Letter Sequence Approval |
---|
|
|
MONTHYEARML13364A2532014-01-0808 January 2014 Request for Additional Information for License Amendment Request 11-04, Changes to Technical Specifications for New Fuel Vault Project stage: RAI ML14078A6242014-04-18018 April 2014 Request for Withholding Information from Public Disclosure Regarding License Amendment Request 11-04, Changes to Technical Specifications for New Fuel Vault Project stage: Withholding Request Acceptance ML15118A6322015-05-18018 May 2015 Issuance of Amendment Regarding License Amendment Request Regarding New Fuel Valut Project stage: Approval 2014-04-18
[Table View] |
|
---|
Category:Letter
MONTHYEARIR 05000443/20240032024-10-30030 October 2024 Integrated Inspection Report 05000443/2024003 L-2024-176, Annual 10 CFR 140.21 Licensee Guarantees of Payment of Deferred Premiums2024-10-30030 October 2024 Annual 10 CFR 140.21 Licensee Guarantees of Payment of Deferred Premiums ML24303A0352024-10-29029 October 2024 Operator Licensing Examination Approval IR 05000443/20244022024-10-17017 October 2024 Material Control and Accounting Program Inspection Report 05000443/2024402 (Cover Letter Only) L-2024-159, Core Operating Limits Report for Reload Cycle 242024-10-15015 October 2024 Core Operating Limits Report for Reload Cycle 24 L-2024-169, Supplement to License Amendment Request to Adopt Common Emergency Plan with Site- Specific Annexes2024-10-15015 October 2024 Supplement to License Amendment Request to Adopt Common Emergency Plan with Site- Specific Annexes ML24254A2552024-09-25025 September 2024 Alternative Request No. 4A-01 for the Fourth 10-Year Inservice Inspection Interval L-2024-158, Supplemental Information to License Amendment Request to Adopt Common Emergency Plan with Site-Specific Annexes2024-09-25025 September 2024 Supplemental Information to License Amendment Request to Adopt Common Emergency Plan with Site-Specific Annexes ML24239A5382024-09-20020 September 2024 Issuance of Amendment No. 175 One-Time Allowable Outage Time Extension to the Technical Specification 3.8.1.1, A.C. Sources – Operating, Limiting Condition for Operation L-2024-136, Supplement to License Amendment Request to Adopt Common Emergency Plan with Site-Specific Annexes2024-09-16016 September 2024 Supplement to License Amendment Request to Adopt Common Emergency Plan with Site-Specific Annexes IR 05000443/20240052024-08-29029 August 2024 Updated Inspection Plan for Seabrook Station (Report 05000443/2024005) ML24232A1142024-08-21021 August 2024 Correction to Amendment No. 174 to Update the Period of Applicability (Poa) for the Pressure-Temperature Limits (PTL) and Low Temperature Overpressure Protection (LTOP) Curves L-2024-141, Third Supplement to NextEra Energy Seabrook, LLC, Letter L-2024-108, Response to Request for Additional Information (RAI) Regarding One Time Extension to Technical Specification 3.8.1.1.a, Allowed Outage Time with One Independent Circuit2024-08-15015 August 2024 Third Supplement to NextEra Energy Seabrook, LLC, Letter L-2024-108, Response to Request for Additional Information (RAI) Regarding One Time Extension to Technical Specification 3.8.1.1.a, Allowed Outage Time with One Independent Circuit Be L-2024-137, Second Supplement to NextEra Energy Seabrook, LLC, Letter L-2024-108, Response to Request for Additional Information (RAI) Regarding One Time Extension to Technical Specification 3.8.1.1.a, Allowed Outage Time with One Independent .2024-08-12012 August 2024 Second Supplement to NextEra Energy Seabrook, LLC, Letter L-2024-108, Response to Request for Additional Information (RAI) Regarding One Time Extension to Technical Specification 3.8.1.1.a, Allowed Outage Time with One Independent . IR 05000443/20240022024-08-0606 August 2024 Integrated Inspection Report 05000443/2024002 and Independent Spent Fuel Storage Installation Inspection Report 07200063/2024001 L-2024-127, Supplement to Letter L-2024-108, Response to Request for Additional Information (RAI) Regarding One Time Extension to Technical Specification 3.8.1.1.a, Allowed Outage Time with One Independent2024-08-0505 August 2024 Supplement to Letter L-2024-108, Response to Request for Additional Information (RAI) Regarding One Time Extension to Technical Specification 3.8.1.1.a, Allowed Outage Time with One Independent ML24163A0012024-08-0505 August 2024 LTR-24-0119-1-1 Response to Nh Letter Regarding Review of NextEras Emergency Preparedness Amendment Review L-2024-125, Notice of Intent to Provide Supplemental Information to License Amendment Request to Adopt Common Emergency Plan with Site-Specific Annexes2024-07-24024 July 2024 Notice of Intent to Provide Supplemental Information to License Amendment Request to Adopt Common Emergency Plan with Site-Specific Annexes L-2024-108, Response to Request for Additional Information (RAI) Regarding One Time Extension to Technical Specification 3.8.1.1.a, Allowed Outage Time with One Independent Circuit Between the Offsite.2024-07-16016 July 2024 Response to Request for Additional Information (RAI) Regarding One Time Extension to Technical Specification 3.8.1.1.a, Allowed Outage Time with One Independent Circuit Between the Offsite. ML24193A2432024-07-12012 July 2024 – Interim Audit Summary Report in Support of Review of License Amendment Requests Regarding Fleet Emergency Plan L-2024-114, Quality Assurance Topical Report (FPL-1 Revision 31 Annual Submittal2024-07-10010 July 2024 Quality Assurance Topical Report (FPL-1 Revision 31 Annual Submittal L-2024-102, Official Service List Update2024-06-19019 June 2024 Official Service List Update ML24149A2862024-06-12012 June 2024 NextEra Fleet - Proposed Alternative Frr 23-01 to Use ASME Code Case N-752-1, Risk-Informed Categorization and Treatment for Repair/Replacement Activities in Class 2 and 3 Systems Section X1, Division 1 (EPID L-2023-LLR-0009) - Letter L-2024-098, Preparation and Scheduling of Operator Licensing Examinations2024-06-12012 June 2024 Preparation and Scheduling of Operator Licensing Examinations L-2024-084, Relief Request 4A-01, Rev 1 - Revision to Relief Request for Examination of Control Rod Drive Mechanism (Rod) Housing H-4 Canopy Seal Weld2024-05-30030 May 2024 Relief Request 4A-01, Rev 1 - Revision to Relief Request for Examination of Control Rod Drive Mechanism (Rod) Housing H-4 Canopy Seal Weld IR 05000443/20240102024-05-29029 May 2024 Biennial Problem Identification and Resolution Inspection Report 05000443/2024010 IR 05000443/20240112024-05-24024 May 2024 Age-Related Degradation Inspection Report 05000443/2024011 IR 05000443/20240012024-05-13013 May 2024 Integrated Inspection Report 05000443/2024001 L-2024-061, NextEra Energy Seabrook, LLC, License Amendment Request - One Time Extension to Technical Specification 3.8.1.1.a, Allowed Outage Time with One Independent Circuit Between the Offsite Transmission Network and the Onsite Class 1E Distribut2024-05-10010 May 2024 NextEra Energy Seabrook, LLC, License Amendment Request - One Time Extension to Technical Specification 3.8.1.1.a, Allowed Outage Time with One Independent Circuit Between the Offsite Transmission Network and the Onsite Class 1E Distributio ML24046A0512024-05-0707 May 2024 Issuance of Amendment No. 174 to Update the Period of Applicability (Poa) for the Pressure-Temperature Limits (PTL) and Low Temperature Overpressure Protection (LTOP) Curves ML24127A0632024-05-0606 May 2024 Supplemental Information to License Amendment Request to Adopt Common Emergency Plan with Site-Specific Annexes L-2024-078, 2023 Annual Radioactive Effluent Release Report2024-05-0101 May 2024 2023 Annual Radioactive Effluent Release Report L-2024-077, 2023 Annual Radiological Environmental Operating Report2024-04-30030 April 2024 2023 Annual Radiological Environmental Operating Report IR 05000443/20245012024-04-22022 April 2024 Emergency Preparedness Biennial Exercise Inspection Report 05000443/2024501 05000443/LER-2024-001, Condition Prohibited by Technical Specifications - Transformer Bushing Failure - Offsite AC Sources2024-04-19019 April 2024 Condition Prohibited by Technical Specifications - Transformer Bushing Failure - Offsite AC Sources SBK-L-24030, 2023 Annual Environmental Operating Report2024-04-12012 April 2024 2023 Annual Environmental Operating Report L-2024-011, And Point Beach, Units 1 and 2 - 10 CFR 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications2024-03-13013 March 2024 And Point Beach, Units 1 and 2 - 10 CFR 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications L-2024-038, To Seabrook Emergency License Amendment Request - One Time Extension to Technical Specifications (TS) 3/4.8.1 Action a.3 Allowed Outage Time for an Inoperable Offsite Source2024-03-0808 March 2024 To Seabrook Emergency License Amendment Request - One Time Extension to Technical Specifications (TS) 3/4.8.1 Action a.3 Allowed Outage Time for an Inoperable Offsite Source ML24067A2622024-03-0808 March 2024 Issuance of Amendment No. 173 Revise Technical Specification 3/4.8.1 to Allow Replacement of Reserve Auxiliary Transformer (Emergency Circumstances) L-2024-037, To Seabrook Emergency License Amendment Request - One Time Extension to Technical