPRA to support NRC regulatory decision-making. The NRC initially screened plants consistent with the industry developed and the NRC endorsed "Seismic Evaluation Guidance: Screening, Prioritization and Implementation Details [SPID] for the Resolution of Fukushima Near-Term Task Force [NTTF] Recommendation 2.1: Seismic" [6] (ADAMS Accession No. ML12333A170). The SPID guidance established the evaluations that would be requested by the NRC. This was determined by considering the difference in the plant's design-basis safe shutdown earthquake (SSE) or IPEEE capacity spectrum and the reevaluated seismic hazard (ground motion response spectrum (GMRS)). The initial screening approach is discussed in greater detail in the SPID guidance and in prior screening letters. In light of improved understanding of the reevaluated hazards, as well as consideration of available risk insights, the staff has reassessed the need and scope of additional seismic evaluations for some plants. The reassessment approach and results are discussed below.

FINAL DETERMINATION FOR SEISMIC PROBABILISTIC RISK ASSESSMENTS

The initial screening documented in the May 9, 2014, and May 13, 2015, letters, categorized 33 sites as needing to submit a SPRA. Following the initial screening, the NRC staff performed an additional assessment, examining available information to determine the need for these plants to perform a SPRA. For each plant, the NRC staff assessed if the reevaluated seismic hazard creates a significantly higher seismic demand, such that a SPRA is necessary to inform the NRC's decision described in the 50.54(f) letter.

The first consideration focused on the change in seismic hazard. Specifically, the amount by which the GMRS exceeds the SSE in the 1-10 Hertz (Hz) frequency range and the peak of the spectral acceleration in the 1-10 Hz frequency range were considered. If the GMRS exceedance and/or peak spectral acceleration were considered significant, then the NRC staff concluded that a SPRA continues to be necessary for that site.

If the first consideration was judged as not significant, then the second of the two considerations focused on a general estimation of the plant's seismic core damage frequency (SCDF) and on insights related to the conditional containment failure probability for that plant's specific type of containment. As with the first consideration, if the estimated SCDF was considered significant and/or if there were potential implications in the context of the containment type, then the NRC staff concluded that a SPRA evaluation continues to be the appropriate approach.

If the seismic hazard exceedance, peak of the spectral acceleration, and the general estimation of the SCDF were judged to be not significant, then the NRC staff concluded that a SPRA is not necessary for NRC's 50.54(f) letter-related regulatory decisions. Based on this additional assessment, the NRC staff has determined that SPRA are not warranted for 13 sites listed in Table 1 a in Enclosure 1.

For the remaining 20 sites, SPRAs continue to be the appropriate analysis to assess the total plant response to the reevaluated hazard so as to inform the NRC's regulatory decisions on the adequacy of these sites' current seismic design-basis. Table 1 a in Enclosure 1, lists the SPRA submittal dates for the sites that will be submitting a SPRA. In addition for all sites, Tables 1 a and 1b outline the remaining seismic evaluations (i.e., high frequency, low frequency, SFP, and IPEEE-associated evaluations) for plant system, structures, and components that will be submitted by each licensee to complete its response to the March 12, 2012, request for information.

NEXT STEPS FOR COMPLETION OF RECOMMENDATION 2.1 SEISMIC ACTIVITIES SPRA SUBMITTAL SCHEDULES

Licensees are now expected to provide their SPRA by the dates indicated in Enclosure 1 to this letter. The established dates are consistent with those discussed during a public meeting[7] held on September 3, 2015. The NRC staggered the schedule for the SPRA submittals to align with the availability of NRC and industry resources. The schedule revisions support earlier submittal of SPRAs by March 2017, three months sooner than the previous date for the first submittals, and support the last submittal being no later than December 31, 2019, which is one year sooner than the previous date. The revised schedules will also allow for additional time for some sites to enable a thorough evaluation. The NRC continues to have reasonable assurance that plants can operate safely while these risk evaluations are completed.

Licensees that are expected to submit a SPRA, should use the reevaluated seismic hazard already reviewed by the NRC staff. The NRC does not plan to re-review the reevaluated seismic hazard as part its review of the SPRA, unless a licensee has used a new or updated reevaluated seismic hazard that has not been reviewed by the NRC staff. Consistent with the letter dated December 10, 2014 (ADAMS Accession No. ML14307B707}, licensees are encouraged to inform the NRC of planned changes to the reevaluated seismic hazard to support development of NRC review plans.

LIMITED SCOPE EVALUATION SUBMITTAL SCHEDULES

As indicated above, Tables 1 a and 1 b outline the limited scope evaluations remaining to be submitted by licensees. As part of the seismic hazard reevaluation activities described in the SPID, the detailed implementation guidance for the limited scope evaluations continues to be under development. Once the implementing guidance is finalized, licensees are encouraged to use the guidance in preparing their limited scope evaluations. The Nuclear Energy Institute (NEI) proposed a schedule for the submittal of HF evaluations by letter dated July 30, 2015 (ADAMS Accession No. ML15223A095), and for the SFP evaluations in the September 3, 2015, public meeting. The NRC staff accepts these submitted schedules, but the NRC acknowledges that further prioritization and refinements to NTTF Recommendation 2.1 Seismic submittal schedules may occur to accommodate the proposed mitigation strategies assessments for the reevaluated hazard identified in draft regulatory guide DG-1301, "Flexible Mitigation Strategies for Beyond-Design-Basis Events," supporting SECY 15-0065, "Proposed Rule: Mitigation of Beyond-Design-Basis Events."

As a result of NRC staff efforts to conduct efficient reviews, HF and SFP evaluation submittals fall into two tiers based on hazard exceedance above the design-basis or peak spectral acceleration. For HF evaluations, licensees with limited exceedance above plant design bases, submittals are expected by December 31, 2015. For remaining licensees conducting a HF evaluation, submittals are expected by December 31, 2016. Further, for those sites where SPRA evaluations are no longer expected, HF evaluations submittals are expected by August 31, 2017. For licensees who are completing a SPRA, HF component performance will be assessed as part of the SPRA submittal. Separately, licensees requested to complete lowfrequency evaluations should submit the evaluation no later than December 2016.

For SFP evaluations, sites are divided between low to moderate GMRS sites (i.e., peak spectral acceleration less than 0.8g for this application) and those with higher peak spectral acceleration.

Sites with lower peak spectral acceleration are projected to submit their evaluations by December 31, 2016. Those with higher peak spectral acceleration are expected to complete SFP evaluations by December 31, 2017.

The NRC will continue to work with licensees and other external stakeholders to schedule limited scope evaluation submittals commensurate with safety significance and the availability of NRC and industry resources.

