RNP-RA/15-0069, Addendum to Submittal of Revision to Seismic Hazard Evaluation to Include New Ground Motion Response Spectra (GMRS) Using New Geotechnical Data and Shear-Wave Testing

From kanterella
(Redirected from ML15243A061)
Jump to navigation Jump to search

Addendum to Submittal of Revision to Seismic Hazard Evaluation to Include New Ground Motion Response Spectra (GMRS) Using New Geotechnical Data and Shear-Wave Testing
ML15243A061
Person / Time
Site: Robinson 
Issue date: 08/29/2015
From: Glover R
Duke Energy Progress
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
RNP-RA/15-0069
Download: ML15243A061 (10)


Text

(_~ DUKE ENERGY~

Serial: RNP-RA/15-0069 AUG 2 9 2015 ATTN: Document Control Desk U. S. Nuclear Regulatory Commission Washington, DC 20555 H. B. ROBINSON STEAM ELECTRIC PLANT, UNIT NO. 2 DOCKET NO. 50-261 I RENEWED LICENSE NO. DPR-23 R. Michael Glover H. B. Robinson Steam Electric Plant Unit 2 Site Vice President Duke Energy Progress 3581 West Entrance Road Hartsville, SC 29550 0 : 843 857 1704 F: 843 857 1319 Mike. Glovet@duke-ellergy.colll 10 CFR 50.54(f)

Subject:

Addendum to Submittal of Revision to Seismic Hazard Evaluation to Include New Ground Motion Response Spectra (GMRS) Using New Geotechnical Data and Shear-Wave Testing for H. B. Robinson Steam Electric Plant, Unit No. 2

References:

Duke Energy letter to NRC, Submittal of Revision to Seismic Hazard Evaluation to Include New Ground Motion Response Spectra (GMRS) Using New Geotechnical Data and Shear-Wave Testing for H. B. Robinson Steam Electric Plant, Unit No. 2, dated July 17, 2015 Ladies and Gentlemen:

The above reference provided the NRC with a revised Duke Energy GMRS Submittal for H. B.

Robinson Steam Electric Plant, Unit No. 2, using new geotechnical data collected during onsite exploration and additional shear wave velocities testing.

The purpose of this letter is to submit an addendum to that submittal to provide the Amplification Functions data for H. B. Robinson Steam Electric Plant, Unit No. 2. These Amplification Functions data are provided in the enclosed tables.

This letter contains no new regulatory commitments.

If you have any questions or require additional information, please contact Richard Hightower, Manager, Nuclear Regulatory Affairs at (843)-857 -1329.

I declare under the penalty of perjury that the foregoing is true and correct.

Executed on A v (:/) \\- Z~ 1 ;;L\\)').

Sincerely, R. Michael Glover Site Vice President

U.S. Nuclear Regulatory Commission Serial: RNP-RA/15-0069 Page 2 of 2 RMG/shc

Enclosure:

Amplification Functions for H. B. Robinson Steam Electric Plant, Unit No. 2 cc:

Ms. M. C. Barillas, NRC Project Manager, NRR Mr. K. M. Ellis, NRC Sr. Resident Inspector Mr. V. M. McCree, NRC Region II Administrator Mr. N.J. DiFrancesco, NRC Senior Project Manager, JLD-NRR

U.S. Nuclear Regulatory Commission Enclosure to Serial: RNP-RA/15-0069 Page 1 ofB ENCLOSURE AMPLIFICATION FUNCTIONS FOR H. B. ROBINSON STEAM ELECTRIC PLANT, UNIT NO.2

U.S. Nuclear Regulatory Commission Enclosure to Serial: RNP-RA/15-0069 Page 2 of 8 Profile A -Clay Set PGA (g)

