ML15189A235
ML15189A235 | |
Person / Time | |
---|---|
Site: | Browns Ferry |
Issue date: | 05/26/2015 |
From: | Thompson R Tennessee Valley Authority |
To: | Steve Wyman Japan Lessons-Learned Division |
References | |
Download: ML15189A235 (19) | |
Text
NRR-PMDAPEm Resource From: Thompson, Russell R [rrthompson@tva.gov]
Sent: Tuesday, May 26, 2015 11:12 AM To: Wyman, Stephen Cc: DiFrancesco, Nicholas
Subject:
Advanced Response - BFN ESEP Clarifying Questions Attachments: Advanced Response - BFN ESEP Clarifying Questions.docx; Attachment - BFN Elevation Reference.xlsx Attached are the advanced responses to the clarifying questions on the BFN ESEP.
The formal response will be submitted in the near future.
Please call me if you have any questions.
Russell Thompson Corporate Nuclear Licensing W: 423/751-2567 C: 423/593-1831 This electronic message transmission contains information which may be TVA SENSITIVE, TVA RESTRICTED or TVA CONFIDENTIAL.
Any misuse or unauthorized disclosure can result in both civil and criminal penalties. If you are not the intended recipient, be aware that any disclosure, copying, distribution or use of the content of this information is prohibited. If you have received this communication in error, please notify me immediately by email and delete the original message.
1
Hearing Identifier: NRR_PMDA Email Number: 2193 Mail Envelope Properties (8413227FF24DB5489D86AE8EF8ADCAFE2C2918E2)
Subject:
Advanced Response - BFN ESEP Clarifying Questions Sent Date: 5/26/2015 11:11:45 AM Received Date: 5/26/2015 11:11:51 AM From: Thompson, Russell R Created By: rrthompson@tva.gov Recipients:
"DiFrancesco, Nicholas" <Nicholas.DiFrancesco@nrc.gov>
Tracking Status: None "Wyman, Stephen" <Stephen.Wyman@nrc.gov>
Tracking Status: None Post Office: TVACHAXCH8.main.tva.gov Files Size Date & Time MESSAGE 766 5/26/2015 11:11:51 AM Advanced Response - BFN ESEP Clarifying Questions.docx 28252 Attachment - BFN Elevation Reference.xlsx 26422 Options Priority: Standard Return Notification: No Reply Requested: No Sensitivity: Normal Expiration Date:
Recipients Received:
Browns Ferry ESEP Clarifying Questions
- 1) Section 3.2 of EPRI 3002000704 stated that The selection process for the ESEL should assume the FLEX strategies (modifications, equipment, procedures, etc.) have been implemented. The staff noted that not all non-portable FLEX components have been installed during the development of the licensees ESEP. Clarify whether HCLFP evaluations will be performed to ensure they achieve the RLGM capacity when those non-portable FLEX components are installed in the future and propose any following actions Response: In accordance with ESEP requirements, pre-staged FLEX equipment that is not anchored or connected to electrical or fluid systems is treated as non-installed equipment and evaluated primarily as an interaction concern for the plant. Pre-staged FLEX equipment that is anchored in the plant is treated as installed equipment and if required for the success of the FLEX strategy is evaluated using the ESEP criteria. This is true for FLEX equipment that was installed prior to ESEP submittal and is true for FLEX equipment installed after ESEP submittal.
- 2) Provide the justification why the following components are not included in the ESEL for Units 1,2 & 3:
- FCV-64-18, 19, 20, 21, FSV 84-8B & 8C, and FCV 76-19 & 24 for each unit (These valves may need to be closed for the Hardened Containment Venting Systems (HCVS) to work)
- HCVS Instrumentation such as those for process temperature
- Breaker, such as 1-BKR-071-0019, for MOVs
Response
Component Resolution Valve FCV-64-18 is an eighteen-inch diameter, air-operated, butterfly valve used for primary containment isolation (FSAR Table 5.2-2). This valve is normally closed and the desired FLEX state is for the valve to stay closed. The valve requires air to open and will spring closed,therefore a spurious opening of the valve will not occur. This approach is supported by the EPRI 3002000704 NTTF 2.1 Seismic Augmented FCV-64-18 Approach Guideline Questions & Answers, which states The only Containment Isolation Valves (CIVs) which would be included in the ESEL are those which need to be manipulated as part of implementing a Phase 1 or 2 FLEX strategy.In summary, this item was not included on the ESEL because the valve is normally closed and does not need to change state or be manipulated for Phase 1 or Phase 2 FLEX strategy.
Valve FCV-64-19 is a twenty-inch diameter, air-operated, butterfly valve used for primary containment isolation (FSAR Table 5.2-2). This valve is normally closed and the desired FLEX state is for the valve to stay closed. The valve requires air to open FCV-64-19 and will spring closed, therefore a spurious opening of the valve will not occur. This approach is supported by the EPRI 3002000704 NTTF 2.1 Seismic Augmented Approach Guideline Questions & Answers, which states The only Containment
Component Resolution Isolation Valves (CIVs) which would be included in the ESEL are those which need to be manipulated as part of implementing a Phase 1 or 2 FLEX strategy.In summary, this item was not included on the ESEL because the valve is normally closed and does not need to change state orbe manipulated for Phase 1 or Phase 2FLEX strategy.
Valve FCV-64-20 is a twenty-inch diameter, air-operated butterfly valve used for primary containment isolation (FSAR Table 5.2-2). This valve is normally closed and the desired FLEX state is for the valve to stay closed. The valve will spring open and requires air to close; therefore, a spurious opening of the valve could possibly occur with loss of service air. Manual action can be used to keep the valve closed. However, containment isolation would still be accomplished by the check valve that is located FCV-64-20 within the flow path, (DWG 47E610-64-1), regardless of the state of FCV-64-20.
Rather than credit valve FCV-64-20 and the air accumulator needed to keep the valve closed, the associated check valve CKV-064-0800 was selected as the success path for this containment isolation function.
