05000261/17301 as Given RO Written Exam with References and Key - Delay Release 2 Yrs
ML17354B267
Person / Time
Site: Robinson 
Issue date: 12/20/2017
From:
NRC/RGN-II
To:
References
50-261/17-301
Download: ML17354B267 (81)


See also: IR 05000261/2017301

Text

Robinson Nuclear Plant

ILC-i 7 RNP RO NRC Examination

Question:

I

(1 point)

Given the following:

The plant is at 100% RTP

At TIME0, an inadvertent turbine trip occurs

At TIME=2 minutes, Intermediate Range N-35 indicates 5.0 E-7 AMPS

Which ONE of the following is the MINIMUM additional time expected for the POWER

ABOVE PERMISSIVE P6 status light to EXTINGUISH on the lR N-35 Drawer?

A.

8lOminutes

B.

11l3minutes

C.

14l6minutes

D.

17l9minutes

Page 1 of 75

Robinson Nuclear Plant

ILC-i 7 RNP RO NRC Examination

Question:

2

(1 point)

Given the following:

RCS Temperature: 170°F and stable

RCS Pressure: 350 psig and stable

Subsequently PT-501, PZR PRESSURE, fails, due to a loss of electrical power.

Which ONE of the following correctly completes the statement below?

lAW AOP-020, LOSS OF RESIDUAL HEAT REMOVAL (SHUTDOWN COOLING) the

OATC is FIRST required to

A.

close PCV-455C, PZR PORV

B.

close RC-536, PORV BLOCK VALVE

C.

place the associated LTOPP Arming Switch to the NORMAL position

D.

take Manual Control of PC-444J, PZR PRESS and restore RCS pressure to

350 psig

Page 2 of 75

Robinson Nuclear Plant

ILC-1 7 RNP RO NRC Examination

Question:

3

(1 point)

Given the following:

The crew is performing EQP-ES-i .2, POST LOCA COOLDOWN AND

DEPRESS U R IZATI ON

All reactor coolant pumps have been stopped

SIG narrow range levels are 30% and stable

Which ONE of the following correctly completes the statements below?

While Natural Circulation is occurring

(1)

will be at or trending to saturation

temperature for the associated steam generator pressure.

If the RCS level lowers to the point that steam voiding has begun to occur in the RCS

hot legs, the steam generators will

f2)

A.

(l)Thot

(2) stop removing heat due to the interruption of natural circulation flow

B.

(i)Tc01d

(2) stop removing heat due to the interruption of natural circulation flow

C.

(I) hot

(2) continue removing heat by reflux boiling

D.

(i)T0iu

(2) continue removing heat by reflux boiling

Page 3 of 75

Robinson Nuclear Plant

ILC-1 7 RNP RO NRC Exctmination

Question:

4

(1 point)

Given the following:

EOP-E-1, LOSS OF REACTOR OR SECONDARY COOLANT is being performed

CV Pressure is 12 psig, slowly rising

RTGB Annunciator APP-002-E1, CV SRY PMP COOL WTR LO FLOW, alarms

Which ONE of the following correctly completes the statements below?

lAW APP-002-E1, the control room

(II

required dispatch an operator to

locally check flow on FIC-657,CCW SPRAY PMP FLOW IND & LO ALARM.

The CV spray pumps

(2)

required to be stopped immediately.

A.

(1) is

(2) are

B.

(1) is

(2) are NOT

C.

(1)isNOT

(2) are

D.

(1)isNOT

(2) are NOT

Page 4 of 75

Question:

5

(1 point)

Robinson Nuclear Plant

ILC-i 7 RNP RO NRC Examination

Given the following:

The plant is at 25% RTP, returning to power following a trip

APP-036-D8, PROCESS MONITOR HI RAD is received

The OATC observes the following:

The OATC is required to,

(2)

AOP-014, COMPONENT COOLING WATER SYSTEM MALFUNCTION

AOP-018, REACTOR COOLANT PUMP ABNORMAL CONDITIONS

A.

(1) #1 Seal failure has occurred

(2) lAW AOP-018, determine total affected RCP #1 Seal leakoff flow rate,

before taking further action

B.

(1) #1 Seal failure has occurred

(2) lAW AOP-O1 8, trip the reactor, then trip the affected RCP and go to EOP-E

0, REACTOR TRIP OR SAFETY INJECTION

C.

(1) Thermal barrier has a leak

(2) lAW AOP-014, check FCV-626, THERM BAR FLOW CONT valve closed.

If it is not closed, the OATC is required to close FCV-626

D.

(1) Thermal barrier has a leak

(2) lAW AOP-014, check FCV-626, THERM BAR FLOW CONT valve closed.

If it is not closed, the OATC is required to close CC-735, THERM BAR OUT

ISO valve immediately

Which ONE of the following correctly completes the statements below?

RCPB

Li)

Page 5 of 75

Robinson Nuclear Plant

ILC-J7RNPRO NRC Examination

Question:

6

(1 point)

Given the following:

The crew is responding to a loss of charging lAW AOP-003-1

LOSS OF

CHARGING OR LETDOWN, due to NO charging pumps running.

Letdown has been isolated

APP-O01-D1, RCP THERM BAR COOL WTR LO FLOW, is EXTINGUISHED

CCW Heat Exchanger outlet temperature is 104°F

RCP #1 Seal Leakoff flows are approximately 2.5 GPM

Pressurizer level is 37% and slowly lowering

It has been 15 minutes since all Charging has been lost

lAW AOP-003-1 which ONE of the following identifies the NEXT required action, AND

the reason for this action?

A.

Attempt to restore at least one Charging Pump because RCP Thermal Barrier

cooling is sufficient.

B.

Isolate the RCP Seal Injection lines to the RCPs to avoid damage to the RCP

Seals when one Charging Pump is restored.

C.

Trip the Reactor and stop the RCPs because CCW Heat Exchanger outlet

temperature is too high to properly cool the Thermal Barrier.

D.

Trip the Reactor and stop the RCPs because the RCP #1 Seal Flows are

abnormal.

Page 6 of 75

Robinson Nuclear Plant

ILC-i 7 RNP RO NRC Examination

Question:

7

(1 point)

Initial conditions:

RHR Train A is in service

Subsequently, the Instrument Air line to FCV-605, RHR HX BYPASS FLOW, ruptured

causing a total loss of operating air to the valve.

ASSUME NO OPERATOR ACTION

Which ONE of the following correctly completes the statements below?

FCV-605 will fail to the

(II

position.

RHR flow through the RHR Heat Exchangers will

(2)

from steady state to

steady state.

A.

(1) open

(2) remain the same

B.

(1) open

(2) lower

C.

(1) close

(2) rise

D.

(1) close

(2) remain the same

Page 7 of 75

Robinson Nuclear Plant

ILC-1 7 RNP RO NRC Examination

Question:

8

(1 point)

Given the following

The plant is at 100% RTP

RCS pressure is currently 2220 PSIG and RISING

The LOWEST RCS pressure observed by the OATC was 2207 PSIG

The OATC is verifying that PC-444J, MASTER PRESSURE CONTROLLER is

operating properly in AUTO

Which ONE of the following correctly completes the statement below?

Proper operation of PC-444J in AUTO would be represented by the Spray Valves

PCV-455A & PCV-455B

(1)

and Control Group Heaters are

(2)

A.

(1) throttled

(2) at 50% fire

B.

(1) throttled

(2) at 25% fire

C.

(1) CLOSED

(2) at 50% fire

D.

(1) CLOSED

(2) full ON

Page $ of 75

Question:

(1 point)

9

Robinson Nuclear Plant

ILC-1 7 RNP RO NRC Examination

Given the following:

An ATWS has occurred

The BOP manually tripped the turbine

Operators have been dispatched to locally trip the reactor

The OATC is taking immediate action lAW FRP-S.1, RESPONSE TO NUCLEAR POWER

GENERATION

- ATWS and observes:

ROD SPEEcj

I

Which ONE of the following correctly completes the statements below?

The OATC

(1)

required to take further action IMMEDIATELY to insert rods into the

core.

Control rods will insert at the current indicated speed until Tave reaches AT LEAST

(2)

A.

(1) is

(2) 548.6°F

B.

(1) is

(2) 552.6°F

C.

(1)isNOT

(2) 548.6°F

D.

