ML22091A194

From kanterella
Jump to navigation Jump to search
2022 BFN POV Inspection Information Request
ML22091A194
Person / Time
Site: Browns Ferry  
Issue date: 03/08/2022
From: Geoffrey Ottenberg
NRC/RGN-II/DRS/EB1
To: Garner J
Tennessee Valley Authority
References
Download: ML22091A194 (64)


Text

From:

Ottenberg, Geoffrey To:

Garner, Justin Keith Cc:

Ottenberg, Geoffrey

Subject:

Upcoming BFN DBAI (programs) inspection (IP71111.21N.02)

Date:

Tuesday, March 08, 2022 1:00:10 PM Attachments:

2022 BFN - POV Inspection Information Request.docx BFN POV Data-rev 1.docx

Justin,

Thanks for working with me so far to get the Design Basis Assurance (programs)

Inspection, also known as the Power Operated Valve inspection, started. As I mentioned previously, please treat the highlighted dates in the POV Inspection Information Request as tentative until we can firm up the dates for the information gathering visit.

Please see the attached request for some initial information that will help the team select our final inspection sample. Part of the request is contained in the attached access database, BFN POV Data-rev 1.docx, which asks for specific data points relevant to the indicated valves to be entered into the database and provided back to us. (PLEASE NOTE:

the Access database is sent as a Word document in order to be able to transmit it via e-mail. You will need to change the file extension of the BFN POV Data-rev 1.docx file from

.docx to.accdb to convert it back into an Access file.) Please provide as much of the requested information as possible, if it is readily available.

The following information will help when filling out the database with the requested valve-specific information:

You may have to enable content before using-this is only done once and shouldnt pop up again. It is understood that not all fields will be entered. Also please note that when entering data into the various fields there is a text box at the bottom left of the data entry form that details to the person entering the data what needs to be entered. For example, when on the Docket field the text at the bottom will state Enter the Docket number last 3 digits. Also, when entering text in the comment field and it is desired to start a new line, it is necessary to hit control+enter to start a new line.

Feel free to reach out to me with any questions you may have regarding anything related to the inspection (inspection procedure, information request, etc.) and Ill do my best to get any questions/concerns addressed. Im looking forward to the inspection.

Geoff Ottenberg Senior Reactor Inspector - Engineering Branch 1 Division of Reactor Safety U.S. Nuclear Regulatory Commission 404-997-4658 Geoffrey.Ottenberg@nrc.gov

Browns Ferry Nuclear Plant - Design Bases Assurance Inspection (Programs)

Initial Information Request Inspection Procedure:

71111.21N, Design Bases Assurance Inspection (Programs), 1N.02, Design-Basis Capability of Power-Operated Valves Under 10 CFR 50.55a Requirements, dated October 9, 2020 (ADAMS ML20220A667)

Inspection Dates:

Information Gathering Visit: June 13-17, 2022 Preparation Week: July 11-15, 2022 Onsite Week 1: July 18-22, 2022 Onsite Week 2: August 1-5, 2022 Inspection Report:

05000259, 260, 296/2022011 (Standalone Inspection Report)

Inspectors:

G. Ottenberg (Lead/Mechanical), TBD (Mechanical/Electrical), and R. Waters (Mechanical-contractor)

The purpose of this letter is to notify you that three inspectors from Region II will conduct an inspection at your site in accordance with Inspection Procedure 71111.21N, Design Bases Assurance Inspection (Programs), Attachment 21N.02, Design-Basis Capability of Power-Operated Valves Under 10 CFR 50.55a Requirements. This is not considered a team inspection. The inspection will evaluate the implementation of the programs regarding power operated valves (POVs) for compliance with 10 CFR 50.55a at the Browns Ferry Nuclear Plant.

The inspectors will select samples of components that are risk significant and within the scope of the program.

On June 13, 2022, Mr. Geoffrey Ottenberg, a Senior Reactor Inspector from the NRCs Region II office, will begin the inspection with an information gathering visit to the site, if pandemic conditions allow. The purpose of the visit is to become familiar with your program and procedures which are supposed to ensure your compliance with 10 CFR 50.55a for POVs. This will require meetings with members of your staff to discuss aspects of the program including any specific applicable regulatory commitments made by the site and your use of regulatory guides or industry standards. Your processes for generating field instructions for POV switch settings and test acceptance criteria from design documents is also expected to be discussed. Plant walkdowns to observe the potential inspection sample are expected to occur during the information gathering visit, if a site visit is made.

The enclosure lists documents that are needed prior to the information gathering visit. Please provide the referenced information to the Region II Office by June 6, 2022. Additional documents may be requested during the information gathering visit. The inspectors will try to minimize your administrative burden by specifically identifying only those documents required for inspection preparation. The additional information should be provided to the Inspectors in the Region II office by July 11, 2022. During the information gathering visit, Mr. Ottenberg will also discuss the following inspection support administrative details: (1) availability of knowledgeable plant engineering and licensing personnel to serve as points of contact during the inspection, (2) method of tracking inspector requests during the inspection, (3) computer access, (4) working space, (5) arrangements for site access, and (6) other applicable information.

INFORMATION REQUEST FOR BROWNS FERRY NUCLEAR PLANT DESIGN BASES ASSURANCE INSPECTION (PROGRAMS)

(10 CFR 50.55a POWER OPERATED VALVE PROGRAMS IMPLEMENTATION)

Prior to the information gathering visit, please provide the information electronically in.pdf files, Excel, or other searchable format on CDROM (or FTP site, SharePoint, etc.). The CDROM (or website) should be indexed and hyperlinked to facilitate ease of use.

Contact Information:

Geoffrey Ottenberg (404) 997-4658 Geoffrey.Ottenberg@nrc.gov Information Gathering Visit: An information gathering visit is currently scheduled the week of June 13-June 17, 2022. During this visit, we would like to identify the component samples for this inspection. Wed like to meet with valve specialists to discuss the upcoming inspection and our sample selection process. Purposes of the site visit are to: (a) discuss the scope of the planned inspection; (b) obtain advance information to review in preparation for the inspection; (c) ensure that the information to be reviewed is available at the beginning of the inspection; and (d) verify that logistical issues (such as obtaining both site and computer system access and arranging the location of the inspection team working area) will be resolved prior to inspector arrival. Assuming that a site visit will be completed, please reserve a room during the scheduled inspection dates. We request the room have a telephone, wireless internet access, and a licensee computer with access to procedures, corrective action program documents, and a printer.

Logistics:

Information gathering visit: June 13-June 17, 2022 Onsite inspection weeks: July 18-22 and August 1-5, 2022 Please schedule an entrance meeting for around 3:00 p.m. on Monday, July 18, 2022 (approximately 15 minutes). The date and time of the exit meeting will be discussed at a later date. In addition, Id like to have a daily debrief with your inspection support staff at a convenient time in the afternoons for both onsite inspection weeks (Time TBD, approximately 30 minutes).

We will need a conference room as workspace for the inspectors. We will also need an area available for conducting interviews. Please provide access to your document system (preferably at least one computer in our conference room), nearby printers, and Wi-Fi access.

During the information gathering visit, please provide info on (1) conference room location &

phone number, (2) cafeteria location/hours, and (3) engineering staff normal working hours.

Also, please let me know if there are any potential resource conflicts during our scheduled inspection weeks (Fridays off, EOP drills, management retreats) and well do our best to accommodate.

Team Members:

Geoffrey Ottenberg (Inspection Lead, Mechanical)

TBD (Mechanical/Electrical)

R. Waters (Mechanical-contractor)

Please verify the status of access authorization and remaining requirements for unescorted access for each inspector. Please provide me with a list of exceptions, and I will take action to address them.

Info Request:

1. A word-searchable Updated Final Safety Analysis Report (UFSAR), Technical Specifications (TS), and TS Bases. If each document is not available in a single file, please ensure a collective table of contents is provided.
2. Indicate if the NRC has granted a license amendment to categorize structures, systems, and components in accordance with 10 CFR 50.69, and if so, please provide the risk-informed safety category of the POVs important to safety at the site.
3. All NRC correspondence regarding the stations response to Generic Letter (GL) 89-10, GL 95-07, and GL 96-05, including any NRC requests for additional information (RAIs) and any NRC Safety Evaluation Report(s) associated with your sites MOV program. Include any NRC inspection reports that were conducted to close out your GL responses.
4. Any NRC correspondence regarding the stations commitments for the AOV program (if any). Please include any AOV-related regulatory commitments that are currently being tracked in the stations regulatory commitment management program.
5. Site (and corporate if applicable) procedures associated with implementation of the inservice testing (IST) program required by 10 CFR 50.55a
6. Site (and corporate if applicable) procedures associated with implementation of the MOV program required by 10 CFR 50.55a(b)(3)(ii) and/or ASME OM Code Mandatory Appendix III (as applicable).
7. Site (and corporate if applicable) procedures associated with implementation of the AOV program.
8. List of corrective action documents related to the MOV and AOV programs since January 1, 2017. Please provide list of corrective action program reports that are applicable to programmatic aspects only-no need to provide them for individual valves in the programs.
9. List of modifications, repairs, or replacement of safety related power operated valves (motor, air, solenoid, hydraulic, and pyrotechnic operated) completed since January 1, 2017, including date completed.
10. Any self-assessments or QA assessments of the MOV/AOV programs (performed since January 1, 2017).
11. List of systems (system numbers/designators and corresponding names).
12. List of site contacts that will be associated with the inspection
13. For the POVs listed in the accompanying database, please fill in as much of the indicated data as possible and provide the database back to the inspectors.