In accordance with the Seismic Evaluation Guidance - Augmented Approach for the Resolution of the Fukushima Near-Term Task Force Recommendation 2.1 - Seismic, Section 3.2, the check valve was excluded from the ESEL.
Valve FCV-64-21 is a twenty-inch diameter, air-operated butterfly valve used for primary containment isolation. (FSAR Table 5.2-2). This valve is normally closed and the desired FLEX state is for the valve to stay closed. The valve will spring open and requires air to close; therefore, a spurious opening of the valve could possibly occur with loss of service air. Manual action can be used to keep the valve closed. However, containment isolation would still be accomplished by the check valve that is located FCV-64-21 within the flow path, (DWG 47E610-64-1), regardless of the state of FCV-64-21.
Rather than credit valve FCV-64-21 and the air accumulator needed to keep the valve closed, the associated check valve CKV-064-0801 was selected as the success path for this containment isolation function.
In accordance with the Seismic Evaluation Guidance - Augmented Approach for the Resolution of the Fukushima Near-Term Task Force Recommendation 2.1 - Seismic, Section 3.2, the check valve was excluded from the ESEL.
Valve FSV-84-8B is atwo-inch diameter, solenoid-operated, globe valve used for primary containment isolation (FSAR Table 5.2-2). This valve is normally closed and the desired FLEX state is for the valve to stay closed. The valve requires AC power to open and will spring closed, therefore a spurious opening of the valve will not occur.
This approach is supported by the EPRI 3002000704 NTTF 2.1 Seismic Augmented FSV-84-8B Approach Guideline Questions & Answers, which states The only Containment Isolation Valves (CIVs) which would be included in the ESEL are those which need to be manipulated as part of implementing a Phase 1 or 2 FLEX strategy.In summary, this item was not included on the ESEL because the valve is normally closed and does not need to change stateor be manipulated for Phase 1 or Phase 2FLEX strategy.
Valve FSV-84-8C is atwo-inch diameter, solenoid-operated, globe valve used for primary containment isolation (FSAR Table 5.2-2). This valve is normally closed and the desired FLEX state is for the valve to stay closed. The valve requires AC power to open and will spring closed therefore a spurious opening of the valve will not occur.
FSV-84-8C This approach is supported by the EPRI 3002000704 NTTF 2.1 Seismic Augmented Approach Guideline Questions & Answers, which states The only Containment Isolation Valves (CIVs) which would be included in the ESEL are those which need to be manipulated as part of implementing a Phase 1 or 2 FLEX strategy.In summary, this item was not included on the ESEL because the valve is normally closed and does
Component Resolution not need to change stateor be manipulated for Phase 1 or Phase 2FLEX strategy.
Valve FCV-76-19 is atwo-inch diameter, air-operated, butterfly valve used for primary containment isolation (FSAR Table 5.2-2). This valve is normally closed and the desired FLEX state is for the valve to stay closed. The valve requires air to open and will spring closed, therefore a spurious opening of the valve will not occur.
This approach is supported by the EPRI 3002000704 NTTF 2.1 Seismic Augmented FCV-76-19 Approach Guideline Questions & Answers, which states The only Containment Isolation Valves (CIVs) which would be included in the ESEL are those which need to be manipulated as part of implementing a Phase 1 or 2 FLEX strategy.In summary, this item was not included on the ESEL because the valve is normally closed and does not need to change state or be manipulated for Phase 1 or Phase 2 FLEX strategy.
Valve FCV-76-24 is a ten-inch diameter, air-operated, butterfly valve used for primary containment isolation (FSAR Table 5.2-2). This valve is normally closed and the desired FLEX state is for the valve to stay closed. The valve requires air to open and will spring closed, therefore a spurious opening of the valve will not occur. This approach is supported by the EPRI 3002000704 NTTF 2.1 Seismic Augmented FCV-76-24 Approach Guideline Questions & Answers, which states The only Containment Isolation Valves (CIVs) which would be included in the ESEL are those which need to be manipulated as part of implementing a Phase 1 or 2 FLEX strategy.In summary, this item was not included on the ESEL because the valve is normally closed and does not need to change state or be manipulated for Phase 1 or Phase 2 FLEX strategy.
ESEL instrumentation currently includes drywell pressure, drywell temperature, torus temperature and torus level. The components included are those presented in the BFN Overall Integrated Plan (OIP) for containment HCVS Instrumentation control. Seismic Evaluation Guidance - Augmented Approach for the Resolution of the Fukushima Near-Term Task Force Recommendation 2.1, Table 3-1 provides containment pressure, suppression pool temperature,and suppression pool level as parameters required for containment control.
Breakers in MCCs or busses are treated as rule of the box. This is consistent with the MOV Breakers EPRI 3002000704 NTTF 2.1 Seismic Augmented Approach Guideline Questions &
Answers,
However, the control point for the IPEEE RLE is not discussed. In order to confirm that the control point of the IPEEE RLE is at the same location as the GMRS, provide the IPEEE RLE control point.
Response: The IPEEE RLE control point is the same as the SSE control point and GMRS control point.
- 4) Section 6.2 of the ESEP Report describes ESEL component screening using Table 2-4 of EPRI NP-6041-SL. This table is applicable to components located up to 40 ft above grade. The ESEP report is silent concerning screening or HCLPF calculations at
elevations beyond 40 ft above grade. Therefore, describe how ESEL components located at elevations beyond 40 ft above grade either were screened or had their HCLPF capacities calculated, including specific references for the applicable guidance utilized.
Response: Effective Grade at BFN is at approximately 550 ft. as shown in TVA Calculation CDQ0000940339. Components located above elevation 590 ft. are included in the attached table. Most components were evaluated in the earlier A-46 or seismic IPEEE program and are indicated as such. For components above base elevation, the Table 2-4 of EPRI NP-6041-SL screening capacities were conservatively interpreted as applicable for comparison with in-structure response spectra (ISRS). That is, the 5% damped spectral acceleration capacity was taken as 1.2g for the center capacity column of Table 2-4 of EPRI NP-6041 SL, and used for comparison to ISRS. Note that according to Section B.2 of EPRI 1019200 (Seismic Fragility Applications Guide Update), the appropriate capacity for the center capacity column of Table 2-4 of EPRI NP-6041 SL should be increased to 1.8g for comparison with clipped ISRS. This was done for ESEP.The additional HCLPF evaluations are performed in TVA Calculation CDQ0009992014000268.