(1)isNOT

(2) 552.6°F

Page 9 of 75

Robinson Nuclear Plant

ILC-1 7 RNP RO NRC Examination

Question:

10

(1 point)

Given the following:

The crew is operating in EOP-E-3, STEAM GENERATOR TUBE RUPTURE

The RCS has been cooled to target temperature

The crew is preparing to initiate an RCS depressurization

Which ONE of the following correctly completes the statements below?

lAW EOP-E-3, the RCS depressurization is initiated in order to

(1)

lAW EOP-E-3, if normal PZR spray is not available, the NEXT RCS depressurization

method to be used is

(2)

A.

(1) refill the Pressurizer, ONLY

(2) Aux Spray

B.

(1) refill the Pressurizer, ONLY

(2) one PZR PORV

C.

(1) refill the Pressurizer AND minimize break flow

(2) one PZR PORV

D.

(1) refill the Pressurizer AND minimize break flow

(2) Aux Spray

Page 10 of 75

Robinson Nuclear Plant

ILC-1 7 RNP RO NRC Examination

Question:

11

(1 point)

Given the following:

The plant is at 100% RTP

A major piping rupture occurs on the 72 steam header

Which ONE of the following correctly completes the statements below?

S/G levels will INITIALLY

(1)

A

Safety Injection will automatically occur.

A.

(1) RISE

(2) High Steam Flow

B.

(1) RISE

(2) High Steam Line Differential Pressure

C.

(1) LOWER

(2) High Steam Flow

D.

(1) LOWER

(2) High Steam Line Differential Pressure

Page 11 of75

Robinson Nuclear Plant

ILC-1 7 RNP RO NRC Excimination

Question:

12

(1 point)

Given the following:

The crew was operating in EOP-ECA-O.2, LOSS OF ALL AC POWER RECOVERY

WITH SI REQUIRED, following an Extended Loss of AC Power (ELAP)

The PEAK CV pressure during the ELAP was 4.5 psig

Current conditions:

The crew has just been directed to reset the Safety Parameter Display System

(SPDS) and initiate monitoring of the Critical Safety Function Status Trees

(CSFSTs)

CURRENT CV pressure is 3.5 psig and slowly lowering

Which ONE of the following correctly completes the statements below based on the

current plant conditions?

ERFIS

(11

use adverse containment setpoints when evaluating the CSFSTs

via SPDS.

lAW OMM-022, EMERGENCY OPERATING PROCEDURES USERS GUIDE,

adverse containment setpoints are

(21

to be used.

A.

(1)does

(2) required

B.

(1)does

(2) NOT required

C.

(1)does NOT

(2) required

D.

(1)does NOT

(2) NOT required

Page 12 of 75

Robinson Nuclear Plant

ILC-1 7 RNP RO NRC Examination

Question:

13

(1 point)

Given the following:

The plant was at 100% RTP

An electrical fault in the 115 KV switchyard causes both East and West 115 KV

Busses to deenergize

Assume NO OPERATOR ACTIONS for the first two minutes of this event.

Which ONE of the following correctly completes the statements below?

A Blackout signal will be sensed on 480V Bus E-2

(1)

The B MDAFW pump will receive an automatic start signal

(2)

seconds

after the loss of 480V Bus E-2.

A.

(1) ONLY

(2) 39.5

B.

(1)ONLY

(2) 49.5

C.

(1) AND 480V Bus E-1

(2) 39.5

D.

(1) AND 480V Bus E-1

(2) 49.5

Page 13 of 75

Robinson Nuclear Plant

ILC-i 7 RNP RO NRC Examination

Question:

14

(1 point)

Given the following:

Battery chargers A and B are in service

Battery chargers A-i and B-i are in standby

12:00 MCC-5 is de-energized

13:01 APP-036-D3, BATT A/B LO VOLT, alarm is illuminated

There are multiple indications of loss of control power to components

At 13:05, MCC-5 is re-energized.

Which ONE of the following correctly completes the statements below?

Battery charger(s)

(1)

will need to be manually restarted.

The Design Basis of the A and B battery chargers is to be able to fully recharge its

associated battery in

hours.

A.

(i)A-i ONLY

(2) 10

B.

(i)A&A-i

(2) 10

C.

(1) A & AI

(2) 24

D.

(i)A-I ONLY

(2) 24

Page 14 of 75

Robinson Nuclear Plant

ILC-i 7 RNP RO NRC Examination

Question:

15

(1 point)

Given the following:

Following a plant trip from 4% power at 1200, the crew has just transitioned out of

EOP-E-0, REACTOR TRIP OR SAFETY INJECTION, into an optimal recovery

procedure.

The following parameters are observed at 1300:

Loop ATcold

445°F

Loop B Tcold

330°F

Loop C Tcold

445°F

RCS pressure

1800 psig

CV pressure

I psig

CV sump level

380 inches

CVrad level

1OR/hr

NRIevel

10%

8%

6%

pressure

1055 psig

1075 psig

1095 psig

Which ONE of the following identifies the HIGHEST priority Functional Response

Procedure whose entry condition has been met?

A.

FRP-J.2, RESPONSE TO CONTAINMENT FLOODING

B.

FRP-J.3, RESPONSE TO HIGH CONTAINMENT RADIATION LEVEL

C.

FRP-P.1, RESPONSE TO IMMINENT PRESSURIZED THERMAL SHOCK

D.

FRP-H.4, RESPONSE TO LOSS OF NORMAL STEAM RELEASE

CAPABILITY

Page 15 of75

Robinson Nuclear Plant

ILC-1 7 RNP RO NRC Examination

Question:

16

(1 point)

Given the following:

The plant is at 25% RTP

APP-009-F8, 4KV BUSES LO FREQ, is in alarm

The crew enters AOP-026, GRID INSTABILITY

Frequency is now at 58.3Hz

Which ONE of the following correctly completes the statements below?

lAW AOP-026, The crew is required to

(1)

trip the reactor.

For the given conditions, the reason for the AOP steps to trip the RCPs is to

(2)

A.

(1) immediately

(2) prevent damage to RCP motor wind ings

B.

(1) direct the load dispatcher to raise frequency, but if not corrected within 5

minutes, then

(2) prevent damage to RCP motor wind ings

C.

(1) immediately

(2) preempt the low frequency automatic RCP trip

D.

(1) direct the load dispatcher to raise frequency, but if not corrected within 5

minutes, then

(2) preempt the low frequency automatic RCP trip

Page 16 of 75

Robinson Nuclear Plant

ILC-i 7 RNP RO NRC Examination

Question:

17

(1 point)

lAW EOP-ECA-1 .2, LOCA OUTSIDE CONTAINMENT, which ONE of the following

correctly completes the statements below?

The crew is required to FIRST close

valves.

The crew is required to monitor for

to determine if the break has been

isolated.

A.

(1) Sl-870 A & B, BIT OUTLET

(2) RVLIS level rising

B.

(1) RHR-744 A & B, RHR RETURN TO COLD LEGS

(2) RVLIS level rising

C.

(1) Sl-870 A & B, BIT OUTLET

(2) RCS pressure rising

D.

(1) RHR-744 A & B, RHR RETURN TO COLD LEGS

(2) RCS pressure rising

Page 17 of 75

Robinson Nuclear Plant

ILC-1 7 RNP RO NRC Examination

Question:

18

(1 point)

Given the following:

The crew is operating in EOP-ECA-1.1, LOSS OF EMERGENCY COOLANT

RECIRCULATION

It has been 15 hours1.736111e-4 days <br />0.00417 hours <br />2.480159e-5 weeks <br />5.7075e-6 months <br /> since the reactor trip

RVLIS Full Range is 80%

RCS subcooling is 600 F

Total SI flow is 650 GPM

The crew is at a step to determine if SI can be terminated

Which ONE of the following correctly completes the statement below?

lAW EOP-ECA-1 .1, the crew is required to...

REFERENCE PROVIDED

A.

maintain 650 GPM SI flow.

B.

reduce SI flow to 115 GPM.

C.

reduce SI flow to 140 GPM.

D.

stop ECCS pumps and establish normal charging flow.

Page 18 of 75

Robinson Nuclear Plant

ILC-1 7 RNP RO NRC Examination

Question:

19

(1 point)

Given the following:

The plant is at 75% RTP

The crew is performing GP-005, POWER OPERATION, raising power to 100%

The OATC withdraws control rods 5 steps for temperature control

When the IN-HOLD-OUT lever is released, it returns to the HOLD position

Outward rod motion CONTINUES

Which ONE of the following correctly completes the statements below?

