MONTHYEARML0917402832009-07-10010 July 2009 University of Missouri at Columbia - Request for Additional Information License Renewal Project stage: RAI ML12355A0192010-09-30030 September 2010 University of Missouri, Columbia - *Redacted* Response to NRC Request for Additional Information Dated June 1, 2010 Project stage: Response to RAI ML12355A0232010-10-29029 October 2010 University of Missouri, Columbia - (Redacted) Response to NRC Request for Additional Information 45-Day Response Questions Project stage: Response to RAI ML1202400382012-01-23023 January 2012 University of Missouri, Columbia - E-mail from L. Foyto, Associate Director, to G. Wertz, NRC Project Manager Extension Request for the Remaining 45-Day and 120-Day Responses Project stage: Request ML1202600142012-01-26026 January 2012 University of Missouri - Approval of Request for Additional Time to Respond to NRC Request for Additional Information License Renewal Project stage: RAI ML12346A0042012-06-28028 June 2012 University of Missouri, Columbia - *Redacted* Licensee Response to NRC Request for Additional Information Dated May 6, 2010 (Complex Questions) and June 1, 2012 (45-Day Response Questions) License Renewal Project stage: Response to RAI ML12355A0632012-12-20020 December 2012 University of Missouri, Columbia - Request for a Copy of the Physical Security Plan and Operator Requalification Program, License Renewal (Tac No. ME1580) Project stage: Other ML13031A1572013-02-11011 February 2013 University of Missouri, Columbia - Request for Additional Information Updated Financial Information for License Renewal Project stage: RAI ML13079A2162013-02-28028 February 2013 Letter from Kelly Mescher the Court in Sherman V. the Curators of the University of Missouri Project stage: Other ML13079A2152013-03-0505 March 2013 Statement of Intent Project stage: Other ML13079A2182013-03-12012 March 2013 University of Missouri System 2012 Financial Report Project stage: Other ML13079A2142013-03-12012 March 2013 Written Communication as Specified by 10 CFR 50.4(b)(1) Regarding the Response to the University of Missouri at Columbia - Request for Additional Information Updated Financial Information for License Renewal (TAC No. ME1580), Dated 02/11/20 Project stage: Request ML13079A2172013-03-12012 March 2013 Letter from Ralph A. Butler Enclosed with University of Missouri-Columbia Research Reactors Responses to the U.S. Nuclear Regulatory Commissions (NRC) Request for Additional Information, Dated February 11, 2013, Regarding Our Renewal Reques Project stage: Request ML13098A0512013-04-0909 April 2013 University of Missouri, Columbia - NRC Staff Review of the Operator Requalification Program License Renewal (Tac No. ME1580) Project stage: Approval ML13099A1142013-05-0606 May 2013 University of Missouri, Columbia - Letter to Licensee Determination of Acceptability for Docketing the Application for License Renewal Project stage: Other ML13099A1402013-05-14014 May 2013 FRN: General Notice: University of Missouri, Columbia - Notice of Acceptability for Docketing and Hearing Opportunity License Renewal (Tac No. ME1580) Project stage: Other ML14324A7072014-12-0303 December 2014 Request for Additional Information Regarding the MURR License Renewal Review (Updated Info 11/19/2014) Project stage: RAI ML15034A4742015-01-28028 January 2015 Written Communication as Specified by 10 CFR 50.4(b)(1) Regarding the Response to the University of Missouri at Columbia - Request for Additional Information Regarding the Renewal of Facility Operating License No. R-103 for the University O Project stage: Request ML15034A4732015-01-28028 January 2015 University of Missouri-Columbia Research Reactor Response to NRC Request for Additional Information Re License Renewal Application Project stage: Response to RAI ML15049A0392015-02-12012 February 2015 University of Missouri-Columbia - Response to Request for Additional Information Regarding the Renewal of Facility Operating License No. R- 103 Dated December.3, 2014 Project stage: Response to RAI ML15051A0042015-02-20020 February 2015 University of Missouri at Columbia, Request for Withholding Information from Public Disclosure Project stage: Withholding Request Acceptance