Name: ________________________________ ILC-14 RO NRC Exam Form: 0 Version: 0

1. Given the following plant conditions:

- The reactor has tripped due to a pressurizer steam space leak

- Safety Injection has automatically initiated Which ONE(1) of the following completes the statement below?

The MINIMUM values specified by EOP-E-0, REACTOR TRIP OR SAFETY INJECTION, to transition to EPP-7, SI TERMINATION, to terminate Safety Injection are RCS pressure greater than (1) PSIG and RCS subcooling based on core exit TCs greater than (2) degrees F.

A. (1) 1650 (2) 30 B. (1) 1650 (2) 35 C. (1) 1715 (2) 30 D. (1) 1715 (2) 35 Tuesday, September 23, 2014 11:14:20 AM 1

ILC-14 RO NRC Exam

2. Given the following plant conditions:

Initial conditions:

- Reactor Power is 100%

- Pressurizer level control and letdown is in a normal automatic alignment

- Only Charging pump B is running and its speed controller is in AUTO Current conditions:

- Pressurizer Safety Valve RC-551A, fails 100% open

- RCS pressure is 2075 PSIG and lowering slowly

- Reactor will NOT trip Which ONE(1) of the following completes the statements below?

RC-551A's lift set point is (1) psig.

Based on current plant conditions, long term, LC-459G, MASTER PRESSURIZER LEVEL CONTROLLER, demand signal will (2) .

A. (1) 2335 (2) lower B. (1) 2335 (2) rise C. (1) 2485 (2) lower D. (1) 2485 (2) rise Tuesday, September 23, 2014 11:14:20 AM 2

ILC-14 RO NRC Exam

3. Given the following plant conditions:

- The unit was initially at 100% power

- A LOCA has occurred

- RCS pressure is 1300 psig and lowering

- Tave is 548 F

- Containment pressure peaked at 4.2 psig

- The crew is performing actions of EPP-8, Post LOCA Cooldown and Depressurization As directed by EPP-8 which one of the following identifies the method that will be used to initiate cooldown of the RCS?

Initiate cooldown using the...

A. steam dumps at the maximum achievable rate B. steam dumps at no greater than 100°F/hr in the last 60 minutes C. steam line PORVs at the maximum achievable rate D. steam line PORVs at no greater than 100°/hr in the last 60 minutes Tuesday, September 23, 2014 11:14:20 AM 3

ILC-14 RO NRC Exam

4. Given the following plant conditions:

- Unit 2 has suffered a LBLOCA

- Restoration efforts are in progress with the following plant conditions:

- Core Exit Thermocouples are currently reading 720oF

- Full Range RVLIS is 45%

- CV Pressure is currently 11 psig

- CV Sump Level is 350 inches and rising

- CV Radiation Levels are > 5 R/hr

- CV Spray Pumps "A" & "B" have tripped FRP-C.1, Response to Inadequate Core Cooling FRP-C.2, Response to Degraded Core Cooling FRP-J.1, Response to High Containment Pressure FRP-J.2, Response to Containment Flooding Which ONE(1) of the following completes the statements below?

Based on the indications above, which Function Restoration Procedures(FRP's) have met entry criteria IAW Critical Safety Function Status Trees(CSFST's):

A. FRP-C.1 and FRP-J.1 B. FRP-C.1 and FRP-J.2 C. FRP-C.2 and FRP-J.1 D. FRP-C.2 and FRP-J.2 Tuesday, September 23, 2014 11:14:20 AM 4

ILC-14 RO NRC Exam

5. Given the following plant conditions:

- The plant is at 100% power

- At 0200 the Reactor Operator determined that Seal Injection flow was lost to RCP A

- The following RCP "A" conditions existed at that time 0205:

Pump Bearing #1 Seal Leakoff Temperature Shaft Vibrations Temperature 166ºF 15.2 Mils 148ºF

- It is now 0215 and the following RCP "A" conditions exist:

Pump Bearing #1 Seal Leakoff Temperature Shaft Vibrations Temperature 231ºF 15.3 Mils 222ºF Which ONE(1) of the following completes the statement below?

IAW AOP-018, REACTOR COOLANT PUMP ABNORMAL CONDITIONS, the RCP .

A. operation may continue. There are no parameters requiring immediate RCP shutdown.

B. must be shut down due to pump bearing temperature exceeding operating limits.

C. must be shut down due to pump shaft vibration exceeding operating limits.

D. must be shut down due to #1 seal leakoff temperature exceeding operating limits.

Tuesday, September 23, 2014 11:14:20 AM 5

ILC-14 RO NRC Exam

6. Given the following plant conditions:

- Shutdown with the RHR System aligned for core cooling

- RCS level is at (-) 69 inches and stable as read on LI-403 and LI-404

- Steam Generator Primary Manway removal in progress

- The "A" RHR pump is running

- RHR System total flow is oscillating from 2800 to 3500 gpm

- "A" RHR pump discharge pressure is oscillating

- RHR HX LO FLOW annunciator, APP-001-A7 alarming Based on the above conditions, with of the following identifies the FIRST correct action to mitigate the events as directed by AOP-020, LOSS OF RESIDUAL HEAT REMOVAL.

A. Raise RCS Level B. Reduce RHR flow C. Stop the "A" RHR Pump D. Stop the "B" RHR Pump Tuesday, September 23, 2014 11:14:20 AM 6

ILC-14 RO NRC Exam

7. Given the following plant conditions:

The control room operating crew has entered FRP-C.2 Response to Degraded Core Cooling and the following plant conditions exist:

- RCP "A" is running

- RCP's "B" & "C" have been secured

- CCW flow to RCP "A" motor has just been lost

- RCP "A" upper thrust bearing temperature has risen to 205 °F Based on the above conditions, which one of the following choices:

(1) describes whether RCP "A" is required to be immediately secured?

(2) the reason for either securing RCP "A" or allowing it to run?

A. (1) RCP "A" is required to be immediately secured (2) bearing and motor damage could occur B. (1) RCP "A" is required to be immediately secured (2) RCP "A" could be pumping two-phase flow through the core C. (1) RCP "A" is NOT required to be immediately secured (2) PZR spray is being supplied by loop "A" D. (1) RCP "A" is NOT required to be immediately secured (2) RCP "A" is providing single or two-phase flow through the core Tuesday, September 23, 2014 11:14:20 AM 7

ILC-14 RO NRC Exam

8. Given the following plant conditions:

- The plant is operating at 100% RTP

- A failure of the pressurizer pressure Master Controller, PC-444J, results in actual pressure lowering to 2185 psig and continuing to lower Which ONE(1) of the following completes the statements below?

If PC-444J is placed in manual per the IMMEDIATE ACTIONS of AOP-019, Malfunction of RCS Pressure Control, the controllers __ _(1) arrow would be initially depressed to regain pressure control.

If spray valve PCV-455A would not close and the reactor was tripped due to lowering pressure, then the minimum RCP(s) required to be secured per EOP-E-0, Reactor Trip or Safety Injection, to stop spray flow is/are RCP ___(2)____.

A. (1) down (2) "B" & "C" B. (1) down (2) "C" C. (1) up (2) "B" & "C" D. (1) up (2) "C" Tuesday, September 23, 2014 11:14:20 AM 8

ILC-14 RO NRC Exam

9. Given the following plant conditions:

A primary system pipe break with a failure of the reactor to trip (ATWS) has resulted in the following plant conditions:

- Reactor Power is 12% and lowering

- CV Pressure is 12 psig and rising Which ONE(1) of the following completes the statements below?

For the above conditions, FRP-S.1 Response to Nuclear Power Generation/ATWS states that RCPs ____(1)____ be tripped.

Per FRP-S.1, if the Main Turbine is unable to be tripped, uncontrolled RCS cooldown is prevented by FIRST performing a ____(2)____ .

A. (1) should (2) Turbine runback B. (1) should (2) closure of all MSIV's C. (1) should NOT (2) Turbine runback D. (1) should NOT (2) closure of all MSIV's Tuesday, September 23, 2014 11:14:20 AM 9

ILC-14 RO NRC Exam

10. Given the following plant conditions:

- The plant is at 100% RTP

- The following Radiation Monitors go into alarm:

- Condenser Air Ejector Gas Monitor, R-15

- Condensate Polisher Waste Effluent Monitor, R-37

- S/G Sample Radiation Monitor, R-19A

- "A" Main Steam Line N-16 Detector, R-24A Which ONE(1) of the following describes the correct response to the above given conditions?