Specifications (TS) 3/4.8.1 Action a.3 Allowed Outage Time for an Inoperable Offsite Source2024-03-0606 March 2024 To Seabrook Emergency License Amendment Request - One Time Extension to Technical Specifications (TS) 3/4.8.1 Action a.3 Allowed Outage Time for an Inoperable Offsite Source ML24065A2522024-03-0505 March 2024 Notice of Enforcement Discretion for Seabrook Station, Unit No. 1 (EPID: L-2024-033) L-2024-035, Supplement to Seabrook Emergency License Amendment Request - One Time Extension to Technical Specifications (TS) 3/4.8.1 Action a.3 Allowed Outage Time for an Inoperable Offsite Source2024-03-0505 March 2024 Supplement to Seabrook Emergency License Amendment Request - One Time Extension to Technical Specifications (TS) 3/4.8.1 Action a.3 Allowed Outage Time for an Inoperable Offsite Source L-2024-033, Request for Enforcement Discretion - Technical Specification (TS) 3/4.8.1.1 Ac. Sources Required Action Completion Time to Replace ED-X-3-B2024-03-0404 March 2024 Request for Enforcement Discretion - Technical Specification (TS) 3/4.8.1.1 Ac. Sources Required Action Completion Time to Replace ED-X-3-B L-2024-032, Emergency License Amendment Request- One Time Extension to Technical Specifications (TS) 3/4.8.1 Action a.3 Allowed Outage Time for an Inoperable Offsite Source2024-03-0404 March 2024 Emergency License Amendment Request- One Time Extension to Technical Specifications (TS) 3/4.8.1 Action a.3 Allowed Outage Time for an Inoperable Offsite Source IR 05000443/20230062024-02-28028 February 2024 Annual Assessment Letter for Seabrook Station (Report 05000443/2023006) L-2024-019, Relief Request 4A-01- Request for an Alternative to the Requirements of the ASME Code for Examination of Control Rod Drive Mechanism (Rod) Housing H-4 Canopy Seal Weld2024-02-28028 February 2024 Relief Request 4A-01- Request for an Alternative to the Requirements of the ASME Code for Examination of Control Rod Drive Mechanism (Rod) Housing H-4 Canopy Seal Weld L-2024-016, Radiological Emergency Plan (Ssrep), Revision 822024-02-13013 February 2024 Radiological Emergency Plan (Ssrep), Revision 82 IR 05000443/20230042024-02-12012 February 2024 Integrated Inspection Report 05000443/2023004 ML24009A1152024-01-29029 January 2024 – Exemption from Select Requirements of 10 CFR Part 73 (EPID L 2023 LLE-0043 (Security Notifications, Reports, and Recordkeeping and Suspicious Activity Reporting)) L-2024-010, Point Units 3 and 4, Seabrook, Duane Arnold, and Point Beach Units 1 and 2, Nuclear Property Insurance - 10 CFR 50.54(w)(3)2024-01-25025 January 2024 Point Units 3 and 4, Seabrook, Duane Arnold, and Point Beach Units 1 and 2, Nuclear Property Insurance - 10 CFR 50.54(w)(3) 2024-09-25
[Table view] Category:License-Operating (New/Renewal/Amendments) DKT 50
MONTHYEARML24239A5382024-09-20020 September 2024 Issuance of Amendment No. 175 One-Time Allowable Outage Time Extension to the Technical Specification 3.8.1.1, A.C. Sources – Operating, Limiting Condition for Operation ML24046A0512024-05-0707 May 2024 Issuance of Amendment No. 174 to Update the Period of Applicability (Poa) for the Pressure-Temperature Limits (PTL) and Low Temperature Overpressure Protection (LTOP) Curves ML24067A2622024-03-0808 March 2024 Issuance of Amendment No. 173 Revise Technical Specification 3/4.8.1 to Allow Replacement of Reserve Auxiliary Transformer (Emergency Circumstances) ML23312A1822023-12-22022 December 2023 Issuance of Amendment No. 172 Revision to Cooling Tower Service Water Loop or Cell Requirements ML22287A1572022-12-0505 December 2022 Issuance of Amendment No. 171 Revision to Technical Specifications to Adopt TSTF-577, Revised Frequencies for Steam Generator Tube Inspections ML22230C9242022-09-30030 September 2022 Issuance of Amendment No. 170 Revision of 120-Volt AC Vital Instrument Panel Requirements ML21008A0142021-02-25025 February 2021 Issuance of Amendment No. 168 Revise Technical Specification Table 3.3.4 to Change Time Delay Setpoints for Degraded Voltage Relays ML20293A1572020-12-28028 December 2020 Issuance of Amendment No. 167 Reactor Trip System Instrumentation Technical Specification Changes to Implement WCAP-14333 and WCAP-15376 ML20298A2532020-11-24024 November 2020 Issuance of Amendment No. 166 Revise Technical Specification 3/4.8.1, A.C. Sources Operating ML20318A0032020-11-24024 November 2020 Issuance of Revised Page for Renewed Facility Operating License Atomic Safety and Licensing Board Decisions LBP-20-09 and LBP-20-12 ML20070Q0712020-03-27027 March 2020 Issuance of Amendment No. 165 Emergency Core Cooling System Accumulator Technical Specification Changes ML19357A1952020-02-10010 February 2020 Unit No.1; & Turkey Point Nuclear Generating Unit Nos. 3 & 4 - Issuance of Amendments Nos. 265, 268, 164, 290, and 284 Revise Technical Specifications to Adopt TSTF-563 ML19326C4802019-12-0505 December 2019 Issuance of Amendment No. 163 One-Time Change to the Onsite Power Distribution Requirements ML19224A5632019-11-18018 November 2019 Issuance of Amendment No. 162 Revisions to Technical Specifications Associated with Movable Control Rods ML19148A7442019-07-31031 July 2019 Issuance of Amendment Nos. 161, 249, 200, 287, and 281 to Add Technical Specification Limiting Condition for Operation 3.0.6 ML19129A2432019-05-10010 May 2019 Correction to Amendment No. 160 Regarding Measurement and Assessment Frequency for Technical Specification 6.7.6 L, Control Room Envelope Habitability Program ML19065A2152019-03-29029 March 2019 Issuance of Amendment No. 160 Measurement and Assessment Frequency for Technical Specification 6.7.6.l, Control Room Envelope Habitability Program ML18355A4912019-03-12012 March 2019 Renewed Facility Operating License ML18204A2912019-03-11011 March 2019 Issuance of Amendment No. 159 Methodology for Analysis of Seismic Category I Structures with Concrete Affected by Alkali-Silica Reaction ML18247A5382018-11-27027 November 2018 Issuance of Amendment No. 158 Removing Requirement to Perform Certain Surveillance Requirements During Shutdown and Changes to Administrative Technical Specifications ML18199A6092018-08-0707 August 2018 Issuance of Amendment No. 157 Changes to the Technical Specifications Requirements for DC Batteries (CAC No. MG0046; EPID L-2017-LLA-0289) ML17102A8892017-04-13013 April 2017 Issuance of Amendment Licensing Basis Change for Service Water Cooling Tower ML17027A0782017-04-0707 April 2017 Issuance of Amendments Regarding Technical Specifications for Inservice Testing Programs (CAC Nos. MF8202 Through MF8209) SBK-L-16082, Supplement to License Amendment Request 16-01 Request to Extend Containment Leakage Test Frequency2016-05-31031 May 2016 Supplement to License Amendment Request 16-01 Request to Extend Containment Leakage Test Frequency ML16068A1302016-02-27027 February 2016 License Amendment Request 15-02, Adoption of Emergency Action Level Schemes Pursuant to NEI 99-01, Revision 6 Development of Emergency Action Levels for Non-Passive Reactors ML15096A2552015-11-0202 November 2015 Issuance of Amendment Regarding License Amendment Request 14-04, Revised Reactor Coolant System Pressure-Temperature Limits Applicable for 44 Effective Full Power Years ML15231A1442015-10-0606 October 2015 Issuance of Amendment No. 150 Regarding Note for Reactor Coolant System Surveillance Requirements ML15096A1312015-07-17017 July 2015 Issuance of Amendment Regarding Changes to Technical Specification 3.3.3.1, Radiation Monitoring for Plant Operations ML15118A6322015-05-18018 May 2015 Issuance of Amendment Regarding License Amendment Request Regarding New Fuel Valut ML15082A2332015-04-24024 April 2015 Issuance of Amendment Regarding Increase Voltage Limit for Diesel Generator Load Rejection Surveillance Requirement ML15058A7062015-04-22022 April 2015 Issuance of Amendment No. 146 Regarding the Cyber Security Plan Implementation Schedule ML15002A2512015-03-31031 March 2015 Unit No.1 - Issuance of Amendment Regarding License Amendment Request 14-06, Application Regarding the Removal of the Cold Leg Injection Permissive from Technical Specifications ML14345A2882015-02-0606 February 2015 Issuance of Amendment Regarding Technical Specifications Task Force Traveler-523, Generic Letter 2008-01, Managing Gas Accumulation Using the Consolidated Line Item Improvement Process ML14363A2752015-02-0404 February 2015 Non-Proprietary SE for Issuance of Amendment Regarding License Amendment Request Regarding Fixed Incore Detector System Analysis ML14184A7952014-09-0303 September 2014 Issuance of Amendment Regarding License Amendment Request Regarding Fuel Storage Changes ML13212A0692014-07-24024 July 2014 Issuance of Amendment Regarding the Risk-Informed Justifications for the Relocation of Specific Surveillance Frequency Requirements to a Licensee Controlled Program ML14029A4452014-03-0606 March 2014 Issuance of Amendment Regarding License Amendment Request 12-04, Application Regarding Cold Leg Injection Permissive ML13213A1432014-03-0505 March 2014 Issuance of Amendment Regarding the Use of Optimized Zirlo Fuel Rod Cladding Material ML13107A0162013-10-25025 October 2013 Issuance of Amendment Regarding the License Amendment Request 13-02, Application