PAPERWORK REDUCTION ACT STATEMENT This letter contains voluntary information collections that are subject to the Paperwork Reduction Act of 1995 (44 U.S.C. 3501 et seq.). The Office of Management and Budget (OMB) approved these information collections (approval number 3150-0011). The burden to the public for these information collections is estimated to average 60 hours6.944444e-4 days <br />0.0167 hours <br />9.920635e-5 weeks <br />2.283e-5 months <br /> per response. Send comments regarding this information collection to the Information Services Branch, Office of the Chief Information Officer, Mail Stop: O-1F13, U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001, or by e-mail to Infocollects.Resource@nrc.gov, and to the Desk Officer, Office of Information and Regulatory Affairs, NEOB-10202, (3150-0011) Office of Management and Budget, Washington, DC 20503.

Public Protection Notification The NRC may not conduct nor sponsor, and a person is not required to respond to, a request for information or an information collection requirement unless the requesting document displays a currently valid OMB control number.

POV Data Entry Docket 259 PLANT Browns Ferry 1 Valve ID 1-FCV-1-135 Date POV Inspection 07/18/2022

System Description

Main Steam - RFPT 1B HP STOP VLV Size (inches) 4 Actuator Manufacturer Actuator Model Motor Size Design D/P Close Valve Information Actuator Information Valve Type Gate Valve Manufacturer Safety Function Close ASME Class Risk Motor Type Motor Manufacturer Control Switch Trip Close Control Switch Trip Open POV Type HOV ft-lbs Design Information Design D/P Open Required Thrust Close Required Torque Close Required Thrust Open Required Torque Open Design Flow Open Design Flow Close Valve Factor Assumed Close Valve Factor Assumed Open Min Air End Stroke (AOV)

Max Air Begin Stroke (AOV)

Stem COF Assumed LSB Assumed (percent)

Bearing COF Assumed (AOV)

Min Air Begin Stroke (AOV)

Max Spring Preload Begin Max Spring Preload End Max Air End Stroke (AOV)

Min Spring Preload Begin Min Spring Preload End Least Available Test Ambient Temp Close Test Information Test Motor Voltage Close Test D/P Close Test Pressure Close Test Flow Close Test System Temp Close Test System Temp Open Test Ambient Temp Open Test D/P Open Test Pressure Open Test Flow Open Test Motor Voltage Open

% Uncertainty Applied Valve Factor Measure Open Valve Factor Available Close Test Torque Close Test Thrust Open Test Torque Open Valve Factor Measured Close LSB Measured Bearing COF Measured Close Valve Factor Available Open Stem COF Measured Close Stem COF Measured Open Bearing COF Measured Open Test Thrust Close POV Qualifying Basis

% Margin Close

% Margin Open Design Basis Comments:

ft-lbs ft-lbs lbs lbs psig gpm psig gpm psig psig psig psig psig psig psig psig psig psig gpm OF OF psig psig gpm OF OF ft-lbs ft-lbs lbs lbs lbs

Docket 259 PLANT Browns Ferry 1 Valve ID 1-FCV-1-14 Date POV Inspection 07/18/2022

System Description

Main Steam - MS LN A INBD ISOL Size (inches) 26 Actuator Manufacturer Actuator Model Motor Size Design D/P Close Valve Information Actuator Information Valve Type Globe Valve Manufacturer Safety Function Close ASME Class Risk Motor Type Motor Manufacturer Control Switch Trip Close Control Switch Trip Open POV Type AOV ft-lbs Design Information Design D/P Open Required Thrust Close Required Torque Close Required Thrust Open Required Torque Open Design Flow Open Design Flow Close Valve Factor Assumed Close Valve Factor Assumed Open Min Air End Stroke (AOV)

Max Air Begin Stroke (AOV)

Stem COF Assumed LSB Assumed (percent)

Bearing COF Assumed (AOV)

Min Air Begin Stroke (AOV)

Max Spring Preload Begin Max Spring Preload End Max Air End Stroke (AOV)

Min Spring Preload Begin Min Spring Preload End Least Available Test Ambient Temp Close Test Information Test Motor Voltage Close Test D/P Close Test Pressure Close Test Flow Close Test System Temp Close Test System Temp Open Test Ambient Temp Open Test D/P Open Test Pressure Open Test Flow Open Test Motor Voltage Open

% Uncertainty Applied Valve Factor Measure Open Valve Factor Available Close Test Torque Close Test Thrust Open Test Torque Open Valve Factor Measured Close LSB Measured Bearing COF Measured Close Valve Factor Available Open Stem COF Measured Close Stem COF Measured Open Bearing COF Measured Open Test Thrust Close POV Qualifying Basis

% Margin Close

% Margin Open Design Basis Comments:

ft-lbs ft-lbs lbs lbs psig gpm psig gpm psig psig psig psig psig psig psig psig psig psig gpm OF OF psig psig gpm OF OF ft-lbs ft-lbs lbs lbs lbs

Docket 259 PLANT Browns Ferry 1 Valve ID 1-FCV-23-46 Date POV Inspection 07/18/2022

System Description

Residual Heat Removal Service Water System -

RHR HTX B OUTLT Size (inches) 16 Actuator Manufacturer Actuator Model Motor Size Design D/P Close Valve Information Actuator Information Valve Type Globe Valve Manufacturer Safety Function Open/Close ASME Class Risk Motor Type Motor Manufacturer Control Switch Trip Close Control Switch Trip Open POV Type MOV ft-lbs Design Information Design D/P Open Required Thrust Close Required Torque Close Required Thrust Open Required Torque Open Design Flow Open Design Flow Close Valve Factor Assumed Close Valve Factor Assumed Open Min Air End Stroke (AOV)

Max Air Begin Stroke (AOV)

Stem COF Assumed LSB Assumed (percent)

Bearing COF Assumed (AOV)

Min Air Begin Stroke (AOV)

Max Spring Preload Begin Max Spring Preload End Max Air End Stroke (AOV)

Min Spring Preload Begin Min Spring Preload End Least Available Test Ambient Temp Close Test Information Test Motor Voltage Close Test D/P Close Test Pressure Close Test Flow Close Test System Temp Close Test System Temp Open Test Ambient Temp Open Test D/P Open Test Pressure Open Test Flow Open Test Motor Voltage Open

% Uncertainty Applied Valve Factor Measure Open Valve Factor Available Close Test Torque Close Test Thrust Open Test Torque Open Valve Factor Measured Close LSB Measured Bearing COF Measured Close Valve Factor Available Open Stem COF Measured Close Stem COF Measured Open Bearing COF Measured Open Test Thrust Close POV Qualifying Basis

% Margin Close

% Margin Open Design Basis Comments:

ft-lbs ft-lbs lbs lbs psig gpm psig gpm psig psig psig psig psig psig psig psig psig psig gpm OF OF psig psig gpm OF OF ft-lbs ft-lbs lbs lbs lbs

Docket 259 PLANT Browns Ferry 1 Valve ID 1-FCV-71-2 Date POV Inspection 07/18/2022

System Description

Reactor Core Isolation Cooling System - RCIC STM LN INBD CNTMT ISOL Size (inches) 3 Actuator Manufacturer Actuator Model Motor Size Design D/P Close Valve Information Actuator Information Valve Type Gate Valve Manufacturer Safety Function Open/Close ASME Class Risk Motor Type Motor Manufacturer Control Switch Trip Close Control Switch Trip Open POV Type MOV ft-lbs Design Information Design D/P Open Required Thrust Close Required Torque Close Required Thrust Open Required Torque Open Design Flow Open Design Flow Close Valve Factor Assumed Close Valve Factor Assumed Open Min Air End Stroke (AOV)

Max Air Begin Stroke (AOV)

Stem COF Assumed LSB Assumed (percent)

Bearing COF Assumed (AOV)

Min Air Begin Stroke (AOV)

