MONTHYEARML0917402832009-07-10010 July 2009 University of Missouri at Columbia - Request for Additional Information License Renewal Project stage: RAI ML12355A0192010-09-30030 September 2010 University of Missouri, Columbia - *Redacted* Response to NRC Request for Additional Information Dated June 1, 2010 Project stage: Response to RAI ML12355A0232010-10-29029 October 2010 University of Missouri, Columbia - (Redacted) Response to NRC Request for Additional Information 45-Day Response Questions Project stage: Response to RAI ML1202400382012-01-23023 January 2012 University of Missouri, Columbia - E-mail from L. Foyto, Associate Director, to G. Wertz, NRC Project Manager Extension Request for the Remaining 45-Day and 120-Day Responses Project stage: Request ML1202600142012-01-26026 January 2012 University of Missouri - Approval of Request for Additional Time to Respond to NRC Request for Additional Information License Renewal Project stage: RAI ML12346A0042012-06-28028 June 2012 University of Missouri, Columbia - *Redacted* Licensee Response to NRC Request for Additional Information Dated May 6, 2010 (Complex Questions) and June 1, 2012 (45-Day Response Questions) License Renewal Project stage: Response to RAI ML12355A0632012-12-20020 December 2012 University of Missouri, Columbia - Request for a Copy of the Physical Security Plan and Operator Requalification Program, License Renewal (Tac No. ME1580) Project stage: Other ML13031A1572013-02-11011 February 2013 University of Missouri, Columbia - Request for Additional Information Updated Financial Information for License Renewal Project stage: RAI ML13079A2162013-02-28028 February 2013 Letter from Kelly Mescher the Court in Sherman V. the Curators of the University of Missouri Project stage: Other ML13079A2152013-03-0505 March 2013 Statement of Intent Project stage: Other ML13079A2182013-03-12012 March 2013 University of Missouri System 2012 Financial Report Project stage: Other ML13079A2142013-03-12012 March 2013 Written Communication as Specified by 10 CFR 50.4(b)(1) Regarding the Response to the University of Missouri at Columbia - Request for Additional Information Updated Financial Information for License Renewal (TAC No. ME1580), Dated 02/11/20 Project stage: Request ML13079A2172013-03-12012 March 2013 Letter from Ralph A. Butler Enclosed with University of Missouri-Columbia Research Reactors Responses to the U.S. Nuclear Regulatory Commissions (NRC) Request for Additional Information, Dated February 11, 2013, Regarding Our Renewal Reques Project stage: Request ML13098A0512013-04-0909 April 2013 University of Missouri, Columbia - NRC Staff Review of the Operator Requalification Program License Renewal (Tac No. ME1580) Project stage: Approval ML13099A1142013-05-0606 May 2013 University of Missouri, Columbia - Letter to Licensee Determination of Acceptability for Docketing the Application for License Renewal Project stage: Other ML13099A1402013-05-14014 May 2013 FRN: General Notice: University of Missouri, Columbia - Notice of Acceptability for Docketing and Hearing Opportunity License Renewal (Tac No. ME1580) Project stage: Other ML14324A7072014-12-0303 December 2014 Request for Additional Information Regarding the MURR License Renewal Review (Updated Info 11/19/2014) Project stage: RAI ML15034A4742015-01-28028 January 2015 Written Communication as Specified by 10 CFR 50.4(b)(1) Regarding the Response to the University of Missouri at Columbia - Request for Additional Information Regarding the Renewal of Facility Operating License No. R-103 for the University O Project stage: Request ML15034A4732015-01-28028 January 2015 University of Missouri-Columbia Research Reactor Response to NRC Request for Additional Information Re License Renewal Application Project stage: Response to RAI ML15049A0392015-02-12012 February 2015 University of Missouri-Columbia - Response to Request for Additional Information Regarding the Renewal of Facility Operating License No. R- 103 Dated December.3, 2014 Project stage: Response to RAI ML15051A0042015-02-20020 February 2015 University of Missouri at Columbia, Request for Withholding Information from Public Disclosure Project stage: Withholding Request Acceptance ML15098A6482015-04-17017 April 2015 University of Missouri at Columbia - Request for Additional Information Regarding the Renewal of Facility Operating License No. R-103 for the University of Missouri at Columbia Research Reactor Project stage: RAI ML15183A4612015-05-11011 May 2015 Federal Funding for the Conversion of the University