Median Sigma AF ln(AF) 5.00E-03 1.65E+OO 1.85E-01 1.80E-02 1.52E+OO 1.91 E-01 5.50E-02 1.30E+OO 2.17E-01 8.50E-02 1.19E+OO 2.31 E-01 1.25E-01 1.10E+OO 2.04E-01 1.80E-01 9.71E-01 2.27E-01 3.00E-01 7.94E-01 2.65E-01 6.00E-01 5.52E-01 2.77E-01 6.87E-01 5.00E-01 2.84E-01 7.56E-01 5.00E-01 1.00E-02 Profile C - Clay Set PGA(g)

Median Sigma AF ln(AF) 5.00E-03 2.24E+OO 1.51 E-01 1.80E-02 2.17E+OO 1.47E-01 5.50E-02 1.95E+OO 1.52E-01 8.50E-02 1.86E+OO 1.50E-01 1.25E-01 1.71 E+OO 1.74E-01 1.80E-01 1.54E+OO 2.14E-01 3.00E-01 1.38E+OO 2.27E-01 6.00E-01 1.10E+OO 2.87E-01 B.OOE-01 9.22E-01 2.83E-01 2.00E+OO 6.13E-01 2.69E-01 Table A-Sa. Amplification Functions for PGA Profile A-Sand Set Profile B - Clay Set Profile B - Sand Set PGA (g)

Median Sigma PGA(g)

Median Sigma PGA(g)

Median Sigma AF ln(AF)

AF ln(AF)

AF ln(AF) 5.00E-03 1.64E+OO 1.90E-01 5.00E-03 2.15E+OO 1.77E-01 5.00E-03 2.11E+OO 1.82E-01 1.80E-02 1.43E+OO 1.87E-01 1.80E-02 1.99E+OO 1.82E-01 1.80E-02 1.91 E+OO 1.85E-01 5.50E-02 1.17E+OO 2.21E-01 5.50E-02 1.76E+OO 1.90E-01 5.50E-02 1.55E+OO 1.86E-01 8.50E-02 9.49E-01 2.38E-01 8.50E-02 1.59E+OO 2.07E-01 8.50E-02 1.32E+OO 2.25E-01 1.25E-01 8.76E-01 2.40E-01 1.25E-01 1.45E+OO 1.93E-01 1.25E-01 1.14E+OO 2.54E-01 1.80E-01 7.13E-01 2.62E-01 1.80E-01 1.30E+OO 2.01E-01 1.80E-01 9.60E-01 2.59E-01 3.00E-01 5.43E-01 3.04E-01 3.00E-01 1.06E+OO 2.62E-01 3.00E-01 7.24E-01 3.01E-01 3.43E-01 5.00E-01 3.00E-01 6.00E-01 7.82E-01 3.15E-01 5.51 E-01 5.00E-01 4.03E-01 3.78E-01 5.00E-01 1.00E-02 B.OOE-01 6.22E-01 3.20E-01 6.06E-01 5.00E-01 1.00E-02 1.98E+OO 5.00E-01 3.36E-01 2.18E+OO 5.00E-01 1.00E-02 Profile C - Sand Set PGA(g)

Median Sigma AF ln(AF) 5.00E-03 2.24E+OO 1.47E-01 1.80E-02 2.08E+OO 1.45E-01 5.50E-02 1.79E+OO 1.60E-01 8.50E-02 1.63E+OO 1.74E-01 1.25E-01 1.39E+OO 2.58E-01 1.80E-01 1.21E+OO 2.95E-01 3.00E-01 9.96E-01 3.03E-01 6.00E-01 6.71 E-01 3.18E-01 B.OOE-01 5.40E-01 3.42E-01 8.79E-01 5.00E-01 3.49E-01 9.67E-01 5.00E-01 1.00E-02

U. S. Nuclear Regulatory Commission Enclosure to Serial: RNP-RA/15-0069 Page 3 of 8 Profile A -Clay Set 25Hz Median Sigma PSA(g)