- 5) Section 6.3.3 of the ESEP report indicates that HCLPF capacity evaluations were recommended for 12 components; however, the results for a number of these components could not be identified in the text portion of the report or the HCLPF table, e.g., main control room benchboard, blocks walls, Terry turbine control box, RCIC Back-Up Control Panel, and LPNL Instrument Rack. Please provide the HCLPF values and failure modes for those items.
Response: The requested information is documented in TVA Calculation CDQ0009992014000268, Rev. 02. Results are as follows:
HCLPF Capacity Failure Description for RLE at Mode Rock Outcrop Main Control Room Benchboard 0.62g Functional Block Walls >0.30g Structural Integrity and Anchorage (per 80-11 program)
Terry Turbine Control Box (controls) 0.85g Functional RCIC Back-up Control Panel 0.62g Functional LPNL Instrument Rack 0.74g Anchorage
- 6) The licensee reported that the ESEL items included in the IPEEE program are screened out based on previous evaluations against the IPEEE RLE which envelops the ESEP
RLGM for frequencies between 1 and 10 Hz and on recent walk-by verifications.
Section 6.4 of the ESEP report states that the ESEL items not included in the IPEEE program are evaluated using the criteria in EPRI NP6041SL. Section 5.2 of the ESEP report states that The RLGM ISRS for the Browns Ferry Nuclear Plant are generated by scaling the design basis SSE up to 0.3 g RLE as determined in the Seismic IPEEE.
Please clarify if the licensee evaluated ESEL items not included in the IPEEE program using the ISRS developed by scaling the SSE up to the IPEEE RLE with a PGA of 0.3 g, instead of the ESEP RLGM with a PGA of 0.4 g, and, if so, provide the justification.
Response: ESEL items not included in the IPEEE program were evaluated using the ISRS developed by scaling the SSE up to the IPEEE RLE with a PGA of 0.3g. It is appropriate to use the IPEEE RLE with a PGA of 0.3g because that spectra envelops the ESEP RLGM with a PGA of 0.4g in the 1-10 Hz range, which is the frequency range of interest. This is shown graphically in Figure 6-1 of the Browns Ferry Nuclear Plant ESEP Report.
- 7) Section 7.0 states that some components inside drywell were not accessible during the walk by verifications. Those components were later assessed by the licensees SRT to be free of seismic interaction concerns through the use of current photographs. Please specify the date(s) the photographs were taken.
Response: The photographs were observed on the Browns Ferry Video Tours Omnicast Web Viewer page at the recommendation of BFN Radiation Control personnel in the interest of ALARA considerations. The Drywell web page includes the note Last modified: 5/09/09. There is no date on the photographs.
Equipment ID Description A-46 IPEEE Building/Room EL RCIC Flow Indicating 1-FIC-71-36A N N U1 CB/ MCR 617' Controller Power Supply for RCIC flow 1-PX-71-36A N N U1 RB/ NW Corner 621' controller RCIC Auto Isol. Seal-In 1-13A-K15 N N U1 RB 621 Relay RCIC High Space 1-13A-K10 N N U1 RB 621 Temperature Relay RCIC High Space 1-13A-K11 N N U1 RB 621 Temperature Relay RCIC Low Steam Supply 1-13A-K13 N N U1 RB 621 Press. Relay RCIC Steam Line High 1-2-71-K12 N N U1 RB 621 Differential Pressure Relay RCIC High Rupt. Disc Pres.
1-13A-K44 N N U1 RB 621 Relay RCIC High Rupt. Disc 1-13A-K45 N N U1 RB 621 Pres.Relay RCIC Auto Isol. Seal-In 1-13A-K12 N N U1 RB 621 Relay RCIC Auto Isol. Seal-In 1-13A-K14 N N U1 RB 621 Relay RCIC Auto Isol. Seal-In 1-13A-K16 N N U1 RB 621 Relay RCIC Manual Steam 1-13A-K38 N N U1 RB 621 Isolation RCIC Auto Discharge 1-13A-K17 N N U1 RB 621 Circuit Reset RCIC Auto Discharge 1-13A-K18 N N U1 RB 621 Circuit Reset RCIC Vessel Low Water 1-13A-K37 N N U1 RB 621 Lev.
RCIC Auto Isol. Seal-In 2-13A-K15 N N U2 RB 621 Relay RCIC High Space 2-13A-K10 N N U2 RB 621 Temperature Relay RCIC High Space 2-13A-K11 N N U2 RB 621 Temperature Relay RCIC Low Steam Supply 2-13A-K13 N N U2 RB 621 Press. Relay RCIC Steam Line High 2-2-71-K12 N N U2 RB 621 Differential Pressure Relay RCIC High Rupt. Disc Pres.
2-13A-K44 N N U2 RB 621 Relay RCIC High Rupt. Disc 2-13A-K45 N N U2 RB 621 Pres.Relay RCIC Auto Isol. Seal-In 2-13A-K12 N N U2 RB 621 Relay RCIC Auto Isol. Seal-In 2-13A-K14 N N U2 RB 621 Relay
RCIC Auto Isol. Seal-In 2-13A-K16 N N U1 RB 621 Relay RCIC Manual Steam 2-13A-K38 N N U2 RB 621 Isolation RCIC Auto Discharge 2-13A-K17 N N U2 RB 621 Circuit Reset RCIC Auto Discharge 2-13A-K18 N N U2 RB 621 Circuit Reset RCIC Vessel Low Water 2-13A-K37 N N U2 RB 621 Lev.