of Missouri-Columbia Research Reactor from Highly-Enriched Uranium Fuel to Low-Enriched Uranium Fuel Project stage: Request ML15162A0982015-06-18018 June 2015 University of Missouri at Columbia - RAI Regarding the Renewal of Facility Operating License No. R-103 for the University of Missouri at Columbia Research Reactor Project stage: RAI ML15154B8122015-07-21021 July 2015 University of Missouri at Columbia Acknowledgement of the Imposition of an Administrative Limit for the Quantity of Iodine Processed in the Iodine Processing Laboratory Hot Cells for Facility Operating License No. R 103 Project stage: Other ML15216A1222015-07-31031 July 2015 University of Missouri-Columbia - Response to Request for Additional Information Regarding Renewal Request for Amended Facility Operating License Project stage: Response to RAI ML15224B3092015-09-14014 September 2015 University of Missouri at Columbia - Request for Additional Information Regarding, Physical Security Plan Review for Renewal of Facility Operating License No. R-103 for the University of Missouri at Columbia Research Reactor Project stage: RAI ML15260A4392015-09-15015 September 2015 University of Missouri-Columbia - Request for a Copy of the Emergency Plan in Support of the Renewal of Amended Facility License No. R-103 Project stage: Request ML15275A3132015-10-0101 October 2015 University of Missouri-Columbia - Transmittal of Responses to NRC Request for Additional Information, Dated April 17, 2015, Regarding Renewal Request for Amended Facility Operating License Project stage: Response to RAI ML15275A3142015-10-0101 October 2015 University of Missouri, Columbia - Responses to NRC Request for Additional Information, Dated April 17, 2015, Regarding Renewal Request for Amended Facility Operating License Project stage: Response to RAI ML15350A0882015-10-0606 October 2015 State of Missouri, Federal Assistance Clearinghouse Letter NRC Request for Additional Info Regarding the Physical Security Plan Review for Renewal of Facility Operating License No.R-103 for the Univ. of Missouri at Columbia Research Reactor Project stage: Request ML15280A3142015-10-28028 October 2015 University of Missouri at Columbia Research Reactor Request for Additional Information Regarding the Proposed Technical Specifications for the Murr License Renewal Review Project stage: RAI ML15344A0232015-12-0202 December 2015 University of Missouri(Um) at Columbia - Response to Request for Additional Information Regarding Physical Security Plan Review for Renewal of Facility Operating License No. R-103 for the Um at Columbia Research Reactor Project stage: Response to RAI ML15331A0492015-12-0909 December 2015 University of Missouri at Columbia Review of the Emergency Plan in Support of the License Renewal Project stage: Approval ML15337A1752015-12-17017 December 2015 University of Missouri at Columbia Clarifications Needed to NRC Staff Request for Additional Information Regarding the Renewal of Facility Operating License No. R-103 for the University of Missouri at Columbia Research Reactor Project stage: RAI ML16041A2212016-02-0808 February 2016 Univ. of Missouri-Columbia - Response to NRC Request for Additional Information Dated December17, 2015, Regarding Renewal Request for License No. R-103 Project stage: Response to RAI ML16028A2552016-02-0808 February 2016 University of Missouri at Columbia; Request for Additional Information Updated Financial Information for Renewal of Facility Operating License No. R-103 for the University of Missouri at Columbia Research Reactor (Tac No. Me1580) Project stage: RAI ML16083A0252016-03-23023 March 2016 University of Missouri at Columbia - Clarifications Needed to Nuclear Regulatory Commission Staff Request for Additional Information Regarding the Renewal of Facility Operating License No. R-103 Project stage: RAI ML16103A5302016-04-0808 April 2016 Univ. of Missouri, Columbia - Transmittal of Responses to NRC Request for Additional Information Dated February 8, 2016 Regarding Renewal Request for Amendment Project stage: Response to RAI ML16110A1632016-04-15015 April 2016 University of Missouri - Columbia Research Reactor, Response to Request for Additional Information on License Renewal Amendment Request Project stage: Response to RAI ML16110A1642016-04-15015 April 2016 University of Missouri - Columbia Research Reactor, Response to Request for Additional Information on License Renewal Amendment Request Project stage: Response to RAI ML16155A1322016-05-31031 May 2016 University of Missouri-Columbia Research Reactors