Max Spring Preload Begin Max Spring Preload End Max Air End Stroke (AOV)

Min Spring Preload Begin Min Spring Preload End Least Available Test Ambient Temp Close Test Information Test Motor Voltage Close Test D/P Close Test Pressure Close Test Flow Close Test System Temp Close Test System Temp Open Test Ambient Temp Open Test D/P Open Test Pressure Open Test Flow Open Test Motor Voltage Open

% Uncertainty Applied Valve Factor Measure Open Valve Factor Available Close Test Torque Close Test Thrust Open Test Torque Open Valve Factor Measured Close LSB Measured Bearing COF Measured Close Valve Factor Available Open Stem COF Measured Close Stem COF Measured Open Bearing COF Measured Open Test Thrust Close POV Qualifying Basis

% Margin Close

% Margin Open Design Basis Comments:

ft-lbs ft-lbs lbs lbs psig gpm psig gpm psig psig psig psig psig psig psig psig psig psig gpm OF OF psig psig gpm OF OF ft-lbs ft-lbs lbs lbs lbs

Docket 259 PLANT Browns Ferry 1 Valve ID 1-FCV-73-2 Date POV Inspection 07/18/2022

System Description

High Pressure Coolant Injection - HPCI STM LN INBD ISOL Size (inches) 10 Actuator Manufacturer Actuator Model Motor Size Design D/P Close Valve Information Actuator Information Valve Type Gate Valve Manufacturer Safety Function Open/Close ASME Class Risk Motor Type Motor Manufacturer Control Switch Trip Close Control Switch Trip Open POV Type MOV ft-lbs Design Information Design D/P Open Required Thrust Close Required Torque Close Required Thrust Open Required Torque Open Design Flow Open Design Flow Close Valve Factor Assumed Close Valve Factor Assumed Open Min Air End Stroke (AOV)

Max Air Begin Stroke (AOV)

Stem COF Assumed LSB Assumed (percent)

Bearing COF Assumed (AOV)

Min Air Begin Stroke (AOV)

Max Spring Preload Begin Max Spring Preload End Max Air End Stroke (AOV)

Min Spring Preload Begin Min Spring Preload End Least Available Test Ambient Temp Close Test Information Test Motor Voltage Close Test D/P Close Test Pressure Close Test Flow Close Test System Temp Close Test System Temp Open Test Ambient Temp Open Test D/P Open Test Pressure Open Test Flow Open Test Motor Voltage Open

% Uncertainty Applied Valve Factor Measure Open Valve Factor Available Close Test Torque Close Test Thrust Open Test Torque Open Valve Factor Measured Close LSB Measured Bearing COF Measured Close Valve Factor Available Open Stem COF Measured Close Stem COF Measured Open Bearing COF Measured Open Test Thrust Close POV Qualifying Basis

% Margin Close

% Margin Open Design Basis Comments:

ft-lbs ft-lbs lbs lbs psig gpm psig gpm psig psig psig psig psig psig psig psig psig psig gpm OF OF psig psig gpm OF OF ft-lbs ft-lbs lbs lbs lbs

Docket 259 PLANT Browns Ferry 1 Valve ID 1-FCV-73-26 Date POV Inspection 07/18/2022

System Description

High Pressure Coolant Injection - PSC TO HPCI INBD ISOL Size (inches) 16 Actuator Manufacturer Actuator Model Motor Size Design D/P Close Valve Information Actuator Information Valve Type Gate Valve Manufacturer Safety Function Open/Close ASME Class Risk Motor Type Motor Manufacturer Control Switch Trip Close Control Switch Trip Open POV Type MOV ft-lbs Design Information Design D/P Open Required Thrust Close Required Torque Close Required Thrust Open Required Torque Open Design Flow Open Design Flow Close Valve Factor Assumed Close Valve Factor Assumed Open Min Air End Stroke (AOV)

Max Air Begin Stroke (AOV)

Stem COF Assumed LSB Assumed (percent)

Bearing COF Assumed (AOV)

Min Air Begin Stroke (AOV)

Max Spring Preload Begin Max Spring Preload End Max Air End Stroke (AOV)

Min Spring Preload Begin Min Spring Preload End Least Available Test Ambient Temp Close Test Information Test Motor Voltage Close Test D/P Close Test Pressure Close Test Flow Close Test System Temp Close Test System Temp Open Test Ambient Temp Open Test D/P Open Test Pressure Open Test Flow Open Test Motor Voltage Open

% Uncertainty Applied Valve Factor Measure Open Valve Factor Available Close Test Torque Close Test Thrust Open Test Torque Open Valve Factor Measured Close LSB Measured Bearing COF Measured Close Valve Factor Available Open Stem COF Measured Close Stem COF Measured Open Bearing COF Measured Open Test Thrust Close POV Qualifying Basis

% Margin Close

% Margin Open Design Basis Comments:

ft-lbs ft-lbs lbs lbs psig gpm psig gpm psig psig psig psig psig psig psig psig psig psig gpm OF OF psig psig gpm OF OF ft-lbs ft-lbs lbs lbs lbs

Docket 259 PLANT Browns Ferry 1 Valve ID 1-FCV-74-52 Date POV Inspection 07/18/2022

System Description

Residual Heat Removal System - RHR LPI THROTTLE Size (inches) 24 Actuator Manufacturer Actuator Model Motor Size Design D/P Close Valve Information Actuator Information Valve Type Globe Valve Manufacturer Safety Function Open/Close ASME Class Risk Motor Type Motor Manufacturer Control Switch Trip Close Control Switch Trip Open POV Type MOV ft-lbs Design Information Design D/P Open Required Thrust Close Required Torque Close Required Thrust Open Required Torque Open Design Flow Open Design Flow Close Valve Factor Assumed Close Valve Factor Assumed Open Min Air End Stroke (AOV)

Max Air Begin Stroke (AOV)

Stem COF Assumed LSB Assumed (percent)

Bearing COF Assumed (AOV)

Min Air Begin Stroke (AOV)

Max Spring Preload Begin Max Spring Preload End Max Air End Stroke (AOV)

Min Spring Preload Begin Min Spring Preload End Least Available Test Ambient Temp Close Test Information Test Motor Voltage Close Test D/P Close Test Pressure Close Test Flow Close Test System Temp Close Test System Temp Open Test Ambient Temp Open Test D/P Open Test Pressure Open Test Flow Open Test Motor Voltage Open

% Uncertainty Applied Valve Factor Measure Open Valve Factor Available Close Test Torque Close Test Thrust Open Test Torque Open Valve Factor Measured Close LSB Measured Bearing COF Measured Close Valve Factor Available Open Stem COF Measured Close Stem COF Measured Open Bearing COF Measured Open Test Thrust Close POV Qualifying Basis

% Margin Close

% Margin Open Design Basis Comments:

ft-lbs ft-lbs lbs lbs psig gpm psig gpm psig psig psig psig psig psig psig psig psig psig gpm OF OF psig psig gpm OF OF ft-lbs ft-lbs lbs lbs lbs

Docket 259 PLANT Browns Ferry 1 Valve ID 1-FCV-75-25 Date POV Inspection 07/18/2022

System Description

Core Spray Cooling System - CS LPI INJ Size (inches) 12 Actuator Manufacturer Actuator Model Motor Size Design D/P Close Valve Information Actuator Information Valve Type Gate Valve Manufacturer Safety Function Open/Close ASME Class Risk Motor Type Motor Manufacturer Control Switch Trip Close Control Switch Trip Open POV Type MOV ft-lbs Design Information Design D/P Open Required Thrust Close Required Torque Close Required Thrust Open Required Torque Open Design Flow Open Design Flow Close Valve Factor Assumed Close Valve Factor Assumed Open Min Air End Stroke (AOV)

Max Air Begin Stroke (AOV)

Stem COF Assumed LSB Assumed (percent)

Bearing COF Assumed (AOV)

Min Air Begin Stroke (AOV)

Max Spring Preload Begin Max Spring Preload End Max Air End Stroke (AOV)

Min Spring Preload Begin Min Spring Preload End Least Available Test Ambient Temp Close Test Information Test Motor Voltage Close Test D/P Close Test Pressure Close Test Flow Close Test System Temp Close Test System Temp Open Test Ambient Temp Open Test D/P Open Test Pressure Open Test Flow Open Test Motor Voltage Open

% Uncertainty Applied Valve Factor Measure Open Valve Factor Available Close Test Torque Close Test Thrust Open Test Torque Open Valve Factor Measured Close LSB Measured Bearing COF Measured Close Valve Factor Available Open Stem COF Measured Close Stem COF Measured Open Bearing COF Measured Open Test Thrust Close POV Qualifying Basis

