UNITED STATES

NU C LE AR RE G UL AT O RY C O M M I S S I O N

R E GI ON I V

612 EAST LAMAR BLVD , SU I TE 400

AR LI N GTON , TEXAS 76011-4125

February 7, 2011

Michael Perito

Site Vice President

Entergy Operations, Inc.

River Bend Station

5485 US Highway 61N

St. Francisville, LA 70775

SUBJECT: RIVER BEND STATION - NRC INTEGRATED INSPECTION REPORT

05000458/2011002

Dear Mr. Perito:

The purpose of this letter is to notify you that the U.S. Nuclear Regulatory Commission (NRC)

Region IV staff will conduct a triennial heat sink inspection at your facility. The inspection will be

comprised of one reactor inspector from the NRC Region IV office. The inspection will be

conducted in accordance with Inspection Procedure 71111.07T, "Heat Sink Performance."

The schedule for the inspection is as follows: onsite inspection: March 14-18, 2011

Experience has shown that this inspection is resource intensive both for the NRC inspectors

and your staff. In order to minimize the impact to your onsite resources and to ensure a

productive inspection, we have enclosed a request for documents needed for this inspection.

Please note that the documents are requested to be provided by March 4, 2011. We request,

that during the onsite inspection week, you ensure that copies of analyses, evaluations, or

documentation regarding the implementation and maintenance of your heat exchanger program

are available. Of specific interest are those documents that establish that your heat exchanger

program satisfies NRC regulatory requirements and conforms to applicable NRC guidance.

Also, appropriate personnel knowledgeable of safety-related heat exchangers should be

available to support the inspector at the site during the inspection.

We have discussed the schedule for this inspection activity with your staff and understand that

our regulatory contact for this inspection will be Ms. Kristi Huffstatler of your licensing

organization. If there are any questions about this inspection or the material requested, please

contact the lead inspector, Ronald A. Kopriva, at 817-860-8104 or by email,

ron.kopriva@nrc.gov . In accordance with 10 CFR 2.390 of the NRCs Rules of Practice, a

copy of this letter and its enclosure will be available electronically for public inspection in the

NRC Public Document Room or from the Publicly Available Records (PARS) component of

NRC's document system (ADAMS). ADAMS is accessible from the NRC Web site at

http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).

Entergy Operations, Inc. -2-

Sincerely,

/RA/

Thomas R. Farnholtz, Chief

Engineering Branch 1

Division of Reactor Safety

Docket: 50-458

License: NPF-47

Enclosure: Heat Exchanger/Heat Sink

Inspection Documentation Request

cc w/enclosure:

Senior Vice President and COO

Entergy Operations, Inc

P. O. Box 31995

Jackson, MS 39286-1995

Vice President, Oversight

Entergy Operations, Inc.

P. O. Box 31995

Jackson, MS 39286-1995

Senior Manager, Nuclear Safety & Licensing

Entergy Nuclear Operations

P. O. Box 31995

Jackson, MS 39286-1995

Manager, Licensing

Entergy Operations, Inc.

5485 US Highway 61N

St. Francisville, LA 70775

Attorney General

State of Louisiana

P. O. Box 94005

Baton Rouge, LA 70804-9005

Ms. H. Anne Plettinger

3456 Villa Rose Drive

Baton Rouge, LA 70806

Entergy Operations, Inc. -3-

President of West Feliciana

Police Jury

P. O. Box 1921

St. Francisville, LA 70775

Mr. Brian Almon

Public Utility Commission

William B. Travis Building

P. O. Box 13326

Austin, TX 78701-3326

Mr. Jim Calloway

Public Utility

Commission of Texas

1701 N. Congress Avenue

Austin, TX 78711-3326

Louisiana Department of Environmental Quality

Radiological Emergency Planning and

Response Division

P. O. Box 4312

Baton Rouge, LA 70821-4312

Joseph A. Aluise

Associate General Counsel - Nuclear

Entergy Services, Inc.

