MONTHYEARIR 05000331/20193012019-06-18018 June 2019 NRC Initial License Examination Report 05000331/2019301 ML22143A9352019-05-16016 May 2019 2019 DAEC Ile ES-201-1 ML22143A9382019-05-16016 May 2019 2019 DAEC Initial License Exam Form ES-201-3 ML22143A9392019-05-16016 May 2019 2019 DAEC Initial License Exam Form ES-301-7 ML22143A9412019-05-16016 May 2019 2019 DAEC Initial License Exam Form ES-401-4 ML22143A9422019-05-16016 May 2019 2019 DAEC Initial License Exam Form ES-401-9 ML22143A9432019-05-16016 May 2019 DAEC 2019 Outline Comments NG-19-0058, 2019 DAEC Addendum to Post Exam Submittal Letter-Comments on Q-70 Clarification2019-04-26026 April 2019 2019 DAEC Addendum to Post Exam Submittal Letter-Comments on Q-70 Clarification NG-19-0057, 2019 DAEC Initial License Examination Post Exam Submittal Letter2019-04-19019 April 2019 2019 DAEC Initial License Examination Post Exam Submittal Letter ML22143A9992019-04-0808 April 2019 2019 DAEC Ile Administered Admin JPMs ML22143B0002019-04-0808 April 2019 2019 DAEC Ile Administered Sim and Inplant JPMs ML22143B0012019-04-0808 April 2019 2019 DAEC Ile Scenarios ML22143B0022019-04-0808 April 2019 2019 Deac Ile Administered Written Exam ML22143B0032019-04-0808 April 2019 RO and SRO Exam Reference Handouts ML19087A3022019-03-28028 March 2019 Operator Licensing Examination Approval (Cdz) ML22144A0672019-02-22022 February 2019 2019 DAEC Ile Proposed RO and SRO Admin JPMs ML22144A0692019-02-22022 February 2019 2019 DAEC Ile Proposed Sim and Inplant JPMs ML22144A0712019-02-22022 February 2019 2019 DAEC Ile Proposed Scenarios ML22144A0732019-02-22022 February 2019 2019 DAEC Ile Proposed Written Exam ML22144A0742019-02-22022 February 2019 2019 DAEC Initial License Exam Form ES-301-3 ML22144A0752019-02-22022 February 2019 2019 DAEC Initial License Exam Form ES-301-4 ML22144A0762019-02-22022 February 2019 2019 Duane Arnold Initial License Exam Form ES-301-6 ML22144A0792019-02-22022 February 2019 2019 DAEC Initial License Exam Form ES-401-6 ML22145A4392019-01-23023 January 2019 2019 DAEC Initial License Examination Submittal Letter ML19009A2502019-01-0808 January 2019 GFE Annual Registration Letter - 2019 Examinations, Region III ML22143B0042018-12-21021 December 2018 2019 DAEC Ile ES-201-2 ML22143B0052018-12-21021 December 2018 2019 Duane Arnold Initial License Exam Forms ES-301-1 ML22143B0062018-12-21021 December 2018 2019 Duane Arnold Initial License Exam Forms ES-301-2 ML22143B0072018-12-21021 December 2018 2019 Duane Arnold Initial License Exam Forms ES-301-5 ML22143B0082018-12-21021 December 2018 2019 Duane Arnold Initial License Exam Forms ES-401-1 and 401-3 ML22143B0092018-12-21021 December 2018 2019 Duane Arnold Initial License Exam Forms ES-D1 ML22143B0102018-11-12012 November 2018 2019 DAEC Ile Outline Submittal Letter NG-18-0089, Preparation and Scheduling of Operator Licensing Examinations (Response to RIS 2018-02)2018-07-25025 July 2018 Preparation and Scheduling of Operator Licensing Examinations (Response to RIS 2018-02) ML18099A2622018-04-0909 April 2018 Gfes Results-March 2018, Duane Arnold Energy Center (Cover Letter Only) ML18086B0662018-03-27027 March 2018 Facility Cover Letter - Riii - March 2018 - GFE ML17361A0302017-12-26026 December 2017 GFE Annual Registration Letter - 2018 Examinations - Region III IR 05000331/20173012017-07-14014 July 2017 NRC Initial License Examination Report 05000331/2017301 (Meb) ML17214A0272017-06-14014 June 2017 Dua 2017 Ile - Proposed Exam ES-401-6 ML17214A0282017-06-14014 June 2017 Dua 2017 Ile - Proposed Exam Admin RO-SRO JPMs ML17214A0342017-06-14014 June 2017 Dua 2017 Ile - Proposed Exam Operating JPMs ML17214A0362017-06-14014 June 2017 Dua 2017 Ile - Proposed Exam Scenarios 1-2-3-Alt ML17214A0382017-06-14014 June 2017 Dua 2017 Ile - Proposed Exam RO Written Examination ML17214A0502017-06-14014 June 2017 Dua 2017 Ile - Proposed Exam SRO Written Examination ML17214A2142017-06-14014 June 2017 Dua 2017 Ile - Administered Exam Scenarios ML17214A2322017-06-14014 June 2017 Dua 2017 Ile - Administered Exam Operating Sim and IP JPMs ML17214A2592017-06-14014 June 2017 Dua 2017 Ile - Administered Exam RO-SRO Admin JPMs ML17214A2952017-06-14014 June 2017 Dua 2017 Ile - Administered Exam RO Written Examination ML17214A3072017-06-14014 June 2017 Dua 2017 Ile - Administered Exam SRO Written Examination ML17214A3502017-06-14014 June 2017 Dua 2017 Ile - Administered Exam Written Examination Handouts ML17214A4012017-06-14014 June 2017 Dua 2017 Ile Administrative Files ES-401-4 2019-06-18
[Table view] Category:Part 55 Examination Related Material
[Table view] Category:Letter
MONTHYEARL-2024-010, Point Units 3 and 4, Seabrook, Duane Arnold, and Point Beach Units 1 and 2, Nuclear Property Insurance - 10 CFR 50.54(w)(3)2024-01-25025 January 2024 Point Units 3 and 4, Seabrook, Duane Arnold, and Point Beach Units 1 and 2, Nuclear Property Insurance - 10 CFR 50.54(w)(3) NG-23-0010, Supplement to Duane Arnold Exemption Request Regarding Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Final Rule2023-12-0606 December 2023 Supplement to Duane Arnold Exemption Request Regarding Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Final Rule NG-23-0009, Part 73 Exemption Request Regarding Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Final Rule2023-11-16016 November 2023 Part 73 Exemption Request Regarding Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Final Rule ML23201A0872023-08-0303 August 2023 Audit Plan in Support of Review of License Amendment NG-23-0006, Independent Spent Fuel Storage Installation (ISFSI) Financial Assurance Update2023-05-23023 May 2023 Independent Spent Fuel Storage Installation (ISFSI) Financial Assurance Update ML23137A1672023-05-11011 May 2023 Submittal of 2022 Annual Radiological Environmental Operating Report NG-23-0004, 2022 Annual Radioactive Material Release Report2023-04-25025 April 2023 2022 Annual Radioactive Material Release Report NG-23-0003, 2022 Annual Exposure Report - Form 5s2023-04-21021 April 2023 2022 Annual Exposure Report - Form 5s NG-23-0002, 10 CFR 50.59 Report, Commitment Changes, 10 CFR 72.48 Report, Quality Assurance Program Changes, Technical Specification Basis Changes, and Revision of the DAEC Defueled Safety Analysis Report2023-03-27027 March 2023 10 CFR 50.59 Report, Commitment Changes, 10 CFR 72.48 Report, Quality Assurance Program Changes, Technical Specification Basis Changes, and Revision of the DAEC Defueled Safety Analysis Report NG-23-0001, 2023 Annual Decommissioning and Spent Fuel Management Funding Status Report2023-03-27027 March 2023 2023 Annual Decommissioning and Spent Fuel Management Funding Status Report L-2023-029, and Point Beach Units 1 and 2 Nuclear Property Insurance - 10 CFR 50.54(w)(3)2023-03-10010 March 2023 and Point Beach Units 1 and 2 Nuclear Property Insurance - 10 CFR 50.54(w)(3) ML22361A1022023-02-24024 February 2023 Reactor Decommissioning Branch Project Management Changes for Some Decommissioning Facilities and Establishment of Backup Project Manager for All Decommissioning Facilities