OPTIONS FOR SUBMITTAL OF REMAINING IPEEE SCREENING EVALUATIONS

As indicated in Tables 1 a and 1 b in Enclosure 1 to this letter, several licensees demonstrated that IPEEE capacity spectra are a suitable comparison to the GMRS to screen out of performing a SPRA. These plants are expected to complete additional HF and SFP evaluations, consistent with the IPEEE acceptance criteria in the SPID. The plants listed in Table 1 b have a moderate high frequency exceedance compared to the SSE. Table 1 b includes a subset of four sites listed in Table 1 a and outlines two options to respond to the remaining information requests associated with the 50.54(f) letter. Option 1 relies on the IPEEE submittal and would need a relay chatter evaluation as indicated by the IPEEE criteria in the SPID guidance. Consistent with NEI letter dated July 30, 2015, submittal of IPEEE relay chatter evaluation is due December 31, 2016. Option 2 allows for completion using the HF evaluation approach. In choosing one of the two options, these licensees should consider that a relay chatter study will continue to be needed for the IPEEE submittal to meet the SPID acceptance criteria. Meeting the SPID criteria will be necessary if a licensee plans to rely on the IPEEE results in its mitigation strategies assessment with respect to the reevaluated hazard.

If you have any questions regarding this letter, please contact Nicholas DiFrancesco at 301-415-1115 or via email at Nicholas.Difrancesco@nrc.gov.

Enclosures:

1. Recommendation 2.1 Seismic - Information Request Tables

2. Glossary of Recommendation

2.1 Seismic Evaluations

3. Seismic Hazard Submittals and Prior Screening Letters 4. List of Licensees cc: Listserv Sincerely, ~ William M. Dean, Director Office of Nuclear Reactor Regulation Table 1 a. Recommendation 2.1 Seismic - Information Requests1 IPEEE Seismic Limited-Scope Evaluations Screening Probabilistic Evaluation Risk N Plant Name >. >. O.> Assessment (.) (.) ::J .....

..c c s: ~ u.. - >. O.> Submittal O> O.> 0 rn ~ 0 ::J -o - rn ·- ::J ~c.. O.> ..c Date2 · 3 I O" ....J O" O.> 0::: u .O....>. ..... c.

u.. u.. Cf) Arkansas Nuclear One, Units 1 and 2 x x Beaver Valley Power Station, Units 1 and 2 9/30/17 x Bellefonte Nuclear Plant, Units 1 and 2 Footnote 4 x Braidwood Station, Units 1 and 2 x Browns Ferry Nuclear Plant, Units 1, 2, and 3 12/31/19 x Brunswick Steam Electric Plant, Units 1 and 2 x x x Byron Station, Units 1 and 2 See Table 1b.

Callaway Plant, Unit 1 12/31/17 x Calvert Cliffs Nuclear Power Plant, Units 1 and 2 x x Catawba Nuclear Station, Units 1 and 2 9/30/19 x Clinton Power Station, Unit No. 1 x Columbia Generating Station 3/31/19 x Comanche Peak Nuclear Power Plant, Units 1 and 2 Cooper Nuclear Station x x 1 This table identifies the SPRA submittal dates for applicable sites. The table also identifies the remaining information to be submitted by licensees to complete the response to the 50.54(f) letter.

2 The SPRAs will assess the effects of high frequency exceedance on plant equipment.

3 SPRAs or SMAs are no longer expected for Calvert Cliffs Nuclear Power Plant, Units 1 and 2, Cooper Nuclear Station, Davis-Besse Nuclear Power Station, Unit 1, Edwin I. Hatch Nuclear Plant, Units 1 and 2, Fermi, Unit 2, LaSalle County Station, Units 1 and 2, Monticello Nuclear Generating Plant, Oyster Creek Nuclear Generating Station, Point Beach Nuclear Plant, Units 1 and 2, Perry Nuclear Power Plant, Unit 1, Seabrook, Unit 1, Three Mile Island Nuclear Station, Unit 1, and Wolf Creek Generating Station, Unit 1.

4 By letter dated February 26, 2015, the NRC accepted an alternative submittal schedule due to deferred construction status.

Enclosure 1 - 2 - Table 1a. Recommendation 2.1 Seismic- Information Requests1 IPEEE Seismic Limited-Scope Evaluations Screening Probabilistic Evaluation Risk N Plant Name >. >. Q) Assessment u u :J ,,_ ..r::. c ~ l5 LL - >. Q) Submittal O> Q) 0 co ::::::

·- :J 0 :J _l5. 0 - co (L Q) ..r::.

Date2 · 3 I c- _J 0- Q) Q) ,,_ ,,_ 0. 0::: u LL LL CJ) Davis-Besse Nuclear Power Station, Unit 1 x x Diablo Canyon Power Plant, Unit Nos. 1 and 2 9/30/17 x Donald C. Cook Nuclear Plant, Units 1 and 2 6/30/18 x Dresden Nuclear Power Station, Units 2 and 3 6/30/19 x Duane Arnold Enerav Center x Edwin I. Hatch Nuclear Plant, Units 1 and 2 x x x Fermi, Unit 2 x x Fort Calhoun Station, Unit 1 x x Grand Gulf Nuclear Station, Unit 1 H. B Robinson Steam Electric Plant, Unit No. 2 3/31/19 x Hope Creek Generating Station xs Indian Point Nuclear Generating, Unit No. 2 6/30/17 x Indian Point Nuclear Generating, Unit No. 3 6/30/18 x James A. FitzPatrick Nuclear Power Plant See Table 1 b.

Joseph M. Farley Nuclear Plant, Units 1 and 2 Footnote 6 Footnote 6 LaSalle County Station, Units 1 and 2 x x Limerick Generating Station, Units 1 and 2 x McGuire Nuclear Station, Units 1 and 2 12/31/19 x Millstone Power Station, Units 2 and 3 See Table 1 b.

Monticello Nuclear Generating Plant x x 5 By letter dated March 28, 2014, the licensee committed to complete an IPEEE relay review in lieu of a high frequency confirmation.

6 Evaluation no longer expected based on de minimis exceedance above the design-basis SSE.

- 3 - Table 1a. Recommendation 2.1 Seismic - Information Reauests1 IPEEE Seismic Limited-Scope Evaluations Screening Probabilistic Evaluation Risk N Plant Name >. >. Q) Assessment u u :::J ,_ ..c c $: ~ u. - >. Q) Submittal O> Q) 0 ca :::::

0 :::J _. 0 - ca ·- :::J ~o.. Q) ..c Date2·3 I c- __J C'" Q) Q) 0.. ,_ ,_ 0::: () u. u. CJ) Nine Mile Point Nuclear Station, Units 1 and 2 x North Anna Power Station, Units 1 and 2 3/31/18 x Oconee Nuclear Station, Units 1, 2, and 3 12/31/18 x Ovster Creek Nuclear Generating Station x x Palisades Nuclear Plant 9/30/19 x Palo Verde Nuclear GeneratinQ Station, Units 1, 2, and 3 Peach Bottom Atomic Power Station, Units 2 and 3 3/31/18 x Perrv Nuclear Power Plant, Unit 1 x x Pilarim Nuclear Power Station 12/31/17 x Point Beach Nuclear Plant, Units 1 and 2 x x Prairie Island Nuclear Generatino Plant, Units 1 and 2 Footnote 7 Quad Cities Nuclear Power Station, Units 1 and 2 x R. E. Ginna Nuclear Power Plant x River Bend Station, Unit 1 x Salem Nuclear Generating Station, Units 1 and 2 See Table 1 b.