% Margin Close

% Margin Open Design Basis Comments:

ft-lbs ft-lbs lbs lbs psig gpm psig gpm psig psig psig psig psig psig psig psig psig psig gpm OF OF psig psig gpm OF OF ft-lbs ft-lbs lbs lbs lbs

Docket 259 PLANT Browns Ferry 1 Valve ID 1-FCV-77-15B Date POV Inspection 07/18/2022

System Description

Radwaste System - DW EQ DRN SUMP OUTBD ISOL Size (inches) 3 Actuator Manufacturer Actuator Model Motor Size Design D/P Close Valve Information Actuator Information Valve Type Ball Valve Manufacturer Safety Function Close ASME Class Risk Motor Type Motor Manufacturer Control Switch Trip Close Control Switch Trip Open POV Type AOV ft-lbs Design Information Design D/P Open Required Thrust Close Required Torque Close Required Thrust Open Required Torque Open Design Flow Open Design Flow Close Valve Factor Assumed Close Valve Factor Assumed Open Min Air End Stroke (AOV)

Max Air Begin Stroke (AOV)

Stem COF Assumed LSB Assumed (percent)

Bearing COF Assumed (AOV)

Min Air Begin Stroke (AOV)

Max Spring Preload Begin Max Spring Preload End Max Air End Stroke (AOV)

Min Spring Preload Begin Min Spring Preload End Least Available Test Ambient Temp Close Test Information Test Motor Voltage Close Test D/P Close Test Pressure Close Test Flow Close Test System Temp Close Test System Temp Open Test Ambient Temp Open Test D/P Open Test Pressure Open Test Flow Open Test Motor Voltage Open

% Uncertainty Applied Valve Factor Measure Open Valve Factor Available Close Test Torque Close Test Thrust Open Test Torque Open Valve Factor Measured Close LSB Measured Bearing COF Measured Close Valve Factor Available Open Stem COF Measured Close Stem COF Measured Open Bearing COF Measured Open Test Thrust Close POV Qualifying Basis

% Margin Close

% Margin Open Design Basis Comments:

ft-lbs ft-lbs lbs lbs psig gpm psig gpm psig psig psig psig psig psig psig psig psig psig gpm OF OF psig psig gpm OF OF ft-lbs ft-lbs lbs lbs lbs

Docket 259 PLANT Browns Ferry 1 Valve ID 1-FCV-85-37E Date POV Inspection 07/18/2022

System Description

Control Rod Drive System - SDIV DRN ISOL EAST Size (inches) 2 Actuator Manufacturer Actuator Model Motor Size Design D/P Close Valve Information Actuator Information Valve Type Globe Valve Manufacturer Safety Function Close ASME Class Risk Motor Type Motor Manufacturer Control Switch Trip Close Control Switch Trip Open POV Type AOV ft-lbs Design Information Design D/P Open Required Thrust Close Required Torque Close Required Thrust Open Required Torque Open Design Flow Open Design Flow Close Valve Factor Assumed Close Valve Factor Assumed Open Min Air End Stroke (AOV)

Max Air Begin Stroke (AOV)

Stem COF Assumed LSB Assumed (percent)

Bearing COF Assumed (AOV)

Min Air Begin Stroke (AOV)

Max Spring Preload Begin Max Spring Preload End Max Air End Stroke (AOV)

Min Spring Preload Begin Min Spring Preload End Least Available Test Ambient Temp Close Test Information Test Motor Voltage Close Test D/P Close Test Pressure Close Test Flow Close Test System Temp Close Test System Temp Open Test Ambient Temp Open Test D/P Open Test Pressure Open Test Flow Open Test Motor Voltage Open

% Uncertainty Applied Valve Factor Measure Open Valve Factor Available Close Test Torque Close Test Thrust Open Test Torque Open Valve Factor Measured Close LSB Measured Bearing COF Measured Close Valve Factor Available Open Stem COF Measured Close Stem COF Measured Open Bearing COF Measured Open Test Thrust Close POV Qualifying Basis

% Margin Close

% Margin Open Design Basis Comments:

ft-lbs ft-lbs lbs lbs psig gpm psig gpm psig psig psig psig psig psig psig psig psig psig gpm OF OF psig psig gpm OF OF ft-lbs ft-lbs lbs lbs lbs

Docket 260 PLANT Browns Ferry 2 Valve ID 2-FCV-1-143 Date POV Inspection 07/18/2022

System Description

Main Steam - RFPT 2C HP STOP VLV Size (inches) 4 Actuator Manufacturer Actuator Model Motor Size Design D/P Close Valve Information Actuator Information Valve Type Gate Valve Manufacturer Safety Function Close ASME Class Risk Motor Type Motor Manufacturer Control Switch Trip Close Control Switch Trip Open POV Type HOV ft-lbs Design Information Design D/P Open Required Thrust Close Required Torque Close Required Thrust Open Required Torque Open Design Flow Open Design Flow Close Valve Factor Assumed Close Valve Factor Assumed Open Min Air End Stroke (AOV)

Max Air Begin Stroke (AOV)

Stem COF Assumed LSB Assumed (percent)

Bearing COF Assumed (AOV)

Min Air Begin Stroke (AOV)

Max Spring Preload Begin Max Spring Preload End Max Air End Stroke (AOV)

Min Spring Preload Begin Min Spring Preload End Least Available Test Ambient Temp Close Test Information Test Motor Voltage Close Test D/P Close Test Pressure Close Test Flow Close Test System Temp Close Test System Temp Open Test Ambient Temp Open Test D/P Open Test Pressure Open Test Flow Open Test Motor Voltage Open

% Uncertainty Applied Valve Factor Measure Open Valve Factor Available Close Test Torque Close Test Thrust Open Test Torque Open Valve Factor Measured Close LSB Measured Bearing COF Measured Close Valve Factor Available Open Stem COF Measured Close Stem COF Measured Open Bearing COF Measured Open Test Thrust Close POV Qualifying Basis

% Margin Close

% Margin Open Design Basis Comments:

ft-lbs ft-lbs lbs lbs psig gpm psig gpm psig psig psig psig psig psig psig psig psig psig gpm OF OF psig psig gpm OF OF ft-lbs ft-lbs lbs lbs lbs

Docket 260 PLANT Browns Ferry 2 Valve ID 2-FCV-1-37 Date POV Inspection 07/18/2022

System Description

Main Steam - MS LN C INBD ISOL Size (inches) 26 Actuator Manufacturer Actuator Model Motor Size Design D/P Close Valve Information Actuator Information Valve Type Globe Valve Manufacturer Safety Function Close ASME Class Risk Motor Type Motor Manufacturer Control Switch Trip Close Control Switch Trip Open POV Type AOV ft-lbs Design Information Design D/P Open Required Thrust Close Required Torque Close Required Thrust Open Required Torque Open Design Flow Open Design Flow Close Valve Factor Assumed Close Valve Factor Assumed Open Min Air End Stroke (AOV)

Max Air Begin Stroke (AOV)

Stem COF Assumed LSB Assumed (percent)

Bearing COF Assumed (AOV)

Min Air Begin Stroke (AOV)

Max Spring Preload Begin Max Spring Preload End Max Air End Stroke (AOV)

Min Spring Preload Begin Min Spring Preload End Least Available Test Ambient Temp Close Test Information Test Motor Voltage Close Test D/P Close Test Pressure Close Test Flow Close Test System Temp Close Test System Temp Open Test Ambient Temp Open Test D/P Open Test Pressure Open Test Flow Open Test Motor Voltage Open

% Uncertainty Applied Valve Factor Measure Open Valve Factor Available Close Test Torque Close Test Thrust Open Test Torque Open Valve Factor Measured Close LSB Measured Bearing COF Measured Close Valve Factor Available Open Stem COF Measured Close Stem COF Measured Open Bearing COF Measured Open Test Thrust Close POV Qualifying Basis

% Margin Close

% Margin Open Design Basis Comments:

ft-lbs ft-lbs lbs lbs psig gpm psig gpm psig psig psig psig psig psig psig psig psig psig gpm OF OF psig psig gpm OF OF ft-lbs ft-lbs lbs lbs lbs

Docket 260 PLANT Browns Ferry 2 Valve ID 2-FCV-23-34 Date POV Inspection 07/18/2022

System Description

Residual Heat Removal Service Water System -

RHR HTX A OUTLT Size (inches) 16 Actuator Manufacturer Actuator Model Motor Size Design D/P Close Valve Information Actuator Information Valve Type Globe Valve Manufacturer Safety Function Open/Close ASME Class Risk Motor Type Motor Manufacturer Control Switch Trip Close Control Switch Trip Open POV Type MOV ft-lbs Design Information Design D/P Open Required Thrust Close Required Torque Close Required Thrust Open Required Torque Open Design Flow Open Design Flow Close Valve Factor Assumed Close Valve Factor Assumed Open Min Air End Stroke (AOV)