RCIC Flow Indicating 2-FIC-71-36A N N U2 CB/ MCR 617' Controller Power Supply for RCIC flow 2-PX-71-36A N N U2 RB/ Q/R2 621' controller RCIC Flow Indicating 3-FIC-71-36A N N U3 CB/ MCR 617' Controller Power Supply for RCIC flow 3-PX-71-36A N N U3 RB/ Q/R2 621' controller RCIC Auto Isol. Seal-In 3-13A-K15 N N U3 RB 621 Relay RCIC High Space 3-13A-K10 N N U3 RB 621 Temperature Relay RCIC High Space 3-13A-K11 N N U3 RB 621 Temperature Relay RCIC Low Steam Supply 3-13A-K13 N N U3 RB 621 Press. Relay RCIC Steam Line High 3-2-71-K12 N N U3 RB 621 Differential Pressure Relay RCIC High Rupt. Disc Pres.
3-13A-K44 N N U3 RB 621 Relay RCIC High Rupt. Disc 3-13A-K45 N N U3 RB 621 Pres.Relay RCIC Auto Isol. Seal-In 3-13A-K12 N N U3 RB 621 Relay RCIC Auto Isol. Seal-In 3-13A-K14 N N U3 RB 621 Relay RCIC Auto Isol. Seal-In 3-13A-K16 N N U3 RB 621 Relay RCIC Manual Steam 3-13A-K38 N N U3 RB 621 Isolation RCIC Auto Discharge 3-13A-K17 N N U3 RB 621 Circuit Reset RCIC Auto Discharge 3-13A-K18 N N U3 RB 621 Circuit Reset RCIC Vessel Low Water 3-13A-K37 N N U3 RB 621 Lev.
1-PCV 1-4 Control room 1-HS-1-4 Y Y U1 CB/ MCR 617' hand switch Transfer Switch for 2-PCV-2-XS-1-4 N N U1-RB 621 1-4 1-PCV 1-5 Control room 1-HS-1-5A Y Y U1 CB/ MCR 617' hand switch Transfer Switch for 1-PCV-1-XS-1-5 N N U1-RB 621 1-5
1-PCV 1-18 Control room 1-HS-1-18 Y Y U1 CB/ MCR 617' hand switch 1-PCV 1-19 Control room 1-HS-1-19A Y Y U1 CB/ MCR 617' hand switch 1-PCV 1-22 Control room 1-HS-1-22A Y Y U1 CB/ MCR 617' hand switch Transfer Switch for 2-PCV-1-XS-1-22 N N U1-RB 621 1-22A 1-PCV 1-23 Control room 1-HS-1-23A Y Y U1 CB/ MCR 617' hand switch Transfer Switch for 2-PCV-1-XS-1-232 N N U1-RB 621 1-23A 1-PCV 1-30 Control room 1-HS-1-30A Y Y U1 CB/ MCR 617' hand switch Transfer Switch for 1-PCV-1-XS-1-30 N N U1-RB 621 1-30A 1-PCV 1-31 Control room 1-HS-1-31A Y Y U1 CB/ MCR 617' hand switch 1-PCV 1-34 Control room 1-HS-1-34A Y Y U1 CB/ MCR 617' hand switch Transfer Switch for 1-PCV-1-XS-1-34 N N U1-RB 621 1-34 1-PCV 1-41 Control room 1-HS-1-41 Y Y U1 CB/ MCR 617' hand switch Transfer Switch for 1-PCV-1-XS-1-41 N N U1-RB 621 1-41 1-PCV 1-42 Control room 1-HS-1-42 Y Y U1 CB/ MCR 617' hand switch Transfer Switch for 1-PCV-1-XS-1-42 N N U1-RB 621 1-42 1-PCV 1-179 Control room 1-HS-1-179A Y Y U1 CB/ MCR 617' hand switch 1-PCV 1-180 Control room 1-HS-1-180A Y Y U1 CB/ MCR 617' hand switch Transfer Switch for 1-PCV-1-XS-1-180 N N U1-RB 621 1-180 1-XS-1-159A ADS inhibit Switch Y Y U1 CB/ MCR 617' 1-XS-1-161A ADS inhibit Switch Y Y U1 CB/ MCR 617' Local Panel 25-32: Backup 1-LPNL-925-0032 Y Y U1 RB/ Q/R2 621' Control 1-PCV 1-4 Control room 2-HS-1-4 Y Y U2 CB/ MCR 617' hand switch Transfer Switch for 2-PCV-2-XS-1-4 N N U2-RB 621 1-4 1-PCV 1-5 Control room 2-HS-1-5A Y Y U2 CB/ MCR 617' hand switch Transfer Switch for 1-PCV-2-xS-1-5 N N U2-RB 621 1-5 1-PCV 1-18 Control room 1-HS-1-18 Y Y U2 CB/ MCR 617' hand switch 1-PCV 1-19 Control room 1-HS-1-19A Y Y U2 CB/ MCR 617' hand switch 1-PCV 1-22 Control room 1-HS-1-22A Y Y U2 CB/ MCR 617' hand switch