A. Condensate Polishing Building Sump pumps TRIP.

V1-31, Blowdown Isolation Valve to Catch Basin, CLOSES.

B. FCV-1933A and B, S/G A Blowdown Sample Isolation Valves, CLOSE.

Condensate Polishing Building Sump pumps TRIP.

C. FCV-1933A and B, S/G A Blowdown Sample Isolation Valves, CLOSE.

RCV-10549, Condensate Polisher Discharge to Storm Drains, CLOSES.

D. V1-31, Blowdown Isolation Valve to Catch Basin, CLOSES.

RCV-10549, Condensate Polisher Discharge to Storm Drains, CLOSES.

11. Given the following plant conditions:

- All Steam Generators are faulted Which ONE(1) of the following completes the statement below?

is the basis for a minimum of 80 gpm indicated AFW flow to each Steam Generator per EPP-16, UNCONTROLLED DEPRESSURIZATION OF ALL STEAM GENERATORS.

A. Preventing Steam Generator dryout B. Prevent water hammer in the feed rings C. Meeting minimum heat sink flow requirements D. Ensure the feed lines stay warm to prevent excessive thermal shock to the feed lines during recovery actions Tuesday, September 23, 2014 11:14:20 AM 10

ILC-14 RO NRC Exam

12. Given the following plant conditions:

- The unit has entered EOP-E-0, REACTOR TRIP OR SAFETY INJECTION, due to a Safety Injection

- Steam generator narrow range levels following the reactor trip lowered to and are currently:

- S/G "A" is 16% and stable

- S/G "B" is 17% and stable

- S/G "C" is 17% and stable

- Operators are currently performing the step in EOP-E-0 that says "Check AFW Pumps- RUNNING" Which ONE(1) of the following completes the statement below?

The SDAFW pump is (1) . IAW with EOP-E-0, the crew will (2) .

A. (1) OFF (2) manually start the SDAFW pump B. (1) OFF (2) check AFW header section valves FULL OPEN C. (1) ON (2) manually stop the SDAFW pump D. (1) ON (2) check SDAFW pump discharge valves FULL OPEN Tuesday, September 23, 2014 11:14:20 AM 11

ILC-14 RO NRC Exam

13. Given the following plant conditions:

- A cool down of <100°F/hr is in progress per EPP-1, Loss of All AC, using Steam Line PORVs Which ONE(1) of the following completes the statements below?

IAW EPP-1, the crew will depressurize intact S/G's to (1) psig. During the depressurization, the crew will check RCS Cold Leg Temperatures greater than (2) °F.

A. (1) 140 (2) 355 B. (1) 140 (2) 290 C. (1) 240 (2) 355 D. (1) 240 (2) 290 Tuesday, September 23, 2014 11:14:20 AM 12

ILC-14 RO NRC Exam

14. Given the following plant conditions:

Initial Conditions:

- Unit 2 was at 100% power

- A Loss of all Offsite Power (LOOP) has occurred

- Operators entered EPP-5, NATURAL CIRCULATION COOLDOWN Current Conditions:

- Emergency Diesel Generators continue to operate normally

- Operators have just completed the step in EPP-5 to check cool down rate required -GREATER THAN limits, and have determined that a transition to EPP-6, NATURAL CIRCULATION COOL DOWN WITH STEAM VOID IN VESSEL, is not required

- CRDM Cooling Fan HVH-5A is running

- CRDM Cooling Fan HVH-5B is NOT running Which ONE(1) of the following completes the statement below?

IAW EPP-5, the MINIMUM value for subcooling is (1) oF and you must cool down less than (2) oF/hr to preclude formation of a steam void in the vessel upper head.

A. (1) 55 (2) 10 B. (1) 100 (2) 10 C. (1) 55 (2) 25 D. (1) 100 (2) 25 Tuesday, September 23, 2014 11:14:20 AM 13

ILC-14 RO NRC Exam

15. Given the following plant conditions:

- Unit was at 100% power

- Loss of a Vital Instrument Bus occurred

- The control room crew has just completed the Immediate Actions of AOP-024, LOSS OF INSTRUMENT BUS The Immediate Action, Place the Main Turbine in Manual, is procedurally directed to be performed for loss of ANY Instrument Bus, without taking time at that point to diagnose which bus was lost.

Which ONE(1) of the following completes the statements below?

The BASIS for the action is to mitigate the effects of a loss of Instrument Bus (1) .

This is because a continuous turbine Load Reference runback would occur if the turbine were in Automatic, making an automatic reactor trip unavoidable because all (2) .

A. (1) 1 (2) Pressurizer spray valve control is lost B. (1) 1 (2) Feedwater Regulating Valve M/A stations are lost C. (1) 4 (2) Pressurizer spray valve control is lost D. (1) 4 (2) Feedwater Regulating Valve M/A stations are lost Tuesday, September 23, 2014 11:14:20 AM 14

ILC-14 RO NRC Exam

16. Given the following plant conditions:

- Plant is at 35% RTP

- APP-002-E7 (INST AIR COMP D TRIP) in alarm

- APP-002-F7 (INST AIR HDR LO PRESS) in alarm

- AOP-017 (LOSS OF INSTRUMENT AIR) is in progress

- Station Air and Instrument Air have been cross-connected

- Transition has been made to AOP-017; Section A (Modes 1 AND 2)

- Instrument Air pressure is 63 psig

- "B" and "C" S/Gs Levels are at 41% and slowly lowering Which ONE(1) of the following completes the statment below?

The operating crew is required to_____ while continuing in AOP-017.

A. dispatch operator(s) to cross-connect Station Air and Construction Air B. trip the reactor and Go to EOP-E-0 (Reactor Trip Or Safety Injection)

C. trip the turbine and implement AOP-007 (Turbine Trip below P-8)

D. lower turbine load as necessary to maintain feed and steam flows matched Tuesday, September 23, 2014 11:14:20 AM 15

ILC-14 RO NRC Exam

17. Which ONE(1) of the following completes the statements below?

In accordance with EPP-20, LOCA OUTSIDE CONTAINMENT:

The FIRST flowpath to be isolated from the RCS when attempting to isolate an RCS leak outside containment will be associated with (1) .

The RCS parameters to be monitored to confirm that the RCS leak has or has NOT been isolated is (2) .

A. (1) RHR (2) RCS Pressure B. (1) RHR (2) PZR Level C. (1) RCP Seal Return (2) RCS Pressure D. (1) RCP Seal Return (2) PZR Level Tuesday, September 23, 2014 11:14:20 AM 16

ILC-14 RO NRC Exam

18. Given the following plant conditions:

- A reactor trip has occurred due to a trip of both Main Feed Pumps

- The following conditions exist:

- The crew has recently entered FRP-H.1, RESPONSE TO LOSS OF SECONDARY HEAT SINK, after completion of immediate actions of EOP-E-0, REACTOR TRIP OR SAFETY INJECTION

- The BOP operator notes the following annunciators are lit:

- APP-007-F1, AFW PMP A LO DISCH PRESS/MTR TRIP

- APP-007-F2, AFW PMP B LO DISCH PRESS/MTR TRIP

- APP-007-F5, SDAFW PMP LO DISCH PRESS TRIP

- SG wide range levels are: A: 8 % B: 15 % C: 16 %

- All SG pressures are 1035 psig

- RCS pressure is 2300 psig

- CST level is 5% and lowering due to sabotage and is INACCESSIBLE

- Condensate System is AVAILABLE OP-402, AUXILIARY FEEDWATER SYSTEM Attachment 2 of FRP-H.1, SW BACKUP TO MDAFW PUMPS Which ONE(1) of the following completes the statements below?

In accordance with FRP-H.1, based on the CST concerns, Service Water backup supply is required to be aligned to both (1) .

After action has been taken to address the CST concerns, for the given conditions, the NEXT major action taken to restore heat sink IAW FRP-H.1 is to (2) .

A. (1) MDAFW pumps AND SDAFW pump IAW OP-402 (2) initiate RCS Bleed and Feed B. (1) MDAFW pumps ONLY IAW Attachment 2 of FRP-H.1 (2) initiate RCS Bleed and Feed C. (1) MDAFW pumps AND SDAFW pump IAW OP-402 (2) attempt to establish Main Feedwater flow D. (1) MDAFW pumps ONLY IAW Attachment 2 of FRP-H.1 (2) attempt to establish Main Feedwater flow Tuesday, September 23, 2014 11:14:20 AM 17

ILC-14 RO NRC Exam

19. The plant is at 100% power when the requirements of LCO 3.2.4, QPTR, are not satisfied.

Which ONE(1) of the following completes the statements below?