Max Air Begin Stroke (AOV)

Stem COF Assumed LSB Assumed (percent)

Bearing COF Assumed (AOV)

Min Air Begin Stroke (AOV)

Max Spring Preload Begin Max Spring Preload End Max Air End Stroke (AOV)

Min Spring Preload Begin Min Spring Preload End Least Available Test Ambient Temp Close Test Information Test Motor Voltage Close Test D/P Close Test Pressure Close Test Flow Close Test System Temp Close Test System Temp Open Test Ambient Temp Open Test D/P Open Test Pressure Open Test Flow Open Test Motor Voltage Open

% Uncertainty Applied Valve Factor Measure Open Valve Factor Available Close Test Torque Close Test Thrust Open Test Torque Open Valve Factor Measured Close LSB Measured Bearing COF Measured Close Valve Factor Available Open Stem COF Measured Close Stem COF Measured Open Bearing COF Measured Open Test Thrust Close POV Qualifying Basis

% Margin Close

% Margin Open Design Basis Comments:

ft-lbs ft-lbs lbs lbs psig gpm psig gpm psig psig psig psig psig psig psig psig psig psig gpm OF OF psig psig gpm OF OF ft-lbs ft-lbs lbs lbs lbs

Docket 260 PLANT Browns Ferry 2 Valve ID 2-FCV-23-52 Date POV Inspection 07/18/2022

System Description

Residual Heat Removal Service Water System -

RHRHTX D OUTLT Size (inches) 16 Actuator Manufacturer Actuator Model Motor Size Design D/P Close Valve Information Actuator Information Valve Type Globe Valve Manufacturer Safety Function Open/Close ASME Class Risk Motor Type Motor Manufacturer Control Switch Trip Close Control Switch Trip Open POV Type MOV ft-lbs Design Information Design D/P Open Required Thrust Close Required Torque Close Required Thrust Open Required Torque Open Design Flow Open Design Flow Close Valve Factor Assumed Close Valve Factor Assumed Open Min Air End Stroke (AOV)

Max Air Begin Stroke (AOV)

Stem COF Assumed LSB Assumed (percent)

Bearing COF Assumed (AOV)

Min Air Begin Stroke (AOV)

Max Spring Preload Begin Max Spring Preload End Max Air End Stroke (AOV)

Min Spring Preload Begin Min Spring Preload End Least Available Test Ambient Temp Close Test Information Test Motor Voltage Close Test D/P Close Test Pressure Close Test Flow Close Test System Temp Close Test System Temp Open Test Ambient Temp Open Test D/P Open Test Pressure Open Test Flow Open Test Motor Voltage Open

% Uncertainty Applied Valve Factor Measure Open Valve Factor Available Close Test Torque Close Test Thrust Open Test Torque Open Valve Factor Measured Close LSB Measured Bearing COF Measured Close Valve Factor Available Open Stem COF Measured Close Stem COF Measured Open Bearing COF Measured Open Test Thrust Close POV Qualifying Basis

% Margin Close

% Margin Open Design Basis Comments:

ft-lbs ft-lbs lbs lbs psig gpm psig gpm psig psig psig psig psig psig psig psig psig psig gpm OF OF psig psig gpm OF OF ft-lbs ft-lbs lbs lbs lbs

Docket 260 PLANT Browns Ferry 2 Valve ID 2-FCV-67-50 Date POV Inspection 07/18/2022

System Description

Emergency Equipment Cooling Water System -

EECW N HDR TO RBCCW HTX Size (inches) 8 Actuator Manufacturer Actuator Model Motor Size Design D/P Close Valve Information Actuator Information Valve Type Butterfly Valve Manufacturer Safety Function Close ASME Class Risk Motor Type Motor Manufacturer Control Switch Trip Close Control Switch Trip Open POV Type AOV ft-lbs Design Information Design D/P Open Required Thrust Close Required Torque Close Required Thrust Open Required Torque Open Design Flow Open Design Flow Close Valve Factor Assumed Close Valve Factor Assumed Open Min Air End Stroke (AOV)

Max Air Begin Stroke (AOV)

Stem COF Assumed LSB Assumed (percent)

Bearing COF Assumed (AOV)

Min Air Begin Stroke (AOV)

Max Spring Preload Begin Max Spring Preload End Max Air End Stroke (AOV)

Min Spring Preload Begin Min Spring Preload End Least Available Test Ambient Temp Close Test Information Test Motor Voltage Close Test D/P Close Test Pressure Close Test Flow Close Test System Temp Close Test System Temp Open Test Ambient Temp Open Test D/P Open Test Pressure Open Test Flow Open Test Motor Voltage Open

% Uncertainty Applied Valve Factor Measure Open Valve Factor Available Close Test Torque Close Test Thrust Open Test Torque Open Valve Factor Measured Close LSB Measured Bearing COF Measured Close Valve Factor Available Open Stem COF Measured Close Stem COF Measured Open Bearing COF Measured Open Test Thrust Close POV Qualifying Basis

% Margin Close

% Margin Open Design Basis Comments:

ft-lbs ft-lbs lbs lbs psig gpm psig gpm psig psig psig psig psig psig psig psig psig psig gpm OF OF psig psig gpm OF OF ft-lbs ft-lbs lbs lbs lbs

Docket 260 PLANT Browns Ferry 2 Valve ID 2-FCV-71-2 Date POV Inspection 07/18/2022

System Description

Reactor Core Isolation Cooling System - RCIC STM LN INBD CNTMT ISOL Size (inches) 3 Actuator Manufacturer Actuator Model Motor Size Design D/P Close Valve Information Actuator Information Valve Type Gate Valve Manufacturer Safety Function Open/Close ASME Class Risk Motor Type Motor Manufacturer Control Switch Trip Close Control Switch Trip Open POV Type MOV ft-lbs Design Information Design D/P Open Required Thrust Close Required Torque Close Required Thrust Open Required Torque Open Design Flow Open Design Flow Close Valve Factor Assumed Close Valve Factor Assumed Open Min Air End Stroke (AOV)

Max Air Begin Stroke (AOV)

Stem COF Assumed LSB Assumed (percent)

Bearing COF Assumed (AOV)

Min Air Begin Stroke (AOV)

Max Spring Preload Begin Max Spring Preload End Max Air End Stroke (AOV)

Min Spring Preload Begin Min Spring Preload End Least Available Test Ambient Temp Close Test Information Test Motor Voltage Close Test D/P Close Test Pressure Close Test Flow Close Test System Temp Close Test System Temp Open Test Ambient Temp Open Test D/P Open Test Pressure Open Test Flow Open Test Motor Voltage Open

% Uncertainty Applied Valve Factor Measure Open Valve Factor Available Close Test Torque Close Test Thrust Open Test Torque Open Valve Factor Measured Close LSB Measured Bearing COF Measured Close Valve Factor Available Open Stem COF Measured Close Stem COF Measured Open Bearing COF Measured Open Test Thrust Close POV Qualifying Basis

% Margin Close

% Margin Open Design Basis Comments:

ft-lbs ft-lbs lbs lbs psig gpm psig gpm psig psig psig psig psig psig psig psig psig psig gpm OF OF psig psig gpm OF OF ft-lbs ft-lbs lbs lbs lbs

Docket 260 PLANT Browns Ferry 2 Valve ID 2-FCV-73-16 Date POV Inspection 07/18/2022

System Description

High Pressure Coolant Injection System - HPCI TRB STM SPLY VLV Size (inches) 10 Actuator Manufacturer Actuator Model Motor Size Design D/P Close Valve Information Actuator Information Valve Type Gate Valve Manufacturer Safety Function Open ASME Class Risk Motor Type Motor Manufacturer Control Switch Trip Close Control Switch Trip Open POV Type MOV ft-lbs Design Information Design D/P Open Required Thrust Close Required Torque Close Required Thrust Open Required Torque Open Design Flow Open Design Flow Close Valve Factor Assumed Close Valve Factor Assumed Open Min Air End Stroke (AOV)

Max Air Begin Stroke (AOV)

Stem COF Assumed LSB Assumed (percent)

Bearing COF Assumed (AOV)

Min Air Begin Stroke (AOV)

Max Spring Preload Begin Max Spring Preload End Max Air End Stroke (AOV)

Min Spring Preload Begin Min Spring Preload End Least Available Test Ambient Temp Close Test Information Test Motor Voltage Close Test D/P Close Test Pressure Close Test Flow Close Test System Temp Close Test System Temp Open Test Ambient Temp Open Test D/P Open Test Pressure Open Test Flow Open Test Motor Voltage Open