to Revise Technical Specifications to Adopt TSTSF-510, Revision to Steam Generator Program Inspection Frequencies and Tube Sample Selection.. ML13204A3792013-07-26026 July 2013 Correction to Issuance of Amendment 137 Regarding the Administrative Changes and Corrections to the Technical Specifications ML13074A7602013-06-17017 June 2013 Issuance of Amendment Regarding the Administrative Changes and Corrections to the Technical Specifications ML13114A3172013-04-25025 April 2013 Correction to Issuance of Amendment 136 Addition of Action Statement to Limiting Condition for Operation 3.6.5.1, Containment Enclosure Emergency Air Cleanup System ML1130000632013-04-23023 April 2013 Issuance of Amendment Addition of Action Statement to Limiting Condition for Operation 3.6.5.1, Containment Enclosure Emergency Air Cleanup System ML1208205102013-04-15015 April 2013 Issuance of Amendment Revision to the Applicability of the Reactor Coolant System Pressure-Temperature Limits and the Cold Overpressure Protection Setpoints ML13028A1462013-04-0404 April 2013 Issuance of Amendment Regarding the Extension of the Inspection Interval for the Reactor Coolant Pump Flywheels Using the Consolidated Line Item Improvement Process ML12332A3012013-01-31031 January 2013 Issuance of Amendment Emergency Plan ML12237A0942012-11-0202 November 2012 Issuance of Amendment Cyber Security Program ML12178A5372012-09-10010 September 2012 Issuance of Amendment Permanent Application of Steam Generator Tube Alternate Repair Criteria, H* ML1200302712012-02-23023 February 2012 Issuance of Amendment Regarding the Application to Revise the Technical Specifications for Reactor Coolant System Leakage Detection Instrumentation ML1120700482011-08-23023 August 2011 Issuance of Amendment Approval of Cyber Security Plan 2024-09-20
[Table view] Category:Safety Evaluation
MONTHYEARML24254A2552024-09-25025 September 2024 Alternative Request No. 4A-01 for the Fourth 10-Year Inservice Inspection Interval ML24239A5382024-09-20020 September 2024 Issuance of Amendment No. 175 One-Time Allowable Outage Time Extension to the Technical Specification 3.8.1.1, A.C. Sources – Operating, Limiting Condition for Operation ML24149A2862024-06-12012 June 2024 NextEra Fleet - Proposed Alternative Frr 23-01 to Use ASME Code Case N-752-1, Risk-Informed Categorization and Treatment for Repair/Replacement Activities in Class 2 and 3 Systems Section X1, Division 1 (EPID L-2023-LLR-0009) - Letter ML24046A0512024-05-0707 May 2024 Issuance of Amendment No. 174 to Update the Period of Applicability (Poa) for the Pressure-Temperature Limits (PTL) and Low Temperature Overpressure Protection (LTOP) Curves ML24067A2622024-03-0808 March 2024 Issuance of Amendment No. 173 Revise Technical Specification 3/4.8.1 to Allow Replacement of Reserve Auxiliary Transformer (Emergency Circumstances) ML23312A1822023-12-22022 December 2023 Issuance of Amendment No. 172 Revision to Cooling Tower Service Water Loop or Cell Requirements ML23073A1562023-03-23023 March 2023 Relief Request 4RA-22-01, Relief from the Requirements of the ASME Code ML22287A1572022-12-0505 December 2022 Issuance of Amendment No. 171 Revision to Technical Specifications to Adopt TSTF-577, Revised Frequencies for Steam Generator Tube Inspections ML22262A3142022-10-0404 October 2022 Relief Requests 3IR-18 and 3IR-19, Relief from the Requirements of the ASME Code ML22230C9242022-09-30030 September 2022 Issuance of Amendment No. 170 Revision of 120-Volt AC Vital Instrument Panel Requirements ML21008A0142021-02-25025 February 2021 Issuance of Amendment No. 168 Revise Technical Specification Table 3.3.4 to Change Time Delay Setpoints for Degraded Voltage Relays ML20293A1572020-12-28028 December 2020 Issuance of Amendment No. 167 Reactor Trip System Instrumentation Technical Specification Changes to Implement WCAP-14333 and WCAP-15376 ML20298A2532020-11-24024 November 2020 Issuance of Amendment No. 166 Revise Technical Specification 3/4.8.1, A.C. Sources Operating ML20070Q0712020-03-27027 March 2020 Issuance of Amendment No. 165 Emergency Core Cooling System Accumulator Technical Specification Changes ML20073E4342020-03-17017 March 2020 Relief from the Requirements of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code ML20076D2812020-03-17017 March 2020 Relief from the Requirements of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code ML19357A1952020-02-10010 February 2020 Unit No.1; & Turkey Point Nuclear Generating Unit Nos. 3 & 4 - Issuance of Amendments Nos. 265, 268, 164, 290, and 284 Revise Technical Specifications to Adopt TSTF-563 ML20015A1232020-02-0606 February 2020 Proposed Alternative to Use Encoded Phased Array Ultrasonic Examination Techniques ML19340A1282019-12-13013 December 2019 Relief from the Requirements of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code ML19326C4802019-12-0505 December 2019 Issuance of Amendment No. 163 One-Time Change to the Onsite Power Distribution Requirements ML19224A5632019-11-18018 November 2019 Issuance of Amendment No. 162 Revisions to Technical Specifications Associated with Movable Control Rods ML19249B1012019-09-30030 September 2019 Relief from the Requirements of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code; Relief Request RA-19-001 ML19148A7442019-07-31031 July 2019 Issuance of Amendment Nos. 161, 249, 200, 287, and 281 to Add Technical Specification Limiting Condition for Operation 3.0.6 ML19065A2152019-03-29029 March 2019 Issuance of Amendment No. 160 Measurement and Assessment Frequency for Technical Specification 6.7.6.l, Control Room Envelope Habitability Program ML18204A2912019-03-11011 March 2019 Issuance of Amendment No. 159 Methodology for Analysis of Seismic Category I Structures with Concrete Affected by Alkali-Silica Reaction ML18247A5382018-11-27027 November 2018 Issuance of Amendment No. 158 Removing Requirement to Perform Certain Surveillance Requirements During Shutdown and Changes to Administrative Technical Specifications ML18199A6092018-08-0707 August 2018 Issuance of Amendment No. 157 Changes to the Technical Specifications Requirements for DC Batteries (CAC No. MG0046; EPID L-2017-LLA-0289) ML18106B1212018-04-25025 April 2018 Proposed Alternative to Use Encoded Phased Array Ultrasonic Examination Techniques ML17102A8892017-04-13013 April 2017 Issuance of Amendment Licensing Basis Change for Service Water Cooling Tower ML17027A0782017-04-0707 April 2017 Issuance of Amendments Regarding Technical Specifications for Inservice Testing Programs (CAC Nos. MF8202 Through MF8209) ML17080A0382017-03-27027 March 2017 Relief from the Requirements of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code ML17046A4432017-03-15015 March 2017 Issuance of Amendment Extension of Containment Leakage Rate Test Frequency ML16330A1182016-12-15015 December 2016 NextEra Fleet - Safety Evaluation for Proposed Alternative to the American Society of Mechanical Engineers Operation and Maintenance Code by Adoption of Approved Code Case OMN-20, Inservice Test Frequency (CAC Nos. MF8195 Through MF8201) ML16321A4182016-12-0101 December 2016 Safety Evaluation Regarding Implementation of Mitigating Strategies and Reliable Spent Fuel Pool Instrumentation Related to Orders EA-12-049 and EA-12-051 (CAC Nos. MF0836 and MF0837) ML15096A2552015-11-0202 November 2015 Issuance of Amendment Regarding License Amendment Request 14-04, Revised Reactor Coolant System Pressure-Temperature Limits Applicable for 44 Effective Full Power Years ML15231A1442015-10-0606 October 2015 Issuance of Amendment No. 150 Regarding Note for Reactor Coolant System Surveillance Requirements ML15205A3332015-07-28028 July 2015 Safety Evaluation by the Office of Nuclear Reactor Regulation Related to Request for Exemption from Table 1 of 10 CFR Part 50, Appendix G NextEra Energy Seabrook, LLC Seabrook Station, Unit 1 Docket No. 50-443 ML15096A1432015-07-28028 July 2015 Exemption from Specific Requirements of 10 CFR Part 50, Appendix G, and 10 CFR 50.60 ML15096A1312015-07-17017 July 2015 Issuance of Amendment Regarding Changes to Technical Specification 3.3.3.1, Radiation Monitoring for Plant Operations ML15118A6322015-05-18018 May 2015 Issuance of Amendment Regarding License Amendment Request Regarding New Fuel Valut ML15082A2332015-04-24024 April 2015 Issuance of Amendment Regarding Increase Voltage Limit for Diesel Generator Load Rejection Surveillance Requirement ML15058A7062015-04-22022 April 2015 Issuance of Amendment No. 146 Regarding the Cyber Security Plan Implementation Schedule ML15002A2512015-03-31031 March 2015 Unit No.1 - Issuance of Amendment Regarding License Amendment Request 14-06, Application Regarding the Removal of the Cold Leg Injection Permissive from Technical Specifications ML14345A2882015-02-0606 February 2015 Issuance of Amendment Regarding Technical Specifications Task Force Traveler-523, Generic Letter 2008-01, Managing Gas Accumulation Using the Consolidated Line Item Improvement Process ML14363A2752015-02-0404 February 2015 Non-Proprietary SE for Issuance of Amendment Regarding License Amendment Request Regarding Fixed Incore Detector System Analysis ML14184A7952014-09-0303 September 2014 Issuance of Amendment Regarding License Amendment Request Regarding Fuel Storage Changes ML13212A0692014-07-24024 July 2014 Issuance of Amendment Regarding the Risk-Informed Justifications for the Relocation of Specific Surveillance Frequency Requirements to a Licensee Controlled Program ML14071A4102014-04-10010 April 2014 Request for Relief RA-14-001 from American Society of Mechanical Engineers Boiler and Pressure Vessel Code, Section XI Requirements Regarding the Reactor Vessel Head Flange Seal Leak Detection Piping (TAC No. Mfxxxx) ML14029A4452014-03-0606 March 2014 Issuance of Amendment Regarding License Amendment Request 12-04, Application Regarding Cold Leg Injection Permissive ML13213A1432014-03-0505 March 2014 Issuance of Amendment Regarding the Use of Optimized Zirlo Fuel Rod Cladding Material 2024-09-25