AF ln(AF) 1.00E-02 1.50E+OO 2.01E-01 4.00E-02 1.32E+OO 1.91 E-01 1.20E-01 1.04E+OO 2.33E-01 2.00E-01 8.32E-01 2.57E-01 3.00E-01 7.71 E-01 2.49E-01 5.00E-01 5.74E-01 3.26E-01 6.45E-01 5.00E-01 2.62E-01 7.09E-01 5.00E-01 1.00E-02 Profile C - Clay Set 25Hz Median Sigma PSA (g)

AF ln(AF) 1.00E-02 2.04E+OO 1.75E-01 4.00E-02 1.91E+OO 1.63E-01 1.20E-01 1.67E+OO 2.39E-01 2.00E-01 1.45E+OO 2.13E-01 3.00E-01 1.34E+OO 2.44E-01 5.00E-01 1.08E+OO 3.59E-01

?.OOE-01 9.23E-01 3.66E-01 1.00E+OO 8.43E-01 3.26E-01 1.80E+OO 5.83E-01 3.80E-01 2.26E+OO S.OOE-01 4.01E-01 2.49E+OO 5.00E-01 1.00E-02 Table A-8b. Amplification Functions for 25 Hz (T = 0.04 s)

Profile A-Sand Set Profile B - Clay Set Profile B - Sand Set 25Hz Median Sigma 25Hz Median Sigma 25Hz Median Sigma PSA(g)

AF ln(AF)

PSA(g)

AF ln(AF)

PSA (g)

AF ln(AF) 1.00E-02 1.51 E+OO 1.91 E-01 1.00E-02 1.86E+OO 1.98E-01 1.00E-02 1.82E+OO 1.86E-01 4.00E-02 1.21 E+OO 2.14E-01 4.00E-02 1.65E+OO 1.87E-01 4.00E-02 1.55E+OO 1.87E-01 1.20E-01 8.22E-01 2.26E-01 1.20E-01 1.38E+OO 2.49E-01 1.20E-01 1.11E+OO 3.36E-01 2.00E-01 5.83E-01 3.07E-01 2.00E-01 1.15E+OO 2.15E-01 2.00E-01 8.30E-01 2.80E-01 3.00E-01 5.44E-01 2.98E-01 3.00E-01 1.03E+OO 2.44E-01 3.00E-01 7.06E-01 3.29E-01 3.31 E-01 5.00E-01 3.08E-01 5.00E-01 7.81E-01 2.60E-01 4.70E-01 5.00E-01 3.70E-01 3.64E-01 5.00E-01 1.00E-02 7.00E-01 6.41 E-01 3.49E-01 5.17E-01 5.00E-01 1.00E-02 1.00E+OO 5.57E-01 3.63E-01 1.15E+OO 5.00E-01 3.66E-01 1.27E+OO 5.00E-01 1.00E-02 Profile C - Sand Set 25Hz Median Sigma PSA (g)

AF ln(AF) 1.00E-02 2.03E+OO 1.60E-01 4.00E-02 1.80E+OO 1.81 E-01 1.20E-01 1.42E+OO 2.90E-01 2.00E-01 1.12E+OO 2.83E-01 3.00E-01 9.61 E-01 3.70E-01 5.00E-01 6.72E-01 4.53E-01 7.00E-01 5.41 E-01 4.21 E-01 8.45E-01 5.00E-01 3.96E-01 9.30E-01 5.00E-01 1.00E-02

U.S. Nuclear Regulatory Commission Enclosure to Serial: RNP-RA/15-0069 Page 4 of 8 Table A-Bc. Amplification Functions for 10Hz (T = 0.1 s)

Profile A -Clay Set Profile A-Sand Set Profile B - Clay Set Profile B - Sand Set 10 Hz Median Sigma 10 Hz Median Sigma 10 Hz Median Sigma 10 Hz Median Sigma PSA (g)

AF ln(AF)

PSA (g)

AF ln(AF)

PSA (g)

AF ln(AF)

PSA (g)