The maximum power level at which the LCO will no longer apply is (1)  %. The reason for the power level stated in the LCO applicability statement is to (2) .

A. (1) 15 (2) prevent unanalyzed xenon effects on power distribution during subsequent power increases B. (1) 15 (2) achieve a condition where the Quadrant Power Distribution is no longer a significant concern to safety analyses C. (1) 50 (2) prevent unanalyzed xenon effects on power distribution during subsequent power increases D. (1) 50 (2) achieve a condition where the Quadrant Power Distribution is no longer a significant concern to safety analyses Tuesday, September 23, 2014 11:14:20 AM 18

ILC-14 RO NRC Exam

20. Given the following plant conditions:

- Turbine load was reduced from 95 to 90% to support scheduled maintenance.

- Control Bank D was inserted from 210 to 197 steps during the load reduction for axial flux control.

- At 90% power, the Reactor Operator immediately reports that two of the Control Bank D rods, D-8 and H-8, IRPI(s) remain at 210 steps and did not appear to move.

- APP-005-E2, ROD CONT SYSTEM URGENT FAILURE - NOT illuminated

- All Power Range NIs indicate 90%

Which ONE(1) of the following completes the statements below?

In accordance with AOP-001, Malfunction of Reactor Control System, UNTIL the problem is determined to be either an IRPI indicator(s) issue or actual stuck rods, Tave may be maintained on program using (1) .

SUBSEQUENTLY, I&C Maintenance and Reactor Engineering support determined that the problem with D-8 was an IRPI indication problem and only H-8 is misaligned.

All Lift Coil Disconnect Switches for Control Bank D rods except H-8 (2) be placed in the OFF position to support rod realignment per AOP-001, Section B.

A. (1) Turbine load adjustment (2) will B. (1) Turbine load adjustment (2) will NOT C. (1) Control Bank D (2) will D. (1) Control Bank D (2) will NOT Tuesday, September 23, 2014 11:14:21 AM 19

ILC-14 RO NRC Exam

21. Given the following plant conditions:

Initial conditions:

- Unit 2 was at 100% power

- A manual reactor trip was unsuccessfully attempted due to a Feedwater Controller malfunction

- The crew has entered FRP-S.1, RESPONSE TO NUCLEAR POWER GENERATION/ATWS Current Conditions:

- Operators have just reached the step in FRP-S.1 to initiate Emergency Boration Which ONE(1) of the following completes the statements below?

To maximize borated water flow to the RCS, FRP-S.1 states that the HIC-121 potentiometer, Charging Controller - DEMAND SIGNAL is to be established at ____(1)____ %.

Per FRP-S.1, ____(2)____ is the preferred, highest Boration rate, Charging Pump supply source.

MOV-350, BA TO CHARGING PMP SUCT CVC-358, RWST TO CHARGING PUMP SUCTION A. (1) 0 (2) MOV-350 B. (1) 0 (2) CVC-358 C. (1) 100 (2) MOV-350 D. (1) 100 (2) CVC-358 Tuesday, September 23, 2014 11:14:21 AM 20

ILC-14 RO NRC Exam

22. Given the following plant conditions:

- The plant is operating at 100% RTP

- A Charging Pump is in Auto and its speed is lowering

- Pressurizer Backup Group A heaters are in AUTO and have energized

- Backup Group B heaters are in ON Which ONE(1) of the following completes the statements below?

Based on these indications, the reference leg for (1) is leaking. With no operator action, a letdown isolation signal will eventually occur. Following the isolation, Backup Group B heaters will be (2) .

A. (1) LT-459 (2) energized B. (1) LT-460 (2) energized C. (1) LT-459 (2) de-energized D. (1) LT-460 (2) de-energized Tuesday, September 23, 2014 11:14:21 AM 21

ILC-14 RO NRC Exam

23. Given the following plant conditions:

- 0800 The reactor is shut down in Mode 6 and refueling of the core is in progress.

All Source Range Nuclear Instrument channels and Post Accident Monitor Source Range channels are operable. Audio count rate is operable and selected to N-32.

- 0810 Source Range Nuclear Instrument channel N-31 power supply failure causes detector supply voltage to slowly lower by approximately 200 volts.

- 0820 N-31 power supply output is 0 volts and N-31 has been declared inoperable.

Which ONE(1) of the following completes the statements below?

At 0810 Control room indication of N-31 will be (1) as compared to N-32.

At 0825 the crew commences the required logging associated with PAM instrumentation.

At 0830 In accordance with Tech Spec 3.9.2, core alterations (2) continue.

A. (1) the same (2) may B. (1) the same (2) may NOT C. (1) lower (2) may D. (1) lower (2) may NOT Tuesday, September 23, 2014 11:14:21 AM 22

ILC-14 RO NRC Exam

24. Given the following plant conditions:

- Power ascension is in progress during a plant startup with the following power range nuclear instrument readings:

- N-41 = 10.5%

- N-42 = 10.5%

- N-43 = 9.0%

- N-44 = 9.5%

- Intermediate range nuclear instrument (N-35) has been declared inoperable due to a loss of its compensating voltage.

- Per APP-005, the CRS has directed you to bypass N-35 in accordance with OWP-001, NUCLEAR INSTRUMENTATION.

- You have just placed the intermediate range level trip switch for N-35 in the BYPASS position.

Given the above plant conditions, which one of the following describes the status of LCO 3.3.1, RPS ISNTRUMENTATION, for the Intermediate Range Neutron Flux Function AND the actions (if any) that are needed to comply with LCO 3.3.1?

A. 3.3.1 is NOT applicable because power is >P-10 B. 3.3.1 is NOT applicable because power is >P-6 but <P-10 C. 3.3.1 is applicable, power must be lowered <P-6 D. 3.3.1 is applicable, raise thermal power >P-10 Tuesday, September 23, 2014 11:14:21 AM 23

ILC-14 RO NRC Exam

25. Given the following plant conditions:

- Unit 2 is at 100% power

- Control Room Air Cleaning Fan, HVE-19A, is tagged out for scheduled motor inspection

- A valid high radiation alarm on R-1 occurs Which ONE(1) of the following completes the statement below?

Control room exhaust fan, HVE-16, is shutdown (1) and Aux Building Supply Fan, HVS-1 (2) required to be shutdown.

A. (1) automatically (2) is B. (1) automatically (2) is NOT C. (1) manually (2) is D. (1) manually (2) is NOT Tuesday, September 23, 2014 11:14:21 AM 24

ILC-14 RO NRC Exam

26. Given the following plant conditions:

- Unit 2 is currently operating at 100% RTP

- A fire has been reported in a LHRA Which ONE(1) of the following completes the statement below?

IAW FP-001, FIRE EMERGENCY, prior to authorizing entry into this fire area, a Radiological Controls (RC) brief ____(1)____ required and an RC Technician

____(2)____ required to enter the area with the Fire Brigade.

A. (1) is still (2) is B. (1) is NOT (2) is C. (1) is still (2) is NOT D. (1) is NOT (2) is NOT Tuesday, September 23, 2014 11:14:21 AM 25

ILC-14 RO NRC Exam

27. Given the following plant conditions:

- A loss of off-site power occurred 15 minutes ago

- The crew is performing EOP-ES-0.1, Reactor Trip Response

- The BOP is verifying Natural Circulation in accordance with ES-0.1 Attachment 1, Natural Circulation Verification:

- RCS pressure is 1800 psig and stable

- SG pressures are all 1000 lowering

- RCS Thot is 586oF and trending down

- RCS Tcold is 547oF and trending down

- Core Exit Thermocouple temperature is 591oF and trending down Which ONE(1) of the following completes the statement below?

The Natural Circulation criteria in Attachment 1 (1) met. Over the next 60 minutes, RCS Core Delta T will (2) .

A. (1) are (2) lower B. (1) are (2) rise C. (1) are NOT (2) lower D. (1) are NOT (2) rise Tuesday, September 23, 2014 11:14:21 AM 26

ILC-14 RO NRC Exam

28. Given the following plant conditions:

- Unit 2 was at 35% power, End of Life (EOL) following 300 days of continuous operation

- A bus fault has resulted in loss of 4kV Bus 4 Which ONE(1) of the following completes the statement below?

Based on the current conditions, RCP B has tripped on ____(1)____ .

Two minutes following the loss of RCP B, SG B steam flow is ____(2)____ than SGs "A" and "C".