% Uncertainty Applied Valve Factor Measure Open Valve Factor Available Close Test Torque Close Test Thrust Open Test Torque Open Valve Factor Measured Close LSB Measured Bearing COF Measured Close Valve Factor Available Open Stem COF Measured Close Stem COF Measured Open Bearing COF Measured Open Test Thrust Close POV Qualifying Basis

% Margin Close

% Margin Open Design Basis Comments:

ft-lbs ft-lbs lbs lbs psig gpm psig gpm psig psig psig psig psig psig psig psig psig psig gpm OF OF psig psig gpm OF OF ft-lbs ft-lbs lbs lbs lbs

Docket 260 PLANT Browns Ferry 2 Valve ID 2-FCV-74-57 Date POV Inspection 07/18/2022

System Description

Residual Heat Removal System - RHR LP I PSC RTN Size (inches) 18 Actuator Manufacturer Actuator Model Motor Size Design D/P Close Valve Information Actuator Information Valve Type Gate Valve Manufacturer Safety Function Open/Close ASME Class Risk Motor Type Motor Manufacturer Control Switch Trip Close Control Switch Trip Open POV Type MOV ft-lbs Design Information Design D/P Open Required Thrust Close Required Torque Close Required Thrust Open Required Torque Open Design Flow Open Design Flow Close Valve Factor Assumed Close Valve Factor Assumed Open Min Air End Stroke (AOV)

Max Air Begin Stroke (AOV)

Stem COF Assumed LSB Assumed (percent)

Bearing COF Assumed (AOV)

Min Air Begin Stroke (AOV)

Max Spring Preload Begin Max Spring Preload End Max Air End Stroke (AOV)

Min Spring Preload Begin Min Spring Preload End Least Available Test Ambient Temp Close Test Information Test Motor Voltage Close Test D/P Close Test Pressure Close Test Flow Close Test System Temp Close Test System Temp Open Test Ambient Temp Open Test D/P Open Test Pressure Open Test Flow Open Test Motor Voltage Open

% Uncertainty Applied Valve Factor Measure Open Valve Factor Available Close Test Torque Close Test Thrust Open Test Torque Open Valve Factor Measured Close LSB Measured Bearing COF Measured Close Valve Factor Available Open Stem COF Measured Close Stem COF Measured Open Bearing COF Measured Open Test Thrust Close POV Qualifying Basis

% Margin Close

% Margin Open Design Basis Comments:

ft-lbs ft-lbs lbs lbs psig gpm psig gpm psig psig psig psig psig psig psig psig psig psig gpm OF OF psig psig gpm OF OF ft-lbs ft-lbs lbs lbs lbs

Docket 260 PLANT Browns Ferry 2 Valve ID 2-FCV-74-67 Date POV Inspection 07/18/2022

System Description

Residual Heat Removal System - RHR LP II INJ Size (inches) 24 Actuator Manufacturer Actuator Model Motor Size Design D/P Close Valve Information Actuator Information Valve Type Gate Valve Manufacturer Safety Function Open/Close ASME Class Risk Motor Type Motor Manufacturer Control Switch Trip Close Control Switch Trip Open POV Type MOV ft-lbs Design Information Design D/P Open Required Thrust Close Required Torque Close Required Thrust Open Required Torque Open Design Flow Open Design Flow Close Valve Factor Assumed Close Valve Factor Assumed Open Min Air End Stroke (AOV)

Max Air Begin Stroke (AOV)

Stem COF Assumed LSB Assumed (percent)

Bearing COF Assumed (AOV)

Min Air Begin Stroke (AOV)

Max Spring Preload Begin Max Spring Preload End Max Air End Stroke (AOV)

Min Spring Preload Begin Min Spring Preload End Least Available Test Ambient Temp Close Test Information Test Motor Voltage Close Test D/P Close Test Pressure Close Test Flow Close Test System Temp Close Test System Temp Open Test Ambient Temp Open Test D/P Open Test Pressure Open Test Flow Open Test Motor Voltage Open

% Uncertainty Applied Valve Factor Measure Open Valve Factor Available Close Test Torque Close Test Thrust Open Test Torque Open Valve Factor Measured Close LSB Measured Bearing COF Measured Close Valve Factor Available Open Stem COF Measured Close Stem COF Measured Open Bearing COF Measured Open Test Thrust Close POV Qualifying Basis

% Margin Close

% Margin Open Design Basis Comments:

ft-lbs ft-lbs lbs lbs psig gpm psig gpm psig psig psig psig psig psig psig psig psig psig gpm OF OF psig psig gpm OF OF ft-lbs ft-lbs lbs lbs lbs

Docket 260 PLANT Browns Ferry 2 Valve ID 2-FCV-77-2B Date POV Inspection 07/18/2022

System Description

Radwaste System - DW FL DRN SMP OUTBD ISOL Size (inches) 3 Actuator Manufacturer Actuator Model Motor Size Design D/P Close Valve Information Actuator Information Valve Type Ball Valve Manufacturer Safety Function Close ASME Class Risk Motor Type Motor Manufacturer Control Switch Trip Close Control Switch Trip Open POV Type AOV ft-lbs Design Information Design D/P Open Required Thrust Close Required Torque Close Required Thrust Open Required Torque Open Design Flow Open Design Flow Close Valve Factor Assumed Close Valve Factor Assumed Open Min Air End Stroke (AOV)

Max Air Begin Stroke (AOV)

Stem COF Assumed LSB Assumed (percent)

Bearing COF Assumed (AOV)

Min Air Begin Stroke (AOV)

Max Spring Preload Begin Max Spring Preload End Max Air End Stroke (AOV)

Min Spring Preload Begin Min Spring Preload End Least Available Test Ambient Temp Close Test Information Test Motor Voltage Close Test D/P Close Test Pressure Close Test Flow Close Test System Temp Close Test System Temp Open Test Ambient Temp Open Test D/P Open Test Pressure Open Test Flow Open Test Motor Voltage Open

% Uncertainty Applied Valve Factor Measure Open Valve Factor Available Close Test Torque Close Test Thrust Open Test Torque Open Valve Factor Measured Close LSB Measured Bearing COF Measured Close Valve Factor Available Open Stem COF Measured Close Stem COF Measured Open Bearing COF Measured Open Test Thrust Close POV Qualifying Basis

% Margin Close

% Margin Open Design Basis Comments:

ft-lbs ft-lbs lbs lbs psig gpm psig gpm psig psig psig psig psig psig psig psig psig psig gpm OF OF psig psig gpm OF OF ft-lbs ft-lbs lbs lbs lbs

Docket 296 PLANT Browns Ferry 3 Valve ID 3-FCV-1-14 Date POV Inspection 07/18/2022

System Description

Main Steam - MS LN A INBD ISOL Size (inches) 26 Actuator Manufacturer Actuator Model Motor Size Design D/P Close Valve Information Actuator Information Valve Type Globe Valve Manufacturer Safety Function Close ASME Class Risk Motor Type Motor Manufacturer Control Switch Trip Close Control Switch Trip Open POV Type AOV ft-lbs Design Information Design D/P Open Required Thrust Close Required Torque Close Required Thrust Open Required Torque Open Design Flow Open Design Flow Close Valve Factor Assumed Close Valve Factor Assumed Open Min Air End Stroke (AOV)

Max Air Begin Stroke (AOV)

Stem COF Assumed LSB Assumed (percent)

Bearing COF Assumed (AOV)

Min Air Begin Stroke (AOV)

Max Spring Preload Begin Max Spring Preload End Max Air End Stroke (AOV)

Min Spring Preload Begin Min Spring Preload End Least Available Test Ambient Temp Close Test Information Test Motor Voltage Close Test D/P Close Test Pressure Close Test Flow Close Test System Temp Close Test System Temp Open Test Ambient Temp Open Test D/P Open Test Pressure Open Test Flow Open Test Motor Voltage Open

% Uncertainty Applied Valve Factor Measure Open Valve Factor Available Close Test Torque Close Test Thrust Open Test Torque Open Valve Factor Measured Close LSB Measured Bearing COF Measured Close Valve Factor Available Open Stem COF Measured Close Stem COF Measured Open Bearing COF Measured Open Test Thrust Close POV Qualifying Basis

% Margin Close

% Margin Open Design Basis Comments:

ft-lbs ft-lbs lbs lbs psig gpm psig gpm psig psig psig psig psig psig psig psig psig psig gpm OF OF psig psig gpm OF OF ft-lbs ft-lbs lbs lbs lbs

Docket 296 PLANT Browns Ferry 3 Valve ID 3-FCV-1-55 Date POV Inspection 07/18/2022