ML22339A0012022-12-22022 December 2022 Acceptance of Requested Licensing Action Amendment Request for Common Emergency Plan IR 05000331/20220032022-12-13013 December 2022 NRC Inspection Report No. 05000331/2022003 (Drss) ML22285A0072022-10-13013 October 2022 NRC Analysis of NextEra Energy Duane Arnold'S Decommissioning Funding Status Report, Docket No. 50-331 IR 05000331/20220022022-07-13013 July 2022 NRC Inspection Report Nos. 05000331/2022002(DNMS) and 07200032/2022002(DNMS) ML22090A1922022-05-26026 May 2022 Letter to B. Coffey, FPL from M. Doell - Duane Arnold Post Shutdown Activities Report Review Letter ML22132A2872022-05-24024 May 2022 ISFSI DQAP Approval Letter ML22111A0332022-05-20020 May 2022 Operating License Page Correction Letter to B. Coffey, Florida Power and Light, from M. Doell NG-22-0055, Revision to Duane Arnold Energy Center (DAEC) ISFSI-Only Emergency Plan2022-05-20020 May 2022 Revision to Duane Arnold Energy Center (DAEC) ISFSI-Only Emergency Plan ML22089A0492022-05-12012 May 2022 Sfmp Review Letter NG-22-0053, 2021 Annual Radiological Environmental Operating Report2022-05-0606 May 2022 2021 Annual Radiological Environmental Operating Report NG-22-0052, Regulatory Issue Summary 2000-11. NRC Emergency Telecommunications System, Statement of Intent to Implement the Proposed Voluntary Initiative2022-05-0404 May 2022 Regulatory Issue Summary 2000-11. NRC Emergency Telecommunications System, Statement of Intent to Implement the Proposed Voluntary Initiative IR 05000331/20224012022-04-27027 April 2022 Decommissioning Security Inspection Report 05000331/2022401 NG-22-0050, Revised Response to Request for Additional Information Relating to Decommissioning Quality Assurance Program, Revision 02022-04-26026 April 2022 Revised Response to Request for Additional Information Relating to Decommissioning Quality Assurance Program, Revision 0 NG-22-0049, 2021 Annual Radioactive Material Release Report2022-04-26026 April 2022 2021 Annual Radioactive Material Release Report L-2022-068, NextEra Energy Duane Arnold Quality Assurance Topical Report (FPL-3) Revision 22022-04-25025 April 2022 NextEra Energy Duane Arnold Quality Assurance Topical Report (FPL-3) Revision 2 ML22066A7632022-04-25025 April 2022 ISFSI-Only Emergency Plan License Amendment Approval NG-22-0035, Response to Request for Additional Information Relating to Decommissioning Quality Assurance Program. Revision 02022-04-13013 April 2022 Response to Request for Additional Information Relating to Decommissioning Quality Assurance Program. Revision 0 NG-22-0047, Registration of Independent Spent Fuel Installation Storage Cask and Notification of Permanent Removal of All Spent Fuel Assemblies from the Spent Fuel Pool2022-04-11011 April 2022 Registration of Independent Spent Fuel Installation Storage Cask and Notification of Permanent Removal of All Spent Fuel Assemblies from the Spent Fuel Pool NG-22-0042, Registration of Independent Spent Fuel Installation Storage Casks2022-04-0808 April 2022 Registration of Independent Spent Fuel Installation Storage Casks NG-22-0041, and Independent Spent Fuel Storage Installation, 2022 Annual Decommissioning and Spent Fuel Management Funding Status Report2022-03-31031 March 2022 and Independent Spent Fuel Storage Installation, 2022 Annual Decommissioning and Spent Fuel Management Funding Status Report NG-22-0031, 2021 Annual Exposure Report - Form 5s2022-03-23023 March 2022 2021 Annual Exposure Report - Form 5s NG-22-0030, Registration of Independent Spent Fuel Installation Storage