The Rods Out Motion LightII status (illuminated or extinguished) will be

determined by the

Li)

lAW AOP-001, MALFUNCTION OF REACTOR CONTROL SYSTEM, the NEXT

required action for the OATC is to

(2)

A.

(1) Power Cabinet

(2) trip the reactor and GOTO EOP-E-0, REACTOR TRIP OR SAFETY

INJECTION

B.

(1) Logic Cabinet

(2) place the rod bank selector switch in AUTO to attempt to stop the

continuous rod withdrawal

C.

(1) Power Cabinet

(2) place the rod bank selector switch in AUTO to attempt to stop the

continuous rod withdrawal

D.

(1) Logic Cabinet

(2) trip the reactor and GOTO EOP-E-0, REACTOR TRIP OR SAFETY

INJECTION

Page 19 of75

Robinson Nuclear Plant

ILC-i 7 RNP RO NRC Examination

Question:

20

(1 point)

Given the following:

LT-459, CH

I PRZR LEVEL is selected for control

The REFERENCE LEG for LT-459 develops a slow and small leak

Which ONE of the following correctly identifies the indications the OATC observes at

the RTGB over the first minute of this event?

(ASSUME NO OPERATOR ACTION)

LI-459

LI-460

PZRLVL

PZRLVL

VCT

Indication

Indication

Level

A.

Rises

Lowers

Rises

B.

Lowers

Rises

Rises

C.

Rises

Lowers

Lowers

D.

Lowers

Rises

Lowers

Page 20 of 75

Robinson Nuclear Plant

ILC-i 7 RNP RO NRC Examination

Question:

21

(1 point)

Given the following:

A tube leak developed in the C S/G

The plant has been taken offline lAW AOP-035, SIG TUBE LEAK

Plant cooldown lAW AOP-035 is in progress and the crew is at the step to refill the

affected SIG

Which ONE of the following correctly completes the statements below?

AOP-035 directs the operators to feed the C SIG to

(1)

lAW AOP-035-BD, feed flow rate is initiated slowly to the affected SIG

(2)

A.

(1)70%

(2) to minimize the rate of dilution effects during SIG backfill

B.

(1)78%

(2) to minimize the rate of dilution effects during SIG backfill

C.

(1)70%

(2) to minimize the possibility of a rapid depressurization and reinitiation of

break flow

D.

(1)78%

(2) to minimize the possibility of a rapid depressurization and rein itiation of

break flow

Page 21 of75

Robinson Nuclear Plant

ILC-i 7 RNP RO NRC Examination

Question:

22

(1 point)

Given the following:

The plant is operating at 39% RIP

Condenser Vacuum is degrading

APP-008-A5, CONDENSER LO VACUUM has just illuminated

The crew has entered AOP-012, PARTIAL LOSS OF CONDENSER VACUUM OR

CIRCULATING WATER PUMP TRIP

The BOP subsequently reports:

Turbine is at 280 MWe gross

Condenser Backpressure is 4.0 INHG

Which ONE of the following correctly complete the statements below?

lAW AOP-012, the crew is required to...

AOP-007, TURBINE TRIP BELOW P-8

EOP-E-0, REACTOR TRIP OR SAFETY INJECTION

REFERENCE PROVIDED

A.

trip the Reactor and go to EOP-E-0.

B.

restore compliance with the Condenser Backpressure Limit by reducing

backpressure.

C.

trip the Turbine and go to AOP-007.

D.

restore compliance with the Condenser Backpressure Limit by raising turbine

load.

Page 22 of 75

Robinson Nuclear Plant

ILC-i 7 RNP RO NRC Examination

Question:

23

(1 point)

Given the following:

R-14C, PLANT VENT LOW RANGE GAS MONITOR is in alarm

The crew is in AOP-005, RADIATION MONiTORING SYSTEM

The on-shift RC Tech reports that gas samples indicate A Waste Gas Compressor

is the source of the activity

A clearance is prepared containing the following Waste Disposal (WD) system valves,

all of which are proposed to be closed:

WD-1611, WASTE GAS COMPRESSOR A SUCTION

WD-1 670, WASTE GAS COMPRESSOR A DISCHARGE

WD-1 665, WASTE GAS COMPRESSOR A RECIRC

WD-1669, WASTE GAS COMPRESSOR A NITROGEN SUPPLY

WD-3335, WD-2063A ISOLATION

Which ONE of the following correctly completes the statements below?

The proposed clearance

(jJ

completely isolate the A Waste Gas

Compressor from the Gaseous Waste Disposal System.

lAW AD-OP-ALL-0200, CLEARANCE AND TAGGING, electrical power sources to the

A Waste Gas Compressor are tagged

the mechanical isolation points.

REFERENCE PROVIDED

A.

(1) does

(2) after

B.

(1) does

(2) prior to

C.

(1) does NOT

(2) prior to

D.

(1)doesNOT

(2) after

Page 23 of 75

Robinson Nuclear Plant

ILC-i 7 RNP RO NRC Exctmination

Question:

24

(1 point)

Given the following:

The plant is in mode 1 at 100% power

A confirmed bomb threat is received at 2105

The caller specified that the bomb is located in the control room

The control room is evacuated at 2110

lAW AOP-004, CONTROL ROOM INACCESSIBILITY, the reactor is required to be

tripped from

Li)

Subsequently,

The time is now 2145

The operator in the Charing Pump Room informs the SM that:

1) N-51 indicates 3 x 10 cps and slowly lowering

2) PZR pressure is 2225 psig

3) PZR level is 45%

lAW AOP-004, ATTACHMENT 1, AUXILIARY BUILDING OPERATOR, the operator in

the charging pump room is required to

Which ONE of the following correctly completes the statements above?

A.

(1) the 4KV room or South Cable Vault

(2) start an additional charging pump from the Charging Pump Room

B.

(1) the 4KV room or South Cable Vault

(2) raise the running charging pump speed to maximum using local controls

C.

(1) the Control Room upon evacuation

(2) start an additional charging pump from the Charging Pump Room

D.

(1) the Control Room upon evacuation

(2) raise the running charging pump speed to maximum using local controls

Page 24 of 75

Robinson Nuclear Plant

ILC-i 7 RNP RO NRC Examination

Question:

25

(1 point)

Given the following:

The plant is operating at 100% power

Letdown flow is 45 gpm

The A Charging Pump is operating in AUTO

The B Charging Pump is operating in MANUAL

Subsequently:

R-9, Letdown Line Area Monitor, alarms

The alarm is determined to be valid

The crew enters AOP-005, RADIATION MONITORING SYSTEM

Attachment 9, AREA MONITOR R-9

- LETDOWN LINE AREA

Which ONE of the following correctly completes the statements below?

lAW with Attachment 9 of AOP-005, the operator

Li)

required to isolate

letdown flow.

AOP-005, Attachment 9 actions are taken to

(21

A.

(i)is

(2) filter airborne radioactive material prior to release from the Auxiliary

Building

B.

(1)i5NOT

(2) filter airborne radioactive material prior to release from the Auxiliary

Building

C.

(1)is

(2) reduce the contribution to background radiation levels in the Auxiliary

Building

D.

(i)i5NOT

(2) reduce the contribution to background radiation levels in the Auxiliary

Building

Page 25 of 75

Robinson Nuclear Plant

ILC-i 7 RNP RO NRC Examination

Question:

26

(1 point)

Given the following:

The plant was at 100% RTP

A reactor trip occurred

The turbine fails to trip in auto and manual and the BOP reports it will not runback

The MSIVs fail to close

The crew is responding in FRP-P.1, RESPONSE TO IMMINENT PRESSURIZED

THERMAL SHOCK

RCS temperatures continue to lower

ALL S/Gs indicate 0% Narrow Range

Which ONE of the following correctly completes the statements below?

lAW FRP-P.1, the crew is required to maintain

Once RCS temperature is stable, the crew is required to perform a soak for

C2)

A.

(1) total feed flow> 300 gpm

(2) 28 minutes

B.

(1) total feed flow> 300 gpm

(2) 60 minutes

C.

(1) approximately 60 gpm feed flow to each S/G

(2) 28 minutes

D.