System Description

Main Steam - MS DRN LN INBD ISOL Size (inches) 3 Actuator Manufacturer Actuator Model Motor Size Design D/P Close Valve Information Actuator Information Valve Type Gate Valve Manufacturer Safety Function Close ASME Class Risk Motor Type Motor Manufacturer Control Switch Trip Close Control Switch Trip Open POV Type MOV ft-lbs Design Information Design D/P Open Required Thrust Close Required Torque Close Required Thrust Open Required Torque Open Design Flow Open Design Flow Close Valve Factor Assumed Close Valve Factor Assumed Open Min Air End Stroke (AOV)

Max Air Begin Stroke (AOV)

Stem COF Assumed LSB Assumed (percent)

Bearing COF Assumed (AOV)

Min Air Begin Stroke (AOV)

Max Spring Preload Begin Max Spring Preload End Max Air End Stroke (AOV)

Min Spring Preload Begin Min Spring Preload End Least Available Test Ambient Temp Close Test Information Test Motor Voltage Close Test D/P Close Test Pressure Close Test Flow Close Test System Temp Close Test System Temp Open Test Ambient Temp Open Test D/P Open Test Pressure Open Test Flow Open Test Motor Voltage Open

% Uncertainty Applied Valve Factor Measure Open Valve Factor Available Close Test Torque Close Test Thrust Open Test Torque Open Valve Factor Measured Close LSB Measured Bearing COF Measured Close Valve Factor Available Open Stem COF Measured Close Stem COF Measured Open Bearing COF Measured Open Test Thrust Close POV Qualifying Basis

% Margin Close

% Margin Open Design Basis Comments:

ft-lbs ft-lbs lbs lbs psig gpm psig gpm psig psig psig psig psig psig psig psig psig psig gpm OF OF psig psig gpm OF OF ft-lbs ft-lbs lbs lbs lbs

Docket 296 PLANT Browns Ferry 3 Valve ID 3-FCV-23-34 Date POV Inspection 07/18/2022

System Description

Residual Heat Removal Service Water - RHR HTX A OUTLT Size (inches) 16 Actuator Manufacturer Actuator Model Motor Size Design D/P Close Valve Information Actuator Information Valve Type Globe Valve Manufacturer Safety Function Open/Close ASME Class Risk Motor Type Motor Manufacturer Control Switch Trip Close Control Switch Trip Open POV Type MOV ft-lbs Design Information Design D/P Open Required Thrust Close Required Torque Close Required Thrust Open Required Torque Open Design Flow Open Design Flow Close Valve Factor Assumed Close Valve Factor Assumed Open Min Air End Stroke (AOV)

Max Air Begin Stroke (AOV)

Stem COF Assumed LSB Assumed (percent)

Bearing COF Assumed (AOV)

Min Air Begin Stroke (AOV)

Max Spring Preload Begin Max Spring Preload End Max Air End Stroke (AOV)

Min Spring Preload Begin Min Spring Preload End Least Available Test Ambient Temp Close Test Information Test Motor Voltage Close Test D/P Close Test Pressure Close Test Flow Close Test System Temp Close Test System Temp Open Test Ambient Temp Open Test D/P Open Test Pressure Open Test Flow Open Test Motor Voltage Open

% Uncertainty Applied Valve Factor Measure Open Valve Factor Available Close Test Torque Close Test Thrust Open Test Torque Open Valve Factor Measured Close LSB Measured Bearing COF Measured Close Valve Factor Available Open Stem COF Measured Close Stem COF Measured Open Bearing COF Measured Open Test Thrust Close POV Qualifying Basis

% Margin Close

% Margin Open Design Basis Comments:

ft-lbs ft-lbs lbs lbs psig gpm psig gpm psig psig psig psig psig psig psig psig psig psig gpm OF OF psig psig gpm OF OF ft-lbs ft-lbs lbs lbs lbs

Docket 296 PLANT Browns Ferry 3 Valve ID 3-FCV-63-8A Date POV Inspection 07/18/2022

System Description

Standby Liquid Control - SLC PMP A INJ Size (inches) 1.5 Actuator Manufacturer Actuator Model Motor Size Design D/P Close Valve Information Actuator Information Valve Type Gate Valve Manufacturer Safety Function Open ASME Class Risk Motor Type Motor Manufacturer Control Switch Trip Close Control Switch Trip Open POV Type Squib ft-lbs Design Information Design D/P Open Required Thrust Close Required Torque Close Required Thrust Open Required Torque Open Design Flow Open Design Flow Close Valve Factor Assumed Close Valve Factor Assumed Open Min Air End Stroke (AOV)

Max Air Begin Stroke (AOV)

Stem COF Assumed LSB Assumed (percent)

Bearing COF Assumed (AOV)

Min Air Begin Stroke (AOV)

Max Spring Preload Begin Max Spring Preload End Max Air End Stroke (AOV)

Min Spring Preload Begin Min Spring Preload End Least Available Test Ambient Temp Close Test Information Test Motor Voltage Close Test D/P Close Test Pressure Close Test Flow Close Test System Temp Close Test System Temp Open Test Ambient Temp Open Test D/P Open Test Pressure Open Test Flow Open Test Motor Voltage Open

% Uncertainty Applied Valve Factor Measure Open Valve Factor Available Close Test Torque Close Test Thrust Open Test Torque Open Valve Factor Measured Close LSB Measured Bearing COF Measured Close Valve Factor Available Open Stem COF Measured Close Stem COF Measured Open Bearing COF Measured Open Test Thrust Close POV Qualifying Basis

% Margin Close

% Margin Open Design Basis Comments:

ft-lbs ft-lbs lbs lbs psig gpm psig gpm psig psig psig psig psig psig psig psig psig psig gpm OF OF psig psig gpm OF OF ft-lbs ft-lbs lbs lbs lbs

Docket 296 PLANT Browns Ferry 3 Valve ID 3-FCV-67-50 Date POV Inspection 07/18/2022

System Description

Emergency Equipment Cooling Water System -

EECW N HDR TO RBCCW HTX Size (inches) 8 Actuator Manufacturer Actuator Model Motor Size Design D/P Close Valve Information Actuator Information Valve Type Butterfly Valve Manufacturer Safety Function Close ASME Class Risk Motor Type Motor Manufacturer Control Switch Trip Close Control Switch Trip Open POV Type AOV ft-lbs Design Information Design D/P Open Required Thrust Close Required Torque Close Required Thrust Open Required Torque Open Design Flow Open Design Flow Close Valve Factor Assumed Close Valve Factor Assumed Open Min Air End Stroke (AOV)

Max Air Begin Stroke (AOV)

Stem COF Assumed LSB Assumed (percent)

Bearing COF Assumed (AOV)

Min Air Begin Stroke (AOV)

Max Spring Preload Begin Max Spring Preload End Max Air End Stroke (AOV)

Min Spring Preload Begin Min Spring Preload End Least Available Test Ambient Temp Close Test Information Test Motor Voltage Close Test D/P Close Test Pressure Close Test Flow Close Test System Temp Close Test System Temp Open Test Ambient Temp Open Test D/P Open Test Pressure Open Test Flow Open Test Motor Voltage Open

% Uncertainty Applied Valve Factor Measure Open Valve Factor Available Close Test Torque Close Test Thrust Open Test Torque Open Valve Factor Measured Close LSB Measured Bearing COF Measured Close Valve Factor Available Open Stem COF Measured Close Stem COF Measured Open Bearing COF Measured Open Test Thrust Close POV Qualifying Basis

% Margin Close

% Margin Open Design Basis Comments:

ft-lbs ft-lbs lbs lbs psig gpm psig gpm psig psig psig psig psig psig psig psig psig psig gpm OF OF psig psig gpm OF OF ft-lbs ft-lbs lbs lbs lbs

Docket 296 PLANT Browns Ferry 3 Valve ID 3-FCV-73-16 Date POV Inspection 07/18/2022

System Description

High Pressure Coolant Injection - HPCI TRB STM SPLY VLV Size (inches) 10 Actuator Manufacturer Actuator Model Motor Size Design D/P Close Valve Information Actuator Information Valve Type Gate Valve Manufacturer Safety Function Open ASME Class Risk Motor Type Motor Manufacturer Control Switch Trip Close Control Switch Trip Open POV Type MOV ft-lbs Design Information Design D/P Open Required Thrust Close Required Torque Close Required Thrust Open Required Torque Open Design Flow Open Design Flow Close Valve Factor Assumed Close Valve Factor Assumed Open Min Air End Stroke (AOV)

Max Air Begin Stroke (AOV)

Stem COF Assumed LSB Assumed (percent)

Bearing COF Assumed (AOV)

Min Air Begin Stroke (AOV)

Max Spring Preload Begin Max Spring Preload End Max Air End Stroke (AOV)