Seabrook Station, Unit No. 1 x x Seauovah Nuclear Plant, Units 1 and 2 12/31/19 x Shearon Harris Nuclear Power Plant, Unit 1 x South Texas Project, Units 1 and 2 St. Lucie Plant, Units 1 and 2 7 Evaluation no longer expected based on NRC acceptance of licensee seismic hazard.

- 4 - Table 1a. Recommendation 2.1 Seismic - Information Requests1 IPEEE Seismic Limited-Scope Evaluations Screening Probabilistic Evaluation Risk N Plant Name >. >. a.> Assessment 0 0 ::J .... - c ~ ~ LL - >. a.> Submittal -§, a.> 0 co :::::

·- ::J 0 ::J - 0 - co Date2 · 3 I o- _J O" ~a.. a.> .c a.> a.> 0.. .... .... 0::: () LL LL Cf) Surry Power Station, Unit Nos. 1 and 2 Footnote 8 Susquehanna Steam Electric Station, Units 1 and 2 x x Three Mile Island Nuclear Station, Unit 1 x x Turkey Point, Units 3 and 4 Virgil C. Summer Nuclear Station, Unit 1 9/30/18 x Vogtle Electric Generating Plant, Units 1 and 2 3/31/17 x Waterford Steam Electric Station, Unit 3 x Watts Bar Nuclear Plant, Units 1 and 2 6/30/17 x Wolf Creek Generating Station, Unit 1 x x 8 Evaluation no longer expected based on de minimis exceedance above design-basis SSE_ - 5 - Table 1 b. Recommendation 2.1 Seismic - Information Requests Options for remaining IPEEE Screening Evaluations1 IPEEE Seismic Limited-Scope Evaluations Screening Probabilistic Evaluation Plant Name Risk >- >- 0 Assessment 0 0 I-..c c 3: ~ - 0 >- Submittal 0) ~ 0... ro ~ ·I - :e:Jr 0 ::J c.- - .r.oc .....J er Date Cf) ~ 0::: () uI-. uI-. u.

Option 1 x x x Byron Station, Units 1 and 2 or Option 2 x x Option 1 x x James A. FitzPatrick Nuclear Power Plant or Option 2 x x Option 1 x x x Millstone Power Station, Units 2 and 3 or Option 2 x x Option 1 x x Salem Nuclear Generating Station, Units 1 and 2 or Option 2 x x 1 This table outlines two options for licensees to respond to the remaining information requests associated with high frequency exceedance as part of the 50.54(f) letter. The high frequency evaluation and IPEEE relay review differ in scope of equipment and evaluation approach. Both approaches are acceptable to assessing plant performance for high frequency exceedance dependent on site screening. For additional background, the high frequency evaluation approach is discussed in the Nuclear Energy Institute letter dated July 30, 2015, and the IPEEE relay review is discussed in Section 3.4 of the industry-issued SPID guidance dated November 16, 2012.

In choosing one of the two options, these licensees should consider that a relay chatter study will continue to be needed for the IPEEE submittal to meet the SPID acceptance criteria. Meeting the SPID criteria will be necessary if a licensee plans to rely on the IPEEE results in its mitigation strategies assessment with respect to the reevaluated hazard.

Glossary of Evaluations Associated with Near-Term Task Force Recommendation 2.1 Seismic Evaluations Interim Evaluation or Actions - An immediate licensee and NRC review of the reevaluated hazard to determine whether actions are needed to assure plant safety while further evaluations are ongoing. The NRC staff completed its review and concluded that, based on the licensees' interim evaluations and actions, Central and Eastern United States (CEUS}, as well as Western United States (WUS) plants are safe for continued operations, while more detailed evaluations are on-going. Interim evaluations and actions are provided in Section 5.0, "Interim Actions," of the licensees' seismic hazard reevaluation and screening report submittals.

Expedited Approach -A near-term licensee evaluation completed in December 2014 for CEUS plants and by January 31, 2016, for WUS plants whose reevaluated hazard exceeds the current design-basis for the safe shutdown earthquake hazard level. The evaluation looked at certain key pieces of equipment that can be used to provide core cooling under the conditions of a station blackout (i.e., no alternating current power is available) and loss of ultimate heat sink for a seismic hazard up to two times the safe shutdown earthquake.

Seismic Probabilistic Risk Assessment - The seismic probabilistic risk assessment provides comprehensive plant seismic capacity information to make regulatory decisions, such as whether to amend a plant's design or licensing basis or make additional safety enhancements.

These evaluations provide information to make risk-informed decisions. The NRC staff will use this information in conjunction with the existing regulatory tools, such as backfit analysis, to decide on further regulatory actions.

Limited-Scope Evaluations - These include i) Spent Fuel Pool Evaluation, ii) High Frequency Evaluation, and iii) Low Frequency Evaluation. Respectively, these evaluations are focused on the following: i) spent fuel pool structure and cooling components and systems that influence the water inventory for cooling the spent fuel, ii) a review of components susceptible to high frequency accelerations (e.g., electrical relays) to ensure maintenance of certain key functions, and iii) a review of select components susceptible to low frequency accelerations (e.g., water storage tanks).

Relay Chatter Evaluation - The individual plant examination for external events (IPEEE) seismic risk evaluations included a number of different approaches, such as seismic probabilistic risk assessment, reduced-scope seismic margin analysis (SMA}, focused-scope SMA, and full-scope SMA. For licensees that used their IPEEE results for screening considerations, but for which their IPEEE was a focused-scope SMA, the licensee needs to enhance their relay chatter evaluations to be comparable to the evaluations performed for full-scope SMAs. The relay chatter evaluation needs to be a full-scope review for components, such as electric relays and switches.