Casks2022-03-23023 March 2022 Registration of Independent Spent Fuel Installation Storage Casks ML22080A1822022-03-22022 March 2022 Letter to B. Coffey from M. Doell - Duane Arnold ISFSI QAPD RAI Letter L-2022-012, Florida Power & Light Company Nuclear Property Insurance - 10 CFR 50.54(w)(3)2022-03-16016 March 2022 Florida Power & Light Company Nuclear Property Insurance - 10 CFR 50.54(w)(3) ML22059A7462022-03-10010 March 2022 ISFSI-Only Physical Security Plan License Amendment Approval NG-22-0025, Registration of Independent Spent Fuel Installation Storage Casks2022-03-0808 March 2022 Registration of Independent Spent Fuel Installation Storage Casks IR 05000331/20220012022-03-0404 March 2022 Subject: NRC Inspection Report Nos. 05000331/2022001(DNMS) and 07200032/2022001(DNMS) NG-22-0021, Registration of Independent Spent Fuel Installation Storage Casks2022-02-24024 February 2022 Registration of Independent Spent Fuel Installation Storage Casks ML22007A2722022-02-11011 February 2022 Cover Letter - NRC Duane Arnold Exemption Issuance NG-22-0014, Registration of Independent Spent Fuel Installation Storage Casks2022-02-10010 February 2022 Registration of Independent Spent Fuel Installation Storage Casks ML22028A2822022-02-0303 February 2022 Defueled Physical Security Plan License Amendment Approval ML22033A0802022-02-0202 February 2022 Supplement to License Amendment Request (TSCR-188): Proposed Change to the Physical Security Plan for the Post-Shutdown and Permanently Defueled Condition IR 05000331/20210012022-01-25025 January 2022 NRC Inspection Report Nos. 05000331/2021001(DNMS); 07200032/2021001(DNMS); and 07200032/2021002(DNMS) - Duane Arnold Energy Center ML21172A2172022-01-21021 January 2022 Issuance of License Amendment to Adopt ISFSI-Only Technical Specifications NG-22-0009, Registration of Independent Spent Fuel Installation Storage Casks2022-01-20020 January 2022 Registration of Independent Spent Fuel Installation Storage Casks NG-22-0001, Supplement to Exemption Request for Failed Fuel Can Weight in a Certificate of Compliance 1004 Renewed Amendment 17 61BTH Type 2 Dry Shielded Canister2022-01-0606 January 2022 Supplement to Exemption Request for Failed Fuel Can Weight in a Certificate of Compliance 1004 Renewed Amendment 17 61BTH Type 2 Dry Shielded Canister NG-21-0038, Registration of Independent Spent Fuel Installation Storage Casks2021-12-22022 December 2021 Registration of Independent Spent Fuel Installation Storage Casks NG-21-0035, Supplement to Exemption Request for Failed Fuel Can Weight in a Certificate of Compliance 1004 Renewed Amendment 17 61 Bth Type 2 Dry Shielded Canister2021-12-10010 December 2021 Supplement to Exemption Request for Failed Fuel Can Weight in a Certificate of Compliance 1004 Renewed Amendment 17 61 Bth Type 2 Dry Shielded Canister 2024-01-25
[Table view] |
Text
2011 DUANE ARNOLD ENERGY CENTER INITIAL EXAMINATION PROPOSED EXAM FILES
NEXTera" ENERGV~
/ DUANE ARNOLD May 11,2011 NG-11-0171 NUREG 1021 u.s. Nuclear Regulatory Commission, Region III Attention: Chuck Zoia 2443 Warrenville Road Suite 210 Lisle, IL 60532-4352 Duane Arnold Energy Center Docket 50-331 License No. DPR-49 Examination Material for Duane Arnold Energy Center Initial License Examination Week of June 27,2011 In accordance with the guidelines of NUREG 1021, "Operating License Examination Standard for Power Reactors," Revision 9, we are sending you the written examination portion of the initial license examinations to be administered at our facility the week of June 27,2011.