AF ln(AF) 1.00E-02 1.61 E+OO 3.02E-01 1.00E-02 1.60E+OO 3.07E-01 1.00E-02 2.39E+OO 2.57E-01 1.00E-02 2.35E+OO 2.29E-01 4.00E-02 1.49E+OO 3.37E-01 4.00E-02 1.43E+OO 2.99E-01 4.00E-02 2.21 E+OO 1.83E-01 4.00E-02 2.08E+OO 1.64E-01 1.20E-01 1.31 E+OO 2.64E-01 1.20E-01 1.12E+OO 2.87E-01 1.20E-01 1.90E+OO 2.84E-01 1.20E-01 1.62E+OO 3.35E-01 1.80E-01 1.18E+OO 3.34E-01 1.80E-01 9.25E-01 3.35E-01 1.80E-01

1. 7 4E+OO 2.32E-01 1.80E-01 1.37E+OO 2.64E-01 2.50E-01 1.14E+OO 3.01 E-01 2.50E-01 9.28E-01 3.07E-01 2.50E-01
1. 70E+OO 2.63E-01 2.50E-01 1.35E+OO 3.33E-01 4.00E-01 9.88E-01 3.17E-01 4.00E-01 7.09E-01 3.13E-01 4.00E-01 1.46E+OO 3.11 E-01 4.00E-01 1.01 E+OO 3.78E-01 5.50E-01 8.61 E-01 3.20E-01 5.50E-01
5. 70E-01 3.51 E-01 5.50E-01 1.30E+OO 3.14E-01 5.50E-01 8.35E-01 3.95E-01 1.00E+OO 6.81 E-01 3.21 E-01 6.88E-01 5.00E-01 3.53E-01 1.00E+OO 1.03E+OO 3.45E-01 1.00E+OO
5. 77E-01 4.51 E-01 1.54E+OO 5.00E-01 3.69E-01 7.57E-01 5.00E-01 1.00E-02 1.80E+OO 7.01 E-01 3.68E-01 1.17E+OO 5.00E-01 4.59E-01 1.69E+OO 5.00E-01 1.00E-02 2.61 E+OO 5.24E-01 3.83E-01 1.28E+OO 5.00E-01 1.00E-02 Profile C - Clay Set Profile C - Sand Set 10 Hz Median Sigma 10 Hz Median Sigma PSA (g)

AF ln(AF)

PSA (g)

AF ln(AF) 1.00E-02 2.60E+OO 2.36E-01 1.00E-02 2.60E+OO 1.98E-01 4.00E-02 2.50E+OO 1.48E-01 4.00E-02 2.40E+OO 2.03E-01 1.20E-01 2.25E+OO 2.36E-01 1.20E-01 1.97E+OO 2.63E-01 1.80E-01 2.09E+OO 2.21 E-01 1.80E-01

1. 73E+OO 2.39E-01 2.50E-01 2.03E+OO 2.54E-01 2.50E-01 1.67E+OO 2.88E-01 4.00E-01 1.81 E+OO 2.44E-01 4.00E-01 1.32E+OO 2.98E-01 5.50E-01 1.66E+OO 2.54E-01 5.50E-01 1.14E+OO 3.37E-01 1.00E+OO 1.38E+OO 2.69E-01 1.00E+OO 8.23E-01 3.48E-01 1.80E+OO 1.04E+OO 3.19E-01 1.80E+OO 5.37E-01 4.48E-01 2.61 E+OO 8.16E-01 3.51 E-01 1.94E+OO 5.00E-01 4.61 E-01

_ 2.13E+OO 5.00E-01

_!_.OOE-0~

U. 5. Nuclear Regulatory Commission Enclosure to Serial: RNP-RA/15-0069 Page 5 of 8 Profile A -Clay Set 5Hz Median Sigma PSA (g)