Transfer Switch for 2-PCV-2-XS-1-22 N N U2-RB 621 1-22A 1-PCV 1-23 Control room 1-HS-1-23A Y Y U2 CB/ MCR 617' hand switch Transfer Switch for 2-PCV-2-xS-1-232 N N U2-RB 621 1-23A 1-PCV 1-30 Control room 1-HS-1-30A Y Y U2 CB/ MCR 617' hand switch Transfer Switch for 1-PCV-2-xS-1-30 N N U2-RB 621 1-30A 1-PCV 1-31 Control room 1-HS-1-31A Y Y U2 CB/ MCR 617' hand switch 1-PCV 1-34 Control room 1-HS-1-34A Y Y U2 CB/ MCR 617' hand switch Transfer Switch for 1-PCV-2-XS-1-34 N N U2-RB 621 1-34 1-PCV 1-41 Control room 1-HS-1-41 Y Y U2 CB/ MCR 617' hand switch Transfer Switch for 1-PCV-2-XS-1-41 N N U2-RB 621 1-41 1-PCV 1-42 Control room 1-HS-1-42 Y Y U2 CB/ MCR 617' hand switch Transfer Switch for 1-PCV-2-xS-1-42 N N U2-RB 621 1-42 1-PCV 1-179 Control room 1-HS-1-179A Y Y U2 CB/ MCR 617' hand switch 1-PCV 1-180 Control room 1-HS-1-180A Y Y U2 CB/ MCR 617' hand switch Transfer Switch for 1-PCV-2-XS-1-180 N N U2-RB 621 1-180 2-XS-1-159A ADS inhibit Switch Y Y U2 CB/ MCR 617' 2-XS-1-161A ADS inhibit Switch Y Y U2 CB/ MCR 617' Local Panel 25-32: Backup 1-LPNL-925-0032 Y Y U2 RB/ Q/R2 621' Control 1-PCV 1-4 Control room 3-HS-1-4 Y Y U3 CB/ MCR 617' hand switch Transfer Switch for 3-PCV-3-XS-1-4 N N U3-RB 621 1-4 1-PCV 1-5 Control room 3-HS-1-5A Y Y U3 CB/ MCR 617' hand switch Transfer Switch for 1-PCV-3-XS-1-5 N N U3-RB 621 1-5 1-PCV 1-18 Control room 3-HS-1-18 Y Y U3 CB/ MCR 617' hand switch 1-PCV 1-19 Control room 3-HS-1-19A Y Y U3 CB/ MCR 617' hand switch 1-PCV 1-22 Control room 3-HS-1-22A Y Y U3 CB/ MCR 617' hand switch Transfer Switch for 3-PCV-3-XS-1-22 N N U3-RB 621 1-22A 1-PCV 1-23 Control room 3-HS-1-23A Y Y U3 CB/ MCR 617' hand switch Transfer Switch for 3-PCV-3-XS-1-23 N N U3-RB 621 1-23A
1-PCV 1-30 Control room 3-HS-1-30A Y Y U3 CB/ MCR 617' hand switch Transfer Switch for 1-PCV-3-XS-1-30 N N U3-RB 621 1-30A 1-PCV 1-31 Control room 3-HS-1-31A Y Y U3 CB/ MCR 617' hand switch 1-PCV 1-34 Control room 3-HS-1-34A Y Y U3 CB/ MCR 617' hand switch Transfer Switch for 1-PCV-3-XS-1-34 N N U3-RB 621 1-34 1-PCV 1-41 Control room 3-HS-1-41 Y Y U3 CB/ MCR 617' hand switch Transfer Switch for 1-PCV-3-XS-1-41 N N U3-RB 621 1-41 1-PCV 1-42 Control room 3-HS-1-42 Y Y U3 CB/ MCR 617' hand switch Transfer Switch for 1-PCV-3-XS-1-42 N N U3-RB 621 1-42 1-PCV 1-179 Control room 3-HS-1-179A Y Y U3 CB/ MCR 617' hand switch 1-PCV 1-180 Control room 3-HS-1-180A Y Y U3 CB/ MCR 617' hand switch Transfer Switch for 1-PCV-3-XS-1-180 N N U3-RB 621 1-180 3-XS-1-159A ADS inhibit Switch Y Y U3 CB/ MCR 617' 3-XS-1-161A ADS inhibit Switch Y Y U3 CB/ MCR 617' Local Panel 25-32: Backup 1-LPNL-925-0032 Y Y U3 RB/ Q/R2 621' Control 1-LI-3-58B RPV Level Instrument Y N U1 CB/ MCR 617' RPV Shutdown Floodup 1-LI-3-55 N Y U1 CB/Main Cont Rm 617' Range 1-PI-3-74B RPV Pressure Indicator Y Y U1 CB/Main Cont Rm 617' Drywell Temperature 1-TIS-64-52AA Y Y U1 RB 621 Indicator Switch Drywell Temperature 1-TI-64-52AB Y Y U1 CB/Main Cont Rm 617 Indicator 1-PI-064-67B Drywell Pressure Indicator Y Y U1 CB/Main Cont Rm 617' Suppression Pool Level 1-LI-064-159A N Y U1 CB/ MCR 617' Indicator (Div II)
Torus Bulk Water 1-TI-064-161 Y N U1 CB/ MCR 617' Temperature (Div I)
REACTOR SD & CONT.
1-PNLA-009-0003A Y Y U1 CB/ MCR 617' COOLING PNL REACTOR SD & CONT.
1-PNLA-009-0003B Y Y U1 CB/ MCR 617' COOLING PNL I&C Bus 1A and 1B 1-PNLA-009-009 (Cabinet 2 and 3 of panel 1- Y Y U1 CB/ MCR 617' 9-9) 1PNLA9250031 Local Panel 25-31 Y Y U1 RB/ Q/R2 621' 2-LI-3-58B RPV Level Instrument Y N U2 CB/ MCR 617' 2-LI-3-55 RPV Shutdown Floodup Rang N Y U2 CB/Main Cont Rm 617' 2-PI-3-74B RPV Pressure Indicator Y Y U2 CB/ MCR 617' 2-TIS-64-52AA well Temperature Indicator Sw Y Y U2 RB 621
2-TI-64-52AB Drywell Temperature Indicato Y Y U2 CB/Main Cont Rm 617 2-PI-064-67B Drywell Pressure Indicator Y Y U2 CB/ MCR 617' Suppression Pool Level 2-LI-064-159A Y N U2 CB/ MCR 617' Indicator (Div II)
Torus Bulk Water 2-TI-064-161 Y N U2 CB/ MCR 617' Temperature (Div I)
REACTOR SD & CONT.
2-PNLA-009-0003A Y Y U2 CB/ MCR 617' COOLING PNL REACTOR SD & CONT.