Enclosure 2 Seismic Hazard Submittals and Prior Screening Letters Licensee Facility Seismic Hazard and Screening Report Prior Screening Letter(s) and Supplements (ADAMS Accession Nos.) (ADAMS Accession Nos.) Arkansas Nuclear One, Units 1 and 2 March 28, 2014(ML14092A021), and May 9, 2014(ML14111A147), and August 21, 2014(ML14233A275) November 21, 2014(ML14246A428) March 31, 2014(ML14090A143), and May 9, 2014(ML14111A147) Beaver Valley Power Station, Units 1 and 2 June 29, 2015(ML15181A085) March 31, 2014(ML14098A478), May 9, 2014(ML14111A147), and Bellefonte Nuclear Plant, Units 1 and 2 October 21, 2014(ML14295A290), February 26, 2015 (ML 15023A259) and December 3, 2014 (ML 14338A787) Braidwood Station, Units 1 and 2 March 31, 2014(ML14091A243) May 9, 2014(ML14111A147) Browns Ferry Nuclear Plant, Units 1, 2, and 3 March 31, 2014(ML14098A478) May 9, 2014(ML14111A147) Brunswick Steam Electric Plant, Units 1 and 2 March 31, 2014 (ML14106A461), and May 9, 2014(ML14111A147), and August 14, 2014(ML14241A432) September 17, 2014(ML14231A964) Byron Station, Units 1 and 2 March 31, 2014 (ML14091A010) May 9, 2014(ML14111A147) Callaway Plant, Unit 1 March 28, 2014(ML14090A446) May 9, 2014(ML14111A147) Calvert Cliffs Nuclear Power Plant, Units 1 and 2 March 31, 2014 (ML14099A196) May 9, 2014(ML14111A 147) Catawba Nuclear Station, Units 1 and 2 March 31, 2014 (ML14099A184) and May 9, 2014(ML14111A147) January 8, 2015 (ML 15009A257) Clinton Power Station, Unit 1 March 31, 2014(ML14091A011 ), and May 9, 2014(ML14111A147), and August 21, 2014(ML14234A124) October 3, 2014(ML14258A043) Columbia Generating Station March 12, 2015(ML15078A243), and May 13, 2015(ML151138344) September 24, 2015 (ML 15267 A780) Comanche Peak Nuclear Power Plant, Units 1 March 27, 2014(ML14099A197) May 9, 2014(ML14111A147) and 2 Enclosure 3 - 2 - Seismic Hazard Submittals and Prior Screening Letters Licensee Facility Seismic Hazard and Screening Report Prior Screening Letter(s) and Supplements (ADAMS Accession Nos.) (ADAMS Accession Nos.) Cooper Nuclear Station March 31, 2014(ML14094A048), May 9, 2014(ML14111A147) and February 11, 2015 (ML 15050A 165), October 28, 2014(ML14273A259) and June 22, 2015(ML15177A097) Davis-Besse Nuclear Power Station, Unit 1 March 31, 2014(ML14090A143) May 9, 2014(ML14111A147) March 11, 2015(ML15071A046), May 13, 2015(ML151138344) and Diablo Canyon Power Plant, Unit Nos. 1 and 2 August 12, 2015 (ML 152248575), and July 14, 2015(ML15173A428) September 16, 2015(ML15259A600) Donald C. Cook Nuclear Plant, Units 1 and 2 March 27, 2014(ML14092A327) and May 9, 2014(ML14111A147) November 21, 2014(ML14329A713) Dresden Nuclear Power Station, Units 2 and 3 March 31, 2014(ML14091A012), and May 9, 2014(ML14111A147) July 22, 2015 (ML 15204A088) Duane Arnold Energy Center March 28, 2014(ML14092A331) and May 9, 2014(ML14111A147) and August 21, 2014(ML14198A070) Edwin I. Hatch Nuclear Plant, Units 1 and 2 March 31, 2014(ML14092A017), May 9, 2014(ML14111A147) January 20, 2015 (ML 15020A728), and August 10, 2015(ML15233A074) Fermi, Unit 2 March 31, 2014(ML14090A326), May 9, 2014(ML14111A147) December 18, 2014(ML14353A149), and June 4, 2015(ML151558634) Fort Calhoun Station, Unit 1 March 31, 2014 (ML14097A087), and May 9, 2014(ML14111A147), and July 25, 2014(ML142068064) September 22, 2014(ML14224A526) Grand Gulf Nuclear Station, Unit 1 March 31, 2014(ML14090A098) May 9, 2014(ML14111A147) March 31, 2014(ML14099A204), May 9, 2014(ML14111A147) November 12, 2014(ML14325A645), H. B Robinson Steam Electric Plant, Unit No. 2 April 29, 2015(ML15132A127), July 17, 2015(ML15201A006), and August 29, 2015 (ML 15243A061) Seismic Hazard Submittals and Prior Screening Letters Licensee Facility Seismic Hazard and Screening Report Prior Screening Letter(s) and Supplements (ADAMS Accession Nos.) (ADAMS Accession Nos.) Hope Creek Generating Station March 28, 2014(ML14087A436) May 9, 2014(ML14111A147) March 31, 2014 (ML14099A110), May 9, 2014(ML14111A147) and March 31, 2014 (ML14099A111), November 21, 2014(ML14246A428) Indian Point Nuclear Generating Unit Nos. 2 and 3 August 18, 2014(ML14241A026), and November 5, 2014(ML14310A666) March 31, 2014(ML14090A243), May 9, 2014(ML14111A147) and James A. FitzPatrick Nuclear Power Plant August 21, 2014(ML14237A097), and December 31, 2014(ML14323A027) December 5, 2014(ML14339A773) Joseph M. Farley Nuclear Plant, Units 1 and 2 March 31, 2014(ML14092A020) May 9, 2014(ML14111A147) LaSalle County Station, Units 1 and 2 March 31, 2014(ML14091A013) and May 9, 2014(ML14111A147) July 22, 2015 (ML 15204A088) Limerick Generating Station, Units 1 and 2 March 31, 2014(ML14090A236) and May 9, 2014(ML14111A147) and August 21, 2014(ML14234A 124) October 3, 2014(ML14258A043) McGuire Nuclear Station, Units 1 and 2 March 20, 2014(ML14098A421) May 9, 2014(ML14111A147) Millstone Power Station, Units 2 and 3 March 31, 2014(ML14092A417) May 9, 2014(ML14111A147) and July 21, 2014(ML14204A620) November 21, 2014(ML14246A428) Monticello Nuclear Generating Plant March 31, 2014(ML14090A297), May 9, 2014(ML14111A147) and April 3, 2014(ML140938361), and August 20, 2014(ML14210A030) May 14, 2014(ML14136A285) Nine Mile Point Nuclear Station, Units 1 and 2 March 31, 2014(ML14099A196) May 9, 2014(ML14111A147) North Anna Power Station, Units 1 and 2 March 31, 2014(ML14092A416) May 9, 2014(ML14111A147) March 31, 2014(ML14092A024), May 9, 2014(ML14111A147) Oconee Nuclear Station, Units 1, 2, and 3 November 14, 2014(ML14325A584), and April 30, 2015 (ML 15128A332) Oyster Creek Nuclear Generating Station March 31, 2014 (ML 14090A241) and May 9, 2014(ML14111A147) and August 21, 2014(ML14234A124) November 28, 2014(ML14307A638) - 4 - Seismic Hazard Submittals and Prior Screening Letters Licensee Facility Seismic Hazard and Screening Report Prior Screening Letter(s) and Supplements (ADAMS Accession Nos.) (ADAMS Accession Nos.) Palisades Nuclear Plant March 31, 2014(ML14090A069) May 9, 2014(ML14111A147) Palo Verde Nuclear Generating Station, Units 1, March 10, 2015, (ML 15076A073), May 13, 2015 (ML 15113B344) 2, and 3 April 10, 2015(ML15105A076), and August 6, 2015 (ML 15223A206) Peach Bottom Atomic Power Station Units 2 and March 31, 2014(ML14090A247) May 9, 2014(ML14111A147) 3 Perry Nuclear Power Plant, Unit 1 March 31, 2014(ML14090A143) May 9, 2014(ML14111A147) Pilgrim Nuclear Power Station, Unit No. 1 March 31, 2014(ML14092A023) May 9, 2014(ML14111A147) Point Beach Nuclear Plant, Units 1 and 2 March 31, 2014(ML14090A275) May 9, 2014(ML14111A147) Prairie Island Nuclear Generating Plant, Units 1 March 27, 2014(ML14086A628) May 9, 2014(ML14111A147) and 2 March 31, 2014(ML14090A526), May 9, 2014(ML14111A147) and Quad Cities Nuclear Power Station, Units 1 and 2 June 6, 2014(ML14157A389), and October 3, 2014(ML14258A043) August 21, 2014(ML14234A124) R.E. Ginna Nuclear Power Plant March 31, 2014(ML14099A196) May 9, 2014(ML14111A147) River Bend Station March 26, 2014(ML14091A426) May 9, 2014(ML14111A147) Salem Nuclear Generating Station, Units 1 and 2 March 31, 2014(ML14090A043) May 9, 2014(ML14111A147) and October 3, 2014(ML14258A043) Seabrook, Unit 1 March 27, 2014(ML14092A413) May 9, 2014(ML14111A147) Sequoyah Nuclear Plant, Units 1 and 2 March 31, 2014(ML14098A478) May 9, 2014(ML14111A147) Shearon Harris Nuclear Power Plant, Unit 1 March 27, 2014(ML14090A441) May 9, 2014(ML14111A147) South Texas Project, Units 1 and 2 March 31, 2014(ML14099A235) May 9, 2014(ML14111A147) St. Lucie Plant, Units 1 and 2 March 31, 2014 (ML 14099A 106) May 9, 2014(ML14111A147) Surry Power Station, Unit Nos. 1 and 2 March 31, 2014 (ML 14092A414) May 9, 2014(ML14111A147) and October 3, 2014(ML14258A043) Seismic Hazard Submittals and Prior Screening Letters Licensee Facility Seismic Hazard and Screening Report Prior Screening Letter(s) and Supplements (ADAMS Accession Nos.) (ADAMS Accession Nos.) Susquehanna Steam Electric Station, Units 1 and March 26, 2014(ML14086A163) May 9, 2014(ML14111A147) 2 Three Mile Island Nuclear Station, Unit 1 March 31, 2014 (ML14090A271) May 9, 2014(ML14111A147) Turkey Point, Units 3 and 4 March 27, 2014(ML14106A032) May 9, 2014(ML14111A147) March 26, 2014(ML14092A250), May 9, 2014(ML14111A147) Virgil C. Summer Nuclear Station, Unit 1 November 12, 2014(ML14318A314), and April 28, 2015 (ML 15124A596) Vogtle Electric Generating Plant, Units 1 and 2 March 31, 2014(ML14092A019) May 9, 2014(ML14111A147) Waterford Steam Electric Station, Unit 3 March 27, 2014(ML14086A427) May 9, 2014(ML14111A147) Watts Bar Nuclear Plant, Units 1 and 2 March 31, 2014(ML14098A478) May 9, 2014(ML14111A147) Wolf Creek Generating Station, Unit 1 March 31, 2014 (ML 14097 A020) May 9, 2014(ML14111A147)