(1) approximately 60 gpm feed flow to each S/G

(2) 60 minutes

Page 26 of 75

Robinson Nuclear Plant

ILC-i 7 RNP RO NRC Examination

Question:

27

(1 point)

Given the following:

A reactor trip occurred due to a loss of off-site power

The crew is in EOP-ES-0.2, NATURAL CIRCULATION COOLDOWN

ONE CRDM fan is in operation

All RCS loops are determined to be ACTIVE

Natural Circulation conditions have been established

Which ONE of the following correctly completes the statements below?

lAW EOP-ES-0.2, the MAXIMUM cooldown rate is

(1)

/60 minutes.

RCS Core T is expected to

(2)

over the next hour.

A.

(1)70°F

(2) lower

B.

(1)70°F

(2) rise

C.

(1)100°F

(2) lower

D.

(1)100°F

(2) rise

Page 27 of 75

Question:

28

(1 point)

Robinson Nuclear Plant

ILC-i 7 RNP RO NRC Examination

Given the following:

The plant is at 100% RIP

Picture

above indicates a B RCP #2 seal leak.

lAW AOP-018, REACTOR COOLANT PUMP ABNORMAL CONDITIONS,

if TOTAL seal leakage exceeds a MINIMUM value of

(2)

a plant trip is

required.

A.

(1)1

(2) 5.7 gpm

B.

(1)1

(2) 8.0 gpm

C.

(1) II

(2) 5.7 gpm

D.

(1) II

(2) 8.0 gpm

II.

Which ONE of the following correctly completes the statements below?

Page 28 of 75

Robinson Nuclear Plant

ILC-1 7 RNP RO NRC Examination

Question:

29

(1 point)

Given the following:

The plant is at 100% power

A loss of the startup transformer occurs

Which ONE of the following correctly completes the statement below?

At the INSTANT that the startup transformer loss occurs, Component Cooling Water

pump(s)

(1)

LOST power.

A.

A ONLY has

B.

B ONLY has

C.

A & C have

D.

A & B have

Page 29 of 75

Robinson Nuclear Plant

ILC-i 7 RNP RO NRC Examination

Question:

30

(1 point)

Which ONE of the following correctly completes the statement below?

The MINIMUM instrumentation and VCT level SETPOINT to initiate automatic

swapover of the charging pump suction to the RWST is as follows:

LT-112

(1)

LT-115,

(2)

and lowering.

A.

(1)OR

(2) 12.4 inches

B.

(1)OR

(2) 14.4 inches

C.

(1)AND

(2) 12.4 inches

D.

(1)AND

(2)14.4 inches

Page 30 of 75

Robinson Nuclear Plant

ILC-i 7 RN? RO NRC Examination

Question:

31

(1 point)

Given the following:

The crew is performing GP-007, PLANT COOLDOWN FROM MODE 3 TO

MODE 5

RCS temperature is at 22OF

Which ONE of the following correctly completes the statements below?

lAW the TRM...,

(1)

of CVCS Heat Tracing is(are) required to be OPERABLE.

ONE of the purposes of the CVCS Heat Tracing is to maintain

(2)

during

large volume borations.

A.

(1) ONLY one channel

(2) VCT temperature

B.

(1) ONLY one channel

(2) solution solubility of Boric acid

C.

(1)two channels

(2) VCT temperature

D.

(1)two channels

(2) solution solubility of Boric acid

Page 31 of 75

Robinson Nuclear Plant

ILC-i 7 RNP RO NRC Examination

Question:

32

(1 point)

Given the following:

The RCS is 205 °F.

GP-007, PLANT COOLDOWN FROM MODE 3 to MODE 5 is in progress.

RHR pump A is in service providing cooling

Subsequently;

The following alarm actuates, APP-001-F7, RHR PMP MOTOR OVLDITRIP

Which ONE of the following correctly completes the statements below?

An A RHR Pump overload condition would be indicated by breaker status lights being

Green light LIT and Red light

(1)

Prior to attempting to start the B RHR Pump lAW AOP-020, LOSS OF RESIDUAL

HEAT REMOVAL (SHUTDOWN COOLING), the COMPLETE set of valve controllers

required to be closed is

(2)

FC-605, RHR HX BYPASS FLOW

HIC-758, RHR HX DISCH FLOW

HIC-142, PURIFICATION FLOW

A.

(1)LIT

(2) FC-605 and HIC-758, ONLY

B.

(J)LIT

(2) FC-605, HIC-758 and HIC-142

C.

(1)OFF

(2) FC-605 and HIC-758, ONLY

D.

(1)OFF

(2) FC-605, HIC-758 and HIC-142

Page 32 of 75

Robinson Nuclear Plant

ILC-i 7 RNP RO NRC Examination

Question:

33

(1 point)

Given the following:

RCS temperature is 150°F

The A Train of RHR is in operation

Which ONE of the following correctly completes the statement below?

lAW OP-201, RESIDUAL HEAT REMOVAL SYSTEM, whenever actions are taken to

introduce dilute boron sources RHR flow must be a MINIMUM of

to

ensure the assumptions of the boron dilution analysis are satisfied.

A.

2800 gpm

B.

3350 gpm

C.

3500 gpm

D.

3750 gpm

Page 33 of 75

Robinson Nuclear Plant

ILC-i 7 RNP RO NRC Examination

Question:

34

(1 point)

Initial conditions:

The plant was at 100% RTP when a LOCA occurred

The crew is performing EOP-E-0, REACTOR TRIP OR SAFETY INJECTION and is

at the step to reset SPDS

MANUAL monitoring of the Critical Safety Function Status Trees (CSFST) is

required

Current conditions:

Containment pressure is 6 psig and slowly rising

RCS pressure is 885 psig and stable

CETs are 690°F and stable

RVLIS full range is 38% and slowly rising

Which ONE of the following correctly completes the statements below?

The terminus for Critical Safety Function 2, CORE COOLING, is

Li)

Assuming that the CORE COOLING CSFST is the HIGHEST terminus upon exiting

EOP-E-0, OMM-022 directs that the CSFSTs be monitored

(2)

OMM-022, EMERGENCY OPERATING PROCEDURES USERS GUIDE

A.

(1) YELLOW

(2) continuously

B.

(1) YELLOW

(2) once every 10-20 minutes

C.

(1) ORANGE

(2) continuously

D.

(1) ORANGE

(2) once every 10-20 minutes

Page 34 of 75

Robinson Nuclear Plant

ILC-1 7 RNP RO NRC Examination

Question:

35

(1 point)

Given the following:

The plant was operating at 100% RTP

A Steam Line Break on B S/G occurred inside the CV

CV Pressure peaked at 18 psig and is currently lowering slowly

RCS Pressure lowered to 1550 PSIG and NOW is 1715 PSIG and stable

The OATC identifies APP-003-C3, PRT HI PRESS is in alarm and PRT level has

risen 2%

Which ONE of the following correctly completes the statements below?

The PRT High Pressure condition

(1)

due to CVC-382, RCP SEAL RETURN

LINE RELIEF lifting.

With NO operator action taken to mitigate the condition, P1-472, PRT PRESSURE, on

the RTGB will reach a MAXIMUM of

before the rupture disk fails.

A.

(1) is NOT

(2) 115 psig

B.

(1)is

(2) 115 psig

C.

(1)is

(2) 100 psig

D.

(1)isNOT

(2) 100 psig

Page 35 of 75

Robinson Nuclear Plant

ILC-1 7 RNP RO NRC Examination

Question:

36

(1 point)

Given the following:

The plant is at 100% RTP

C COW Pump is running, A and B CCW pump are in standby

The OATC has been directed to start CCW Pump A and secure COW Pump C

lAW OP-306, COMPONENT COOLING WATER SYSTEM

When CCW Pump C was stopped, APP-0O1-F5, COW PMP LO PRESS, was

received and cleared

Which ONE of the following correctly completes the statements below?

The C CCW Pump is

(1)

low pressure auto start.

The B COW Pump is

(2)

low pressure auto start.

A.

(1) locked out from

(2) locked out from

B.

(1) available for

(2) locked out from

C.

(1) locked out from

(2) available for

D.

(1) available for

(2) available for

Page 36 of 75

Robinson Nuclear Plant

ILC-1 7 RNP RO NRC Examination

Question:

37

(1 point)

Which ONE of the following correctly completes the statements below?

The PZR Safety Acoustic Monitors are powered from

(1)

The PZR Safety Acoustic Monitors have to be manually reset at

(2)

A.