A. (1) under-frequency (2) higher B. (1) under-frequency (2) lower C. (1) under-voltage (2) higher D. (1) under-voltage (2) lower Tuesday, September 23, 2014 11:14:21 AM 27

ILC-14 RO NRC Exam

29. Given the following plant conditions:

- The following sequence of events has occurred on Unit 2:

- 0900: CVC-381, RCP Seal Return Isolation is closed and cannot be re-opened

- 0903: Receipt of annunciator APP-001-C1, RCP THERM BAR COOL WTR HI FLOW

- 0904: Receipt of annunciator APP-001-D1, RCP THERM BAR COOL WTR LO FLOW

- 0905: Unit 2 is at 70% RTP Which ONE(1) of the following completes the statement below?

Based on these conditions, a #1 seal return flow-path is still available to the ___(1)___ . AOP-014 (2) state that the RCP should be secured within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

Reactor Coolant Drain Tank (RCDT)

Pressurizer Relief Tank (PRT)

A. (1) RCDT (2) is B. (1) PRT (2) is C. (1) RCDT (2) is NOT D. (1) PRT (2) is NOT Tuesday, September 23, 2014 11:14:21 AM 28

ILC-14 RO NRC Exam

30. Given the following plant conditions:

- The plant is operating at 100% power with CVCS in its normal letdown alignment when the Letdown Temperature element (TE-144) fails upscale.

- Pressurizer Pressure Control is in MANUAL

- Rod Control is in MANUAL Which ONE(1) of the following completes the statement below?

Based on the conditions above, VCT/Demineralizer Diversion Valve (TCV-143, NON GEN HX OUTLET TEMP) will ___(1)___ and RCS temperature and pressure will ___(2)___.

A. (1) bypass the demineralizers (2) remain unchanged B. (1) bypass the demineralizers (2) lower C. (1) maintain its current position (2) rise D. (1) maintain its current position (2) lower Tuesday, September 23, 2014 11:14:21 AM 29

ILC-14 RO NRC Exam

31. Given the following plant conditions:

- A Large Break LOCA and Loss of Offsite Power have occurred

- EDG B tripped while starting

- RWST level is 9%

- Alignment to the CV Sump has been completed

- CV Pressure is currently 12 psig Which ONE(1) of the following completes the statement below?

SI-844A and B, CV Spray Pump Suction Isolation Valves, will be (1) . RHR Pump A (2) capable of supplying suction to CV Spray Pump B.

A. (1) closed (2) IS B. (1) closed (2) IS NOT C. (1) open (2) IS D. (1) open (2) IS NOT Tuesday, September 23, 2014 11:14:21 AM 30

ILC-14 RO NRC Exam

32. Given the following plant conditions:

- Plant startup activities following a refueling outage are in progress

- The Pressurizer is solid

- RCP "A" is running

- PCV-145, LOW PRESSURE LETDOWN VALVE, has been placed in MANUAL

- GP-002, COLD SHUTDOWN TO HOT SUBCRITICAL AT NO LOAD TAVG, Section 8.2 (Instructions for Plant Heatup up to 199ºF) is in progress

- RCS temperature is 143º F and rising HCV-758, RHR HX DISCH FLOW FCV-605, RHR HX BYPASS VALVE Which ONE(1) of the following completes the statement below?

As the RCS heats up the operators will adjust PCV-145 by pushing the (1) button to control RCS pressure. The operators will throttle (2) to control RCS heat up rate.

A. (1) down (2) HCV-758 B. (1) down (2) FCV-605 C. (1) up (2) HCV-758 D. (1) up (2) FCV-605 Tuesday, September 23, 2014 11:14:21 AM 31

ILC-14 RO NRC Exam

33. Given the following plant conditions:

- The reactor is at 100% RTP

- A CV Vacuum release is in progress

- A Safety Injection signal is received PCV-1922 A/B, CONTAINMENT ISOLATION VALVE SEAL WATER (IVSW)

RHR-744 A/B, LOOP DISCHARGE TO RCS ISOLATION VALVES V12-12/13, VACUUM RELIEF VALVES SI-867 A/B, BIT INJECTION TANK INLETS Which of the following valves will NOT reposition automatically due the above conditions?

A. PCV-1922 A/B B. V12-12/13 C. SI-867 A/B D. RHR-744 A/B Tuesday, September 23, 2014 11:14:21 AM 32

ILC-14 RO NRC Exam

34. Given the following plant conditions:

- The unit is at 100% power

- APP-003-B3, PRT HI TEMP, is in alarm

- The station is addressing a gradual rising PRT temperature and level due to seat leakage on a pressurizer safety valve as a mitigating action until the unit is removed from service for repairs.

Which ONE(1) of the following completes the statement below?

In accordance with APP-003-B3, Pressurizer Relief Tank Control System, actions to drain the PRT and makeup with primary water ___(1)___ allowed to be performed simultaneously.

If the leaking pressurizer safety valve subsequently fails open, the PRT is protected from exceeding its design pressure by rupture disks that operate at the minimum pressure of ___(2)____ psig.

A. (1) are (2) 100 B. (1) are (2) 120 C. (1) are NOT (2) 100 D. (1) are NOT (2) 120 Tuesday, September 23, 2014 11:14:21 AM 33

ILC-14 RO NRC Exam

35. Given the following plant conditions:

- The plant is at 100% power, steady-state

- The controller for TCV-144, NON-REGEN HX OUTLET TEMP CONTROL VALVE, has just been placed in MANUAL due to erratic operation Subsequently

- A 60 gpm orifice is placed in service, replacing the 45 gpm orifice that had been in service by itself

- No adjustments have been made to TCV-144 Which ONE(1) of the following completes the statements below?

Reactor Coolant System temperature will (1) due to reactivity effects. If letdown temperature continues to rise, TCV-143, VCT/DEMIN DIVERSION, will divert letdown flow to the VCT at (2) .

A. (1) rise (2) 130º F B. (1) rise (2) 135º F C. (1) lower (2) 130º F D. (1) lower (2) 135º F Tuesday, September 23, 2014 11:14:21 AM 34

ILC-14 RO NRC Exam

36. Given the following plant conditions:

- Unit is in Mode 2

- The crew is performing actions of AOP-014, Component Cooling Water System Malfunction, Section D, due to low CCW System flow and rising temperature Which ONE(1) of the following completes the statement below?

Any Reactor Coolant Pump whose (1) bearing temperature exceeds (2) must be stopped.

A. (1) motor (2) 185º F B. (1) pump (2) 185º F C. (1) motor (2) 200º F D. (1) pump (2) 200º F Tuesday, September 23, 2014 11:14:21 AM 35

ILC-14 RO NRC Exam

37. Given the following plant conditions:

- The plant is operating at 100% power

- Charging pump "A" is running in AUTO

- Charging pump "B" is running in MAN at 20% demand

- Pressurizer level control switch, LM-459 is selected to NORM

- Pressurizer Backup Heater "A" Switch is ON

- All other control systems are in AUTO Subsequently:

- Pressurizer level transmitter, LT-460, fails downscale Which ONE(1) of the following completes the statements below?

Charging Pump "A" speed will (1) and APP-003-B7, PZR PROT LO LEVEL (2) illuminate.

A. (1) rise (2) will B. (1) lower (2) will C. (1) rise (2) will NOT D. (1) lower (2) will NOT Tuesday, September 23, 2014 11:14:21 AM 36

ILC-14 RO NRC Exam

38. Given the following plant conditions:

- MST-021, Reactor Protection Logic Train B at Power, is currently in progress with the following configuration:

- A Trip Breaker is racked in and closed

- A Bypass Breaker is racked out

- B Trip Breaker is racked in and open

- B Bypass Breaker is racked in and closed

- The Unit CRS has determined that conditions requiring a Manual Trip have been met. Upon actuation of BOTH RTGB Manual Trip Pushbuttons by the OAC, the reactor has failed to trip.

- No AUTOMATIC trip setpoints have been reached Which ONE(1) of the following completes the statements below?

Based on the above conditions, the B Bypass Breaker ____(1)____ could have contributed to the failure of the reactor to TRIP. The crew ____(2)____ required to enter EOP-E-0, Reactor Trip or Safety Injection.