LIST OF APPLICABLE POWER REACTOR LICENSEES

Arkansas Nuclear One Entergy Operations, Inc.

Docket Nos. 50-513 and 50-368 License Nos. DPR-51 and NPF-6 Vice President. Operations Arkansas Nuclear One Entergy Operations, Inc.

1448 S.R. 333 Russellville, AR 72802 Beaver Valley Power Station First Energy Nuclear Operating Co.

Docket Nos. 50-334 and 50-412 License Nos. DPR-66 and NPF-73 Mr. Eric A Larson Site Vice President Beaver Valley Power Station P.O. Box 4, Route 168 Shippingport, PA 15077 Bellefonte Nuclear Plant Tennessee Valley Authority Docket Nos. 50-438 and 50-439 Construction Permit Nos. CPPR No. 122 and CPPR No. 123 Mr. Joseph W. Shea Vice President, Nuclear Licensing Tennessee Valley Authority 1101 Market Street, LP 3D-C Chattanooga, TN 37402 Braidwood Station Exelon Generation Co., LLC Docket Nos. 50-456 and 50-457 License Nos. NPF-72 and NPF-77 Mr. Bryan C. Hanson Senior Vice President Exelon Generation Company, LLC President and Chief Nuclear Officer Exelon Nuclear 4300 Winfield Road Warrenville, IL 60555 Browns Ferry Nuclear Plant Tennessee Valley Authority Docket Nos. 50-259, 50-260 and 50-296 License Nos. DPR-33, DPR-52 and DPR-68 Mr. Joseph W. Shea Vice President, Nuclear Licensing Tennessee Valley Authority 1101 Market Street, LP 3D-C Chattanooga, TN 37 402-2801 Byron Station Exelon Generation Co., LLC Docket Nos. STN 50-454 and STN 50-455 License Nos. NPF-37 and NPF-66 Mr. Bryan C. Hanson Senior Vice President Exelon Generation Company, LLC President and Chief Nuclear Officer Exelon Nuclear 4300 Winfield Road Warrenville, IL 60555 Callaway Plant Union Electric Company Docket No. 50-483 License No. NPF-30 Enclosure 4 Mr. Fadi Diya Senior Vice President and Chief Nuclear Officer Ameren Missouri Callaway Plant P.O. Box 620 Fulton, MO 65251 - 2 - Calvert Cliffs Nuclear Power Plant Calvert Cliffs Nuclear Power Plant, LLC Docket Nos. 50-317 and 50-318 License Nos. DPR-53 and DPR-69 Mr. Bryan C. Hanson Senior Vice President Exelon Generation Company, LLC President and Chief Nuclear Officer Exelon Nuclear 4300 Winfield Road Warrenville, IL 60555 Catawba Nuclear Station Duke Energy Carolinas, LLC Docket Nos. 50-413 and 50-414 License Nos. NPF-35 and NPF-52 Mr. Kelvin Henderson Site Vice President Duke Energy Carolinas, LLC Catawba Nuclear Station 4800 Concord Road York, SC 297 45 Clinton Power Station Exelon Generation Company Docket No. 50-461 License No. NPF-62 Mr. Bryan C. Hanson Senior Vice President Exelon Generation Company, LLC President and Chief Nuclear Officer Exelon Nuclear 4300 Winfield Road Warrenville, IL 60555 Columbia Generating Station Energy Northwest Docket No. 50-397 License No. NPF-21 Mr. Mark E. Reddemann Chief Executive Officer Energy Northwest MD 1023 North Power Plant Loop P.O. Box 968 Richland, WA 99352 Comanche Peak Nuclear Power Plant Luminant Generation Company LLC Docket Nos. 50-445 and 50-446 License Nos. NPF-87 and NPF-89 Mr. Rafael Flores Senior Vice President and Chief Nuclear Officer Attention: Regulatory Affairs Luminant Generation Company, LLC P.O. Box 1002 Glen Rose, TX 76043 Cooper Nuclear Station Nebraska Public Power District Docket No. 50-298 License No. DPR-46 Mr. Oscar A. Limpias Vice President Nuclear and Chief Nuclear Officer Nebraska Public Power District 72676 648A Avenue P.O. Box 98 Brownville, NE 68321 Davis-Besse Nuclear Power Station First Energy Nuclear Operating Co.

