CONTAINMENT SYSTEMS PRIMARY CONTAINMENT CONTAINMENT AIR-LOCKS SURVEILLANCE REQUIREMENTS 4.6.1.3 Each containment air lock shall be demonstrated OPERABLE:

a.

With the leakage rate In accordance with the Containment Leakage Rate Testing Program.

b.

At least once per 24 months by verifying that only one door in each air lock can be opened at a time.

SEABROOK - UNIT I 3/4 6-8 Amendment No. 49,106