(1) Distribution Panel A

(2) Instrument Cabinet A

B.

(1) Distribution Panel A

(2) Cabinet ARP-1

C.

(1) Instrument Bus 1

(2) Instrument Cabinet A

D.

(1) Instrument Bus I

(2) Cabinet ARP-1

Page 37 of 75

Robinson Nuclear Plant

ILC-i 7 RNP RO NRC Examination

Question:

38

(1 point)

Given the following:

The plant is at 100% RTP

Rod control in manual

Which ONE of the following will cause the Channel 2 OTL\\T trip SETPOINT to lower?

A.

N-42 upper detector fails high.

B.

Output of T-ave Median Selector fails high.

C.

RCS wide range pressure channel fails low.

D.

Power reduction to 50% with normal pressure and temperature.

Page 38 of 75

Robinson Nuclear Plant

ILC-i 7 RNP RO NRC Examination

Question:

39

(1 point)

Given the following:

The plant is at 100% RTP

PZR Pressure Channel PT-456 has failed HIGH

The appropriate OWP has NOT been implemented

Which ONE of the following correctly completes the statement below?

The remaining actuation logic for the LO PRESS SI is

(jj

and the

LO PRESS SI Block Permissive is

(2)

A.

(1)1/2

(2) 1/2

B.

(1)2/2

(2) 2/2

C.

(1)1/2

(2) 2/2

D.

(1)2/2

(2) 1/2

Page 39 of 75

Robinson Nuclear Plant

ILC-1 7 RNP RO NRC Examination

Question:

40

(1 point)

Given the following:

The plant is recovering from a reactor trip and safety injection due to a SBLOCA in

containment

HVH-1, 2, 3 and 4 Normal Inlet dampers are to be opened lAW OP-921,

CONTAINMENT AIR HANDLING

Which ONE of the following correctly completes the statements below?

In order to re-open the HVH unit Normal Inlet dampers the

(1)

must be reset.

The dampers are repositioned from a keyswitch

A.

(1) Safety Injection signal ONLY

(2) on the RTGB

B.

(1) Safety Injection and Containment Isolation PHASE A signals

(2) on the RTGB

C.

(1) Safety Injection signal ONLY

(2) in the Unit 2 cable spread room

D.

(1) Safety Injection and Containment Isolation PHASE A signals

(2) in the Unit 2 cable spread room

Page 40 of 75

Robinson Nuclear Plant

ILC-i 7 RNP RO NRC Examination

Question:

41

(1 point)

Which ONE of the following correctly completes the statements below?

lAW EOP-ES-1 .3, TRANSFER TO COLD LEG RECIRCULATION,

after stopping a CV Spray Pump, the CV Spray Pump discharge valves are CLOSED

to prevent possible

LIJ

Sl-863A and Sl-863B can be OPENED when

based on the valves

electrical interlock.

Sl-863A, RHR LOOP RECIRC

Sl-863B, RHR LOOP RECIRC

Sl-862A, LOOP RWST ISOL

Sl-862B, RHR LOOP RWST ISOL

A.

(1) contamination of the RWST

(2) RHR pump discharge pressure is <210 PSIG

B.

(1) contamination of the RWST

(2) Sl-862A and Sl-862B are CLOSED

C.

(1) gas binding of the SI system

(2) RHR pump discharge pressure is <210 PSIG

D.

(1) gas binding of the SI system

(2) Sl-862A and Sl-862B are CLOSED

Page 41 of 75

Robinson Nuclear Plant

ILC-i 7 RNP RO NRC Examination

Question:

42

(1 point)

Given the following:

The plant is at 99.5% RIP

The OATC performed a small dilution for Tavg control

Turbine is in OPER AUTO

The following indications are noted in the Control Room over a 20 minute period:

Power Range Nls are increasing

Tavg is lowering

Steam flow and feed flow are slightly elevated

The FWUFM 4 minute average power is 2349 MWt and slowly rising

Which ONE of the following correctly completes the statements below?

(1)

event is in progress.

The crew is required to FIRST reduce power

A.

(1) A main steam line leak

(2) lAW OMM-001-2, SHIFT ROUTINES AND OPERATING PRACTICES

B.

(1) An inadvertent RCS dilution

(2) lAW OMM-001-2, SHIFT ROUTINES AND OPERATING PRACTICES

C.

(1) A main steam line leak

(2) lAW AOP-038, RAPID DOWNPOWER

D.

(1) An inadvertent RCS dilution

(2) lAW AOP-038, RAPID DOWNPOWER

Page 42 of 75

Robinson Nuclear Plant

ILC-1 7 RNP RO NRC Examination

Question:

43

(1 point)

Given the following:

The plant is at 100% RTP

Control Rods are in Manual

PT-446, MS TURB FIRST STAGE PRESS TRANSMITTER, the selected turbine

first stage pressure transmitter, INSTANTANEOUSLY fails to zero

(ASSUME NO OPERATOR ACTION)

Which ONE of the following correctly completes the statements below regarding the

Steam Generator Water Level Control System?

INITIALLY Feed Flow will

(II

At the end of the transient (STEADY STATE TO STEADY STATE), Feed Flow will be

(2)

its original value.

A.

(1) lower

(2) less than

B.

(1) lower

(2) equal to

C.

(1) remain unchanged

(2) less than

D.

(1) remain unchanged

(2) equal to

Page 43 of 75

Robinson Nuclear Plant

ILC-1 7 RNP RO NRC Examination

Question:

44

(1 point)

Given the following:

The plant is in Mode 3

B MDAFW Pump is running

A feedline break occurs between FCV-1 425, MDAFW PUMP B FCV, and V2-20B,

AFW HDR SECTION valve

The break is isolated and a clearance is hung to isolate the section of piping, Single

Valve isolation

Which ONE of the following correctly completes the statement below?

When the break is isolated, the crew will be able to feed

with the A

MDAFW pump.

A.

SIG A ONLY

B.

S/GBONLY

C.

S/Gs A and B ONLY

D.

S/Gs A, B, and C

Page 44 of 75

Robinson Nuclear Plant

ILC-i 7 RNP RO NRC Examination

Question:

45

(1 point)

Given the following:

The plant is at 100% RTP

Emergency Diesel Generator (EDG) A is started and paralleled to the 480V Bus

E-1 for surveillance testing

EDG A is loaded to 1100 KW

A lagging power factor (+VARS) has been established

Which ONE of the following correctly completes the statement below?

(1)

the voltage control potentiometer will cause the generator to pick up a

larger share of the

(2)

load.

A.

(1) Lowering

(2) reactive

B.

(1) Raising

(2) reactive

C.

(1) Lowering

(2) real

D.

(1) Raising

(2) real

Page 45 of 75

Robinson Nuclear Plant

ILC-i 7 RNP RO NRC Examination

Question:

46

(1 point)

Given the following:

The plant is in Mode 3

DC Distribution Panel B was de-energized due to a fire

Which ONE of the following correctly completes the statements below?

Control Power has been lost to 41 60V Busses

(1)

Control Power to the 41 60V Busses

be restored using a safety switch in

the 4160V Switchgear Room.

A.

(1)1&2

(2) can

B.

(1)1&2

(2) can NOT

C.

(1)3&4

(2) can

D.

(1)3&4

(2) can NOT

Page 46 of 75

Robinson Nuclear Plant

ILC-i 7 RNP RO NRC Examination

Question:

47

(1 point)

Due to an accident coupled with a Loss of Offsite Power, Emergency Diesel Generator

(EDG) A has operated at 110% of the maximum continuous load rating for the last 30

minutes.

Which ONE of the following correctly completes the statement below?

The EDG A is loaded to

(1)

, and can remain at this load for an additional

(2)

A.

(1)2200KW

(2) 30 minutes

B.

(1)2200KW

(2) 90 minutes

C.

(1)2750KW

(2) 30 minutes

D.

(1)2750KW

(2) 90 minutes

Page 47 of 75

Robinson Nuclear Plant

ILC-i 7 RNP RO NRC Examination

Question:

48

(1 point)

Given the following:

The plant was at 100% RTP

A LOCA coincident with a loss of Off-Site Power occurred

Safety Injection has been reset

The BOP observes APP-010-A1, EMERG GEN NB AUTO-TRIP alarms and the

following indications:

..