A. (1) Shunt Trip Coil (2) is B. (1) Under-voltage Coil (2) is C. (1) Shunt Trip Coil (2) is NOT D. (1) Under-voltage Coil (2) is NOT Tuesday, September 23, 2014 11:14:21 AM 37

ILC-14 RO NRC Exam

39. Given the following plant conditions:

- Power is 100% RTP

- Annunciator APP-009-B8, 480V NORM BUS OVLD is received

- Annunciator APP-009-E7, 480V GRD FAULT is received Subsequently:

- The Field AO reports that the following breakers have TRIPPED and are OPEN:

- 52/15B, MAIN BKR. 480V BUS 3

- 52/14A, B ROD DRIVE MG

- In addition, the Field AO reports that the 480V Bus 3 GROUND FAULT RELAY FLAG has actuated.

Which ONE(1) of the following completes the statement below?

Based on the above conditions, receipt of annunciator APP-005-E6, ROD CONT MG SETS TRIPPED ____(1)____ expected. Upon the tripping of breaker 52/15B the ground fault condition cleared. With no further operator action APP-009-E7 will

____(2)____ extinguish.

A. (1) is (2) Automatically B. (1) is (2) NOT C. (1) is NOT (2) Automatically D. (1) is NOT (2) NOT Tuesday, September 23, 2014 11:14:21 AM 38

ILC-14 RO NRC Exam

40. Given the following plant conditions:

- The unit is operating at 100% power.

- PZR Pressure channel PT-455, PZR PRESSURE PROTECTION CHANNEL I, is failed, with all bistables in the TRIPPED condition.

- A subsequent electrical fault results in loss of Instrument Bus 3.

Which ONE(1) of the following completes the statement below?

Which ONE (1) of the following describes the impact that the loss of Instrument Bus 3 has on the plant? A reactor trip occurs, ________.

A. but NO Sl occurs B. and an SI occurs, but ONLY Train 'A' Engineered Safeguards loads are automatically started by the sequencers C. and an Sl occurs, but ONLY Train 'B' Engineered Safeguards loads are automatically started by the sequencers D. and an Sl occurs, with BOTH trains of Engineered Safeguards loads automatically started by the sequencers Tuesday, September 23, 2014 11:14:21 AM 39

ILC-14 RO NRC Exam

41. Given the following plant conditions:

0400:

- The unit is at 100% RTP

- Containment Air Recirculation Cooling units HVH-2, HVH-3, and HVH-4 are in operation

- Containment Air Recirculation Cooling unit HVH-1 has been stopped for breaker maintenance that will be performed on the next shift 0500:

- A large break LOCA has occurred

- SI has actuated 0510:

- The SI signal has been reset Which ONE(1) of the following completes the statement below?

At 0515, the normal air inlet damper for HVH-1 is __(1)__ and the status of HVH-2 fan is __(2)___ .

A. (1) closed (2) off B. (1) closed (2) on C. (1) open (2) off D. (1) open (2) on Tuesday, September 23, 2014 11:14:21 AM 40

ILC-14 RO NRC Exam

42. Given the following plant conditions:

- The unit tripped from 100% power with the following conditions:

- The Crew is in EOP-E-1, LOSS OF REACTOR OR SECONDARY COOLANT, with a Safety Injection in progress due to a Large Break LOCA

- Containment pressure peaked at 15 psig and currently is 6 psig and lowering slowly

-The following annunciators are in alarm:

- APP-002-F2 SPRAY ADD TANK LO LEVEL

- APP-002-A3 RWST HI/LO LVL

-Spray additive tank level is 10% and lowering slowly Which ONE(1) of the following completes the statement below?

The operators will close CV spray additive tank discharge valves, SI-845A and SI-845B ___(1)____ and go to EPP-9, TRANSFER TO COLD LEG RECIRCULATION (2) .

A. (1) at this time (2) when alarm APP-002-B3 RWST LO-LO LVL actuates B. (1) at this time (2) at this time C. (1) when containment pressure is less than 4 psig (2) when alarm APP-002-B3 RWST LO-LO LVL actuates D. (1) when containment pressure is less than 4 psig (2) at this time Tuesday, September 23, 2014 11:14:21 AM 41

ILC-14 RO NRC Exam

43. Given the following plant conditions:

- A loss of offsite power and a reactor trip has occurred

- APP-007-F5, SD AFW PMP LO DISCH PRESS TRIP alarms and remains locked in

- Two minutes later the pump has been verified to be coasting down locally due to an overspeed trip Which ONE(1) of the following completes the statements below?

SDAFW Pump Steam Shutoff Valves, V1-8A, V1-8B, and V1-8C should be (1) at this time. The BOP operator is required to (2) closure of SDAFW Pump Discharge Valves, V2-14A, V2-14B, and V2-14C.

A. (1) open (2) verify automatic B. (1) open (2) perform manual C. (1) closed (2) verify automatic D. (1) closed (2) perform manual Tuesday, September 23, 2014 11:14:21 AM 42

ILC-14 RO NRC Exam

44. Given the following plant conditions:

- Reactor power is at 62% RTP

- S/G "C" water level is stable at 52%

- FCV-498, S/G C FWRV has been placed in local-handwheel control in accordance with OP-403, FEEDWATER SYSTEM for level control circuit maintenance

- Field personnel have reached OP-403 step 8.4.3.2.n, INITIATE the required maintenance activities.

Subsequently:

- I&C Maintenance reports that, locally, the FCV-498 Bailey Positioner has failed and is out-putting a max signal Which ONE(1) of the following completes the statement below?

Based on the above conditions, FCV-498 ____(1)____ reposition.

Should MFP A trip during the above conditions, AOP-010, MAIN FEEDWATER/CONDENSATE MALFUNCTION will direct Operators to ____(2)____ .

A. (1) will (2) perform a Reactor Trip B. (1) will (2) stabilize reactor power <60%

C. (1) will NOT (2) perform a Reactor Trip D. (1) will NOT (2) stabilize reactor power <60%

Tuesday, September 23, 2014 11:14:21 AM 43

ILC-14 RO NRC Exam

45. Given the following plant conditions:

- The CST has developed a leak

- The reactor is in Mode 1; Mode 3 preparations are currently in progress Which ONE(1) of the following completes the statement below?

OP-402, AUXILIARY FEEDWATER SYSTEM states that once CST level is below

___(1)___ %, the ___(2)___ Driven AFW pump(s) require(s) venting prior to use, if not already in operation.

A. (1) 10 (2) Motor B. (1) 10 (2) Steam C. (1) 34 (2) Motor D. (1) 34 (2) Steam

46. Which ONE(1) of the following completes the statement below?

Emergency Diesel Generator (EDG) amperage shall NOT exceed (1) amps, to prevent exceeding the current rating of the (2) .

A. (1) 3200 (2) EDG output breaker B. (1) 3200 (2) generator stator windings C. (1) 4000 (2) EDG output breaker D. (1) 4000 (2) generator stator windings Tuesday, September 23, 2014 11:14:21 AM 44

ILC-14 RO NRC Exam

47. Given the following plant conditions:

- The plant is at 100% power, steady-state

- A fault in the 230kV switchyard sends trip-open signals to generator output breakers 52/8 & 52/9

- Breaker 52/8 fails to open Which ONE(1) of the following completes the statement below?

Generator lockout relay(s) (1) will actuate directly from 52/8 failure to open (do not infer later signals that may actuate either or both lockout relays).

Following the Fast Bus Transfer, if the lockout relay(s) is/are reset with the 52/8 failure-to-open signal still present, (2) .

A. (1) 86P AND 86BU (2) one or more 4kV bus supply or tie breakers will reposition B. (1) 86P AND 86BU (2) there will be no effect on 4kV bus alignment C. (1) ONLY 86P (2) one or more 4kV bus supply or tie breakers will reposition D. (1) ONLY 86P (2) there will be no effect on 4kV bus alignment Tuesday, September 23, 2014 11:14:21 AM 45

ILC-14 RO NRC Exam

48. Given the following plant conditions:

- A Loss of Offsite Power has occurred

- BOTH EDGs have failed to auto start and cannot be manually started

- EPP-1, LOSS OF ALL AC POWER, has been implemented Which ONE(1) of the following completes the statement below?

In accordance with EPP-1, low priority loads __(1)___ required to be shed from Instrument Buses 2 and 3 to minimize the discharge rate of station batteries.

Assuming battery load remains constant, battery current will __(2)__ as terminal voltage lowers.

A. (1) are (2) rise B. (1) are (2) lower C. (1) are NOT (2) rise D. (1) are NOT (2) lower Tuesday, September 23, 2014 11:14:21 AM 46

ILC-14 RO NRC Exam

49. Which ONE(1) of the following completes the statement below?

EDG A auto started and loaded due to a Loss of Offsite Power. The DG speed control __ (1)_ aligned with 0% percent droop.