[Table view] Category:Technical Specifications
MONTHYEARML24046A0512024-05-0707 May 2024 Issuance of Amendment No. 174 to Update the Period of Applicability (Poa) for the Pressure-Temperature Limits (PTL) and Low Temperature Overpressure Protection (LTOP) Curves ML24067A2622024-03-0808 March 2024 Issuance of Amendment No. 173 Revise Technical Specification 3/4.8.1 to Allow Replacement of Reserve Auxiliary Transformer (Emergency Circumstances) SBK-L-22024, Response to Request for Additional Information (Raj) Regarding License Amendment Request 21-01, Revise 120-Volt AC Vital Instrument Panel Requirements2022-03-0707 March 2022 Response to Request for Additional Information (Raj) Regarding License Amendment Request 21-01, Revise 120-Volt AC Vital Instrument Panel Requirements ML20293A1572020-12-28028 December 2020 Issuance of Amendment No. 167 Reactor Trip System Instrumentation Technical Specification Changes to Implement WCAP-14333 and WCAP-15376 ML19326C4802019-12-0505 December 2019 Issuance of Amendment No. 163 One-Time Change to the Onsite Power Distribution Requirements SBK-L-19104, License Amendment Request 19-02, One-Time Change to the Seabrook Technical Specifications Onsite Power Distribution Requirements2019-10-0303 October 2019 License Amendment Request 19-02, One-Time Change to the Seabrook Technical Specifications Onsite Power Distribution Requirements ML18228A7372018-08-31031 August 2018 Correction Letter for Amendment No. 157 Changes to the Technical Specifications Requirements for DC Batteries (CAC No. MG0046; EPID L-2017-LLA-0289) L-2018-049, Application to Add Limiting Condition for Operation (LCO) 3.0.6 to the Technical Specifications2018-05-29029 May 2018 Application to Add Limiting Condition for Operation (LCO) 3.0.6 to the Technical Specifications ML15096A2552015-11-0202 November 2015 Issuance of Amendment Regarding License Amendment Request 14-04, Revised Reactor Coolant System Pressure-Temperature Limits Applicable for 44 Effective Full Power Years ML15231A1442015-10-0606 October 2015 Issuance of Amendment No. 150 Regarding Note for Reactor Coolant System Surveillance Requirements SBK-L-15183, LER, Seabrook Station - Technical Specification Special Report Radiation Monitor Inoperable Greater than 7 Days2015-09-25025 September 2015 LER, Seabrook Station - Technical Specification Special Report Radiation Monitor Inoperable Greater than 7 Days ML15096A1312015-07-17017 July 2015 Issuance of Amendment Regarding Changes to Technical Specification 3.3.3.1, Radiation Monitoring for Plant Operations ML15118A6322015-05-18018 May 2015 Issuance of Amendment Regarding License Amendment Request Regarding New Fuel Valut ML15082A2332015-04-24024 April 2015 Issuance of Amendment Regarding Increase Voltage Limit for Diesel Generator Load Rejection Surveillance Requirement ML15058A7062015-04-22022 April 2015 Issuance of Amendment No. 146 Regarding the Cyber Security Plan Implementation Schedule ML14345A2882015-02-0606 February 2015 Issuance of Amendment Regarding Technical Specifications Task Force Traveler-523, Generic Letter 2008-01, Managing Gas Accumulation Using the Consolidated Line Item Improvement Process ML14363A2752015-02-0404 February 2015 Non-Proprietary SE for Issuance of Amendment Regarding License Amendment Request Regarding Fixed Incore Detector System Analysis ML14184A7952014-09-0303 September 2014 Issuance of Amendment Regarding License Amendment Request Regarding Fuel Storage Changes ML13212A0692014-07-24024 July 2014 Issuance of Amendment Regarding the Risk-Informed Justifications for the Relocation of Specific Surveillance Frequency Requirements to a Licensee Controlled Program ML14029A4452014-03-0606 March 2014 Issuance of Amendment Regarding License Amendment Request 12-04, Application Regarding Cold Leg Injection Permissive SBK-L-13121, License Amendment Request 13-05, Fixed Incore Detector System Analysis Methodology2013-09-10010 September 2013 License Amendment Request 13-05, Fixed Incore Detector System Analysis Methodology ML1130000632013-04-23023 April 2013 Issuance of Amendment Addition of Action Statement to Limiting Condition for Operation 3.6.5.1, Containment Enclosure Emergency Air Cleanup System SBK-L-13061, Response to December 2012 Request for Additional Information Regarding License Amendment Request 11-04, Changes to Technical Specifications for New and Spent Fuel Storage2013-03-27027 March 2013 Response to December 2012 Request for Additional Information Regarding License Amendment Request 11-04, Changes to Technical Specifications for New and Spent Fuel Storage SBK-L-13030, LAR 13-02 - Application to Revise Technical Specifications to Adopt TSTF-510, Revision to Steam Generator Program Inspection Frequencies and Tube Sample Selection, Using the Consolidated Line Item Improvement Process2013-03-27027 March 2013 LAR 13-02 - Application to Revise Technical Specifications to Adopt TSTF-510, Revision to Steam Generator Program Inspection Frequencies and Tube Sample Selection, Using the Consolidated Line Item Improvement Process SBK-L-12266, Supplement to License Amendment Request 10-02, Application for Change to the Technical Specifications for the Containment Enclosure Emergency Air Cleanup System2013-01-31031 January 2013 Supplement to License Amendment Request 10-02, Application for Change to the Technical Specifications for the Containment Enclosure Emergency Air Cleanup System SBK-L-12235, License Amendment Request 12-06, Application for Technical Specification Improvement to Extend the Inspection Interval for Reactor Coolant Pump Flywheels Using the Consolidated Line Item Improvement Process2012-12-20020 December 2012 License Amendment Request 12-06, Application for Technical Specification Improvement to Extend the Inspection Interval for Reactor Coolant Pump Flywheels Using the Consolidated Line Item Improvement Process SBK-L-11130, License Amendment Request 11-03, Regarding Containment Spray Nozzles Surveillance Requirement2011-07-14014 July 2011 License Amendment Request 11-03, Regarding Containment Spray Nozzles Surveillance Requirement SBK-L-09196, License Amendment Request to Revise Technical Specification (TS) Sections 6.7.6.k, Steam Generator (SG) Program and TS 6.8.1.7, Steam Generator Tube Inspection Report for One-Time Alternate Repair Criteria2009-09-18018 September 2009 License Amendment Request to Revise Technical Specification (TS) Sections 6.7.6.k, Steam Generator (SG) Program and TS 6.8.1.7, Steam Generator Tube Inspection Report for One-Time Alternate Repair Criteria ML0819102622008-07-30030 July 2008 Technical Specifications, Issuance of Amendment Nuclear Instrumentation Surveillance Requirements ML0812000612008-04-29029 April 2008 Tec Specs to Amendment 118, License No. NPF-086, for Seabrook, Unit 1 ML0804606942008-03-27027 March 2008 Tech Spec Pages for Amendment 117 Setpoint Change for Reactor Trip System Interlock P-9 SBK-L-07142, Correction to License Amendment Request (LAR) 07-02, Application to Revise the Technical Specifications Regarding Control Room Habitability in Accordance with TSTF-448, Revision 3, Using the Consolidated Line Item Improvement Process2007-10-15015 October 2007 Correction to License Amendment Request (LAR) 07-02, Application to Revise the Technical Specifications Regarding Control Room Habitability in Accordance with TSTF-448, Revision 3, Using the Consolidated Line Item Improvement Process ML0723901902007-08-23023 August 2007 Tech Spec Pages for Amendment 116 Technical Specification Task Force (TSTF)-449, Steam Generator Tube Integrity. SBK-L-07112, License Amendment Request 07-02, Application to Revise the Technical Specifications Regarding Control Room Habitability in Accordance with TSTF-448, Revision 3, Using the Consolidated Line Item Improvement Process.2007-07-17017 July 2007 License Amendment Request 07-02, Application to Revise the Technical Specifications Regarding Control Room Habitability in Accordance with TSTF-448, Revision 3, Using the Consolidated Line Item Improvement Process. ML0708802862007-03-28028 March 2007 Technical Specifications, Issuance of Amendment Regarding TSTF -449 Steam Generator Tube Integrity TAC No. MD0696 ML0704704742007-02-0909 February 2007 Technical Specifications, Issuance of Amendment Mode Change Limitations ML0629902612006-10-17017 October 2006 Tech Spec Pages for