Docket No. 50-346 License No. NPF-3 Mr. Brian D. Boles Site Vice President - 3 - FirstEnergy Nuclear Operating Company c/o Davis-Besse NPS 5501 N. State Route 2 Oak Harbor, OH 43449-9760 Diablo Canyon Power Plant Pacific Gas and Electric Co.

Docket Nos. 50-275 and 50-323 License Nos. DPR-80 and DPR-82 Mr. Edward D. Halpin Senior Vice President and Chief Nuclear Officer Pacific Gas and Electric Company P.O. Box 56, Mail Code 104/6 Avila Beach, CA 93424 Donald C. Cook Nuclear Plant Indiana Michigan Power Company Docket Nos. 50-315 and 50-316 License Nos. DPR-58 and DPR-74 Mr. Lawrence J. Weber Senior Vice President and Chief Nuclear Officer Indiana Michigan Power Company Nuclear Generation Group One Cook Place Bridgman, Ml 49106 Dresden Nuclear Power Station Exelon Generation Company, LLC Docket Nos. 50-237 and 50-249 License Nos. DPR-19 and DPR-25 Mr. Bryan C. Hanson Senior Vice President Exelon Generation Company, LLC President and Chief Nuclear Officer Exelon Nuclear 4300 Winfield Road Warrenville, IL 60555 Duane Arnold Energy Center NextEra Duane Arnold, LLC Docket No. 50-331 License No. DPR-49 Mr. Thomas A Vehec Site Vice President Next Era Energy Duane Arnold Energy Center 3277 DAEC Road Palo, IA 52324-9785 Edwin I. Hatch Nuclear Plant Southern Nuclear Operating Co.

Docket Nos. 50-321 and 50-366 License Nos. DPR-57 and NPF-5 Mr. C.R. Pierce Regulatory Affairs Director Southern Nuclear Operating Company, Inc.

P.O. Box 1295/BIN B038 Birmingham, AL 35201-1295 Fermi DTE Electric Company Docket No. 50-341 License No. NPF-43 Mr. Paul Fessler Senior Vice President and Chief Nuclear Officer DTE Electric Company Fermi 2 - 210 NOC 6400 North Dixie Highway Newport, Ml 48166 Fort Calhoun Station Omaha Public Power District Docket No. 50-285 License No. DPR-40 Mr. Louis Cortopassi Site Vice President and Chief Nuclear Officer Omaha Public Power District Fort Calhoun Station Mail Stop FC-2-4 9610 Power Lane Blair, NE 68008 Grand Gulf Nuclear Station Entergy Operations, Inc.

Docket No. 50-416 License No. NPF-29 Vice President, Operations Entergy Operations, Inc.

Grand Gulf Nuclear Station P.O. Box 756 Port Gibson, MS 39150 H. B. Robinson Steam Electric Plant Duke Energy Progress, Inc.

Docket No. 50-261 License No. DPR-23 Mr. Richard M. Glover, Site Vice President H.B. Robinson Steam Electric Plant Duke Energy 3581 West Entrance Road Hartsville, SC 29550 Hope Creek Generating Station PSEG Nuclear LLC Docket No. 50-354 License No. NPF-57 Mr. Robert Braun President and Chief Nuclear Officer PSEG Nuclear LLC - N09 P. 0. Box 236, Hancocks Bridge, NJ 08038 - 4 - Indian Point Nuclear Generating Entergy Nuclear Operations, Inc.

Docket Nos. 50-24 7 and 50-286 License Nos. DPR-26 and DPR-64 Vice President, Operations Entergy Nuclear Operations, Inc.

Indian Point Energy Center 450 Broadway, GSB P.O. Box 249 Buchanan, NY 10511-0249 James A. FitzPatrick Nuclear Power Plant Entergy Nuclear Operations, Inc.

Docket No. 50-333 License No. DPR-59 Vice President, Operations James A. FitzPatrick Nuclear Power Plant P.O. Box 110 Lycoming, NY 13093 Joseph M. Farley Nuclear Plant Southern Nuclear Operating Co., Inc.

Docket Nos. 50-348 and 50-364 License Nos. NPF-2 and NPF-8 Mr. C. R. Pierce, Regulatory Affairs Director Southern Nuclear Operating Co., Inc.

P.O. Box 1295, Bin 038 Birmingham, AL 35201-1295 LaSalle County Station Exelon Generation Company, LLC Docket Nos. 50-373 and 50-37 4 License Nos. NPF-11 and NPF-18 Mr. Bryan C. Hanson Senior Vice President Exelon Generation Company, LLC President and Chief Nuclear Office Exelon Nuclear 4300 Winfield Road Warrenville, IL 60555 Limerick Generating Station Exelon Generation Co., LLC Docket Nos 50-352 and 50-353 License Nos. NPF-39 and NPF-85 Mr. Bryan C. Hanson President and Chief Nuclear Office Exelon Nuclear 4300 Winfield Road Warrenville, IL 60555 McGuire Nuclear Station Duke Energy Carolinas, LLC Docket Nos. 50-369 and 50-370 License Nos. NPF-9 and NPF-17 Mr. Steven D. Capps Duke Energy Carolinas, LLC McGuire Nuclear Station 12700 Hagers Ferry Road Huntersville, NC 28078-8985 Millstone Nuclear Power Station Dominion Nuclear Connecticut, Inc.

Docket No. 50-245 License No. DPR-21 Mr. David A. Heacock President and Chief Nuclear Officer Dominion Nuclear Connecticut, Inc.

Innsbrook Technical Center 5000 Dominion Boulevard Glen Allen, VA 23060 Monticello Nuclear Generating Plant - 5 - Northern States Power Company - Minnesota Docket No. 50-263 License No. DPR-22 Mr. Peter A. Gardner Site Vice President Northern States Power Company - Minnesota Monticello Nuclear Generating Plant 2807 West County Road 75 Monticello, MN 55362-9637 Nine Mile Point Nuclear Station Nine Mile Point Nuclear Station, LLC Docket No. 50-220 License No. DPR-63 Mr. Bryan C. Hanson President and Chief Nuclear Officer Exelon Generation 4300 Winfield Road Warrenville, iL 60555 North Anna Power Station Virginia Electric and Power Co.

Docket Nos. 50-338 and 50-339 License Nos. NPF-4 and NPF-7 Mr. David A. Heacock President and Chief Nuclear Officer Virginia Electric and Power Co.

Innsbrook Technical Center 5000 Dominion Boulevard Glen Allen, VA 23060-6711 Oconee Nuclear Station Duke Energy Carolinas, LLC Docket Nos. 50-269, 50-270 and 50-287 License Nos. DPR-38, DPR-47 and DPR-55 Mr. Scott Batson Vice President, Oconee Nuclear Station Duke Energy Carolinas, LLC 7800 Rochester Highway Seneca, SC 29672 Oyster Creek Nuclear Generating Station Exelon Generation Co., LLC Docket No. 50-219 License No. DPR-16 Mr. Bryan C. Hanson Senior Vice President Exelon Generation Company, LLC President and Chief Nuclear Office Exelon Nuclear 4300 Winfield Road Warrenville, IL 60555 Palisades Nuclear Plant Entergy Nuclear Operations, Inc.