AF ln(AF) 8.50E-03 2.35E+OO 4.32E-01 3.00E-02 2.20E+OO 3.38E-01 9.00E-02 1.88E+OO 3.88E-01 1.40E-01 1.67E+OO 4.59E-01 1.90E-01 1.62E+OO 4.01E-01 3.00E-01 1.41E+OO 3.81 E-01 5.00E-01 1.17E+OO 3.81E-01 1.00E+OO 8.50E-01 4.43E-01 1.70E+OO 5.86E-01 4.91E-01 Profile C - Clay Set 5Hz Median Sigma PSA (g)

AF ln(AF) 8.50E-03 2.77E+OO 2.31E-01 3.00E-02 2.70E+OO 2.53E-01 9.00E-02 2.56E+OO 2.68E-01 1.40E-01 2.44E+OO 2.63E-01 1.90E-01 2.35E+OO 2.53E-01 3.00E-01 2.21E+OO 2.91E-01 5.00E-01 2.03E+OO 2.26E-01 1.00E+OO 1.74E+OO 2.54E-01 1.70E+OO 1.46E+OO 2.75E-01 Table A-Bd. Amplification Functions for 5 Hz (T = 0.2 s)

Profile A - Sand Set Profile B - Clay Set Profile B - Sand Set 5Hz Median Sigma 5Hz Median Sigma 5Hz Median Sigma PSA (g)

AF ln(AF)

PSA (g)

AF ln(AF)

PSA (g)

AF ln(AF)

I 8.50E-03 2.27E+OO 4.10E-01 8.50E-03 3.02E+OO 2.99E-01 8.50E-03 2.94E+OO 2.78E-01 I

3.00E-02 2.01E+OO 3.47E-01 3.00E-02 2.85E+OO 3.06E-01 3.00E-02 2.65E+OO 3.51 E-01 9.00E-02 1.62E+OO 4.02E-01 9.00E-02 2.49E+OO 3.41 E-01 9.00E-02 2.12E+OO 3.56E-01 1.40E-01 1.35E+OO 4.28E-01 1.40E-01 2.25E+OO 3.86E-01 1.40E-01 1.80E+OO 4.14E-01 I

1.90E-01 1.29E+OO 3.92E-01 1.90E-01 2.12E+OO 3.82E-01 1.90E-01 1.68E+OO 4.18E-01 I

3.00E-01 1.05E+OO 3.84E-01 3.00E-01 1.83E+OO 3.89E-01 3.00E-01 1.35E+OO 3.97E-01 5.00E-01 8.04E-01 4.26E-01 5.00E-01 1.56E+OO 4.07E-01 5.00E-01 1.10E+OO 3.85E-01 1.00E+OO 5.30E-01 4.86E-01 1.00E+OO 1.17E+OO 4.15E-01 1.00E+OO 7.18E-01 4.58E-01 1.07E+OO 5.00E-01 4.92E-01 1.70E+OO 8.63E-01 4.20E-01 1.51E+OO 5.00E-01 5.01E-01 I

1.18E+OO 5.00E-01 1.00E-02 1.66E+OO 5.00E-01 1.00E-02 Profile C - Sand Set 5Hz Median Sigma PSA (g)

AF ln(AF) 8.50E-03 2.75E+OO 2.38E-01 3.00E-02 2.64E+OO 2.67E-01 9.00E-02 2.37E+OO 2.98E-01 1.40E-01 2.17E+OO 2.28E-01 1.90E-01 2.10E+OO 2.51 E-01 3.00E-01 1.86E+OO 2.97E-01 5.00E-01 1.60E+OO 2.43E-01 1.00E+OO 1.17E+OO 3.50E-01 1.70E+OO 7.90E-01 4.32E-01

U.S. Nuclear Regulatory Commission Enclosure to Serial: RNP-RA/15-0069 Page 6 of 8 Profile A -Clay Set 2.5Hz Median Sigma PSA(g)

AF ln(AF)