2-PNLA-009-0003B Y Y U2 CB/ MCR 617' COOLING PNL I&C Bus 1A and 1B 2-PNLA-009-009 (Cabinet 2 and 3 of panel 1- Y Y U2 CB/ MCR 617' 9-9) 2PNLA9250031 Local Panel 25-31 Y Y U2 RB/ Q/R2 621' 3-LI-3-58B RPV Level Instrument Y N U3 CB/ MCR 617' 3-LI-3-55 RPV Shutdown Floodup Rang N Y U3 CB/Main Cont Rm 617' 3-PI-3-74B RPV Pressure Indicator Y Y U2 CB/ MCR 617' 3-TIS-64-52AA well Temperature Indicator Sw Y Y U3 RB 621 3-TI-64-52AB Drywell Temperature Indicato Y Y U3 CB/Main Cont Rm 617 3-PI-064-67B Drywell Pressure Indicator Y Y U31 CB/Main Cont Rm 617' Suppression Pool Level 3-LI-064-159A Y N U3 CB/ MCR 617' Indicator (Div II)
Torus Bulk Water 3-TI-064-161 Y N U3 CB/ MCR 617' Temperature (Div I)
REACTOR SD & CONT.
3-PNLA-009-0003A Y Y U3 CB/ MCR 617' COOLING PNL REACTOR SD & CONT.
3-PNLA-009-0003B Y Y U3 CB/ MCR 617' COOLING PNL I&C Bus 1A and 1B 3-PNLA-009-009 (Cabinet 2 and 3 of panel 1- Y Y U3 CB/ MCR 617' 9-9) 3PNLA9250031 Local Panel 25-31 Y Y U3 RB/ Q/R2 621' 1-BDBB-281-0001A 250V RMOV Board 1A Y Y U1 RB/ Q/R1 621' 2-BDBB-281-0002A 250V RMOV Board 2A Y Y U2 RB/ Q/R14 621' 3-BDBB-281-0003A 250V RMOV Board 3A Y Y U3 RB/ SD BD E 621' 250V DISTRIBUTION 0-PNLA-248-A Y Y U1 RB/ S/R2 621' PANEL SB-A 0-BATA-248-0000A 250V BATTERY SB-A Y Y U1 RB/ S/R2 621' 250V BATTERY 0-CHGA-248-0000A Y Y U1 RB/ S/R2 621' CHARGER SB-A 250V DISTRIBUTION 0-PNLA-248-B Y Y U1 RB/ S/R2 621' PANEL SB-B 0-BATA-248-0000B 250V BATTERY SB-B Y Y U1 RB/ S/R2 621' 250V BATTERY 0-CHGA-248-0000B Y Y U2 RB/ S/R2 621' CHARGER SB-B 0-BATA-248-0000C 250V BATTERY SB-C Y Y U2 RB/ S/R13 621' 250V DISTRIBUTION 0-PNLA-248-0000C Y Y U2 RB/ S/R13 621' PANEL SB-C 250V BATTERY 0-CHGA-248-0000C Y Y U2 RB/ S/R13 621' CHARGER SB-C 0-BATA-248-0000D 250V BATTERY SB-D Y Y U1 RB/ S/R13 621'
250V DISTRIBUTION 0-PNLA-248-0000D Y Y U2 RB/ S/R13 621' PANEL SB-D 250V BATTERY 0-CHGA-248-0000D Y Y U2 RB/ S/R13 621' CHARGER SB-D 1-BDBB-231-0001A 480 V SD Board 1A Y Y U1 RB/ S/R1 621' 1-BDBB-231-0001B 480 V SD Board 1B Y Y U1 RB/ S/R2 621' 2-BDBB-231-0002A 480 V SD Board 2A Y Y U2 RB/ S/R13 621' 2-BDBB-231-0002B 480 V SD Board 2B Y Y U2 RB/ S/R14 621' 3-BDBB-231-0003A 480 V SD Board 3A Y Y U3 RB/ S/R20 621' 3-BDBB-231-0003B 480 V SD Board 3B Y Y U3 RB/ R/R1 621' 1-BDBB-268-0001A 480 V RMOV Board 1A Y Y U1 RB/ R/R1 617' 2-BDBB-268-0002A 480 V RMOV Board 2A Y Y U2 RB/ R/R14 621' 3-BDBB-268-0003A 480 V RMOV Board 3A Y Y U3 RB/ SD BD F 621' 0-BDAA-211-0000A 4 kV Shutdown Board A Y Y U1 RB 621 0-BDAA-211-0000C 4 kV Shutdown Board C Y Y U2 RB 621 1-XFA-231-TS1A 4KV/480 Trans. TS1A Y Y U1 RB 621 1-XFA-231-TS1B 4KV/480 Trans. TS1A Y Y U1 RB 621 2-XFA-231-TS2A 4KV/480 Trans. TS2A Y Y U2 RB 621 2-XFA-231-TS2B 4KV/480 Trans. TS2B Y Y U2 RB 621 3-XFA-231-TS2A 4KV/480 Trans. TS2A Y Y U3 RB 621 3-XFA-231-TS2B 4KV/480 Trans. TS2B Y Y U3 RB 621 3-XFA-231-TS1E 4KV/480 Trans. TS1E Y Y U3 RB 621 RCIC Steam Line Space U1 CB 1-13A-K30 N N 593 Excess Temp. Isol. U1 Air RCIC Steam Line Space U1 CB 1-13A-K31 N N 593 Excess Temp. Isol. U1 Air RCIC Steam Line Space U1 CB 1-71-K32 N N 593 Excess Temp. Isol. U1 Air 1-13A-K32 team Line Space Excess Tem N N U1 CB U1 Air 593 RCIC Steam Line Space U1 CB 1-13A-K33 N N 593 Excess Temp. Isol. U1 Air RCIC Steam Line Space U2 CB 2-13A-K30 N N 593 Excess Temp. Isol. U2 Air RCIC Steam Line Space U2 CB 2-13A-K31 N N 593 Excess Temp. Isol. U2 Air RCIC Steam Line Space U2 CB 2-71-K32 N N 593 Excess Temp. Isol. U2 Air 3-13A-K33 RCIC Auto Isol. Signal N N U3 CB U3 Air 593 RCIC Steam Line Space U2 CB 2-13A-K33 N N 593 Excess Temp. Isol. U2 Air RCIC Steam Line Space U3 CB 3-13A-K30 N N 593 Excess Temp. Isol. U3 Air RCIC Steam Line Space U3 CB 3-13A-K31 N N 593 Excess Temp. Isol. U3 Air RCIC Steam Line Space U3 CB 1-71-K32 N N 593 Excess Temp. Isol. U3 Air 3-13A-K32 team Line Space Excess Tem N N U3 CB U1 Air 593 RCIC Steam Line Space U3 CB 3-13A-K33 N N 593 Excess Temp. Isol. U3 Air Transfer Switch for 1-PCV-1-XS-1-18 N N Control Bay 1c 593' 1-18
