ML22143B005

From kanterella
Jump to navigation Jump to search
2019 Duane Arnold Initial License Exam Forms ES-301-1
ML22143B005
Person / Time
Site: Duane Arnold 
Issue date: 12/21/2018
From: Randy Baker
NRC/RGN-III/DRS/OLB
To:
Baker R
Shared Package
L17214A864 List:
References
Download: ML22143B005 (2)


Text

ES-301 Administrative Topics Outline Form ES-301-1 Facility:

DAEC Date of Examination:

4/8/19 Examination Level: RO SRO Operating Test Number:

19-1 NRC Administrative Topic (see Note)

Type Code*

Describe activity to be performed Conduct of Operations S, R, D 2.1.4 Knowledge of individual licensed operator responsibilities related to shift staffing, such as medical requirements, no-solo operation, maintenance of active license status, 10CFR55, etc. (CFR: 41.10 / 43.2)

IMPORTANCE RO 3.3 SRO 3.8 2.1.4-01 Operator License Status Verification Conduct of Operations S, D, P 2.1.31 Ability to locate control room switches, controls, and indications, and to determine that they correctly reflect the desired plant lineup.

(CFR: 41.10 / 45.12)

IMPORTANCE RO 4.6 SRO 4.3 Perform the RHR Control Panel Lineup Equipment Control S, D 2.2.12 Knowledge of surveillance procedures (CFR: 41.10 / 45.13)

IMPORTANCE RO 3.7 SRO 4.1 2.2.12-03, Perform STP 3.4.2-01, DAILY JET PUMP OPERABILITY TEST [determine that Multiple jet pumps are out of spec]

Radiation Control N/A Emergency Plan S, N 2.4.25 Knowledge of fire protection procedures (CFR: 41.10 / 43.5 / 45.13)

IMPORTANCE RO 3.3 SRO 3.7 Respond to a Fire Alarm and activate the fire brigade NOTE: All items (five total) are required for SROs. RO applicants require only four items unless they are retaking only the administrative topics (which would require all five items).

  • Type Codes and Criteria:

(C)ontrol room, (S)imulator, or Class(R)oom (D)irect from bank ( 3 for ROs; 4 for SROs and RO retakes)

(N)ew or (M)odified from bank ( 1)

(P)revious 2 exams ( 1, randomly selected)

ES-301 Administrative Topics Outline Form ES-301-1 Facility:

DAEC Date of Examination:

4/8/2019 Examination Level: RO SRO Operating Test Number:

19-1 NRC Administrative Topic (see Note)

Type Code*

Describe activity to be performed Conduct of Operations S, R, N 2.1.4 Knowledge of individual licensed operator responsibilities related to shift staffing, such as medical requirements, no-solo operation, maintenance of active license status, 10CFR55, etc.

IMPORTANCE RO 3.3 SRO 3.8 SRO - NRC License Maintenance Responsibilities Conduct of Operations S, R, D 2.1.18 Ability to make accurate, clear, and concise logs, records, status boards, and reports.

IMPORTANCE RO 3.6 SRO 3.8 2.1.18-02, Determine Reportability - Unusual Event and Plant Shutdown Required by T.S.

Equipment Control S, R, D, P 2 2.2.19 Knowledge of maintenance work order requirements IMPORTANCE RO 2.3 SRO 3.4 2.2.19-01, Review a Work Order for closure Radiation Control S, R, N 2.3.5 Ability to use radiation monitoring systems, such as fixed radiation monitors and alarms, portable survey instruments, personnel monitoring equipment, etc.

(CFR: 41.11 / 41.12 / 43.4 / 45.9)

IMPORTANCE RO 2.9 SRO 2.9 2.3.5-##, Complete PASAP 7.2, Fuel Damage Assessment Emergency Plan S, D 2.4.41 Knowledge of the emergency action level thresholds and classifications.

IMPORTANCE RO 2.9 SRO 4.6 2.4.41-18, Declare an Emergency Action Level and fill out Note 5 in preparation for notification of Linn, Benton and State NOTE: All items (five total) are required for SROs. RO applicants require only four items unless they are retaking only the administrative topics (which would require all five items).

  • Type Codes and Criteria:

(C)ontrol room, (S)imulator, or Class(R)oom (D)irect from bank ( 3 for ROs; 4 for SROs and RO retakes)

(N)ew or (M)odified from bank ( 1)

(P)revious 2 exams ( 1, randomly selected)