S.SOE-03 2.32E+OO 2.99E-01 1.80E-02 2.29E+OO 2.68E-01 6.00E-02 2.15E+OO 3.54E-01 8.50E-02 2.08E+OO 3.44E-01 1.40E-01 1.98E+OO 3.59E-01 2.10E-01 1.80E+OO 4.33E-01 2.80E-01 1.62E+OO 4.42E-01 6.00E-01 1.11E+OO 4.87E-01 1.10E+OO 6.59E-01 5.24E-01 Profile C - Clay Set 2.5 Hz Median Sigma PSA (g)

AF ln(AF) 5.50E-03 3.08E+OO 3.01E-01 1.80E-02 3.06E+OO 3.18E-01 6.00E-02 3.05E+OO 2.61E-01 8.50E-02 3.01E+OO 2.79E-01 1.40E-01 2.96E+OO 3.18E-01 2.10E-01 2.89E+OO 2.77E-01 2.80E-01 2.79E+OO 2.84E-01 6.00E-01 2.43E+OO 3.25E-01 1.10E+OO 1.80E+OO 3.59E-01 Table A-8e. Amplification Functions for 2.5 Hz (T = 0.4 s)

Profile A - Sand Set Profile B - Clay Set Profile B - Sand Set 2.5 Hz Median Sigma 2.5 Hz Median Sigma 2.5Hz Median Sigma PSA(g)

AF ln(AF)

PSA(g)

AF ln(AF)

PSA(g)

AF ln(AF)

S.SOE-03 2.35E+OO 3.06E-01 S.SOE-03 2.72E+OO 2.69E-01 S.SOE-03 2.73E+OO 2.63E-01 1.80E-02 2.29E+OO 3.02E-01 1.80E-02 2.67E+OO 2.53E-01 1.80E-02 2.68E+OO 2.65E-01 6.00E-02 2.05E+OO 3.62E-01 6.00E-02 2.61E+OO 2.69E-01 6.00E-02 2.54E+OO 2.71E-01 8.50E-02 1.90E+OO 3.80E-01 8.50E-02 2.57E+OO 2.80E-01 8.50E-02 2.41 E+OO 2.73E-01 1.40E-01 1.70E+OO 3.84E-01 1.40E-01 2.48E+OO 2.96E-01 1.40E-01 2.21E+OO 2.58E-01 I

2.10E-01 1.41E+OO 5.15E-01 2.10E-01 2.37E+OO 3.03E-01 2.10E-01 1.86E+OO 3.47E-01 2.80E-01 1.21E+OO 4.29E-01 2.80E-01 2.20E+OO 2.62E-01 2.80E-01 1.62E+OO 3.85E-01 6.00E-01 6.40E-01 4.95E-01 6.00E-01 1.62E+OO 3.60E-01 6.00E-01 9.82E-01 4.70E-01 1

7.67E-01 S.OOE-01 5.16E-01 1.10E+OO 1.10E+OO 4.38E-01 1.10E+OO 5.34E-01 5.37E-01 8.44E-01 S.OOE-01 1.00E-02 I

Profile C - Sand Set 2.5Hz Median Sigma PSA (g)

AF ln(AF) 5.50E-03 3.10E+OO 2.98E-01 1.80E-02 3.08E+OO 3.27E-01 6.00E-02 2.99E+OO 2.19E-01 8.50E-02 2.90E+OO 2.87E-01 1.40E-01 2.73E+OO 2.99E-01 2.10E-01 2.51E+OO 3.08E-01 2.80E-01 2.33E+OO 3.16E-01 6.00E-01 1.38E+OO 3.88E-01 1.10E+OO 8.79E-01 4.46E-01

U. S. Nuclear Regulatory Commission Enclosure to Serial: RNP-RA/15-0069 Page 7 of 8 Profile A -Clay Set 1Hz Median Sigma PSA (g)