Docket No. 50-255 License No. DPR-20 Vice President, Operations Entergy Nuclear Operations, Inc.

Palisades Nuclear Plant 27780 Blue Star Memorial Highway Covert, Ml 49043 - 6 - Palo Verde Nuclear Generating Station Arizona Public Service Company Docket Nos. 50-528, 50-529 and 50-530 License Nos. NPF-41, NPF-51 and NPF-74 Mr. Randall K. Edington Executive Vice President Nuclear and Chief Nuclear Officer Arizona Public Service Co.

P.O. Box 52034, MS 7602 Phoenix, AZ 85072-2034 Peach Bottom Atomic Power Station Exelon Generation Co, LLC Docket Nos. 50-277 and 50-278 License Nos. DPR-44 and DPR-56 Mr. Bryan C. Hanson President and Chief Nuclear Office Exelon Nuclear 4300 Winfield Road Warrenville, IL 60555 Perry Nuclear Power Plant FirstEnergy Nuclear Operating Co.

Docket No. 50-440 License No. NPF-58 Mr. Ernest J. Harkness Site Vice President - Nuclear - Perry FirstEnergy Nuclear Operating Company Perry Nuclear Power Plant PO Box 97, A290 Perry, OH 44081 Pilgrim Nuclear Power Station Unit No. 1 Entergy Nuclear Generation Co.

Docket No. 50-293 License No. DPR-35 Mr. John Dent, Jr.

Vice President and Site Vice President Entergy Nuclear Operations, Inc.

Pilgrim Nuclear Power Station 600 Rocky Hill Road Plymouth, MA 02360-5508 Point Beach Nuclear Plant NextEra Energy Point Beach, LLC Docket Nos. 50-266 and 50-301 License Nos. DPR-24 and DPR-27 Mr. Eric McCartney Site Vice President NextEra Energy Point Beach, LLC 6610 Nuclear Road Two Rivers, WI 54241-9516 Prairie Island Nuclear Generating Plant Northern States Power Company - Minnesota Docket Nos. 50-282 and 50-306 License Nos. DPR-42 and DPR-60 Mr. Kevin K. Davison Site Vice President Northern States Power Company - Minnesota Prairie Island Nuclear Generating Plant 1717 Wakonade Drive East Welch, MN 55089-9642 Quad Cities Nuclear Power Station Exelon Generation Company, LLC Docket Nos. 50-254 and 50-265 License Nos. DPR-29 and DPR-30 Mr. Bryan C. Hanson Senior Vice President Exelon Generation Company, LLC President and Chief Nuclear Officer (CNO) Exelon Nuclear 4300 Winfield Road Warrenville, IL 60555 R. E. Ginna Nuclear Power Plant R. E. Ginna Nuclear Power Plant, LLC Docket No. 50-244

License No. DPR-18 Mr. Bryan C. Hanson President and Chief Nuclear Officer (CNO) Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 River Bend Station Entergy Operations, Inc.

Docket No. 50-458 License No. NPF-47 Vice President, Operations Entergy Operations, Inc.

River Bend Station 5485 U.S. Highway 61 N St. Francisville, LA 70775 Salem Nuclear Generating Station PSEG Nuclear LLC Docket Nos. 50-272 and 50-311 License Nos. DPR-70 and DPR-75 Mr. Robert Braun President and CNO PSEG Nuclear LLC-N09 P. 0. Box 236 Hancocks Bridge, NJ 08038 Seabrook StationNextEra Energy Seabrook, LLC Docket No 50-443 License No. NFP-86 Mr. Dean Curtland Vice President, Seabrook Nuclear Plant c/o Mr. Michael Ossing NextEra Energy Seabrook, LLC P.O. Box 300 Seabrook, NH 03874 Sequoyah Nuclear Plant Tennessee Valley Authority Docket Nos. 50-327 and 50-328 License Nos. DPR-77 and DPR-79 Mr. Joseph W. Shea Vice President, Nuclear Licensing Tennessee Valley Authority 1101 Market Street LP 3D-C Chattanooga, TN 37 402 Shearon Harris Nuclear Power Plant Duke Energy Progress, Inc.

Docket No. 50-400 License No. NPF-63 Mr. Benjamin C. Waldrep, Site Vice President Shearon Harris Nuclear Power Plant 5413 Shearon Harris Rd New Hill, NC 27562-0165 South Texas Project STP Nuclear Operating Company Docket Nos. 50-498 and 50-499 License Nos. NPF-76 and NPF-80 Mr. Dennis L. Koehl President and CEO/CNO STP Nuclear Operating Company South Texas Project P.O. Box 289 Wadsworth, TX 77483 St. Lucie Plant Florida Power and Light Company Docket Nos. 50-335 and 50-389 License Nos. DPR-67 and NPF-16 Mr. Mano Nazar President and Chief Nuclear Officer Nuclear Division NextEra Energy P.O. Box 14000 Juno Beach, FL 33408-0420 Surry Power Station Virginia Electric and Power Company Docket Nos. 50-280 and 50-281 License Nos. DPR-32 and DPR-37 Mr. David A. Heacock President and Chief Nuclear Officer Virginia Electric and Power Company 5000 Dominion Blvd.

Glen Allen, VA 23060-6711 Susquehanna Steam Electric Station Susquehanna Nuclear, LLC Docket Nos. 50-387 and 50-388 License Nos. NPF-14 and NPF-22 Mr. Jon A Franke Site Vice President Susquehanna Nuclear, LLC 769 Salem Boulevard NUCSB3 Berwick, PA 18603-0467 Three Mile Island Nuclear Station Exelon Generation Company, LLC.

Docket No. 50-289 License No. DPR-50 Mr. Bryan C. Hanson President and Chief Nuclear Office Exelon Nuclear 4300 Winfield Road Warrenville, IL 60555 Turkey Point Nuclear Generating Florida Power and Light Company Docket Nos. 50-250 and 50-251 License Nos. DPR-31 and DPR-41 Mr. Mano Nazar President and Chief Nuclear Officer Nuclear Division NextEra Energy P. 0. Box 14000 Juno Beach, FL 33408-0420 Virgil C. Summer Nuclear Station - 8 - South Carolina Electric and Gas Company Docket No. 50-395 License No. NPF-12 Mr. Thomas D. Gatlin, Vice President Nuclear Operations South Carolina Electric & Gas Company Virgil C. Summer Nuclear Station Post Office Box 88, Mail Code 800 Jenkinsville, SC 29065 Vogtle Electric Generating Plant Southern Nuclear Operating Company, Inc.

Docket Nos. 50-424 and 50-425 License Nos. NPF-68 and NPF-81 Mr. C. R. Pierce Regulatory Affairs Director Southern Nuclear Operating Co., Inc.

P. 0. Box 1295 /Bin 038 Birmingham, AL 35201-1295 Waterford Steam Electric Station Entergy Operations, Inc.

Docket No. 50-382 License No. NPF-38 Site Vice President Entergy Operations, Inc.