NUREG 1021 physical security requirements state that the enclosed examination materials shall be withheld from public disclosure until after the examination is complete.
You may direct any questions or comments regarding this material to Curtis Hansen or Wayne Render at 319-851-7268.
This letter contains no new commitments.
Christopher R. Costanzo Vice President, Duane Arnold Energy Center NextEra Energy Duane Arnold, LLC Enclosure CC: Chief Operator License Branch, Region III NRC Resident Inspector NRC Document Control Desk NextEra Energy Duane Arnold, LLC, 3277 DAEC Road, Palo, IA 52324
BLIND CARBON COPY LIST FOR NG-11-0171 May 11, 2011 D. Curtland w/o G. Pry w/o C. Hansen w/o W. Render w/o IRMS w/o S. Catron w/o W. Simmons w/o Licensing CTS Project w/o
SUBJECT:
Examination Material for Duane Arnold Energy Center Initial License Examination Week of June 27.2011 FILE CODES: A117a
ES-301 Operating Test Quality Checklist Form ES-301-3
a.
DAEC Date of Examination:
- 1. GENERAL CRITERIA 6/2011 Operating Test Number:
The operating test conforms with the previously approved outline; changes are consistent a
Initials b*
2011 . , II elf.
with sampling requirements (e.g. 10 CFR 55.45, operational importance, safety function distribution). ~ ~ ~ '!'>
- b. There is no day-to-day repetition between this and other operating tests to be administered during this examination. Q)Ji 1,v IQI? .
- c. The operating test shall not duplicate items from the applicants' audit testes) (see Section D.1.a). ~ .Jt, f!,I/If Overlap with the written examination and between different parts of the operating test is
~ .tv d.
within acceptable limits.
CMf*
~ .J../
- e. It appears that the operating test will differentiate between competent and less-than selevel. ~
- 2. WALK-THROUGH CRITERIA - - -
- a. Each JPM includes the following, as applicable:
. initial conditions initiating cues references and tools, including associated procedures
~
- reasonable and validated time limits (average time allowed for completion) and specific designation if deemed to be time-critical by the facility licensee
'" operationally important specific performance criteria that include:
- detailed expected actions with exact criteria and nomenclature
~
- system response and other examiner cues ./)..I
- statements describing important observations to be made by the applicant
- criteria for successful completion of the task
- identification of critical steps and their associated performance standards
- restrictions on the sequence of steps, if applicable
- b. Ensure that any changes from the previously approved systems and administrative walk
~
through outlines (Forms ES-301-1 and 2) have not caused the test to deviate from any of the acceptance criteria (e.g., item distribution, bank use, repetition from the last 2 NRC )/v ~
examinations) specified on those forms and Form ES-201-2.
- 3. SIMULATOR CRITERIA - - -
The associated simulator operating tests (scenario sets) have been reviewed in accordance with Form ES-301-4 and a copy is attached. ~ .w hNf Printed N a t Signature Date
- a. Author Curtis Hansen I /Jpj::b. './~ S!tz-!t(
- b. Facility Reviewer (*) Glenn Rushworth I ~~ <;lIz/II
- c. NRC Chief Examiner (#) ()huk ~/a /£~J..L W~ (P/I/' , 'K I?
ih 'J2..//).,,,,. f \Eb'L. ,""S:IJ~ r,/AfJ/t,
~
- d. NRC Supervisor .db. ,A, A
"~/T y
/
c NOTE:
- The facility signature is not applicable for NRC-developed tests.