Responses to the NRC Request for Additional Information, Dated October 28, 2015, Regarding Our Renewal Request for Amended Facility Operating License No. R-103 Project stage: Request ML16209A2362016-07-25025 July 2016 University of Missouri, Response to Request for Additional Information Regarding the Proposed Technical Specifications for the License Renewal Project stage: Response to RAI ML16209A2352016-07-25025 July 2016 University of Missouri - Columbia Research Reactor, Response to Request for Additional Information Regarding License Renewal Request Project stage: Response to RAI ML16216A1222016-08-24024 August 2016 University of Missouri at Columbia - Request for Additional Information Financial Information for Renewal of Facility Operating License No. R-103 for the University of Missouri at Columbia Research Reactor Project stage: RAI ML16246A0102016-08-31031 August 2016 University of Missouri - Columbia, Response to NRC Request for Additional Information Regarding Renewal for Amended Facility Operating License Project stage: Response to RAI ML16246A0082016-08-31031 August 2016 University of Missouri - Columbia, Submittal of Response to NRC Request for Additional Information Regarding Renewal for Amended Facility Operating License Project stage: Response to RAI ML16239A4252016-09-0707 September 2016 University of Missouri at Columbia - Request for Additional Information Regarding the Proposed Technical Specifications for the Renewal of Facility Operating License No. R-103 for the University of Missouri at Columbia Research Reactor Project stage: RAI ML16313A5172016-11-0707 November 2016 University If Missouri, Response to NRC Request for RAI, Dated September 7, 2016 Regarding License Renewal Amendment Project stage: Request ML16321A4852016-11-15015 November 2016 University of Missouri-Columbia Research Reactor - Response to Request for Additional Information Regarding License Renewal Request Project stage: Response to RAI 2015-12-02
[Table View] |
Text
March 23, 2016 Mr. Ralph Butler, Executive Director University of Missouri-Columbia Research Reactor Center 1513 Research Park Drive Columbia, MO 65211
SUBJECT:
UNIVERSITY OF MISSOURI AT COLUMBIACLARIFICATIONS NEEDED TO NUCLEAR REGULATORY COMMISSION STAFF REQUEST FOR ADDITIONAL INFORMATION REGARDING THE RENEWAL OF FACILITY OPERATING LICENSE NO. R-103 FOR THE UNIVERSITY OF MISSOURI AT COLUMBIA RESEARCH REACTOR (TAC NO. ME1580)
Dear Mr. Butler:
The U.S. Nuclear Regulatory Commission (NRC) is continuing its review of your application for the renewal of Facility Operating License No. R-103, dated August 31, 2006 (redacted versions of the application and supplement are available on the NRCs public web site at www.nrc.gov under Agencywide Documents Access and Management System (ADAMS) Accession Nos.:
ML062540114 - cover letter; ML092110573 - Safety Analysis Report (SAR), Chapters 1-9; ML092110597 - SAR, Chapters 10-18), for the University of Missouri at Columbia Research Reactor. The NRC staff reviewed your responses, by letter dated February 8, 2016 (ADAMS Accession No. ML16041A221), to our request for additional information (RAI), by letter dated April 17, 2015 (ADAMS Accession No. ML15098A648), and identified several RAI responses which needed additional information or clarification. These RAIs were discussed with your staff by a conference call conducted on March 15 and 17, 2016. Those RAI responses which need additional information or clarification are provided in the enclosure. We request that you provide responses within 14 days from the receipt of this letter.
In accordance with Title 10 of the Code of Federal Regulations (10 CFR) 50.30(b), Oath or affirmation, you must execute your response in a signed original document under oath or affirmation. Your response must be submitted in accordance with 10 CFR 50.4, Written communications. Information included in your response that is considered sensitive or proprietary, that you seek to have withheld from the public, must be marked in accordance with 10 CFR 2.390, Public inspections, exemptions, requests for withholding. Any information related to security should be submitted in accordance with 10 CFR 73.21, Protection of Safeguards Information: Performance Requirements. Following receipt of the additional information, we will continue our evaluation of your renewal request.
R. Butler If you need additional time to complete this request, or have any questions regarding this review, please contact me at (301) 415-0893, or by electronic mail at Geoffrey.Wertz@nrc.gov.