Following the Blackout Sequencer loading, the 480 Emergency Bus E-1 frequency indicates 58.9 Hz. With no additional action, the speed of DG A (2) be adjusted from the Generator Control Panel using the EDG A Speed Control Switch in accordance with OP-604.

A. (1) is (2) can B. (1) is (2) can NOT C. (1) is NOT (2) can D. (1) is NOT (2) can NOT Tuesday, September 23, 2014 11:14:21 AM 47

ILC-14 RO NRC Exam

50. Given the following plant conditions:

- The unit has entered EPP-1, Loss of All AC Power

- EDG A is unavailable due to maintenance

- EDG B failed to start

- The Inside AO was dispatched to locally start the B EDG

- EDG B LOCAL-REMOTE switch was placed in the LOCAL position at the DG Engine Control Panel Which ONE(1) of the following completes the statement below?

When the AO depresses the Local Engine Start pushbutton, the engine ___(1)___

automatically prelube.

Assuming the EDG B is successfully started and the LOCAL-REMOTE switch remains in the LOCAL position, the EDG B output breaker 52/27B ___(2)___ be closed from the RTGB.

A. (1) will (2) can B. (1) will (2) can NOT C. (1) will NOT (2) can D. (1) will NOT (2) can NOT Tuesday, September 23, 2014 11:14:21 AM 48

ILC-14 RO NRC Exam

51. Given the following plant conditions:

- The plant is operating at 100% RTP

- A release of Waste Condensate Tank (WCT) "A" is in progress

- APP-036-E7, RAD MONITOR TROUBLE, is received

- BOP reports the FAIL light for R-18, LIQUID WASTE DISPOSAL EFFLUENT monitor, is ON Which ONE (1) of the following describes the status of RCV-018, LIQUID WASTE RELEASE ISOLATION VALVE?

RCV-018 will...

A. NOT automatically close. The release must be terminated manually B. automatically close when the monitor FAIL light is illuminated C. NOT automatically close, and CANNOT be closed from the Waste Disposal Panel D. automatically close, and must be reset by cycling the valves pneumatic controller

52. Given the following plant conditions:

- Operating at 100% power

- EDG "B" is unavailable due to emergent maintenance

- All other systems are in their normal at power configuration

- The SU TRANSF OVLD/ PHASE TRIP alarm energizes due to an overload of breaker 52/17, Start-Up Transformer to 4KV Bus 3.

Thirty seconds after the above alarm is received, which of the following CCW pumps can be manually started from the main control room?

A. CCW "A" pump only B. CCW "B" pump only C. CCW "C" pump only D. CCW pumps "A" & "B" Tuesday, September 23, 2014 11:14:21 AM 49

ILC-14 RO NRC Exam

53. Which one of the following completes the statements below regarding the design of the MSIV accumulators?

MSIV accumulators are designed to maintain a minimum of 58 psig for at least ____(1)____ minutes. Nitrogen ____(2)____ be aligned as a backup motive force for the MSIVs.

A. (1) 15 (2) can NOT B. (1) 30 (2) can NOT C. (1) 15 (2) can D. (1) 30 (2) can Tuesday, September 23, 2014 11:14:21 AM 50

ILC-14 RO NRC Exam

54. Given the following plant conditions:

- The plant was operating at 100% power

- A catastrophic failure of Instrument Air header piping occurred

- IA header pressure is 5 psig and lowering

- APP-001-C1, RCP THERM BAR COOL WTR HI FLOW, is in alarm

- APP-001-D1, RCP THERM BAR COOL WTR LO FLOW, is in alarm

- Operators are concurrently executing AOP-017, LOSS OF INSTRUMENT AIR and EOP-E-0, REACTOR TRIP OR SAFETY INJECTION

- ONLY Charging pump "A" is running at minimum speed per AOP-017 Which ONE(1) of the following completes the statement below?

LCV-115A, VCT/HI DP TK DIV, will fail to the ____(1)____.

Consider separately:

With the instrument air header depressurized, in order to raise RCP seal injection flow per Section B of AOP-017, you shall ____(2)____.

A. (1) CVCS Hold Up Tank (2) throttle closed charging flow valve (HCV-121) from the Main Control Room B. (1) CVCS Hold Up Tank (2) locally throttle RCP seal water flow control valves C. (1) VCT (2) throttle closed charging flow valve (HCV-121) from the Main Control Room D. (1) VCT (2) locally throttle RCP seal water flow control valves Tuesday, September 23, 2014 11:14:21 AM 51

ILC-14 RO NRC Exam

55. Which one of the following describes a correct configuration for the Containment Main Personnel Access Hatch doors and equalizing valves while the airlock is in use for entering/exiting Containment while the plant is in MODE 1?

A. Outer door OPEN Outer door equalizing valve OPEN Inner door CLOSED Inner door equalizing valve CLOSED B. Outer door OPEN Outer door equalizing valve OPEN Inner door CLOSED Inner door equalizing valve OPEN C. Outer door CLOSED Outer door equalizing valve OPEN Inner door OPEN Inner door equalizing valve CLOSED D. Outer door CLOSED Outer door equalizing valve CLOSED Inner door OPEN Inner door equalizing valve CLOSED Tuesday, September 23, 2014 11:14:21 AM 52

ILC-14 RO NRC Exam

56. Given the following plant conditions:

- A Reactor trip coincident with a Loss of Offsite Power has occurred

- RVLIS has lost indication Which ONE(1) of the following completes the statements below?

IAW EPP-6, the crew will cool down from 500°F to 450°F at (1) °F/hr. During the FIRST depressurization, the crew will depressurize to (2) psig.

A. (1) 100 (2) 1600 B. (1) 50 (2) 1600 C. (1) 100 (2) 800 D. (1) 50 (2) 800

57. The Unit is commencing a Reactor Start Up and is pulling control groups A and B rods. At 25 steps on the B bank an IRPI module for a B group rod fails low.

Which ONE(1) of the following completes the statement below?

Annunciator APP-005-F2 ROD BOTTOM, ROD DROP (1) be ILLUMINATED and an ERFIS printout for Rod Deviation (2)___ occur.

A. (1) will (2) will B. (1) will (2) will NOT C. (1) will NOT (2) will D. (1) will NOT (2) will NOT Tuesday, September 23, 2014 11:14:21 AM 53

ILC-14 RO NRC Exam

58. Given the following plant conditions:

A Loss of Coolant Accident (LOCA) has been in progress for the last two hours. You have been assigned to monitor plant parameters as indicated on the Main Control Room ICCM plasma displays.

Both Train A and B ICCM plasma displays contain the exact SAME indications.

- FULL RANGE RVLIS 100%

- SUBCOOL (T/C) 34oF

- AVG 5 HIGH 605oF

- SUBCOOL (RTD) 37oF

- HIGH RTD 607oF Operators are MANUALLY monitoring the CSF-2, Core Cooling Critical Safety Function Status Tree and have reached the RCS Subcooling Decision Block.

Which ONE(1) of the following completes the statement below?

In accordance with OMM-022, EMERGENCY OPERATING PROCEDURES USERS GUIDE and based on the conditions above, CSFST parameter monitoring

____(1)____ be relaxed to 10-20 minutes.

When monitoring for the RCS Subcooling Decision Block, the ICCM plasma display value of ____(2)____ should be used per OMM-022.

A. (1) may (2) SUBCOOL (T/C)

B. (1) may (2) SUBCOOL (RTD)

C. (1) may NOT (2) SUBCOOL (T/C)

D. (1) may NOT (2) SUBCOOL (RTD)

Tuesday, September 23, 2014 11:14:21 AM 54

ILC-14 RO NRC Exam

59. Which ONE (1) of the following is the power supply for HVE-3, CV Air Iodine Removal Fan?

A. MCC-5 B. MCC-6 C. MCC-9 D. MCC-10

60. Given the following plant conditions:

- Containment particulate and gas monitors R-11 and R-12 are in service

- Containment Purge fan HVE-1A is running Which ONE(1) of the following completes the statement below?

If purge fan HVE-1A loses power ___(1)____.

Subsequently:

- R-11 alarmed and is now reading below the alarm setpoint After resetting the R-11 alarm, manual operation of containment purge inlet and outlet valves (2) be performed.

A. (1) all containment purge inlet and outlet valves will automatically close (2) can B. (1) all containment purge inlet and outlet valves will automatically close (2) can NOT C. (1) containment purge fan HVE-1B will automatically start (2) can D. (1) containment purge fan HVE-1B will automatically start (2) can NOT Tuesday, September 23, 2014 11:14:21 AM 55

ILC-14 RO NRC Exam

61. Given the following plant conditions:

- Boron concentrations in the Spent Fuel Pit (SFP) have just been analyzed to be 1483 ppm.