Amendment 113 Removal of License Condition 2.G ML0627501812006-09-29029 September 2006 Technical Specifications, Limited Inspection of the Steam Generator Tube Portion within the Tubesheet SBK-L-06157, Response to Request for Additional Information Regarding License Amendment Request 05-08 Limited Inspection of the Steam Generator Tube Portion within the Tubesheet.2006-08-0808 August 2006 Response to Request for Additional Information Regarding License Amendment Request 05-08 Limited Inspection of the Steam Generator Tube Portion within the Tubesheet. SBK-L-06059, License Amendment Request 06-03 Application for Amendment to Technical Specifications for Miscellaneous Changes.2006-08-0707 August 2006 License Amendment Request 06-03 Application for Amendment to Technical Specifications for Miscellaneous Changes. ML0616402492006-06-12012 June 2006 Technical Specification - Correction of Amendment No. 108, Six-Month Extension for the Containment Integrated Leakage Rate Test Interval ML0616402512006-06-0909 June 2006 Tech Spec Page for Emergency Amendment 111 Allowed Outage Time Extension from 7 Days to 14 Days for Enclosure Air Handling Fan SBK-L-06127, Emergency License Amendment Request 06-07, Containment Enclosure Emergency Air Cleanup System Allowed Outage Time One Time Change2006-06-0707 June 2006 Emergency License Amendment Request 06-07, Containment Enclosure Emergency Air Cleanup System Allowed Outage Time One Time Change ML0614402592006-05-22022 May 2006 Tech Spec Pages for Amendment 110 Regarding Measurement Uncertainty Recapture Power Uprate ML0612802822006-05-0505 May 2006 Technical Specification Pages Elimination of Monthly Operating Reports and Occupational Radiation Exposure Reports - Technical Specifications Index, 6.0 Administrative Controls SBK-L-06065, Application for Technical Specification Change Regarding Mode Change Limitations Using the Consolidated Line Item Improvement Process.2006-04-28028 April 2006 Application for Technical Specification Change Regarding Mode Change Limitations Using the Consolidated Line Item Improvement Process. ML0610203542006-04-13013 April 2006 Tech Spec Pages for Correction of Amendment No. 107, Regarding Removal of Requirement to Perform End-of-Life Moderator Temperature Coefficient Measurement (Tac No. MC6566) ML0608601162006-03-24024 March 2006 Technical Specification Page, Revises to Permit a one-time, 6-month, Addition to the currently-approved 5-year Extension to the 10-year Test Interval for the Containment Integrated Leak Rate Test L-2006-042, 30-day Response to NRC Generic Letter 2006-01, Steam Generator Tube Integrity and Associated Technical Specifications, January 20, 20062006-02-17017 February 2006 30-day Response to NRC Generic Letter 2006-01, Steam Generator Tube Integrity and Associated Technical Specifications, January 20, 2006 ML0600904762006-01-0606 January 2006 Tech Spec Page for Amendment 106 Extension of Containment Air Lock Interlock Surveillance Requirement Interval 2024-05-07
[Table view] |
Text
OFFICIAL USE ONLY PROPRIETARY INFORMATION UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 May 18, 2015 Mr. Dean Curtland, Site Vice President c/o Michael Ossing Seabrook Station NextEra Energy Seabrook, LLC P.O. Box 300 Seabrook, NH 03874
SUBJECT:
SEABROOK STATION, UNIT NO. 1 - ISSUANCE OF AMENDMENT REGARDING LICENSE AMENDMENT REQUEST REGARDING NEW FUEL VAULT (TAC NO. MF3283)
Dear Mr. Curtland:
The Commission has issued the enclosed Amendment No. 148 to Facility Operating License No. NPF-86 for the Seabrook Station, Unit No. 1. This amendment consists of changes to the facility technical specifications (TSs) in response to your application dated January 30, 2012, as supplemented by letters dated May 10, 2012, September 20, 2012, March 27, 2013, December 20, 2013, January 29, 2014, March 13, 2014, and February 25, 2015.
The original application proposed revisions to the TSs for new and spent fuel storage as a result of the new criticality analyses for the new fuel vault (NFV) and spent fuel pool (SFP). By letter dated December 20, 2013, NextEra requested that the SFP and NFV be separated into two separate license amendment requests. On September 3, 2014, the Commission approved Amendment No. 142 that revised the TSs related to spent fuel storage as a result of new criticality analyses for the SFP. The license amendment request for the NFV is being processed under TAC No. MF3283.
Enclosure 3 transmitted herewith contains sensitive unclassified information When separated from Enclosure 3, this document is decontrolled.
OFFICIAL USE ONLY PROPRIETARY INFORMATION
OFFICIAL USE ONLY PROPRIETARY INFORMATION D. Curtland A copy of our safety evaluation is also enclosed. Notice of Issuance will be included in the Commission's biweekly Federal Register notice.
. Lamb, Senior Project Manager Licensing Branch 1-2 1v ion of Operating Reactor Licensing ice of Nuclear Reactor Regulation Docket No. 50-443
Enclosures:
- 1. Amendment No. 148 to NPF-86
- 2. Non-Proprietary Safety Evaluation
- 3. Proprietary Safety Evaluation cc w/encls 1 & 2: Distribution via Listserv OFFICIAL USE ONLY PROPRIETARY INFORMATION
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 NEXTERA ENERGY SEABROOK, LLC, ET AL.*
DOCKET NO. 50-443 SEABROOK STATION, UNIT NO. 1 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 148 License No. NPF-86
- 1. The Nuclear Regulatory Commission (the Commission) has found that:
A. The application for amendment filed by NextEra Energy Seabrook, LLC, et al.,
(the licensee) dated January 30, 2012, as supplemented May 10, 2012, September 20, 2012, March 27, 2013, December 20, 2013, January 29, 2014, March 13, 2014, and February 25, 2015, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I; B. The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C. There is reasonable assurance: (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D. The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E. The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.
- NextEra Energy Seabrook, LLC is authorized to act as agent for the: Hudson Light & Power Department, Massachusetts Municipal Wholesale Electric Company, and Taunton Municipal Light Plant and has exclusive responsibility and control over the physical construction, operation and maintenance of the facility.
- 2. Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. NPF-86 is hereby amended to read as follows:
(2) Technical Specifications The Technical Specifications contained in Appendix A, as revised through Amendment No. 148, and the Environmental Protection Plan contained in Appendix B are incorporated into the Facility License No. NPF-86.
NextEra Energy Seabrook, LLC shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.
- 3. This license amendment is effective as of its date of issuance and shall be implemented within 60 days.
FOR THE NUCLEAR REGULATORY COMMISSION
~vi tvl.dr_r Douglas A. Broaddus, Chief Plant Licensing Branch 1-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation
Attachment:
Changes to the License and Technical Specifications Date of Issuance: May 18, 2015
ATTACHMENT TO LICENSE AMENDMENT NO. 148 FACILITY OPERATING LICENSE NO. NPF-86 DOCKET NO. 50-443 Replace the following page of Facility Operating License No. NPF-86 with the attached revised page. The revised page is identified by amendment number and contains a marginal line indicating the area of change.
Remove 3 3 Replace the following pages of Appendix A, Technical Specifications, with the attached revised pages as indicated. The revised pages are identified by amendment number and contain marginal lines indicating the area of change.
Remove 3/4 9-17 3/4 9-17 5-10 5-10
(4) NextEra Energy Seabrook, LLC, pursuant to the Act and 10 CFR 30, 40, and 70, to receive, possess, and use at any time any byproduct, source, and special nuclear material as sealed neutron sources for reactor startup, sealed sources for reactor instrumentation and radiation monitoring equipment calibration, and as fission detectors in amounts as required; (5) NextEra Energy Seabrook, LLC, pursuant to the Act and 10 CFR 30, 40, and 70, to receive, possess, and use in amounts as required any byproduct, source, or special nuclear material without restriction to chemical or physical form, for sample analysis or instrument calibration or associated with radioactive apparatus or components; (6) NextEra Energy Seabrook, LLC, pursuant to the Act and 10 CFR 30, 40, and 70, to possess, but not separate, such byproduct and special nuclear materials as may be produced by the operation of the facility authorized herein; and (7) DELETED C. This license shall be deemed to contain and is subject to the conditions specified in the Commission's regulations set forth in 10 CFR Chapter I and is subject to all applicable provisions of the Act and to the rules, regulations, and orders of the Commission now or hereafter in effect; is subject to the additional conditions specified or incorporated below:
(1) Maximum Power Level NextEra Energy Seabrook, LLC, is authorized to operate the facility at reactor core power levels not in excess of 3648 megawatts thermal (100% of rated power).