Sincerely,
/RA by Alexander Adams for/
Geoffrey A. Wertz, Project Manager Research and Test Reactors Licensing Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No. 50-186
Enclosure:
As stated cc: See next page
University of Missouri-Columbia Docket No. 50-186 cc:
Les Foyto, Associate Director Reactor and Facilities Operations University of Missouri - Columbia Research Reactor Center 1513 Research Park Drive Columbia, MO 65211 Homeland Security Coordinator Missouri Office of Homeland Security P.O. Box 749 Jefferson City, MO 65102 Planner, Department of Health and Senior Services Section for Environmental Public Health P.O. Box 570 Jefferson City, MO 65102 Deputy Director for Policy Department of Natural Resources 1101 Riverside Drive Fourth Floor East Jefferson City, MO 65101 A-95 Coordinator Division of Planning Office of Administration P.O. Box 809, State Capitol Building Jefferson City, MO 65101 Test, Research, and Training Reactor Newsletter University of Florida 202 Nuclear Sciences Center Gainesville, FL 32611
ML16083A025 *concurrence via email NRR-106
Enclosure OFFICE OF NUCLEAR REACTOR REGULATION CLARIFICATIONS NEEDED FOR THE REQUEST FOR ADDITIONAL INFORMATION FOR THE RENEWED LICENSE FOR THE UNIVERSITY OF MISSOURI-COLUMBIA RESEARCH REACTOR LICENSE NO. R-103; DOCKET NO. 50-186 The U.S. Nuclear Regulatory Commission (NRC) is continuing its review of your application for the renewal of Facility Operating License No. R-103, dated August 31, 2006, as supplemented, for the University of Missouri at Columbia Research Reactor (MURR). The NRC staff reviewed your responses, by letter dated February 8, 2016 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML16041A221), to our request for additional information (RAI), by letter dated April 17, 2015 (ADAMS Accession No. ML15098A648), and identified several RAI responses which needed additional information or clarification. These RAIs were discussed with your staff by a conference call conducted on March 15 and 17, 2016.
We request that you provide responses within 14 days from the receipt of this letter. The RAI responses which need additional information or clarification are provided below.
Note: The numbering in the column labeled RAI No. corresponds to the RAIs issued by NRC letter dated April 17, 2015. The brackets [page] at the end of each item indicate the page number on the RAI response provided by MURR letter dated February 8, 2016.
RAI No.
Information/Clarification Needed 3.c.
Provide control blade D total reactivity worth - measured and calculated in numerical form (not graphical) [page 9].
7.g.
Explain origin of source term data provided in RAI response [page 19].
Provide Attachment 4 in landscape mode to eliminate data wrapping around the next line, remove transport edits, and provide an explanation to translate calculated radioisotope inventories into the RAI response inventory.
Provide the equations (or spreadsheets) for calculations from Attachments 5 and 6.
7.g.iv Correct Kr-90 dose by eliminating the negative dose contribution from the curve fit [page 20].
Review/correct the gamma source terms.
Correct reference to Attachment 7 (not Attachment 5 as indicated).
Provide an updated Attachment 7.
9.b.ii.
Explain the source term for the 30 minutes decay [page 38].
Fuel Failure During Reactor Operation Analysis [page 22]
Explain the origin of core inventory of isotopes (which we now understand is not from Attachment 2) [page 24]
The mass transport equation is not clear, bracketing appears inconsistent - provide step-by-step description of the transport process with supporting equations for clarity [page 26].
Clarify how the current MURR TS 4.2.c containment building leakage rate is being used as the assumption for the leakage in the analysis [page 30].
The analysis uses an iodine reduction factor of 75 percent. The NRC staff noted (from Attachment 13) that MURR previously used an iodine reduction factor of 50 percent in accordance with the guidance in Regulatory Guide 1.3 in support of MURR License Amendment No. 8. The NRC staff needs additional information to understand the technical basis for use of an iodine reduction factor of 75 percent in the current fuel failure analyses [page 31].
The analysis indicates that there was no decay applied to the isotopes, but it appears that the decay of source isotopes was performed. Explain [page 32].
Derived Air Concentration values for Kr-89, Kr-90, Xe-137, and Xe-139 were divided by 300. Title 10 of the Code of Federal Regulations Part 20, Appendix B, uses a factor of 219, which the NRC staff will also use. Consider revision using a factor of 219 [page 35].
Fuel Handling Accident Analysis [page 39]
Origin of core inventory not clear (similar to comment on page 24 above)
[page 40].
The bracketing in several equations appears inconsistent (similar to comment on page 26 above, and again on page 47) [page 41].
Units used are non-standard (micro-Curies per cubic foot versus micro-Curies per cubic milliliter, similar comment on pages 47 and 48). Verify units [page 41].
The value of 229,801 cubic feet was used versus the Technical Specification value of 225,000 cubic feet (similar comment on pages 47 and 63). Explain [page 41].
Fueled Experiment Failure [page 56]
Several equations do not appear to have been bracketed correctly. Explain.
Units used are non-standard (micro-Curies per cubic foot versus micro-Curies per cubic milliliter, similar comment on pages 47 and 48). Verify.