Information Notice 2012-19, License Renewal Post-Approval Site Inspection Issues

From kanterella
(Redirected from ML12242A195)
Jump to navigation Jump to search
License Renewal Post-Approval Site Inspection Issues
ML12242A195
Person / Time
Issue date: 10/23/2012
From: Mcginty T
Division of License Renewal
To:
Jones H
References
IN-12-019
Download: ML12242A195 (6)


UNITED STATES

NUCLEAR REGULATORY COMMISSION

OFFICE OF NUCLEAR REACTOR REGULATION

WASHINGTON, DC 20555-0001 October 23, 2012 NRC INFORMATION NOTICE 2012-19: LICENSE RENEWAL POST-APPROVAL SITE

INSPECTION ISSUES

ADDRESSEES

All holders of or applicants for operating licenses for nuclear power reactors under the

provisions of Title 10 of the Code of Federal Regulations (10 CFR) Part 50, Domestic Licensing

of Production and Utilization Facilities, except those who have permanently ceased operations

and have certified that fuel has been permanently removed from the reactor vessel.

PURPOSE

The U.S. Nuclear Regulatory Commission (NRC) is issuing this information notice (IN) to inform

addressees of issues of concern identified during inspection procedure (IP) 71003 inspections, Post-Approval Site Inspection for License Renewal, (Agencywide Documents Access and

Management System [ADAMS] Accession No. ML082830294), related to the management and

implementation of the aging management programs (AMPs) described in the updated final

safety analysis report (UFSAR) supplement, regulatory commitments for license renewal, and

license conditions that are added as part of the renewed license. The examples of

discrepancies included in this IN could have generic implications and may impact the licensees

ability to meet a commitment or effectively implement an AMP as was intended by the various

license renewal documents. Licensees are reminded to apply thoroughness, diligence, and

attention to detail when implementing, managing, and controlling the UFSAR supplement, commitments for license renewal, and license conditions that are specific to license renewal.

The NRC expects that recipients will review the information for applicability to their facilities and

consider actions, as appropriate, to avoid similar problems. Suggestions contained in this IN

are not NRC requirements; therefore, no specific action or written response is required.

BACKGROUND

The NRC regulations in 10 CFR Part 54, Requirements for Renewal of Operating Licenses for

Nuclear Power Plants, provide a means by which licensees can obtain a renewed operating

license which allows continued operation of a nuclear power plant beyond its original license

term (40 years). NUREG-1801, Generic Aging Lessons Learned (GALL) Report, Revision 2, issued December 2010 (hereafter referred to as the GALL Report), provides recommended

programs that the NRC staff finds acceptable to manage the aging effects of passive and

long-lived systems, structures, and components as plants enter the period of extended

operation. License conditions are added to a renewed license to allow for changes to the

licensees AMPs in accordance with NRC requirements and to ensure that certain future

programs and activities are completed before the period of extended operation.

ML12242A195 As licensees approach the period of extended operation, the NRC regional offices conduct

inspections using IP 71003. The objectives of IP 71003 inspections include: (1) verifying the

implementation of license conditions added as part of the renewed license and regulatory

commitments for license renewal; and (2) confirming that the licensee has implemented the

AMPs as described in the UFSAR supplement. A majority of these inspections are conducted

before the licensee enters the period of extended operation. The inspections are scheduled to

support completion of the review in sufficient time for licensees to make any necessary

corrections to their AMPs before entering the period of extended operation.

DESCRIPTION OF CIRCUMSTANCES

The NRC staff has performed many post-approval site inspections for license renewal at

several plants, shortly before the plants entered the period of extended operation. The

following information in this section describes issues that were identified during IP 71003 inspections conducted from 2009 to 2012.

Oyster Creek Generating Station - Implementation of Corrosion Prevention Measures

Several issues were identified involving license renewal activities to implement corrosion

prevention measures. Specifically, a strippable coating that was applied to the reactor cavity

liner to prevent water leakage and protect the drywell shell from corrosion, unexpectedly de- laminated. This allowed water to leak into the gap between the drywell shell and concrete

shield wall and flow down the outside of the drywell shell into four of the ten sand bed bays.

Additionally, NRC inspectors identified that an established administrative limit for cavity seal

leakage did not prevent water intrusion into the gap. Further, the licensee monitored for water

leakage from the sand bed bay drains by checking bottles connected via tygon tubing and

funnels to the sand bed bay drain lines. Subsequently, the licensee identified that the tubing

was not connected to the drain lines for two sand bed bays. When deficiencies or

nonconformances are identified associated with the inadequate implementation of activities for

license renewal, it is important that licensees establish corrective actions to prevent the

ineffective aging management of systems, structures, and components. This event is described

in Oyster Creek Generating Station-NRC License Renewal Follow-Up Inspection Report 05000219/2009006, dated May 18, 2009 (ADAMS Accession No. ML091380379).