Transfer Switch for 1-PCV-1-XS-1-19 N N Control Bay 1c 593 1-19A Transfer Switch for 1-PCV-1-XS-1-31 N N Control Bay 1c 593 1-30A Transfer Switch for 1-PCV-1-XS-1-179 N N Control Bay 1c 593 1-179 Transfer Switch for 1-PCV-2-xS-1-18 N N Control Bay 1c 593' 1-18 Transfer Switch for 1-PCV-2-XS-1-19 N N Control Bay 1c 593 1-19A Transfer Switch for 1-PCV-2-XS-1-31 N N Control Bay 1c 593 1-30A Transfer Switch for 1-PCV-2-XS-1-179 N N Control Bay 1c 593 1-179 Transfer Switch for 1-PCV-3-XS-1-18 N N Control Bay 1c 593' 1-18 Transfer Switch for 1-PCV-3-XS-1-19 N N Control Bay 1c 593 1-19A Transfer Switch for 1-PCV-3-XS-1-31 N N Control Bay 1c 593 1-30A Transfer Switch for 1-PCV-3-XS-1-179 N N Control Bay 1c 593 1-179 RPV Level Indication /
1-LIS-3-58B Switch N N U1 CB/ U1 AIR 593' 1-LS-3-58B RPV Level Switch N N U1 CB/ U1 AIR 593' RPV Shutdown Floodup 1-LT-3-55 N N U1 RB 593 Range RPV Pressure Indication /
1-PIS-3-74B Switch Y Y U1 CB/ Unit 1 AIR 593' 1-PT-3-74B RPV Pressure Transmitter Y Y U1 RB/ P/R5 593' 1-PT-064-67 Drywell Pressure Transmitter Y Y U1 RB/ S/R3 593' Torus temperature module 1-TM-64-161A A Y N U1 CB/ U1 AIR 593' Torus temperature module 1-TM-64-161B B Y N U1 CB/ U1 AIR 593' Torus temperature module 1-TM-64-161C C Y N U1 CB/ U1 AIR 593' Torus temperature module 1-TM-64-161D D Y N U1 CB/ U1 AIR 593' Torus temperature module 1-TM-64-161E E Y N U1 CB/ U1 AIR 593' Torus temperature module 1-TM-64-161F F Y N U1 CB/ U1 AIR 593' Torus temperature module 1-TM-64-161G G Y N U1 CB/ U1 AIR 593' Torus temperature module 1-TM-64-161H H Y N U1 CB/ U1 AIR 593' Torus temperature module 1-TM-64-161J J Y N U1 CB/ U1 AIR 593' Torus temperature module 1-TM-64-161K K Y N U1 CB/ U1 AIR 593' Torus temperature module 1-TM-64-161L L Y N U1 CB/ U1 AIR 593'
1PNLA0090032 RCIC, ADS PNL Y Y U1 CB/ U1 AIR 593' RHR, CS, HPCI (CH B),
1-PNLA-009-0033 RCIC, ADS Logic PNL Y Y U1 CB/ U1 AIR 593' 1-PNLA-009-0081 DIV I ECCS ATU CABINET Y Y U1 CB/ U1 AIR 593' DIV II ECCS ATU 1-PNLA-009-0082 CABINET Y Y U1 CB/ U1 AIR 593' DIV I TORUS TEMP 1-PNLA-009-0087 MONITORING Y Y U1 CB/ U1 AIR 593' 1-LPNL-925-005A LOCAL PANEL 25-5A Y Y U1 RB/ S/R3 593' 1-LPNL-925-005B LOCAL PANEL 25-5B Y Y U1 RB/ S/R3 593' RPV Level Indication /
2-LIS-3-58B Switch N N U2 CB/ U2 AIR 593' 2-LS-3-58B RPV Level Switch N N U2 CB/ U2 AIR 593' 2-LT-3-55 RPV Shutdown Floodup Rang N N U2 RB 593 RPV Pressure Indication /
2-PIS-3-74B Switch Y Y U2 CB/ Unit 1 AIR 593' 2-PT-3-74B RPV Pressure Transmitter Y Y U2 RB/ P/R5 593' 2-PT-064-67B Drywell Pressure Transmitter Y Y U2 RB/ S/R3 593' Torus temperature module 2-TM-64-161A A Y N U2 CB/ U2 AIR 593' Torus temperature module 2-TM-64-161B B Y N U2 CB/ U2 AIR 593' Torus temperature module 2-TM-64-161C C Y N U2 CB/ U2 AIR 593' Torus temperature module 2-TM-64-161D D Y N U2 CB/ U2 AIR 593' Torus temperature module 2-TM-64-161E E Y N U2 CB/ U2 AIR 593' Torus temperature module 2-TM-64-161F F Y N U2 CB/ U2 AIR 593' Torus temperature module 2-TM-64-161G G Y N U2 CB/ U2 AIR 593' Torus temperature module 2-TM-64-161H H Y N U2 CB/ U2 AIR 593' Torus temperature module 2-TM-64-161J J Y N U2 CB/ U2 AIR 593' Torus temperature module 2-TM-64-161K K Y N U2 CB/ U2 AIR 593' Torus temperature module 2-TM-64-161L L Y N U2 CB/ U2 AIR 593' RHR, CS, HPCI (CH A),