(2) Technical Specifications The Technical Specifications contained in Appendix A, as revised through Amendment No. 148*, and the Environmental Protection Plan contained in Appendix B are incorporated into the Facility License No. NPF-86. NextEra Energy Seabrook, LLC shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.
(3) License Transfer to FPL Energy Seabrook. LLC**
- a. On the closing date(s) of the transfer of any ownership interests in Seabrook Station covered by the Order approving the transfer, FPL Energy Seabrook, LLC**, shall obtain from each respective transferring owner all of the accumulated decommissioning trust funds for the facility, and ensure the deposit of such funds and additional funds, if necessary, into a decommissioning trust or trusts for Seabrook Station established by FPL Energy Seabrook, LLC**, such that the amount of such funds deposited meets or exceeds the amount required under 10 CFR 50. 75 with respect to the interest in Seabrook Station FPL Energy Seabrook, LLC**,
acquires on such dates(s).
- On April 16, 2009, the name "FPL Energy Seabrook, LLC" was changed to "NextEra Energy Seabrook, LLC".
AMENDMENT NO. 148
REFUELING OPERATIONS 3/4.9.14 (This Specification Number is not used)
SEABROOK - UNIT 1 3/4 9-17 Amendment No. 6, 142, 148
DESIGN FEATURES 5.6 FUEL STORAGE CRITICALITY 5.6.1.1 The spent fuel storage racks are designed and shall be maintained with:
- a. A kett less than 1.0 when flooded with unborated water, which includes an allowance for biases and uncertainties as described in UFSAR Chapter 9.
- b. A kett less than or equal to 0.95 when flooded with water borated to 500 ppm, which includes an allowance for biases and uncertainties as described in UFSAR Chapter 9.
- c. A nominal 10.35 inch center-to-center distance between fuel assemblies placed in the storage racks.
5.6.1.2 The new fuel storage racks are designed and shall be maintained with:
- a. A kett equivalent to less than or equal to 0.95 when fully flooded with unborated water, which includes an allowance for biases and uncertainties as described in UFSAR Chapter 9.
- b. A kett equivalent to less than or equal to 0.98 if moderated by aqueous foam, which includes an allowance for biases and uncertainties as described in UFSAR Chapter 9.
- c. At least a nominal 21 inch center-to-center distance between fuel assemblies placed in the storage racks with a nominal 33 inches center-to-center distance (east to west) between fuel assemblies in the center column and adjacent columns.
5.6.1.3 Fresh or irradiated fuel assemblies shall be stored in the spent fuel pool in compliance with the following:
- a. Any 2x2 array of Region 1 storage cells containing fuel shall comply with the storage pattern in Figure 5.6-1 and the requirements of Table 5.6-1. The reactivity ranks of fuel assemblies in the 2x2 array (rank determined using Table 5.6-1) shall be equal to or less than defined for the 2x2 array.
- b. Any 2x2 array of Region 2 storage cells containing fuel shall comply with the storage requirements defined in Figure 5.6-2 and the requirements of Table 5.6-1 or with the allowable exception of evaluated assemblies stored on the periphery of Region 2 as defined in 5.6.1.3.c. The evaluated assemblies are listed in Table 5.6-2.
SEABROOK - UNIT 1 5-10 Amendment No. 6, 142, 148
OFFICIAL USE ONLY PROPRIETARY INFORMATION UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 RELATED TO AMENDMENT NO. 148 TO FACILITY OPERATING LICENSE NO. NPF-86 NEXTERA ENERGY SEABROOK. LLC SEABROOK STATION. UNIT NO. 1 DOCKET NO. 50-443 Proprietary information pursuant to Title 1O of the Code of Federal Regulations (10 CFR), Section 2.390.
has been redacted from this document. Redacted information is identified by blank space enclosed within double brackets as shown here (( )).
OFFICIAL USE ONLY PROPRIETARY INFORMATION
OFFICIAL USE ONLY PROPRIETARY INFORMATION
1.0 INTRODUCTION
By application dated January 30, 2012 (Reference 1), as supplemented by letters dated May 10, 2012 (Reference 2), September 20, 2012 (Reference 3), March 27, 2013 (Reference 4), December 20, 2013 (Reference 5), January 29, 2014 (Reference 6), March 13, 2014 (Reference 7), and February 25, 2015 (Reference 8), NextEra Energy Seabrook, LLC (NextEra or the licensee) requested changes to the technical specifications (TSs) for Seabrook Station, Unit 1 (Seabrook).
The original application proposed revisions to the TSs for new and spent fuel storage as a result of the new criticality analyses for the new fuel vault (NFV) and spent fuel pool (SFP). By letter dated December 20, 2013, NextEra requested that the SFP and NFV be separated into two separate license amendment requests. This amendment revises the TSs related to NFV. On September 3, 2014, the U.S. Nuclear Regulatory Commission (NRC) issued Amendment No. 142 that revised the TSs related to spent fuel storage as a result of new criticality analyses for the SFP. During the review, a revised set of proposed TS were provided as Attachment 8 to Reference 4.
The supplements dated May 10, 2012, September 20, 2012, March 27, 2013, December 20, 2013, January 29, 2014, March 13, 2014, and February 25, 2015, provided additional information that clarified the application, did not expand the scope of the application as originally noticed, and did not change the staff's original proposed no significant hazards consideration determination as published in the Federal Register on August 14, 2012 (77 FR 48559).
HOLTEC report Hl-2114996 (Reference 9) presents the nuclear criticality safety (NCS) analysis for the requested Seabrook NFV and SFP changes. The report describes the methodology and analytical models used in the NCS analysis to show that the maximum k-effective (kett) for fuel stored in the NFV and SFP will meet the appropriate limits specified in Section 50.68 of Title 10 of the Code of Federal Regulations (10 CFR 50.68). The following evaluation presents the results of the NRC staff's review of the NCS analysis (Reference 10 provided as Attachment 2 to Reference 1 and revised by Reference 9 provided as Attachment 3 to Reference 4).
2.0 BACKGROUND
New fuel assemblies of the Westinghouse 17x17 Robust Fuel Assembly (RFA) design may be stored in what are normally dry conditions in the Seabrook NFV. The NFV NCS analysis has been updated to support modification of the NFV TS to permit storage of up to 90 fresh fuel assemblies with uranium dioxide fuel enrichments up to a maximum of 5 weight percent Uranium-235. The NFV array is a 5x18 arrangement of storage cells with most cells spaced with a 21 inch center-to-center cell pitch. Along the 5-row side, the spacing between cells in the second and third rows and between the third and fourth rows has a 33 inch center-to-center cell pitch. Each assembly is stored in a nominal 0.093 inch thick steel box. The current TS requires that every other storage location in the third row be left empty if fuel with enrichments of 3.675 weight percent Uranium-235 or higher is stored in the NFV. Elimination of this restriction is proposed in this license amendment request based on the re-analysis of the NFV.
OFFICIAL USE ONLY PROPRIETARY INFORMATION
OFFICIAL USE ONLY PROPRIETARY INFORMATION
3.0 REGULATORY EVALUATION
Title 10 of the Code of Federal Regulations (10 CFR), Part 50, Appendix A, Criterion 62 states:
Criticality in the fuel storage and handling system shall be prevented by physical systems or processes, preferably by use of geometrically safe configurations.
Paragraph 50.68(b)(1) of 10 CFR states:
Plant procedures shall prohibit the handling and storage at any one time of more fuel assemblies than have been determined to be safely subcritical under the most adverse moderation conditions feasible by unborated water.
Paragraph 50.68(b)(2) of 10 CFR states:
The estimated ratio of neutron production to neutron absorption and leakage (k-effective) of the fresh fuel in the fresh fuel storage racks shall be calculated assuming the racks are loaded with fuel of the maximum fuel assembly reactivity and flooded with unborated water and must not exceed 0.95, at a 95 percent probability, 95 percent confidence level. This evaluation need not be performed if administrative controls and/or design features prevent such flooding or if fresh fuel storage racks are not used.
Paragraph 50.68(b)(3) of 10 CFR states:
If optimum moderation of fresh fuel in the fresh fuel storage racks occurs when the racks are assumed to be loaded with fuel of the maximum fuel assembly reactivity and filled with low-density hydrogenous fluid, the k-effective corresponding to this optimum moderation must not exceed 0.98, at a 95 percent probability, 95 percent confidence level. This evaluation need not be performed if administrative controls and/or design features prevent such moderation or if fresh fuel storage racks are not used.
Paragraph 50.36(c)(4) of 10 CFR states:
Design features. Design features to be included are those features of the facility such as materials of construction and geometric arrangements, which, if altered or modified, would have a significant effect on safety and are not covered in categories described in paragraphs (c) (1 ), (2), and (3) of this section.
The Seabrook NFV NCS analysis demonstrates that, consistent with the requirements of 10 CFR 50.68.
OFFICIAL USE ONLY PROPRIETARY INFORMATION
OFFICIAL USE ONLY PROPRIETARY INFORMATION
4.0 TECHNICAL EVALUATION
4.1 Proposed Change There are several proposed TS changes, originally provided in Reference 1 and supplemented, that either impact the NCS analysis or implement changes in fuel storage requirements. These changes are related to revised criticality control requirements for both the NFV and the SFP, incorporation of the effects of BORALTM blistering in the Region 1 analysis, elimination of credit for Boraflex in the Region 2 analysis, and taking credit for the presence of soluble boron in the SFP. The technical evaluation detailed in this safety evaluation focuses only on the changes related to the NFV.