E1ERGS B

TO J SE?

0KB 50278

..

Which ONE of the following correctly completes the statements below?

Breaker 52117B, EMERG DGATO BUS El tripped on

(1)

IF the BOP places the BKR 52117B control switch on the RTGB to TRIP, BKR 52/17B

(2)

automatically re-close.

Over Power, 51V-A-ADG, OVERCURRENT RELAY

Over Current, AMPTECTOR ON 52/17B

A.

(1) Over Power

(2) will

B.

(1) Over Power

(2) will NOT

C.

(1) Over Current

(2) will

D.

(1)OverCurrent

(2) will NOT

TEL

EMER2 DIESEL

TOlERATOR A

STOP

SORT

O I

ELERO DOS

TO BUS El

BAR 50178

TOP

CLOSE I [1

OPERO DIESEL

ONERATOR B

STOP

SORT

O

TRIP

005Ea

Page 4$ of 75

Robinson Nuclear Plant

ILC-17RNPRO NRC Examination

Question:

49

(1 point)

Given the following:

The crew has entered AOP-035, S/G TUBE LEAK based on multiple indications of

A S/G tube leakage

The crew has performed an OST-051, Reactor Coolant System Leakage

Evaluation, and determined unidentified leakage of 0.04 gpm

Chemistry has confirmed the primary to secondary leak rate is 0.04 gpm

Which ONE of the following correctly completes the statements below?

lAW AOP-035 a

(1)

event has occurred.

AOP-035-BD states that radiation monitor R-24A is NOT a reliable indicator when less

than

(2)

power.

A.

(1) PSAL-3

(2) 40%

B.

(1) PSAL-3

(2) 50%

C.

(1) PSAL-1

(2) 40%

D.

(1) PSAL-J

(2) 50%

Page 49 of 75

Robinson Nuclear Plant

ILC-1 7 RNP RO NRC Examination

Question:

50

(1 point)

Given the following:

The plant is in MODE 3

A release is in progress from A Waste Gas Decay Tank

R-14C, PLANT VENT LOW RANGE GAS MONITOR, FAIL light illuminates due to

low counts

Which ONE of the following correctly completes the statements below?

RCV-014, WASTE GAS RELEASE ISOLATION will

LIJ

The R-14 Skid

(2)

shift to the Intermediate/Mid Range.

A.

(1) remain OPEN

(2) will

B.

(1) remain OPEN

(2) will NOT

C.

(1) automatically CLOSE

(2) will

D.

(1) automatically CLOSE

(2) will NOT

Page 50 of 75

Robinson Nuclear Plant

ILC-i 7 RNP RO NRC Examination

Question:

51

(1 point)

Given the following:

The plant is at 100% RTP

OST-021, DAILY SURVEILLANCES is in progress

The following data is recorded for SW temperature

HVH-1

HVH-2

HVH-3

HVH-4

Tl-1662A, B, C, D

96°F

96°F

98°F

97°F

High Accuracy

95°F

95°F

97°F

96°F

Temperature

Instrument

Which ONE of the following correctly completes the statement below?

Entry into Tech Spec LCO 3.7.8 required actions

(1)

required based on

TI-i 662A, SWBP A TO HVH 1 TEMP INDICATOR

TI-I 662B, SWBP B TO HVH 2 TEMP INDICATOR

TI-i 662C, SWBP C TO HVH 3 TEMP INDICATOR

TI-I 662D, SWBP D TO HVH 4 TEMP INDICATOR

A.

(1)is

(2) the highest TI-1662 reading

B.

(1)is

(2) the highest High Accuracy Temperature Instrument reading

C.

(1) is NOT

(2) the average of the TI-i 662 readings

D.

(1)isNOT

(2) the average of the High Accuracy Temperature Instrument readings

Page 51 of 75

Robinson Nuclear Plant

ILC-i 7 RNP RO NRC Examination

Question:

52

(1 point)

Initial conditions:

SW-739, CCW HEAT EXCHANGER A RETURN, and SW-740, CCW HEAT

EXCHANGER B RETURN, are initially throttled open to LESS THAN POSITION

I

Subsequently:

SW-739 & SW-740 are throttled CLOSED an additional 1/2 turn.

Which ONE of the following correctly completes the statement below?

As a result of these manipulations, from steady-state to steady-state...

Service Water Header PRESSURE will

(1)

CCW Heat Exchanger Outlet TEMPERATURE will

A.

(1) lower

(2) lower

B.

(1) lower

(2) rise

C.

(1) rise

(2) lower

D.

(1) rise

(2) rise

Page 52 of 75

Question:

53

(1 point)

Robinson Nuclear Plant

ILC-i 7 RNP RO NRC Examination

Given the following:

The plant is at 100% RTP

APP-002-F7, INSTR AIR HDR LO PRESS was received 10 minutes ago

The crew is progressing in AOP-017, LOSS OF INSTRUMENT AIR

The following indications are observed:

lAW AOP-017, the crew is required to trip the reactor, based on

(1)

AOP-017

(2)

a concurrent use procedure.

A.

(1) SGWLC being adversely affected

(2) is NOT

B.

(1) SGWLC being adversely affected

(2) is

C.

(1) IA header pressure exceeding the trip limit established by the AOP

(2) is NOT

D.

(1) IA header pressure exceeding the trip limit established by the AOP

(2) is

Which ONE of the following correctly completes the statements below?

Page 53 of 75

Robinson Nuclear Plant

ILC-i 7 RNP RO NRC Examination

Question:

54

(1 point)

Given the following:

The plant was at 100% RTP

A reactor trip and loss of offsite power occurred

Which ONE of the following correctly completes the statement below?

Two minutes into the event, Instrument Air Compressor(s)

have power

available.

A.

A and D

B.

and B

C.

B and Primary Air Compressor

D.

D and Primary Air Compressor

Page 54 of 75

Robinson Nuclear Plant

ILC-i 7 RNP RO NRC Examincttion

Question:

55

(1 point)

Which ONE of the following conditions concerning the Personnel Air Lock would

REQUIRE entering an LCO Action Statement?

A.

Both air lock doors fail acceptance test criteria while the plant is in MODE 6.

B.

Welding cables are laid through both airlock doors while the plant is in MODE

5.

C.

The outer door is opened for a normal entry into Containment while the plant is

in MODE 3.

D.

The inner and outer doors are opened simultaneously for a normal entry into

Containment while the plant is in MODE 4.

Page 55 of 75

Robinson Nuclear Plant

ILC-1 7 RNP RO NRC Examination

Question:

56

(1 point)

During a power ascension in accordance with GP-005, POWER OPERATION, Power

Range NIs and Calorimetric power indicate 28% power.

Which ONE of the following is the expected RCS Core Delta T for the indicated power

level?

A.

8.1°F

B.

8.7°F

C.

16.1°F

D.

21.0°F

Page 56 of 75

Robinson Nuclear Plant

ILC-i 7 RNP RO NRC Examination

Question:

57

(1 point)

Given the following:

The plant is at 100% RTP

Several alarms illuminate and the OATC observes LT-460 indication off scale LOW

(ASSUME NO OPERATOR ACTIONS)

Which ONE of the following correctly completes the statements below?

Over the first minute of this event...

Charging pump speed will

(1)

and

Letdown will

(2)

A.

(1) RISE

(2) remain in service

B.

(1) RISE

(2) automatically isolate

C.

(1) LOWER

(2) remain in service

D.

(1) LOWER

(2) automatically isolate

Page 57 of 75

Robinson Nuclear Plant

ILC-1 7 RNP RO NRC Examination

Question:

58

(1 point)

Which ONE of the following correctly completes the statements below?

APP-005-A2, IR HI LEVEL ROD STOP actuates when

(1)

lRNls are at

current equivalent to 20% power.

If IR LOGIC TRIP DEFEAT TRAIN A and TRAIN B pushbuttons are pushed

sequentially, IR LOGIC TRIPS

(2)

blocked.

A.

(1)2of2

(2) are

B.

(1)2of2

(2) are NOT

C.

(1)lof2

(2) are

D.

(1)lof2

(2) are NOT

Page 58 of 75

Robinson Nuclear Plant

ILC-1 7 RNP RO NRC Examination

Question:

59

(1 point)

Given the following:

You have been assigned to perform OST-OJO, POWER RANGE CALORIMETRIC

DURING POWER OPERATION DAILY

Indicated power level values are:

N-41: 97.2%

N-42: 99.7%

N-43: 99.3%

N-44: 100.6%

Calculated power level is 99.5%

Which ONE of the following statements is correct?