Dresden Nuclear Power Station Unit 2 - Implementation of the One-Time Inspection Program

NRC inspectors identified instances in which the licensees one-time inspection of a system

(i.e., a ventilation system) identified degradation (i.e., ducting corrosion), but the evaluation to

address the identified aging effect was inadequate. Specifically, the licensee scheduled

follow-up examinations of the identified degraded system and did not conduct an

extent-of-condition review for other similar in-scope systems, such as other ventilation systems

with ducting of the same material under similar environmental conditions. The purpose of the

one-time inspection program is to provide reasonable assurance that an aging effect, such as

degradation from corrosion, is not occurring or that the aging effect is occurring in a manner

such that the component or structures intended function(s) will not be affected during the period

of extended operation and, therefore, not require additional aging management (e.g., measures

to monitor and prevent corrosion of that structure or component). If a one-time inspection

identifies age-related degradation that could jeopardize an intended function before the end of

the period of extended operation, the one-time inspection program calls for the licensee to: (1) perform an evaluation of the need for follow-up examinations to monitor the progression of any

age-related degradation; and (2) perform an extent-of-condition review. This event is described

in Dresden Nuclear Power Station, Unit 2 NRC Post-Approval Site Inspection for License

Renewal Inspection Report 05000237/2009007, dated December 22, 2009 (ADAMS Accession

No. ML093570258).

Palisades Nuclear Plant - Management of CHECWORKS Software

Consistent with the GALL Report, some licensees made regulatory commitments that were

incorporated into the UFSAR that stated an effective flow accelerated corrosion program

includes analysis using a predictive code, such as CHECWORKS. NRC inspectors identified

one example in which the licensee classified and managed the CHECWORKS software at a

lower level (i.e., Business Important instead of Regulatory Commitments) than what was

specified in the licensees procedure for software quality assurance. It is important that any

software used to perform calculations be classified and managed in accordance with licensee

procedures for software quality assurance to ensure that the appropriate software quality

assurance requirements are applied during installation and testing of the program, and prior to

its use. Also, it should be noted that regulatory commitments incorporated as part of the

UFSAR supplement are considered components of the UFSAR, and are managed in

accordance with the requirements of 10 CFR 50.59, Changes, tests, and experiments. This

event is described in Palisades Nuclear Plant Post-Approval Site Inspection for License

Renewal, Inspection Report 05000255/2011008 (DRS), dated May 6, 2011 (ADAMS Accession

No. ML11126A328).

H.B. Robinson Steam Electric Plant (H.B. Robinson) and Surry Power Station (Surry) Units 1 and 2 - Implementation of Procedures for AMPs

NRC inspectors identified one example where steps added to site-specific procedures in order

to satisfy a UFSAR action item, which consisted of enhancements to the systems monitoring

program, were inadvertently deleted as a result of a procedure revision. The procedure revision

deleted enhancements made to the list of aging effects included in a system walkdown

checklist. The elimination of such enhancements occurred during a transition from site-specific

procedures to corporate procedures. The resulting implementation procedures would not have

provided adequate guidance to meet the action as described in the plants UFSAR because one

of the applicable aging effects would not have been addressed in the procedure. This event is

described in H.B. Robinson Steam Electric Plant - NRC Post-Approval Site Inspection for

License Renewal Inspection Report 05000261/2010008, dated April 7, 2010 (ADAMS

Accession No. ML100970495).

Additionally, NRC inspectors identified one example where the adequacy of an approved station

procedure, as part of an AMP to monitor water intrusion into manholes, which could lead to

age-related degradation in high- or medium-voltage cables for non-environmental qualification

applications, was not effectively verified prior to its final approval. The NRC inspectors noted

that the procedure to inspect manholes would not have provided adequate instructions, during

the period of extended operation, to fully meet the actions described in the UFSAR, due to

physical limitations in the manhole design. This event is described in Surry Power Station

Units 1 and 2 - NRC Post-Approval Site Inspection for License Renewal Inspection Report 05000280/2011010 and 05000281/2011010, dated September 12, 2011 (ADAMS Accession

No. ML112560062). It is important for licensees to: (1) establish implementation procedures that provide adequate

instructions for activities involving the testing, inspection, operation, or maintenance of systems, structures, and components within the scope of license renewal; and (2) ensure revisions to

procedures are controlled such that any changes to instructions that are incorporated to fulfill a

commitment for license renewal are given full consideration before being revised. By doing so, licensees can preclude the reduction in the effectiveness of AMPs and the unsatisfactory

completion of activities for license renewal. The licensees for H.B. Robinson and Surry

documented the deficiencies in their corrective action programs and initiated corrective actions

to address the issues.