The proposed TS changes related to the NFV remove the restrictions currently in place when fuel with enrichments greater than or equal to 3.675 weight percent Uranium-235 is stored in the NFV.
The TS changes related to fuel storage in the NFV include:
- Elimination of Section 3/4.9.14, "NEW FUEL STORAGE"
- Revision of Section 5.6.1.2 to more accurately describe the spacing of fuel storage locations and to refer to USFAR Chapter 9 for NCS analysis details The proposed TS changes do not include any maximum enrichment limit, as was previously specified in Section 3/4.9.14. Furthermore, the revised analysis covers only the Westinghouse 17x17 RFA fuel assembly design.
4.2 Method of Review The review was performed consistent with Section 9.1.1 of NUREG-0800 and the guidance provided in Division of Safety System Interim Staff Guidance DSS-ISG-2010-01, "Staff Guidance Regarding the Nuclear Criticality Safety Analysis for Spent Fuel Pools" (Reference 11 ).
4.3 NFV NCS Analysis Review Reference 4 includes an analysis of the NFV. This analysis supports elimination of restrictions imposed for fuel stored in the NFV with enrichments equal to or greater than 3.675 weight percent Uranium-235. The regulatory criteria specific to the NRC staff's review of the revised NCS analysis for the Seabrook NFV is above.
OFFICIAL USE ONLY PROPRIETARY INFORMATION
OFFICIAL USE ONLY PROPRIETARY INFORMATION 4.3.1 Computational Method Monte Carlo N-Particle transport code, version 5 (MCNP5) with Evaluated Nuclear Data File Neutron Data (ENDF/B-V) nuclear data was predominantly used for the NFV analysis. The supporting validation is documented in HOLTEC report Hl-2104790 (Reference 12) and in Appendix A of Hl-2114996 (Reference 9). Section 3.2.2 of Hl-2114996 states the bias and 95 percent probability, 95 percent confidence level, uncertainty from the validation are (( ))
~k and (( )) ~k. respectively. This bias and bias uncertainty are similar to values reported for other analyses.
During review of the computational method validation for use with the NFV kett optimum moderation calculations, it was noted that some ((
)). This does not appropriately cover (( )) because the reactivity of the optimum moderation condition in the NFV is driven by the water between the fuel assemblies, not by
(( )). A more appropriate metric for this situation is the energy of average lethargy of neutrons causing fission (EALF). This quantity better characterizes the neutron energy spectrum seen by the fuel pins in the low moderator density configuration. The Request for Additional Information (RAI) 8 response (Attachment 1 to Reference 4) provided a comparison of the range of the EALF values for the critical experiments used in the validation study with the values from the safety analysis models and showed that it bounded the safety analysis calculation EALF range.
4.3.1.1 Validation of Calculations at Elevated Temperatures Particularly important for low moderation peak kett calculations is validation at elevated temperatures. The Seabrook NFV NCS analysis lacks validation coverage at elevated temperatures.
The validation study used critical experiments with temperatures at approximately (( )). The safety analysis calculations were performed with temperatures of 27°C and 127°C. From Table 3.6.1 in Hl-2114996, the change from 27°C to 100°C increases kett by 0.0497 b.k. Note that for these two conditions, cross-section data at (( )) were used with moderator densities that were a percentage of the full water density at 27°C and 100°C.
At peak reactivity, the kett value rises from 0.9022 to 0.9330. This increase in kett due to temperature variation (i.e. -0.03 b.k) is large enough that variation in kett with temperature should be validated or a suitable margin adopted to cover uncertainty associated with use of elevated temperature data.
To address the temperature-based validation gap in the benchmarking of MCNP for Seabrook NFV kett calculations, the licensee ((
)) as described in the response to RAI 2 (Reference 7). These experiments expand the validation to include experiments with ((
)). The previous validation, including appropriate trending analyses, was updated to include consideration of (( )) and code bias and bias uncertainty OFFICIAL USE ONLY PROPRIETARY INFORMATION
OFFICIAL USE ONLY PROPRIETARY INFORMATION estimates were updated accordingly. The bias increased by 0.0025 ilk and the bias uncertainty increased by 0.0006 ilk, which results a net margin reduction of approximately 0.0025 ilk.
Based on the NRC staff's review, the validation of the criticality code has been appropriately revised to cover NFV modeling at elevated temperatures.
The NRC staff reviewed the computational method and supporting validation and finds them acceptable.
4.3.2 New Fuel Storage Rack Model The Seabrook NFV model is defined by five rows of storage cells with 18 storage cells per row in a tight fitting thick-walled concrete canyon. Assemblies are stored in square tubes with a nominal inner dimension of 9.00 inches and 0.093 inch thick type 304 stainless steel walls. In general, storage cells are nominally spaced with a 21 inch center-to-center cell pitch, with the spacing between the second and third rows and between the third and fourth rows defined by a 33 inch center-to-center cell pitch. Rack structures between storage cells are conservatively omitted. The fuel assembly model includes only the active length of the fuel assembly and conservatively omits grids. The array of fuel assemblies in storage cells is reflected on the sides and bottom by thick concrete and by full density water above the fuel.
In the Seabrook NFV model, no information was provided concerning the composition of the concrete used to model the floor and walls. Due to the tight-fitting concrete walls and floor, the kett of the NFV is sensitive to the concrete composition model.
The response to RAI 1 (Attachment 1 to Reference 4) provided a description of the concrete model used and a statement that "the exact isotopic composition of the concrete and their uncertainties in the Seabrook NFV is unknown." The RAI 1 response did provide some justification for concluding that the concrete model used was conservative. However, the NRC staff performed confirmatory calculations with SCALE 6.1.2 (Reference 14) using the Seabrook NFV concrete model and several other commonly used concrete models (e.g., Magnuson's concrete, Oak Ridge concrete, Rocky Flats Concrete) including "ordinary concrete" as defined in a radiation shielding text book by Chilton, Shultis and Faw (Reference 15). The results indicated that some of the other concrete compositions yielded higher low-moderation peak kett values.
Furthermore, a survey of concrete compositions suggests that the tolerances used in the uncertainty analysis calculations performed for the Seabrook NFV concrete model do not appear to adequately capture the composition variations noted in various references, and the tolerances specified in the RAI 1 response (Attachment 1 to Reference 4) appear to be somewhat arbitrary. Additionally, it does not appear that the potential for time-dependent loss of water from the concrete was considered.
In the response to RAI 1 in Reference 7, the licensee stated that it is known that Portland cement was used in the concrete mixture along with specific details regarding the fine and coarse distributions of the aggregate - this reduces the potential variability of the concrete mixture. Additionally, the licensee notes that ((
OFFICIAL USE ONLY PROPRIETARY INFORMATION
OFFICIAL USE ONLY PROPRIETARY INFORMATION
)).
An updated NFV model was constructed based on more precise knowledge of the concrete aggregate from discussions with "Seabrook site concrete experts." The change in ketr with the updated NFV was found to be minimal for both optimum moderation and full density moderation cases. Only the full density moderation case showed an increase in ketr. and the calculated ketr was updated accordingly as shown in Table 8 of the RAI 2 response (Reference 7); the margin reduction due to refinement of the concrete modeling was calculated to be approximately 0.001 l1k.
Although the RAI 1 response (Reference 7) does update the concrete composition used in the Seabrook NFV criticality model, the response does not discuss the potential for time-dependent loss of water from the concrete. The NRC staff is concerned about the implications of the potential for time-dependent water loss since the response to RAI 1 (Attachment 1 to Reference
- 4) shows that a (( ))
for the optimum moderation case - a substantial change. There is also ((
)) that would be associated with water loss. Based on the
(( )) in the Seabrook NFV concrete, the NRC staff again requested that the licensee determine the impact of time-dependent water loss in the Seabrook NFV concrete. In the response to RAI 1 (Reference 8), the licensee provided adequate justification for the assumed minimum water content in the Seabrook NFV concrete by assuming a water content consistent with Hanford dry concrete as described in Reference 16, which states the following regarding Hanford dry concrete:
Starting from the data in the reference for wet concrete, the water content was reduced to model drying for decades in a dry environment. A reasonable minimum hydrogen content for old dry concrete is about 0.4 weight percent.
In the response to RAI 2 (Reference 8), the licensee provided adequate justification that the water content in the Seabrook NFV concrete cannot decrease below the minimum water content over time as determined in the RAI 1 response based on the licensee's knowledge of:
- water-to-cement ratio used during mixing
- environment relative humidity
- the amount of water that remains "an integral part of the microstructure of cement hydration products and is not lost on drying"
- other sources of water that are present and depend on environment relative humidity Therefore, the NRC staff has reasonable assurance that the water content assumed in the Seabrook NFV criticality analysis is appropriate.
Based on the NRC staff's review of the above, the new fuel storage rack model used in the NFV NCS analysis is acceptable.
OFFICIAL USE ONLY PROPRIETARY INFORMATION
OFFICIAL USE ONLY PROPRIETARY INFORMATION 4.3.3 Design Basis Fuel Assembly The NFV analysis presented in Section 3 of Hl-2114996 (Reference 9) evaluates only the Westinghouse 17x17 RFA fuel assembly design to satisfy the maximum fuel assembly reactivity requirement. Future fuel assembly design changes may require review of the criticality analysis for the NFV.