- Independent NRC reviewer initial items in Column "COO; chief examiner concurrence required.
ES-301 Simulator Scenario Quality Checklist Form ES-301-4
- FacUit : DAEC Date of Exam: 6/2011 Scenario Numbers: 1 I 2 13 14 QUALITATIVE ATTRIBUTES o
- 1. The initial conditions are realistic, in that some equipment and/or instrumentation may be out of service, but it does not cue the operators into expected events.
- 2. The scenarios consist moslly of related events.
- 3. Each event description consists of
- the point in the scenario when it is to be initiated
- the malfunction(s) that are entered to initiate the event
- the symptoms/cues that will be visible to the crew
- the expected operator actions (by shift position)
- the event termination point (if applicable)
- 4. No more than one non-mechanistic failure (e.g., pipe break) is incorporated into the scenario without a credible preceding incident such as a seismic event.
- 5. The events are valid with regard to physics and thermodynamics.
- 6. Sequencing and timing of events is reasonable, and allows the examination team to obtain complete evaluation results commensurate with the scenario objectives.
- 7. If time compression techniques are used, the scenario summary clearly so indicates.
Operators have sufficient time to carry out expected activities without undue time constraints.
Cues are given.
- 8. The simulator modeling is not altered.
- 9. The scenarios have been validated. Pursuant to 10 CFR 55.46(d), any open simulator performance deficiencies or deviations from the referenced plant have been evaluated to ensure that functional fidelity is maintained while running the planned scenarios.
- 10. Every operator will be evaluated using at least one new or significantly modified scenario.
All other scenarios have been altered in accordance with Section 0.5 of ES-301.
- 11. All individual operator competencies can be evaluated, as verified using Form ES-301-6 (submit the form along with the simulator scenarios).
- 12. Each applicant will be significanlly inVOlved in the minimum number of transients and events specified on Form ES-301-5 (submit the form with the simulator scenarios).
- 13. The level of difficulty is appropriate to support licensing decisions for each crew position.
Target Quantitative Attributes (Per Scenario; See Section D.S.d) Actual Attributes 1 121 3 I 4
- 1. Total malfunctions (5-8) 7 7 7 8
- 2. Malfunctions after EOP entry (1-2) 2 2 2
- 3. Abnormal events (2-4) 2 3 3 2
- 4. Major transients (1-2)
- 5. EOPs entered/requiring substantive actions (1-2) 2 2 2 2
- 6. EOP contingencies requiring substantive actions (0-2) 0
- 7. Critical tasks (2-3) 3 3 1 2 2
ES-301 Competencies Checklist Form ES-301-6
- Facility: DAEC Date of Examination:
RO SRO-I 0
[8J 6/2011 RO SRO-I 0 Operating Test No.:
APPLICANTS 0 RO SRO-I
[8J 0
2011 NRC SRO-U 0 SRO-U [8J SRO-U 0 Competencies SCENARIO SCENARIO SCENARIO 1 2 3 4 1 2 3 4 1 2 3 4 Interpret/Diagnose 3*7 2*7 3*8 2,4*9 3*7 2*7 3*8 2,4-9 3*7 2*7 3*8 2,4-9 Events and Conditions Comply With and Use ALL ALL ALL ALL ALL ALL ALL ALL ALL ALL ALL NA Procedures (1)
Operate Control Boards NA NA NA NA NA NA NA NA ALL ALL ALL NA i (2)
Communicate and ALL ALL ALL ALL ALL ALL ALL ALL ALL ALL ALL NA I Interact Demonstrate Supervisory ALL ALL ALL ALL ALL ALL ALL ALL NA NA NA NA i Ability (3)
Comply With and Use 3,5 2,4 4,5 2,4,6 I 3,5 2,4 4,5 2,4,6 NA NA NA NA Tech. Specs. (3)
Notes:
(1 ) Includes Technical Specification compliance for an RO.