A.

N-41 adjustment is REQUIRED, ONLY.

B.

N-44 adjustment is REQUIRED, ONLY.

C.

N-41 and N-44 adjustment is REQUIRED.

D.

NO adjustment is REQUIRED based on data recorded.

Page 59 of 75

Robinson Nuclear Plant

ILC-i 7 RNP RO NRC Examination

Question:

60

(1 point)

Given the following:

A GP-006-1, NORMAL PLANT SHUTDOWN FROM POWER OPERATION TO

HOT SHUTDOWN is in progress to support a scheduled refueling outage

The turbine is tripped

Tavg is being controlled at 547°F by the Steam Dumps in Pressure Control Mode

Subsequently, P1-464, STEAM HEADER PRESSURE fails high.

Which ONE of the following correctly completes the statements below?

Steam Dump

(1)

will OPEN.

At a condenser vacuum SETPOINT of

(2)

the Steam Dumps will NO

LONGER be armed.

A.

(1) Bank 1 ONLY

(2) 19.7 HG

B.

(1) Bank I ONLY

(2) 21.0 HG

C.

(1) Banks I and 2

(2) 19.7 HG

D.

(1) Banks 1 and 2

(2) 21.0 HG

Page 60 of 75

Robinson Nuclear Plant

ILC-i 7 RNP RO NRC Examination

Question:

61

(1 point)

Which ONE of the following is the power supply for HVE-3, CV AIR IODINE REMOVAL

Fan?

A.

MCC-5

B.

MCC-6

C.

MCC-9

D.

MCC-1O

Page 61 of75

Robinson Nuclear Plant

ILC-1 7 RNP RO NRC Examination

Question:

62

(1 point)

Given the following:

The plant is in MODE 5

The equipment hatch is removed lAW OMM-033, IMPLEMENTATION OF CV

CLOSURE

A Containment Purge is in progress lAW OP-921, CONTAINMENT AIR HANDLING

R-14C, PLANT VENT LOW RANGE GAS MONITOR is Out of Service (OOS)

HVE-1A, CV PURGE FAN is in operation

Containment radiation monitors are all trending up slowly

Which ONE of the following correctly completes the statements below?

To commence the Purge operation

(11

MUST be in operation.

IF R-1 1, CV AIR & PLANT VENT PARTICULATE alarms, HVE-IA

automatically stop.

A.

(1) both R-1J AND R-12

(2) will

B.

(1) either R-1 I OR R-1 2

(2) will

C.

(1) both R-11 AND R-12

(2) will NOT

D.

(1) either R-11 ORR-12

(2) will NOT

Page 62 of 75

Robinson Nuclear Plant

ILC-1 7 RNP RO NRC Examination

Question:

63

(1 point)

Given the following:

The plant is at 100%

A seismic event has occurred several minutes ago

APP-036-B6, SPENT FUEL PIT LO LEVEL, has just illuminated

SFPC Pump B is aligned for service

lAO reports leakage is coming from UPSTREAM of SFPC-796, SFPC PUMP B HI

LEVEL SUCTION

Which ONE of the following correctly completes the statements below?

lAW AOP-036, SEP EVENTS, spent fuel pool cooling

(1)

be restored by

placing SFPC Pump A in service.

Subsequently,

Maintenance has repaired the leaking pipe

OP-913, REFUELING WATER PURIFICATION PUMP OPERATION, is being used

to restore spent fuel pool (SFP) to normal level

lAW AOP-036, the addition of 550 lbs of boric acid for every foot level added to the

SFP

(2)

required.

A.

(1) will

(2) is

B.

(1) will

(2) is NOT

C.

(1)wiIINOT

(2) is

D.

(1)wiII NOT

(2) is NOT

Page 63 of 75

Robinson Nuclear Plant

ILC-1 7 RNP RO NRC Examination

Question:

64

(1 point)

Given the following:

The plant is at 100% power

FCV-478, S/G A FWRV (Feedwater Regulating Valve) is failing open

Which ONE of the following correctly completes the statements below?

Operators will FIRST receive

(1)

Subsequently:

All operator actions to control FCV-478 have failed

Assuming no additional operator actions, the FIRST automatic reactor trip signal that

occurs is

t2)

APP-006-A3, S/G A LVL DEV

APP-006-D2, S/G A NAR RANGE HI LEVEL

A.

(1) APP-006-A3

(2) Turbine Trip

B.

(1) APP-006-A3

(2) Steam Generator LO-LO level

C.

(1) APP-006-D2

(2) Turbine Trip

D.

(1) APP-006-D2

(2) Steam Generator LO-LO level

Page 64 of 75

Robinson Nuclear Plant

ILC-1 7 RNP RO NRC Exctrnination

Question:

65

(1 point)

Given the following:

The plant is at 100% RIP

A release of Waste Condensate Tank (WCT) D is in progress.

Annunciator APP-036-E7, RAD MONITOR TROUBLE, is received.

The BOP Operator reports the FAIL light for R-18, LIQUID WASTE DISPOSAL

MONITOR, is illuminated.

Which ONE of the following correctly completes the statement below?

RCV-018, LIQUID WASTE RELEASE ISOLATION VALVE will...

A.

NOT automatically close. The release must be manually terminated.

B.

NOT automatically close. The release may continue lAW APP-036-E7

Annunciator Procedure.

C.

automatically close when the monitor FAIL light is illuminated. The release can

NOT continue under the current release permit.

D.

automatically close when the monitor FAIL light is illuminated. The release can

continue lAW APP-036-E7 Annunciator Procedure, RCV-01 8 must be

manually bypassed.

Page 65 of 75

Robinson Nuclear Plant

ILC-i 7 RNP RO NRC Examination

Question:

66

(1 point)

Given the following

You are OATC on shift and require a short term relief to meet with the PGM

Which ONE of the following correctly completes the statements below?

lAW AD-OP-ALL-I 000, if you are relieved for GREATER THAN

(I)

, then a

Narrative Log Entry, formal turnover and shift turnover sheet, and the logs signed over

MUST occur.

lAW AD-OP-ALL-I 000, if you return to the Control Room 15 minutes after being

relieved, a briefing

required.

A.

(1) 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />

(2) is

B.

(1) 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />

(2) is NOT

C.

(I) 20 minutes

(2) is

D.

(1) 20 minutes

(2) is NOT

Page 66 of 75

Robinson Nuclear Plant

ILC-1 7 RNP RO NRC Examination

Question:

67

(1 point)

Given the following:

The plant is at 100% RTP for the past three weeks

Chemistry has just provided the following results from a Reactor Coolant System

sample that was taken 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> ago:

RCS Chloride: 0.1 ppm

RCS Oxygen: 0.15 ppm

Which ONE of the following correctly completes the statements below?

The

concentration exceeds the TRMS 3.5, REACTOR COOLANT

OXYGEN AND CHLORIDE CONCENTRATION limit.

lAW TRMS 3.5 CONDITION A, action to restore compliance with the TRMS must be

initiated with a COMPLETION TIME of

(2)

A.

(1) Oxygen

(2) 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />

B.

(1) Oxygen

(2) immediately

C.

(1) Chloride

(2) 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />

D.

(1) Chloride

(2) immediately

Page 67 of 75

Robinson Nuclear Plant

ILC-1 7 RNP RO NRC Examination

Question:

68

(1 point)

Given the following:

Core Reload is in progress lAW GP-O1O, REFUELING

Consider the following list of responsibilities:

1) Maintains and evatuates the 1/M plot during core loading

2) Determines fuel movement sequence

3) Advises the Refueling SRO that conditions are acceptable or unacceptable for

authorizing gripper unlatching for fuel assembly insertion into the core

Which ONE of the following correctly completes the statement below?

lAW OMM-OO1-18, OUTAGES, the Reactivity Monitor stationed in the Control Room is

responsible for....

A.

I ONLY

B.

2 ONLY

C.

1AND3

D.