ML15098A6482015-04-17017 April 2015 University of Missouri at Columbia - Request for Additional Information Regarding the Renewal of Facility Operating License No. R-103 for the University of Missouri at Columbia Research Reactor Project stage: RAI ML15183A4612015-05-11011 May 2015 Federal Funding for the Conversion of the University of Missouri-Columbia Research Reactor from Highly-Enriched Uranium Fuel to Low-Enriched Uranium Fuel Project stage: Request ML15162A0982015-06-18018 June 2015 University of Missouri at Columbia - RAI Regarding the Renewal of Facility Operating License No. R-103 for the University of Missouri at Columbia Research Reactor Project stage: RAI ML15154B8122015-07-21021 July 2015 University of Missouri at Columbia Acknowledgement of the Imposition of an Administrative Limit for the Quantity of Iodine Processed in the Iodine Processing Laboratory Hot Cells for Facility Operating License No. R 103 Project stage: Other ML15216A1222015-07-31031 July 2015 University of Missouri-Columbia - Response to Request for Additional Information Regarding Renewal Request for Amended Facility Operating License Project stage: Response to RAI ML15224B3092015-09-14014 September 2015 University of Missouri at Columbia - Request for Additional Information Regarding, Physical Security Plan Review for Renewal of Facility Operating License No. R-103 for the University of Missouri at Columbia Research Reactor Project stage: RAI ML15260A4392015-09-15015 September 2015 University of Missouri-Columbia - Request for a Copy of the Emergency Plan in Support of the Renewal of Amended Facility License No. R-103 Project stage: Request ML15275A3132015-10-0101 October 2015 University of Missouri-Columbia - Transmittal of Responses to NRC Request for Additional Information, Dated April 17, 2015, Regarding Renewal Request for Amended Facility Operating License Project stage: Response to RAI ML15275A3142015-10-0101 October 2015 University of Missouri, Columbia - Responses to NRC Request for Additional Information, Dated April 17, 2015, Regarding Renewal Request for Amended Facility Operating License Project stage: Response to RAI ML15350A0882015-10-0606 October 2015 State of Missouri, Federal Assistance Clearinghouse Letter NRC Request for Additional Info Regarding the Physical Security Plan Review for Renewal of Facility Operating License No.R-103 for the Univ. of Missouri at Columbia Research Reactor Project stage: Request ML15280A3142015-10-28028 October 2015 University of Missouri at Columbia Research Reactor Request for Additional Information Regarding the Proposed Technical Specifications for the Murr License Renewal Review Project stage: RAI ML15344A0232015-12-0202 December 2015 University of Missouri(Um) at Columbia - Response to Request for Additional Information Regarding Physical Security Plan Review for Renewal of Facility Operating License No. R-103 for the Um at Columbia Research Reactor Project stage: Response to RAI ML15331A0492015-12-0909 December 2015 University of Missouri at Columbia Review of the Emergency Plan in Support of the License Renewal Project stage: Approval ML15337A1752015-12-17017 December 2015 University of Missouri at Columbia Clarifications Needed to NRC Staff Request for Additional Information Regarding the Renewal of Facility Operating License No. R-103 for the University of Missouri at Columbia Research Reactor Project stage: RAI ML16041A2212016-02-0808 February 2016 Univ. of Missouri-Columbia - Response to NRC Request for Additional Information Dated December17, 2015, Regarding Renewal Request for License No. R-103 Project stage: Response to RAI ML16028A2552016-02-0808 February 2016 University of Missouri at Columbia; Request for Additional Information Updated Financial Information for Renewal of Facility Operating License No. R-103 for the University of Missouri at Columbia Research Reactor (Tac No. Me1580) Project stage: RAI ML16083A0252016-03-23023 March 2016 University of Missouri at Columbia - Clarifications Needed to Nuclear Regulatory Commission Staff Request for Additional Information Regarding the Renewal of Facility Operating License No. R-103 Project stage: RAI ML16103A5302016-04-0808 April 2016 Univ. of