639 Loyola Avenue

New Orleans, LA 70113

Chief, Technological Hazards

Branch

FEMA Region VI

800 N. Loop 288

Denton, TX 76209-3606

Entergy Operations, Inc. -4-

Electronic distribution by RIV:

Regional Administrator (Elmo.Collins@nrc.gov )

Deputy Regional Administrator (Art.Howell@nrc.gov )

DRP Director (Kriss.Kennedy@nrc.gov )

DRP Deputy Director (Troy.Pruett@nrc.gov )

DRS Director (Anton.Vegel@nrc.gov )

DRS Deputy Director (Vacant)

Senior Resident Inspector (Grant.Larkin@nrc.gov )

Branch Chief, DRP/C (Vincent.Gaddy@nrc.gov )

RBS Administrative Assistant (Lisa.Day@nrc.gov )

Senior Project Engineer, DRP/C (Bob.Hagar@nrc.gov )

Project Engineer, DRP/C (Rayomand.Kumana@nrc.gov )

Public Affairs Officer (Victor.Dricks@nrc.gov)

Public Affairs Officer (Lara.Uselding@nrc.gov )

Project Manager (Alan.Wang@nrc.gov )

Branch Chief, DRS/TSB (Michael.Hay@nrc.gov )

RITS Coordinator (Marisa.Herrera@nrc.gov )

Regional Counsel (Karla.Fuller@nrc.gov )

Congressional Affairs Officer (Jenny.Weil@nrc.gov )

OEMail Resource

Inspection Reports/MidCycle and EOC Letters to the following:

ROPreports

Only inspection reports to the following:

OEDO RIV Coordinator (James.Trapp@nrc.gov )

DRS/TSB STA (Dale.Powers@nrc.gov )

File located: ML110380088

SUNSI Rev Compl. X Yes No ADAMS X Yes No Reviewer Initials

Publicly Avail X Yes No Sensitive Yes X No Sens. Type Initials

RIV: DRS/EB1/SRI C: EB1

R. Kopriva TFarnholtz

/RA/ /RA/

01/06/11 01/07/11

OFFICIAL RECORD COPY T=Telephone E=E-mail F=Fax

ENCLOSURE

Heat Exchanger/Heat Sink Inspection Documentation Request

The following heat exchangers/heat sinks have been selected for inspection:

Please provide the following documentation prior to the onsite inspection week, preferably no

later than March 4, 2011.

Test Documents

Copies of the last two heat exchanger tests for the selected heat exchangers (original test data

in work orders or filled in test procedures) and copies of condition reports associated with the

heat exchanger testing

List of condition reports, with descriptions, associated with heat exchanger testing for the past 3

years (all safety-related heat exchangers)

Copies of applicable heat exchanger test procedures for the selected heat exchangers,

including test conditions and acceptance criteria

Copies of chemistry control procedures and results of chemistry sampling and a list of condition

reports concerning service water chemistry problems for the past 3 years

Documents that show the as-found results are recorded, evaluated, and appropriately

dispositioned such that the as-left condition is acceptable

Cleaning Documents

Copies of the last two heat exchanger cleaning results for the selected heat exchangers, original

data (found in filled test procedures or work orders) and condition reports associated with heat

exchanger cleaning

Cleaning procedures with acceptance criteria for the selected heat exchangers

List of condition reports, with descriptions, associated with heat exchanger cleaning for the past

3 years (all safety-related heat exchangers)

Show that as-found results are recorded, evaluated, and appropriately dispositioned such that

the as-left condition is acceptable

-1- Enclosure

Design Documents

Copies of vendor data sheets and design basis data for the selected heat exchangers

The design margin of the heat exchangers (the maximum heat transfer rate achievable at

design basis conditions compared to the vendors design heat transfer rate)

Copies of calculations which show the heat exchangers will meet their design basis

requirements under worst case conditions. Calculation for the maximum allowable number of

tubes plugged and how many tubes are currently plugged

For room coolers, calculations of the maximum room temperature under accident conditions and

determination that the coolers can maintain less than the maximum temperature under design

conditions

Documents that show that the heat exchangers have been evaluated for potential water

hammer

Instrument uncertainties of the instruments used during testing

Corrective action reports concerning cavitation noise in any heat exchanger system

The most recent audit report of heat exchanger testing and cleaning

The most recent service water flow balance test results, both as-found and as-left

Corrective Action Documents

List of corrective action documents, with descriptions, for the past 3 years for all

safety-related heat exchangers

Inspector Contact Information:

Ronald A. Kopriva

Senior Reactor Inspector

817-860-8104

Ron.kopriva@nrc.gov.

Mailing Address:

US NRC Region IV

Attn: Ron Kopriva

612 East Lamar Blvd., Suite 400

Arlington, TX 76011-4125

-2- Enclosure