Waterford Steam Electric Station, Unit 3 17265 River Road Killona, LA 70057-0751 Watts Bar Nuclear Plant Tennessee Valley Authority Docket Nos. 50-390 and 50-391 License Nos. NPF-90 Mr. Joseph W. Shea Vice President, Nuclear Licensing Tennessee Valley Authority 1101 Market Street, LP 3D-C Chattanooga, TN 37 402-2801 Wolf Creek Generating Station Wolf Creek Nuclear Operating Corporation Docket No. 50-482 License No. NPF-42 Mr. Adam C. Heflin President, Chief Executive Officer, And Chief Nuclear Officer Wolf Creek Nuclear Operating Corporation P.O. Box 411 Burlington, KS 66839 - 5 - with NEI letter dated July 30, 2015, submittal of IPEEE relay chatter evaluation is due December 31, 2016. Option 2 allows for completion using the HF evaluation approach. In choosing one of the two options, these licensees should consider that a relay chatter study will continue to be needed for the IPEEE submittal to meet the SPID acceptance criteria. Meeting the SPID criteria will be necessary if a licensee plans to rely on the IPEEE results in its mitigation strategies assessment with respect to the reevaluated hazard.

If you have any questions regarding this letter, please contact Nicholas DiFrancesco at 301-415-1115 or via email at Nicholas.Difrancesco@nrc.gov.

Enclosures:

1. Recommendation 2.1 Seismic - Information Request Tables 2. Glossary of Recommendation

2.1 Seismic Evaluations

3. Seismic Hazard Submittals and Prior Screening Letters 4. List of Licensees cc: Listserv DISTRIBUTION:

See next page ADAMS Accession No.: ML 15194A015 OFFICE NRR/JLD/PMB/PM NRR/JLD/LA NAME NDiFrancesco SLent DATE 08/17/2015 08/31/2015 OFFICE NRO/DSEND OGC NAME SFlanders BHarris (NLO) DATE 09/23/2015 09/22/2015 Sincerely, /RAJ William M. Dean, Director Office of Nuclear Reactor Regulation NRR/JLD/HMB/BC NRO/DSENRGS2/BC MShams DJackson 10/06/2015 10/08/2015 NRR/JLD/D NRR/D JDavis WDean 10/8/2015 10/27/2015 OFFICIAL RECORD COPY

  • via email NRR/DRN/BC SRosenbera 09/15/2015 Letter to the Power Reactor Licensees on the Enclosed List from William M. Dean dated October 27, 2015.

SUBJECT: FINAL DETERMINATION OF LICENSEE SEISMIC PROBABILISTIC RISK ASSESSMENTS UNDER THE REQUEST FOR INFORMATION PURSUANT TO TITLE 10 OF THE CODE OF FEDERAL REGULATIONS 50.54(f) REGARDING RECOMMENDATION 2.1 "SEISMIC" OF THE NEAR-TERM TASK FORCE REVIEW OF INSIGHTS FROM THE FUKUSHIMA DAl-ICHI ACCIDENT DISTRIBUTION:

PUBLIC RidsNroOd RidsNrrDorl RidsNrrDorllpl1-1 RidsNrrDorllpl1-2 RidsN rrDorl Lpl2-1 RidsNrrDorllpl2-2 RidsNrrDorllpl3-1 RidsNrrDorllpl3-2 RidsNrrDorllpl4-1 RidsN rrDorl Lpl4-2 RidsN rrDorl Lp WB RidsNrrOd RidsNsirOd RidsOeMailCenter RidsOgcMailCenter MKhanna, NRR RPascarelli, NRR BBeasley, NRR JQuichocho, NRR TTate, NRR MMarkley, NRR DBroaddus, NRR NDiFrancesco, NRR RidsNrrLAJBurkhardt RidsNrrLABClayton RidsNrrLASFigueroa RidsNrrLAKGoldstein RidsNrrLASRohrer RidsNrrlaSLent RidsNrrLAMHenderson RidsNrrLAPBlechman RidsNrrLALRonewicz RidsNrrPMANO RidsNrrPMBeaverValley RidsNrrPMBellefonte RidsNrrPMBraidwood RidsNrrPMBrownsFerry RidsNrrPMBrunswick RidsNrrPMByron RidsNrrPMCallaway RidsNrrPMCalvertCliffs RidsNrrPMCatawba RidsNrrPMClinton RidsNrrPMColumbia RidsN rrPMComanchePeak RidsNrrPMCooper RidsNrrPMDCCook RidsNrrPM Davis Besse RidsNrrPMDiabloCanyon RidsNrrPMDresden RidsNrrPMDuaneArnold RidsNrrPMFarley RidsNrrPMFermi2 RidsNrrPMFitzPatrick RidsNrrPMFortCalhoun RidsNrrPMHatch RidsN rrHopeCreek RidsNrrPMlndianPoint RidsNrrPMLaSalle RidsNrrPMLimerick RidsNrrPMMcGuire RidsNrrPMMillstone RidsNrrPMMonticello RidsNrrPMNineMilePoint RidsNrrPMNorthAnna RidsNrrPMOconee RidsNrrPMOysterCreek RidsNrrPMPalisades RidsNrrPaloVerde RidsNrrPMPeachBottom RidsNrrPMPerry RidsNrrPMPilgrim RidsNrrPM PointBeach RidsNrrPMPrairielsland RidsNrrPMQuadCities RidsNrrPMREGinna RidsNrrPMRiverBend RidsNrrPMRobinson RidsNrrPMSalem RidsNrrPMSeabrook RidsNrrPMSequoyah RidsNrrPMSouth Texas RidsNrrPMStlucie RidsNrrPMSummer RidsNrrPMSusquehanna RidsNrrPMThreeMilelsland RidsNrrPMTurkeyPoint RidsN rrPMVogtle RidsN rrPMWaterford RidsNrrPMWattsBar1 RidsNrrPMWattsBar2 RidsNrrPMWolfCreek RidsOgcRp Resource RidsRgn1 MailCenter RidsRgn2MailCenter RidsRgn3MailCenter RidsRgn4MailCenter RidsEdoMailCenter Resource RidsNroOd RidsNrrOd RidsNsirOd MShams, NRR AKock, NRO DJackson, NRO SDevlin-Gill, NRO RidsOgcRp Resource

  1. 1 Enclosure 2 of this letter provides a glossary of seismic-related evaluations.
  2. 2 Agencywide Documents Access and Management System (ADAMS) Accession No. ML12053A340.
  3. 3 Additional seismic hazard screening letters are listed in Enclosure 3.
  4. 5 Screening and Prioritization for Western United States Sites can be found at ADAMS Accession No. ML15113B344.
  5. 6 Guidance would have allowed a few sites to complete Seismic Margin Assessments (SMAs) due to the small amount of reevaluated hazard exceedance above the plant design-basis.
  6. 7 The NRC endorsed the SPID guidance by letter dated February 15, 2013 (ADAMS Accession No. ML12319A074).
  7. 8 The NRC and the Nuclear Energy Institute (NEI) September 3, 2015, public meeting slides can be found in ADAMS Accession Nos. ML15247A225, ML15245A714, and ML15245A720, respectively.