- The Shift Manager determines that OP-910, SPENT FUEL PIT COOLING AND PURIFICATION SYSTEM, Section 8.4.6 will be used by conservatively applying the note in that procedure to raise boron concentration.

- NOTE: Each 100 pound bag of granulated boric acid will raise SFP boron concentration by 6 ppm.

Which ONE(1) of the following completes the statement below?

Based on the information above and the NOTE provided, the MINIMUM number of bags of granulated boric acid needed to raise the SFP boron concentration to the MINIMUM Tech Spec limit is (1) bags.

Based on the information above and the NOTE provided, the MINIMUM number of bags of granulated boric acid needed to raise the SFP boron concentration to the MINIMUM Administrative limit of OP-910 is (2) bags.

A. (1) 3 (2) 95 B. (1) 78 (2) 95 C. (1) 3 (2) 153 D. (1) 78 (2) 153 Tuesday, September 23, 2014 11:14:21 AM 56

ILC-14 RO NRC Exam

62. Given the following plant conditions:

- Unit 2 is in Mode 6 and refueling activities are in progress with the equipment hatch REMOVED

- R-14C, Plant Vent Low Range Noble Gas Monitor is out of service

- A fuel assembly has been visibly damaged during removal from the core

- AOP-013, "Fuel Handling Accident", is in progress R-2, CV area rad monitor R-12, CV Air & Plant Vent Radioactive Gas Which ONE(1) of the following completes the statement below?

Radiation Monitor ___(1)____ would provide the FIRST indications in the control room of a developing leak from the damaged fuel assembly. Once the Rad Monitor is in ALARM, IAW AOP-013, the containment purge system is verified ___(2)___ service.

A. (1) R-2 (2) in B. (1) R-2 (2) NOT in C. (1) R-12 (2) in D. (1) R-12 (2) NOT in Tuesday, September 23, 2014 11:14:21 AM 57

ILC-14 RO NRC Exam

63. Given the following plant conditions:

- A startup following a refueling outage is in progress with the reactor at 25%

power and stable, holding for Chemistry with the following conditions:

- Rod control is in AUTO

- All other systems are in automatic A 100 MWe load rejection occurs. Which one of the following describes the OVERALL response and final condition for Steam Generator water level?

With no operator action, NR S/G water levels will _______ .

A. lower, then return to original level B. rise, then return to original level C. rise, then stabilize at a level lower than the original level D. lower, then stabilize at a level lower than the original level Tuesday, September 23, 2014 11:14:21 AM 58

ILC-14 RO NRC Exam

64. Given the following plant conditions:

Which of the following correctly completes the following statements in accordance with OP-704, Spent Resin Storage Tank, for transferring spent resin from the Spent Resin Storage Tank (SRST) to a High Integrity Container (HIC)?

Which ONE (1) of the following completes the statements below to minimize radiation exposure to site personnel:

The method used to warn personnel of the radiological hazard is/are (1) .

A flush of the transfer lines__(2)___ required after resin transfer.

A. (1) gates with signs and alarms posted at all doors to the auxiliary building and radwaste building (2) is B. (1) gates with signs and alarms posted at all doors to the auxiliary building and radwaste building (2) is NOT C. (1) a PA announcement made to warn unnecessary personel to stay clear (2) is D. (1) a PA announcement made to warn unnecessary personel to stay clear (2) is NOT Tuesday, September 23, 2014 11:14:21 AM 59

ILC-14 RO NRC Exam

65. Given the following plant conditions:

- The plant is operating at 100% RTP

- The instrument air / station air cross connect bypass filter inlet and outlet valves are tagged out for filter replacement

- A loss of Instrument Air has occurred with pressure currently at 75 psig

- The crew is implementing AOP-017, LOSS OF INSTRUMENT AIR SA-70, PRIMARY AIR COMP RECEIVER TO STATION AIR HEADER SA-5, STATION AIR TO INST AIR CROSS CONNECT Which ONE(1) of the following completes the statement below?

As pressure lowered, at (1) psig Instrument Air header pressure, AOP-017 directed an operator to be dispatched to (2) .

A. (1) 85 (2) open SA-70 B. (1) 80 (2) open SA-70 C. (1) 85 (2) open SA-5 D. (1) 80 (2) open SA-5 Tuesday, September 23, 2014 11:14:21 AM 60

ILC-14 RO NRC Exam

66. Which ONE(1) of the following completes the statements below?

IAW OMM-001-2, SHIFT ROUTINES AND OPERATING PRACTICES, the MINIMUM number of personnel that are reserved for fire response is (1) .

The MINIMUM number of SROs required for safe shutdown activities when implementing DSP-002, HOT SHUTDOWN USING THE DEDICATED/ALTERNATE SHUTDOWN SYSTEM, is (2) .

A. (1) 7 (2) 1 B. (1) 7 (2) 2 C. (1) 5 (2) 1 D. (1) 5 (2) 2

67. Which one of the following includes acceptance criteria for the ECCS following a postulated Loss-of-Coolant Accident, as required by 10 CFR 50.46, "Acceptance criteria for emergency core cooling systems for light-water nuclear reactors?"

The calculated maximum fuel element cladding temperature shall be maintained less than ___(1)___ degrees F and the maximum cladding oxidation less than ___(2)___

percent.

A. (1) 2200 (2) 1 B. (1) 2200 (2) 17 C. (1) 2500 (2) 1 D. (1) 2500 (2) 17 Tuesday, September 23, 2014 11:14:21 AM 61

ILC-14 RO NRC Exam

68. The operating crew is performing actions to place the plant in Mode 5 in accordance with GP-007, PLANT COOLDOWN FROM HOT SHUTDOWN TO COLD SHUTDOWN with the following sequence of events:

- 0830 MDAFW Pump "B" placed in service

- 1430 MDAFW Pump "B" secured

- 1432 RHR Pump "A" placed in service

- 1448 RHR Pump "A" secured due to a flow indication problem on FI-608

- 1458 RHR Pump "A" placed in service

- 1505 RHR Pump "A" secured due to a flow indication problem on FI-608

- 1509 RHR Pump "A" placed in service

- 1525 RHR Pump "A" secured due to a flow indication problem on FI-608 FI-608, RHR SYSTEM HEATUP LINE FLOW INDICATION The time is currently 1530 Which ONE(1) of the following completes the statement below?

The maximum number of consecutive pump starts available for MDAFW Pump "B" in accordance with OP-402, AUXILIARY FEEDWATER SYSTEM is __(1)__ .

A 45 minute waiting period prior to restarting RHR Pump "A" __(2)__ required in accordance with OP-201, RESIDUAL HEAT REMOVAL SYSTEM.

A. (1) 2 (2) is B. (1) 2 (2) is NOT C. (1) 3 (2) is D. (1) 3 (2) is NOT Tuesday, September 23, 2014 11:14:21 AM 62

ILC-14 RO NRC Exam

69. Given the following plant conditions:

- The plant is at 100% power

- A malfunction in LC-459G, PRESSURIZER LEVEL, has caused PZR level to increase to 64% over the last 10 minutes. The controller remains in AUTO, with no operator action

- Pressurizer heaters and sprays over-compensated for the rising pressure caused by rising level, and stabilized PZR pressure at 2225 psig by the lowest indicator

- All other RCS parameters are within their normal control bands The Reactor Operator should notify the CRS that:

A. the reactor should be tripped because a trip setpoint will be reached within the next 2 minutes B. an entry condition for ITS 3.4.9, Pressurizer, has been met C. an entry condition for ITS 3.4.1, RCS Pressure, Temperature, and Flow Departure from Nucleate Boiling (DNB) Limits, has been met D. entry into AOP-025, RTGB Instrument Failure, is required

70. Which ONE(1) of the following completes the statement below?

A release of a Waste Gas Decay Tank ___(1)___ allowed while simultaneously releasing the containment via a continuous CV purge.

A release of a Waste Gas Decay Tank is allowed while stack monitor R-14C is out of service ___(2)___ .

A. (1) is (2) as long as R-14D is operable because the ranges overlap B. (1) is NOT (2) as long as R-14D is operable because the ranges overlap C. (1) is (2) as long as an independent sample of the tank to be released has been performed D. (1) is NOT (2) as long as an independent sample of the tank to be released has been performed Tuesday, September 23, 2014 11:14:21 AM 63

ILC-14 RO NRC Exam

71. Given the following plant conditions:

- SBLOCA is in progress

- CV Ventilation Isolation valves did not close EOP-E-0: REACTOR TRIP OR SAFETY INJECTION Which ONE(1) of the following completes the statements below?