AF ln(AF) 2.40E-03 4.40E+OO 1.98E-01 9.00E-03 4.28E+OO 1.82E-01 2.80E-02 3.86E+OO 2.59E-01 4.00E-02 3.58E+OO 3.39E-01 6.00E-02 3.36E+OO 3.48E-01 9.00E-02 2.82E+OO 3.85E-01 1.60E-01 2.18E+OO 4.81E-01 2.50E-01 1.55E+OO 4.81 E-01 5.00E-01 8.96E-01 4.81 E-01 Profile C - Clay Set 1Hz Median Sigma PSA (g)

AF ln(AF) 2.40E-03 2.10E+OO 1.74E-01 9.00E-03 2.14E+OO 1.88E-01 2.80E-02 2.19E+OO 2.37E-01 4.00E-02 2.24E+OO 2.32E-01 6.00E-02 2.28E+OO 2.26E-01 9.00E-02 2.35E+OO 2.26E-01 1.60E-01 2.53E+OO 2.09E-01 2.50E-01 2.70E+OO 2.42E-01 5.00E-01 2.93E+OO 2.92E-01 Table A-Sf. Amplification Functions for 1Hz (T = 1.0 s)

Profile A-Sand Set Profile B - Clay Set Profile B - Sand Set 1Hz Median Sigma 1Hz Median Sigma 1Hz Median Sigma PSA (g)

AF ln(AF)

PSA (g)

AF ln(AF)

PSA (g)

AF ln(AF) 2.40E-03 4.45E+OO 1.90E-01 2.40E-03 2.99E+OO 2.68E-01 2.40E-03 3.03E+OO 2.71 E-01 9.00E-03 4.19E+OO 2.01E-01 9.00E-03 3.03E+OO 2.76E-01 9.00E-03 3.12E+OO 2.99E-01 2.80E-02 3.46E+OO 3.26E-01 2.80E-02 3.17E+OO 3.18E-01 2.80E-02 3.32E+OO 3.16E-01 4.00E-02 3.04E+OO 3.96E-01 4.00E-02 3.23E+OO 3.13E-01 4.00E-02 3.36E+OO 3.03E-01 6.00E-02 2.66E+OO 4.25E-01 6.00E-02 3.34E+OO 3.14E-01 6.00E-02 3.42E+OO 2.64E-01 9.00E-02 2.12E+OO 4.80E-01 9.00E-02 3.46E+OO 2.47E-01 9.00E-02 3.37E+OO 2.60E-01 1.60E-01 1.54E+OO 5.01E-01 1.60E-01 3.17E+OO 2.80E-01 1.60E-01 2.68E+OO 3.56E-01 2.50E-01 1.05E+OO 4.77E-01 2.50E-01 2.86E+OO 3.59E-01 2.50E-01 2.01E+OO 4.20E-01 S.OOE-01 7.55E-01 4.39E-01 5.00E-01 1.85E+OO 4.83E-01 5.00E-01 1.15E+OO 5.19E-01 Profile C - Sand Set 1Hz Median Sigma PSA (g)

AF ln(AF) 2.40E-03 2.13E+OO 1.78E-01 9.00E-03 2.19E+OO 2.09E-01 2.80E-02 2.27E+OO 2.50E-01 4.00E-02 2.35E+OO 2.37E-01 6.00E-02 2.45E+OO 2.27E-01 9.00E-02 2.61E+OO 1.78E-01 1.60E-01 2.91E+OO 2.92E-01 2.50E-01 2.99E+OO 3.66E-01 5.00E-01 2.17E+OO 4.81 E-01

U. S. Nuclear Regulatory Commission Enclosure to Serial: RNP-RA/15-0069 Page 8 of 8 Profile A -Clay Set 0.5Hz Median Sigma PSA (g)

AF ln(AF) 1.40E-03 1.72E+OO 1.86E-01 5.00E-03 1.73E+OO 1.57E-01 1.50E-02 1.81 E+OO 2.22E-01 2.30E-02 1.84E+OO 2.04E-01 3.50E-02 1.91E+OO 2.90E-01 5.50E-02 2.01E+OO 1.49E-01 7.00E-02 2.08E+OO 2.59E-01 1.00E-01 2.23E+OO 3.39E-01 1.30E-01 2.31E+OO 2.59E-01 1.70E-01 2.37E+OO 2.84E-01 3.00E-01 2.17E+OO 3.38E-01 Profile C - Clay Set 0.5 Hz Median Sigma PSA (g)