Vermont Yankee Nuclear Power (Vermont Yankee) - Management of License Conditions

Added As Part of the Renewed License

During the license renewal application review, regulatory commitments are made by the

applicant and listed in Appendix A of the license renewal safety evaluation report. NRC

inspectors identified that commitments listed in Appendix A of the license renewal safety

evaluation report for Vermont Yankee had not been incorporated as part of the UFSAR

supplement. The conditions that were added as part of the renewed operating license for

Vermont Yankee did not require the commitments for license renewal to be incorporated as part

of the UFSAR. Furthermore, the specific wording of one of the license conditions that was

added to the renewed license stated, The UFSAR supplement, as revised, submitted pursuant

to 10 CFR 54.21(d), describes certain future activities to be completed prior to and/or during the

period of extended operation. [The licensee] shall complete these activities in accordance with

Appendix A of the safety evaluation report for license renewal. This wording escalated the

regulatory commitments to license conditions. Regulatory commitments that are incorporated

as part of the UFSAR supplement are considered components of the UFSAR, and are managed

in accordance with the requirements of 10 CFR 50.59. Regulatory commitments that are

referenced in the license condition for license renewal, but not incorporated as part of the

UFSAR, are to be treated as license conditions. Changes to license conditions require NRC

approval and are processed in accordance with the requirements of 10 CFR 50.90, Application

for amendment of license, construction permit, or early site permit. This issue appears in

Vermont Yankee Nuclear Power - NRC Inspection Report 05000271/2012008, dated April 20,

2012 (ADAMS Accession No. ML12103A406).

DISCUSSION

The renewed operating license requires that licensees update the UFSAR with the UFSAR

supplement, which includes programs and activities associated with license renewal. The

renewed license also requires that certain future activities be completed before the period of

extended operation. NRC inspectors conduct post-approval site inspections for license renewal

to verify that the licensee effectively implements and manages license conditions, AMPs, and

commitments for license renewal and to ensure that the licensee has made any necessary

corrections before the licensee enters the period of extended operation. This IN summarizes

several issues of concern that were identified during previous post-approval site inspections and

may have broad implications for plants scheduled for upcoming IP 71003 inspections.

Licensees manage changes to commitments and AMPs incorporated into the UFSAR

supplement in accordance with 10 CFR 50.59. Commitments that are not incorporated in the UFSAR, but are referenced in the license conditions for license renewal, are escalated to

license conditions. In accordance with 10 CFR 50.90, licensees can apply for amendments to

license conditions. Both the NRC and the licensees need to ensure that there is a clear

understanding of the intent and expectations with regard to the implementation of license

conditions and commitments for license renewal at the time the renewed license is issued.

A nonconformance with a commitment or AMP description included in the UFSAR could be a

deviation, whereas a nonconformance with a license condition could be a violation. Licensees

are required to correct deviations, deficiencies, and nonconformances in accordance with

Criterion XVI of Appendix B to 10 CFR Part 50, Corrective Action, or through their corrective

action programs.

CONTACT

S

This IN requires no specific action or written response. Please direct any questions about this

matter to the technical contacts listed below or the appropriate NRC project manager.

/RA/

Timothy J. McGinty, Director

Division of Policy and Rulemaking

Office of Nuclear Reactor Regulation

Technical Contacts: Stuart Sheldon, Region III Heather Jones, NRR

630-829-9727 301-415-4054 email: Stuart.Sheldon@nrc.gov email: Heather.Jones@nrc.gov

Note: You can find NRC generic communications on the NRCs public Web site, http://www.nrc.gov, under Electronic Reading Room/Document Collections.

ML12242A195 *concurred via email TAC ME9075 OFFICE RIII/DRS/EB2* NRR/DLR/RSRG* Tech Editor* RI/DRS/EB1/BC* RII//DRS/EB3/BC*

NAME SSheldon (AStone HJones JDougherty JTrapp SVias

for)

DATE 09/27/12 09/27/12 09/05/12 09/25/12 09/24/12 OFFICE RIII/DRS/EB2/BC* RIV/DRS/EB2/BC* NRR/DLR/RSRG/BC NRR/DORL/D NRR/DLR/D

NAME AStone GMiller YDiaz-Sanabria MEvans (LLund MGalloway

for)

DATE 09/27/12 09/24/12 09/28/12 10/09/12 10/16/12 OFFICE NRR/DPR/PGCB/PM NRR/DPR/PGCB/LA NRR/DPR/PGCB/BC NRR/DPR/D

NAME ARussell CHawes DPelton TMcGinty

DATE 10/18/12 10/18/12 10/22/12 10/23/12