Min Spring Preload Begin Min Spring Preload End Least Available Test Ambient Temp Close Test Information Test Motor Voltage Close Test D/P Close Test Pressure Close Test Flow Close Test System Temp Close Test System Temp Open Test Ambient Temp Open Test D/P Open Test Pressure Open Test Flow Open Test Motor Voltage Open

% Uncertainty Applied Valve Factor Measure Open Valve Factor Available Close Test Torque Close Test Thrust Open Test Torque Open Valve Factor Measured Close LSB Measured Bearing COF Measured Close Valve Factor Available Open Stem COF Measured Close Stem COF Measured Open Bearing COF Measured Open Test Thrust Close POV Qualifying Basis

% Margin Close

% Margin Open Design Basis Comments:

ft-lbs ft-lbs lbs lbs psig gpm psig gpm psig psig psig psig psig psig psig psig psig psig gpm OF OF psig psig gpm OF OF ft-lbs ft-lbs lbs lbs lbs

Docket 296 PLANT Browns Ferry 3 Valve ID 3-FCV-73-26 Date POV Inspection 07/18/2022

System Description

High Pressure Coolant Injection - PSC TO HPCI INBD ISOL Size (inches) 16 Actuator Manufacturer Actuator Model Motor Size Design D/P Close Valve Information Actuator Information Valve Type Gate Valve Manufacturer Safety Function Open/Close ASME Class Risk Motor Type Motor Manufacturer Control Switch Trip Close Control Switch Trip Open POV Type MOV ft-lbs Design Information Design D/P Open Required Thrust Close Required Torque Close Required Thrust Open Required Torque Open Design Flow Open Design Flow Close Valve Factor Assumed Close Valve Factor Assumed Open Min Air End Stroke (AOV)

Max Air Begin Stroke (AOV)

Stem COF Assumed LSB Assumed (percent)

Bearing COF Assumed (AOV)

Min Air Begin Stroke (AOV)

Max Spring Preload Begin Max Spring Preload End Max Air End Stroke (AOV)

Min Spring Preload Begin Min Spring Preload End Least Available Test Ambient Temp Close Test Information Test Motor Voltage Close Test D/P Close Test Pressure Close Test Flow Close Test System Temp Close Test System Temp Open Test Ambient Temp Open Test D/P Open Test Pressure Open Test Flow Open Test Motor Voltage Open

% Uncertainty Applied Valve Factor Measure Open Valve Factor Available Close Test Torque Close Test Thrust Open Test Torque Open Valve Factor Measured Close LSB Measured Bearing COF Measured Close Valve Factor Available Open Stem COF Measured Close Stem COF Measured Open Bearing COF Measured Open Test Thrust Close POV Qualifying Basis

% Margin Close

% Margin Open Design Basis Comments:

ft-lbs ft-lbs lbs lbs psig gpm psig gpm psig psig psig psig psig psig psig psig psig psig gpm OF OF psig psig gpm OF OF ft-lbs ft-lbs lbs lbs lbs

Docket 296 PLANT Browns Ferry 3 Valve ID 3-FCV-74-71 Date POV Inspection 07/18/2022

System Description

Residual Heat Removal System - RHR LOOP II PSC RTN Size (inches) 18 Actuator Manufacturer Actuator Model Motor Size Design D/P Close Valve Information Actuator Information Valve Type Gate Valve Manufacturer Safety Function Open/Close ASME Class Risk Motor Type Motor Manufacturer Control Switch Trip Close Control Switch Trip Open POV Type MOV ft-lbs Design Information Design D/P Open Required Thrust Close Required Torque Close Required Thrust Open Required Torque Open Design Flow Open Design Flow Close Valve Factor Assumed Close Valve Factor Assumed Open Min Air End Stroke (AOV)

Max Air Begin Stroke (AOV)

Stem COF Assumed LSB Assumed (percent)

Bearing COF Assumed (AOV)

Min Air Begin Stroke (AOV)

Max Spring Preload Begin Max Spring Preload End Max Air End Stroke (AOV)

Min Spring Preload Begin Min Spring Preload End Least Available Test Ambient Temp Close Test Information Test Motor Voltage Close Test D/P Close Test Pressure Close Test Flow Close Test System Temp Close Test System Temp Open Test Ambient Temp Open Test D/P Open Test Pressure Open Test Flow Open Test Motor Voltage Open

% Uncertainty Applied Valve Factor Measure Open Valve Factor Available Close Test Torque Close Test Thrust Open Test Torque Open Valve Factor Measured Close LSB Measured Bearing COF Measured Close Valve Factor Available Open Stem COF Measured Close Stem COF Measured Open Bearing COF Measured Open Test Thrust Close POV Qualifying Basis

% Margin Close

% Margin Open Design Basis Comments:

ft-lbs ft-lbs lbs lbs psig gpm psig gpm psig psig psig psig psig psig psig psig psig psig gpm OF OF psig psig gpm OF OF ft-lbs ft-lbs lbs lbs lbs

Docket 296 PLANT Browns Ferry 3 Valve ID 3-FCV-75-53 Date POV Inspection 07/18/2022

System Description

Core Spray Cooling System - CS LOOP II INJ Size (inches) 12 Actuator Manufacturer Actuator Model Motor Size Design D/P Close Valve Information Actuator Information Valve Type Gate Valve Manufacturer Safety Function Open/Close ASME Class Risk Motor Type Motor Manufacturer Control Switch Trip Close Control Switch Trip Open POV Type MOV ft-lbs Design Information Design D/P Open Required Thrust Close Required Torque Close Required Thrust Open Required Torque Open Design Flow Open Design Flow Close Valve Factor Assumed Close Valve Factor Assumed Open Min Air End Stroke (AOV)

Max Air Begin Stroke (AOV)

Stem COF Assumed LSB Assumed (percent)

Bearing COF Assumed (AOV)

Min Air Begin Stroke (AOV)

Max Spring Preload Begin Max Spring Preload End Max Air End Stroke (AOV)

Min Spring Preload Begin Min Spring Preload End Least Available Test Ambient Temp Close Test Information Test Motor Voltage Close Test D/P Close Test Pressure Close Test Flow Close Test System Temp Close Test System Temp Open Test Ambient Temp Open Test D/P Open Test Pressure Open Test Flow Open Test Motor Voltage Open

% Uncertainty Applied Valve Factor Measure Open Valve Factor Available Close Test Torque Close Test Thrust Open Test Torque Open Valve Factor Measured Close LSB Measured Bearing COF Measured Close Valve Factor Available Open Stem COF Measured Close Stem COF Measured Open Bearing COF Measured Open Test Thrust Close POV Qualifying Basis

% Margin Close

% Margin Open Design Basis Comments:

ft-lbs ft-lbs lbs lbs psig gpm psig gpm psig psig psig psig psig psig psig psig psig psig gpm OF OF psig psig gpm OF OF ft-lbs ft-lbs lbs lbs lbs

Docket 296 PLANT Browns Ferry 3 Valve ID 3-FCV-75-57 Date POV Inspection 07/18/2022

System Description

Core Spray Cooling System - CS DRN PMP A INBD ISOL Size (inches) 3 Actuator Manufacturer Actuator Model Motor Size Design D/P Close Valve Information Actuator Information Valve Type Globe Valve Manufacturer Safety Function Close ASME Class Risk Motor Type Motor Manufacturer Control Switch Trip Close Control Switch Trip Open POV Type AOV ft-lbs Design Information Design D/P Open Required Thrust Close Required Torque Close Required Thrust Open Required Torque Open Design Flow Open Design Flow Close Valve Factor Assumed Close Valve Factor Assumed Open Min Air End Stroke (AOV)

Max Air Begin Stroke (AOV)

Stem COF Assumed LSB Assumed (percent)

Bearing COF Assumed (AOV)

Min Air Begin Stroke (AOV)

Max Spring Preload Begin Max Spring Preload End Max Air End Stroke (AOV)

Min Spring Preload Begin Min Spring Preload End Least Available Test Ambient Temp Close Test Information Test Motor Voltage Close Test D/P Close Test Pressure Close Test Flow Close Test System Temp Close Test System Temp Open Test Ambient Temp Open Test D/P Open Test Pressure Open Test Flow Open Test Motor Voltage Open

% Uncertainty Applied Valve Factor Measure Open Valve Factor Available Close Test Torque Close Test Thrust Open Test Torque Open Valve Factor Measured Close LSB Measured Bearing COF Measured Close Valve Factor Available Open Stem COF Measured Close Stem COF Measured Open Bearing COF Measured Open Test Thrust Close POV Qualifying Basis

% Margin Close

% Margin Open Design Basis Comments:

ft-lbs ft-lbs lbs lbs psig gpm psig gpm psig psig psig psig psig psig psig psig psig psig gpm OF OF psig psig gpm OF OF ft-lbs ft-lbs lbs lbs lbs