AF ln(AF) 1.40E-03 1.22E+OO 6.34E-02 5.00E-03 1.22E+OO 6.08E-02 1.50E-02 1.23E+OO 7.01 E-02 2.30E-02 1.24E+OO 6.83E-02 3.50E-02 1.22E+OO 5.32E-02 5.50E-02 1.24E+OO 1.22E-01 7.00E-02 1.26E+OO 8.08E-02 1.00E-01 1.29E+OO 1.57E-01 1.30E-01 1.33E+OO 1.35E-01 1.70E-01 1.38E+OO 1.73E-01 3.00E-01 1.51E+OO 2.53E-01 Table A-Bg. Amplification Functions for 0.5 Hz (T = 2.0 s)

Profile A-Sand Set Profile B - Clay Set Profile B - Sand Set 0.5 Hz Median Sigma 0.5 Hz Median Sigma 0.5 Hz Median Sigma PSA (g)

AF ln(AF)

PSA (g)

AF ln(AF)

PSA (g)

AF ln(AF) 1.40E-03 1.73E+OO 1.85E-01 1.40E-03 1.33E+OO 9.36E-02 1.40E-03 1.34E+OO 9.16E-02 I

5.00E-03 1.76E+OO 1.68E-01 5.00E-03 1.34E+OO 9.91 E-02 5.00E-03 1.36E+OO 1.17E-01 1.50E-02 1.91E+OO 2.83E-01 1.50E-02 1.37E+OO 1.19E-01 1.50E-02 1.41 E+OO 1.42E-01 2.30E-02 1.97E+OO 2.26E-01 2.30E-02 1.39E+OO 1.09E-01 2.30E-02 1.44E+OO 1.10E-01 3.50E-02 2.05E+OO 3.12E-01 3.50E-02 1.40E+OO 1.46E-01 3.50E-02 1.48E+OO 2.10E-01 5.50E-02 2.22E+OO 1.77E-01 5.50E-02 1.45E+OO 1.65E-01 5.50E-02 1.60E+OO 1.75E-01 7.00E-02 2.31E+OO 3.48E-01 7.00E-02 1.49E+OO 1.61 E-01 7.00E-02 1.71 E+OO 2.48E-01 1.00E-01 2.44E+OO 2.02E-01 1.00E-01 1.56E+OO 2.40E-01 1.00E-01 1.89E+OO 3.43E-01 1.30E-01 2.46E+OO 2.60E-01 1.30E-01 1.64E+OO 2.26E-01 1.30E-01 2.09E+OO 3.00E-01 1.70E-01 2.19E+OO 3.79E-01 1.70E-01 1.75E+OO 2.55E-01 1.70E-01 2.31E+OO 2.92E-01 3.00E-01 1.58E+OO 6.31E-01 3.00E-01 2.15E+OO 3.17E-01 3.00E-01 2.72E+OO 2.75E-01 Profile C - Sand Set 0.5Hz Median Sigma PSA (g)

AF ln(AF) 1.40E-03 1.22E+OO 6.05E-02 5.00E-03 1.23E+OO 7.61E-02 1.50E-02 1.25E+OO 9.25E-02 2.30E-02 1.26E+OO 8.13E-02 3.50E-02 1.27E+OO 7.53E-02 5.50E-02 1.33E+OO 1.80E-01 7.00E-02 1.38E+OO 1.36E-01 1.00E-01 1.46E+OO 3.53E-01 1.30E-01 1.58E+OO 2.23E-01 1.70E-01 1.75E+OO 2.47E-01 3.00E-01 2.27E+OO 3.00E-01