(2) Optional for an SRO-U.
(3) Only applicable to SROs.
Instructions:
Circle the applicants' license type and enter one or more event numbers that will allow the examiners to evaluate every applicable competency for every applicant.
ES-401 Written Examination Quality Checklist Form ES-401-6
- Duane Arnold Item Description Date of Exam: 6/2011 Exam Level: RO iii SRO iii a
Initial b* ell 1~1.,- .-:Q=.:u: . : e:.: s: :.:.tio: .:.-n: :.s-=a~nd=-=anc.:.:s:.:. :w:.: e:.: rs:. .:te: ;.:ch: :. :.:. :.nI:.: .*ca: .:U:.Lly...:::a:::.cc:::;u:.:..:ra::..::te::...=;sn:.:..:d:....:a::c1p=pllica=bl:;:.e...:.:to:...:f:.::.a.:;:ci.:.:,:lityL.:.._ _ _ _--I~)ji)A~._+..IA::.Ioa'I"";~'--t-_Cht,+--II~.rt>*
- 2. a. NRC KlAs referenced for all questions. r> v!
- b. Facility learning objectives referenced as available.
1~~~~~~~==~~~~==~-----------+~n~~~~~~._~~~~~L~*
~. . -tt..... on, ?~ 'If
- 3. SRO questions are appropriate in accordance with Section D.2.d of ES-401 .jl.ItI"O --1A.. '-'Vj ~
- 4. The sampling process was random and systematic. (If more than 4 RO and 2 SRO A Mlk questions were repeated from the last 2 NRC licensing exams, consult the NRR OL Jr' /,
Program Office) ...N\/
- 5. Question duplication from the license screening/audit exam was controlled as indicated below (check the item that applies) and appears appropriate:
X the audit exam was systematically and randomly developed, or
__ the audit exam was completed before the license exam was started, or
__ the examinations were developed independently, or
__ the licensee certifies that there is no duplication, or
_ other (explain)
- 6. Bank use meets limits (no more than 75 percent Bank I Modified New
~ ~
from the bank at least 10 percent new, and the rest new or modified); enter the actual ROJ SRO-only 32/9 I % 43/16
~uestion distribution(s) at right.
- 7. Between 50 and 60 percent of the question on the MemoiY CIA RO exam are written at the comprehension!
analysis level; the SRO exam may exceed 60 33/6 42/19 ')t percent if the randomly selected KlAs support the '):'.L'?
higher cognitive levels; enter the actual RO I SRO . ~
question distribution(s) at right !
- 8. References/handouts provided do not give away answers or aid in the elimination of distractors. ~ ~*
- 9. Question content conforms with specific KIA statements in the previously approved examination outline and is appropriate for the tier to which they are assigned; deviations are justified. ~ ~~~ *'
- 10. Question psychometric quality and format meet the guidelines in ES Appendix B.
COvJ 1;~ *
- 11. The exam contains the required number of one-point, multiple choice items; the Ie~
total is correct and agrees with value on cover sheet. O.¥>vf Printed Name I Signature Date
- a. Author Curtis Hansen I jJt?~~ 511212011
- b. Facility Reviewer (...) Glenn Rushworth 1 /L~ ~ 5/1212011 v ~ -----lI1!.~l)1I"l 6'IWt1.()t
- c. NRC Chief Examiner (#) C ~ctrle5 1), ~,q I -Og .o.."D, I~ /' ~/zajtOIl ~~~
- d. NRC Regional Superviso~ /lrvt'J'ftJY"; Pi~ ~ ~ / / IPI/II -; b/~clll 1r-____________xq ____________~ ____v______ v ____________________~lf~~~~~~
Note: * (N1f'1CATII>~
The facility reviewer's initials/signature are not applicable for NRC-developed examinations.
- Independent NRC reviewer initial items in Column "c"; chief examiner concurrence required .
NUREG-1021, Revision 9, Supplement 1