IAW EOP-E-0 Attachment 1, Auto Action Verification, the crew will depress the (1) push button on R-11 or R-12 to initiate the automatic actions that should have occurred.

Once the automatic actions have occurred, the R-11/R-12 vacuum pump (2) have to be secured.

A. (1) H.V. OFF (2) will B. (1) H.V. OFF (2) will NOT C. (1) Alarm/Reset (2) will D. (1) Alarm/Reset (2) will NOT Tuesday, September 23, 2014 11:14:21 AM 64

ILC-14 RO NRC Exam

72. Given the following conditions:

- While entering the plant to relieve the shift, you notice smoke coming from the Reactor Auxiliary Building.

- You have NOT logged onto any RWP or obtained proper dosimetry (EAD).

- Your assistance is required in the Auxiliary Building.

Which one of the following is allowed/required IAW FP-001, FIRE EMERGENCY for the stated conditions?

A. An exception to the requirement for an EAD AND RWP login is allowed for qualified members of the Fire Brigade (No RC Tech is required to invoke the exception).

B. An EAD must be obtained AND RWP login must be completed prior to Auxiliary Building entry.

C. An exception to the requirement for obtaining an EAD AND RWP login is allowed ONLY IF an RC Tech is present to monitor personnel entry/exit to the Auxiliary Building.

D. RWP login is NOT required, and emergency dosimetry (EAD) is obtained from the RCA entrance.

Tuesday, September 23, 2014 11:14:21 AM 65

ILC-14 RO NRC Exam

73. Given the following plant conditions:

- A reactor shutdown is in progress in accordance with GP-006-1, NORMAL PLANT SHUTDOWN FROM POWER OPERATION

- Reactor Power is 3%

- The Main Turbine has been shutdown

- The electric plant is in a normal shutdown alignment with buses supplied from the SUT Subsequently:

- Operators have depressed both Reactor Trip pushbuttons in accordance with GP-006-1

- Reactor Trip breakers remain CLOSED

- Intermediate Range SUR indication is fluctuating between 0.1 and -0.1 DPM EOP-E-0, REACTOR TRIP OR SAFETY INJECTION FRP-S.1, RESPONSE TO NUCLEAR POWER GENERATION/ATWS Which answer below describes the required crew response to the above conditions?

A. Enter EOP-E-0, do NOT enter FRP-S.1 B. Enter FRP-S.1, do NOT enter EOP-E-0 C. Enter EOP-E-0 AND FRP-S.1 D. Do NOT enter EOP-E-0 OR FRP-S.1 Tuesday, September 23, 2014 11:14:21 AM 66

ILC-14 RO NRC Exam

74. Given the following plant conditions:

- The plant is at 100% power

- Control Room receives APP-036-H5, ANNUN SYS DC PWR LOST

- The plant remains stable Which ONE(1) of the following completes the statement below?

As Balance of Plant Operator, you direct the Turbine Building Auxiliary Operator to check Breaker 10, Annunciator Panel (RTGB), on Distribution Panel (1) .

Per OP-603, Electrical Distribution, Precautions & Limitations, if there is no evidence of abnormality present, the breaker can be reset (2) .

A. (1) A (2) one time B. (1) B (2) only after consultation with Engineering C. (1) A (2) only after consultation with Engineering D. (1) B (2) one time Tuesday, September 23, 2014 11:14:21 AM 67

ILC-14 RO NRC Exam

75. Given the following plant conditions:

- The unit is operating at 100% power

- Grid frequency is beginning to lower Which ONE(1) of the following completes the statement below?

The highest frequency, below which entry into AOP-026 (Grid Instability) will be required, is (1) Hz.

The highest frequency, below which an automatic Reactor trip will occur, is (2) Hz.

A. (1) 59.8 (2) 58.2 B. (1) 59.8 (2) 58.4 C. (1) 59.0 (2) 58.2 D. (1) 59.0 (2) 58.4 You have completed the test!

Tuesday, September 23, 2014 11:14:21 AM 68

ANSWER KEY REPORT for ILC-14 RO NRC Exam Test Form: 0 Answers

  1. ID Points Type 0 1 007 EA1.03 1 1.00 MCS B 2 008 AK2.03 1 1.00 MCS C 3 009 EK2.03 1 1.00 MCS B 4 011 EG2.4.21 1 1.00 MCS C 5 022 AA1.09 1 1.00 MCS B 6 025 AA2.07 1 1.00 MCS B 7 026 AK3.03 1 1.00 MCS D 8 027 AG2.4.49 1 1.00 MCS A 9 029 EG2.4.31 1 1.00 MCS C 10 038 EA1.10 1 1.00 MCS C 11 040 AK3.04 1 1.00 MCS A 12 054 AA2.03 1 1.00 MCS B 13 055 EK1.02 1 1.00 MCS C 14 056 AK1.04 1 1.00 MCS B 15 057 AK3.01 1 1.00 MCS D 16 065 AA2.06 1 1.00 MCS B 17 W/E 04 EK2.2 1 1.00 MCS A 18 W/E 05 EK1.3 1 1.00 MCS D 19 003 AK3.05 1 1.00 MCS D 20 005 AG2.1.28 1 1.00 MCS A 21 024 AA2.02 1 1.00 MCS A 22 028 AA1.02 1 1.00 MCS C 23 032 AK1.01 1 1.00 MCS C 24 033 AA2.09 1 1.00 MCS A 25 061 AA1.01 1 1.00 MCS B 26 067 AK3.02 1 1.00 MCS C 27 W/E 09 EK2.2 1 1.00 MCS C 28 003 K5.04 1 1.00 MCS D 29 003 K6.04 1 1.00 MCS B 30 004 K3.06 1 1.00 MCS C 31 005 K4.12 1 1.00 MCS C 32 005 K5.05 1 1.00 MCS A 33 006 A4.02 1 1.00 MCS C 34 007 K5.02 1 1.00 MCS C 35 008 A1.02 1 1.00 MCS D 36 008 K3.03 1 1.00 MCS C 37 010 K1.08 1 1.00 MCS B 38 012 A2.03 1 1.00 MCS B 39 012 A4.07 1 1.00 MCS B 40 013 K2.01 1 1.00 MCS B 41 022 A3.01 1 1.00 MCS B 42 026 G2.1.31 1 1.00 MCS D 43 039 A4.04 1 1.00 MCS D 44 059 A2.12 1 1.00 MCS D 45 061 K6.02 1 1.00 MCS D 46 062 A1.01 1 1.00 MCS C 47 062 K1.04 1 1.00 MCS B Tuesday, September 23, 2014 11:15:05 AM 1

ANSWER KEY REPORT for ILC-14 RO NRC Exam Test Form: 0 Answers

  1. ID Points Type 0 48 063 A1.01 1 1.00 MCS A 49 064 A3.13 1 1.00 MCS A 50 064 G2.4.35 1 1.00 MCS C 51 073 K4.01 1 1.00 MCS A 52 076 K2.04 1 1.00 MCS B 53 078 K1.05 1 1.00 MCS B 54 078 K3.02 1 1.00 MCS D 55 103 K4.04 1 1.00 MCS A 56 002 K6.03 1 1.00 MCS A 57 014 K3.02 1 1.00 MCS C 58 017 A2.02 1 1.00 MCS A 59 027 K2.01 1 1.00 MCS A 60 029 K4.02 1 1.00 MCS D 61 033 G2.1.25 1 1.00 MCS A 62 034 A4.01 1 1.00 MCS C 63 035 A3.01 1 1.00 MCS D 64 068 K5.04 1 1.00 MCS C 65 079 K1.01 1 1.00 MCS D 66 G 2.1.1 1 1.00 MCS C 67 G 2.1.27 1 1.00 MCS B 68 G 2.2.2 1 1.00 MCS D 69 G 2.2.42 1 1.00 MCS B 70 G 2.3.11 1 1.00 MCS C 71 G 2.3.5 1 1.00 MCS A 72 G 2.3.7 1 1.00 MCS B 73 G 2.4.1 1 1.00 MCS C 74 G 2.4.32 1 1.00 MCS D 75 G 2.4.4 1 1.00 MCS A SECTION 1 ( 75 items) 75.00 Tuesday, September 23, 2014 11:15:05 AM 2