The fuel assembly design is conservative in that the ((
)). Instead, the fuel is modeled as (( )) uranium dioxide at 5 weight percent Uranium-235. Generally, Seabrook fuel also includes integral fuel burnable absorbers (IFBA) in the form of zirconium diboride on the outside of the fuel pellets. The IFBA coating is conservatively omitted from the NFV calculations and represents significant uncredited margin.
Table 3.6.4 of Hl-2114996 shows that the IFBA coating is worth between 1% and 14% .6k, depending on the number of IFBA rods and the moderator density.
Based on the NRC staff's review of the above, the fuel assembly model used in the NFV NCS analysis is acceptable.
4.3.4 NFV Uncertainty Analysis During the review it was noted that no dimensional uncertainties were provided for the spacing between cells and for the spacing between the cells and the NFV walls. It was also noted that eccentric placement of fuel in the storage cell locations was treated as an uncertainty when it should have been treated as a bias term. The responses to NFV RAls 1 through 8 provided in Reference 4 provide an updated NFV uncertainty analysis and analysis of the impact on the margins to the safety limits. Table 7 and Table 8 in the response to RAI 2 both show the updated tolerances uncertainties (causing an increase of 0.0003 ~k for the optimum moderation case) along with the remaining margin to the corresponding regulatory limits.
Furthermore, the calculated kett values were updated to correspond to the bounding eccentric fuel assembly position as discussed in the response to RAI 6 (Attachment 1 to Reference 4);
only the optimum moderation case was significantly affected resulting in a net increase of 0.0033 ~k.
Based on the NRC staff's review of the above, the uncertainty analysis performed in the NFV NCS analysis is acceptable.
4.4 Technical Conclusion The NRC staff's initial review of the Seabrook NFV NCS analysis documented in Hl-2114996 identified potential non-conservatisms.
For the storage of fuel in the Seabrook NFV, the impact associated with the potential non-conservatisms were evaluated and the available margin to the regulatory limits given in 10 CFR 50.68(b)(2) and 10 CFR 50.68(b)(3) were considered as part of this evaluation.
OFFICIAL USE ONLY PROPRIETARY INFORMATION
OFFICIAL USE ONLY PROPRIETARY INFORMATION The RAI 2 response (Reference 7) shows the net margin reduction as a result of:
- Removal of certain modeling simplifications
- Revision of eccentric fuel assembly positioning treatment
- More precise concrete material specification
- Accounting for potential time-dependent water loss in the concrete
- An updated criticality code validation incorporating ([ ))
The margin to the regulatory limit for the full density moderation case is reduced to 0.0096 ~k and the margin to the regulatory limit for the optimum moderation case is reduced to 0.0187 ~k.
The minimum margin case (0.0096 ~k) occurs for the full density moderation case leaving significant margin to the regulatory limit.
Following review of the supporting analysis reports and based on consideration of the identified non-conservatisms, margins to regulatory limits, and crediting of analysis conservatism, the NRC staff concludes that there is reasonable assurance that the Seabrook NFV fuel assembly storage racks meet the applicable regulatory requirements.
Due to the need to evaluate offsetting effects in the licensee's analysis, the licensee's analysis constitutes a methodology for which any change would be a departure from a method of evaluation described in the Final Safety Analysis Report, as updated, used in establishing the design bases for the NFV.
The NRC staff finds the TS changes acceptable.
5.0 STATE CONSULTATION
In accordance with the Commission's regulations, the New Hampshire and Massachusetts State officials were notified of the proposed issuance of the amendment. The State officials had no comments.
6.0 ENVIRONMENTAL CONSIDERATION
The amendment changes a requirement with respect to installation or use of a facility component located within the restricted area as defined in 10 CFR Part 20. The NRC staff has determined that the amendment involves no significant increase in the amounts, and no significant change in the types, of any effluents that may be released offsite, and that there is no significant increase in individual or cumulative occupational radiation exposure. The Commission has previously issued a proposed finding that the amendment involves no significant hazards consideration, and there has been no public comment on such finding (77 FR 48559, 8/14/12). Accordingly, the amendment meets the eligibility criteria for categorical exclusion set forth in 10 CFR 51.22(c)(9). Pursuant to 10 CFR 51.22(b), no environmental impact statement or environmental assessment need to be prepared in connection with the issuance of the amendment.
OFFICIAL USE ONLY PROPRIETARY INFORMATION
OFFICIAL USE ONLY PROPRIETARY INFORMATION
7.0 CONCLUSION
The Commission has concluded, based on the considerations discussed above, that: (1) there is reasonable assurance that the health and safety of the public will not be endangered by operation in the proposed manner, (2) there is reasonable assurance that such activities will be conducted in compliance with the Commission's regulations, and (3) the issuance of the amendment will not be inimical to the common defense and security or to the health and safety of the public.
8.0 REFERENCES
- 1. NextEra Energy Seabrook, LLC letter SBK-L-11245 to NRC, "Seabrook Station, License Amendment Request 11-04, Changes to the Technical Specifications for New and Spent Fuel Storage," January 30, 2012 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML12038A036).
- 2. NextEra Energy Seabrook, LLC letter SBK-L- 12099 to NRC, "Supplement to LAR 11-04, Changes to the Technical Specifications for New and Spent Fuel Storage," May 10, 2012 (ADAMS Accession No. ML12136A126).
- 3. NextEra Energy Seabrook, LLC letter SBK-L- 12199 to NRC, "Response to Request for Additional Information Regarding License Amendment Request 11-04, Changes to Technical Specifications for New and Spent Fuel Storage," September 20, 2012 (ADAMS Accession No. ML12271A276).
- 4. NextEra Energy Seabrook, LLC letter SBK-L-13061 to NRC, "Seabrook Station, Response to December 2012 Request for Additional Information Regarding License Amendment Request 11-04, Changes to the Technical Specifications for New and Spent Fuel Storage,"
March 27, 2013 (ADAMS Accession No. ML13099A022).
- 5. NextEra Energy Seabrook, LLC letter SBK-L- 13224 to NRC, "Request for Review and Approval of License Amendment Request (LAR) 11-04, Changes to Technical Specifications for New and Spent Fuel Storage, in Two Parts," December 20, 2013 (ADAMS Accession No. ML13360A045).
- 6. NextEra Energy Seabrook, LLC letter SBK-L-14018 to NRC, "Response to Request for Additional Information for License Amendment Request 11-04, Changes to Technical Specifications for Spent Fuel Storage," January 29, 2014 (ADAMS Accession No. ML14035A218).
- 7. NextEra Energy Seabrook, LLC letter SBK-L-14053 to NRC, "Seabrook Station, Response to Request for Additional Information for License Amendment Request 11-04, Changes to the Technical Specifications for New Fuel Vault," March 13, 2014 (ADAMS Accession No. ML14078A057).
OFFICIAL USE ONLY PROPRIETARY INFORMATION
OFFICIAL USE ONLY PROPRIETARY INFORMATION
- 8. NextEra Energy Seabrook, LLC letter SBK-L-14053 to NRC, "Seabrook Station, Response to Request for Additional Information for License Amendment Request 11-04, Changes to the Technical Specifications for New Fuel Vault," February 25, 2015 (ADAMS Accession No. ML15065A029).
- 9. HOLTEC International report, "Licensing Report for Seabrook Spent Fuel Pool and New Fuel Vault Analyses," Hl-2114996, Rev. 3, HOLTEC International, Marlton, NJ, March 2013.
- 10. HOLTEC International report, "Licensing Report for Seabrook Spent Fuel Pool and New Fuel Vault Analyses," Hl-2114996, Rev. 2, HOLTEC International, Marlton, NJ, January 2012.
- 11. NRC Division of Safety Systems Interim Staff Guidance DSS-ISG-2010-01, Rev. 0, "Staff Guidance Regarding the Nuclear Criticality Safety Analysis for Spent Fuel Pools,"
October 13, 2011 (ADAMS Accession No. ML110620086).
- 12. HOLTEC International Report, "Nuclear Group Computer Code Benchmark Calculations",
Holtec Report Hl-2104790, Rev. 0, January 2011.
- 13. Il 11
- 14. Scale: A Comprehensive Modeling and Simulation Suite for Nuclear Safety Analysis and Design, ORNL/TM-2005/39, Version 6.1, Oak Ridge National Laboratory, Oak Ridge, Tenn.,
June 2011. Available from Radiation Safety Information Computational Center at Oak Ridge National Laboratory as CCC-785.
- 15. A.B. Chilton, J.K. Shultis, and R.E. Faw, Principles of Radiation Shielding, PRENTICE-HALL, INC., Englewood Cliffs, NJ, 1984.
- 16. PNNL-15870, Rev. 1, "Compendium of Material Composition Data for Radiation Transport Modeling," 2011.
Principal Contributor: Amrit Patel Date: May 18, 2015 OFFICIAL USE ONLY PROPRIETARY INFORMATION
Package: ML15118A637 Non-Proprietary SE: ML15118A632 AMO- ML15118A632 Proprietary SE: ML15118A635
- via memo **via e-mail OFFICE LPL 1-2/PM LPL 1-2/LA SRXB/BC* OGC LPL 1-2/BC LPL 1-2/PM KWood DBroaddus NAME JLamb ABaxter** (CJackson For) BMizuno (JWhited For) JLamb DATE 05/07/2015 04/30/2015 03/24/2015 05/08/2015 05/08/2015 05/18/2015