Missouri, Columbia - Transmittal of Responses to NRC Request for Additional Information Dated February 8, 2016 Regarding Renewal Request for Amendment Project stage: Response to RAI ML16110A1632016-04-15015 April 2016 University of Missouri - Columbia Research Reactor, Response to Request for Additional Information on License Renewal Amendment Request Project stage: Response to RAI ML16110A1642016-04-15015 April 2016 University of Missouri - Columbia Research Reactor, Response to Request for Additional Information on License Renewal Amendment Request Project stage: Response to RAI ML16155A1322016-05-31031 May 2016 University of Missouri-Columbia Research Reactors Responses to the NRC Request for Additional Information, Dated October 28, 2015, Regarding Our Renewal Request for Amended Facility Operating License No. R-103 Project stage: Request ML16209A2362016-07-25025 July 2016 University of Missouri, Response to Request for Additional Information Regarding the Proposed Technical Specifications for the License Renewal Project stage: Response to RAI ML16209A2352016-07-25025 July 2016 University of Missouri - Columbia Research Reactor, Response to Request for Additional Information Regarding License Renewal Request Project stage: Response to RAI ML16216A1222016-08-24024 August 2016 University of Missouri at Columbia - Request for Additional Information Financial Information for Renewal of Facility Operating License No. R-103 for the University of Missouri at Columbia Research Reactor Project stage: RAI ML16246A0102016-08-31031 August 2016 University of Missouri - Columbia, Response to NRC Request for Additional Information Regarding Renewal for Amended Facility Operating License Project stage: Response to RAI ML16246A0082016-08-31031 August 2016 University of Missouri - Columbia, Submittal of Response to NRC Request for Additional Information Regarding Renewal for Amended Facility Operating License Project stage: Response to RAI ML16239A4252016-09-0707 September 2016 University of Missouri at Columbia - Request for Additional Information Regarding the Proposed Technical Specifications for the Renewal of Facility Operating License No. R-103 for the University of Missouri at Columbia Research Reactor Project stage: RAI ML16313A5172016-11-0707 November 2016 University If Missouri, Response to NRC Request for RAI, Dated September 7, 2016 Regarding License Renewal Amendment Project stage: Request ML16321A4852016-11-15015 November 2016 University of Missouri-Columbia Research Reactor - Response to Request for Additional Information Regarding License Renewal Request Project stage: Response to RAI 2015-12-02
[Table View] |
Text
July 21, 2015 Mr. Ralph Butler, Director Research Reactor Center University of Missouri-Columbia Research Park Columbia, MO 65211
SUBJECT:
UNIVERSITY OF MISSOURI AT COLUMBIA - ACKNOWLEDGEMENT OF AN ADMINISTRATIVE LIMIT FOR THE QUANTITY OF IODINE PROCESSED IN THE IODINE PROCESSING LABORATORY HOT CELLS FOR FACILITY OPERATING LICENSE NO. R-103 FOR THE UNIVERSITY OF MISSOURI AT COLUMBIA RESEARCH REACTOR (TAC NO. ME1580)
Dear Mr. Butler:
As part of the license renewal process for the University of Missouri at Columbia, Research Reactor (MURR), the U.S. Nuclear Regulatory Commission (NRC) staff reviewed your response to our request for additional information dated January 28, 2015, describing the I-131 Processing Laboratory, Attachment No. 25 (although portions of this system are considered proprietary, a public version, where proprietary information has been redacted, is available on the Agencywide Documents Access and Management System (ADAMS) Accession No. ML15034A474). NRC Headquarters inspectors reviewed the I-131 Processing Laboratory during a routine inspection conducted from March 30 through April 2, 2015, and documented their findings in NRC Inspection Report No. 50-186/2015-201 (ADAMS Accession No. ML15120A338). An Unresolved Item No. 50-186/2015-201-01 was issued to provide for additional NRC staff review. NRC Research and Test Reactor Licensing branch staff visited the facility on May 12-13, 2015, as part of their review of the renewal of the MURR facility operating license, and also reviewed the I-131 Processing Laboratory.
