Southem California Edison Company P. 0. BOX 800 2244 WALNUT GROVE AVENUE ROSEMEAD, CALIFORNIA 91770 M.O.MEDFORD TELEPHONE MANAGER OF NUCLEAR ENGINEERING (818) 302-1749 AND LICENSING April 1, 1987 U. S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, D.C. 20555 Gentlemen:

Subject:

Docket No. 50-206 Reliability Evaluation of the Saltwater Cooling System SEP Topic IX-3, Station Service and Cooling Water Systems San Onofre Nuclear Generating Station Unit 1

Reference:

Letter, M. 0. Medford, SCE, to 3. A. Zwolinski, NRC, dated October 4, 1985 One of the recommendations of NUREG-0829, "Integrated Plant Safety Assessment," for San Onofre Unit 1 was that SCE perform a reliability evaluation of the Saltwater Cooling (SWC) System. In the referenced letter we committed to perform such a study.

Enclosed is a reliability assessment of the SONGS 1 SWC System. The study concludes that the system as designed provides a very reliable means of removing decay heat. The study did not identify any improvements to design or changes to procedures that would further improve system reliability.

Considering these results, no further actions are planned on this subject.

This topic is now closed.

If there are any questions, please let me know.

Very truly yours, Enclosure cc:

R. F. Dudley, NRR Project Manager, San Onofre Unit 1 J. B. Martin, Regional Administrator, NRC Region V F. R. Huey, NRC Senior Resident Inspector, San Onofre Units 1, 2 and 3 8704060529 870401 PDR ADOCK 05000206 P

PDR