2PNLA0090032 RCIC, ADS PNL Y Y U2 CB/ U2 AIR 593' RHR, CS, HPCI (CH B),
2-PNLA-009-0033 RCIC, ADS Logic PNL Y Y U2 CB/ U2 AIR 593' 2-PNLA-009-0081 DIV I ECCS ATU CABINET Y Y U2 CB/ U2 AIR 593' DIV II ECCS ATU 2-PNLA-009-0082 CABINET Y Y U2 CB/ U2 AIR 593' DIV I TORUS TEMP 2-PNLA-009-0087 MONITORING Y Y U2 CB/ U2 AIR 593'
2-LPNL-925-005A LOCAL PANEL 25-5A Y Y U2 RB/ S/R3 593' 2-LPNL-925-005B LOCAL PANEL 25-5B Y Y U2 RB/ S/R3 593' RPV Level Indication /
3-LIS-3-58B Switch N N U3 CB/ U3 AIR 593' 3-LS-3-58B RPV Level Switch N N U3 CB/ U3 AIR 593' 3-LT-3-55 RPV Shutdown Floodup Rang N N U3 RB 593 RPV Pressure Indication /
3-PIS-3-74B Switch Y Y U3 CB/ Unit 1 AIR 593' 3-PT-3-74B RPV Pressure Transmitter Y Y U213RB/ P/R5 593' 3-PT-064-67 Drywell Pressure Transmitter Y Y U31 RB/ S/R3 593' Torus temperature module 3-TM-64-161A A Y N U3 CB/ U3 AIR 593' Torus temperature module 3-TM-64-161B B Y N U3 CB/ U3 AIR 593' Torus temperature module 3-TM-64-161C C Y N U3 CB/ U3 AIR 593' Torus temperature module 3-TM-64-161D D Y N U3 CB/ U3 AIR 593' Torus temperature module 3-TM-64-161E E Y N U3 CB/ U3 AIR 593' Torus temperature module 3-TM-64-161F F Y N U3 CB/ U3 AIR 593' Torus temperature module 3-TM-64-161G G Y N U3 CB/ U3 AIR 593' Torus temperature module 3-TM-64-161H H Y N U3 CB/ U3 AIR 593' Torus temperature module 3-TM-64-161J J Y N U3 CB/ U3 AIR 593' Torus temperature module 3-TM-64-161K K Y N U3 CB/ U3 AIR 593' Torus temperature module 3-TM-64-161L L Y N U3 CB/ U3 AIR 593' RHR, CS, HPCI (CH A),
3PNLA0090032 RCIC, ADS PNL Y Y U3 CB/ U3 AIR 593' RHR, CS, HPCI (CH B),
3-PNLA-009-0033 RCIC, ADS Logic PNL Y Y U3 CB/ U3 AIR 593' 3-PNLA-009-0081 DIV I ECCS ATU CABINET Y Y U3 CB/ U3 AIR 593' DIV II ECCS ATU 3-PNLA-009-0082 CABINET Y Y U3 CB/ U3 AIR 593' DIV I TORUS TEMP 3-PNLA-009-0087 MONITORING Y Y U3 CB/ U3 AIR 593' 3-LPNL-925-005A LOCAL PANEL 25-5A Y Y U3 RB/ S/R3 593' 3-LPNL-925-005B LOCAL PANEL 25-5B Y Y U3 RB/ S/R3 593' 1-BDBB-281-0001B 250V RMOV Board 1B Y Y U1 RB/ Q/R1 593' 1-BDBB-281-0001C 250V RMOV Board 1C Y Y U1 RB/ Q/R1 565' 2-BDBB-281-0002B 250V RMOV Board 2B Y Y U2 RB/ Q/R14 593' 3-BDBB-281-0003B 250V RMOV Board 3B Y Y U3 RB/ SD BD F 593' 0-BDDD-280-0001 250V Battery Board 1 Y Y U1 RB/P/R4 593' 0-BATA-248-0001 250V Main Battery 1 Y Y U1 RB/P/R4 593'
0-CHGA-248-0001 Unit Battery Charger 1 Y Y U1 RB/P/R4 593' 0-BDDD-280-0002 250V Battery Board 2 Y Y U2 RB/P/R10 593' 0-BATA-248-0002 250V Main Battery 2 Y Y U2 RB/P/R9 593' 0-CHGA-248-0002A Unit Battery Charger 2A Y Y U2 RB/P/R9 593' 0-BDDD-280-0003 250V Battery Board 3 Y Y U3 RB/P/R18 593' 0-BATA-248-0003 250V Main Battery 3 Y Y U3 RB/P/R18 593' 0-CHGA-248-0003 Unit Battery Charger 3 Y Y U3 RB/P/R18 593' 1-BDBB-268-0001B 480 V RMOV Board 1B Y Y U1 RB/ R/R1 593' 2-BDBB-268-0002B 480 V RMOV Board 2B Y Y U2 RB/ R/R14 593' 3-BDBB-268-0003B 480 V RMOV Board 3B Y Y U3 RB/ SD BD F 593' 0-BDAA-211-0000B 4 kV Shutdown Board B Y Y U1 RB 593 0-BDAA-211-0000D 4 kV Shutdown Board D Y Y U2 RB 593 3-BDAA-211-0000EA 4 kV Shutdown Board 3EA Y Y U3 DG/ 4KVSD BD 593 3-BDAA-211-0000EC 4 kV Shutdown Board 3EC Y Y U3 DG/ 4KVSD BD 593 FLEX 480V DG Battery TBD N N CB 593 Charging Distribution Panel CS/DIV I INBOARD 1FCV7525 INJECTION VALVE Y Y U1 RB/ R4/P 593' CS/DIV I Inboard Injection 2FCV7525 valve Y Y U2 RB/ P/R10 593' CS/DIV I Inboard Injection 1FCV7525 valve Y Y U3 RB/ P/R18 593' RHR/LOOP II OUTBOARD 2-FCV-74-74 DRYWELL SPRAY VALVE Y Y U2 RB / R12/S 593' RHR/LOOP II INBOARD 2-FCV-74-75 DRYWELL SPRAY VALVE Y Y U2 RB / R12/S 593' RHR/LOOP II OUTBOARD 3-FCV-74-60 Y Y U3 RB/ R19/S 593' DRYWELL SPRAY VALVE RHR/LOOP II INBOARD 3-FCV-74-61 Y Y U3 RB/ R19/S 593' DRYWELL SPRAY VALVE