2AND3

Page 68 of 75

Robinson Nuclear Plant

ILC-1 7 RNP RO NRC Examination

Question:

69

(1 point)

Given the following:

The plant is in Mode 3

Preparations for a post trip startup lAW GP-003, NORMAL PLANT STARTUP

FROM HOT SHUTDOWN TO CRITICAL are in progress

The Outside AO has been directed to perform Section 6.14. BLOWDOWN TO THE

FLASH TANK WITH HEAT RECOVERY BYPASSED of OP-406, STEAM

GENERATOR BLOWDOWN IWET LAYUP SYSTEM

lAW AD-OP-ALL-0203, REACTIVITY MANAGEMENT, which ONE of the following

correctly completes the statements below?

A Dedicated Licensed Operator

(1)

requited to be present in the field with

the AO when performing this task.

The OATC

authorize the performance of this reactivity manipulation

without CRS/Reactivity Manager oversight.

A.

(1)is

(2) can

B.

(1) is NOT

(2) can

C.

(1)is

(2) can NOT

D.

(1)isNOT

(2) can NOT

Page 69 of 75

Robinson Nuclear Plant

fiX-i 7 RNP RO NRC Examination

Question:

70

(1 point)

Given the following:

The plant is in MODE 3 at 547°F

A transient causes RCS pressure to rapidly increase

Which ONE of the follow

correctly completes the statements below?

(1)

If the RCS Pressure Safety Limit is exceeded, the MAXIMUM amount of time to

restore compliance per Tech Specs is

(2)

A.

(1)<2485PS1G

(2) one hour

B.

(1)<2735PS1G

(2) one hour

C.

(1)<2485PS1G

(2) five minutes

D.

(1)<2735PS1G

(2) five minutes

A/AJ&

In

/N/S74-72O//

1Z:7

SVITE

- -

Rs

r

(L

t.

Page 70 of 75

Robinson Nuclear Plant

ILC-i 7 RNP RO NRC Examination

Question:

71

(1 point)

Initial conditions:

The plant is at 100% RTP

Which ONE of the following activities requires entry into a Technical Specifications

LCO action statement?

(CONSIDER EACH OF THE BELOW CHOICES INDEPENDENTLY OF EACH OTHER)

A.

Charging Pump A removal from service for oil change.

B.

Boric Acid Transfer Pump B recirc valve leak repair.

C.

CCW Pump A mechanical seal repair.

D.

CCW Pump B breaker repair.

Page 71 of75

Robinson Nuclear Plant

ILC-1 7 RNP RO NRC Examination

Question:

72

(1 point)

Given the following:

GP-007, PLANT COOLDOWN FROM HOT SHUTDOWN TO COLD SHUTDOWN

is in progress

You have been assigned by the WCC SRO to hang a clearance on the RCS Filter

for replacement

RCS Filter radiation levels are 1100 mrem/hr at 30 cm from the filter housing

Which ONE of the following correctly completes the statements below?

lAW AD-RP-ALL-201 7, the radiation area is required to be classified as a

lAW AD-HU-ALL-0005, the Independent / Concurrent Verification

(2)

be

waived.

AD-RP-ALL-2017, ACCESS CONTROLS FOR HIGH, LOCKED HIGH, AND VERY

HIGH RADIATION AREAS

AD-HU-ALL-0005, HUMAN PERFORMANCE TOOLS

A.

(1) Locked High Radiation Area

(2) can

B.

(1) High Radiation Area

(2) can

C.

(1) Locked High Radiation Area

(2) can NOT

D.

(1) High Radiation Area

(2) can NOT

Page 72 of 75

Robinson Nuclear Plant

ILC-i 7 RNP RO NRC Examination

Question:

73

(1 point)

Given the following:

A LOCA has occurred

Both SI pumps have tripped

All RCPs have been stopped

The crew is performing FRP-C.1, RESPONSE TO INADEQUATE CORE COOLING

Subsequently, RWST level lowers to 27%

Which ONE of the following correctly completes the statement below?

The EARLIEST the crew is required to transition to EOP-ES-1 .3, TRANSFER TO

COLD LEG RECIRCULATION is

A.

immediately

B.

when APP-002-B3, RWST LO-LO LVL alarms

C.

when all actions of FRP-C.1 have been completed

D.

when at least 1 RCP has been started lAW FRP-C.1

Page 73 of 75

Robinson Nuclear Plant

ILC-1 7 RNP RO NRC Examination

Question:

74

(1 point)

Which ONE of the following correctly completes the statement below?

With respect to Fire Protection Procedures, specific room guidelines for the Fire

Brigade to fight a fire in the Auxiliary Building are located in

A.

FP-OO1, FIRE EMERGENCY

B.

AOP-041, RESPONSE TO FIRE EVENT

C.

OMM-002, FIRE PROTECTION MANUAL

D.

OMM-003, FIRE PROTECTION PRE-PLANS

Page 74 of 75

Robinson Nuclear Plant

ILC-1 7 RNP RO NRC Examination

Question:

75

(1 point)

Given the following:

The plant is in Mode 6

During testing of RTGB annunciators several annunciators were not received

The crew has entered AOP-054, LOSS OF CONTROL ROOM ANNUNCIATORS

Which ONE of the following correctly completes the statements below?

The crew will direct the Outside AO to check Breaker 12, Lundell AC, on Instrument

Bus

(1)

The OAO reports the breaker is tripped, and that there are no apparent signs of

damage or abnormal odors.

The breaker can be reset one time

(2)

, with CRS approval.

A.

(1)2

(2) IMMEDIATELY

B.

(1)3

(2) following a Live-Dead-Live check lAW OP-603-2, ELECTRICAL LIVE-

DEAD-LIVE CHECKS

C.

(1)2

(2) following a Live-Dead-Live check lAW OP-603-2, ELECTRICAL LIVE

DEAD-LIVE CHECKS

D.

(1)3

(2) IMMEDIATELY

Page 75 of 75

Examination KEYfor: ILC-i 7 RNP RO NRC Exan;in

Question

Answer

Nuntber

1

B

2

C

3

D

4

B

5

C

6

A

7

C

8

D

9

D

10

C

11

A

12

C

13

A

14

D

15

A

16

C

17

D

18

B

19

D

20

A

21

C

22

A

23

B

24

D

25

D

Printed 10/25/2017 10:26:32 AM

Page 1 of3

Examination KEYfor: IIX-17RNPRO NRCExamin

Question

Answer

Number

26

D

27

C

28

D

29

C

30

C

31

D

32

B

33

A

34

C

35

C

36

A

37

C

38

A

39

B

40

C

41

C

42

A

43

B

44

C

45

B

46

C

47

D

48

C

49

C

50

D

Printed 10/25/2017 10:26:32 AM

Page 2 of3

Examination KEYfor: ILC-1 7 RNP RO NRC Exarnin

Question

Answer

Nuntber

51

D

52

D

53

B

54

B

55

D

56

C

57

D

58

C

59

A

60

C

61

A

62

C

63

D

64

A

65

A

66

A

67

B

68

C

69

D

70

D

71

D

72

A

73

A

74

D

75

A

Printed 10/25/2017 10:26:33 AM

Page 3 of3

500

400

300

200

100

0

FIGURE 1

MINIMUM ECCS FLOW RATE VERSUS TIME AFTER TRIP

Page 1 of I

Rev. 2

EOP-ECA-J.1

LOSS OF EMERGENCY COOLANT RECIRCULATION

Page 32 of 38

FLOW

RATE

(GPM)

600

10

100

1000

10000

TIME

(MINUTES)

6.0

r

ci

5.0

ci

ci

4.0

ci

C

ci

  • 0C

8 3.0

Note: Zero load condenser

backpressure limit applies

down to 10% rated turbine

speed

ATTACHMENT 3

9.0

8.0

7.0

CONDENSER BACKPRESSURE LIMIT

Siemens Curve

Number: CT-27466C

2.0

1.0

0.0

Backpresssre Limit

0

100

200

300

400

500

600

700

800

900

Gross Load (MWe)

8

7

I

6

I

5

cwwol6I3

I

4

I

3

2

I

IWD152R191

er a;;

TANKS

l_WO_IZN_II4j

_D_25O3R.l&S

B

-

-w

_____________

_flO72

  • t:ns

ITh_ThM

l52Rl35

I

___

%

___

______

m

____ ____

7) >

W5C GS COPRSSOR

PKG

A

___

________

__

_]

-

E

,e

NOTE

I

cv

CWDAS M4L11Efl

lff5

wo

V

- -

-

STATION

Lzz__zzi

-

8

7

5

I

4

I

3

I

2

I