Following these additional reviews, the NRC staff conducted a telephone conversation on May 28, 2015, between MURR staff: Mr. Les Foyto, and Mr. John Fruits, and NRC staff:
Dr. Mirela Gavrilas, Mr. Alexander Adams, Jr., Dr. Kevin Hsueh, Mr. John Adams, Mr. Johnny Eades, and Mr. Geoffrey Wertz. During this telephone call, the NRC staff communicated that it appears that additional safety review is necessary in order to determine if any engineered safety features, automated control systems, or additional technical specifications should be required during the operation of the I-131 Processing Laboratory to ensure that any accident scenario could not result in a dose consequence greater than the limits provided in Title 10 of the Code of Federal Regulations (10 CFR), Part 20, Standards for Protection Against Radiation. As a result, MURR staff decided to limit the iodine production in the hot cells to less than allowed by current MURR technical specification 3.7 and 10 CFR Part 20, Appendix B. Confirmation of this understanding was provided by an email from Mr. Les Foyto to Mr. Geoffrey Wertz (ADAMS Accession No. ML15154B803), dated May 28, 2015.
Please notify me immediately if your understanding differs from what is set forth above or if for any reason you intend to change, deviate from or not complete any of the actions set forth above, and advise me of the changes or deviations.
R. Butler Be advised this letter does not preclude issuance of an order formalizing the above commitments or requiring other actions on the part of the licensee, nor does it preclude the NRC from taking enforcement action for violations of NRC requirements that may have prompted the issuance of this letter.
In accordance with 10 CFR, Section 2.390, "Public inspections, exemptions, requests for withholding," a copy of this letter, and your response, if you choose to provide one, will be made available electronically for public inspection in the NRC Public Document Room and in ADAMS, accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html. To the extent possible, your response should not include any personal privacy, proprietary, or safeguards information so that it can be made available to the public without redaction. If personal privacy or proprietary information is necessary to provide an acceptable response, then please provide a bracketed copy of your response that identifies the information that should be protected and a redacted copy of your response that deletes such information. If you request withholding of such material, you must specifically identify the portions of your response that you seek to have withheld, and provide in detail the bases for your claim of withholding (e.g., explain why the disclosure of information will create an unwarranted invasion of personal privacy or provide the information required by 10 CFR 2.390(b) to support a request for withholding confidential commercial or financial information).
If you have any questions regarding this review, please contact Mr. Geoffrey Wertz at (301) 415-0893, or by e-mail at Geoffrey.Wertz@nrc.gov.
Sincerely,
/RA/
Mirela Gavrilas, Deputy Director Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No. 50-186 cc: See next page
University of Missouri-Columbia Docket No. 50-186 cc:
Mr. Les Foyto, Associate Director Reactor and Facilities Operations Research Reactor Center University of Missouri - Columbia Research Park Columbia, MO 65211 Homeland Security Coordinator Missouri Office of Homeland Security P.O. Box 749 Jefferson City, MO 65102 Planner, Dept. of Health and Senior Services Section for Environmental Public Health 930 Wildwood Drive, P.O. Box 570 Jefferson City, MO 65102-0570 Deputy Director for Policy Department of Natural Resources 1101 Riverside Drive Fourth Floor East Jefferson City, MO 65101 A-95 Coordinator Division of Planning Office of Administration P.O. Box 809, State Capitol Building Jefferson City, MO 65101 Test, Research, and Training Reactor Newsletter University of Florida 202 Nuclear Sciences Center Gainesville, FL 32611
(Pkg.) ML15154B830; (Letter) ML15154B812; (E-mail) ML15154B803;
- concurred via email NRR-088